1 Akzo Nobel Industrial Coatings AB Staffanstorpsvägen 50, Sege SE Malmö Order no. Page Appendices of 1 Test Report Material: The system under test is 2 x Aqua Combi WA D20. The test specimens were treated at Akzo Nobel Industrial Coatings AB on with primer Aqua Combi WA D20 and topcoat Aqua Combi WA D20 under supervision of Elisabeth Morsing and Heidi Herup, Danish Technological Institute. The formulation is not disclosed. Method: EN 152-1: "Wood preservatives - Laboratory method for determining the protective effectiveness of a preservative treatment against blue stain in service. Part 1: Brushing procedure". Modification: Weathering was carried out by QUV according to cycle 1 in the revision of EN 152, CEN TC 38 WG 23 N 107 on 17 th March See the enclosed report no. 196/07 from Centre for Plastics Technology dated (Appendix 3). Result: Treatment Blue stain on surface (Average) Smallest depth of blue stain-free zone () * Mean depth of blue stain-free zone () * Tested system Reference without fungicide Untreated control, with Untreated control, without * Rounded off to Appendices: Note: Storage: Terms: Appendix 1. Surface treatment and. (1 page). Appendix 2. Detailed results of treatment and biological assessment. (3 pages). Appendix 3. Report from Centre for Plastics Technology. (2 pages). The interpretation of this test report and the practical conclusions that can be drawn from it require a basic knowledge of the problems of wood preservation. For this reason this test report alone does not indicate any official approval of the wood preservative tested. The samples will be destroyed after 6 months, if nothing else has been agreed in writing. The test has been performed according to the rear side conditions, which are according to the guidelines laid down by DANAK (The Danish Accreditation). The testing is only valid for the tested specimen. The test report may only be extracted, if the laboratory has approved the extract , Danish Technological Institute, Timber, Taastrup Elisabeth Morsing \\dmwclus\dmw_docs\ \ _report, EN 152-1, treatment 3, Akzo 2007.doc Heidi Herup
2 Appendix 1. Surface treatment and. EN Wood preservatives - Laboratory method for determining the protective effectiveness of a preservative treatment against blue stain in service. Part 1: Brushing Procedure. Assignor: Akzo Nobel Industrial Coatings AB Staffanstorpsvägen 50, Sege SE Malmö System under test: 2 x Aqua Combi WA D20. Surface Treatment, System under test: Primer: Aqua Combi WA D20 - Spray application The directions of the assignor for wet film: µm corresponding to g/m². Topcoat: Aqua Combi WA D20 - Spray application The directions of the assignor for wet film: µm corresponding to g/m². Surface Treatment, Reference without fungicide: Primer: reference without fungicide - Spray application. The directions of the assignor for wet film: µm corresponding to g/m². Topcoat: Aqua Combi WA D20- Spray application The directions of the assignor for wet film: µm corresponding to g/m². Wood Species: Scotch pine, sapwood (Pinus sylvestris L.) Period: The testing was carried out from to Weathering: QUV was carried out from to Incubation: 6 weeks at 21 C / 70 % RH from to Evaluation Date: No. of Replica: 6 Sterilisation: Ionising radiation (2 x 50 kgy) Test Fungi: Aureobasidium pullulans, P 268 Sydowia pithyophilia, S 231. \\dmwclus\dmw_docs\ \ _report, EN 152-1, treatment 3, Akzo 2007.doc Page 1 of 1
3 Appendix 2. Detailed results of treatment and biological assessment. Treatment of test specimens Primer Topcoat Tested system Aqua Combi WA D20 Aqua Combi WA D20 Applied amount Applied amount g g/m² g g/m² Average Min Max Ref. without Primer Topcoat fungicide Aqua Combi WA D20 Applied amount Applied amount g g/m² g g/m² Average Min Max \\dmwclus\dmw_docs\ \ _report, EN 152-1, treatment 3, Akzo 2007.doc Page 1 of 1
4 Appendix 2. Detailed results of treatment and biological assessment. Biological Assessment surface for blue stain. inhibition zone on cross section Tested system Average Min Max Average Min Max Reference without surface for blue stain. inhibition zone on cross section fungicide Average Min Max Average Min Max \\dmwclus\dmw_docs\ \ _report, EN 152-1, treatment 3, Akzo 2007.doc Page 2 of 2
5 Appendix 2. Detailed results of treatment and biological assessment. Untreated control, with surface for blue stain. inhibition zone on cross section Average Min Max Average Min Max Untreated control, without surface for blue stain. inhibition zone on cross section Average Min Max Average Min Max \\dmwclus\dmw_docs\ \ _report, EN 152-1, treatment 3, Akzo 2007.doc Page 3 of 3
6
7
Basis for Assessment of Wood Preservatives
SKH PUBLICATION 06-04 dd. 15-11-2010 Basis for Assessment of Wood Preservatives Published by: SKH Copyright reserved Publisher: Certification-body SKH Advisory Committee Wood Preservation (ACWP) Nieuwe
More informationMARTIN TESTING LABORATORIES (MTL) PAINTS AND COATINGS TESTING CAPABILITIES
Liquid Coating Properties Composition VOC Content, ASTM D2369 Water Content, ASTM D4017 Physical Properties Calculating Physical Constants of Coatings, ASTM D5201 Density, ASTM D1475 Flash Point, ASTM
More informationDurability of acetylated Radiata Pine investigation of the resistance against brown-, white- and soft rot fungi
Title: Durability of acetylated Radiata Pine investigation of the resistance against brown-, Report code: 6.244-3 Date: 20 April 2007 Report code: 6.244-3 Date: 20 April 2007 Page: 2/16 SHR Timber Research
More informationTried, Tested and Proven Timber Protection
November 05 A Choice of Treatments SPECIFIER S GUIDE Tried, Tested and Proven Timber Protection Preservative and fire retardant industrial treatments to help make the most of timber. Tried, Tested and
More informationTest report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA 18000 / Israel. J. Magner Dipl.-Ing. N. Machill.
Kiwa Polymer Institut GmbH Quellenstraße 3 65439 Flörsheim-Wicker Tel. +49 (0)61 45-5 97 10 Fax +49 (0)61 45-5 97 19 www.kiwa.de Test report P 7013-E Testing order: Test of the waterproofing system based
More informationTimber Decks. Technical Note. March 2007
Timber Decks Technical Note. March 2007 This Technical Note contains general information for residential timber decks and floor frame structures for veranda s, patios etc which are exposed to the weather.
More informationApplication of Exterior Wood Finishes
Application of Exterior Wood Finishes The following information is excerpted from the publication, Exterior Wood in the South Selection, Applications, and Finishes by Daniel L. Cassens and William C. Feist;
More informationNATURAL DURABILITY OF DIFFERENT WOOD SPECIES RESULTS AFTER FIVE YEARS TESTING IN GROUND CONTACT
NATURAL DURABILITY OF DIFFERENT WOOD SPECIES RESULTS AFTER FIVE YEARS TESTING IN GROUND CONTACT Flæte, P.O. 1, Evans, F.G. 2 & Alfredsen, G. 3 ABSTRACT Information given in EN 350-2 on natural durability
More informationWood Projects Outdoors. Post Hole Specifications. Deck Span Tables. www.jon Eakes.com
Wood Projects Outdoors Post Hole Specifications & Deck Span Tables www.jon Eakes.com Building Fences The depth of the fence posts into the ground must be at least one foot below the frost level for your
More informationBS 476: Part 7: 1997. Method For Classification Of The Surface Spread Of Flame Of Products. A Report To: Eco-Sol Ltd. Document Reference: 304043
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS 476: Part 7: 1997 Method For Classification
More informationEUROTUBO DELTALAB 6. SWABS
92 93 94 The swab, sterile or non sterile, is used for biological sample collection. Specially used for processing samples which, after being coloured, will be analysed by microscopy. Also suitable for
More informationNordic requirements for quality control of preservativetreated
Nordic requirements for quality control of preservativetreated wood Part 1: Pine and other permeable softwoods NWPC Document No 3:2013 Nordic Wood Preservation Council 2012 2 NWPC Document No 3:2013 Nordic
More informationTIGER Drylac U.S.A., Inc. 3855 Swenson Avenue St Charles, IL T 800 243 8148 F 877 926 8148 office.us@tiger-coatings.us www.tiger-coatings.
Product Data Sheet SERIES 69 - DRYZINC ZINC-RICH PRIMER (69/90500) Epoxy zinc-rich powder coating primer. Part of a two-coat TIGER Shield system. Designed to impart superior corrosion protection to steel
More information10P20-44 High Solids Epoxy Primer
Technical Data Sheet Product Group High solids epoxy primer Characteristics Product Information A high solids urethane compatible, Skydrol resistant primer for the exterior of aircraft. It provides excellent
More informationEclipse. Technical Data Sheet. Polyurethane topcoat. Product Group
Technical Data Sheet Product Group Polyurethane topcoat Characteristics Product Information A chemically cured, low VOC topcoat designed to provide premium gloss and distinctness of image (DOI). This coating
More informationProperties of thermally modified wood
Properties of thermally modified wood All the properties described are based on the results of a range of tests, conducted over a period of several years by VTT, the Helsinki University of Technology and
More informationDETERMINATION OF WOOD MOISTURE PROPERTIES USING CT- SCANNER IN A CONTROLLED ENVIRONMENT
DETERMINATION OF WOOD MOISTURE PROPERTIES USING CT- SCANNER IN A CONTROLLED ENVIRONMENT Cherepanova, E. 1 & Hansson, L. 2 ABSTRACT The aim of the present work was to examine the existing algorithm for
More information3.8 HSP (High Solids Polyurethane)
Description is a single-stage topcoat designed for commercial and automotive refinishing. This product provides Superior UV durability as well as commercial grade chemical resistance. 3.8 HSP has excellent
More informationBarewood Octagon and Elongated Windows Installation Instructions
Step-by-step instructions to a beautiful window. Measuring and Installation of your new window from Century Specialty Windows couldn't be easier with our step-by-step instructions. Quality, function and
More informationContact person Date Reference Page Bengt-Åke Andersson 2013-11-27 3F020623A Rev1 1 (4) Wood Technology +46 10 516 54 34 bengt-ake.andersson@sp.
issued by an Accredited Testing Laboratory Contact person Bengt-Åke Andersson 2013-11-27 3F020623A Rev1 1 (4) Wood Technology +46 10 516 54 34 bengt-ake.andersson@sp.se 1002 ISO/IEC 17025 Nordic Comfort
More informationHIGHWAYS DEPARTMENT GUIDANCE NOTES ON ROAD SURFACE REQUIREMENTS FOR EXPRESSWAYS AND HIGH SPEED ROADS
HIGHWAYS DEPARTMENT GUIDANCE NOTES ON ROAD SURFACE REQUIREMENTS FOR EXPRESSWAYS AND HIGH SPEED ROADS Research & Development Division RD/GN/032 June 2007 1. Purpose ROAD SURFACE REQUIREMENTS FOR EXPRESSWAYS
More informationProperty Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1. 212 F (100 C) calculated VOC-US/Hong Kong. US EPA method 24 (tested)
Not approved 2063;2064 1,2 2063 ^(ValidationDate) 1 Product description This is a two component solvent free polyamine cured coating. It is a general purpose tank lining with good chemical resistance.
More informationApproved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 27 C calculated IED (2010/75/EU) (calculated)
Approved 402;2521 1 2521 zinc epoxy ^(ValidationDate). 1 Product description This is a two component polyamide cured zinc rich epoxy coating. It is a very high zinc dust containing product. It conforms
More informationGamma Sterilisation Validation according to ISO 11137 - Sterilising dose -
Synergy makes sence Gamma Sterilisation Validation according to ISO 11137 - Sterilising dose - MG-FSI72-105 Last revision: March 2011 5, Chemin du Catupolan - 69120 Vaulx en Velin - France - Tel. 33 (0)4
More informationSETSCO SERVICES PTE LTD TEST REPORT MICROSCOPIC ANALYSIS ON THE CONCRETE CORES FROM RETAINING WALL AT CHANGI AIRPORT TERMINAL 3 REVERTON ENGINEERING(S) PTE LTD 1. INTRODUCTION 2. MICROSCOPIC ANALYSIS 3.
More informationThe Prevention and Treatment of Mould Outbreaks in Collections
National Preservation Office The Prevention and Treatment of Mould Outbreaks in Collections NPO Preservation Guidance Preservation in Practice Series Author R.E. Child Head of Conservation National Museums
More informationFINAL FAILURE INVESTIGATION WESTCHESTER NORTH LAGOON BRIDGE. Anchorage, Alaska
FINAL FAILURE INVESTIGATION WESTCHESTER NORTH LAGOON BRIDGE Anchorage, Alaska August 2014 Prepared for: Municipality of Anchorage Project Management and Engineering P.O. Box 196650 Anchorage, Alaska 99519-6650
More informationHow to Build a Poker Table
How to Build a Poker Table www.pokertablematerials.com 10-Person Poker Table- 96 x 48 These are step by step instructions for building a poker table. The table will measure 48" x 96" and have a 4" wide
More informationCP CHEMICAL INDUSTRY PALLETS Edition: 6
April 00 CP CHEMICAL INDUSTRY PALLETS Edition: 6 Foreword The European chemical industry is using a large amount of wooden pallets for the distribution of goods. For environmental reasons there is a strong
More informationDecember 28, 2012 PARTIES INTERESTED IN PROPRIETARY WOOD PRESERVATIVE SYSTEMS COMMON REQUIREMENTS FOR TREATMENT PROCESS, TEST METHODS AND PERFORMANCE
December 28, 2012 TO: PARTIES INTERESTED IN PROPRIETARY WOOD PRESERVATIVE SYSTEMS COMMON REQUIREMENTS FOR TREATMENT PROCESS, TEST METHODS AND PERFORMANCE SUBJECT: Proposed Revisions to the Acceptance Criteria
More informationPressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
More informationFire Doors Explained. Presented by - Peter Barker
Fire Doors Explained Presented by - Peter Barker Objectives and Outline 1. The role of fire resisting doors 2. Proving the performance of fire resisting doors 3. Common problems and solutions The Role
More informationPERGOLAS AND CARPORTS
TECHNICAL DATA SHEET ISSUED BY TIMBER QUEENSLAND PERGOLAS AND CARPORTS RECOMMENDED PRACTICE // MARCH 2014 19 This data sheet contains Timber Queensland s recommendations for attached and detached timber
More informationPHOENIX 370-120 Product Data Sheet (Updated on 14-Jan-2012) www.phoenixasia.com.hk
DESCRIPTION A water borne thin film intumescent coating for the fire protection of structural steelwork. PRODUCT FEATURES AND RECOMMENDED USES Provides up to 120 minutes fire resistance to structural steelwork.
More informationINSTITUTE FOR TESTING AND CERTIFICATION, Inc. ITC Client s Guide. Provision of Gaming Machine Certification Services
INSTITUTE FOR TESTING AND CERTIFICATION, Inc. ITC Client s Guide Provision of Gaming Machine Certification Services Effective from: 01/05/2006 Prepared by: Michal Heš Date of publication: 1.5.2006 Place
More informationBETON. CONCRETE EFFECT IMITATION CONCRETE FOR A PURE AND MODERN EFFECT Application instructions primer - base - finish
BETON CONCRETE EFFECT IMITATION CONCRETE FOR A PURE AND MODERN EFFECT Application instructions primer - base - finish beton PRIMER The colour of the cachemire beton Primer is white, to get the best result
More informationTechnical Data SeaQueen
Technical Data SeaQueen Product description Antifouling SeaQueen is a tin free self-polishing antifouling based on a copolymer binder. IMO Anti-fouling System Convention compliant (AFS/CONF/26). Recommended
More informationIdentifying Patterns of Lumberyard Mold By: Patrick Moffett, REA, CHMM
By: Patrick Moffett, REA, CHMM Picture courtesy of Forintek. Canada s wood products research institute. Science behind identifying Sap Stain Fungi About Molds and Mold Growth Conditions Mold grows on organic
More informationBaumit Renders for Porotherm Masonry. Application Guidelines. n Light and easy application n Tried and tested
Renders for Porotherm Masonry Application Guidelines n Light and easy application n Tried and tested Porotherm is a Wienerberger Group brand Ideas with a future Renders for Porotherm Masonry International
More informationChrome Finishing For 3d Powder Prints
Chrome Finishing For 3d Powder Prints Powder Printing is definitely a very good technology for producing complex parts, but it can only generate the shape and that is not all about the appearance. Post
More informationE. INTERNAL PACKAGING
ANTI-CRRSIN MEASURES E. INTERNAL PACKAGING 1. ANTI-CRRSIN MEASURES During transport, handling and storage especially during overseas shipping more intensive stresses occur, which are often not sufficiently
More informationLaminar Flow Cabinets and Workstations
VERTICAL AND HORIZONTAL HEPA FILTERED SYSTEMS FOR PROCESS OR OPERATOR PROTECTION Laminar Flow Cabinets and Workstations For procedures requiring protection from particulate contamination and for aseptic
More informationNo. 64 November, 1992 Causes And Cures For Stains In Dried Lumber: Sticker Stain, Chemical Stain, Iron Stain and Blue Stain
No. 64 November, 1992 Causes And Cures For Stains In Dried Lumber: Sticker Stain, Chemical Stain, Iron Stain and Blue Stain One of the more common drying problems today is a dark area noted on dried, planed
More informationProfessional Thermohygrometer
User Manual Professional Thermohygrometer with NIST-Traceable Calibration Model 20250-21 THE STANDARD IN PRECISION MEASUREMENT Introduction The Digi-Sense Professional Thermohygrometer (Model 20250-21)
More informationCHAPTER 3.0 TIMBER PILE PROPERTIES
CHAPTER 3.0 TIMBER PILE PROPERTIES 3.1 INTRODUCTION The design of timber pile foundations requires a firm understanding of the mechanical properties of the timber pile. There are generally two species
More informationNATIONAL ASSESSMENT DIRECTIVE FOR THE PRODUCT CERTIFICATE FOR WOODEN SCAFFOLDING BOARDS
BRL 9923 dd. 2004-10-01 NATIONAL ASSESSMENT DIRECTIVE FOR THE KOMO PRODUCT CERTIFICATE FOR WOODEN SCAFFOLDING BOARDS Technical area E2 Accepted by the Committee of Experts of SKH dd. 15 th September 2004
More informationSEISMIC VELOCITY TRANSDUCER T1-40
SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute
More informationEVALUATION OF THE PERFORMANCE OF THE PROTECTIVE SURFACE COATINGS FOR CONCRETE
EVALUATION OF THE PERFORMANCE OF THE PROTECTIVE SFE COATINGS FOR CONCRETE Haimoon CHEONG * Hwangu YU *2 Taesong AHN *3 Byunghwan OH *4 ABSTRT: Chloride penetration into concrete is the main cause of the
More informationApproved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 30 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)
Approved 3140;3240;4320 1,2 3140 polyurethane ^(ValidationDate) 1 Product description This is a two component chemically curing aliphatic acrylic polyurethane coating. It has a glossy finish with very
More informationQuality Regulations for Profiles
Quality Regulations for Profiles September 2010 Quality Regulations for Profiles Page 2/42 Contents Preface... 4 1. Terms and Definitions... 5 1.1 Third parties... 5 1.2 Independent laboratories... 5 1.3
More informationApproved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 28 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)
Approved 735;739 1 735 phenolic/novolac epoxy ^(ValidationDate) 1 Product description This is a two component polyamine cured phenolic/novolac epoxy coating. It is a specially designed tank lining with
More informationProcess Control For Phosphate Coating A new military specification for phosphate coatings...
FOCUS: Pretreatment for Painting/Powder Coating Process Control For Phosphate Coating A new military specification for phosphate coatings... By JOSEPH T. MENKE Chemical Engineer U.S. Army Rock Island,
More informationOIL HEAT TREATMENT OF WOOD
OIL HEAT TREATMENT OF WOOD Sidorova, K. 1 ABSTRACT The investigation of thermal treatment of wood has led to the improvement of heat treatment with vegetable oils. The aim of this work has been to study
More informationProduct Guide. FrameGuard Total Wood
Product Guide FrameGuard Total Wood Protection from the Ground Up FrameGuard Total mold-resistant wood provides protection against mold, termites, and fungal decay in trusses, framing, OSB, SIPs, and other
More informationWeather Resistant Louvres
L---e Weather Resistant Louvres Type WSL Untreated aluminium Contents Application Realisation Safety instructions Contents Application Realisation Safety instructions Dimensions Sizes Installation Accessories
More informationBG Millag ApS Egegårdsvej 5 DK-5260 Odense S Tlf.: +45 88 61 26 00 info@millag.dk www.m
. BG Millag ApS Egegårdsvej 5 DK-5260 Odense S Tlf.: +45 88 61 26 00 info@millag.dk www.m ACCREDITED UNIT: DET NORSKE VERITAS, BUSINESS ASSURANCE, DANMARK A/S, TUBORG P ARKVEJ 8, 2., DK-2900, HELLERUP,
More informationRadiation Curable Components and Their use in Hard, Scratch Resistant Coating Applications
Radiation Curable Components and Their use in Hard, Scratch Resistant Coating Applications William Schaeffer Steven Tyson Indu Vappala Robert Kensicki Sartomer USA, LLC 502 Thomas Jones Way Exton, PA 19343
More informationTest Report: ICL/H11/979. BS 7837: 1996 Flammability performance for textiles used in the construction of marquees and similar textile structures.
Interscience Fire Laboratory Building 63 Haslar Marine Technology Park Haslar Road, Gosport Hampshire PO12 2AG United Kingdom Tel. : +44 (0) 20 8692 5050 Fax.: +44 (0) 20 8692 5155 Email: firetesting@intersciencecomms.co.uk
More informationBS 476: Part 7: 1997. Method For Classification Of The Surface Spread Of Flame Of Products. A Report To: Gurit (UK) Ltd. Document Reference: 312304
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS 476: Part 7: 1997 Method For Classification
More informationOngoing R&D projects in COST member countries
Ongoing R&D projects in COST member countries France Institute Acronym Research Groups Ecole Supérieure du Bois, Nantes École Nationale Supérieure des Technologies et Industries du Bois, Epinal Laboratoire
More informationResidential Decks. Planning and Development Services Department
Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: permitservices@opkansas.org Planning and Development Services Department Residential Decks
More informationFor the modifications listed below, the Qualification Approval tests in IEC 61215 and IEC 61646, shall be used as a guideline by the assessor:
Product or Process Modifications Requiring Limited CBTL Retesting to Maintain Certification This document sets forth a uniform approach to maintain the certification of products that have, or will, undergo
More informationThis document is a preview generated by EVS
EESTI STANDARD EVS-EN 927-6:2006 Paints and varnishes - Coating materials and coating systems for exterior wood - Part 6: Exposure of wood coatings to artificial weathering using fluorescent UV lamps and
More informationResisTech carpet maintenance treatment is designed to provide superior cleaning to significantly reduce carpet re-soiling.
ResisTech carpet maintenance treatment is designed to provide superior cleaning to significantly reduce carpet re-soiling. This keeps carpet looking cleaner longer, as part of your overall maintenance
More informationMold, Mildew, Fungi What s the Difference? Mold: The Good, the Bad and the Ugly
CEILING SYSTEMS Mold is receiving more attention within the construction industry than ever before. One reason is that it is becoming an increasingly visible subject in the media. Another is an increased
More informationStandard Operating Procedure
1.0 Purpose: 1.1 The characterisation of of main leukocyte subsets in peripheral blood cells from mice by flow cytometry. Reliable values of frequencies of leukocyte clusters are very much dependent on
More informationAkzoNobel in the detergents industry. Dishwashing
AkzoNobel in the detergents industry Dishwashing 2 3 For a sustainable future AkzoNobel in the detergents industry AkzoNobel is proud to be one of the world s leading industrial companies. In fact, we
More informationPackaging Validation according to ISO 11607
Synergy makes sence Packaging Validation according to ISO 11607 MG-FSI72-104 Last revision: March 2011 5, Chemin du Catupolan - 69120 Vaulx en Velin - France - Tel. 33 (0)4 72 81 22 62 - Fax : 33 (0)4
More informationClient ICS/Penetron International Ltd., 45 Research Way, Suite 203, East Setauket, NY 11733 Project Information of Client Subject Laboratory Testing of Penetron Waterproofing System Report No.: 95-387
More informationSolvent Cementing Instructions For Plastic Pipe & Fittings
Solvent Cementing Instructions For Plastic Pipe & Fittings Description Solvent cementing is the process of fusing plastic pipe and fittings by the use of an adhesive containing a suitable active solvent
More informationBio-materials for building envelope - expected performance, life cycle costing & controlled degradation. Anna Sandak PhD CNR-IVALSA
Bio-materials for building envelope - expected performance, life cycle costing & controlled degradation Anna Sandak PhD CNR-IVALSA Architect Michael Green of Vancouver says: The Earth grows our food.
More informationMethods of Verification of Cleaning in CSSD. Dr. Winfried Michels Mechelen Oct.2012
Methods of Verification of Cleaning in CSSD Dr. Winfried Michels Mechelen Oct.2012 Excerpts from ISO EN 15883-1 GTZ/PI/Dr. Michels 2 Before we consider which tracer to be monitored as a criterion for cleanliness
More informationITEM NO. DESCRIPTION BIDDER CODE NO. UNIT COST UNIT COST 1 GALLON 5 GALLON. 1 Oil Base Exterior House Paint Mobille Paint 5-18 $29.
BID ON: PAINT AND SUPPLIES BID NO: 13-22 OPENED: MARCH 1, 2013 @ 2:00 PM 1 Oil Base Exterior House Paint Mobille Paint 5-18 $29.00 XXX Acrylic Latex Exterior Gloss House Paint 2 Super White Sherwin Williams
More informationDetermination of N-cyclohexyl-diazeniumdioxide (HDO) containing compounds in treated wood using GC-MS
Application Note No. 051 Determination of N-cyclohexyl-diazeniumdioxide (HDO) containing compounds in treated wood using GC-MS by P Jüngel ¹), J Wittenzellner ²) and E Melcher ¹) ¹) Federal Research Centre
More informationThe Layman's Guide to ANSI, CEN, and ISO Bar Code Print Quality Documents
The Layman's Guide to ANSI, CEN, and ISO Bar Code Print Quality Documents AIM, Inc. 634 Alpha Drive Pittsburgh, PA 15238-2802 Phone: +1 412 963 8588 Fax: +1 412 963 8753 Web: www.aimglobal.org This Guideline
More informationSpillemyndigheden s Certification Programme Instructions on Penetration Testing
SCP.04.00.EN.1.0 Table of contents Table of contents... 2 1 Introduction... 3 1.1 Spillemyndigheden s certification programme... 3 1.2 Objectives of the... 3 1.3 Scope of this document... 4 1.4 Definitions...
More informationUniversity of Vermont
University of Vermont Department of Physical Plant Burlington, Vermont WATER INTRUSION GUIDELINES In accordance with: IIRC S500 IIRC S520 EPA Document 402-K-01-001 REVISED AND DISTRIBUTED BY: THE UNIVERSITY
More informationErrata NFPA 1. Fire Code. 2015 Edition
Errata NFPA 1 Fire Code 2015 Edition Reference: 2.2, Table 6.1.14.4.1(a) and (b), 13.3.1.6, 13.7.2.13.2.1, 14.11.3.3, 18.5.2, 18.5.3, 20.1.2, 20.1.5.12, 25.1.1, 25.3, 25.4, A.3.3.164.2, and A.13.3.2.9.1
More informationQuality Assurance (QA) & Quality Control (QC)
Quality Assurance (QA) & Quality Control (QC) In the laboratory Georges Ruta Water Quality Scientist City West Water 1 City West Water Water Supply & Sewerage Authority Melbourne Pop. >800,000 Area 580
More informationGuidance to Stock Assessment Workshop Working Groups (SAW WG) on Preparation/Format of SAW Reports for Peer Review
Guidance to Stock Assessment Workshop Working Groups (SAW WG) on Preparation/Format of SAW Reports for Peer Review J. Weinberg, SAW Chairman (last revised: 10/16/2014) Stock Assessment Terms of Reference
More informationHOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: 1-800-TEC-WOOD (832-9663)
HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: 1-800-TEC-WOOD (832-9663) Fire-Retardant-Treated Wood Framed Wall Assemblies GENERAL INFORMATION Fire-resistant construction
More informationRESIDENTIAL WOOD DECKS
RESIDENTIAL WOOD DECKS 1 A Building Permit is required for the construction of a wood deck where the deck is more than 600 mm above grade at any point. Definition: For the purposes of this pamphlet, a
More informationFire Retardant Cladding
An Introduction to Fire Retardant Cladding Page 1 First Consideration For any new timber cladding project you first of all need to assess whether fire retardant protection is required. The best way to
More informationDEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050
Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage
More informationMunchkin Heat Exchanger Maintenance
Munchkin Heat Exchanger Maintenance By: Mike Granahan *Refer to the appropriate boiler manual for your specific model number. Adjustment procedures will vary. Boiler shown below is an HTP Munchkin 80M
More informationOngoing R&D projects in COST member countries
Ongoing R&D projects in COST member countries Christian Brischke and Holger Militz University Hamburg, Center for Wood Science, Hamburg Georg August University Göttingen, Wood Biology & Wood Products,
More informationSterilization of narrow channels: how to ensure effectiveness in daily routine? Dr.ir. Josephus Paulus Clemens Maria Van Doornmalen Gomez Hoyos
April 2015 Sterilization of narrow channels: how to ensure effectiveness in daily routine? Dr.ir. Josephus Paulus Clemens Maria Van Doornmalen Gomez Hoyos 3M Deutschand GmbH, IPD, Decontamination University
More informationBUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE
BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE Toll Free Telephone Numbers Residential Services 800.454.3853 Commercial Services 800.653.5307 Utility Locating Company N.C. 800.632.4949 S.C. 888.721.7877
More informationTreating Treated Wood Decks. Terry L. Amburgey and Kevin W. Ragon
Treating Treated Wood Decks Terry L. Amburgey and Kevin W. Ragon Abstract The majority of the residential and non-residential decks in the US are fabricated using wood that has been pressure-treated with
More informationTechnical Data Sheet L1.05.03 Top coats. Mat Clear
Description Lesonal Mat clear provides a matt appearance over Lesonal Basecoat SB or may be intermixed with other suitable Lesonal clears to provide various gloss levels, for the protection and durability
More informationCERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
More informationEcophon Focus A. System range. Size, mm. XL 2000x600. XL 1800x600. XL 2400x600 T15 T24 Thickness (THK) Inst. Diagr. 1200x600 1200x1200 1600x600
Ecophon Focus A For applications where a robust suspended ceiling system is required. Ecophon Focus A has an exposed grid system. Each tile is easily demountable. The systems consist of Ecophon Focus A
More informationBRIDGE FIELD PAINTING, REPAINTING, 412 AND PAINT RESIDUE CONTAINMENT. A. Field Painting, Bridge Repainting and Residue Containment:
412.1 DESCRIPTION BRIDGE FIELD PAINTING, REPAINTING, 412 This specification contains the requirements for the removal, containment, and disposal of existing paint on steel surfaces, preparing the steel
More informationBXUV.D946 - Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263
BXUV.D946 Fire Resistance Ratings - ANSI/UL 263 Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements
More informationImage Lab Software How to Obtain Stain-Free Gel and Blot Images. Instructions
Image Lab Software How to Obtain Stain-Free Gel and Blot Images Instructions Table of Contents Obtaining Stain-Free Gel images...1 5 Obtaining Stain-Free Blot Images...6 9 If the Gel Doc XR+ or ChemiDoc
More informationPolyimide labels for Printed Circuit Boards
Polyimide labels for Printed Circuit Boards The right match for any PCB labelling application Labels on Printed Circuit Boards Matching product performance with application needs Printed Circuit Boards
More informationCutting force, Fc (N) ' 270. 100 110 120 130 Cutting speed (m/min)
159 Rake face Adhesion Rake face Nose wear Tool life = 50.2 min Nose wear Tool life = 30.9 min Figure 4.19 - Nose wear at the cutting edge of T4 coated carbide insert after machining Ti- 6Al-4V alloy with
More informationThe information provided below is intended for emergency recovery and response, not general treatment recommendations.
NATIONAL ARCHIVES AND RECORDS ADMINISTRATION PRESERVATION PROGRAMS The information provided below is intended for emergency recovery and response, not general treatment recommendations GENERAL INFORMATION
More informationSummit Racing Equipment s Paint and Auto Refinishing System was developed specifically for the home enthusiast and small shop owner wanting a
Summit Racing Equipment s Paint and Auto Refinishing System was developed specifically for the home enthusiast and small shop owner wanting a professional-looking paint job for hundreds of dollars less
More information