Technical Description

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Technical Description"

Transcription

1 abcxyz Contents 1. General Block Diagram First Steps Technical Data AS-Interface Pin Out Supply of Periphery Inputs Outputs Mechanical Data and Environmental Data Standards General The AS-Interface 2I/2O-PCBoard is a slave for the fieldbus system AS-Interface. It is designed to the specification V2.11 and may be configured in the extended address mode. The profile is S-B.A.*.E (2 outputs and 2 inputs). Up to two 2-wire or 3-wire binary sensors (proximity switches, light barriers,...) and two binary actuators (valves, signalling lamps, relais,...) may be connected to the module. The AS-Interface 2I/2O-PCBoard is intended for the use in terminal chambers of automation components (e.g. valve heads, drives, signal towers,...) in order to make them AS-Interface compatible. Optionally it is possible to reduce the output currents to 50%, 25% or 12,5% of the nominal value with an integrated pulse width modulation. Rev. 5, March 11, 2006 Page 1 of 6

2 AS-Interface PCBoard 2. Block Diagram Block diagram of the AS-Interface 2I/2O-PCBoard 3. First Steps At the time of shipping the AS-Interface 2I/2O-PCBoard has the address 0. In an AS- Interface network every slave must have an address in the range 1A to 31B. No address may occur more than once. Further it is not allowed to configure a standard slave and a slave with extended address mode with the same address (e.g. slave 17 and slave 17A or 17B) in the same network. Setting the address with the addressing tool Prior to installation of the slave in the network the address is set with the addressing tool which is connected to the ports ASi+ and ASi-. For further details please refer to the instructions of the addressing tool. Setting the address in the network Alternatively the AS-i 2I/2O-PCBoard may be connected to the AS-Interface network and the AS-Interface master can set the correct address (in projecting mode only). It has to be noted, however, that only one slave with address 0 may be connected to a network at any time. Page 2 of 6 Rev. 5, March 11, 2006

3 abcxyz Setting the parameters Optionally the AS-Interface parameters may be set. With the parameters the output currents may be individually reduced to 50%, 25%, 12,5% of the nominal value with an integrated pulse width modulation. This is a function of the AS-i master. 4. Technical Data 4.1 AS-Interface AS-Interface profile: S-B.A.*.E (Remote I/O) extended address mode: supported serial communication mode: --- reverse polarity protection: yes "Power" indication: --- "Fault" indication: --- AS-Interface voltage range: 26,5...31,6 V max. current consumption: 150 ma power on delay time: < 1 s AS-Interface specification: V2.11 AS-Interface IC A 2 SI-lite AS-Interface certificate: ZU The use of the data bits is shown in the table below: Input Data Image (IDI): Info (Interface 3) Bit 4 (DI3) Bit 3 (DI2) Bit 2 (DI1) Bit 1 (DI0) 0 Low (no current) Low (no current) High (current) High (current) Output Data Image (ODI): Info (Interface 3) Bit 4 (DO3) Bit 3 (DO2) Bit 2 (DO1) Bit 1 (DO0) Low (no current) Low (no current) High (current) High (current) If the parameter option is activated the AS-Interface parameters are used the following way: P2 P1 P0 =1 O1 / =0 O2 1 1 output continuous (Default) =1 O1 / =0 O2 0 1 output 50% (PWM frequency 125 Hz) =1 O1 / =0 O2 1 0 output 25% (PWM frequency 125 Hz) =1 O1 / =0 O2 0 0 output 12,5% (PWM frequency 125 Hz) Rev. 5, March 11, 2006 Page 3 of 6

4 4.2 Pin Out I+: sensor supply (24V DC) I-: 0V for sensor supply I3, I4: inputs (D2, D3) O1, O2: outputs (D0, D1) O-: 0V for outputs A+, A-: connection to the AS-Interface network The screw terminals are made for wires with cross sections in the range between 0,2 to 1,5mm Supply of Periphery supply power for sensors and actuators from AS-Interface network - nominal voltage: 24 V DC - voltage range (I+,I-) V DC (sum of all currents 100mA) short circuit protection: yes (current limit at 100mA) A short circuit or an overload of the supply will not be signalled to the master. Remark: The inputs I3 and I4, the supply I+, I-, O- and the outputs O1 and O2 shall not be connected to GND of the machine. 4.4 Inputs sensor supply: from AS-Interface (see 4.3) input circuit: positive switching voltage for High signal: 10 V input currents: - max. input current: < 18 ma Page 4 of 6 Rev. 5, March 11, 2006

5 abcxyz - High signal: 3 ma - Low signal: 1,5 ma input delay time: < 20µs status indication for inputs: --- input circuit: Remark: The inputs I3 and I4, the supply I+, I-, O- and the outputs O1 and O2 shall not be connected to GND of the machine. 4.5 Outputs actuator supply: from AS-Interface (see 4.3) output circuit: positive switching max. current: 100mA short circuit protection: yes overload protection: yes protection for inductive loads: utilisation category DC13 (IEC ) status indication for outputs: --- watchdog delay time: 40 ms output circuit: Remark: The inputs I3 and I4, the supply I+, I-, O- and the outputs O1 and O2 shall not be connected to GND of the machine. Rev. 5, March 11, 2006 Page 5 of 6

6 4.6 Mechanical Data and Environmental Data Attention: The module is exclusively intended for mounting in protected electrical environments (e.g. splitter boxes, terminal chambers,...). Warning: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. ambient temperature range: C protection rating: IP00 moisture: max. 95%, not condensing max. vibration level (temporarily): 1,5mm amplitude (10..55Hz) max. shock: 10g all dimensions in mm PB001/PB002: PB003/PB004: PB006: max. height: 15mm with terminal blocks (PB001/PB002) 11mm without terminal blocks (PB003/PB004) approx. 15mm potted version (PB006) diameter of mounting holes: 2mm / M3 5. Standards IEC :2000 This product is designed and manufactured for industrial applications and is not suitable for sale to the general public. Page 6 of 6 Rev. 5, March 11, 2006

Technichal Description

Technichal Description Technichal Description Content 1. General...1 2. Block Diagram...2 3. Use of the Z Plug...2 4. Technical Data...4 4.1 AS-Interface...4 4.2 M12 pin out...5 4.3 Undervoltage detection...5 4.4 Mechanical

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

Time relay module DC 24 110 V, programmable with positive action contacts

Time relay module DC 24 110 V, programmable with positive action contacts Subject to technical modification 815008.00 Identification Type ZR6-5008.00 Product version Datasheet version 00 Use/Application/Properties Description The programmable time relay consists of 1 relay with

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

Data Sheet SIMATIC S7-200 CPU 226 DC/DC/DC and CPU 226 AC/DC/Relay

Data Sheet SIMATIC S7-200 CPU 226 DC/DC/DC and CPU 226 AC/DC/Relay SIMATIC S7-200 and Table 1 Specifications for and Physical Size Dimensions (W x H x D) Weight Power loss (dissipation) CPU Features On-board digital inputs On-board digital outputs High speed counters

More information

Timing relay module DC 24 110 V, programmable

Timing relay module DC 24 110 V, programmable Subject to technical modification 815000.00 Identification Type ZR6-5000.00 Product version Datasheet version 00 Use/Area of application Description The programmable timing relay consists of 2 changeover

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves

More information

A.4 Specifications for the CPU 224

A.4 Specifications for the CPU 224 A.4 Specifications for the CPU 224 Specifications for and Physical Size Dimensions (W x H x D) Weight Power loss (dissipation) CPU Features On-Board digital inputs On-Board digital outputs High speed counters

More information

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

AS-i 3.0 PROFINET Gateways with integrated Safety Monitor

AS-i 3.0 PROFINET Gateways with integrated Safety Monitor AS-i 3.0 PROFINET Gateways with 2 / 1 Master, PROFINET Slave Up to 32 release circuits up to 6 safe output circuits on the Monitor safe relays or fast electronic (Figure similar) Safe AS-i outputs are

More information

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range) Description The sensors provide excellent results even with difficult-to-detect objects, e.g. small or thin parts, wires or bright metals. A variety of types cover a wide range of individual requirements

More information

Long-distance capacitive proximity sensor. Ordering Information EB-74. Sensors. Accessories (Order Separately) Mounting Brackets. Unshielded.

Long-distance capacitive proximity sensor. Ordering Information EB-74. Sensors. Accessories (Order Separately) Mounting Brackets. Unshielded. Long-distance capacitive proximity sensor Capacitive Proximity Sensor with Adjustable Sensitivity Detects both metallic and non-metallic objects (glass, lumber, water, oil, plastic, etc.) without direct

More information

E2K-C. Long-distance Capacitive Proximity Sensor. Ordering Information. Sensors. Accessories (Order Separately) Mounting Brackets.

E2K-C. Long-distance Capacitive Proximity Sensor. Ordering Information. Sensors. Accessories (Order Separately) Mounting Brackets. Long-distance Capacitive Proximity Sensor Capacitive Proximity Sensor with Adjustable Sensitivity Detects both metallic and non-metallic objects (glass, lumber, water, oil, plastic, etc.) without direct

More information

DMX2PWM 9 Channel Dimmer Setup Manual

DMX2PWM 9 Channel Dimmer Setup Manual DMX2PWM 9 Channel Dimmer Setup Manual www.ecue.de DMX2PWM 9ch Dimmer - Setup Manual e:cue control GmbH An OSRAM Company Rev. 1.3_01/2010 DMX2PWM 9ch Dimmer - Setup Manual Table of Contents 1. Device Overview....................................4

More information

Specifications for EM223 24 VDC 4 In/4 Out and EM223 24 VDC 4 In/4 Relay Out

Specifications for EM223 24 VDC 4 In/4 Out and EM223 24 VDC 4 In/4 Relay Out SIMATIC S7-200 EM223 Digital Combination Modules EM223 2 VDC In/ Out and EM223 2 VDC In/ Relay Out Table 1 Specifications for EM223 2 VDC In/ Out and EM223 2 VDC In/ Relay Out EM223 2VDC In/Out 6ES7 2231BF200XA0

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 1 semiconductor output Connection

More information

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053. PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection

More information

TWDLCDA40DRF compact PLC base Twido - 24 V DC supply - 24 I 24 V DC - 16 O

TWDLCDA40DRF compact PLC base Twido - 24 V DC supply - 24 I 24 V DC - 16 O Characteristics compact PLC base Twido - 24 V DC supply - 24 I 24 V DC - 16 O Main Range of product Product or component type Discrete I/O number 40 Discrete input number 24 Discrete input voltage Discrete

More information

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves

More information

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Diffuse reflection light scanner with background suppression. Dimensioned drawing FRK 93 Diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes 93_d1gb.fm Part No. 51 1169 1-3 V DC 15 75m m Scanner with foreground and background

More information

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided. Preliminary TECHNICAL DATASHEET #TDAX020700 HYDRAULIC VALVE CONTROLLER 24 I/O 5 Analog and 6 Digital Inputs 1 Temperature Sensor and 1 RPM Sensor Interface 2 PWM Inputs 6 Proportional and 4 ON/OFF Current

More information

ATV32HU75N4437 variable speed drive ATV32-7.5kW 400 V - 3P - Bluetooth built-in - w heat sink

ATV32HU75N4437 variable speed drive ATV32-7.5kW 400 V - 3P - Bluetooth built-in - w heat sink Characteristics variable speed drive ATV32-7.5kW 400 V - 3P - Bluetooth built-in - w heat sink Main Range of product Altivar 32 Product or component type Product destination Product specific application

More information

TXM1.8T. Triac module TX-I/O. Used for Thermic and motor-driven actuators (AC 24 V)

TXM1.8T. Triac module TX-I/O. Used for Thermic and motor-driven actuators (AC 24 V) s 8 179 8179p01 TX-I/O Triac module sed for Thermic and motor-driven actuators (AC 24 V) AC 24 V-controlled devices TXM1.8T 8 triac outputs (AC 24 V), configured individually for: Permanent contact Three-point

More information

VMU 100. Vibration Monitor VibroSmart FEATURES. Single-channel microprocessor-based monitor for mv/g accelerometer (constant current supply)

VMU 100. Vibration Monitor VibroSmart FEATURES. Single-channel microprocessor-based monitor for mv/g accelerometer (constant current supply) Vibration Monitor VibroSmart FEATURES Single-channel microprocessor-based monitor for mv/g accelerometer (constant current supply) Designed for reliable operation in severe industrial environments (IP

More information

ACS-30-EU-EMDR-10-MOD

ACS-30-EU-EMDR-10-MOD Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

DC 3-wire, NPN E2K-X8ME1 2M E2K-X8ME2 2M M18

DC 3-wire, NPN E2K-X8ME1 2M E2K-X8ME2 2M M18 Cylindrical Proximity Sensor EK- CSM_EK-_DS_E 1 General-purpose Threaded Capacitive Sensor Product lineup with M1, M1, and M models. Fixed sensing distance requires no sensitivity adjustment. Be sure to

More information

AS-i 3.0 Gateways, PROFIsafe via PROFINET or PROFIBUS

AS-i 3.0 Gateways, PROFIsafe via PROFINET or PROFIBUS AS-i 3.0 Gateways, 2 / 1 Master, PROFINET / PROFIBUS Slave AS-i Safety input slaves report via PROFIsafe AS-i Safety output slaves switch via PROFIsafe 1 Safety Monitor for 2 AS-i networks Operation using

More information

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS MSI-s/R, MSI-sx/Rx Configurable MSI provide important functions for the efficient flow of automated production processes Special features Combined guarding types by connecting up to 4 AOPDs Additional

More information

Type: EASY512 AC R Article No.: Ordering information Relay outputs Quantity 4 Power supply V DC 115/230 V AC. Description

Type: EASY512 AC R Article No.: Ordering information Relay outputs Quantity 4 Power supply V DC 115/230 V AC. Description Type: EASY512 AC R Article No.: 274103 Ordering information Relay outputs Quantity 4 Power supply V DC 115/230 V AC Description 8 digital inputs 4 relay outputs LCD display Operating buttons Screw terminals

More information

RM17UAS. Main. Product or component type. Product specific application. Relay monitored parameters

RM17UAS. Main. Product or component type. Product specific application. Relay monitored parameters Characteristics voltage control relay RM17-U - range 65..260 V AC Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main Range of

More information

DC 3-wire, NPN E2K-X8ME1 2M E2K-X8ME2 2M M18

DC 3-wire, NPN E2K-X8ME1 2M E2K-X8ME2 2M M18 Cylindrical Proximity Sensor EK- CSM_EK-_DS_E 1 General-purpose Threaded Capacitive Sensor Product lineup with M1, M1, and M models. Fixed sensing distance requires no sensitivity adjustment. Be sure to

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com This handbook has been designed as a guide to the installation and operation of King Pigeon Hi-Tech.Co.,Ltd DAM series. Statements

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor AS-i 3.0 Gateways AS-i 3.0 Gateways 2 / 1 AS-i Master, Slave 1 AS-i Safety Monitor for 2 s Operation using a single Monitor! Monitor processes safety slaves on two s Coupling between the two networks superfluous

More information

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111 , GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,

More information

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)

More information

Smart DeviceNet Remote I/O Terminals

Smart DeviceNet Remote I/O Terminals Smart DeviceNet Remote I/O Terminals ather and Use Information for Effective Preventive Maintenance et more useful data for preventive maintenance when you build cost-effective parallel information systems

More information

SA/S Switch Actuators

SA/S Switch Actuators ABB i-bus EIB / KNX SA/S Switch Actuators ABB STOTZ-KONTAKT GmbH - Folie 1 Range of Products SA/S x.x.x New development of a complete range of Switch Actuators (Binary outputs) Fulfils current demands

More information

UniPi technical documentation REV 1.1

UniPi technical documentation REV 1.1 technical documentation REV 1.1 Contents Overview... 2 Description... 3 GPIO port map... 4 Power Requirements... 5 Connecting Raspberry Pi to UniPi... 5 Building blocks... 5 Relays... 5 Digital Inputs...

More information

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output. Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

Speed monitor H. Safe monitoring of equipment and of safely reduced rotational speed (e.g. setup operation)

Speed monitor H. Safe monitoring of equipment and of safely reduced rotational speed (e.g. setup operation) Speed monitor 480 041 H. Safe monitoring of equipment and of safely reduced rotational speed (e.g. setup operation) + meets all applicable standards and guidelines + automatic, manual or monitored reset

More information

Medusa DMX Manual. 150mA (multiple channels) Servo Refresh rate Pulse range 90 range mode 1000μS to 2000μS 180 range mode 600μS to 2400μS

Medusa DMX Manual. 150mA (multiple channels) Servo Refresh rate Pulse range 90 range mode 1000μS to 2000μS 180 range mode 600μS to 2400μS Medusa DMX Manual The Medusa DMX is a 24-channel DMX controlled prop interface. It decodes DMX-512 data, and controls servos, LEDs, and switch outputs, allowing for remote animated control of props. To

More information

Electronic timer CT-TGD.12

Electronic timer CT-TGD.12 2CDC 251 098 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute

More information

Capacitive Proximity Sensors

Capacitive Proximity Sensors Capacitive Proximity Sensors Capacitive proximity sensors High level of temperature stability Enhanced sensing ranges for functional reserve High level of immunity against: - Electrostatic discharge, e.g.

More information

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850

More information

Model: DC-A2IO Advanced HVAC Controller

Model: DC-A2IO Advanced HVAC Controller Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

EE-SPW411. Through-beam Photomicrosensor with a sensing distance as long as 1 m. Long-distance Through-beam Photomicrosensor. Ordering Information

EE-SPW411. Through-beam Photomicrosensor with a sensing distance as long as 1 m. Long-distance Through-beam Photomicrosensor. Ordering Information Long-distance Through-beam Photomicrosensor /411 CSM 411_DS_E_6_1 Through-beam Photomicrosensor with a sensing distance as long as 1 m. Easy operation monitoring with bright light indicator. Wide operating

More information

Circuit diagram. Inteded use. Function

Circuit diagram. Inteded use. Function SNA 4043 K SNA 4063 K SNA 4044 K SNA 4064 K Basic unit for emergency stop and guard door applications Basic unit as per EN 62061 and EN ISO 13849-1 For safety category 4 and stop category 0 Single or twin

More information

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Combi switchbox with integrated 3/2 way pilot valve

Combi switchbox with integrated 3/2 way pilot valve H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled

More information

Universal Interface, 4-fold, FM US/U 4.1, GH Q631 0031 R0111

Universal Interface, 4-fold, FM US/U 4.1, GH Q631 0031 R0111 Universal Interface, -fold, FM, GH Q631 0031 R0111 SK 0060 B 98 The device has four channels which can be assigned parameters as inputs or outputs by selecting the application with the ETS2 program. Conventional

More information

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS) MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed

More information

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS 32F50(LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : OCT.

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS 32F50(LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : OCT. EXAMINED BY : FILE NO. CAS-10210 EMERGING DISPLAY ISSUE : OCT.23,2003 APPROVED BY : TECHNOLOGIES CORPORATION TOTAL PAGE : 10 VERSION : 2 CUSTOMER ACCEPTANCE SPECIFICATIONS MODEL NO. : 32F50(LED TYPES)

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

4.1-V-2 Item number... 3. 4.1-V-3 Installation... 4. 4.1-V-4 Set-up... 6. 4.1-V-5 Exchange... 7

4.1-V-2 Item number... 3. 4.1-V-3 Installation... 4. 4.1-V-4 Set-up... 6. 4.1-V-5 Exchange... 7 4.1-V Table of contents 4.1-V-1 Device data... 1 4.1-V-1.1 General information... 1 4.1-V-1.2 Device display... 2 4.1-V-1.3 Technical data... 2 4.1-V-1.4 Main and connection parameters... 3 4.1-V-2 Item

More information

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP EtherNet/IP, Modbus TCP, or PROFINET slave Integrated Ethernet switch Supports 10 Mbps/100 Mbps 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection 7/8" males, 5-pin, for power supply Separated power

More information

DC/DC Converter Model 1416

DC/DC Converter Model 1416 Power Conversion Model 1416 www.curtisinstruments.com Curtis Model 1416 is designed to be used on 24 and 6VDC battery-powered vehicles to provide reliable and regulated power to 24VDC accessories. Model

More information

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS MSI-m/R, MSI-mx/Rx Configurable MSI Safety Relay with function for efficient material flow in a packaging application Special features Sequential or Parallel with automatic mode detection MSI-mx for separate

More information

IMPORTANT. Always connect the battery first, in order to allow the Controller to recognize system voltage

IMPORTANT. Always connect the battery first, in order to allow the Controller to recognize system voltage Manual EN IMPORTANT Always connect the battery first, in order to allow the Controller to recognize system voltage Use a 12V (36 cells) solar array for a 12V system. Use a 24V (72 cells) solar array for

More information

Capacitive Proximity Sensor

Capacitive Proximity Sensor Capacitive Proximity Sensor X Threaded Cylindrical Capacitive Proximity Sensor Detects almost any kind of metallic and nonmetallic objects, including glass, lumber, water, oil, and plastic. Three choices

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

OPTOTRONIC OT 150/ /700 3DIMLT+ E Programmable 700mA Constant Current LED Power Supply with LEDset and 3DIM

OPTOTRONIC OT 150/ /700 3DIMLT+ E Programmable 700mA Constant Current LED Power Supply with LEDset and 3DIM Data Reference: For LED modules: 350 700 ma LED Nominal Voltage: 220 240 V AC Line Current, nominal: 720 ma @ 230V Mains Frequency: 50/60 Hz Output Current: 75 700 ma DC +/- 5% (350-700mA), see load diagram

More information

ENI 21, 22, 23 Optoelectric rotary speed sensors with pulse output

ENI 21, 22, 23 Optoelectric rotary speed sensors with pulse output Data Sheet 10/14-2.15-EN ENI 21, 22, 23 Optoelectric rotary speed sensors with pulse output Detection of rotational direction and rotational speed Signal height independent of rotary speed Logic signal

More information

Limit Switch Style Inductive Prox

Limit Switch Style Inductive Prox Limit Switch Style Inductive Prox Economical, Limit Switch Style Sensor with Plastic Body Low cost Wide operating voltages (10 to 0 VDC and 90 to 250 VAC) Directly switches AC loads up to 500 ma, DC loads

More information

Motor load monitoring relays

Motor load monitoring relays Motor load CM-E Range Motor load Motor load Fields of application The motor load monitor relay monitors the load states of single-phase and three-phase asynchronous motors. The evaluation of the phase

More information

AS-i 3.0 Gateways, PROFIsafe via PROFINET or PROFIBUS

AS-i 3.0 Gateways, PROFIsafe via PROFINET or PROFIBUS via PROFINET or AS-i 3.0 Gateways, via PROFINET or 2 / 1 Master, PROFINET / Slave AS-i Safety input slaves report via AS-i Safety output slaves switch via 1 Safety Monitor for 2 AS-i networks Operation

More information

E2K-L. Liquid Level Sensor. Applications. Ordering Information

E2K-L. Liquid Level Sensor. Applications. Ordering Information Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing

More information

PNOZsigma - Base units

PNOZsigma - Base units PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

Low Signal Relay. Ordering Information

Low Signal Relay. Ordering Information Low Signal Relay Compact size and low 5 mm (0.20 in) profile Low thermoelectromotive force Low magnetic interference enables highdensity mounting Utilizes OMRON s moving-loop design Bifurcated contacts

More information

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO New Product News G9EJ--E Compact Capable of Switching 4 V A DC loads Actualize a high capacity interruption through the function of extinction of magnetic arc by adopting high-efficiency magnetic circuit.

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.

More information

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series Programmable Terminal NPSeries Easy Setup with the Low-cost, Compact NP Series Simpler and More Versatile.OMRON s Compact NP Series Connect! Easier connection to OMRON PLCs and Temperature Controllers,

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

Monitor for Measurement of Speed and Detection of Direction Series D224.xxS2

Monitor for Measurement of Speed and Detection of Direction Series D224.xxS2 D Monitor for Measurement of Speed and Detection of Series D.xxS KEY FEATURES Speed and Monitor with sensor monitoring and self-test function Frequency range 0 Hz 00 khz Analog Output 0/ 0 ma Bright red

More information

E2K- 12 to 24 VDC (10 to 30 VDC) 100 to 220 VAC (90 to 250 VAC) Current consumption 15 ma 2.2 ma max. (Refer to Engineering Data.

E2K-  12 to 24 VDC (10 to 30 VDC) 100 to 220 VAC (90 to 250 VAC) Current consumption 15 ma 2.2 ma max. (Refer to Engineering Data. Capacitive Proximity Sensor X Threaded Cylindrical Capacitive Proximity Sensor Detects almost any kind of metallic and nonmetallic objects, including glass, lumber, water, oil, and plastic. Three choices

More information

Technical Information

Technical Information Reference: For use with LED light engines Geometry (l x w x h): Line voltage, nominal Perm. voltage fluctuations Line current, nominal Inrush current, typical Line frequency Protection Class Output operating

More information

R842 Electronic Relay For Electric Baseboards

R842 Electronic Relay For Electric Baseboards R84 Electronic Relay For Electric Baseboards Built-in transformer Universal replacement part Compatible with electronic T86 room sensor Description Viconics innovative R84 electronic relay has been designed

More information

TURCK Modular Industrial I/O PROFIBUS -DP Products

TURCK Modular Industrial I/O PROFIBUS -DP Products TURCK Modular Industrial I/O PROFIBUS -DP Products Piconet Gateways Rugged, Fully Potted Stations IP 67 Protection Small Footprint Automatic Baud Rate Sensing SDPL-0404D-0003 SDPL-0404D-0004 SDPL-0404D-1003

More information

SIMATIC. ET 200S distributed I/O IM151-1 COMPACT modules. Preface. What do COMPACT modules offer? Configuration options of the COMPACT modules

SIMATIC. ET 200S distributed I/O IM151-1 COMPACT modules. Preface. What do COMPACT modules offer? Configuration options of the COMPACT modules SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O Manual Preface What do COMPACT modules offer? 1 Configuration options of the COMPACT modules 2 IM151 COMPACT 32DI 24 VDC 3 (6ES7151-1CA00-1BL0)

More information

SYSTEM DESCRIPTION Termination Boards

SYSTEM DESCRIPTION Termination Boards PROCESS AUTOMATION SYSTEM DESCRIPTION Termination Boards Non-IS Termination Boards for Yokogawa CENTUM C3 and ProSafe RS ISO9001 With regard to the supply of products, the current issue of the following

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

Emergency lighting units EM converterled. EM converterled BASIC 50 V Emergency lighting LED Driver

Emergency lighting units EM converterled. EM converterled BASIC 50 V Emergency lighting LED Driver BASIC 50 V lighting Driver Product description lighting Driver for manual testing For modules with a forward voltage of 10 52 V SEV for output voltage < 60 V DC ow profile casing (21 x 30 mm cross-section)

More information

New XUY roller sensors

New XUY roller sensors Do you want to simplify the sensor integration in your conveyor systems? New XUY roller sensors for packet, boxes, letters on roller conveyors. Telemecanique Sensor s OsiSense TM XUY photoelectric sensors

More information

ABB Drives. User s Manual HTL Encoder Interface FEN-31

ABB Drives. User s Manual HTL Encoder Interface FEN-31 ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions

More information

Pressure Sensors. for neutral and slightly aggressive liquids and gases

Pressure Sensors. for neutral and slightly aggressive liquids and gases 1909P01 Pressure Sensors for neutral and slightly aggressive liquids and gases QBE2003-P QBE2103-P High-precision measuring Measuring range 0 to 60 bar relative Supply voltage AC 24 V / DC 12...33 V or

More information

RXL21.1 RXL22.1. Room controllers. Building Technologies Building Automation RXL

RXL21.1 RXL22.1. Room controllers. Building Technologies Building Automation RXL 3 877 3877P01 RXL Room controllers Communicating controllers for fan-coil applications FC-10, FC-11, FC12 RXL21.1 RXL22.1 The RXL21.1 and RXL22.1 room controllers are used for temperature control in individual

More information

Relay module, non overlapping contacts arrangement

Relay module, non overlapping contacts arrangement Subject to technical modification 716331 Identification Type RPE-6331 Part-No. 716331 Use/Area of application Description Relay module hermetically sealed with non overlapping contacts arrangement, according

More information

T3 Series. General Purpose IO for Integrators

T3 Series. General Purpose IO for Integrators General Purpose IO for Integrators -1- TABLE OF CONTENTS Table of Contents Technical Data 3 Standard Operation 4 Inputs 4 Outputs 4 Analog Output Calibration 4 Bandrate 4 Master Timer Clock Function for

More information