LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Size: px
Start display at page:

Download "LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0."

Transcription

1 LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mh O up to mh O Output signals -wire: ma -wire: ma / V others on request Special characteristics diameter 7 mm small thermal effect excellent accuracy excellent long term stability Optional versions IS-protection zone 0 SIL (Safety Integrity Level) cable protection via corrugated pipe different kinds of cables different kinds of seal materials The stainless steel probe LMP 07 is designed for continuous level measurement in water and clean or waste fluids. Basic element is a high quality stainless steel sensor with high requirements for exact measurement with excellent long term stability. Preferred areas of use are Water / filtrated sewage drinking water system ground water level measurement rain spillway basin pump and booster stations level measurement in container water treatment plants water recycling Fuel / Oil fuel storage tank farm

2 LMP 07 Technical Data Input pressure range Nominal pressure gauge [bar] Level [mh O] Overpressure [bar] Burst pressure > [bar] Output signal / Supply Standard -wire: ma / V S = 8... V DC Option Ex-protection -wire: ma / V S = V DC Options -wire -wire: ma / V S = V DC V / V S = V DC Performance Accuracy standard: nominal pressure < 0.4 bar: ± 0.5 % FSO nominal pressure 0.4 bar: ± 0.5 % FSO option : nominal pressure 0.4 bar: ± 0.5 % FSO option : for all nominal pressures: ± 0. % FSO Permissible load current -wire: R max = [(V S V S min) / 0.0 A] Ω current -wire: R max = 500 Ω voltage -wire: R min = 0 kω Influence effects supply: 0.05 % FSO / 0 V load: 0.05 % FSO / kω Long term stability ± 0. % FSO / year at reference conditions Response time -wire: < 0 msec; -wire: < msec accuracy according to IEC limit point adjustment (non-linearity, hysteresis, repeatability) Thermal effects (Offset and Span) Nominal pressure P N [bar] < 0.40 > 0.40 Tolerance band [% FSO] ± ± 0.75 in compensated range [ C] Permissible temperatures Permissible temperatures medium: C storage: C Electrical protection Short-circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 additional external overvoltage protection unit in terminal box KL or KL with atmospheric pressure reference available on request Electrical connection Cable with sheath material PVC (-5 70 C) grey PUR (-0 70 C) black FEP (-0 70 C) black cable with integrated air tube for atmospheric pressure reference Materials (media wetted) Housing Seals Diaphragm Protection cap stainless steel.4404 (6L) FKM others on request stainless steel.445 (6L) POM Explosion protection (only for ma / -wire) Approvals IBExU 0 ATEX 068 X / IECEx IBE.007X DX9-LMP 07 zone 0: II G Ex ia IIC T4 Ga zone 0: II D Ex ia IIIC T 85 C Da Safety technical maximum values U i = 8 V, I i = 9 ma, P i = 660 mw, C i 0 nf, L i 0 µh, the supply connections have an inner capacity of max. 7 nf to the housing Ambient temperature range in zone 0: C with p atm 0.8 bar up to. bar in zone or higher: C Connecting cables cable capacitance: signal line/shield also signal line/signal line: 60 pf/m (by factory) cable inductance: signal line/shield also signal line/signal line: µh/m Miscellaneous Option SIL 4 application according to IEC 6508 / IEC 65 Current consumption signal output current: max. 5 ma / signal output voltage: max. 7 ma Weight approx. 00 g (without cable) Ingress protection IP 68 CE-conformity EMC Directive: 004/08/EC ATEX Directive 94/4/EG 4 not in combination with the accuracy 0.%, only for 4...0mA / -wire pressure and level

3 LMP 07 Technical Data Wiring diagrams -wire-system (current) -wire-system (current / voltage) p supply + A p supply + VS VS supply I supply I / U signal + A / V Pin configuration Electrical connection cable colours (DIN 4700) Dimensions (in mm) Supply + Supply Signal + (only -wire) Shield wh (white) bn (brown) gn (green) ye/gn (yellow / green) standard option cable protection with corrugated pipe Total length of devices with accuracy 0. % FSO IEC increases by 5 mm!

4 LMP 07 Technical Accessories Data Mounting flange with cable gland Technical data Suitable for all probes Flange material stainless steel.4404 (6L) Material of cable gland standard: brass, nickel plated on request: stainless steel.405 (0); plastic Seal insert material: TPE (ingress protection IP 68) Hole pattern according to DIN 507 Version Size (in mm) Weight DN5 / PN40 D = 5, k = 85, b = 8, n = 4, d= 4.4 kg DN50 / PN40 D = 65, k = 5, b = 0, n = 4, d= 8. kg DN80 / PN6 D = 00, k = 60, b = 0, n = 8, d= kg Ordering type Ordering code DN5 / PN40 with cable gland brass, nickel plated ZMF540 DN50 / PN40 with cable gland brass, nickel plated DN80 / PN6 with cable gland brass, nickel plated Terminal clamp Technical data Suitable for all probes with cable mm Material standard: steel, zinc plated optionally: stainless steel.40 (04) Weight approx. 60 g Ordering type Terminal clamp, steel, zinc plated Terminal clamp, stainless steel.40 (04) Display program CIT 00 Process display with LED display CIT 50 Process display with LED display and contacts CIT 00 Process display with LED display, contacts and analogue output ZMF5040 ZMF806 CIT 50 Process display with LED display, bargraph, contacts and analogue output Ordering code Z0058 Z0057 CIT 400 Process display with LED display, contacts, analogue output and Ex-approval CIT 600 Multichannel process display with graphics-capable LC display CIT 650 Multichannel process display with graphics-capable LC display and datalogger CIT 700 Multichannel process display with graphics-capable TFT monitor, touchscreen and contacts PA 440 Field display with 4-digit LC display For further information please contact our sales department or visit our homepage: cable gland M6x.5 with seal insert (for cable mm) This data sheet contains product specification, properties are not guaranteed. Subject to change without notice. LMP07_E_006

5 Ordering code LMP 07 LMP Pressure in bar in mh O Input [mh O] [bar] Housing Stainless steel.4404 (6L) Diaphragm Stainless steel.445 (6L) Output 4 0 ma / -wire 0 0 ma / -wire 0 0 V / -wire Intrinsic safety 4 0 ma / -wire SIL 4 0 ma / -wire SIL with Intrinsic safety 4 0 ma / -wire E S ES Seals FKM Accuracy standard for P N 0.4 bar 0.5 % standard for P N < 0.4 bar 0.5 % 5 option for P N 0.4 bar 0.5 % option 0. % Electrical connection PVC-cable PUR-cable FEP-cable Cable length in m standard: m PVC 0 0 standard: 5 m PVC standard: 0 m PVC 0 0 standard: 5 m PVC 0 5 standard: 0 m PVC 0 0 special length PVC not in combination with SIL standard: m PUR 0 0 standard: 5 m PUR standard: 0 m PUR 0 0 standard: 5 m PUR 0 5 standard: 0 m PUR 0 0 special length PUR standard: 5 m FEP standard: 0 m FEP 0 0 special length FEP Special version standard cable protection with stainless steel corrugated pipe with pipe length in m cable with integrated air tube for atmospheric pressure reference Standard lengths / 5 / 0 / 5 / 0 m are available from stock, special lengths are manufactured order-related, price per meter (see above) This dokument contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals

More information

OPTIBAR P 2010 C Technical Datasheet

OPTIBAR P 2010 C Technical Datasheet OPTIBAR P 2010 C Technical Datasheet Hygienic pressure transmitter with flush welded diaphragm Wide variety thanks to modular design SIP/CIP compatible Hygienic process connections KROHNE CONTENTS OPTIBAR

More information

High-quality pressure transmitter for general industrial applications Model S-10

High-quality pressure transmitter for general industrial applications Model S-10 Electronic pressure measurement High-quality pressure transmitter for general industrial applications Model S-10 WIKA data sheet PE 81.01 for further approvals see page 4 Applications Machine building

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

Miniature pressure transmitter Model M-10, standard version Model M-11, version with flush diaphragm

Miniature pressure transmitter Model M-10, standard version Model M-11, version with flush diaphragm Electronic pressure measurement Miniature pressure transmitter Model M-10, standard version Model M-11, version with flush diaphragm WIKA data sheet PE 81.25 for further Approvals see page 3 MicroTronic

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female

More information

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm. Short-circuit protection

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm. Short-circuit protection 0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 2 mm Installation flush Output

More information

Pressure transmitter For refrigeration and air-conditioning applications Model AC-1, with ceramic measuring cell

Pressure transmitter For refrigeration and air-conditioning applications Model AC-1, with ceramic measuring cell Electronic pressure measurement Pressure transmitter For refrigeration and air-conditioning applications Model AC-1, with ceramic measuring cell WIKA data sheet PE 81.46 for further approvals see page

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding

More information

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61 Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:

More information

Magnetic field sensor magnet-inductive proximity sensor BIM-M12E-Y1X-H1141

Magnetic field sensor magnet-inductive proximity sensor BIM-M12E-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M12 x 1 Chrome-plated brass Rated operating distance 90 mm with DMR31-15-5 magnet DC 2-wire, nom.

More information

Features. Picture. Specifications

Features. Picture. Specifications Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Two wire system Piezoresistive measuring element Output signal 4-20 ma Conformity error ±0.5 % FS or Standard DIN measuring

More information

Supply unit for transmitters

Supply unit for transmitters JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

Magnetic field sensor magnet-inductive proximity sensor BIM-EG08-Y1X

Magnetic field sensor magnet-inductive proximity sensor BIM-EG08-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4301 Rated operating distance 78 mm with DMR31-15-5 magnet DC 2-wire, nom.

More information

Isolating power supplies and output isolators

Isolating power supplies and output isolators Isolating power supplies with HART Overview Analog input isolating power supply, function block diagram Analog input 0/4... 20 ma The isolating power supplies are used for the intrinsically safe operation

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications

More information

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6

More information

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element

More information

Float Switches with Permanent Magnet For Horizontal Installation Model HIF

Float Switches with Permanent Magnet For Horizontal Installation Model HIF Level Measurement Float Switches with Permanent Magnet For Horizontal Installation Model HIF WIKA Data Sheet LM 30.02 Applications Level measurement for almost all liquid media Pump/level control Chemical

More information

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor Special Features Wetted parts in stainless steel and PEEK Compact design Precise switching point with no requirement for calibration Process temperature 0... 5 C Measures media with DKvalues >.5 (DK =

More information

Pressure transmitter (2 wire) / switch for continuous or On/Off Control

Pressure transmitter (2 wire) / switch for continuous or On/Off Control transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Technical data machine connector M12 1, 4-pole according to IEC ; FIXCON-capable

Technical data machine connector M12 1, 4-pole according to IEC ; FIXCON-capable Data Sheet 902815 Page 1/7 JUMO Dtrans T100 Screw-in RTD temperature probe with/without transmitter for temperatures from -50 to +260 C EHEDG certification complies with ROHS for EU and China configuration

More information

Technical Data Sheet Positioner Type 824 TD_824. General data

Technical Data Sheet Positioner Type 824 TD_824. General data General data Mounting Enclosure material On linear actuators On quarter-turn actuators ARCA-integrated or acc. to IEC 534-6 (NAMUR) Range of stroke 10... 120 mm ARCA-integrated or acc. to VDI/VDE 3845

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building

More information

System 6000 Electropneumatic Converter for Direct Current Signals Type 6111 i/p Converter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6111 i/p Converter System 6000 Electropneumatic Converter for Direct Current Signals Type 6111 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush

More information

Level sensing pressure transmitter type 711

Level sensing pressure transmitter type 711 Level sensing pressure transmitter type 711 Pressure range 0... 0.1-16 bar The level sensing pressure transmitters of type 711 with a relative pressure measuring cell have an adjusted and amplified sensor

More information

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 17 mm Metal, GD-Zn Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8026 can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor output(s)

More information

LIPS M100 CYLINDER - LINEAR POSITION SENSOR

LIPS M100 CYLINDER - LINEAR POSITION SENSOR LIPS M100 CYLINDER - LINEAR POSITION SENSOR Intrinsically safe for Mining to: Non-contacting inductive technology to eliminate wear Travel set to customer s requirement High durability and reliability

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

Differential pressure sensors

Differential pressure sensors 1 923 1923P01 Differential pressure sensors for neutral or slightly aggressive gases and liquids QBE61.3-DP.. Operating voltage AC 24 V or DC 18...33 V Output signal DC 0...10 V Connecting male thread

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

Process Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

Process Automation. Sensors and Systems:  Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors Process Automation Process Automation Accurate Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors Flexible Sensors and Systems: www.fafnir.com Reliable TEMPERIX S TEMPERIX

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Mini pressure switch Stainless steel switch enclosure Model PXS

Mini pressure switch Stainless steel switch enclosure Model PXS Mechatronic pressure measurement Mini pressure switch Stainless steel switch enclosure Model PXS WIKA data sheet PV 34.36 Process Mini Series Applications Pressure monitoring and control of processes Safety-critical

More information

Conductive Level Switch FK 2 Technical Data:

Conductive Level Switch FK 2 Technical Data: Level switch for conductive liquids Optional electrode length adjustment Hygienic installation in accordance with EHEDG Wetted parts compatible with FDA requirements Potted electronic Not influenced by

More information

Humidity sensor. » eq DATASHEETS. use. type summery. Operating voltage AC 24 V/DC V Signal output DC 0...

Humidity sensor. » eq DATASHEETS. use. type summery. Operating voltage AC 24 V/DC V Signal output DC 0... Air Comfort Air treatment 9583 GB 2014.09.26 sensor for relative humidity and temperature STBZ-02» eq DATASHEETS Operating voltage AC 24 V/DC 13.5...35 V Signal output DC 0...10 V/4 20 ma for relative

More information

97100 NAMUR 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled flanged with NAMUR Interface, G 1/4, 1/4 NPT

97100 NAMUR 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled flanged with NAMUR Interface, G 1/4, 1/4 NPT 9700 NAMUR /, / & / way spool valves electromagnetic actuated, indirectly controlled flanged with NAMUR Interface, G /, / NPT For single and double operated actuators Crossover-free switching, switch-over

More information

Assembly. Front view. Switch S1. Power Rail

Assembly. Front view. Switch S1. Power Rail Temperature Repeater Features Assembly 1-channel isolated barrier V DC supply (Power Rail) Resistance and RTD input (Pt100, Pt500, Pt1000) Resistance output Accuracy 0.1 % Line fault detection (LFD) for

More information

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control

More information

SBM TECHNOLOGY PET Blow Valve Block

SBM TECHNOLOGY PET Blow Valve Block Advanced high pressure seal technology Robust, compact & lightweight design Proven & reliable technology Maintenance & service friendly High flow rate exhaust function Minimal dead space volume (< 35ml)

More information

Solenoid Valve Island Type 3965

Solenoid Valve Island Type 3965 Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and

More information

Flow switches Series AD/VH

Flow switches Series AD/VH Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,

More information

Linear encoders without bearings incremental System for linear motion feedback

Linear encoders without bearings incremental System for linear motion feedback Features Robust magnetic sensing method Output signals A 90 B with index signal Output circuits: HTL/push-pull and TTL/RS422 Resolution up to 5 µm (4-times evaluation) Non-contact, wear-free sensing system

More information

Dimensions. General specifications Switching element function Rated operating distance s n 1.5 mm

Dimensions. General specifications Switching element function Rated operating distance s n 1.5 mm Dimensions ø11 ø8 15 15,35 40 0102 Model Number ø10 Features With special adjustment Connection Technical Data N / N0 I 1/BN 2/BU L+ L- specifications Switching element function NAMUR NC Rated operating

More information

Programmable Temperature Transmitter Model : T700C

Programmable Temperature Transmitter Model : T700C f Programmable Temperature Transmitter Model : T700C Advantages Two wire 4~20mA Loop powered design Universal input signals RTD temperature sensor T/C elements Mv, V, ma DC signals Programmable function

More information

Air flow meter Model A2G-25

Air flow meter Model A2G-25 Electronic pressure measurement Air flow meter Model A2G-25 WIKA data sheet SP 69.04 Applications For measuring the air flows of radial ventilators For measuring air flows in ventilation pipes and ducts

More information

LTU 401. Technical Specification

LTU 401. Technical Specification LTU 401 Technical Specification Table of Contents Table of Contents LTU 401 Submersible Level Sensor... 2 Product... 2 Features... 2 Technical Features... 2 Approvals and Standards...2 Electrical specification...

More information

Ex Polyester Okta Box

Ex Polyester Okta Box - Glass fibre reinforced polyester enclosure system for applications in all Ex-areas - Empty enclosures for individual fittings and Ex e / Ex ia junction boxes - Enclosures with external fixing brackets

More information

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate 1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration

More information

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS Online data sheet PET-1CB010N10SVMC PET B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Pressure type Measuring range Ordering information Other models and

More information

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment

More information

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic

More information

Spring-diaphragm pressure gauges for differential pressure overload protected

Spring-diaphragm pressure gauges for differential pressure overload protected Spring-diaphragm pressure gauges for differential pressure overload protected 2 3 4 1 7 6 5 Function overview 1. Movement 2. Dial 3. Pointer 4. Transmission unit 5. Measuring spring 6. Diaphragm 7. Measuring

More information

SE 655(X) / SE 656(X) Toroidal Conductivity Sensors

SE 655(X) / SE 656(X) Toroidal Conductivity Sensors User Manual English SE 655(X) / SE 656(X) Toroidal Conductivity Sensors Latest Product Information: www.knick.de Description 3 The SE 655(X) and SE 656(X) toroidal conductivity sensors are particularly

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

Terminal Boxes Series 8146

Terminal Boxes Series 8146 Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm

More information

Operating Instructions for Pressure Sensors Heavy Duty Compact. Model: SEN-86../ SEN-87..

Operating Instructions for Pressure Sensors Heavy Duty Compact. Model: SEN-86../ SEN-87.. Operating Instructions for Pressure Sensors Heavy Duty Compact Model: SEN-86../ SEN-87.. 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating Principle...4

More information

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm Model Number Features Increased operating distance 8 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications

More information

Mobrey 9700 Transmitter

Mobrey 9700 Transmitter Product Data Sheet February 2015 IP0078, Rev DB Mobrey 9700 Transmitter Submersible Hydrostatic Level Transmitters Hydrostatic electronic level transmitters Factory sealed and tested for submersed duty

More information

Duct Humidity & Temperature Transmitter

Duct Humidity & Temperature Transmitter SDC-HT Duct Humidity & Transmitter Features Replaceable sensor element Humidity and temperature measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm 0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

ExCos-P Pressure sensor 20 Pa Pa

ExCos-P Pressure sensor 20 Pa Pa ExCos-P Pressure sensor 20 Pa... 7.500 Pa Electrical, explosion-proof pressure / differential pressure sensors 24 VAC/DC supply voltage, 0...10 V / (0) analogue output EC type-approved in acc. with ATEX

More information

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP) Features Variants options Glass fiber reinforced polyester (GRP) enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 16 enclosure size options Various terminal

More information

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau KA 180F/00/en/06.01 (a) 52010984 Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau Safety instructions The FTS 20 floating switch may only be used as a level limit switch

More information

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Control- and feedback head for integrated mounting on Robolux valves Type 2036 Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated

More information

CAPACITIVE LEVEL METERS CLM 36

CAPACITIVE LEVEL METERS CLM 36 CAPACITIVE LEVEL METERS CLM 36 For continuous level measurement of liquid and bulk-solid materials Direct mounting into containers, silos, vessels, basins, reservoirs, etc Easy and quick connecting by

More information

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461 D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex

More information

24011 series, 3/2 Direct solenoid actuated poppet valve

24011 series, 3/2 Direct solenoid actuated poppet valve 0 series, / > > Port size: / (ISO G or NPT), NAMUR Interface > > Main application: Single and double acting actuators > > TÜV-approval based on type examination DGRL 97//EC and IEC 68, multichannel up

More information

Temperature controller for rail mounting PID controller, dimensions 75 x 22.5 mm Model CS4R

Temperature controller for rail mounting PID controller, dimensions 75 x 22.5 mm Model CS4R Accessories Temperature controller for rail mounting PID controller, dimensions 75 x 22.5 mm Model CS4R WIKA data sheet AC 85.05 Applications Plant construction and industrial ovens Process engineering

More information

Pressure transducers. with flush connection. Pressure transducers. with SIL assessment. HydroFox for level measurement. Pressure transducers

Pressure transducers. with flush connection. Pressure transducers. with SIL assessment. HydroFox for level measurement. Pressure transducers with flush connection with SIL assessment HydroFox for level measurement OEM version Chapter Electronic pressure measuring instruments: pressure transducers, digital pressure gauges, pressure switches

More information

Humidity Sensor/Transmitter Assembly

Humidity Sensor/Transmitter Assembly Humidity Sensor/Transmitter Assembly Wall/Duct Space Outside Air (OSA) Overview Minco humidity and humidity/temperature transmitters are designed using an advanced microprocessor. Digital signal processing

More information

ATL Fuel Level Sender Probes

ATL Fuel Level Sender Probes T E C H N I C A L S P E C I F I C A T I O N The ATL EL-AD-151 (Resistance Output) and EL-AD-152 (Voltage Output) Fuel Level Senders are highly advanced sensors for continuously measuring the contents of

More information

Electronic Pressure Switch EDS 300

Electronic Pressure Switch EDS 300 Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5

More information

Compact pressure switch Flameproof enclosure Ex d Model PCA

Compact pressure switch Flameproof enclosure Ex d Model PCA Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring

More information

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow) Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow) Drawing 8c Drawing 9c U391_TA10C_DoP_e_150421 www.hoentzsch.com 1 of 5 Measured

More information

Pressure Sensors. for neutral and slightly aggressive liquids and gases

Pressure Sensors. for neutral and slightly aggressive liquids and gases 1909P01 Pressure Sensors for neutral and slightly aggressive liquids and gases QBE2003-P QBE2103-P High-precision measuring Measuring range 0 to 60 bar relative Supply voltage AC 24 V / DC 12...33 V or

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

Technical data sheet TDS0070

Technical data sheet TDS0070 Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

QFM21... Duct sensors. Symaro. for relative humidity and temperature

QFM21... Duct sensors. Symaro. for relative humidity and temperature 1 864 1864P01 Symaro Duct sensors for relative humidity and temperature QFM21... Operating voltage AC 24 V / DC 13.5...35 V Signal output DC 0...10 V / 4 20 ma for relative humidity Signal output DC 0...10

More information

Precision digital pressure gauge Model CPG1500

Precision digital pressure gauge Model CPG1500 Calibration technology Precision digital pressure gauge Model CPG1500 WIKA data sheet CT 10.51 for further approvals see page 4 Applications Oil and gas industry Maintenance and service facilities Calibration

More information

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

UNIK 5600/5700 Marine Certified Pressure Sensing Platform GE Measurement & Control UNIK 5600/5700 Marine Certified Pressure Sensing Platform The new UNIK 5600/5700 carries marine certification for most zones on-board ship, as well as Intrinsically Safe certifications.

More information

SINEAX VK 616 Programmable Temperature Transmitter for RTD and TC inputs

SINEAX VK 616 Programmable Temperature Transmitter for RTD and TC inputs SINEAX VK 66 for installation in the terminal head of a temperature sensor DIN 79, Shape B 00 II () G Application SINEAX VK 66 is a two-wire head-mounted transmitter. It is designed for measuring temperature

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics 3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,

More information

Data Sheet PS1B Pressure Switch

Data Sheet PS1B Pressure Switch Data Sheet PS1B Pressure Switch Main Features Pressure Ranges 0 to 6 up to 0 to 600 bar (gage) Electrical Connection G 1/4 A DIN 3852-E or -A Pressure Connection Output Signal M12-4 Pin 4-20 ma, Programmable

More information

Inductive linear position sensor LI500P0-Q25LM0-LIU5X3-H1151

Inductive linear position sensor LI500P0-Q25LM0-LIU5X3-H1151 Rectangular, aluminium / plastic Versatile mounting possibilities LED indicates measuring range Immune to electromagnetic interference Extremely short blind zones Resolution, 12-bit 4-wire, 15 30 VDC Analog

More information

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands: Oil & Gas / Heavy Industry EX-Proof Stainless Steel Shaft Encoder - Ø 68 mm Shaft - Ø 10 mm to Ø 5/8 inch Resolution up to 10,000 ppr IP 66 (IP 67 option) ATEX certified EX-Proof IECEx certified EX-Proof

More information

18 mm Diameter DC 4 Wire

18 mm Diameter DC 4 Wire 18 mm Diameter DC 4 Wire Capacitive Short circuit & reverse polarity protection Improved EMC and ESD Shielding Protection degree IP65 NPN, NO+NC S5000 S5022 S5010 S5032 PNP, NO+NC S5001 S5023 S5011 S5033

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment

More information

Flowmeter for Gases and Installation in Existing Pipes

Flowmeter for Gases and Installation in Existing Pipes Flowmeter for Gases and Installation in Existing Pipes Type can be combined with... Depth scale for accurate installation Usable in pipes from 1/2 " up to 12" (DN300) Easy installation under pressure Analogue

More information