Energy efficiency of Russian and. Norwegian residential buildings Comparative study. Statsministerbesøk ved Høgskolen i Narvik 23.
|
|
- Miles Lindsey
- 7 years ago
- Views:
Transcription
1 Energy efficiency of Russian and Statsministerbesøk ved Høgskolen i Narvik 23. august Norwegian residential buildings Comparative study Researcher Olga Zakharova Sustainable Buildings for the High North Department of Building and Energy Narvik University College, Norway
2 Agenda In parts of northern Norway and Russia Building inventory. Energy consumption. Technical requirements for the buildings energy performance criteria.
3 The most common building type Norway Detached house Russia Apartment block
4 Building inventory Norway Russia Area per capita 53.4 m 2 Norway total 25.9 m 2 Arkhangelsk region 24.5 m 2 Murmansk region
5 Energy consumption in Norway Composition of energy consumption in households
6 Energy consumption in Russia Energy use accounts for a large percentage of the Russian economy. District heating takes about 71 percent of the entire Russian energy supply.
7 Comparison of energy consumption Norway Russia Average energy consumption in residential buildings kwh/m kwh/m 2 year only for heating
8 Legislation in Norway Main normative documents of existing legislation: Technical regulations: TEK10 - Regulation on technical requirements for buildings construction. - Requirements. Calculation standard: NS3031 «Calculation of energy performance of buildings». - calculation method description (monthly, simplified dynamic or dynamic). - standardized input data for some characteristics (climate, internal load, etc).
9 Legislation in Russia The Federal Law 261 On energy saving. Thermal protection of buildings. Heating, ventilation and air conditioning.
10 Norwegian Requirements, TEK10 1. Energy measures A set of energy characteristics must be fulfilled. 2. Energy budgets / limit Total net energy demand shall not exceed the budgets. 3. Minimum requirements Requirements that must be fulfilled either 1. or 2. is used to fulfil the regulation. 4. Energy supply requirements Limitations regarding direct electric heating and fossil fuels.
11 Requirements in Norway Energy measures Outer wall Roof U-value, [W/m 2 K] Floor to ground and unheated spaces Windows and doors included frame Air tightness, air change per hour at 50 Pa pressure difference (dwellings) 1.5 (other)
12 Requirements in Norway Minimum requirements Outer wall Roof U-value, [W/m 2 K] Floor to ground and unheated spaces Windows and doors included frame Air tightness, air change per hour at 50 Pa pressure difference
13 Requirements in Russia Energy measures Building category Residential building Degree days, o C days 6000 Outer wall Roof U-value, [W/m 2o C] Floor to ground and unheated spaces Window and door included frame
14 Comparison of requirements Energy measures U-value, [W/m 2 K] Country Norway Energy measures Outer wall Roof Floor to ground and unheated spaces Windows and doors included frame Minimum Russia Energy measures
15 Requirements Energy budgets / limit Norway building category. heated available area (only for small house). Russia building category. number of floors. heated available area (only for small house).
16 Comparison of requirements Energy budgets / limit Building category Apartment building Number of floors Heated available area, m 2 Overall energy limitation Norway 115 kwh/m 2 heated available area per year Russia W/(m 3 o C) Russia W/(m 3 o C) Small house Norway /m 2 heated available area kwh/m 2 per year Russia W/(m 3 o C)
17 Comparison of energy classification/ label Norway Russia All new buildings and buildings which will be sold or rented All Mandatory Classes Scale Municipal buildings for new and existing buildings separately Based on EU s directive A B C D E F G now A++ A+ A B+ B C+ C C- D E in development A B C D E F G Absolute Value Relative
18 Comparison of energy classification/ label Apartment building 9 floors flat 75 m 2 For Russia baseline is in development Country Energy supplied per m 2 heated available area A B C D E F G Norway (75m2) Russia (9 floors) > F kwh/m > F kwh/m 2 year
19 Summary Residences. Used area per capita. Energy supply: 78% Electricity in Norway. 71% District heating in Russia. Energy consumption. Calculations methods/parameters/units of measurement.
20 Suggested future work Common technical requirements for buildings construction in northern Russia and Norway. Based on EU s directive. Common calculations methods/parameters/units of measurement. Research of energy consumption for industrial buildings. Energy consumption per person. Indoor environment. Management, operation and maintenance of buildings. Market analysis.
21 Statsministerbesøk ved Høgskolen i Narvik 23. august Thank you for your attention!
Towards low energy buildings the development of building regulations in Norway. Clara Good, Norut Narvik Oulu, 27 May 2011
Towards low energy buildings the development of building regulations in Norway Clara Good, Norut Narvik Oulu, 27 May 2011 Presentation layout Norut Narvik Research Institute Background: buildings and energy
More informationTwinning «Improvement of the Energy Efficiency in Turkey»
Twinning «Improvement of the Energy Efficiency in Turkey» SECTOR BUILDING WORKSHOP Thermal Rehabilitation of Existing Buildings and Energy Building Code Residential energy efficiency overview in Ankara:
More informationEnergy audit in Finland
Energy audit in Finland NorTech Oulu Lauri Mikkonen Energy Audit in Finland An energy audit tells about the energy efficiency and total energy consumption in a building, including all consumed heating,
More informationNorwegian Tax Authority - Oslo Norway
1. INTRODUCTION Norwegian Tax Authority - Oslo Norway PROJECT SUMMARY Year of construction - 1980 No previous energy renovations SPECIAL FEATURES Main topics in the renovation are: High insulated pre fabricated
More informationNorwegian Tax Authority - Oslo Norway. Arne Førland-Larsen
Norwegian Tax Authority - Oslo Norway Arne Førland-Larsen Vienna 5 th of September 2012 Magma Center Tenerife foto Torben Eskerod 2 Fredrik Selmers vei 4 sett fra Strømsveien 3 Environmental goals Initially
More informationBuilding Standards Conservatory Roofs Meeting 28 Nov 2012
Conservatory Roofs Meeting 28 Nov 2012 Reason for hosting this meeting Availability of new roofing systems Increasing popularity in changing from transparent to opaque roof finishes Lack of clarity and
More informationGreen Affordable Housing Development Case Eco-Viikki, Finland
Green Affordable Housing Development Case Eco-Viikki, Finland Heikki Rinne Project Manager June 25, 2009, Washington D.C. 7.10.2008 Taske /KM/MHL Information on Helsinki Population Total 576,600 Men 47
More informationCase study on residential building renovation and its impact on the energy use and thermal comfort
Case study on residential building renovation and its impact on the energy use and thermal comfort Hanne Kauko, Maria Justo Alonso, Ole Stavset and Ingrid Camilla Claussen SINTEF Energy Research Motivation
More informationThe first apartment house renovation with Passive House components in Norway
14th International Passive House Conference Dresden, May 28, 2010 Michael Klinski Tor Helge Dokka The first apartment house renovation with Passive House components in Norway 168 flats, onebedrooms (55
More informationA Classification of Passive House for Swedish Conditions
A Classification of Passive House for Swedish Conditions Åsa Wahlström and Svein Ruud, SP Technical Research Institute of Sweden Martin Erlandsson and Jonas Norrman, IVL Swedish Environmental Research
More informationFABRIC ENERGY EFFICIENCY FOR PART L 2013
Informing the Part L 2013 consultation FABRIC ENERGY EFFICIENCY FOR PART L 2013 WORKED EXAMPLES AND FABRIC SPECIFICATIONS February 2012 Introduction This report has been produced by the Zero Carbon Hub
More informationA guide to energy performance certificates for the Construction, sale and let of non-dwellings
A guide to energy performance certificates for the Construction, sale and let of non-dwellings Preface This document is intended to give a simplified overview of Commercial Property Energy Certification.
More informationDienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses
Passiv Haus Institut Passivhaus Dienstleistung GmbH Dr. Wolfgang Feist Rheinstr. 44/46 Rheinstr. 44/46 D-64283 Darmstadt D-64283 Darmstadt www.passiv.de www.passivhaus-info.de Certification as "Quality
More informationZERO CARBON HOMES AND NEARLY ZERO ENERGY BUILDINGS. UK Building Regulations and EU Directives
ZERO CARBON HOMES AND NEARLY ZERO ENERGY BUILDINGS UK Building Regulations and EU Directives This leaflet summarises the UK s proposed Zero Carbon Standard for Homes, and the EU s new Nearly Zero- Buildings
More informationInnovative solution for heat recovery of ventilation air in older apartment buildings - with low intervention affecting the residents
Innovative solution for heat recovery of ventilation air in older apartment buildings - with low intervention affecting the residents Innovative solution for heat recovery of ventilation air in older apartment
More informationPROMOTION OF ENERGY EFFICIENCY THROUGH THE HOUSING MODERNISATION IN LITHUANIA
PROMOTION OF ENERGY EFFICIENCY THROUGH THE HOUSING MODERNISATION IN LITHUANIA Daiva Matonienė Vice-Minister Ministry of Environment Vilnius, Lithuania September,2013 RESIDENTIAL ENERGY EFFICIENCY 2 Lithuania
More informationCity of Cincinnati Pamphlet Residential Lease Option Contract
City of Cincinnati Pamphlet Residential Lease Option Contract PLEASE READ THIS BROCHURE CAREFULLY! YOU SHOULD READ THIS BROCHURE BEFORE YOU SIGN A LEASE WITH OPTION TO BUY AGREEMENT! This Pamphlet explains
More informationA comparative study of energy certification systems for buildings
A comparative study of energy certification systems for buildings Jelena Milicevic Master's Thesis Submission date: April 2014 Supervisor: Vojislav Novakovic, EPT Norwegian University of Science and Technology
More information1..GENERAL DATA 2. CLIMATIC DATA. Location
1..GENERAL DATA Location Szentendre, Downtown, Hungary Property Community centre of Szentendre, Public, Municipality of Szentendre Year of Building: End of 19th Century Present use (1) Community centre
More informationTHE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT.
THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT. A Diagrammatic representation of the relationship between the
More informationEcofys VII U-Values for Better Energy Performance of Buildings
Ecofys VII U-Values for Better Energy Performance of Buildings Quantifying the potential I II III IV & V VI Climate Protection Regulation Cost Effectiveness Enlarged EU Price Scenario Key figures from
More informationGUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.
GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS. This leaflet provides guidance on how to attain compliance with The Building (Amendment) Regulations (Northern Ireland) 2006, Part
More informationThe climatic challenge of designing a prefabricated catalogue house meeting the criteria of the Norwegian passive house standard
Passivhus Norden 2013 The climatic challenge of designing a prefabricated catalogue house meeting the criteria of the Norwegian passive house standard Silje Korsnes, SINTEF Building and Infrastructure,
More informationIEA SHC Task 47 Renovation of Non-Residential Buildings towards Sustainable Standards
Date of revision: 15.6.2012 Osram Culture Centre Copenhagen, Denmark Valhalsgade 4, 2200 Copenhagen N 1. INTRODUCTION PROJECT SUMMARY Construction year: 1953 Energy renovation: 2009 No past energy renovations
More informationFACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS
FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS 1 Ralf Lindberg, Professor Minna Korpi, M.Sc. Juha Vinha, Dr.Tech. June 11, 2008 Department of Civil Engineering, Tampere University of Technology 2 BACKGROUND
More informationBuilding Energy Labels: The Swiss MINERGIE Label
Building Energy Labels: The Swiss MINERGIE Label Chennai, October 8 th, 2010 Heinrich Gugerli, Head Sustainable Building Group heinrich.gugerli@zuerich.ch www.stadt-zuerich.ch/nachhaltiges-bauen Energy
More informationImplementation of the EPBD in Cyprus. Status in November 2010. 1 > Introduction. 2 > Certification. Cyprus
Implementation of the EPBD in Cyprus Status in November 2010 Constantinos Xichilos Energy Service Ministry of Commerce, Industry and Tourism Nicos Hadjinicolaou Energy Service Ministry of Commerce, Industry
More informationAssessment Methods. 15 th November 2010 Huw Jenkins Simon Lannon
Assessment Methods 15 th November 2010 Huw Jenkins Simon Lannon Assessment Methods Program Country Year Program Country Year 1 R-2000 Canada 1982 12 LEED US 2000 2 P-mark Sweden 1989 13 ECO-Quantum Netherlands
More information3.14 <NL> The Netherlands
The Netherlands 213 3.14 The Netherlands (by EPISCOPE partner DUT) 3.14.1 Current Legal s and Status of National NZEB Definition for Residential Buildings in the Netherlands In October 2012,
More informationPortuguese Certification System for Energy an Indoor Air Quality Statistical Information about the Portuguese Certification System
Portuguese Certification System for Energy an Indoor Air Quality Statistical Information about the Portuguese Certification System Manuel Casquiço/ ADENE Tabula Expert Workshop - Energy Assessment of National
More informationEnergy Efficient HVAC-system and Building Design
Energy Efficient HVAC-system and Building Design Maija Virta 1, Harri Itkonen 1, Panu Mustakallio 1, Risto Kosonen 1 1 Halton Oy, Finland Corresponding email: maija.virta@halton.com SUMMARY This paper
More informationSistema de Etiquetagem Energética de Produtos (SEEP) Energy Labeling System for Products
Sistema de Etiquetagem Energética de Produtos (SEEP) Energy Labeling System for Products 10 reasons for an energy labeling system (1/2) The buildings sector is responsible for a considerable share of final
More informationMinergie and Minergie-P, the Swiss Energy Labels Armin Binz, Institute of Energy in Building
Minergie and MinergieP, the Swiss Energy Labels Armin Binz, Institute of Energy in Building Energy and Sustainability from Concepts to Labels Concepts Methods and Instruments Standards and Labels SIA 8/,
More informationDelivering on innovation and market uptake. Best-in-cases of nzeb. Ramon Pascual Bucharest May 8th, 2015
www.zebra2020.eu Delivering on innovation and market uptake. Best-in-cases of nzeb Ramon Pascual Bucharest May 8th, 2015 Outline nzeb Database Best in cases of nzeb Climates in Europe Preliminary results
More informationENERGY STATEMENT for a proposed new residential care home at Great North Road, Doncaster, South Yorkshire, DN6 7EJ
ENERGY STATEMENT for a proposed new residential care home at Great North Road, Doncaster, South Yorkshire, DN6 7EJ Ref. No: 12/02870/FULM Contents 1. General... 2 2. Planning Condition... 2 3. Development...
More informationBYG DTU. Thermal properties of window frame Type 1 Sheet: 1. Type: Side, top and bottom profile. Source file: Format: dwg/dxf bmp
Thermal properties of window frame Type 1 Sheet: 1 Type: Side, top and bottom profile Profile: Frame profile made of wood and a GRP profile mounted with a sealed triple glazing unit. Materials: Wood GRP
More informationCAN DEMAND CONTROLLED VENTILATION REPLACE SPACE HEATING IN OFFICE BUILDINGS WITH LOW HEATING DEMAND?
Topic B3: Control of indoor environment CAN DEMAND CONTROLLED VENTILATION REPLACE SPACE HEATING IN OFFICE BUILDINGS WITH LOW HEATING DEMAND? Axel CABLE 1,*, Mads MYSEN 1,2, Kari THUNSHELLE 1 1 SINTEF,
More informationA global list. The Fortification Depot A CO 2 -reduction project
The Fortification Depot A CO 2 -reduction project A global list Passive measures: Windows, glazing, solar shading Insulation of walls, roofs, floors Improving air tightness 1 A global list Technical measures:
More informationSELECTIVE GLAZING FOR SUN CONTROL
SUN CONTROL GLAZING SELECTIVE GLAZING FOR SUN CONTROL Sun Factor 1st level performance for direct solar energy Solar energy control Solar control coating Only if the glass is exposed to sun rays! 2nd level
More informationImplementation of the EPBD in Sweden. Status in November 2010. Sweden. Introduction. Hans-OK Hjorth Boverket
Implementation of the EPBD in Sweden Status in November 010 Hans-OK Hjorth Boverket Thomas Johansson Boverket Ola Svensson Boverket Sweden National websites and other social media: www.boverket.se www.energimyndighete
More informationCO2 Emissions. Indirect CO 2. Emissions Electricity and Heat Production 25 % Direct Emissions AFOLU 24 % Energy 1,4% Buildings 6,4 % Industry 11 %
CO2 Emissions Direct Emissions AFOLU 24 % Buildings 6,4 % Transport 14 % 49 Gt CO2 eq (2010) Indirect CO 2 Emissions Electricity and Heat Production 25 % Energy 1,4% Industry 11 % Transport 0,3 % Industry
More informationD5.1 National reports on energy certification of buildings PORTUGAL
- Energy Certification, Information And Communication Technologies For User Satisfaction D5.1 National reports on energy certification of buildings PORTUGAL 1 2 Statement of originality This deliverable
More informationPassiv Haus Institut. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses
Passiv Haus Institut Dr. Wolfgang Feist Rheinstr. 44/46 D-64283 Darmstadt www.passiv.de Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses Passive Houses are
More informationLow energy class 1 typehouses according to the Danish building regulations
Low energy class 1 typehouses according to the Danish building regulations Jørgen Rose, Senior Researcher, Department of Energy and Environment, Danish Building Research Institute, Aalborg University;
More informationENERGY AUDITS IN DWELLING BUILDINGS IN LATVIA. DATA ANALYSIS
ENERGY AUDITS IN DWELLING BUILDINGS IN LATVIA. DATA ANALYSIS SUMMARY D. BLUMBERGA*, A. BLUMBERGA, V. VITOLINS Riga Technical University Kronvalda bulvaris 1, LV1010, Riga, Latvia dagnija@btv.lv Tel.: +
More information2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012
2012 Ontario Building Code Requirements for New Construction Bradford West Gwillimbury Building Division March 5, 2012 1 Ontario Building Code changes Applicable to permits applied for after December 31,
More informationModule 3.7. Thermal bridging
Module 3.7 Thermal bridging Learning Outcomes On successful completion of this module learners will be able to - Describe construction details which influence thermal bridging. 2 Introduction to thermal
More informationRULING OF THE MINISTER OF MUNICIPAL AFFAIRS AND HOUSING
BUILDING CODEACT, 1992 RULING OF THE MINISTER OF MUNICIPAL AFFAIRS AND HOUSING Pursuant to clause 29(l)(b) of the Building Code Act, 1992. as amended, the Director of the Building and Development Branch
More informationIntroduction to Energy Codes & Green Building Programs
Introduction to Energy Codes & Green Building Programs David Neiger B.S. Arch, LEED AP Homes, Certified HERS Rater Principal Populus Sustainable Design Consulting Why green homes? The Building Sector:
More informationEnergy Efficiency and Renewable Energy Sources in Sweden
Energy Efficiency and Renewable Energy Sources in Sweden Swedish Energy Agency www.stem.se Yelena Varasteh yelena.varasteh@stem.se Slovakia, 24-25 April 2006 Total energy supply in Sweden in 2004 Total
More informationHVAC Code Requirements
one and two family dwellings? Answer: SECTION 2001: GENERAL 2001.1 Air supply. Fuel-burning equipment shall be provided with a supply of air for fuel combustion, draft hood dilution and ventilation of
More informationSome Environmental and Economic Aspects of Energy Saving Measures in Houses
i ii UNIVERSITY OF TRONDHEIM THE NORWEGIAN INSTITUTE OF TECHNOLOGY FACULTY OF CIVIL ENGINEERING DEPARTMENT OF BUILDING AND CONSTRUCTION ENGINEERING Some Environmental and Economic Aspects of Energy Saving
More informationEnergy efficiency building standards in Japan
www.asiabusinesscouncil.org Energy efficiency building standards in Japan Japan s regulation of building energy efficiency falls under the Energy Conservation Law that was first adopted in 1979. Subsequently
More informationEnergy Optimisation of a Building: a Case Study of Ekebyvallen, Uppsala
TVE 13 022 Examensarbete 15 hp Juni 2013 Energy Optimisation of a Building: a Case Study of Ekebyvallen, Uppsala Profitable investments in a world with rising energy prices Pär Enarsson Otto Hedenmo Dirk-Jan
More information3. Good Practice Example: SEAP (Sustainable Energy Action Plan) (Budapest, Hungary)
3. Good Practice Example: SEAP (Sustainable Energy Action Plan) (Budapest, Hungary) Keywords Budapest, sustainable energy, CO2 emission reduction, climate protection, action plan Name and location Budapest
More informationBuilding Energy Codes 101 October 23, 2013. Matthew Giudice Building Policy Associate Midwest Energy Efficiency Alliance
Building Energy Codes 101 October 23, 2013 Matthew Giudice Building Policy Associate Midwest Energy Efficiency Alliance OVERVIEW 1. Introduction 2. Energy Code Development 3. Adoption Process 4. Elements
More informationA Carbon Footprint of an Office Building
Energies 2011, 4, 1197-1210; doi:10.3390/en4081197 OPEN ACCESS energies ISSN 1996-1073 www.mdpi.com/journal/energies Article A Carbon Footprint of an Office Building Miimu Airaksinen 1, * and Pellervo
More informationChallenging the possibilities
Passivhus Norden 2013 Challenging the possibilities Olav Langenkamp, Architect ETH-MAA, Langenkamp.dk Architects, Tigervej 26 8400 Ebeltoft Denmark, ol@langenkamp.dk Martin Wikkelsø Brandt, Cand. Polyt.
More informationRequirements to Obtain a Building Permit for a NEW HOME. 1. Completed application form. (Boxes A, B, C, D & E if applicable F and I)
Requirements to Obtain a Building Permit for a NEW HOME 1. Completed application form. (Boxes A, B, C, D & E if applicable F and I) 2. Proof of Ownership (New Development Only, Copy of Deed or Tax Bill)
More informationAnalysis of Energy Consumption, Rating Score, and House Size
Analysis of Energy Consumption, Rating Score, and Duncan Prahl, Registered Architect Innovation Programs Leader, Research and Development, IBACOS, Inc., Phone: + 1 412 325 1523. Fax: + 412 765 3738. E-mail:
More informationPassive house rehabilitation of post war residential building in Zug, Switzerland
Passive house rehabilitation of post war residential building in, Switzerland Owner: Erbengemeinschaft Ducret Architect: Miloni & Partner, Wettingen Energy concept designer: Zurfluh & Lottenbach, Luzern
More informationEnergy efficiency and excess winter deaths: Comparing the UK and Sweden
Westgate House 2a Prebend Street London N1 8PT 020 7359 8000 sarah@ukace.org Energy efficiency and excess winter deaths: Comparing the UK and Sweden November 2013 1 Introduction David Cameron pledged in
More informationTOWARDS NEARLY ZERO ENERGY BUILDINGS IN IRELAND PLANNING FOR 2020 AND BEYOND. Department of the Environment, Community and Local Government
TOWARDS NEARLY ZERO ENERGY BUILDINGS IN IRELAND PLANNING FOR 2020 AND BEYOND Department of the Environment, Community and Local Government November 2012 CONTENTS SECTION 1 GENERAL 1.1 Introduction 1.2
More informationExtra Low Energy Housing in Ireland How far should we go to the Passive House? Jonathan Jennings Head of R&D Kingspan Century Homes
Extra Low Energy Housing in Ireland How far should we go to the Passive House? Jonathan Jennings Head of R&D Kingspan Century Homes Current Status % CO 2 emissions Transport 30% Agriculture 2% Housing
More informationBuilding Permit Application
Building Permit Application CBO: Don Reed / Inspector: Scott Richardson -All applications must be filled out in full -Residential applications will be issued or denied within 10 working days -Multi-residential
More informationSolar urban planning. The National state of the art in Sweden
Solar urban planning The National state of the art in Sweden Entity Lund University Developers Elisabeth Kjellsson Date 2009-11-15 1 INDICE Solar urban planning...1 1. Political, Legal and economic framework...3
More information9 Energy management. 9:1 General. BFS 2011:26 BBR Oct. 9:11 Scope of application
BFS 2011:26 9 Energy management This section contains the provisions and general recommendations for Chapter 3, Article 14 and Chapter 3 the first paragraph of Article 15 of PBF. Section 9:9 contains provisions
More informationBackground material A United Kingdom Domestic Carbon Model (UKDCM) Description, method and analysis
40% House Project Background material A United Kingdom Domestic Carbon Model (UKDCM) Description, method and analysis 1. Introduction This document describes the main components of the computer-based UK
More informationPENNSYLVANIA GREEN ENERGY LOAN FUND
PENNSYLVANIA GREEN ENERGY LOAN FUND Procedures Manual for Quantifying Energy Savings A. Introduction A building project applying for a GELF energy loan must demonstrate that it will result in a 25% reduction
More informationClimate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi
Climate and Energy Responsive Housing in Continental Climates The Suitability of Passive Houses for Iran's Dry and Cold Climate Farshad Nasrollahi Table of Contents Abstract German Abstract Introduction
More informationExecutive Order amending the Executive Order on the Publication of the Danish Building Regulations 2010 (BR10) 1)
Full text Executive Order amending the Executive Order on the Publication of the Danish Building Regulations 2010 (BR10) 1) 1. The following amendments shall be made to Executive Order no. 810 of 28 June
More informationEco Fund s Financial Incentives for Energy Efficiency in Buildings
Eco Fund s Financial Incentives for Energy Efficiency in Buildings Alma Bijedić, Advisor to Eco Fund EPEC EE Workshop: Energy efficiency in Slovenia, Ljubljana 2013 About Eco Fund, Slovenian Environmental
More informationImproving thermal insulation of concrete sandwich panel buildings
Improving thermal insulation of concrete sandwich panel buildings Jørgen Munch-Andersen Danish Building Research Institute, Aalborg University LCUBE conference, Vienna 17-18 April 2007 Outline A general
More informationStatus and Priorities of Building Energy Efficiency in China Xudong Yang, Ph.D.
Status and Priorities of Building Energy Efficiency in China Xudong Yang, Ph.D. Chang-Jiang Professor and Deputy Director Institute of Built Environment, China Current situation of building energy consumption
More informationRadon in Nordic countries
Radon in Nordic countries Tarja K. Ikäheimonen Radiation and Nuclear Safety Authority Finland Outline Radon sources Health risk Radon concentrations Reference levels Radon remediation and prevention Radon
More informationECODESIGN by FLÄKT WOODS EU REGULATION 1253 AND 1254/2014 FOR RESIDENTIAL AND NON-RESIDENTIAL VENTILATION UNITS
ECODESIGN by FLÄKT WOODS EU REGULATION 1253 AND 1254/2014 FOR RESIDENTIAL AND NON-RESIDENTIAL VENTILATION UNITS ENVIRONMENT ECONOMICAL EXPERTISE In its simplicity the e 3 captures what makes us attractive
More informationSIP (STRUCTURAL INSULATED PANEL)
SIP (STRUCTURAL INSULATED PANEL) KINGSPAN TEK ACORN SIP ABSTRACT BUILDING SERVICES Ltd Kingspan TEK is the manufacturer and supplier of the panels and components. Acorn SIP are the Architects who individually
More informationA QUALITY ASSURANCE MANAGEMENT SYSTEM FOR RETROFITTING WITH GOOD INDOOR ENVIRONMENT AND ENERGY EFFICIENCY
A QUALITY ASSURANCE MANAGEMENT SYSTEM FOR RETROFITTING WITH GOOD INDOOR ENVIRONMENT AND ENERGY EFFICIENCY M.Sc. Svein Ruud, Dr. Åsa Wahlström and Dr. Kristina Mjörnell SP Technical Research Institute of
More informationReducing energy consumption in a historical school building
Reducing energy consumption in a historical school building Demonstration building within the EU project «School of the Future» and with Enova Geir Andersen, Drammen Eiendom KF Sverre Tangen, Glass og
More informationProposal of the Long-Term Strategy for Mobilising Investment in the Renovation of the National Building Stock of the Republic of Croatia
Republic of Croatia MINISTRY OF CONSTRUCTION AND PHYSICAL PLANNING Proposal of the Long-Term Strategy for Mobilising Investment in the Renovation of the National Building Stock of the Republic of Croatia
More informationRehabilitation Mas Thibert / Arles
Rehabilitation Mas Thibert / Arles Gonzague Descoqs Project manager 16th January 2012, Steering Committee Meeting, Malta 2 13 Habitat, short presentation Social housing organisation, based in Marseille
More informationBuilding Permit Application
Building Permit Application Front of Yonge Township Office 1514 County Road 2, P.O. Box 130 Mallorytown ON, K0E 1R0 Tel: 613-923-2251 Fax: 613-923-2421 admin@frontofyonge.com www.mallorytown.ca Last Updated
More informationNATURAL GAS IN COMMERCIAL BUILDINGS
OCTOBER 2012 TECHNOLOGY NATURAL GAS IN COMMERCIAL BUILDINGS Discussion Questions: 1. If natural gas promises lower operating costs, lower emissions, and greater efficiency over utility grid delivered electricity,
More informationEN 1279-5. Insulating glass units, intended to be used in buildings and construction works
4 (#2) - 12-4, Thermally Toughened Heat and Solar Control Glass 1 (C) 3-12 - 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,71/0,10/0,11 Solar energy characteristics
More informationBUILDING ENERGY EFFICIENCY. A Certification System for Building Efficiency ORTUGAL
BUILDING ENERGY EFFICIENCY A Certification System for Building Efficiency ORTUGAL ENERGY PERFORMANCE Portugal s certification system for buildings encourages efficiency Portugal has significant potential
More informationReport Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669
Report Date: 04/03/2014 Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669 About this Advisory Report Energy use in our homes is responsible for almost
More informationEuropean actions to improve the energy efficiency of buildings. Olli Seppänen, professor Federation of European Heating and Airconditioning
European actions to improve the energy efficiency of buildings Olli Seppänen, professor Federation of European Heating and Airconditioning Associations 1 Climate Action: Energy for a Changing World On
More informationNational Plan. Towards nearly zeroenergy. in The Netherlands. NL Agency. Ing. Hans van Eck Unit-Manager Housing sector.
To help protect your privacy, PowerPoint has blocked automatic download of this picture. National Plan Towards nearly zeroenergy buildings in The Netherlands Ing. Hans van Eck Unit-Manager Housing sector
More informationAlternatives for the Residential Energy Consumption Baseline
Alternatives for the Residential Energy Consumption Baseline Executive Summary. Should the baseline for energy consumption in the Northeast Neighborhoods development area be changed from the current citywide
More informationBuilding Control Guidance Note
Elements Renovation / Replacement. Issued 25/01/13 Rev a Page 1 of 9 (Applies to both Domestic and Non-Domestic Premises) Works relating to thermal elements can arise in building an extension, a material
More informationEnergy savings in the residential area are essential in
Overheating and insufficient heating problems in low energy houses up to now call for improvements in future Requirements for improved energy performance have shifted major focus on energy calculations
More informationEnergy Efficiency Approach for Buildings in Georgia: Energy Passport Software Program and Certification of Buildings
Energy Efficiency Approach for Buildings in Georgia: Energy Passport Software Program and Certification of Buildings Dr. K. Melikidze Director, Sustainable Development and Policy (SDAP) Center, Tbilisi,
More informationResidential HVAC Load Sizing Training October 14, 2015. David Kaiser Green Code Plan Reviewer
Residential HVAC Load Sizing Training October 14, 2015 David Kaiser Green Code Plan Reviewer DCRA - Green Building Division Regulations of green codes including: Green Building Act Green Construction Code
More informationRegulative Change Targeting Energy Performance of Buildings in Sweden
FNI Report 2/2009 Regulative Change Targeting Energy Performance of Buildings in Sweden Key Drivers and Main Implications Bente Beckstrøm Fuglseth Regulative Change Targeting Energy Performance in Buildings
More informationOEGNB - Open Source Building Assessment
OEGNB - Open Source Building Assessment Mag. Dr. Susanne Geissler SB13 26th September 2013 Graz ÖGNB sustainable building assessment/quality label The ÖGNB quality label is based on the TQB assessment
More informationThis document is downloaded from the Digital Open Access Repository of VTT. VTT http://www.vtt.fi P.O. box 1000 FI-02044 VTT Finland
This document is downloaded from the Digital Open Access Repository of VTT Title Energy saving potentials of Moscow apartment buildings in residential districts Author(s) Paiho, Satu; Hedman, Åsa; Abdurafikov,
More informationThe Potential for Energy Retrofits within the City of Sacramento s Rental Housing Inspection Program
PNNL-20343 Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 The Potential for Energy Retrofits within the City of Sacramento s Rental Housing Inspection Program MM Iverson S
More informationCITY PLAN REVIEW AND INSPECTION. Lisa Fleming Brown, CPM
CITY PLAN REVIEW AND INSPECTION Lisa Fleming Brown, CPM Houston Commercial Energy Conservation Code (2011) A choice of 2009 IECC or ASHRAE 90.1-2007 with amendments. Effective September 2, 2011. Complete
More informationPROBIS SUPPORTING PUBLIC PROCUREMENT OF BUILDING INNOVATIVE SOLUTIONS
PROBIS SUPPORTING PUBLIC PROCUREMENT OF BUILDING INNOVATIVE SOLUTIONS Regione Lombardia ALER Bergamo Lecco Sondrio Treviglio via Dei Mulini n. 10/20 via Filzi n. 11/13 Prospectus Template provided by TEH-Ambrosetti.
More informationHEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS
HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS Saim Memon Philip C. Eames Centre for Renewable Energy Systems
More information