COMMERCIAL BUILDING SYSTEMS & DATA
|
|
- Lucas Copeland
- 7 years ago
- Views:
Transcription
1 COMMERCIAL BUILDING SYSTEMS & DATA U34 LED and U33 indoor emergency lighting luminaires S8 indoor standard emergency lighting luminaires U21 indoor emergency lighting luminaires B66 LED, B66 and B55 weatherproof emergency lighting luminaires Safety portable lamps, spare parts and labels L31 indoor and Arcor 2 emergency lighting luminaires LVS2 addressable & monitoring system Conversion kits for normal lighting fixtures
2 LED maintained/ non maintained units High power LEDs with specially designed lens optimizing the lighting distribution IP 42 - IK 07 Class II Power supply: 230 V ± 10% - 50/60 Hz Very low consumption switching power supply Fully recyclable after removing Environment friendly Ni-MH batteries Removable plug-in plate to ease installation and maintenance Automatic terminals with high capacity: 2 x 2.5 mm² Charge monitor with a green LED Pack Cat.Nos Standard luminaires Standard luminaires incorporate an external manual lamp test 1 h duration with opal diffuser Maintained/Non maintained lm - 1h (LEDs) Maintained/Non maintained lm - 1h (LEDs) 3 h duration with opal diffuser Maintained/Non maintained lm - 3h (LEDs) Autotest/addressable luminaires Autotest/addressable luminaires incorporate an automatic self-testing system Tests result is visible on 2 signalling LEDs (green-ok and yellow-defective) Addressable function is activated by setting an ID on each luminaire with infrared configuration tool (Cat. No ) and wiring a complementary BUS line Operating state of all addressable luminaires can be centralized by the control interface (Cat. No ) and monitored on a local touch screen controller (Cat.No ), or with the building s plan on Legrand Vision System (L.V.S. 2) PC software 1 h duration with opal diffuser Maintained/Non maintained lm - 1h (LEDs) Maintained/Non maintained lm - 1h (LEDs) 3 h duration with opal diffuser Maintained/Non maintained lm - 3h (LEDs) Pack Cat.Nos Accessories Lateral cabling accessory for U33/U34LED plug-in plate Flush-mounting frame for dry partitions Flush-mounting box for masonry (to be added with flush-mounting frame) Vertical signalling plate (to be associated with signalling pictograms x 254 mm x 254 mm x 254 mm x 254 mm x 254 mm x 254 mm x 254 mm Infrared testing tool for U34 LED, U33, B66 LED and B66 standard luminaires 668 Red catalogue numbers: New products
3 , Installation Dimensions (in mm) Surface-mounting Surface-mounting mm 70 mm 125 Plug-in plate ,3 HAUT Flush-mounting in dry partitions TOP AC/DC TELEC 1 Lateral cabling accessory 3 100,4 A 28, A 4 Flush-mounting in masonry Flush-mounting in dry partitions , Flush-mounting with signalling plate Flush-mounting in masonry , Signalling plate 296,4 102,
4 W and PL11W fluorecent non maintained, maintained and combined units Certified to IEC and EN standards IP 42 - IK 07 Class II Power supply: 230 V ± 10% - 50/60 Hz Low consumption switching power supply Fully recyclable after removing Ni-Cd batteries Recharge time: 24 hours Plug-in plate to ease mounting and cabling Automatic terminals with high capacity: 2 x 2.5 mm² Charge monitor with a green LED Pack Cat.Nos Standard luminaires Standard luminaires incorporate an external manual lamp test 1 h duration with opal diffuser Non maintained lm - 1h (1 x 8W) Non maintained lm - 1h (1 x 8W) Non maintained lm - 1h (1 x 8W) Non maintained lm - 1h (1 x 11W) Maintained lm - 1h (1 x 8W) Combined lm - 1h (2 x 8W) 1 h duration with Fresnel lens transparent diffuser Non maintained lm - 1h (1 x 8W) Maintained lm - 1h (1 x 8W) Combined lm - 1h (2 x 8W) 3 h duration with opal diffuser Non maintained lm - 3h (1 x 8W) Maintained lm - 3h (1 x 8W) Combined lm - 3h (2 x 8W) Autotest/addressable luminaires Autotest/addressable luminaires incorporate an automatic self-testing system Tests result is visible on 2 signalling LEDs (green-ok and yellow-defective) Addressable function is activated by setting an ID on each luminaire with infrared configuration tool (Cat.No ) and wiring a complementary BUS line Operating state of all addressable luminaires can be centralized by the control interface () and monitored on a local touch screen controller (Cat.No ), or with the building s plan on Legrand Vision System (L.V.S. 2) PC software 1 h duration with opal diffuser Non maintained lm - 1h (1 x 8W) Non maintained lm - 1h (1 x 8W) Maintained lm - 1h (1 x 8W) Combined lm - 1h (2 x 8W) Combined lm - 1h (2 x 8W) 3 h duration with opal diffuser Non maintained lm - 3h (1 x 8W) Maintained lm - 3h (1 x 8W) Combined lm - 3h (2 x 8W) Pack Cat.Nos Accessories Lateral cabling accessory for U33/U34LED plug-in plate Flush-mounting frame for dry partitions Flush-mounting box for masonry (to be added with flush-mounting frame) Vertical signalling plate (to be associated with signalling pictograms x 254 mm x 254 mm x 254 mm x 254 mm x 254 mm x 254 mm x 254 mm Infrared testing tool for U34 LED, U33, B66 LED and B66 standard luminaires 670 Red catalogue numbers: New products
5 , Installation Dimensions (in mm) Surface-mounting Surface-mounting mm 70 mm 125 Plug-in plate ,3 HAUT TOP Flush-mounting in dry partitions AC/DC TELEC 1 Lateral cabling accessory ,4 A 28, A 4 Flush-mounting in masonry Flush-mounting in dry partitions Flush-mounting with signalling plate Flush-mounting in masonry , Signalling plate 342,4 102,
6 Dimensions (in mm) Optical data Distribution of luminous intensity in cd/1000 lm Surface mounting Luminaire spacing, in metres, to provide 1 lux minimum illuminance Cat.No Cat.No Pack Cat.Nos 8 W fluorescent non-maintained, maintained and combined units Certified to IEC and EN standards IP 42 Class II Power supply: 230 V +/- 10 % - 50/60 Hz Lamp and emergency operation test with a push-button Ni-Cd batteries Recharge time: 24 hours High capacity screw terminals: 2 x 2.5 mm 2 Charge monitor with a green LED 1 h duration lm Non maintained lm - 1h (1 x 8 W) Maintained lm - 1h (1 x 8 W) Combined lm - 1h (2 x 8 W) 3 h duration lm Non maintained lm - 3h (1 x 8 W) Maintained lm - 3h (1 x 8 W) Combined lm - 3h (2 x 8 W) Accessories Flush-mounting frame Double-sided diffuser Ceiling mounting with double-sided diffuser Flush-mounting With double-sided diffuser Lamps and batteries Cat.Nos Emergency lamps Batteries /01/ /04/ Ceiling mounting height (m) Lighting level directly under luminaire (lux) Axial to wall Axial spacing Transverse Transverse spacing to wall D (m) D (m) D (m) D (m) / / / / / / /5 3.2/ / / /5 2.8/ / / / / / / / / / / / / / / /4.3 2/ / / C0-C180 C45-C225 C0-C180 C45-C cd 50 cd C90-C270 C135-C C90-C270 C135-C C0-C180 C45-C225 C0-C180 C45-C cd Cat.No Cat.No cd C90-C270 C135-C Cat.No Cat.No C0-C180 C45-C cd C90-C270 C135-C C0-C180 C45-C cd C90-C270 C135-C C90-C270 C135-C
7 W fluorescent non-maintained and combined units Certified to IEC and EN standards IP 42 - IK 04 Power supply: 230 V± 10% Plug-in base to ease fixing, cabling and connection Transparent diffuser Duration time: 1, 2 and 3 hours Ni-Cd batteries Recharge time: 24 hours Green LED charge monitor High capacity screw terminals (2 x 2.5 mm 2 ) Flush mounting in dry partitions (ceiling): add flush mounting frame Cat.No Flush mounting in masonry (brick or concrete wall): add both flush mounting box Cat.No and flush mounting frame Cat.No Pack Cat.Nos Standard luminaires Non-maintained 6 W fluorescent luminaires Non maintained - 50 lm - 1h (1 x 6 W) Non maintained - 70 lm - 1h (1 x 6 W) Non maintained lm - 1h (1 x 6 W) Non maintained lm - 1h (1 x 6 W) Non maintained lm - 1h (1 x 6 W) Non maintained lm - 1h (1 x 6 W) Non maintained - 90 lm - 3h (1 x 6 W) Non maintained lm - 2h (1 x 6 W) Combined 2 x 6 W fluorescent luminaires Combined lm - 1h (2 x 6 W) Combined lm - 2h (2 x 6 W) Pack Cat.Nos Autotest/Addressable luminaires Autotest/addressable luminaires incorporate an automatic self-testing system Tests result is visible on 2 signalling LEDs (green-ok and yellow-defective) Addressable function is activated by setting an ID on each luminaire on internal microswitches with configuration tool (Cat.No ) and wiring a complementary BUS line Operating state of all addressable luminaires can be centralized by the control interface () and monitored on a local touch screen controller (Cat.No ), or with the building s plan on Legrand Vision System (L.V.S. 2) PC software Non-maintained 6 W fluorescent luminaires Non maintained lm - 1h (1 x 6 W) Non maintained lm - 1h (1 x 6 W) Non maintained lm - 1h (1 x 6 W) Non maintained lm - 1h (1 x 6 W) Non maintained lm - 3h (1 x 6 W) Combined 2 x 6 W fluorescent luminaires Combined lm - 1h (2 x 6 W) Combined lm - 3h (2 x 6 W) Accessories Flush mounting frame for dry partition Flush mounting box for masonry partition 674 Red catalogue numbers: New products
8 Surface mounting installation Flush-mounting cut-out in dry partitions A B Flush-mounting Flush-mounting cut-out in masonry Dimensions (in mm) Surface mounting
9 Pack Cat.Nos B66 LED LED maintained/non maintained weatherproof luminaires High power LEDs with specially designed lens optimizing the lighting distribution IP 66 - High protection level IK 10 - Very high resistance level against mechanical shocks Class II Power supply: 230 V + 10% - 50/60 Hz Very low consumption switching power supply Environment friendly Ni-MH batteries Recharge time: 24 hours Plug-in back with automatic high capacity terminals: 2 x 2.5 mm² Diffuser with tool-less fast mounting Charge monitor with a green LED Standard luminaires - 1 h duration with transparent diffuser Luminaires incorporate an external manual lamp test Maintained/Non maintained lm - 1h (LEDs) Maintained/Non maintained lm - 1h (LEDs) Maintained/Non maintained lm - 1h (LEDs) Autotest/Addressable luminaires - 1 h duration with transparent diffuser Autotest/addressable luminaires incorporate an automatic self-testing system Tests result is visible on 2 signalling LEDs (green-ok and yellow-defective) Addressable function is activated by setting an ID on each luminaire with infrared configuration tool (Cat.No ) and wiring a complementary BUS line Operating state of all addressable luminaires can be centralized by the control interface () and monitored on a local touch screen controller (Cat.No ), or with the building s plan on Legrand Vision System (L.V.S. 2) PC software Maintained/Non maintained lm - 1h (LEDs) Maintained/Non maintained lm - 1h (LEDs) Accessory Testing tool for U34 LED, U33, B66 LED and B66 standard luminaires Pack Cat.Nos B66 8 W and PL11 W fluorescent non maintained, maintained and combined luminaires Certified to IEC and EN standards IP 66 - High protection level IK 08 - High resistance level against mechanical shock Class II Power supply: 230 V + 10% - 50/60 Hz Low consumption switching power supply Ni-Cd batteries Recharge time: 24 hours Plug-in back with automatic high capacity terminals: 2 x 2.5 mm² Diffuser with tool-less fast mounting Charge monitor with a green LED Standard luminaires - 1 h duration with transparent diffuser Luminaires incorporate an external manual lamp test Non maintained lm - 1h (1 x 8 W) Non maintained lm - 1h (1 x 8 W) Non maintained lm - 1h (1 x 11 W) Maintained lm - 1h (1 x 8 W) Maintained lm - 1h (1 x 8 W) Combined lm - 1h (2 x 8 W) Combined lm - 1h (2 x 8 W) Standard luminaires - 3 h duration with transparent diffuser Luminaires incorporate an external manual lamp test Non maintained lm - 3h (1 x 8 W) Maintained lm - 3h (1 x 8 W) Combined lm - 3h (2 x 8 W) Autotest/Addressable luminaires - 1 h duration with transparent diffuser Autotest/addressable luminaires incorporate an automatic self-testing system Tests result is visible on 2 signalling LEDs (green-ok and yellow-defective) Addressable function is activated by setting an ID on each luminaire with infrared configuration tool (Cat.No ) and wiring a complementary BUS line Operating state of all addressable luminaires can be centralized by the control interface () and monitored on a local touch screen controller (Cat.No ), or with the building s plan on Legrand Vision System (L.V.S. 2) PC software Non maintained lm - 1h (1 x 8 W) Non maintained lm - 1h (1 x 8 W) Non maintained lm - 1h (1 x 11 W) Maintained lm - 1h (1 x 8 W) Maintained lm - 1h (1 x 8 W) Combined lm - 1h (2 x 8 W) Combined lm - 1h (2 x 8 W) Accessory Infrared testing tool for U34 LED, U33, B66 LED and B66 standard luminaires 676 Red catalogue numbers: New products
10 B66 LED - Dimensions (in mm) W and PL 11 W fluorescent non-maintained and combined units Certified to IEC and EN standards IP 55 - IK 07 Class II Power supply: 230 V+ 10% Plug-in base to ease fixing, cabling and connection Transparent diffuser Duration time: 1 and 2 hours Ni-Cd batteries Recharge time: 24 hours Green LED charge monitor High-capacity screw terminals (2 x 2.5 mm²) 3 flexible cable entries for Ø16, 20 and 25 mm tubes B66 - Dimensions (in mm) Pack Cat.Nos Standard luminaires Non-maintained 6 W and 11 W fluorescent luminaires Non maintained lm - 1h (1 x 6 W) Non maintained lm - 1h (1 x 6 W) Non maintained lm - 1h (1 x 6 W) Non maintained lm - 1h (1 x 11 W) Non maintained lm - 2h (1 x 11 W) Combined 2 x 6 W fluorescent luminaires Combined lm - 1h (2 x 6 W) Combined lm - 1h (2 x 6 W) Autotest/Addressable luminaires Autotest/addressable luminaires incorporate an automatic self-testing system Tests result is visible on 2 signalling LEDs (green- OK and yellow-defective) Addressable function is activated by setting an ID on each luminaire on internal microswitches with configuration tool (Cat.No ) and wiring a complementary BUS line Operating state of all addressable luminaires can be centralized by the control interface (Cat.No ) and monitored on a local touch screen controller (Cat.No ), or with the building s plan on Legrand Vision System (L.V.S. 2) PC software Non-maintained 6 W and 11 W fluorescent luminaires Non maintained lm - 1h (1 x 6 W) Non maintained lm - 1h (1 x 6 W) Non maintained lm - 1h (1 x 6 W) Non maintained lm - 1h (1 x 11 W) Non maintained lm - 2h (1 x 11 W) Combined 2 x 6 W fluorescent luminaires Combined lm - 1h (2 x 6 W) Combined lm - 1h (2 x 6 W) B55 - Surface-mounted installation A B B55 - Dimensions (in mm) Red catalogue numbers: New products 677
11 Safety portable lamps Dimensions (in mm) Cat.No Cat.No Pack Cat.Nos LED maintained/non maintained weatherproof luminaires High power LEDs with specially designed lens optimizing the lighting distribution Power supply 230 V +/- 10% 50/60 Hz Very low consumption switching power supply Environment friendly Ni-MH batteries Recharge time: 24 hours IP66 plastic/stainless steel industrial & architectural luminaires - Autotest/addressable Maintained/non maintained lm - 1 h (LEDs) Maintained/non maintained lm - 3 h (LEDs) IP66/67 explosion-proof luminaires Autotest/addressable Complying to ATEX - 94/9 EC Directive and standards EN (gas - zones 1 & 2, dust - zones 21 & 22) Complying to IEC standards /1 Class of use: Ex d II C T Maintained/non maintained lm - 1 h (LEDs) Maintained/non maintained lm - 3 h (LEDs) NEW Safety portable lamps Supplied complete with built-in battery pack and charger When plugged into a mains socket, operate as safety lighting by switching on when there is a mains failure LED to indicate mains presence Mains connection lead also supplied 230 V± supply Plastic halogen lamps Duration: 3 hours 2 switches - 5 operating positions (steady beam, flashing beam, steady pilot lamp, flashing pilot lamp, stop) Battery level indicator with LEDs Class II IP W halogen lamp IP W halogen lamp Swivelling base plate Delivered with 4 colour screens (Red, green, orange, blue) 678
12 Pack Cat.Nos Lamps and tubes Lamps - E V A - 3 W (E 10) V A W (E 10) V - 1 A W (E 10) Tubes W W W Nickel - Cadmium batteries According to IEC V - 4 Ah V - 4 Ah V Ah V Ah V Ah V Ah V Ah V - 4 Ah V Ah V Ah V Ah Nickel metal-hydride batteries V Ah (Ni-MH) Pack Cat.Nos Labels Conform to CEE and ISO x 26 mm x 90 mm x 90 mm x 90 mm x 45 mm x 90 mm x 45 mm x 109 mm x 109 mm x 109 mm x 112 mm x 112 mm x 112 mm x 112 mm x 112 mm x 112 mm x 112 mm x 112 mm x 112 mm Red catalogue numbers: New products 679
13 Technical characteristics, see e-catalogue Pack Cat.Nos 6 W non-maintained environmental friendly extra slim luminaires Low depth: 43 mm Certified to IEC and EN standards Power supply: 230 V +/- 10% - 50/60 Hz Very low consumption with switching power supply incorporated IP 42 - IK 07 Class II Ni-MH environment friendly batteries Standard luminaires Non maintained lm - 1h (1 x 6 W) Non maintained lm - 1h (2 x 6 W) Non maintained lm - 2h (1 x 6 W) Non maintained lm - 1h (2 x 6 W) Autotest/Addressable luminaires Non-maintained autotest/addressable luminaires incorporate an automatic self-testing system Tests result is visible on 2 signalling LEDs (green-ok and yellow-defective) Addressable function is activated by setting an ID on each luminaire on internal microswitches with configuration tool (Cat.No ) and wiring a complementary BUS line Operating state of all addressable luminaires can be centralized by the control interface () and monitored on a local touch screen controller (Cat.No ), or with the building s plan on Legrand Vision System (L.V.S. 2) PC software Non maintained lm - 1h (2 x 6 W) Non maintained lm - 2h (1 x 6 W) Accessories Universal flush-mounting frame for walls and ceilings Includes 2 pieces: box + frame Flush-mounting frame for mounting over C3 range box For access with tubes 20 mm Pictogram plate for transformations in a double side unit Square diffuser Round diffuser Round flush-mounting frame Square flush-mounting frame Pack Cat.Nos 6 W non-maintained and combined extra slim luminaires Low depth: 43 mm Certified to IEC and EN standards Z Low consumption with switching power supply incorporated IP 42 - IK 07 Class II Ni-Cd batteries Autotest/addressable luminaires incorporate an automatic self-testing system Tests result is visible on 2 signalling LEDs (green-ok and yellow-defective) Addressable function is activated by setting an ID on each luminaire on internal microswitches with configuration tool (Cat.No ) and wiring a complementary BUS line Operating state of all addressable luminaires can be centralized by the control interface () and monitored on a local touch screen controller (Cat.No ), or with the building s plan on Legrand Vision System (L.V.S. 2) PC software Standard luminaires Power supply: 230 V +/- 10% - 50/60 Hz Non maintained - 70 lm - 1h (1 x 6 W) Non maintained lm - 1h (1 x 6 W) Non maintained lm - 1h (1 x 6 W) Non maintained lm - 1h (1 x 6 W) Non maintained - 75 lm - 3h (1 x 6 W) Combined lm - 1h (2 x 6 W) Combined lm - 2h (2 x 6 W) Standard luminaires Power supply: from V - 50/60 Hz Non maintained lm - 1h (1 x 6 W) Non maintained lm - 1h (1 x 6 W) Non maintained - 75 lm - 3h (1 x 6 W) Autotest/Addressable luminaires Power supply: 230 V +/- 10% - 50/60 Hz Non maintained lm - 1h (1 x 6 W) Non maintained lm - 1h (1 x 6 W) Combined lm - 1h (2 x 6 W) Combined lm - 2h (2 x 6 W) Autotest/Addressable luminaires Power supply: from V - 50/60 Hz Non maintained lm - 1h (1 x 6 W) 680
14 Dimensions (in mm) Universal surface mounting With round diffuser With pictogram plate Flush-mounting with round diffuser Universal flush-mounting to With square diffuser Ø Flush-mounting with square diffuser Mounting with tubes 20 mm to Lamps and batteries Cat.Nos Emergency lamps Batteries /19/ /20/31/ / / / / / to
15 environments fl ush-mounting Equipped with long-life cold cathode fl uorescent tube (> 50,000 hours) Certifi ed to IEC and EN standards Lumen output: 45 lumens Duration: 1 hour IP 20 - class II Power supply 230 V± - 50/60 Hz Autotest luminaires incorporate an automatic self-testing system Tests result is visible on 2 signalling LEDs (green-ok and yellow-defective) Unit for direct fl ush-mounting: - on self-supporting ceilings using quick-fi t fi xing claws - on false ceilings using holding claws and fastening system for safety tie or by 1/4 -turn for threaded rod Shallow depth (80 mm) Option of mounting as wall strip or flag with fixing kit Cat.No / Direct flush-mounting Wall or flag mounting Pack Cat.Nos Autotest luminaires Maintained - 45 lm - 1h (CCFL) Non maintained - 45 lm - 1h (CCFL) Equipped with long life LED standby indicator (> 100,000 hours) Autotest/Addressable luminaires Addressable function is activated by setting an ID on each luminaire on internal microswitches with confi guration tool (Cat.No ) and wiring a complementary BUS line Operating state of all addressable luminaires can be centralized by the control interface () and monitored on a local touch screen controller (Cat.No ), or with the building s plan on Legrand Vision System (L.V.S. 2) PC software Maintained - 45 lm - 1h (CCFL) Non maintained - 45 lm - 1h (CCFL) Equipped with long life LED standby indicator (> 100,000 hours) Fixing kit for mounting as wall strip or flag Kit comprising: - 1 mounting bracket - 1 casing Aluminium fi nish White fi nish 682
16 Overall dimensions Standard flush-mounting mm Pack Cat.Nos Pictogram plates 280 Polycarbonate plates directly moulded with the pictogram (In-Mold technology) ensuring improved luminous performances and protection against scratches Complying with ISO and ISO 7010 standards For emergency lighting Exit to left or right Wall mounting with fixing kit Flag mounting mm Exit below Flush-mounting Flag mounting Wall strip mounting 683
17 Pack Cat.Nos Control interface for autotest/addressable luminaires Centralises the operating state of addressable emergency lighting luminaires Communication between the addressable luminaires and the control interface is carried out via a BUS line Direct connection of 250 addressable luminaires to the control interface (star configuration or series connection) The longest line is limited to 700 m Extension via repeater Cat.No for more than 250 addressable luminaires or a line longer than 700 m Maximum capacity of the central control panel: 1023 addressable luminaires Configuration software included (control interface settings and ID configuration for addressable luminaires) To be completed with at least one of the following terminals: - PC with monitoring software Cat.No Touch screen controller Cat.No PC with internet navigator (limited functions) - RJ 45 socket for IP network - terminals for RS 232 and RS Mini USB for PC local settings VA - 50/60 Hz - Ni-Cd battery: 8.4 V Ah Mobile infrared configuration tool For assigning an ID to each addressable luminaire in order to control operating state with control interface Pack Cat.Nos 3.5" touch screen controller For controlling the operating state of a global addressable luminaires installation To be used complementary to the control interface Connected to the control interface through IP infrastructure Display of: - defect type - defect units location Alarms and operating mode settings power supply voltage: 27 V ma with a separate power supply Cat.No To be equipped with white plate Cat.No or aluminium plate Cat.No (support) To be mounted in flush-mounting box Cat.No Monitoring PC software For supervising an installation equipped with addressable self-contained emergency lighting luminaires and control interface(s) Cat.Nos , whatever the installation size Simultaneous monitoring of an establishment, made of several buildings, according to the construction configuration (tree structure by buildings, levels, floors or zones) Overview screen of the luminaires installation operating state Functions for maintenance assistance: - Automatic printout of the spare parts list - Automatic printout of a maintenance document locating each defect luminaire and detailing the repair operations Repeater For extending the installation beyond 250 units or for a line > 700 m (on control interface or repeater) up to 250 additional luminaires and on the longest line < 700 m Class II Power supply: 230 VA - 50/60 Hz Ni-Cd battery: 8.4 V Ah Dim.: 6 x 17.5 mm modules Additional power supply Power supply V - 50/60 Hz Output V= ma Dim.: 2 x 17.5 mm modules 684 Red catalogue numbers: New products
18 Addressable and monitoring system Installation and configuration Setting of an ID on each luminaire with infrared configuration tool Wiring Control interface Line: 700 m max. Addressable emergency lighting luminaire 250 luminaires max. beyond 250 units, use a repeater Mobile infrared configuration tool Cat.No Installation checking Repeater Cat.No Addressable emergency lighting luminaire Control interface capacity: 1023 luminaires PC connection to control interface(s) through RS 485 serial BUS Control interface External interface RS 485 RS 232 / USB... or PC memory stick PC Technical room Control interface Control interface Bus RS wires duplex or 2 wires half duplex Monitoring Centralization operating state Addressable emergency lighting luminaire Addressable emergency lighting luminaire PC connection to control interface through RS 232 serial line Control interface 5 m max. Câble de liaison femelle/femelle Type null modem PC Control interface PC connection to control interface through Ethernet network Control interface Technical room 3.5" touch screen controller Cat.No PC monitoring software Cat.No Local LAN Control interface dimensions (in mm) 67.2 Control interface PC equipped with an Ethernet card
19 To convert one fluorescent normal lighting source into an emergency lighting source Able to operate either on maintained or non-maintained mode Made up with a slim charger/inverter module and a battery pack designed to fit fluorescent luminaires Certified to EN standard (Z Cat.Nos /42/46/48, } other Cat.Nos) Operating ambient temperature: 10 C to 40 C Suitable for incorporation into luminaires with internal temperature up to 50 C To be installed apart in a remote box above 50 C Ni-Cd batteries Recharge time: 24 h Charge monitor with a green LED Pack Cat.Nos Standard conversion kits 1 h duration V - 50/60 Hz - For all lamps 1/ For 6 to 36 W lamps 1/ For 6 to 58 W lamps (high efficiency) 1/ For 6 to 58 W lamps 1 h duration V - 50/60 Hz - For all lamps except T5 tubes 1/ For 10 to 18 W lamps 1/ For 13 to 38 W lamps 1/ For 26 to 58 W lamps 1 h duration V - 50/60 Hz - For T5 lamps (with electronic ballasts only) 1/ For 14 to 24 W lamps 1/ For 28 to 54 W lamps Pack Cat.Nos Standard conversion kits (continued) 3 h duration - 230/240 V - 50/60 Hz - For all lamps 1/ For 6 to 58 W lamps 3 h duration - 230/240 V - 50/60 Hz - For all lamps except T5 tubes 1/ For 10 to 18 W lamps 1/ For 13 to 38 W lamps 1/ For 26 to 58 W lamps 3 h duration - 230/240 V - 50/60 Hz - For T5 lamps (with electronic ballasts only) 1/ For 14 to 24 W lamps 1/ For 28 to 54 W lamps 686 Bold pack quantities: Minimum quantities to be ordered
20 Dimensions Cat.Nos /42/46/48 Module Cat.Nos /76/77 Module Between holes: Battery Battery B A C D A B C Cat.Nos A B C D Cat.Nos A B C Battery type Stick 4 VTCs Stick 5 VTCs Stick 3 VTCs Stick 4 VTCs Cat.Nos /71/72 Module Cat.Nos /79 Module Between holes: Between holes: Battery Battery A B A B Cat.Nos A B Battery type Stick 3 VTD Stick 4 VTD Stick 5 VTD Cat.Nos A B Battery type Sticks 4 VTCs Stick 5 VTS Stick 6 VTS Cat.Nos /74 Module 30 Between holes: Battery A B C Cat.Nos A B C D Stick 4 VTD x Sticks 3 VTD 687
21 Ballast lumen (BLF) selection chart BLF (Ballast Lumen Factor) BLF (Ballast Lumen Factor) Lamp Wattage T8 18 W W W T5 14 W W W W W 0.17 (4) 0.23 (4) 49 W (4) 0.17 (4) 54 W (4) 0.14 (4) PLC 10 W W W W PLL 18 W W (2) 0.23 (2) W (2) 0.20 (1) W 0.18 (3) W 0.13 (3) PLT 18 W W W W D 10 W 0.40 (1) W 0.48 (1) 0.90 (2) 0.42 (2) W (2) 0.33 (2) W (2) 0.28 (2) W W C 22 W W W (1) 0.19 (2) : Autonomy > to 1h30 2: Autonomy > to 1h45 3: Autonomy > to 45 min 4: It's necessary to remove the switch Batteries Cat.Nos Battery type Battery specification Ni-Cd 6.0 V Ah Legrand_Emergency_Lighting_en_0712.pdf Ni-Cd 7.2 V - 4 Ah Ni-Cd 3.6 V - 4 Ah Ni-Cd 7.2 V - 4 Ah Ni-Cd 3.6 V - 4/4.5 Ah Ni-Cd 4.8 V - 4/4.5 Ah Helsinki tel automation@klinkmann.fi St. Petersburg tel klinkmann@klinkmann.spb.ru Moscow tel moscow@klinkmann.spb.ru Ni-Cd 6.0 V - 4/4.5 Ah Ni-Cd 4.8 V - 4/4.5 Ah Ni-Cd 7.2 V - 4/4.5 Ah Ni-Cd 4.8 V - 1.5/1.6 Ah Yekaterinburg tel yekaterinburg@klinkmann.spb.ru Samara tel samara@klinkmann.spb.ru Кiev tel klinkmann@klinkmann.kiev.ua Ni-Cd 6.0 V - 1.5/1.6 Ah Ni-Cd 8.4 V - 1.5/1.6 Ah Ni-Cd 9.6 V - 1.5/1.6 Ah Ni-Cd 13.2 V - 1.5/1.6 Ah Riga tel klinkmann@klinkmann.lv Vilnius tel post@klinkmann.lt Tallinn tel klinkmann.est@klinkmann.ee Мinsk tel minsk@klinkmann.com 688
93.68/93.69. Time scale: from 0.1s to 6h Multi-function For use with 34.51 (EMR) and 34.81 (SSR) relays. Screw terminal and push-in terminal
Series - Timed socket for 34 series Features.68/.69 Slim timed sockets for 34 series, 6.2 mm wide Timer adjustment via top mounted rotary knob accessible after assembly Control signal terminal DIP-switch
More informationSolid as a rock Soliroc
Solid as a rock Soliroc SOLUTIONS FOR EXPOSED OR UNSUPERVISED ENVIRONMENTS Think Soliroc for strength and design in exposed areas at the mercy of vandals and other abuse. The IK 10 Soliroc TM guarantees
More informationLUMOTAST 25. ø 16.2 mm 1 NO 35 V / 0,02 V. 100 ma / 0,1 ma. Flat-ribbon cable with connector, PCB socket IP 65. Bi-Pin T1/T1¼. Filament lamp, LED
Pushbuttons 8 mm Series LUMOTAST FK LUMOTAST 25 LUMOTAST 75 Keylock switch Other Pushbuttons Panel cut-out ø 8.1 mm ø 9.1 20.3 mm Contacts 1 NC +, 2 NC + 2 NO 1 4 NO 1 NC,, 1 NC +, 2 NC Contact material
More informationRobust and waterproof
K2 1 2 Safe in public rooms Safe in environments with high levels of humidity and high dust concentrations Safe in outdoor applications 3 Robust and waterproof K2 is a dust and waterproof (IP65) luminaire
More information2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design
.8 Ex-Recess-mounted, ceiling emergency light fittings in compact metal design RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX 50... N 18-36 W (Zone 1,, 1, ) The explosion-protected lighting concept for clean rooms
More informationEmergency Lighting Introduction
Emergency Lighting Introduction Introduction Emergency evacuation lighting is designed to automatically provide adequate lighting levels and signage for the safe evacuation of humans from buildings in
More informationMureva Assembly surface mounted wiring devices
1.0 Waterproof Assembly surface Switches P124543 P124547 External dimensions : 72 x 72 x 47 mm.. Assembly surface rockers become illuminated using bulbs and indicators in option. They can carry a label
More informationEXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications
EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin
More informationBatibox TM flush-mounting boxes for dry partitions
flush-mounting boxes for dry partitions 800 51 800 42 800 53 800 54 800 42 + 800 71 800 77 Cat.Nos 1-gang boxes For 1 module 20 800 40 Drilling diameter 32 mm Depth 40 mm For 1 gang or 2 modules For wiring
More information7 Lighting Technology
7 Lighting Technology Series HS6145 For use in Zone 1 and Zone 2 Comply with requirements of Fire Department standard DIN 14 462 Battery state display Deep discharge protection Open circuit monitor Light
More informationCOMPALARM AP GENERAL MAIN FEATURES
GENERAL The COMPALARM AP is a point alarm system, with as many normally closed input contacts. It givesthe possibility of selecting the alarm sequence according with 0 x 0 mm cells, fitted with ultra bright
More informationEXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES
EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES Gas explosion protection II 2G Ex d IIC T6 Gb (suitable for Zone1 and Zone 2) Dust explosion protection II 2D Ex tb IIIC
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationHCR3.2/.. Chipcard reader HOTEL SOLUTION
s 6 332 HOTEL SOLUTION Chipcard reader HCR3.2/.. Chipcard reader for hotel room access control Reads access code on chipcard Transfers access code to room controller Built-in optical display of messages
More informationDuroSite TM High Bay Lighting
DuroSite TM High Bay Lighting LED White Lighting Brochure for Industrial Applications CE version Application: The first of its kind, the Dialight DuroSite TM LED High Bay luminaire was designed specifically
More information2013 Wireless Video Intercom INSTALLATION GUIDE
2013 Wireless Video Intercom INSTALLATION GUIDE INDEX System configuration and wiring VL-SWD501 System Component.. 4 VL-SWD501EX wiring schematic diagram VL-SWD501EX wiring type and length... 5.... 6 Door
More informationProduct and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
More informationVoltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
More informationIndustrial Linergy LED
Eaton s commitment to supplying energy saving innovative products is the driving force behind. follows in the tradition of highly efficient large space luminaires which have the performance and flexibility
More information(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently
(68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please
More informationFIREDEX 2200. Conventional Fire Panels
68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class
More informationH45 LED - Direct and indirect pendant
RAL 01 10 00 IP 20 230V 50/60Hz Specifications Direct and indirect light pendant linear luminaire. Aluminium profile. Diffusers in frosted polycarbonate profile. Driver included. Supplied with clear base,
More informationHow To Use A Power Supply On A Powerline 2.2 (Ai)
KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang
More informationHMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB
Product datasheet Characteristics HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB Main Range of product Product or component type Display colour Display size Supply Magelis
More informationRemote Control Repeater
Remote Control Repeater Model: 40430 Operation Manual Ver.1.0 Operation Manual Remote Control Repeater Model: 40430 Thank you for purchasing Remote Control Repeater. We recommend that you read this manual
More informationRESOLUX / HIGHLITE/ COMPACT LINE Technology Lighting as its best. Designed and produced in Germany
RESOLUX / HIGHLITE/ COMPACT LINE Technology Lighting as its best. Designed and produced in Germany RESOLUX 505 RESOLUX 650 RESOLUX 720 / 730 / 750 Application Suitable for high switching frequencies as
More informationRemote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More informationLighting Management solutions
Lighting Management solutions Best practice guide for office buildings PUTTING A STOP TO ENERGY WASTE INTRODUCTION Table of contents 1 Lighting control Best Practice Guide for Office Buildings 2 Guide
More informationEnergy Communication Unit (ECU)
Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.8) ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2 2.0 Installation...
More informationA project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
More informationEMERGENCY LIGHTING - UCL GENERAL DESIGN GUIDANCE
Fire Safety Technical Guide EMERGENCY LIGHTING - UCL GENERAL DESIGN GUIDANCE Reference: A. British Standard 5266-1 Emergency Lighting - Code of Practice for the emergency lighting of premises; B. BS 5266-7
More informationD45. SySTEm. ThE high-performance
D45 ThE high-performance SySTEm Security monitoring system with digital BUS technologies High efficiency system and quick installation for both backbone and riserdevicesthankstotheuse of cat.5e UTP cables
More informationOperating Instructions
Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
More informationsensors Miniature Sensors - S100 The universal miniature photoelectric sensor
Miniature Sensors - S1 The universal miniature photoelectric sensor Two threaded front mounting holes Two slotted rear mounting holes Anti-tampering sensor (no adjustment) Standard optic functions and
More informationCompact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications
Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up
More informationAIS750 Series Alarm Annunciator
Unparallel, modular, multipoint design with Integrated controllers Two Operation Modes (Stand-alone & Serial) All sizes confi gurable up to 440 Alarm Points RS485 / RS232 Serial Communication Manual &
More informationWatertight Luminaire, surface, 1x18W / 2x18W / 2x24W / 1x36W / 2x36W / 2x54W
Watertight Luminaire, surface, 1x18W / x18w / x4w / 1x36W / x36w / x54w IP67 00 cd/klm 18W 36W 30V/ 50/60Hz 1x18W 5105 0005..-xxx.8 x18w 5105 0001..-xxx 3.8 x4w 5105 0045..-xxx 3.0 x54w 5105 0044..-xxx
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationAUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS
AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS 1 DORANI VIDEO INTERCOM - 2 WIRE SERIES 7 TFT MONITOR TECHNICAL SPECIFICATIONS 7 Colour TFT screen 480 x
More informationHMI display Installation Guide
HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC
More informationDECORATIVE RANGES PENDANTS FLUSH FITTINGS WALL LIGHTS TABLE & FLOOR BATHROOM SPOTLIGHTS & DOWNLIGHTS LED STRIPLIGHTS OUTDOOR LED LIGHTING
DECORATIVE RANGES PENDANTS FLUSH FITTINGS WALL LIGHTS TABLE & FLOOR BATHROOM SPOTLIGHTS & DOWNLIGHTS LED STRIPLIGHTS OUTDOOR LED LIGHTING LOW ENERGY LIGHTING LAMPS 149 Storm LED 8383 3 light flush Dedicated
More informationACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION
ACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION 2014 Ferport/Armas has over 30 years been synonymous with technology, reliability and experience in
More informationTemperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
More informationAppearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.
ZFX-C/25-CD Easy Vision Touch, Connect & Go Easy vision intuitive teach & go user interfaces Live built-in LCD touch monitors for setup and iediate feedback Counication centralized setup & inspection via
More informationIVIOS LED III. LUM Technical Information
LUM Technical Information Extremely flat high power LED downlights with splashing water protection (IP44). Ideal for substituting traditional CFL and halogen downlights with wide beam angle. Tender text
More informationFloodlight Range Installation Guide
SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected
More informationProgrammable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
More informationCombi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
More informationYour remote sites at your fingertips?
www.klinkmann.com Your remote sites at your fingertips? Industrial M2M Router & Data gateway The ewon is the first industrial modular M2M router and data gateway designed for OEMs and system integrators.
More informationEmergency Light Fittings
Emergency Light Fittings SCHUCH Emergency Light Fittings NEW NEU 164 218/25.. Dustproof/waterproof emergency light fitting for wind power stations. Description Series Page Polyester with Diffuser Insulation
More informationLinkeo 19" freestanding cabinets
87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3
More informationSecurity. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000
Security Alarm Central Unit 3 4 Technical KNX Alarm central unit EAM 4000 ETS-product family: Alarm system Product type: Alarm central unit The alarm central unit is a modern alarm system using the KNX
More informationSento LED parete singolo up cutsheet
0.2m Sento LED parete singolo up cutsheet LED wall mounted luminaire with a high base, in which the power supply unit (converter) is included for mounting on fixed ceiling or wall, connection to 230V.
More informationClear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
More informationPAR56 RGB 1.11 WIRELESS LAMP
LUMIPLUS PAR56 LAMP Install a lamp in the range LumiPlus 1.11 every 20 m 2 of water surface. Install a lamp in the range LumiPlus 2.0 every 20 m 2 of water surface. PAR56 1.11 LAMP Code flux RGB 56001
More informationDECORATIVE RANGES PENDANTS FLUSH FITTINGS WALL LIGHTS TABLE & FLOOR BATHROOM SPOTLIGHTS & DOWNLIGHTS LED STRIPLIGHTS OUTDOOR LED LIGHTING
DECORATIVE RANGES PENDANTS FLUSH FITTINGS WALL LIGHTS TABLE & FLOOR BATHROOM SPOTLIGHTS & DOWNLIGHTS LED STRIPLIGHTS OUTDOOR LED LIGHTING LOW ENERGY LIGHTING LAMPS 185 LED Fixed Fixed Colour Flexi Colour
More informationCombi B Alarm box. Mounting instructions
Combi B Alarm box Mounting instructions EN Mounting instructions Alarm box Combi B VdS, G113064, G113065, G113066 Table of Contents 1 Description... 3 2 System overview... 3 3 Structure... 3 3.1 Power
More informationSENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression
Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output
More informationLIGHTING FOR KITCHENS / UTILITY ROOMS / WORKSHOPS / KITCHEN CABINETS / GLASS CABINETS / FURNITURE
Lighting Catalogue 2005 LIGHTING FOR BATHROOMS / SHOWER ROOMS / DRESSING ROOMS / BEDROOMS ELITE 04 ELAN 06 ALL INSULATED 08 CSL SHAVER LIGHT 10 RAZORLITE 12 SWIFT 14 OPALITE 16 MULTILIGHT 18 RITZ MIRROR
More informationRISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
More informationDrayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
More informationAppearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.
ZFX-C10/15-CD Easy Vision Touch, Connect & Go Easy vision intuitive teach & go user interfaces Live built-in LCD touch monitors for setup and iediate feedback Counication centralized setup & inspection
More informationKIT DOWNLIGHT HALOSPOT 111 ES
LUM Technical Information Professional Downlight with innovative Energy Saver technology Availability: 4 weeks to order A: Product benefits Complete Kit for simple installation 16 Kit versions High-intensity
More informationLANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX
LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX The Lantana Luminaire linear light fixture is designed to seamlessly integrate with compatible Lutron control systems. It can be easily
More informationLighting Packages. 230 VAC Fluorescent Enclosure Light:
Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for
More informationG H I J K G DIMMING. QS no dimming 1 0. (10%) 3-wire hot dim EcoSystem (10%) digital dim U 0 Mark 7 (1% HO 5% HE) 0-10 V M 0 Mark 10 (1%) hot dim N 0
TUBO 150 T5 Date Project Type Quantity Contact/phone Product Description 6" diameter surface mounted or suspended extruded aluminum profile, powder coated white. Endcaps made of solid aluminum, available
More informationInwall 4 Input / 4 Output Module
Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...
More informationThe Foundation User Manual LED Battery Slim Par Fixture (RGBA, DMX 7Ch/4CH)
The Foundation User Manual LED Battery Slim Par Fixture (RGBA, DMX 7Ch/4CH) Page 1 I. Security: 1. Make sure the user voltage cannot higher or lower than the regulating voltage. 2. Please use proper and
More informationDlp-s & WIRING DEVICES. THE MAXIMUM FReeDOM OF ChOICe. SNAP-ON AND UNIVERSAL TRUNKING FOR high AND LOW CURReNt DIStRIBUtION
Dlp-s & WIRING DEVICES THE MAXIMUM FReeDOM OF ChOICe SNAP-ON AND UNIVERSAL TRUNKING FOR high AND LOW CURReNt DIStRIBUtION the global specialist IN electrical AND DIGItAL BUILDING INFRAStRUCtUReS Be free
More informationAlliance System Ordering Guide
Alliance System Ordering Guide Multiple Technologies Versatile Hardware Powerful Software One family of parts and accessories Version 12-Nov-03 Alliance System Ordering Guide Table of Contents Controllers
More informationFIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10
TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified
More informationAutomation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
More informationAlarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6
Alarm over IP IRIS Touch Home Installation Manual Version 1.0 ENGLISH Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6 1. Introduction No more bulky batteries, just one sleek unit
More informationHID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications
Applications Powerful, efficient floodlights for large areas such as industrial complexes and ship loading areas. Rated for use in hazardous areas. Features Highly efficient, integrally ballasted floodlight.
More informationLED Sign Module. LED Super Tiny Strip. LED Accessories. LED Power Supply
LED Sign Module LED Super Tiny Strip LED Accessories LED Power Supply April 2016 LED WATERPROOF MODULE LED WATERPROOF MODULE POLAR SERIES LED Type: 5050 SMD Consumption: 0.50 W / module Luminous Flux:
More informationLINEA 120 FIXED Colour White = MW Matte White RAL 9016 Colour Black = BL Matte Black RAL 9005 Beam Angle 60 EN60598 / EN62031 / EN62471.
LINEA 120 FIXED ECO solution Ø 180 mm Specifications LINEA 120 FIXED Colour White = MW Matte White RAL 9016 Colour Black = BL Matte Black RAL 9005 Beam Angle 60 Fixture Material Diecast Aluminium Environment/Applications
More information13 SERIES. Electronic step relays 10-16 A 13.81 13.91
13 Electronic step relays 10-16 A 13 13.81 - Electronic step relay - Rail mount - 1 Pole 13.91 - Electronic step relay and timing step relay Switch box mount - 1 Pole Fixed time (10 minutes) timing function
More informationAcclaim III Recessed Emergency Fluorescent Luminaires ATEX INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
Acclaim III Recessed Emergency Fluorescent Luminaires ATEX INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Important: Please read these instructions carefully before installing or maintaining this
More informationArecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual
0 P a g e H.264 Color or Day/Night SurroundVideo Installation Manual Inside the box: A. Arecont Vision SurroundVideo camera B. Mounting template C. RJ45 female to female coupler D. Hex key E. Security
More informationIS3016A Passive Infrared Motion Sensor with Anti-Mask - Installation Instructions
IS3016A Passive Infrared Motion Sensor with Anti-Mask - Installation Instructions QUICK LINKS Mounting Location Guidelines Open the Sensor Mount the Sensor Sensor Components and Settings Wire the Sensor
More informationNEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures
NEW RANGE OF CABINETS DRIVIATM Innovation at your service THE GLOBAL SPECIALIST in electrical and digital building infrastructures Drivia true innovation The new electrical panel for the residential and
More informationDaker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
More informationAccessories SUNNY REMOTE CONTROL
Accessories SUNNY REMOTE CONTROL Mounting Instructions SRC20-MO-IEN121010 IMEN-SRC20 Version 1.0 EN SMA Solar Technology AG 1 Information on this Document 1 Information on this Document Validity This
More information3500/93 System Display
3500/93 System Display Bently Nevada* Asset Condition Monitoring Description The 3500/93 System Display is designed to meet the requirements of American Petroleum Institute (API) Standard 670 and provide
More informationRGB Light Panel Applications. RGB LED Light Panel FEATURES & BENEFITS SPECIFICATION SHEET
RGB LED Light Panel E346146 E325925 FEATURES & BENEFITS AVAILABLE IN CUSTOM SIZES & SHAPES CAN BE USED IN FRAMELESS DESIGNS 3D V-CUTTING TECHNOLOGY MULTI-COLOR OPTION HIGH BRIGHTNESS (2,000-10,000 LUX)
More information2M IR Mini Dome Quick Installation Guide
2M IR Mini Dome 2M IR Mini Dome Quick Installation Guide Please follow the installation steps below to set up 2M IR Mini Dome IP Camera. Check the package contents against the list below. See P.1 Physical
More informationSPL 2-00/-01 OPERATION INSTRUCTIONS
SPL 2-00/-01 OPERATION INSTRUCTIONS Powerline Ethernet Adapter 500 Mbps EN Read and keep Operation Instructions SPL 2-00/-01 Safety Notes Do NOT use this product near water, for example, in a wet basement
More informationKNX Lighting Control System
KNX Lighting Control System Part 1 - Specification Lighting control system A. The following specification details the minimum standards for performance of components, material and operation of lighting
More informationponto trasso DESCRIPTION CHARACTERISTICS - FLOODLIGHTS ADVANTAGES VERSIONS
ponto trasso ponto trasso CHARACTERISTICS - FLOODLIGHTS Ponto Trasso Seal tightness: IP 67 (*) Impact resistance (glass): IK 10 (**) Static load resistance: 500 kg (*) Nominal voltage: 230 V AC Electrical
More informationPXM20-E. Operator unit DESIGO PX
9 234 DESIGO PX Operator unit PXM20-E Network-compatible operator unit for viewing and operating one or more DESIGO PX automation stations. High-grade display with adjustable contrast Simple key operation
More informationINDICATOR LAMPS & LED REPLACEMENT LAMPS
INDICATOR LAMPS & LED REPLACEMENT LAMPS Neon indicators (internal resistor) 120VAC 55-452-0 Red lens 120VAC 55-453-0 Amber lens 120VAC 55-455-0 Green lens 120VAC Neon indicators (internal resistor) 120VAC
More information1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions
Compact presence detector Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause
More informationMANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options.
MANUAL CONGRATULATIONS on the purchase of your new professional switch mode battery charger and tester. This charger and tester is included in a series of professional chargers from CTEK Sweden AB and
More informationCross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
More informationClimasys Thermal Management System. Schneider Electric Universal Enclosures 2009
Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal
More informationIntruder alarm. Pro 21 TM /Solfà TM. Installation and operating instructions N0064EG2/00
Intruder alarm Pro TM /Solfà TM Installation and operating instructions N00EG/00 Contents General presentation..., Presentation of a system with zones..., Product guide... Typical installation Preparation...
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More information