1 /ADSS8 Single-Stage Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Data...7 Wiring Diagrams...10 Accessories...11 Minimum Filter Sizes...11 Standard Features Single-stage gas valve Durable Silicon Carbide ignitor Quiet, single-speed draft inducer Self-diagnostic control board Color-coded low-voltage terminals Multi-speed blower motor Certain models comply with California Low NOx emissions standards Cabinet Features Installation: : Upflow, horizontal left or right ADSS8: Dedicated downflow Convenient left or right connection for gas and electrical service Cabinet air leakage (Q Leak ) 2% Heavy-gauge steel cabinet with durable baked-enamel finish Foil-faced insulated heat exchanger * Complete warranty details available from your local dealer or at To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home) and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. SS- 10/15 Amana is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas. Supersedes 3/15
2 Nomenclature A M S A X A A ,6 7,8, Brand Minor Revision A - Amana Brand A - Initial Release B - 1st Revision Configuration M - Upflow/Horizontal Major Revision C - Downflow/Horizontal A - Initial Release B - 1st Revision Gas Valve H - Convertible Two- Stage, Single Phase NOx S - Single Stage, Single Speed N - Natural Gas X - Low NOx AFUE 80-80% AFUE Cabinet Width A - 14" C - 21" MBTU/h B - 17½" D - 24½" ,000 BTU/h ,000 BTU/h ,000 BTU/h ,000 BTU/h Maximum CFM ,000 BTU/h ,000 BTU/h CFM CFM CFM A D S S B X A A ,6 7,8, Brand Minor Revision A - Amana Brand A - Initial Release B - 1st Revision Configuration M - Upflow/Horizontal Major Revision C - Downflow/Horizontal A - Initial Release B - 1st Revision Motor V - Variable Speed ECM / ComfortNet NOx E - Multi- Speed ECM S - Single Speed N - Natural Gas X - Low NOx Gas Valve M - Modulating S - Single Stage Cabinet Width C - Two Stage H - Convertible Single Phase A - 14" C - 21" B - 17½" D - 24½" AFUE 80-80% AFUE Maximum CFM CFM MBTU/h CFM ,000 BTU/h ,000 BTU/h CFM ,000 BTU/h ,000 BTU/h CFM ,000 BTU/h ,000 BTU/h 2 SS-
3 Product Specifications 0403A*A 0603A*A 0604B*A 0804B*A 0805C*A 1005C*A 1205D*A 1405DNB Heating Capacity Input ¹ 40,000 60,000 60,000 80,000 80, , , ,000 Natural Gas Output ¹ 32,000 48,000 48,000 64,000 64,000 80,000 96, ,000 LP Gas Output ¹ 32,000 48,000 48,000 64,000 64,000 80,000 96, ,000 AFUE Available 0.5 ESP Temperature Rise Range ( F) Circulator Blower Size (D x W) 10 x 6 10 x 6 10 x 8 10 x 8 10 x x x x 10 RPM ⅓ ⅓ ½ ½ ½ ½ ¾ ¾ Speed Vent Diameter 3 4" 4" 4" 4" 4" 4" 4" 4" No. of Burners Electrical Data Min. Circuit Ampacity Max. Overcurrent Device (amps) Ship Weight (lbs) ¹ Natural Gas BTU/h; for altitudes above from 0 to 5,500 above sea level, reduce input rating 4% for each 1,000 above 5,500 altitude. 2 DOE AFUE based upon Isolated Combustion System (ICS) 3 Vent and combustion air diameters may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada). 4 Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. 5 Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. Notes All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. Gas Service Connection ½ FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. SS- 3
4 ADSS8 Specifications 0403A*A 0603A*A 0804B*B 1005C*C Heating Capacity Input ¹ 40,000 60,000 80, ,000 Natural Gas Output 32,000 48,000 64,000 80,000 LP Gas Output 32,000 48,000 64,000 80,000 AFUE Available 0.5 ESP Temperature Rise Range ( F) Circulator Blower Size (D x W) 10 x 6 10 x 6 10 x 8 10 x 10 RPM 1/3 1/3 1/2 3/4 Speed Vent Diameter No. of Burners Electrical Data Min. Circuit Ampacity Max. Overcurrent Device (amps) Ship Weight (lbs) ¹ Natural Gas BTU/h; for altitudes above from 0 to 5,500 above sea level, reduce input rating 4% for each 1,000 above 5,500 altitude. 2 DOE AFUE based upon Isolated Combustion System (ICS) 3 Vent and combustion air diameters may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada). 4 Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. 5 Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. Notes All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. Gas Service Connection ½ FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. 4 SS-
5 Dimensions Alternate Gas Inlet 1¹³/₁₆ 1¾ Supply A B Alt. Flue Outlet Horizontal Left ⅝ 19½ 30½ 27⅞ 28½ 33⅜ Gas Alt. Inlet Gas Inlet High-Voltage Inlet 20 23⁵ ₁₆ High Alt. Voltage High Voltage Low-Voltage Inlet 13¼ Low Alt. Voltage Low Voltage 15 23¾ 28 B Return 23 Model A B Model A B 0403A*A 14 12½ 0805C*A 21 19½ 0603A*A 14 12½ 1005C*A 21 19½ 0604B*A 17½ D*A 24½ B*A 17½ DNB 24½ 23 Notes Line voltage wiring can enter through the right or left side of furnace. Low-voltage wiring can enter through the right or left side of furnace. Conversion kits for high-altitude (5500+ft) natural gas operation are available. Installer must supply the following gas line fittings, according to which entrance is used: Left: One 90º street elbow; one 2½ pipe nipple; one 90º elbow; straight pipe; one ground joint union Right: Straight pipe to reach gas valve Minimum Clearances to Combustible Materials Sides Rear Front¹ SW Vent² ¹ 24 clearance for serviceability recommended. ² Single Wall Vent (SW) to be used only as a connector. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada). Note: approved for line contact in the horizontal position. B Top SS- 5
6 ADSS8 Dimensions 19⅝ 19⅝ 28 A B High-Voltage Electrical Low-Voltage Electrical Gas Inlet Gas Inlet 33⅜ 18⅜ 11⅜ Model A B 0403A*A 14 12½ 0603A*A 14 12½ 0804B*B 17½ C*C 21 19½ Notes Line voltage wiring can enter through the right or left side of furnace. Low-voltage wiring can enter through the right or left side of furnace. Minimum Clearances to Combustible Materials Sides Rear Front¹ SW Vent² ¹ 24 clearance for serviceability recommended. ² Single Wall Vent (SW) to be used only as a connector. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada). B Top 6 SS-
7 Airflow Data CFM & Temperature Rise vs. External Static Pressure Model 0403A*A 0603A*A 0604B*A 0804B*A 0805C*A 1005C*A 1205D*A 1405DNB Motor Speed Tons AC¹ External Static Pressure, (Inches Water Column) CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM High 3 1, , , , , ,243 1,164 1,075 Med 2.5 1, , , , , , Med-Lo Low High 3 1, , , , , ,092 1, Med 2.5 1, , , , , Med-Lo Low High 4 2, , , , , ,786 1,700 1,601 Med 3.5 1, , , , , ,549 1,492 1,391 Med-Lo 3 1, , , , , ,378 1,328 1,261 Low 2.5 1, , , , , ,144 1,111 1,071 High 4 2, , , , , ,627 1,530 1,439 Med 3.5 1, , , , , ,475 1,394 1,307 Med-Lo 3 1, , , , , ,339 1,274 1,204 Low 2.5 1, , , , , ,125 1,125 1,080 High 5 2, , , , , ,837 1,712 1,584 Med 4 1, , , , , ,567 1,469 1,382 Med-Lo 3.5 1, , , , , ,405 1,346 1,235 Low 3 1, , , , , ,174 1, High 5 2, , , , , ,801 1,688 1,577 Med 4 1, , , , , ,577 1,493 1,399 Med-Lo 3.5 1, , , , , ,397 1,326 1,217 Low 3 1, , , , , ,168 1,118 1,060 High 5 2, , , , , ,027 1,902 1,786 Med 4 1, , , , , ,419 1,354 1,271 Med-Lo 3.5 1, , , , , ,245 1,183 1,106 Low 3 1, , , , , , High 5 2, , , , , ,027 1,902 1,786 Med 4 1, , , , , ,419 1,354 1,271 Med-Lo 3.5 1, , , , , ,245 1,183 1,106 Low 3 1, , , , , , ¹ at 0.5 ESP Notes: CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed. All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling and heating speed as needed. For most jobs, about 400 CFM per ton when cooling is desirable. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. This chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on the rating plate. The dashed (----) areas indicate a temperature rise not recommended for this model. At higher altitudes, a properly derated unit will have approximately the same temperature rise at a particular CFM, while ESP at the CFM will be lower. SS- 7
8 ADSS8 Airflow Data CFM & Temperature Rise vs. External Static Pressure Model 0403A*A 0603A*A 0804B*B 1005C*C Motor Speed Tons AC¹ External Static Pressure, (Inches Water Column) CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM High 3.0 1, , , , , ,116 1,116 1,099 Med 2.5 1, , , , , ,006 1, Med-Lo Low High 3.0 1, , , , , ,166 1,108 1,029 Med 2.5 1, , , , , Med-Lo Low High 4.0 2, , , , , ,726 1,628 1,529 Med 3.5 1, , , , , ,550 1,470 1,364 Med-Lo 3.0 1, , , , , ,402 1,328 1,239 Low 2.5 1, , , , , , High 5.0 2, , , , , ,937 1,808 1,689 Med 4.0 1, , , , , ,568 1,510 1,401 Med-Lo , , , , ,445 1,368 1,287 Low 3.0 1, , , , , ¹ at 0.5 ESP Notes: CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed. All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling and heating speed as needed. For most jobs, about 400 CFM per ton when cooling is desirable. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. This chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on the rating plate. The dashed (----) areas indicate a temperature rise not recommended for this model. At higher altitudes, a properly derated unit will have approximately the same temperature rise at a particular CFM, while ESP at the CFM will be lower. 8 SS-
9 Temperature Rise Range Chart BTU BTU/h OUTPUT Output vs TEMPERATURE Vs. Temperature RISE Rise Chart CHART 600 CFM CFM Formulas FORMULAS BTU BTU/h OUTPUT Output = CFM CFRM x 1.08 x x Rise RISE BTU OUTPUT RISE = BTU/H Output CFM Rise = 1.08 CFM CFM x OUTPUT Output BTU/h BTU/HR x 1,000 x 1000 TEMPERATURE Temperature Rise RISE SS- 9
10 Wiring Diagram 24 VAC HUMIDIFIER G R WARNING:DISCONNECT POWER BEFORE SERVICING.WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. CW Y HUMIDIFIER XFMR (6) GND GND (8) MVC (9) INTEGRATED CONTROL MODULE C2 GAS VALVE PU BL C RD RD BL FUSE PU 24V 115V XFMR STEADY ON OFF PU 1 2 GR OR INTEGRATED CONTROL MODULE 115 VAC HOT AND PARK TERMINALS DIAGNOSTIC LED LINE-H XFMR-H HEAT-H COOL-H GR HOT SURFACE IGNITER PU M1 GAS VALVE 115 VAC NEUTRAL PRIMARY LIMIT C2 BR RD ROLLOUT LIMITS (SINGLE CONTROL ON SOME MODELS) = NORMAL OPERATION = CONTROL FAILURE FLAME SENSOR RAPID FLASHES = REVERSED 115 VAC POLARITY/VERIFY GND AUXILIARY LIMITS BR BL (MED) OR (MED LOW) RD (LOW) (N) CICULATOR BLOWER CAP 15 PIN PLUG ON SOME MODELS INDUCED DRAFT BLOWER (HI) BR BR BLOWER COMPARTMENT BURNER COMPARTMENT NO PRESSURE SWITCH 1 FLASH = SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED) 2 FLASHES = PRESSURE SWITCH STUCK CLOSED 3 FLASHES = PRESSURE SWITCH STUCK OPEN 4 FLASHES = OPEN HIGH LIMIT 5 FLASHES = FLAME SENSE WITHOUT GAS VALVE 6 FLASHES = OPEN ROLLOUT 7 FLASHES = LOW FLAME SIGNAL COLOR CODES: YELLOW OR ORANGE PU PURPLE GR GREEN BLACK DOOR SWITCH SWITCH LOCATED IN BLOWER COMPARTMENT ON SOME MODELS BL RD PK PINK BR BROWN ITE BL BLUE GY GRAY RD RED RD PU BR RD RD OR OR OR OR BR 24 VAC HUMIDIFIER C 24V THERMOSTAT CONNECTIONS INTEGRATED CONTROL MODULE C G Y W R TO MICRO XFMR (3) XFMR-H LINE-H FP (2) DOOR SWITCH INTERNAL TO INTEGRATED CONTROL IGN IND MV (12) PS (10) PSO (4) HLI (7) HLO (1) RO2 (11) RO1 (5) AUXILIARY LIMIT CONTROLS C M1 ID BLOWER PRESSURE SWITCH NO MANUAL RESET ROLLOUT LIMIT CONTROL(S) (SINGLE CONTROL ON SOME MODELS) 24 VAC 40 VA TRANSFORMER COOL-H COOL HEAT HEAT-H 115 VAC FLAME SENSOR HOT SURFACE IGNITER ID BLWR CIRCULATOR BLWR JUNCTION BOX NOTES: 1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. 2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED EN SERVICING. 3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 C. USE COPPER CONDUCTORS ONLY. 4. BLOWER SPEEDS MUST BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION REQUIREMENTS SO AS TO PROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE CORRECT COOLING CFM. (SEE SPEC SHEET FOR AIR FLOW CHART) 5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES. CIR-N XFMR-N LINE-N AUTO RESET PRIMARY LIMIT CONTROL WARNING: DISCONNECT POWER DISCONNECT BEFORE SERVICING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. L GND N TO 115VAC/ 1Ø /60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE JUNCTION BOX TO 115 VAC/ 1/60HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE LOW VOLTAGE (24V) LOW VOLTAGE FIELD HI VOLTAGE (115V) HI VOLTAGE FIELD JUNCTION TERMINAL PLUG CONNECTION LINE-N GND LINE H IGN-N IND-N EQUIPMENT GND FIELD GND FIELD SPLICE SWITCH (TEMP.) IGNITER SWITCH (PRESS.) OVERCURRENT PROT. DEVICE INTEGRATED CONTROL MODULE High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. 0140F00119-C 10 SS-
11 Accessories Model Description LPT-03 ¹ HANG21 AFE18-60A MVK-01 ² MVK-02 ² FTK04 LP Conversion Kit High-Altitude Natural Gas Kit (5500+ ft) Fossil Fuel Kit Masonry Vent Kit Masonry Vent Kit (for 1205D and 1405D models only) Twining Kit ¹ White-Rodgers and Honeywell valves ² Upflow applications only Downflow Sub-base for: Model Description 0403AX** 0603AX** SBT14 14 Furnace 0804BX** SBT17 17½ Furnace 1005CX** SBT21 21 Furnace Minimum Filter Sizes Model #s Filter Size (in²) 0403A* 0603A* (1) 16 x 25 (Side) or (1) 14 x 24 (Bottom) 0604B* 0804B* (1) 16 x 25 (Side or Bottom) 0805C* (1) 16 x 25 (Side or Bottom) ¹ 1005C* (2) 16 x 25 (Side) or (1) 20 x 25 (Bottom) Note: Other size filters of equal or greater surface area may be used; filters may also be centrally located. ¹ Use 2-16 X 25 filters on side returns or 20 X 25 filter on bottom return if furnace is connected to a cooling unit over 4 tons nominal capacity. 1205D* 1405D* (2) 16 x 25 (Side) or (1) 24 x 24 (Bottom) ADSS8 Minimum Filter Sizes Model #s 403A* 603A* 804B* ADSS81005C* Filter Size (in²) (2) 10 x 20 or (1) 14 x 25 (Top Return) (2) 14 x 20 or (1) 16 x 25 (Top Return) Note: Other size filters of equal or greater surface area may be used; filters may also be centrally located. (2) 14 x 20 or (1) 20 x 25 (Top Return) SS- 11
12 Notes Amana is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P. All rights reserved. Our continuing commitment to quality products may mean a change in specifications without notice Goodman Company, L.P. Houston, Texas Printed in the USA SS-
TECHNICAL MANUAL GDS8 & GHS8
TECHNICAL MANUAL AL GDS8 & GHS8 33-3/8" 80% Gas Furnace Units Refer to Service Manual RS6610004 for installation, operation, and troubleshooting information. All safety information must be followed as
More informationCooling Capacity CFM range @.5 in. w.c. (125 Pa)
N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air
More informationCooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in cooling California NOx
More informationF9MXE. Product Specifications
96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Select models earn the ENERGY STAR (See below, indicated with check mark.) Xtra SEER ECM blower motor Supports
More informationCooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in
More informationM7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace
TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially
More informationG9MXE. Product Specifications
Up to 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL Up to 96% AFUE, all models all positions California NOx approved Select models earn the ENERGY STAR (See below, indicated with check mark.)
More informationAVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV Comfortnet Compatible 1½ to 5 Tons. Contents.
Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV Comfortnet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... 3 Dimensions...
More informationXV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE
UPF/HORIZONTAL 2-, VARIABLE SPEED GAS-FIRED FURNACE XV80 MODELS TUD2B060A9V3VB, TUD2B080A9V3VB TUD2C080A9V4VB, TUD2C080B9V4VB TUD2B00A9V3VB, TUD2C00A9V5VB TUD2C00B9V5VB, TUD2DA9V5VB TUD2DB9V5VB, TUD2DA9V5VB
More informationCommercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
More informationTECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES
TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S NATURAL GAS 40-130 MBH INPUT Due to continuous product improvement, specifications are subject to change
More informationXV 95. Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace PUB. NO.
Upflow/ Horizontal Left, Downflow/ Horizontal Right Speed Two Stage Condensing Gas-Fired Furnace XV 95 TUH2B060A9V3VB TUH2B080A9V3VB TUH2B080A9V4VB TUH2C100A9V4VB TUH2C100A9V5VB TUH2D120A9V5VB Direct Vent
More informationE2 Series Electric Furnaces
E2 Series Electric Furnaces Service Manual Table of Contents Electrical Requirements... 10 Codes, Specifications Requirements... 10 Connection Supply Service Wires... 10 Furnace Sequence of Operation...
More informationTECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373. 2 Inch PowerVent LED Indicator Explanations & Troubleshooting Table
New Robertshaw control valve was introduced in May 2008 as a replacement part. See last page for troubleshooting this replacement part. All voltage inputs are 120V. All electrical connectors are Molex
More informationInstallation Instructions
H5HK Series Installation Instructions 3 Phase Electric Heater Kits 7.5 and 0 TON Package A/C Systems Description Installation of 08/40V and 480V H5HK 3 Phase Heater Kits in 7.5 and 0 TON Packaged Air Conditioners.
More informationGas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard
LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled
More informationYour safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
More informationhttp://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html TECHNICAL SERVICE DEPARTMENT Effective October 2007, we transitioned to the White Rodgers (Intelli-Vent TM )Thermostat Control for
More informationOIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.
FORM NO. O11-608 REV. 2 Supersedes Form No. O11-608 Rev. 1 OIL FURNACES CLASSIC PREMIUM CLASS UPF OIL FURNACES ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.30 kw] The Rheem Classic
More informationhttp://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html APPLY POWER TO APPLIANCE FIELD WIRING CORRECT? DPLAY ERROR CODE 1 OR 2 Intelli-Vent TM Sequence of Operation REQUEST FOR HEAT PRESENT?
More informationDigi-Motor Installation Guide
Digi-Motor Installation Guide Installation Video...located at marsdelivers.com Digi-Motor Installation Guide Digi-Motor For technical assistance with your Azure Digi-Motor, call the MARS technical support
More informationG234X-55 Conventional Gas Boiler
Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus G234X-55 fl oor standing hot water boiler(s), suitable with natural
More informationG26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS
Service Literature G26 SERIES UNITS G26 series units are high-efficiency upflow gas furnaces manufactured with DuralokPlust aluminized steel clamshell-type heat exchangers. G26 units are available in heating
More informationRoof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
More informationARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features
Series Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Heater Kit Nomenclature... 3 Dimensions... 4 Airflow Data... 5 Heat Kit
More informationCooling/Heat Pump Convertible Air Handlers
Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way
More informationOIL FURNACES. Clean, Comfortable Oil Heat From
OIL FURNACES Clean, Comfortable Oil Heat From Features 3 1 2 5 10 9 7 6 8 4 1 Foil-faced high density fi berglass insulation gives durable, insulating heat and sound protection. 2 Heavy-duty 14 gauge steel
More informationIMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.
QUIET-ONE Environmental Products 2000 Kickspace Heater Series Models: KS 2004, KS 2006 KS 2008, KS 2010 INSTALLATION OPERATING MAINTENANCE Please read these instructions thoroughly before beginning your
More information80UHG. Service Literature
Service Literature Corp. 9728 L12 Revised 01 2002 80UHG 80UHG series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with tubular heat exchangers formed
More informationAIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency
FORM NO. H11-52 REV. 3 Supersedes Form H11-52 Rev. 2 AIR HANDLERS AIR HANDLERS RHLA- Efficiency featuring R-22 Refrigerant RHLL- Efficiency featuring Earth-Friendly R-10A Refrigerant earth friendly refrigerant
More informationPART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual
PART 8: FIELD WIRING A. INSTALLATION MUST COMPLY WITH: 1. National Electrical Code and any other national, state, provincial or local codes or regulations. 2. In Canada, CSA C22.1 Canadian Electrical Code
More informationHigh efficiency, cast-iron gas boiler
SENTRY High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY SENTRY High efficiency, cast-iron gas boiler A smarter choice for informed The boiler you choose for your home
More informationPRODUCT DESIGN. 5. Furnace awaits call from thermostat.
Goodman / Amana Distinctions Brand Single-Stage 80% or 90% Furnaces White-Rodgers 50A55 Integrated Ignition Control 1. 115 VAC power applied to furnace. 2. Integrated ignition control module performs internal
More informationSplit System Cooling Product Data
Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-01 Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess
More informationRESIDENTIAL PRODUCT LINE CARD 15.5
RESIDENTIAL PRODUCT LINE CARD 15.5 Amana is a registered trademark of Maytag Corporation or its related companies and is used under license to Goodman Company, L.P., Houston, TX, USA. All rights reserved.
More informationNAVIEN AMERICA INC. 17855 FITCH AVENUE
Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:
More informationFossil fuel heating equipment
Fossil fuel heating equipment principles and troubleshooting techniques Application Note This application note was written to provide you with an understanding of the basic principles of fossil fuel heating
More informationMCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
More informationInstallation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008
Installation Manual Rental Services Air Handling Units July 2008 CHS-SVN01A-EN Copyright 2008 Trane All rights reserved This document and the information in it are the property of Trane and may not be
More informationARMSTRONG AIR HEAT PUMPS www.armstrongair.com
INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM EFC/EFV... 5-10 electric Heat Kits... 5-11 evaporator coils EC1P / EM1P UPFLOW / COUNTERFLOW APPLICATIONS and upflow / horizontal applications (CASED)... 5-6 5-7
More informationLPM-06 CONVERSION KIT
LPM-06 CONVERSION KIT TWO-STAGE FURNACE NATURAL GAS TO L.P. GAS CONVERSION Goodman Manufacturing Company, L.P. 2009-2011 5151 San Felipe, Suite 500, Houston, TX 77056 www.goodmanmfg.com -or- www.amana-hac.com
More information36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve
Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION
More informationCommercial Gas Water Heater
Commercial Gas Water Heater 3-Year Limited Tank/1-Year Limited Parts Warranty* The Polaris has a high grade 444 stainless steel tank with brass connections for years of dependable, trouble-free service
More informationCircuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)
UNIT OBJECTIVES Describe the concept of year-round air conditioning List three typical year-round air conditioning system types List the five ways to condition the air Determine airflow for a cooling system
More informationResidential/Commercial Gas Condensing High Efficiency Tankless Water Heaters
Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger
More informationCommercial Gas Water Heaters
POWERED BURNER MODELS LARGE-VOLUME POWERED BURNER FEATURES The large-volume powered burner line includes the largest, most powerful A. O. Smith tanktype gas water heaters. With tank capacities up to 600
More informationReplacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
More informationYour safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT ALPKT7- INSTALLATION INSTRUCTIONS PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements... INSTALLATION INSTRUCTIONS...
More informationSL280UHV SERIES GAS FURNACE WARNING
2010 Lennox Industries Inc. Dallas, Texas, USA 506677 01 11/2010 Supersedes 506409 01 SL280UHV SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could
More informationCommunicating Controls Service Manual
Communicating Controls Service Manual History 1977 1991 Theory of Operation Common Components Telephone Access Module Service/Troubleshooting Table of Contents Warnings and Cautions... 2 Theory of Operation
More informationSplit System Cooling Product Data
Split System Cooling Product Data XR17 4TTR7 2, 3, 4 & 5 Tons PUB. NO. 22-1884-01 Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER All Aluminum SPINE FIN coil DURATUFF
More informationIndirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................
More informationPropane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL
Propane Conversion Kit Supersedes: 145.25-IOM2 (708) Form 145.25-IOM2 (908) PROPANE CONVERSION KIT INSTALLATION MANUAL "LPKIT " - PROPANE CONVERSION KIT Kits are available for field conversion from natural
More informationSplit System Heat Pump Product Data
Split System Heat Pump Product Silver 14 4A6H4 1 1 /2-5 Tons PUB. NO. 12-1175-07 Contents Features and Benefits 2 Model Nomenclature 3 General 4 Product Specifications 4 A-weighted Sound Power Level [db(a)]
More informationBuck - Boost Transformers
Buck - Boost Transformers Contents Buck - Boost Transformers - Terms & Definitions... 48 Buck - Boost Transformers - Sizing... 50 Quick Reference Chart - 08, 0, 40 Volts Single & Three Phase... 5 Single
More informationBUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
More informationAir Conditioner 457915 B57915 459516 B59516 540315 540316 640312 640315
RECORD THIS INFORMATION FOR FUTURE REFERENCE: Number Serial Number ADB Number ADB Serial Number Date Purchased USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516 CANADA Dometic
More information12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST
12VDC MAGNETIC ED DIMMABE POER SUPPIES SPEC SEET DIGEST TM-30-DIM TM-50-DIM T-60-DIM TM100-DIM TM200-DIM TM300-DIM iring Diagram for TM-50-DIM and TM-100-DIM ED 12VDC MAGNETIC DIMMABE 30 POER SUPPY Smallest
More informationAPPENDIX 7.2. DECODING OF MANUFACTURER MODEL NUMBERS LIST OF TABLES
APPENDIX 7.2. DECODING OF MANUFACTURER MODEL NUMBERS LIST OF TABLES Table 7.2.1 Amana Number Description... 7.2-1 Table 7.2.2 Carrier Number Description... 7.2-1 Table 7.2.3 ICP Number Description... 7.2-2
More informationWARNING CAUTION 21V51U-843 DESCRIPTION PRECAUTIONS
The kit Includes: CAUTI 21V51U-843 Integrated Two-Stage/Variable Speed Motor Hot Surface Ignition Control Kit INSTALLATI INSTRUCTIS Operator: Save these instructions for future use! FAILURE TO READ AND
More informationTANKLESS WATER HEATER INSTALLATION DIAGRAMS
TANKLESS WATER HEATER INSTALLATION DIAGRAMS Installation Diagrams Tankless Installation / Optional Return Small 10-15 Gallon Point-of-Use Water Single and Optional Return : One single, small capacity water
More informationSIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND
Honeywell Electronic Ignition Troubleshooting Tech Tip April 2007 The Honeywell S8610H Intermittent Pilot Module provides the ignition sequencing, pilot spark, pilot flame monitoring, Pilot Valve (PV)
More informationElectrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug
Electrical Connection When installed the range must be electrically grounded in accordance with local codes or; in the absence of local codes with the National Electrical Code ANSI/NFPA 70, latest edition.
More informationG670 Intermittent Pilot Ignition Controls
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin Issue Date 0300 Intermittent Pilot Ignition Controls Figure 1: Intermittent Pilot Ignition Control
More information543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
More informationG6 Series. 90+ High Efficiency Upflow/Downflow Models. Service Manual
G6 Series 90+ High Efficiency Upflow/Downflow Models Service Manual D. C. B. A. Typical meters used to service furnaces. A. Differential Pressure Gauge B. Volt-Ohm Meter C. Manometer D. Slant Gauge TABLE
More informationHVAC INDOOR MAKE-UP AIR HANDLERS
GIAC-7 HVAC INDOOR MAKE-UP AIR HANDLERS Application Manual PACKAGED INDOOR ARRANGEMENTS FOR MAKE-UP AIR, HEATING AND COOLING Contents 2 PAGE GENERAL INFORMATION 2, 3 MODEL NUMBER DESCRIPTION 4 INDOOR DUCT
More informationWON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin 30-34 / March 2013
Bulletin 30-34 / March 2013 INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES General The information on the following pages is to provide the installer the necessary information to properly install the
More informationCommercial Semi-Instantaneous Water Heaters
FEATURES HWI Models A. O. Smith s HWI models are available for operation with steam or boiler water as the energy source. They are factory assembled with components sized, piped and checked at the factory
More informationUSER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........
More informationSplit System Cooling Product Data
Split System Cooling Product Data 4TTB3018-060 1½ 5 Tons PUB. NO. 22-1843-14 Features and Benefits Efficiency up to 13.25 SEER All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, easy
More informationWMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler
WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler Installation Operation Maintenance The WMSLW/WMBLW series is designed for installation in a closet, utility
More informationINDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-211 REV. 7 Supersedes Form No. C11-211 Rev. 6 INDOOR COILS RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM
More information37E73A-903 & 906 INTELLI-VENT
37E73A-903 & 906 INTELLI-VENT Water Heater Thermostat Control Installation Instructions For Natural Gas Only Operator: Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
More informationFeatures and Benefits. Product Overview. Installation Overview. Sales Strategy Overview FPO
RESCUE EcoTech Direct Drive Blower Motor The High Efficiency ECM/BPM Drop-in Replacement Blower Motor Agenda Features and Benefits Product Overview Installation Overview Sales Strategy Overview FPO High
More informationIntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide
IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide *619751* P/N 619751 - Rev C IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS
More informationSERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications
More informationEFFECTIVE OCTOBER 2005. Atwood Furnaces. and Digital Thermostats
EFFECTIVE OCTOBER 2005 Atwood Furnaces and Digital Thermostats Unique 2-Stage System Set the temperature, turn the thermostat on automatic and let the furnace take over! During cold start-ups, the furnace
More informationOPERATIONAL CHECKS & SAFETY CIRCUIT DESCRIPTION
OPERATIONAL CHECKS & SAFETY CIRCUIT DESCRIPTION Integrated control module performs internal checks. Integrated control module displays 8 8 on dual 7-segment display LED s. Integrated control module monitors
More informationCased/Uncased Coils For Gas And Oil Furnaces
Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFL- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] Rheem Indoor Coils are designed for use
More informationADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
More informationGCS16 GCS20 WARNING CAUTION
Service Literature Corp. 0110 L6 Revised 12 2004 GCS16/GCS20 SERIES UNITS GCS16 GCS20 2 to 5 Ton GCS16/20 series units in the 2 to 5 ton (7.0 to 17.0 kw) cooling size are packaged combination gas heat
More informationOwner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.
INSTALLATION, OPERATING AND SERVICE MANUAL FOR EASY RADIANT WORKS HEATWAVE MODEL GH-25-40 GAS FIRED, VENTED INFRARED TUBE HEATER FOR RESIDENTIAL & COMMERCIAL / INDUSTRIAL APPLICATIONS. For Your Safety
More informationTB-A028-06 - A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION
1 2 3 4 5 Inadequate or no earth ground sensed by the Intelli-Vent control. Power supply to Intelli-Vent control has reversed polarity. Pressure switch circuit remaining closed for more than 5 seconds
More informationCommunicating Wall Control Installation Manual TSTAT0101SC
Communicating Wall Control Installation Manual TSTAT0101SC U.S. Patent No. 7,243,004 U.S. Patent No. 7,775,452 616 01 1017 02 08/07/12 Safety Considerations... 7 Introduction... 8 Quick Start... 9 Set
More informationHeating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
More informationprestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE 2008-36 TSG-PRESTIGE Date revised: 12/6/10
prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE Date revised: 12/6/10 2008-36 TSG-PRESTIGE Table of Contents INTRODUCTION Page 1-2 SERVICING TIPS AND INSTRUCTIONS Page 3-4
More information80% SINGLE STAGE GAS FURNACES
80% SINGLE STAGE GAS FURNACES *8DNL, *8MPL & *8MPN B * Denotes brand H, C, T This manual supports single stage B series and later non -condensing gas furnaces Manufactured by: Part Number 441 08 2011 00
More informationINSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
More informationDIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
More informationDraper Low Voltage, Remote Control, Serial and Network Wiring Guide
Draper Low Voltage, Remote Control, Serial and Network Wiring Guide Copyright 2007 Draper Inc. Form LV-RC-Serial-Network_Wiring07 Print ed in U.S.A. Draper Low Voltage, Remote Control, Serial and Network
More information2007 W-SERIES (CHEVROLET & GMC) N-SERIES (ISUZU) 250 NPR/W3500, NPR HD/W4500, NQR/W5500, NRR/W5500-HD Diesel Electrical Symbols
2007 W-SERIES (CHEVROLET & GMC) N-SERIES (ISUZU) 250 NPR/W3500, NPR HD/W4500, NQR/W5500, NRR/W5500-HD Diesel Electrical Symbols Symbol Meaning Symbol Meaning Symbol Meaning Fuse Electronic Parts Coil (Inductor),
More informationModel 7586. Description / Applications. Intermittent Pilot Gas Ignition Control
PARTS & ACCESSORIES Model 7586 Intermittent Pilot Gas Ignition Control Description / Applications The Beckett GeniSys Intermittent Pilot Gas Ignition Control is a 24 Vac gas ignition and safety control.
More informationCooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
More informationSeries GM. Peerless Boilers. Residential/Commercial Gas Boilers
Peerless Boilers Series GM Residential/Commercial Gas Boilers The Series GM cast iron, hot water boiler is ideal for use in large residences or commercial applications. This gas-fired, atmospheric boiler
More informationOil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
More informationModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60
ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac II air conditioner is a vertical, wall mounted, cost effective air conditioner
More informationINDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-213 REV. 4 Supersedes Form No. C11-213 Rev. 3 INDOOR COILS RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM
More informationINSTALLATION INSTRUCTIONS
2008 Lennox Industries Inc. Dallas, Texas, USA WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Installation and
More informationCommercial Gas Water Heaters
CYCLONE Mxi MODULATING MODULATING BURNER ADVANCES THE CYCLONE TO HIGHER LEVELS OF EFFICIENCY The full line of A. O. Smith Cyclone Mxi condensing water heaters has been designed to provide years of dependable