YGFC. Fan Coil Units. Size: 02 ~ 12 Air Flow: 378 ~ 2524m 3 /h. Ceiling Concealed Type. Vertical Concealed Type. Vertical Exposed Type

Size: px
Start display at page:

Download "YGFC. Fan Coil Units. Size: 02 ~ 12 Air Flow: 378 ~ 2524m 3 /h. Ceiling Concealed Type. Vertical Concealed Type. Vertical Exposed Type"

Transcription

1 YGFC Fan Coil Units Ceiling Concealed Vertical Concealed Vertical Exposed Ceiling Exposed Size: ~ Air Flow: 38 ~ 5m 3 /h

2 Content & Nomenclature CONTENT Design Physical Data Cooling Capacity Heating Capacity Dimensions 3 Wiring Diagram NOMENCLATURE YGFC CC 3 S S: standard H: high static pressure Coil Row : rows cooling coil York Fan Coil Unit Size 3 8 CC: ceiling concealed CD: ceiling concealed with down return plenum CB: ceiling concealed with back return plenum VC: vertical concealed CE: ceiling exposed VE: vertical exposed 3: 3 rows cooling coil : rows cooling coil A: 3 rows cooling coil & row heating coil ( for pipe system)

3 Design 8 models available; Sized from 38 to 5 m 3 /h; More options to customer: rows, 3 rows, rows, and 3+ rows coil. Design and manufacturing flexibilities, more special order for customer; Complete line accessories, and less leadtime; Reasonable price. Features and Benefits Well designed and precisely manufactured; New style and advanced structure; High efficiency, low noise and power consumption; Safe and reliable; Easy installation and maintenance. High Energy Efficiency High efficiency AL fin cooling coil, rows, 3 rows, rows and 3+ rows coil are available. Coil provides high rate of heat transfer with large air flow and low noise fan. Quiet Operation and Energy Conservation Units have been optimized to ensure quiet and high efficient operation. Aluminium fan blade can avoid the aging distortion problem of plastic made fan wheel, and rust problem of steel fan wheel. Water knockout is made of brastil with uniform water flow and less water pressure drop. Maintenance Cost Motor uses permanent split capacitor, high precision and quality self-lube ball bearings, low noise and long life. Central axis of motor has been thermal refined and surface anti-corrosion treated. High Flexibility and Installation Cost Ceiling concealed (horizontal concealed) coil's fan mounting plate can interchange with flange of the opening. Client can change the direction of duct connection in field, resulting in quick and simple installation. Vertical concealed fan coil unit can be mounted under window, client can renovate house freely, and it will be comfortable and elegant. Vertical exposed fan coil unit can be placed at any location of a room, beautiful shape matches with furniture, it will be comfortable and decorative. Ceiling exposed (horizontal exposed) fan coil unit can be mounted on ceiling directly. Vertical and ceiling exposed unit can be mounted by removing the enclosure, it is easy to maintain and install.

4 Physical Data Rows Standard Item 3 8 High Air Flow (m 3 /h) Cooling capacity heat (W) Nominal Capacity (W) (high ) heat (W) Heating capacity (W) Water flow (kg/h) Water pressure drop (kpa) Fan Aluminium centrifugal forward-curved blade Three permanent split capacitor motor Unit Net Weight (kg) Cooling Coil Motor Power Supply Power input (W) Sound level db(a) Piping Connection Row x stage Max. Allowable work pressure (MPa) Water inlet & outlet Drain CC CB/CD VE/CE VC ACV-ph-Hz High efficiency copper tube aluminium ripple fin coil x8.5 3/ tube female thread 3/ tube male thread Note:. Airflow is based on Pa external static pressure.. Cooling capacity is specified at: C DB, C WB; C inlet chilled water temperature, 5 C temperature rise. 3. Heating capacity is specified at: C DB; C inlet hot water temperature; same water flow and airflow as cooling.. Sound level db(a) is measured in acoustical chamber according to ARI3-98, cooling and heating capacity is measured according to ARI-9 standard.

5 Physical Data (Cont.') Rows High Static Pressure Item 3 8 High Air Flow (m 3 /h) Cooling capacity heat (W) Nominal Capacity (W) (high ) Heating capacity (W) Water flow (kg/h) heat (W) Water pressure drop (kpa) Fan Aluminium centrifugal forward-curved blade Three permanent split capacitor motor Unit Net Weight (kg) Cooling Coil Motor Power Supply Power input (W) Sound level db(a) Piping Connection Row x stage Max. Allowable work pressure (MPa) Water inlet & outlet Drain CC CB/CD VE/CE VC ACV-ph-Hz High efficiency copper tube aluminium ripple fin coil x8.5 3/ tube female thread 3/ tube male thread Note:. Airflow is based on Pa external static pressure.. Cooling capacity is specified at: C DB, C WB; C inlet chilled water temperature, 5 C temperature rise. 3. Heating capacity is specified at: C DB; C inlet hot water temperature; same water flow and airflow as cooling.. Sound level db(a) is measured in acoustical chamber according to ARI3-98, cooling and heating capacity is measured according to ARI-9 standard. 3

6 Physical Data (Cont.') 3 Rows Standard Item 3 8 High 3 5 Air Flow (m 3 /h) Cooling capacity heat (W) Nominal Capacity (W) (high ) Heating capacity (W) Water flow (kg/h) heat (W) Water pressure drop (kpa) Fan Aluminium centrifugal forward-curved blade Three permanent split capacitor motor Unit Net Weight (kg) Cooling Coil Motor Power Supply Power input (W) Sound level db(a) Piping Connection Row x stage Max. Allowable work pressure (MPa) Water inlet & outlet Drain CC CB/CD VE/CE VC ACV-ph-Hz High efficiency copper tube aluminium ripple fin coil 3x8.5 3/ tube female thread 3/ tube male thread Note:. Airflow is based on Pa external static pressure.. Cooling capacity is specified at: C DB, C WB; C inlet chilled water temperature, 5 C temperature rise. 3. Heating capacity is specified at: C DB; C inlet hot water temperature; same water flow and airflow as cooling.. Sound level db(a) is measured in acoustical chamber according to ARI3-98, cooling and heating capacity is measured according to ARI-9 standard.

7 Physical Data (Cont.') 3 Rows High Static Pressure Item 3 8 High Air Flow (m 3 /h) Cooling capacity heat (W) Nominal Capacity (W) (high ) Heating capacity (W) Water flow (kg/h) heat (W) Water pressure drop (kpa) Fan Aluminium centrifugal forward-curved blade Three permanent split capacitor motor Unit Net Weight (kg) Cooling Coil Motor Power Supply Power input (W) Sound level db(a) Piping Connection Row x stage Max. Allowable work pressure (MPa) Water inlet & outlet Drain CC CB/CD VE/CE VC ACV-ph-Hz High efficiency copper tube aluminium ripple fin coil 3x8.5 3/ tube female thread 3/ tube male thread Note:. Airflow is based on Pa external static pressure.. Cooling capacity is specified at: C DB, C WB; C inlet chilled water temperature, 5 C temperature rise. 3. Heating capacity is specified at: C DB; C inlet hot water temperature; same water flow and airflow as cooling.. Sound level db(a) is measured in acoustical chamber according to ARI3-98, cooling and heating capacity is measured according to ARI-9 standard. 5

8 Physical Data (Cont.') Rows Standard Item 3 8 High Air Flow (m 3 /h) Cooling capacity heat (W) Nominal Capacity (W) (high ) Heating capacity (W) Water flow (kg/h) heat (W) Water pressure drop (kpa) Fan Aluminium centrifugal forward-curved blade Three permanent split capacitor motor Unit Net Weight (kg) Cooling Coil Motor Power Supply Power input (W) Sound level db(a) Piping Connection Row x stage Max. Allowable work pressure (MPa) Water inlet & outlet Drain CC CB/CD VE/CE VC ACV-ph-Hz High efficiency copper tube aluminium ripple fin coil x8.5 3/ tube female thread 3/ tube male thread Note:. Airflow is based on Pa external static pressure.. Cooling capacity is specified at: C DB, C WB; C inlet chilled water temperature, 5 C temperature rise. 3. Heating capacity is specified at: C DB; C inlet hot water temperature; same water flow and airflow as cooling.. Sound level db(a) is measured in acoustical chamber according to ARI3-98, cooling and heating capacity is measured according to ARI-9 standard.

9 Physical Data (Cont.') Rows High Static Pressure Item 3 8 High Air Flow (m 3 /h) Cooling capacity heat (W) Nominal Capacity (W) (high ) Heating capacity (W) Water flow (kg/h) heat (W) Water pressure drop (kpa) Fan Aluminium centrifugal forward-curved blade Three permanent split capacitor motor Unit Net Weight (kg) Cooling Coil Motor Power Supply Power input (W) Sound level db(a) Piping Connection Row x stage Max. Allowable work pressure (MPa) Water inlet & outlet Drain CC CB/CD VE/CE VC ACV-ph-Hz High efficiency copper tube aluminium ripple fin coil x8.5 3/ tube female thread 3/ tube male thread Note:. Airflow is based on Pa external static pressure.. Cooling capacity is specified at: C DB, C WB; C inlet chilled water temperature, 5 C temperature rise. 3. Heating capacity is specified at: C DB; C inlet hot water temperature; same water flow and airflow as cooling.. Sound level db(a) is measured in acoustical chamber according to ARI3-98, cooling and heating capacity is measured according to ARI-9 standard.

10 Cooling Capacity - Rows Standard Note:. DB= dry bulb; WB= wet bulb; sensible = sensible heat; total = total heat.. Water flow is per Physical Data, air flow is at high. 3. Recommended selection range. (W) External Static Pressure (Pa) Air Flow (m 3 /h) Air Entering Temperature DB5 C WB8 C DB C WB9 C DB C WB C DB8 C WB C 3 8 Inlet Water Temp. ( C) Heat transfer correction factor at different fan

11 Cooling Capacity -3 Rows Standard Note:. DB= dry bulb; WB= wet bulb; sensible = sensible heat; total = total heat.. Water flow is per Physical Data, air flow is at high. 3. Recommended selection range. (W) External Static Pressure (Pa) Air Flow (m 3 /h) Air Entering Temperature DB5 C WB8 C DB C WB9 C DB C WB C DB8 C WB C 3 8 Inlet Water Temp. ( C) Heat transfer correction factor at different fan

12 Cooling Capacity - Rows Standard Note:. DB= dry bulb; WB= wet bulb; sensible = sensible heat; total = total heat.. Water flow is per Physical Data, air flow is at high. 3. Recommended selection range. (W) External Static Pressure (Pa) Air Flow (m 3 /h) Air Entering Temperature DB5 C WB8 C DB C WB9 C DB C WB C DB8 C WB C 3 8 Inlet Water Temp. ( C) Heat transfer correction factor at different fan

13 Cooling Capacity - Rows High Static Pressure Note:. DB= dry bulb; WB= wet bulb; sensible = sensible heat; total = total heat.. Water flow is per Physical Data, air flow is at high. 3. Recommended selection range. (W) External Static Pressure (Pa) Air Flow (m 3 /h) Air Entering Temperature DB5 C WB8 C DB C WB9 C DB C WB C DB8 C WB C 3 8 Inlet Water Temp. ( C) Heat transfer correction factor at different fan

14 Cooling Capacity -3 Rows High Static Pressure Note:. DB= dry bulb; WB= wet bulb; sensible = sensible heat; total = total heat.. Water flow is per Physical Data, air flow is at high. 3. Recommended selection range. (W) External Static Pressure (Pa) Air Flow (m 3 /h) Air Entering Temperature DB5 C WB8 C DB C WB9 C DB C WB C DB8 C WB C 3 8 Inlet Water Temp. ( C) Heat transfer correction factor at different fan

15 Cooling Capacity - Rows High Static Pressure Note:. DB= dry bulb; WB= wet bulb; sensible = sensible heat; total = total heat.. Water flow is per Physical Data, air flow is at high. 3. Recommended selection range. (W) External Static Pressure (Pa) Air Flow (m 3 /h) Air Entering Temperature DB5 C WB8 C DB C WB9 C DB C WB C DB8 C WB C 3 8 Inlet Water Temp. ( C) Heat transfer correction factor at different fan

16 Heating Capacity Note: Water flow and airflow are per Physical Data. (W) Rows Heating Capacity ( pipes system) Note: Water flow and airflow are per Physical Data. 3 Rows Heating Capacity ( pipes system) External static Pressure (Pa) Inlet Water Temp. ( C) S H S H S H S H S H S H S H Air Entering Temperature C (W) External static Pressure (Pa) Inlet Water Temp. ( C) S H S H S H S H S H S H S H Air Entering Temperature C

17 Heating Capacity (Cont.') Note: Water flow and airflow are per Physical Data. (W) Rows Heating Capacity ( pipes system) Note: Water flow and airflow are per Physical Data. (W) Row Heating Capacity ( pipes system) Heat Transfer Correction Factor of Different Fan Speed External static Pressure (Pa) Inlet Water Temp. ( C) S H S H S H S H S H S H S H Air Entering Temperature C External static Pressure (Pa) Inlet Water Temp. ( C) S H S H S H S H S H S H S H Air Entering Temperature C 5 S.9. H S H.85. S.8. H.8. S.88.5 H.88. 8S.8. 8H.8. S.8. H.88. S.88. H.89.

18 Dimensions Ceiling Concealed Water outlet G3/ Water Inlet G3/ Drain Connection R3/ YGFC--CC-(3,)-S(H) YGFC-3-CC-(3,)-S(H) YGFC--CC-(3,)-S(H) YGFC--CC-(3,)-S(H) YGFC-8-CC-(3,)-S(H) YGFC--CC-(3,)-S(H) YGFC--CC-(3,)-S(H) A B Note:. Right hand unit shown, left hand unit opposite.. The plenum connection (down plenum or back plenum) can be changed in according to field installation. 3. C* is the dimension for extended drain pan. (option) C C* Ceiling Concealed with Down Return Plenum Water outlet G3/ Water Inlet G3/ Drain Connection R3/ YGFC--CD-(3,)-S(H) YGFC-3-CD-(3,)-S(H) YGFC--CD-(3,)-S(H) YGFC--CD-(3,)-S(H) YGFC-8-CD-(3,)-S(H) YGFC--CD-(3,)-S(H) YGFC--CD-(3,)-S(H) A B C Note:. Right hand unit shown, left hand unit opposite.. The plenum connection (down plenum or back plenum) can be changed in according to field installation. 3. C* is the dimension for extended drain pan. (Option). The dimension in () refer to plenum with filter. C* D

19 Dimensions (Cont.') Ceiling Concealed with Back Return Plenum Water outlet G3/ Water Inlet G3/ Drain Connection R3/ YGFC--CB-(3,)-S(H) YGFC-3-CB-(3,)-S(H) YGFC--CB-(3,)-S(H) YGFC--CB-(3,)-S(H) YGFC-8-CB-(3,)-S(H) YGFC--CB-(3,)-S(H) YGFC--CB-(3,)-S(H) A B C Note:.Right hand unit shown, left hand unit opposite..the plenum connection (down plenum or back plenum) can be changed in according to field installation. 3.C* is the dimension for extended drain pan. (Option).The dimension in () refers to plenum with filter. C* D Ceiling, Vertical Exposed Water outlet G3/ Water Inlet G3/ Drain Connection R3/ A B C D YGFC--VE(CE)-(3, ) 95 8 YGFC-3-VE(CE)-(3, ) YGFC--VE(CE)-(3, ) YGFC--VE(CE)-(3, ) YGFC-8-VE(CE)-(3, ) YGFC--VE(CE)-(3, ) YGFC--VE(CE)-(3, )

20 Dimensions (Cont.') Vertical Concealed Water outlet G3/ Water Inlet G3/ Drain Connection R3/ YGFC--VC-(3, ) YGFC-3-VC-(3, ) YGFC--VC-(3, ) YGFC--VC-(3, ) YGFC-8-VC-(3, ) YGFC--VC-(3, ) YGFC--VC-(3, ) A B

21 Wiring Diagram CC/CB/CD/CE/VE/VC Wiring Install Connection Unit junction Box 3 Speed Switch High Speed Speed Speed Red Blue Black MOTOR Yellow Power Line Neutnal Line Ground Red Blue MOTOR Black Yellow Warning: Connect lines correctly, otherwise, it will cause motor damage. Note:. Multiple fan coil units can not be controlled by one switch.. Power line and neutral line can t be connected wrong. 9

22 *Subject to change without notice. YORK INTERNATIONAL FORM NO.: C.YGFC(GZF)() York International (Northern Asia) Ltd. Unit 8, /F., Tower, World Trade Square, 3 Hoi Bun Road, Kwun Tong, Kowloon, Hong Kong. Tel: (85)3398 Fax: (85)3398

Chilled Water Fan Coil Unit

Chilled Water Fan Coil Unit Chilled Water Fan Unit Model: HFCF02~HFCF14 Airflow Range: 200~2400m 3 /h Features and Benefits The Best Choice for Comfort The Best Results - Quiet Comfort Low noise permanent split capacitor motor. Metal

More information

Chilled Water Fan Coil Unit. Model:HFCA Size 03~14

Chilled Water Fan Coil Unit. Model:HFCA Size 03~14 Chilled Water Fan Coil Unit Model:HFCA Size 03~4 The Best Choice for Comfort =The Best Results Quiet Comfort Slope coil avoid air flow perpendicular impact Low noise permanent split capacitor motor Metal

More information

QZSR Fan Coil. Key features. Specifications. Product code example Cassette Unit QZSR, QZSR-13-2-2-1

QZSR Fan Coil. Key features. Specifications. Product code example Cassette Unit QZSR, QZSR-13-2-2-1 Key features Vertical or horizontal installation Cooling ( pipes) Heating ( pipes or electrical heater) Available pressure up to 80 Pa ECM version for low energy consumption In line with innovative trends

More information

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC Technical Concept Filter Fan Unit SILENT Type SILENT AC Type SILENT EC Filter Fan Unit SILENT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean

More information

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS

More information

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None 1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements

More information

Transformer oil cooler ALFA A02

Transformer oil cooler ALFA A02 A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using

More information

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of

More information

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

Installation Manual CLIFC Fan & Coil Variable Speed

Installation Manual CLIFC Fan & Coil Variable Speed Installation Manual CLIFC Fan & Coil Variable Speed General Description GENERAL DESCRIPTION FANS EQUIPMENT Totally Factory assembled within the unit all piping, wiring, and required controls for operation

More information

8W! consumption. 26,5 db IP45. BATHROOM EXTRACT FANS SILENT-100 DESIGN 3C Series

8W! consumption. 26,5 db IP45. BATHROOM EXTRACT FANS SILENT-100 DESIGN 3C Series SILENT-1 Series Range of axial extractors with airflow rates of 85 m 3 /h, for connection to 1 mm diameter circular ducting. Motor mounted on silent-elastic-blocks which absorb the vibrations and allow

More information

Under sill units. Type FSL-B-ZAS

Under sill units. Type FSL-B-ZAS .1 X X testregistrierung Under sill units Type, heat recovery Centrifugal fan Adaptive heat recovery damper HYGIENISCH GETESTET V DI 022 Tested to VDI 022 Secondary air unit for supply air and extract

More information

TFSR & TFSK Roof Fans

TFSR & TFSK Roof Fans Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans TFSR & TFSK Roof Fans With swing-out function 2 I TFSR/TFSK TFSR & TFSK Roof

More information

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water 2 to 15 tons Water-Cooled and Chilled Water Unique Solutions for Challenging HVAC Projects Your Choice for Limited Space Applications Water-Cooled Chilled Water The VertiCool Space Saver allows installation

More information

UDSA - UDSBD unit heater

UDSA - UDSBD unit heater APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer

More information

FAN COIL UNIT SOFTWARE User Manual

FAN COIL UNIT SOFTWARE User Manual User Manual Thanks for using Tiba fan coil units' selection software. To start the selection process to software selection there are some steps we need to follow: Front page: 1. Only selection 2. Performance

More information

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

HVAC Systems: Overview

HVAC Systems: Overview HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct

More information

TWE+TTA TWE+TWA 6.25-20 T.R.

TWE+TTA TWE+TWA 6.25-20 T.R. TWE+TTA TWE+TWA 6.25-20 T.R. Main features : TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drive centrifugal fan motor. Aluminium fin coil with copper-tubes.

More information

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series SWIMMING POOL AIR-HANDLING UNITS KU-DB Series ME20 proklima 2 SWIMMING POOL AIR-HANDLING UNITS - KU-DB Series proklima 3 TABLE OF CONTENTS 1 Introduction page 3 2 Features page 4 SWIMMING POOL AREA t =

More information

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,

More information

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000

More information

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here. COIL INPUT SCREENS Example of a Water Coil Input Screen: (*please see the appendix for an example of an Evaporator, Steam or Condenser Coil input screen) PHYSICAL DATA ITEM NUMBER: Always use a 1 through?

More information

Chilled Water Precision Air Conditioner For Critical Application

Chilled Water Precision Air Conditioner For Critical Application AIRSYS-P-SC-OPTIMA-HD-E1304V01.2 HD Chilled Water Precision Air Conditioner For Critical Application Cooling capacity: 42.1kW~161.5kW OPTIMA product family is designed for medium to large data center.

More information

KONRAD. Hybrid Fancoil Series

KONRAD. Hybrid Fancoil Series KONRAD Hybrid Fancoil Series Konrad is an innovative radiator which cools you down and warms you up. Indeed, it cools in summer and heats in winter; but it makes it with an incomparable quietness. Thanks

More information

UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01

UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01 GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

Advances in Gas Cooler Design and the New Gas Cooler Product Selector

Advances in Gas Cooler Design and the New Gas Cooler Product Selector Advances in Gas Cooler Design and the New Gas Cooler Product Selector Simon Jones Engineering Manager Sean Armitage Sales Manager Introduction GEA Searle Over 90 years experience in the design and manufacture

More information

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system. ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2

More information

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-211 REV. 3 Supersedes Form No. C11-211 Rev. 2 INDOOR COILS RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................

More information

Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFL- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] Rheem Indoor Coils are designed for use

More information

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way

More information

CADB and CADT-D / DI / DC Series

CADB and CADT-D / DI / DC Series HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised

More information

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

SINGLE PACKAGE VERTICAL AIR CONDITIONERS SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,

More information

marine/bespoke split applications

marine/bespoke split applications split applications marine/bespoke evaporators, condensers and split air conditioning systems suitable for a multitude of applications such as coastal, extreme high and low ambients, harsh dusty environments

More information

Cool Design for Homes and Offices

Cool Design for Homes and Offices AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive, and designed to fit any space: there are Cool Design for Homes and Offices a lot of reasons why Air Blue air conditioners

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05 TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation

More information

CRAC Precision climate control units for data centres

CRAC Precision climate control units for data centres CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have

More information

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-212 REV. 1 Supersedes Form No. C11-212 INDOOR COILS RCFM- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES

More information

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts Lo w p r o f i l e small air handlers and extract fan units Duties to 0.55m 3 /sec Available with the Electroline fitted control panel Ceiling void friendly - unit heights from 190mm to 350mm Airline VES

More information

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-211 REV. 7 Supersedes Form No. C11-211 Rev. 6 INDOOR COILS RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM

More information

O-I DUBI PLANT FANS Quotation Spec Data & Specifications

O-I DUBI PLANT FANS Quotation Spec Data & Specifications TECHNICAL DATA O-I DUBI PLANT FANS Quotation Spec Data & Specifications 1 page for the global informations + 12 pages for the fans data Revision 2 end april Global informations: These fans are a replacement

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03 Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03 Aluminum Cooling Coil Nomenclature 4 C X C B 0 3 6 C C 3 C U A A Refrigerant Type 4 - R410A Product Family T-Premium (Heat Pump or Convertible

More information

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application Total Heat Versus Sensible Heat Evaporator Selection Methods & Application Scope The purpose of this paper is to provide specifying engineers, purchasers and users of evaporators in industrial refrigeration

More information

Once you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product.

Once you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product. COOLING FAN REQUIREMENTS CALCULATIONS Determining System Impedance Determining the actual airflow produced by a fan mounted in an enclosure is much more difficult than calculating the airflow required.

More information

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL Drawing : - TPC337 Issue : - 2 Date : - 24/01/12 UNPACKING Thank you for deciding to purchase an EIPL Industrial dehumidifier. Like the many tens of thousands

More information

Performance Rating of Room Fan- Coils

Performance Rating of Room Fan- Coils ANSI/AHRI Standard 440 with Addendum 1 (Formerly ARI Standard 440) 2008 Standard for Performance Rating of Room Fan- Coils ANSI/AHRI STANDARD 440-2008 WITH ADDENDUM 1, PERFORMANCE RATING OF ROOM FAN-COILS

More information

Preventive Maintenance. State Energy Assessment Workshop By: DTE Energy Partnership & Services

Preventive Maintenance. State Energy Assessment Workshop By: DTE Energy Partnership & Services Preventive Maintenance State Energy Assessment Workshop By: DTE Energy Partnership & Services Do you know? World wide research has shown that one of the reasons causing 80% of the accidents is deficient

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED

More information

Energy Saving ECM Motors and Fans. 2010 Ventilation Catalogue

Energy Saving ECM Motors and Fans. 2010 Ventilation Catalogue Energy Saving ECM s and Fans 2010 Ventilation Catalogue CONTENTS For ellington, sustainability is about delivering products at competitive prices while preserving the environment for future generations.

More information

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008 Installation Manual Rental Services Air Handling Units July 2008 CHS-SVN01A-EN Copyright 2008 Trane All rights reserved This document and the information in it are the property of Trane and may not be

More information

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK CL - CH - CK Direct driven solution for industry Proven technology, solid construction The CL - CH - CK units are directly driven air-cooled, single

More information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor

More information

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1 SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH

More information

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm) UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery

More information

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-213 REV. 4 Supersedes Form No. C11-213 Rev. 3 INDOOR COILS RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM

More information

squrboxbox heat recovery squrboxbox I technical information

squrboxbox heat recovery squrboxbox I technical information heatrecoveryrange heat recovery squrboxbox I technical information squrboxbox Low depth high performance Only 350mm deep & up to 430l/s, providing the most effective low depth solution. Quietest solution

More information

Low Profile Unit Cooler

Low Profile Unit Cooler Super-Flo Now available with EC Motors High Efficiency / High Reliability Low Profile Unit Cooler Publication No. 411.4 November, 2008 S A N I T A T I O N F O U N D A T I O N A L N A T I O N Air Defrost

More information

APC APPLICATION NOTE #112

APC APPLICATION NOTE #112 #112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.

More information

HP switch LP switch Discharge thermo Comp. Surface thermo

HP switch LP switch Discharge thermo Comp. Surface thermo 1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer

More information

GCS16 GCS20 WARNING CAUTION

GCS16 GCS20 WARNING CAUTION Service Literature Corp. 0110 L6 Revised 12 2004 GCS16/GCS20 SERIES UNITS GCS16 GCS20 2 to 5 Ton GCS16/20 series units in the 2 to 5 ton (7.0 to 17.0 kw) cooling size are packaged combination gas heat

More information

Maintenance for Energy Efficiency

Maintenance for Energy Efficiency Maintenance for Energy Efficiency Institute of Hospital Engineering, Australia (IHEA) Seminar Asset Management & Energy Efficiency Exclusive Trane distributor Australia/New Zealand. The TRANE trade mark

More information

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4. AquaFREE System Technical Catalogue Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.5/6)H(1/3) Specifications in this manual are subject to change without notice

More information

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES After studying this unit, the reader should be able to explain the purpose of the condenser in a refrigeration system. describe differences

More information

CoolTeg Plus Chilled Water (CW) version: AC-TCW

CoolTeg Plus Chilled Water (CW) version: AC-TCW version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420

More information

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power: PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV

More information

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans IN-LINE MIXED LOW DUT ANS ultra-quiet Series (16 to 1 models) Low profile Mixed-flow fans with sound-absorbent insulation. Extremely quiet. ertified of Approval Noise Abatement Society (TD-35, TD-5, TD-8

More information

Fresh Air Enclosure Cooling Filter Fans

Fresh Air Enclosure Cooling Filter Fans 763.576.3200 SPEC-00306 K763.422.2211 COOLING FRESH AIR ENCLOSURE COOLING FILTER FANS Fresh Air Enclosure Cooling Filter Fans TFP SIDE-MOUNT TFP10 215 CFM (365 m3/hr.) TFP6 140 CFM (238 m3/hr.) TFP4 55

More information

Explosion-Proof Electric Unit Heaters

Explosion-Proof Electric Unit Heaters Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,

More information

CE6500 Energy Recovery Ventilator

CE6500 Energy Recovery Ventilator ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge

More information

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling Data Center Design Guide featuring Water-Side Economizer Solutions with Dynamic Economizer Cooling Presenter: Jason Koo, P.Eng Sr. Field Applications Engineer STULZ Air Technology Systems jkoo@stulz ats.com

More information

The Ultimate Truck Stock Motor

The Ultimate Truck Stock Motor The Ultimate Truck Stock Motor What is a Rescue Motor? Universal Replacement Motor for Condenser Fan and Direct Drive Blower Applications Multi-Horsepower PSC Motors Flexible Mounting Options Permanent

More information

TEST REPORT #44. System Drop-in Tests of Refrigerant R-32 in Single Packaged Vertical Heat Pump (SPVH)

TEST REPORT #44. System Drop-in Tests of Refrigerant R-32 in Single Packaged Vertical Heat Pump (SPVH) Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #44 System Drop-in Tests of Refrigerant R-32 in Single Packaged

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402 TECHNICAL & SERVICE MANUAL SA 79G SA 99G FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-79G-A 1 851 005 18 General (50Hz) & Europe SA-99G-A 1 851 005 19 SA 79G SA 99G REFERENCE

More information

Appendix - Controllers 179

Appendix - Controllers 179 Version: 200703 Appendix - Controllers 179 -3- -4- -5- -6- -7- -8- 2. Specifications 2.1 Specifications for inverter units item Model AB182ACERA Function cooling heating Capacity kw 5.01.8--5.8 5.22.0---6.2

More information

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6 - B 1 Product Detail Engineering Data... B2 Structural Support... B6 Engineering Specifications... B9 - B 2 Engineering Data REMARK: Do not use for construction. Refer to factory certified dimensions &

More information

Installation, operation and maintenance manual TX 35A

Installation, operation and maintenance manual TX 35A Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2

More information

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03 Domestic Air Conditioner SERVICE MANUAL Model HW-05LN03 Feature Anti-mold filter Mechanical control Easy clean filters Slide chassis 4-way airflow direction 2 cool settings, 2 fan settings Serial Number:

More information

ICQ Series - square centrifugal

ICQ Series - square centrifugal product ICQ Square Centrifugal (TEFC) dimensions mm 280-710 poles & duty 4-8 / up to 4,500 L/s application High performance centrifugal fans for medium to high pressure ducted systems. ICQ Series The ICQ

More information

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S NATURAL GAS 40-130 MBH INPUT Due to continuous product improvement, specifications are subject to change

More information

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table

More information

DSRQ - DSRSQ - DSRSQ-THERM

DSRQ - DSRSQ - DSRSQ-THERM DSRQ - DSRSQ - DSRSQ-THERM Specification item: Variable geometry diffuser on 597x597 mm panel developed for rooms with high ceilings where a long throw and a high induction ratio are required. Made up

More information

SECTION 15732 AIR CONDITIONING UNIT

SECTION 15732 AIR CONDITIONING UNIT SECTION 15732 AIR CONDITIONING UNIT PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Packaged, split system air conditioning unit No. 1. 1.02 REFERENCES A. Air-Conditioning, Heating, and Refrigeration

More information

Air Source Swimming Pool Heater

Air Source Swimming Pool Heater TM ir Source Swiing Pool Heater ZHONGSHN MITIME ELECTRIC CO., LTD dd: Yandong 5th Rd, Dayan Industrial Zone, Huangpu Town, Zhongshan City, Guangdong, China Tel. +86-760-9780 Fax +86-760-978 Email: info@amitime.com

More information

Water terminals SYSCOIL MINI. Low profile centrifugal fan coil units

Water terminals SYSCOIL MINI. Low profile centrifugal fan coil units Water terminals SYSCOIL MINI Low profile centrifugal fan coil units SYSCOIL MINI Low profile centrifugal fan coil units Available accessories SYSCOIL MINI Wide range of controls Compact and characterized

More information

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER

More information

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface

More information

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as: CA SERIES T he CA Aquarius Series Console Units offer the answer to providing heating and cooling to areas where space and access is limited. Office buildings, hotel/motels, schools and assisted living

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air

More information

CEILING CASSETTE FAN COIL UNIT

CEILING CASSETTE FAN COIL UNIT CEILING CASSETTE FAN COIL UNIT Operation and Installation Manual MHCFC4W-04, 08, 12, 16 Four way ceiling cassette fan coil unit Please read this manual before using the fan coil unit. Installation and

More information

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES. QUIET-ONE Environmental Products 2000 Kickspace Heater Series Models: KS 2004, KS 2006 KS 2008, KS 2010 INSTALLATION OPERATING MAINTENANCE Please read these instructions thoroughly before beginning your

More information

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014 III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014 III.1. Large Roof Mount PN: 89-3037 Roof Mount Unit Eco 136 Parallel roof mount Air-conditioning and ventilation systems The Eco 136

More information

SPACE COOLERS. P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany.com. The leader in packaged Space Cooling.

SPACE COOLERS. P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany.com. The leader in packaged Space Cooling. SPACE COOLERS P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany.com The leader in packaged Space Cooling. 2 Table of Contents Description Space Cooler from Coil Company. A

More information

MEMBRANE VACUUM MINI PUMPS

MEMBRANE VACUUM MINI PUMPS MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free

More information

Modular Access Floor for Data Center. From Rack to Row to Room to Building

Modular Access Floor for Data Center. From Rack to Row to Room to Building Modular Access Floor for Data Center From Rack to Row to Room to Building Why using Scneider Electric modular access floor in Data Centers The evolution of modern Data Centers emphasizes specific exigencies

More information