Emergency lighting units EM series

Size: px
Start display at page:

Download "Emergency lighting units EM series"

Transcription

1 T T TC-DE TC-SE TC-TE TC-F TC- TC-DD Tc EM, 0 40 V 0/0 Hz PRO version Product description Emergency lighting supply unit with DAI interface and automatic test function For linear and compact fluorescent lamps ow-profile casing ( x 0 mm cross-section) Properties DAI interface for testing and feedback or h rated duration Compatible with all electronic ballasts (dimmable and non-dimmable) -pole technology: 4-pole lamp changeover and delayed power switching for the ballast High-frequency ac operation of the lamp Power control technology ensures maximum emergency ballast lumen factors for all lamps on a given module Gentle on the lamp thanks to permanent cathode heating in emergency mode. min. boost start for rapid heating of the lamp, more light in the startup phase and optimum lamp life Standard and high ballast lumen factor for hour types Electronic multi-level charge system Rest mode function Addressing function, patented ( EZ easy addressing ) EZ addressing tool can be supplied Deep discharge protection Short-circuit-proof battery connection Polarity reversal protection for battery Two-colour status display Maximum ballast lumen factors (BF) for all lamps s: Status of the battery Status of the lamp Charge condition Function test Service life test Batteries High-temperature cells icd or imh batteries D or Cs cells Blade terminals for simple connection Technical data Rated supply voltage 0 40 V Mains frequency 0 / 0 Hz Mains current 0 ma Rated power < 0 W Overvoltage protection 0 V (for h) Maximum operating voltage (U-OUT of the ECG) 40 V Battery charging time / h / 0 h Discharge current, Standard BF. A Discharge current, High Output BF. A eakage current (PE) 0. ma Ambient temperature ta C Max. casing temperature tc 0 C Mains voltage changeover threshold according to E 09-- Min. lamp starting temperature (emergency operation) - C of protection IP0 Article number umber of cells carton pallet Weight per pc. Rated operating time h, Standard BF EM pc(s). 4 pc(s). 0.9 kg EM 9000 pc(s). 4 pc(s). 0.9 kg EM pc(s). 4 pc(s). 0.9 kg Rated operating time h, Standard BF EM pc(s). 4 pc(s). 0.9 kg EM 9000 pc(s). 4 pc(s). 0.9 kg EM 9000 pc(s). 4 pc(s). 0.9 kg Data sheet 0/

2 È Standards, page 0 For wiring diagrams and installation examples, page 0 Article number umber of cells carton pallet Weight per pc. Rated operating time h, High Output BF EM 4 HO pc(s). 4 pc(s). 0. kg EM HO pc(s). 4 pc(s). 0. kg EM HO 9000 pc(s). 4 pc(s). 0.9 kg Specific technical data Battery charge time Charge current Initial charge Fast charge Trickle charge Rated operating time h, Standard BF EM 4 h 0 ma 0 ma 0 ma EM h 0 ma 0 ma 0 ma EM h 0 ma 0 ma 0 ma Rated operating time h, Standard BF EM 4 0 h 0 ma 0 ma 0 ma EM 0 h 0 ma 0 ma 0 ma EM 0 h 0 ma 0 ma 0 ma Rated operating time h, High Output BF EM 4 HO h 0 ma 0 ma 0 ma EM HO h 0 ma 0 ma 0 ma EM HO h 0 ma 0 ma 0 ma ACCESSO- RIES switch EM Product description For connection to the emergency lighting unit For checking the device function Article number bag carton Weight per pc. switch EM 90 pc(s). 00 pc(s). 0.0 kg Data sheet 0/

3 ACCESSO- RIES Status indication bi-colour Product description Two-colour status display Green: system OK, red: fault Article number bag carton Weight per pc. EM bi-colour 9990 pc(s). 00 pc(s). 0.0 kg EM bi-colour, high brightness 999 pc(s). 00 pc(s). 0.0 kg ACCESSO- RIES Addressing tool Product description Provides simple addressing for the EM PRO units Uses the bi-colour for device identification Article number carton Weight per pc. EM PRO addressing tool 999 pc(s). 0.0 kg Data sheet 0/

4 Ballast lumen factor (BF) in % EM for linear lamps, or h Duration h Standard h High Output h Cells 4 cells cells cells 4 cells cells cells 4 cells cells cells EM 4 EM EM EM 4 EM EM EM 4 HO EM HO EM HO Article no amp type Wattage BF in emergency lighting mode in % for rated operating time Technology and capacity icd 4 Ah D-cells imh Ah Cs-cells imh 4 Ah Cs-cells Design umber of cells T W W W 4 4 T FH 4 W W 4 W 9 W 0 T FQ 4 W W W W.. 0 W T W W 0 W 4 W W W.. 0 W Article number Assignable batteries Stick 4 Accu-iCd 4A Side by side 4 Accu-iCd 4B 999 Stick Stick Accu-iCd 4C 999 Stick Accu-iCd A 999 Stick Stick Accu-iCd C Stick Stick Accu-iCd C 999 Stick 4 Accu-iMH C 4A Stick Accu-iMH C A 9990 Stick Accu-iMH C A 9990 Stick Stick Accu-iMH C C 9990 Stick 4 Accu-iMH 4 Ah C 4A 9990 Stick Accu-iMH 4 Ah C A 999 Stick Accu-iMH 4 Ah C A 999 Stick Stick Accu-iMH 4 Ah C C 999 ote: 0 C batteries also available (see seperate datasheet at Maximum battery housing temperature 0 C. Data sheet 0/

5 Ballast lumen factor (BF) in % EM for compact lamps, or h Duration h Standard h High Output h Cells 4 cells cells cells 4 cells cells cells 4 cells cells cells EM 4 EM EM EM 4 EM EM EM 4 HO EM HO EM HO Article no amp type Wattage BF in emergency lighting mode in % for rated operating time TC-DD 0 W W 4 4 W W 4 4 W.. W.. TC-SE W W 4 W TC-DE 0 W W 4 W W TC-TE W W. /.0 / 0. (GE). /.0 / 0. (GE) / 0 W. / 0.4 / / 4.0. / 0.4 / / 4.0 / W 4 /. /.0 4 /. /.0 / 4 W.4 /..4 /. / 9 W. /.. /., /, Tc W.. 40 W.. W.4.4 TC-F W 4 W 4 W TC- W 0 4 W 4 W 4 40 W.. W Article number Assignable batteries Technology and capacity Design umber of cells Stick 4 Accu-iCd 4A Side by side 4 Accu-iCd 4B 999 icd 4 Ah D-cells Stick Stick Accu-iCd 4C 999 Stick Accu-iCd A 999 Stick Stick Accu-iCd C Stick Stick Accu-iCd C 999 Stick 4 Accu-iMH C 4A imh Ah Cs-cells Stick Accu-iMH C A 9990 Stick Accu-iMH C A 9990 Stick Stick Accu-iMH C C 9990 Stick 4 Accu-iMH 4 Ah C 4A 9990 imh 4 Ah Cs-cells Stick Accu-iMH 4 Ah C A 999 Stick Accu-iMH 4 Ah C A 999 Stick Stick Accu-iMH 4 Ah C C 999 ote: 0 C batteries also available (see seperate datasheet at Maximum battery housing temperature 0 C. The first figure is related to non-amalgam lamps, the second figure is realted to amalgam lamps (e.g. 4 / 9,). For best performance of W and W TC lamps, and especially amalgam filled lamps, we recommend the use of EM resp. EM. Data sheet 0/

6 Emergency Ballast umen Factor (EBF) in % EM, or h Duration h Standard h High Output h Cells 4 cells cells cells 4 cells cells cells 4 cells cells cells EM 4 EM EM EM 4 EM EM EM 4 HO EM HO According to E 4--: 00 The first figure is related to non-amalgam lamps, the second figure is realted to amalgam lamps (e.g. 4 / 9,). For best performance of W and W TC lamps, and especially amalgam filled lamps, we recommend the use of EM resp. EM. EM HO Article no amp type Wattage EBF in emergency lighting mode in % for rated operating time T W W W 4, T FH 4 W 4 W W 4 4 W T FQ 4 W.. 9 W.. 49 W W.. 0 W 4. 4., T W.. W.. 0 W W 9 W W.., 0 W.. TC-DD 0 W 9 9 W.. W W.. W.. W.. TC-SE W 44 9 W.. 4 W 4 TC-DE 0 W.. 9 W.0 4 W.. 0 W.0, TC-TE W W / 0. /.0 / 0. /.0 / W 0.4 /.9 / 9. /. 0.4 /.9 / 9. /. / W. / 4. /.. / 4. /. / 4 W. /.. /. / 9 W.0 /..0 /. /, Tc W.. 40 W, W.. 9, TC-F W.., 4 W , W, TC- W 4 W.., W W.4.4 W 4. 4., Data sheet 0/

7 amp current in emergency operation in ma EM, or h Duration h Standard h High Output h Cells 4 cells cells cells 4 cells cells cells 4 cells cells cells EM 4 EM EM EM 4 EM EM The first figure is related to non-amalgam lamps, the second figure is realted to amalgam lamps (e.g. / ). EM 4 HO EM HO EM HO Article no amp type Wattage amp current in emergency operation in ma for rated operating time T W W W T FH 4 W W W 9 9 W 9 T FQ 4 W 9 W W W 4 0 W T W W 9 0 W 4 4 W 0 W W W TC-DD 0 W 9 9 W W W 0 0 W 4 4 W TC-SE W W W 4 TC-DE 0 W W W W 0 0 TC-TE W / / / 4 W / / / / / W / / / / / 4 W / 9 / / 9 / / 4 W 4 / 4 / 4 / 44 W / / 4 / Tc W 40 W 9 W 9 TC-F W W 4 4 W TC- W W W 40 W 4 W Data sheet 0/

8 ing: DAI Control A DAI command from a suitable control unit can be used to initiate function and duration tests at individually selected times. Status flags are set for report back and data logging of results. When a DAI bus has not been connected or when a DAI bus is connected but the DAI default DEAY and ITERVA times have not been re-set by sending appropriate DAI commands, then the EM will conduct self-tests in accordance with the default times set within the EEPROM. These default times are factory pre-set, in accordance with the DAI standard E -0, to conduct an automatic function test every days and a duration test every weeks. Since the DEAY time is factory pre-set to Zero, all units are tested at the same time. times can be changed with a command over the DAI bus. The DEAY and ITERVA time values must be re-set when the emergency system test times are to be scheduled by a DAI control and monitoring system. ote that once the default values have been set to Zero, tests will only be conducted following a command from the control system. If the DAI bus is disconnected the EM does not revert to self-testing mode. Addressing The EM includes the new EZ easy addressing system which allows addressing and identification by using the bi-colour in conjunction with the EM PRO addressing tool. Binary address codes given by the can be simply converted to the DAI addresses 0 to. For single handed addressing using this method it is necessary to send a broadcast ident command every to 9 seconds. During this command the main fluorescent lamp will be switched off and the will flash the bit binary address preceded by a second start indication period. Functional test The time of day and frequency of the 0 seconds function test can be set by the DAI controller. The default setting is a 0 seconds test on a weekly basis. Duration test The time of day and frequency of the duration test can be set by the DAI controller. The default setting is a duration test conducted every weeks. Prolong time Prolong time can be set by the DAI controller. This is the delay time between return of the mains supply and the end of the emergency operation. The default prolong time is set as 0 minutes as specified within the DAI standard. Rest Mode Rest mode can be initiated by the DAI controller. The appropriate command should be sent after the mains supply has been disconnected and whilst the module is in emergency operation. A mains reset is required to exit the rest mode. EM does not support the re-light command via the DAI bus. switch An optional test switch can be wired to each EM. This can be used to initiate a 0 seconds function test by a short press < second. DAI Controller DAI controllers and hardware/software solutions are available from Tridonic. Please refer to the ighting controls section. Service life Average service life 0,000 hours under rated conditions with a failure rate of less than 0 %. Average failure rate of 0. % per 000 operating hours. Mechanical details Channel manufactured from galvanised steel. Cover manufactured from white pre-coated steel. bi-colour status indicator Green / red Mounting hole. mm dia ead length 000 mm Insulation rating: 90 C switch Mounting hole.0 mm dia ead length 0 mm Battery leads Quantity: red and black ength: 00 mm Wire type: 0. mm² solid conductor Insulation rating: 90 C Battery end termination: push on 4. mm receptacle to suit battery spade fitted with insulating cover Module end termination:.0 mm stripped insulation Two-piece batteries are supplied with a 00 mm lead with 4. mm receptacles at each end and insulating covers to connect the separate sticks together. Batteries Connection method: 4. x 0. mm spade tag welded to end of cell For stick packs this connection is accessible after the battery caps have been fitted. To inhibit inverter operation disconnect the batteries by removing the connector from the battery spade tag. For battery data see separate data sheet. Status indication System status is indicated by a bi-colour and by a DAI status flag. Permanent green Fast flashing green Slow flashing green Permanent red Fast flashing red Slow flashing red Double pulsing green Status System OK Function test underway Duration test underway amp fault Charging fault Battery fault Inhibit mode Accu-iCd Case temperature range 0 C to C to ensure 4 years design life Battery voltage/cell. V Capacity D 4. / 4. Ah Max. short term temperature (reduced lifetime) 0 C Packing quantity pcs. per carton Accu-iMh Case temperature range (to ensure 4 years design life).0 Ah Cs 0 C to C 4.0 Ah Cs 0 C to 0 C Battery voltage Capacity Cs. V.0 Ah 4.0 Ah Max. short term temperature (reduced lifetime) 0 C Packing quantity pcs. per carton Data sheet 0/

9 Isolation and electric strength testing of luminaires Electronic devices can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production. According to IEC 09- Annex Q (informative only!) or EEC 0-Annex A, each luminaire should be submitted to an isolation test with 00 VDC for second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal. The isolation resistance must be at least MΩ. As an alternative, IEC 09- Annex Q describes a test of the electrical strength with,00 VAC (or,44 x,00 VDC). To avoid damage to the electronic devices this test must not be conducted. ote: Basic insulation between supply and battery circuit. Electrical connections An earthed starting aid is recommended. The module should be earthed by the fixings used to attach it to the luminaire. Wiring amp/ballast/supply wire preparation: mm² 9 mm IDC interface solid wire with a cross section of 0. mm² according to the specification from WAGO Horizontal interface solid wire with a cross section of 0.0. mm² according to the specification from WAGO solid wire with a cross section of.0 mm² with an insulation diameter up to. mm strip 9 mm of insulation from the cables loosen wire through twisting and pulling Batteries// switch push terminal with button release: 0. mm². mm strip Maximum lamp lead capacitance terminals and (* hot leads) 00 pf ) terminals and 4 00 pf ) Wiring guidelines To ensure that a luminaire containing high frequency emergency units complies with E 0 for radio frequency conducted interference in both normal and emergency mode it is essential to follow good practice in the wiring layout. Within the luminaire the switched and unswitched 0 Hz supply wiring must be routed as short as possible and be kept as far away as possible from the lamp leads. This means, for example, in a linear T or T luminaire the mains wiring should be routed along one side of the luminaire body, while the wires to the emergency lamp from the emergency module are routed along the other side. oosen wire through twisting and pulling The high frequency emergency lamp wiring contains hot leads at pins and, which have high voltage to earth. These should be kept as short as possible and separated from other wiring to minimize coupling. They also have a restriction on capacitance to other wiring and earth of 00 pf, which must be observed to ensure good lamp starting. With an earth connection of the metal case of the emergency module the noise suppression can be further improved. The wiring of the earth should be kept as short as possible. Through wiring may affect the emc performance of the luminaire. ) ote: care should be taken not to exceed the total maximum lamp lead capacitance for HF ballast. eads should always be kept as short as possible. With the use of the fifth pole possible compatibility problems between the products can be prevented. Depending on the luminaire wiring the radio suppression in the emergency mode of operation can be further improved. Capacitive loading limits of lamp leads must not be exceeded. ote the capacitance of the emergency lamp leads adds to the capacitance of the leads from the ballast to the EM module when considering ballast loading. The and test switch wiring should be routed separately and kept as far away as possible from the high frequency lamp leads to avoid coupling. EM FT filter When the EM is used in a remote appli-cation, where the lamp leads and indicator leads are routed together in close proximity, it is possible to have electrical interference picked up in the indicator leads. Under certain conditions this interference can cause a lock-up of the EM micro-controller. EM FT filter 0,4 4, To overcome this problem in such applications it is necessary to fit the filter EM FT between the indicator and the EM unit. To be effective the filter must be connected close to the EM module.,, For further information please contact Tridonic. 4, 4, Technical data: Push wire terminals 0.. mm² solid conductor 0,4 Circuit diagram with EM FT filter, Article number carton pallet Weight per pcs. EM FT pieces,000 pieces 0.0 kg EM FT out in D EM D EMERGECY MODUE 4 Batteries Data sheet 0/

10 Standards acc. to E 0 acc. to E 09-- E 4-- E 04 E 0 E E IE 4 E E E IEC (according to DAI standard V) EM emergency module wiring diagrams ot for use with magnetic ballasts and switch start circuits ed line out to ballast ine in from switch eutral DAI control DAI control Permanent line out in D D EM... EMERGECY MODUE 4 ed line out to ballast ine in from switch eutral DAI control DAI control Permanent line out in D D EM... EMERGECY MODUE 4 orange () pink () Battery orange () pink () Battery eutral to ballast eutral to ballast HF BAAST U-OUT max. 40 V HF BAAST U-OUT max. 40 V amp Wiring diagram for single lamp high frequency ballasts Wiring diagram for twin lamp high frequency ballasts with terminals ed line out to ballast ine in from switch eutral DAI control DAI control Permanent line out in D D orange () pink () EM... EMERGECY MODUE Battery 4 ed line out to ballast ine in from switch eutral DAI control DAI control Permanent line out in D D orange () pink () EM... EMERGECY MODUE Battery 4 eutral to ballast HF BAAST U-OUT max. 40 V eutral to ballast HF BAAST U-OUT max. 40 V amp amp Wiring diagram for twin lamp high frequency ballasts with terminals Wiring diagram for twin lamp high frequency ballasts with terminals o connection to be made eutral DAI control DAI control Permanent line out in D D EM... EMERGECY MODUE 4 ote: All hot leads normally marked with an * should be kept as short as possible. For comprehensive wiring diagrams and instructions consult the Tridonic website orange () pink () Battery Wiring diagram for non-maintained operation Data sheet 0/

Emergency lighting units EM powerled

Emergency lighting units EM powerled M BASIC 1 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing SEV for output voltage < 60 V DC ow-profile casing (21 x 30 mm cross-section) 5-year

More information

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5 T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,

More information

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5 F ballasts T PCA T EXCE oneall lp Y, x1/ W and x1/ W EXCE T Product description Processor-controlled ballast with y inside Highest possible energy class CEMA EEI = A1 BAT 1 oise-free precise control via

More information

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W T5 TC-DEL TC-SEL TC-TEL TC-DD PC BASIC, 4 28 W Electronic ballast for system output < 25 W Product description CELMA Energy Efficiency Index A2 / A3 Nominal life time up to 50,000 h (at ta 50 C with a

More information

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, 18 80 W Compact and T5c fluorescent lamps

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, 18 80 W Compact and T5c fluorescent lamps Product description Noise-free precise control via DSI signal or switchdim CELMA energy class A1 1) Interfaces DSI switchdim Integrated SMART-Interface Functions Optimum filament heating in any dimmer

More information

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, 18 80 W Compact and T5c fluorescent lamps

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, 18 80 W Compact and T5c fluorescent lamps EXCEL oneall series Product description Noise-free precise control via DSI signal, switchdim, corridorfunction or DALI DALI-MEMORY Extended DALI commands CELMA energy class A1 1) Interfaces DALI DSI switchdim

More information

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, 14 80 W EXCEL T5

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, 14 80 W EXCEL T5 E T5 TC- PCA T5 EXCE oneall lp Y II, 1 80 W EXCE T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CEMA EEI = A1 BAT 1 oise-free precise control via I or

More information

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, 14 80 W ECO T5

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, 14 80 W ECO T5 EL PCA ECO lp Y II, 1 80 W ECO Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DALI or DSI signal, switchdim

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series Product description Independent dimmable LED control gear Constant current LED control gear Output current adjustable between 900 1,750 ma Max. output

More information

Digital gear for fluorescent lamps

Digital gear for fluorescent lamps Catalogue 2000/2001 Digital gear for fluorescent lamps Comprehensive range of literature available: Magnetic control gear for fluorescent lamps Control gear for high pressure discharge lamps Transformers

More information

LED Driver Compact dimming. Udriver LCAI 100W 900mA 1750mA ECO SR ECO series

LED Driver Compact dimming. Udriver LCAI 100W 900mA 1750mA ECO SR ECO series Udriver LCAI 100W 900mA 1750mA ECO SR ECO series Product description Independent dimmable LED Driver Constant current LED Driver Output current adjustable between 900 1,750 ma Max. output power 100 W Suitable

More information

LED light engine / OLED LED linear / area. Umodule STARK QLE G3 lens 270-1250 CLASSIC umodule QLE

LED light engine / OLED LED linear / area. Umodule STARK QLE G3 lens 270-1250 CLASSIC umodule QLE Umodule STARK QLE G3 lens 27-125 CLASSIC umodule QLE Product description Ideal for linear and panel lights Luminous flux range from 1, 1,21 lm LED system solution with outstanding system efficacy up to

More information

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer

More information

LED light engine / OLED LED compact. Umodule STARK CLE 120-2000 CLASSIC / CLE 130-2500 CLASSIC umodule CLE

LED light engine / OLED LED compact. Umodule STARK CLE 120-2000 CLASSIC / CLE 130-2500 CLASSIC umodule CLE Umodule STARK CLE 12-2 CLASSIC / CLE 13-25 CLASSIC umodule CLE Product description Designed for diffuser downlights and wallmounted luminaires Ideal to realise simple luminarie designs For easy adaptation

More information

LED control gear. LED control gear

LED control gear. LED control gear Overview System overview Product overview compact Product overview linear / area Product overview constant voltage / constant current Product / function matrix Page 10 Page 12 Page 13 Page 14 Page 15 Compact

More information

Drayton Digistat +2RF/+3RF

Drayton Digistat +2RF/+3RF /+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer

More information

LED light engine / OLED LED linear /area. Umodule STARK LLE-24-560-1300 CLASSIC STARK LLE. Ordering data

LED light engine / OLED LED linear /area. Umodule STARK LLE-24-560-1300 CLASSIC STARK LLE. Ordering data Ideal for linear and panel lights Luminous flux range from 1,25 1,57 lm LED system solution with outstanding system efficacy up to 113 lm/w, consisting of linear LED module and dimmable LED control gear

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

Single Channel Loop Detector

Single Channel Loop Detector Single Channel Loop Detector Model - LD100 Series The LD100 is a single channel inductive loop detector designed for parking and access control applications. The detector is connected to an inductive loop

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

is then retained absolutely without interruption.

is then retained absolutely without interruption. Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection

More information

basicdim DGC Compact control module

basicdim DGC Compact control module luxctrol lighting control sstem DGC Compact control module Product description Compact dimensions for luminaire installation For up to 0 DSI or LI ballasts ( per output channel) LI IN input LI/DSI output

More information

LED Driver Compact dimming. Udriver LCAI 35W 350mA 900mA ECO C ECO series

LED Driver Compact dimming. Udriver LCAI 35W 350mA 900mA ECO C ECO series Udriver LCAI 35W 350mA 900mA ECO C ECO series Product description Dimmable built-in LED Driver for LED Constant current LED Driver Output current adjustable between 350 900 ma Max. output power 35 W Nominal

More information

instabus KNX / EIB System System E F G H

instabus KNX / EIB System System E F G H Product name: Uninterruptible power supply (USV) 640 ma Design: REG (rail-mounted device) Article-no.: 1079 00 ETS search path: Gira Giersiepen / system components / power supply / power supply 640mA DRA

More information

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation

More information

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111 , GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,

More information

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)

More information

connecdim Gateway G1 Ethernet TCP/IP to DALI

connecdim Gateway G1 Ethernet TCP/IP to DALI Gateway G1 Ethernet TCP/IP to LI Independent lighting control for up to 256 LI gears on 4 LI lines Can be expanded by connecting multiple gateways on the same network Cloud based web interface for configuration

More information

ISL-540 TBTS SERIES D EMERGENCY LIGHTING EQUIPMENT

ISL-540 TBTS SERIES D EMERGENCY LIGHTING EQUIPMENT P.O. BOX 11846 TUCSON, AZ 85734 (520) 294-3292 FAX (520) 741-2837 www.iotaengineering.com INSTRUCTION MANUAL IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault

More information

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions Compact presence detector Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause

More information

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue

More information

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,

More information

EBDSPIR-PRM, EBDSPIR-PRM-IP

EBDSPIR-PRM, EBDSPIR-PRM-IP Product Guide EBDSPIR-PRM, EBDSPIR-PRM-IP Ceiling PIR presence/absence detector Overview The EBDSPIR-PRM PIR (passive infrared) presence detector provides automatic control of lighting loads with optional

More information

ST Series POWER SUPPLIES USER INSTRUCTIONS

ST Series POWER SUPPLIES USER INSTRUCTIONS Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional

More information

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D ELECTRONICS AB DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D & HIGH&VOLTAGE& FIXED&GAIN& BROADBAND & 800Vpp&60mA& 100x& DC&to&ca&200&kHz & LOW&OUTPUT&IMPEDANCE& HIGH&SLEW&RATE &

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

13 SERIES. Electronic step relays 10-16 A 13.81 13.91

13 SERIES. Electronic step relays 10-16 A 13.81 13.91 13 Electronic step relays 10-16 A 13 13.81 - Electronic step relay - Rail mount - 1 Pole 13.91 - Electronic step relay and timing step relay Switch box mount - 1 Pole Fixed time (10 minutes) timing function

More information

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output. Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling

More information

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions

More information

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access CSP Combined Series Telephone Door Entry with Proximity Keyfob Access PD-094 Issue 3 General Description The CSP series systems are combined Door Entry Telephone and Proximity Access Systems. The entrance

More information

CO2 Alarm. Operation. Application

CO2 Alarm. Operation. Application CO Alarm 100-77V AC Supply Voltage Two pre-configured alarm and control thresholds Thresholds factory set to customer requirements on dispersive infrared sensing technology Optional internal audible alarm

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains

Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation

More information

IO-RM3 3-Stage Relay Module

IO-RM3 3-Stage Relay Module Page 1 of 6 IO-RM3 3-Stage Relay Module Features: Benefits: Link selectable modes binary, heat/cool, staged or sequenced On/Off/Auto links for ease of commissioning DIN Rail mounting Fault finding LED

More information

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up

More information

EBDSPIR-DD, EBDSPIR-DD-IP

EBDSPIR-DD, EBDSPIR-DD-IP Product Guide EBDSPIR-DD, EBDSPIR-DD-IP Ceiling PIR presence detector DALI / DSI dimming Overview The EBDSPIR-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with

More information

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions Disabled Toilet Alarm Installation & Operating Contractor Pack Installation & Operating Instructions 1 Overview The Channel Safety Systems Disabled Toilet alarm contractor Packs are an efficient way of

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options. MX MANUAL CONGRATULATIONS to the purchase of your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest

More information

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1. USER GUIDE Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator Version 1.3 DM Engineering 2174 Chandler St. Camarillo, CA 91345-4611 805-987-7881 800-249-0487

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Operating Instructions

Operating Instructions Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect

More information

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.

More information

Combi switchbox with integrated 3/2 way pilot valve

Combi switchbox with integrated 3/2 way pilot valve H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled

More information

User s Manual Before using the inverter, you need to read and save the safety instructions.

User s Manual Before using the inverter, you need to read and save the safety instructions. User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information

More information

ABB i-bus KNX SA/S Switch Actuators Product Manual

ABB i-bus KNX SA/S Switch Actuators Product Manual ABB i-bus KNX SA/S Switch Actuators Product Manual Contents Contents Page 1 General... 5 1.1 Using the product manual...5 1.1.1 Structure of the product manual...6 1.1.2 Notes...6 1.2 Product and functional

More information

Installation and User Guide

Installation and User Guide Installation and User Guide 458-UNI8 8-Channel Universal Dimmer Module Introduction The 458/UNI8 is an 8-channel universal, digital transistor, dimmer module. Each channel s mode can be selected for either

More information

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

LED DIMMING A HELPFUL GUIDE...

LED DIMMING A HELPFUL GUIDE... LED DIMMING A HELPFUL GUIDE... Introduction There are five types of dimming control interfaces described in this document: 2-Wire Forward Phase, 2-Wire Reverse Phase, 3-Wire (Lutron), 4-Wire (0 10V), and

More information

T7560A,B,C Digital Wall Module

T7560A,B,C Digital Wall Module T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital

More information

www.ringautomotive.co.uk Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

www.ringautomotive.co.uk Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A SmartChargePro7 RSCPR7-12v, 7A SmartChargePro10 RSCPR10-12v, 10A SmartChargePro15 RSCPR15-12v, 15A SmartChargePro25 RSCPR25-12v, 2 / 6 / 12 / 25A SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A SmartChargePro50

More information

EXTERNAL DIMENSIONS AND PARTS

EXTERNAL DIMENSIONS AND PARTS FX2N-4DA SPECIAL FUNCTION BLOCK USER S GUIDE JY992D65901A This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX2N-4DA special

More information

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC900300000

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC900300000 Manual EN BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC900300000 Contents EN 1.Important safety instructions... 2 2. Installation... 2 3.Product

More information

INSTALLATION & SERVICE MANUAL. Display Panel

INSTALLATION & SERVICE MANUAL. Display Panel INSTALLATION & SERVICE MANUAL Display Panel The PowerLine EMS TM is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed

More information

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

TS510 & TS500. Installation & User Guide. Compatible Equipment

TS510 & TS500. Installation & User Guide. Compatible Equipment Installation & User Guide Compatible Equipment TS510 REM - Remote Keypad 9040 - Loudspeaker DC54/58 - Digital Communicator SD1+ - Speech Dialler 496525 Issue A 1 of 10 TS510 and TS500 Overview Introduction

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1 Product manual ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1 Intelligent Installation Systems This manual describes the function of the DALI-Gateway DG/S 8.1 with the application program Dim Slave Lightscenes

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

MANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options.

MANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options. MANUAL CONGRATULATIONS on the purchase of your new professional switch mode battery charger and tester. This charger and tester is included in a series of professional chargers from CTEK Sweden AB and

More information

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK Security Door Controls 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP

More information

T5 Watt-Miser Linear Fluorescent lamps

T5 Watt-Miser Linear Fluorescent lamps GE Lighting T5 Watt-Miser Linear Fluorescent lamps DATA SHEET T5 Watt-Miser High Efficiency 13W, 20W, 26W, 33W T5 Watt-Miser High Output 21W, 36W, 46W, 51W, 76W Product information T5 Watt-Miser lamps

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 6mm R SNC, SLE G4 10mm R SNC umodule SLE ESSENCE

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 6mm R SNC, SLE G4 10mm R SNC umodule SLE ESSENCE w LED light engine / OLED Product description For general lighting application Typ. luminous flux category: 3/6/8/1,2 lm High efficacy up to 133 lm/w for the LED module at tp = 25 C Small LES (light emitting

More information

DALI RC BASIC SO. Control unit Operating instructions

DALI RC BASIC SO. Control unit Operating instructions DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display RoHS Can be integrated with a vacuum unit, Series

More information

Switching Power Module

Switching Power Module 369357e 1 06.22.16 Description Provides capability for a zone on a GRAFIK Eye control unit (or other product) to switch a fully loaded circuit of lighting. May be used to switch incandescent, electronic

More information

Relés e Contatores de Estado Sólido SIRIUS

Relés e Contatores de Estado Sólido SIRIUS Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico

More information

Operating Instructions

Operating Instructions D-TEK Vehicle Loop Detector Operating Instructions This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment you are connecting this product

More information

Transmitter Actuator 230V wave UP 560. Operation

Transmitter Actuator 230V wave UP 560. Operation Transmitter ctuator 230V wave UP 560 5WG3 560-201 Product- and pplication Description Diagram The transmitter actuator 230V wave UP 560 (Diagram ) is a flush-mounted device with radio communication for

More information

How To Read A Pipe From A Sensor

How To Read A Pipe From A Sensor Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing

More information

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

LIEBERT VNSA Installation Sheet

LIEBERT VNSA Installation Sheet LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display

More information

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information