n Choice of equipment SP 58 Index of protection: IP 2X - IP 2XC - under front plate

Size: px
Start display at page:

Download "n Choice of equipment SP 58 Index of protection: IP 2X - IP 2XC - under front plate"

Transcription

1 SP fuse carriers with protected terminals SP fuse carriers with protected terminals n Choice of equipment Maximum cartridge rating Type Rated current 400 V± 0 V± 690 V± gg am gg am gg am SP 51 A SP 58 0 A (125 A in 400 V) These values are standardized according to IEC 269-2/2-1 They can be reduced or increased under certain specific applications Index of protection: IP 2X - IP 2XC - under front plate Conform to IEC Veritas approved Height under front plate 44 mm Mixed socket screw head for easier cable clamping Screw or rail and 1 mounting Pack Cat.Nos SP 51 for HRC fuses 14 x 51 Without microswitch Connection No of P 1 x 5 mm P or P 2 x 16 mm P + equipped neutral 6 With 5 A - 2 V± changeover micro-switch Cartridge presence, prebreak and device against single-phase operation 1 x 5 mm P or x 16 mm 2 modules SP 58 for HRC fuses 22 x 58 Without microswitch Connection No of modules P 1 x mm P or P + equipped neutral 2 x 25 mm 2 8 With 5 A - 2 V± changeover micro-switch Cartridge presence, prebreak and device against single-phase operation 1 x mm P or 6 2 x 25 mm 2 Link handle For SP 51 or SP 58 Length 00 mm, can be cut to required length Equipment derating Recommended for equipment exposed to high temperatures: Ambient temperature over 5 C: derate fuse by one rating per C (UTE C / IEC 94) Side-by-side equipment and simultaneous function 2 - devices 0.9 x ln 4-5 devices 0.8 x ln devices 0.7 x ln devices 0.6 x ln This coefficient is to be applied on the nominal rating of the base (IEC 49-1) Uninterrupted usage: it may be necessary to upgrade the bases by one size n Dimensions (mm) J W H G 44 E N A C B V L Ø4.4 B1 B2 A B B 1 B 2 C E G H J 1P 2P/P 1P SP SP J L N U V W 2P P 4P 1P 2P P 4P 1P 2P/P SP SP A C B L U V Ø4.4 B2 B1 Spacing unit (p. 179) 118

2 SPX and SPX-V selection chart SPX blade type isolators (p. 120) Mounting on plate Type Cat.Nos Nominal current In Size (blade type cartridge fuses) SPX P A 000 (OOC) SPX 00 1-P A 00 SPX 1 2-P A 1 SPX P A 2 SPX -P A Mounting on mm collector rail SPX P A 000 (OOC) SPX 00 1-P A 00 SPX 1 2-P A 1 SPX P A 2 SPX -P A SPX-V isolators with vertical blades (p. 122) Mounting on collector rail support Type Cat.Nos Nominal current In Size (blade type cartridge fuses) SPX-V 00 1-P A - mm rail 00 SPX-V 00 1-P (1) 52 1 A - 0 mm rail 00 SPX-V 1 2-P A mm rail 1 SPX-V P A mm rail 2 SPX-V -P 52 1 A mm rail (1) Isolators SPX-V 00 1 can be mounted on 185 mm collector rail by adding the 52 (single) or (double) adaptators Red catalogue numbers : New products 119

3 SPX AND SPX-V Protection plus on-load breaking >>> Fuse carriers for blade type fuses, designed to protect against short-circuits and overloads, connect and disconnect electric circuit parts without load or at full load. SPX isolators with blade type cartridge fuses, for DIN rail plate or mm distance collector rail Accessories (p. 121) Technical characteristics (p. 12) Dimensions (p ) Pack Cat.Nos SPX blade type isolators SPX-V fuse carrier Fuse carriers in two versions: - SPX in-line fuse carriers - SPX-V vertical fuse carriers SPX fuse carrier Allow maintain switching selectivity Two connection systems: terminals or collector rail Conform to standard IEC/EN 947- enables safe handling while energised protection against accidental contact fuse can be checked through transparent window voltage control via small opening in window sealable cover simultaneous switching on all poles, 10 mechanical operations cover position indicated by auxiliary contact (accessory) screw connection for lug interchangeable connection accessories 4 types of connection possible: flush-mounted terminals (SPX 000) with lugs (SPX 00-) flat connections (included with the SPX 000, as an accessory for SPX 00-) prism connections (as accessory for SPX 00-) Mounting: on plate on DIN rail on mm collector rail: on 5 or mm thick rails for models SPX 000, SPX 00 on mm rails for models SPX 1, SPX 2, SPX with installation kit for models SPX 1 and SPX 2, mounting on 5 mm thick rails possible Interchangeable outgoing line, via top or bottom The blade type fuses are available separately Mounting Mounting Nominal Size Connection on plate on collector current rail In A 000 Connection cr-sect mm A 00 With M8 sleeve A 1 With M sleeve A 2 With M sleeve A With M12 sleeve Blade type cartridge fuses (p. 14) XL mounting accessories (p. 20, 219 and 2) 120 These products are part of protection and distribution systems > See p Red catalogue numbers : New products

4 SPX and SPX-V accessories Dimensions (p. 126) Pack Cat.Nos Cage terminals for SPX and SPX-V Flat terminals for flexible copper rail Conductor: flexible or rigid multicore copper cables Cross-section Conductor Flexible rail SPX size (mm 2 ) (mm) x x x x 7-20 Prism terminals for flexible copper rail Conductor: flexible or rigid multicore copper and aluminium cables Cross-section Conductor Flexible rail SPX size (mm 2 ) (mm) x x x x 20 Extension connector with inputs Fix with M8 screws SPX size inputs 00 for mm 2 wires Terminals shields Fix at top or bottom of isolator Output SPX size With installation plate With collector rail For all types For all types For all types Connection terminals to feed the bars, for SPX and SPX-V Collector rail system:, 0 and 185 mm Prism terminals for longitudinal feed For flexible copper rail Conductor: flexible or rigid multicore copper and aluminium cables Cross-section Conductor Bar (mm 2 ) (mm) x x x 5 Flat terminals for flat bars For copper and aluminium rigid or fl exible fl at bars Size Bar thickness In (mm) (mm) (A) x x x x x x x 0 12 Pack Cat.Nos Connection terminals to feed the bars, for SPX and SPX-V (continued) Universal connection terminals for flexible copper rail Conductor: flexible or rigid multicore copper and aluminium cables Conductor Bar thickness In (mm) (mm) (A) Signalling contact for SPX and SPX-V To indicate the status of the cover Changeover contact SPX size 5 A 2 V AC; 4 A 0 V DC 000, 00, 1, 2, Lockable faceplate for SPX In closed position, the cover can be locked For 4-7 mm padlocks SPX size , 2, Kit for fixing on TH 5 for SPX SPX size For 1 isolator 000 Collector rail supports for mm phase offset Isolating support for 12, 15, 20, 25, 0 x 5 mm flat rigid copper rails For installing SPX isolators on mm collector rail Can be installed in XL 400/800/4000 distribution using vertical adaptors for uprights Tightening torque: Md = 4 Nm The internal strengthening uprights provide the necessary support Maximum temperature: Tmax = 120 C SPX size P 000, 00, 1, 2, Red catalogue numbers : New products 121

5 SPX-V vertical isolators with blade type cartridge fuse for, 0 or 185 mm collector rails SPX-V accessories Accessories (p. 121) Technical characteristics (p. 124) Dimensions (p. 127) Pack Cat.Nos SPX-V isolators with vertical blades Conform to standard IEC/EN 947- enables safe handling while energised Protection against accidental contact fuse can be checked through transparent window voltage control via small opening in window sealable cover simultaneous switching on all poles, 10 mechanical operations cover position indicated by auxiliary contact (accessory) screw connection for lug Interchangeable connection accessories types of connection possible: plate/lug (SPX-V 00-) flat connection terminals (accessory) prism connection terminals (accessory) Vertical installation Fix on mm collector rail: directly on 5 or mm thick rail for SPX-V-00 Fix on 0 mm collector rail: directly on 5 or mm thick rail for SPX-V-00 Fix on 185 mm collector rail: / 5 or mm: with adaptor (52 or 52 51) for SPX-V-00 directly for SPX-V-1- interchangeable top or bottom connection The blade type fuse carriers are available separately Collector Nominal Size Connection rail current In mm 1 A 00 With M8 lug 1 52 (1) 0 mm 1 A 00 With M8 lug mm 2 A 1 With M lug mm 400 A 2 With M lug mm A With M12 lug Blade type cartridge fuses (p. 14) XL mounting accessories (p. 2) Pack Cat.Nos Collector rail adaptor For installation of SPX-V 00 0 mm version Cat.No 52 on 185 mm collector rail system Nominal current In Output SPX V size A Single x 1 A Double 00 Cage terminals for SPX and SPX V Flat terminals for flexible copper rail Conductor: flexible or rigid multicore copper cables Cross-section Conductor Flexible rail SPX V size (mm 2 ) (mm) x x , 2, Prism connection for flexible copper rail Conductor: flexible or rigid multicore copper and aluminium cables Cross-section Conductor Flexible rail SPX V size (mm 2 ) (mm) x x 15 1, 2, Signalling contact for SPX and SPX-V To indicate the status of the cover Changeover contact SPX size 5 A 2 V AC 000, 00, 1, 2, 4 A 0 V DC Collector rail support for a phase distance of 185 mm Collector rail support for a phase distance of 185 mm Isolating support for 0- x 5- mm rigid flat copper rails For SPX-V isolators Can be installed XL 4000 enclosures by using veryical adaptors for uprights (Cat.No ) Tightening torque of the fixing screws: Md = 20 Nm Held in place by the internal uprights Maximum temperature: Tmax = 120 C SPX size P 00, 1, 2, 122 (1) Fix on 185 mm collector rail by adding a 52 or adaptor Red catalogue numbers : New products

6 SPX isolator with blade type cartridge fuses n Electrical characteristics Type SPX 000 SPX 00 SPX 1 SPX 2 SPX Size Nominal current ln 125 A 1 A 2 A 400 A A Type of current AC (- Hz) DC AC (- Hz) DC AC (- Hz) DC AC (- Hz) DC AC (- Hz) DC Nominal voltage Un 690 V AC 2 V DC 690 V AC 2 V DC 690 V AC 440 V DC 690 V AC 440 V DC 690 V AC 440 V DC Rated insulating voltage Ue 800 V 800 V 800 V 800 V 800 V Rated impulse withstand voltage Uimp 6 kv 6 kv 6 kv 6 kv 6 kv 400 VA AC 2 B AC 2 B AC 2 B AC 2 B AC 2 B 0 VA AC 22 B AC 22 B, AC 2 B (125 A) AC 2 B AC 2 B AC 2 B Category of use EN VA AC 21 B AC 22 B AC 2 B AC 2 B AC 2 B 220 V= DC 21 B; DC 22 B (0 A) DC 22 B (1 A) DC 22B DC 22B DC 22B 440 V= DC 21 B (80 A); DC 22 B (6 A) DC 21 B (1 A); DC 22 B (125 A) DC 22B DC 22B DC 22B Conditional rated short-circuit current (with gg/gl fuses) ka (peak 5 ka) ka (peak 5 ka) ka (peak 5 ka) ka (peak 5 ka) ka (peak 5 ka) Power dissipated per pole, with blade type fuse carrier (1) 9 W 12 W 2 W 4 W 48 W n Connection characteristics Type SPX 000 SPX 00 SPX 1 SPX 2 SPX Lug mounting Flat fixing for flexible copper rail, for flexible or rigid copper and multi-core cables Prism fixing for flexible copper rail, for flexible or rigid multicore copper and aluminium cables Other fixings Connection - M 8 M M M 12 Tensile strength Nm 0 5 Nm 0 5 Nm 5 40 Nm Connection mm mm mm mm 2 Tensile strength - Nm 5 6 Nm 6 8 Nm 6 8 Nm Connection mm mm mm mm 2 Tensile strength - Nm 5 6 Nm 6 8 Nm 6 8 Nm Connection inputs connector Cage terminals 1.5 mm 2 Cat.No x mm Tensile strength 4 Nm Nm (1) Fuse carrier nominal current according to standard DIN

7 SPX-V vertical isolators with blade type cartridge fuses for or 185 mm collector rails n Electrical characteristics Type SPX-V 00 mm SPX-V 00 0 mm SPX-V 1 SPX-V 2 SPX-V Size Nominal current ln 1 A 1 A 2 A 400 A A Type of current AC (- Hz) AC (- Hz) AC (- Hz) AC (- Hz) AC (- Hz) Nominal voltage Un 690 V AC 690 V AC 690 V AC 690 V AC 690 V AC Rated insulating voltage Ue 800 V 800 V 00 V 00 V 00 V Rated impulse withstand voltage Uimp 6 kv 6 kv 12 kv 12 kv 12 kv 400 V AC 2 B AC 2 B Category of use EN V AC 2 B (120 A) AC 2 B (125 A) AC 2 B AC 2 B AC 2 B 690 V AC 22 B AC 22 B AC 22 B AC 22 B AC 22 B Conditional rated short-circuit current (with gg/gl fuses) ka (peak 5 ka) ka (peak 5 ka) 0 ka (peak 220 ka) 0 ka (peak 220 ka) 0 ka (peak 220 ka) Power dissipated per pole, with blade type fuse carrier (1) 12 W 12 W 2 W 4 W 48 W n Connection characteristics Type SPX-V 00 mm SPX-V 00 0 mm SPX-V 1 SPX-V 2 SPX-V Lug mounting Flat fixing for flexible copper rail, for flexible or rigid copper and multi-core cables Prism fixing for flexible copper rail, for flexible or rigid multicore copper and aluminium cables Connection M 8 M 8 M M M 12 Tensile strength Nm Nm 0 5 Nm 0 5 Nm 5 40 Nm Connection 1,5 70 mm 2 1,5 70 mm mm mm mm 2 Tensile strength Nm Nm 6 8 Nm 6 8 Nm 6 8 Nm Connection mm mm mm mm mm 2 Tensile strength Nm Nm 6 8 Nm 6 8 Nm 6 8 Nm (1) Nominal current intensity according to standard DIN

8 SPX isolators with blade type cartridge fuses n Dimensions (mm) For installing SPX on plate SPX 000 Cat.No SPX 00 Cat.No Ø M SPX 1 Cat.No 52 04, SPX 2 Cat.No 52 06, SPX Cat.No c Cat.Nos a b c d e f g h l m p q r x M M M12 81 Installing SPX on mm collector rail SPX 000 Cat.No SPX 00 Cat.No h b l SPX SPX 2 e m p Ø 11 g 10 SPX Ø 11 x a x n a d f

9 SPX 1 Cat.No 52 05, SPX 2 Cat.No 52 07, SPX Cat.No Cat.Nos a b c d e f g h l m p q r x M M M12 81 n Accessories Cover for fixing accessories Signalling contact Cat.No 52 0 Collector rail support for a mm phase distance Cat.No b L1 x a x d L c l SPX isolators with blade type cartridge fuses (continued) c g 6 e m b h p r x a x q d f L Cat.Nos a b c d x

10 SPX-V vertical isolators with blade type cartridge fuses for or 185 mm collector rails n Dimensions (mm) Installing the SPX-V 00 Cat.No on mm collector rail 15 maxi Installing SPX-V 1 Cat.No 52 11, SPX-V 2 Cat.No and SPX-V Cat.No on 185 mm collector rail max. 457 Installing the SPX-V 00 Cat.No 52 on 185 mm collector rail using a collector rail adaptor Cat.No n Accessories Rail support for mm phase distance Cat.No Installing the SPX-V 00 Cat.No 52 on 0 mm collector rail Rail support for 185 mm phase distance Cat.No Ø Ø 1 M8 0 0 L1 L L 120 maxi Ø M

11 SPX-D fuse isolating switches 1 to A Technical characteristics and dimensions (p. 129 to 11) Pack Cat.Nos Fuse isolating switches For on-load circuit breaking To be equipped with blade type cartridge fuses for protection against overloads and short-circuits Double-break contacts with positive forced opening and closing Conform to IEC 947- Category of use AC 2 A Interlocking: - Fuse cover in ON position - Door/panel in ON position Padlocking: - Handles in OFF position (up to padlocks) Handles, auxiliary contacts and terminal shields not supplied 1 A To be equipped with blade type cartridge fuses size 00 (p. 14) Cage terminals P 1 51 P+N (neutral not protected) 2 A To be equipped with blade type cartridge fuses size 1 (p. 14) Connection with lugs P P+N (neutral not protected) 400 A To be equipped with blade type cartridge fuses size 2 (p. 14) Connection with lugs P P+N (neutral not protected) A To be equipped with blade type cartridge fuses size (p. 14) Connection with lugs P P+N (neutral not protected) Pack Cat.Nos Accessories for SPX-D isolating switches Direct handles 1/ For 1 A isolating switches 1/ For 2 A and 400 A isolating switches 1/ For A isolating switches External handles 1/ 51 2 For 1 A isolating switches Panel depth mm 1/ For 2 A and 400 A isolating switches Panel depth mm 1/ For A isolating switches Panel depth mm Extended shafts for external handles 1/ For external handle Cat.No 51 2 Panel depth mm 1/ For external handle Cat.No Panel depth mm 1/ 51 0 For external handle Cat.No Panel depth mm Auxiliary contacts 1/ NO + 2 NC For isolating switches 1 A Cat.Nos 51 00/ 1/ NO + 2 NC For isolating switches 2 A, 400 A and A Cat.Nos 51 01/02/0/11/12/1 Terminal shields 1/ 51 2 For isolating switches 2 A and 400 A Cat.Nos 51 01/02/11/12, kit of 4 shields 1/ 51 For isolating switches A Cat.Nos 51 0/1, kit of 4 shields XL mounting accessories (p. 219 and 2) 128 Bold pack quantities: Minimum quantities to be ordered Red catalogue numbers : New products These products are part of protection and distribution systems > See p

12 SPX-D fuse isolating switches 1 to A n Technical characteristics according to IEC 947- SPX-D fuses isolating switches 1 A 2 A 400 A A Fuses NH Size 00 Size 1 Size 2 Size Mounting on DIN Rail/Plate Plate Plate Plate Rated insulation voltage Ui (V) Rated dielectric strenght Hz 1 min (V) Rated impulse withstand voltage Uimp (kv) Rated thermal current Ith (40 C) (A) Rated thermal current in enclosure Ithe (A) Power dissipation with cartridge fuses (1) (W) "AC rated operational current Ie (A) (Rated frequency / Hz)" AC rated operational power Pe (kw) 400 V AC21A V AC22A V AC2A V AC21A V AC22A V AC2A V AC21A V AC22A V AC2A V AC20A V AC20A x 400 V AC2A x 0 V AC2A x 690 V AC2A Rated capacitor power (kvar) 400 V Rated breaking capacity (A) 400 V; cos =0.5" Rated making capacity (A) 400 V; cos ϕ= n Conditional short-circuit current SPX-D fuses isolating switches 1 A 2 A 400 A A Short-circuit withstand current (rms value) (2) (ka rms) Short-circuit making current (rms value) (2) (ka rms) Maximum cut-off current (peak value) (ka) Maximum power dissipation l2t (A2s x ) Minimum number of mechanical operations cycles Minimum number of electrical operations 400 V-AC2 cycles Maximum weight (/4 poles) (kg).1/4 6.6/8 6.6/8 1/15 n Connecting capacity SPX-D fuses isolating switches 1 A 2 A 400 A A Rigid cable (Cu) max. (mm ) x 185 Bar (Thickness/Width) max. (mm) /25 6/40 6/40 2 x 7/ Tightening torque (Nm) (1) Power dissipation values of cartridge fuses used in type test (2) With a protective device limiting the cut-off current and the joule integral to the indicated values 129

13 SPX-D fuse isolating switches 1 to A (continued) n Dimensions 1 A fuse isolating switches Cat.Nos 51 00/ Without handle Front view Side view Connection 5, M , A 11 1 A Dimension (mm) A M (Nm) S max Cu (mm 2 ) P P+N With direct handle Front view 49 Side view With external handle Front view 49 26,5 22,5 Side view Panel drilling 4,5 56 Ø

14 n Dimensions 2 A and 400 A fuse isolating switches Cat.Nos 51 01/02/11/12 With direct handle Front view Side view Uper view B A Ø 0 E 15 ± C D Ø 7 max 75 / min Dimension (mm) A B C D E Ø Ø T 2 A 400 A P M P+N M P M P+N M n Dimensions A fuse isolating switches Cat.Nos 51 0/1 With direct handle Front view Side view Uper view B A Ø 12, ± Ø 9 max 56 / min Dimension (mm) A B Ø T A P M12 P+N M12 11

15 HRC cartridge fuses Technical data and dimensions (p. 15 to 17) Pack Cat.Nos Cylindrical type gg Conform to EN 269-1, IEC 269-1, and 2 Veritas approved 8 x 2 (previously 8.5 x 1.5) Without With Rating Voltage ± Rupture capacity indicator indicator (Amps) (Volts) (Amps) / / Without indicator With indicator x 8 HRC Without striker With striker 14 x 51 HRC (1) 145 (1) Without striker With striker 22 x 58 HRC (1) (1) Pack Cat.Nos Cylindrical type am (motor rated) Conform to EN 269-1, IEC and 2 Veritas approved 8 x 2 (previously 8.5 x 1.5) Without Rating Voltage ± Rupture capacity indicator (Amps) (Volts) (Amps) Without indicator x 8 HRC (2) (2) Without striker With striker 14 x 51 HRC (1) 141 (1) 400 Without striker With striker 22 x 58 HRC Neutral links x 2 (previously 8.5 x 1.5) 1 00 x x x 58 Isolating fuse carriers 8.5 x 2 and x 8 (p. 167) (1) Overrating described by standards (2) Overrating not described by standards 12 Bold pack quantities: Minimum quantities to be ordered

16 blade type cartridge fuses bases Terminal shield Technical data and dimensions (p. 15 to 17) Pack Cat.Nos Bases for blade type cartridge fuses Single pole Triple pole Fibreglass reinforced polyester base Contact points are sprung except for size 4 (bolts) Bases with A - 2 V± micro-switch have a "cartridge present" signalling device for fuses with standardised striker Conform to EN and IEC 269-1, 2 - VDE Veritas approved Triple pole bases are supplied with 2 dividers Size 00-0 A Bases Mounting Connection 1 01 bare 4 rail M bare 4 rail Size 00-1 A bare screw M bare screw M8 Size 0-1 A bare screw or M with micro-switch 4 rail Size 1-2 A bare screw bare or M (1) with micro-switch 4 rail Size A bare screw or bare 4 rail M Size - A with micro-switch screw M12 Size A with micro-switch screw M16 Pack Cat.Nos Accessories Handle For all sizes Separation dividers Size 00 (for Cat.No 1 01 and Cat.No ) Size Size Size Size Size 4 Terminal shields For complete protection of blade type cartridge fuse bases Size Size Size Size 2 (1) Base with 2 micro-switches, please consult us These products are part of protection and distribution systems > See p

17 HRC blade type cartridge fuses gg/am type Technical data and dimensions (p. 15 to 17) Pack Cat.Nos Type gg (IEC) / gl (VDE) Conform to EN IEC 269-1, 2 and VDE Veritas approved Fully insulated end plate and handle lugs Rating Voltage ± Rupture capacity (Amps) (Volts) (Amps) With With indicator striker Size Size Size Size Size Size Pack Cat.Nos Type am (motor rated) Conform to EN IEC 269-1, 2 and VDE Veritas approved Fully insulated end plate and handle lugs Rating Voltage ± Rupture capacity (Amps) (Volts) (Amps) With With indicator striker Size Size Size Size Size Size

18 cartridge fuses n HRC cylindrical (p. 12) B I n Bases for blade type (p. 1) Size 00 4 Single pole Cat.Nos C R A C D M8 Size (mm) A B C D 8 x x x x Ø7.5 Ø I Size 0 to 4 (continued) Single pole with micro-switch D F E G B A S P O N H M L n Blade type (p. 14) F C B A G L E H Size (mm) A B C D D E F G H I J K L M N D2 D1 M I J K N Triple pole Cat.Nos S Ø7.5 Ø15.5 H Q J 2 O 68 N K P G Sizes 0 to 4 Single pole without micro-switch C E F M B A Size Triple pole C K D J Q Size (mm) A B C D E F G H I J K L M N O P Q R S Note: Force of striker at the beginning of stroke 1.9 kg and 1 kg at the end according to NF C 6-21 M L D 25 A n Removable handle (p. 1) R Size (mm) A B C D E F G H I J K L M N O P Q R S B B Size (mm) A B C D

19 selection charts n How to select a protection system? Depending on the type of failure, overload or short-circuit, use 2 series of data 1 Overloads: use the operating zone curves of the different protection devices. On the same row, the operating zones should not overlap 2 Short-circuits: use the i 2 t tables. The total i 2 t of the protection system the furthest downstream must be less than the upstream protection pre-arc i 2 t n Example of good selection i 2 dt in A 2 sec. cartridge upstream cartridge downstream downstream upstream C.T. pre-arc C.T. arc 20 V cos = 0.1 C.T. arc 0 V cos = 0.1 n Selection between cartridge fuses (according to IEC ) Upstream Downstream rating maximum rating determined according to class gg cartridge fuse and voltage to obtain selection (A) am gg Upstream Downstream rating maximum rating determined according to class am cartridge fuse and voltage to obtain selection (A) am gg n Motor protection Motor three-phase Cartridges 20 V 400 V 0 V x 8 14 x x 58 S. 00 S. 0 S. 1 S. 2 S. S. 4 ratings ratings ratings ratings ratings ratings ratings ratings ratings kw Hp In A kw Hp In A kw Hp In A gg am gg am gg am gg am gg am gg am gg am gg am gg am (1) (1) (1) (1) (1) 400 V max.

20 blade cartridge fuses gg and am types The gg or am types protect the conductors of electrical circuits in the event of overbad or short-circuit gg cartridge fuses: The selectivity ratio is 1.6 instead of 2 The breaking capacity of A provides full protection in the most critical situations am cartridge fuses: These cartridge fuses must be combined with a low-overload thermal protection device The breaking capacity of 0000 A from size x 8 upwards provides full protection in the most critical situations Cylindrical industrial cartridge fuses can be used to protect DC circuits supplied at up to 48 V max. n Rupture capacity curves gg type Times in seconds am type Time in seconds Current in Amps n Thermal stresses ( I 2 dt) gg type (for 0 V±) Current in Amps am type for 0 V± - except 12 A for 400 V Thermal stress in A 2 s Rating in Amps Total maximum thermal stress for critical current Pre-arc thermal stress for critical current n gg (1) type limitation curve Limited currents at peak ka Ieff Prospective short-circuit at ka rms (1) For am cartridge fuses, see technical data sheets in the Legrand e-catalogue Thermal stress in A 2 s Rating in Amps n Consumption in watts when hot, at rated current Cartridge fuses Fuse gg am ratings (A) Size 00 Size 0 to 4 Size 00 Size 0 to

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for. The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1 MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

Catalogue May 2015. EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole

Catalogue May 2015. EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole Catalogue May 2015 EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole Contents Introduction 1 Overview 1-pole 2 Overview 2-pole 3 Overview 3-pole 4 Overview 4-pole 5 Electronic Fuse Monitoring 6 Busbar

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

A project to optimise quality and energy efficiency must include metering

A project to optimise quality and energy efficiency must include metering EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

Low Voltage Products. Switches Automatic Transfer Switches

Low Voltage Products. Switches Automatic Transfer Switches Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. High energy prices,

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

FUSERBLOC. 20 to 1250 A Manual operation. 142 General Catalogue 2011-2012 SOCOMEC. Fuse combination switches

FUSERBLOC. 20 to 1250 A Manual operation. 142 General Catalogue 2011-2012 SOCOMEC. Fuse combination switches FUSERBLOC Fuse combination switches appli_8_a fuser_548_a cat fuser_59_a cat fuser_52_a cat 2 to 25 A Manual operation Function FUSERBLOC are manually operated multipolar fuse combination switches. They

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

Fuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

Fuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits Fuses for Semiconductor Protection - Cylindrical Fuses SIBA cylindrical Ultra-Rapid fuses are available in six different sizes They can be ordered with an integral striker for blown fuse indication or

More information

Breaking and protection devices

Breaking and protection devices Breaking and protection devices 05 POWER GUIDE 2009 / BOOK 05 INTRO The purpose of selecting a protection device is to perform two essential functions: to protect people and to protect trunking, while

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

Technical catalogue. Modular DIN rail components Installation contactors

Technical catalogue. Modular DIN rail components Installation contactors Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a

More information

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

Vario-Series Accessories

Vario-Series Accessories Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates

More information

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases. G Product page Inverters - Socomec G-1 Load break switches (Isolators) - Socomec G-2 Fuses - df G-3 Fuse bases Surge protection - df G-3 - Wohner G-5 - CPT G-4 - Dehn G-5 Connectors - Wieland G-6 Cable

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

D-Line Contactors, Overload Relays and Accessories

D-Line Contactors, Overload Relays and Accessories D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data. Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

SURGE PROTECTIVE DEVICES

SURGE PROTECTIVE DEVICES SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood

More information

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

Type: DILM9 10(24VDC) Article No.: 276705

Type: DILM9 10(24VDC) Article No.: 276705 Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

Breakers and Switches. Switches Switch-disconnectors OT, OETL, OTDC and OTM

Breakers and Switches. Switches Switch-disconnectors OT, OETL, OTDC and OTM Breakers and Switches Switches Switch-disconnectors OT, OETL, OTDC and OTM Switch-disconnectors OT 16...2500, OETL 3150, OTDC16...32 and OTM160...2500 Contents 4 Product overview, features 8 Technical

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

PSR The compact range Description

PSR The compact range Description Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

Manual Motor Starter MS 116 up to 16 A Technical Data

Manual Motor Starter MS 116 up to 16 A Technical Data Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

Technical data UNIBLOCK UBSF 180 625

Technical data UNIBLOCK UBSF 180 625 Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

Switching Devices Contactors and Contactor Assemblies Special Applications

Switching Devices Contactors and Contactor Assemblies Special Applications Switching Devices Contactors and Contactor Assemblies Special Applications Price groups PG 1B, 1H /2 Introduction Contactors for special applications / SIRIUS 3RT1 contactors for resistive loads (AC-1),

More information

Protection and Connection. EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole

Protection and Connection. EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole Protection and Connection EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole Contents Introduction 1 Overview 1 and 2-pole 2 Overview 3-pole 3 Overview 4-pole 4 Electronic Fuse Monitoring 5 Busbar Adapters

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

Current transformers (CT) & Shunts

Current transformers (CT) & Shunts Current transformers (CT) & Shunts Genreal overview LV CURRENT TRANSFORMERS Product selection guide Standard industrial transformers?????? TCR - TCRO range NEW 9 9 9 Current summation JVM 0 9 TCR usbar

More information

Relés e Contatores de Estado Sólido SIRIUS

Relés e Contatores de Estado Sólido SIRIUS Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico

More information

IEC 60439 >>> IEC 61439 GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

IEC 60439 >>> IEC 61439 GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES xl 3 configurable assemblies IEC 60439 >>> IEC 61439 GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES XL 3 configurable assemblies guide to migration from IEC 60439 to IEC 61439

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

3K Load-Break Switches The Program for Safety and Performance. sentric

3K Load-Break Switches The Program for Safety and Performance. sentric 3K Load-Break Switches The Program for Safety and Performance sentric Whether for reliable switching and isolation under load, or for protection against overload or short-circuits our 3K range of load-break

More information

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide - long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and

More information

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES

BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES The Edison British Style semiconductor protection fuses include a 660VAC line utilizing new filler technology. These new fuses have greatly reduced peak let-through current and energy under fault conditions

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE 380/415/690 Volt AC 50/65/80/100 ka 1. Product Guide Low Voltage Motor Control Centre CONTSTRUCTION Continuous "poured in place" gasket

More information

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W SCHRACK-INFO Any mains connection If using 4-pole. switches with 3 or 2-poles, ensure connection acc. to assembly instructions

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201 Technical Catalogue Installation Contactors Type ESB abb ABB STOTZ-KONTAKT GmbH 1 CDC 10300 C001 ABB STOTZ-KONTAKT GmbH CDC 10300 C001 Low Voltage Products and Systems We ensure safety and comfort for

More information

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51 34 Series - Slim electromechanical PCB relays 6 34 SERIES Features 34.51 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Low Voltage Switchboards The Best Technical Solution for Your Ship

Low Voltage Switchboards The Best Technical Solution for Your Ship The Best Technical Solution for Your Ship Wärtsilä SAM Electronics Optimal Power Distribution The uninterrupted supply of power to systems and consumers onboard modern ships is an extremly important matter.

More information

The complete range of consumer switchboards and switchgear

The complete range of consumer switchboards and switchgear Power Distribution The complete range of consumer switchboards and switchgear www.nhp.com.au/mod6 The MOD6 range of consumer switchboards and switchgear is specifically designed for domestic and commercial

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

Safety detection solutions

Safety detection solutions Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking

More information

ADM1TE 5/30A DIN rail single phase two wire energy meter

ADM1TE 5/30A DIN rail single phase two wire energy meter ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.

More information

40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52

40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52 Features 40.31 40.51 40.52 1 & 2 Pole relay range 40.31-1 Pole 10 A (3.5 mm pin pitch) 40.51-1 Pole 10 A (5 mm pin pitch) 40.52-2 Pole 8 A (5 mm pin pitch) PCB mount - direct or via PCB socket 35 mm rail

More information

A sophisticated design for a demanding field. prima series

A sophisticated design for a demanding field. prima series A sophisticated design for a demanding field prima series 2 nd edition 2003 prima compact horizontal interlocked sockets carefully studied A size for all versions with or without fuses. Extends horizontally

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

Rotary Disconnect Switch Specifications

Rotary Disconnect Switch Specifications Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

Soft Starter. Product Description. Ordering Code. Type Selection. Selection Guide RSG D 40 16 E 0 VD00

Soft Starter. Product Description. Ordering Code. Type Selection. Selection Guide RSG D 40 16 E 0 VD00 Soft Starter Three Phase General Purpose Soft Starters Type RSGD Soft starting and soft-stopping of 3-phase squirrel cage motors 45mm wide IP20 housing Operational Voltage: RSGD40 (220-400V), RSGD60 (220-600V)

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control

More information

DS 600. A contact free flux gate based current measurement sensor 600A rms

DS 600. A contact free flux gate based current measurement sensor 600A rms DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

How To Build A Low Voltage Capacitor Lvcp

How To Build A Low Voltage Capacitor Lvcp Low Voltage Capacitor LVCP The new choice for Power Factor Correction LVCP : the new choice for Power Factor Correction The LVCP is a compact and powerful capacitor. It offers high modularity, unmatched

More information

GE Power Controls. MiniFORM Switchboards

GE Power Controls. MiniFORM Switchboards GE Power Controls MiniFORM Switchboards MiniFORM MiniFORM MiniFORM switchboards Arrangement Modules Arrangement modules 1-6 6 Arrangement modules 7-12 7 Arrangement modules 12-14 8 Arrangement modules

More information

P System Cubicles. Certified for more safety

P System Cubicles. Certified for more safety P System Cubicles Prisma Plus LV Switchboards Certified for more safety Prisma Plus, an offer thought out for greater professionalism With the Prisma Plus P system, Schneider Electric proposes high-performance

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information