1 COMBICON compct Printed Circuit PT,5/ with 5.0 nd 7.5 mm Pitch The new PCB terminl blocks PT,5/...-5,0 re chrcterized by the proven screw connection with highly flexible conductor protection nd the extremely generous clmping spce. Solid nd strnded conductors up to 4 mm cn be connected. Thnks to its compct externl dimensions, the PT,5/...-5,0 is prticulrly suitble for building utomtion nd telecommunictions pplictions where spce is criticl. The PT,5/... is lso vilble with 7.5 mm pitch. Customized lbeling of the terminl blocks is possible. COMBICON Select The COMBICON serch engine with CAD downloding COMBICON Select the printed circuit bord connection softwre supports your workflow from the PCB nd housing lyout to the ordering process with: Systemtic nd fst selection of products Universl Internet ided engineering with extensive CAD downloding Esy-to-use e-shopping functions. select.phoenixcontct.com/combicon Phoenix Contct GmbH & Co. KG 383 Blomberg, Germny Phone Fx Locl Contct: PHOENIX CONTACT pge of 5
2 Printed Circuit PT,5/ -5,0-H 5.0 mm Pitch housing interlocking, 5 mm pitch, color: green, connection direction horizontl to the PCB PT,5/-5,0-H PT,5/3-5,0-H PT,5/4-5,0-H PT,5/5-5,0-H PT,5/6-5,0-H PT,5/7-5,0-H PT,5/8-5,0-H PT,5/9-5,0-H PT,5/-5,0-H PT,5/-5,0-H PT,5/-5,0-H PT,5/3-5,0-H PT,5/4-5,0-H PT,5/5-5,0-H PT,5/6-5,0-H () Screwdriver SZS 0,6 x 3,5 Pitch 5.0 in ccordnce with IEC/ DIN VDE Rted voltge [V] Rted surge voltge [kv] Solid / strnded / conductor sizes [mm ]/[mm ]/AWG ) / / 0- Strnded with TWIN ferrule with plstic sleeve [mm ] ) Internl cylindricl guge (IEC ) A 3 / B 3 Nominl voltge / current / conductor sizes UL/CUL: [V]/[A]/AWG 300 / 0 / 0 - ) When conductors with cross sections over 4 mm re connected, ) When using ferrules, V cn only be chieved in connection with ' #! $ # "! # # # PHOENIX CONTACT pge of 5
3 ' Printed Circuit PT,5/ -5,0-V 5.0 mm Pitch housing interlocking, 5 mm pitch, color: green, connection direction verticl to the PCB PT,5/-5,0-V PT,5/3-5,0-V PT,5/4-5,0-V PT,5/5-5,0-V PT,5/6-5,0-V PT,5/7-5,0-V PT,5/8-5,0-V PT,5/9-5,0-V PT,5/-5,0-V PT,5/-5,0-V PT,5/-5,0-V PT,5/3-5,0-V PT,5/4-5,0-V PT,5/5-5,0-V PT,5/6-5,0-V () Screwdriver, SZS 0,6 x 3,5 Pitch 5.0 in ccordnce with IEC/ DIN VDE Rted voltge [V] Rted surge voltge [kv] Solid / strnded / conductor sizes [mm ]/[mm ]/AWG ) / / 0- Strnded with TWIN ferrule with plstic sleeve [mm ] ) Internl cylindricl guge (IEC ) A 3 / B 3 Nominl voltge / current / conductor sizes UL/CUL: [V]/[A]/AWG 300 / 0 / 0 - ) When conductors with cross sections over 4 mm re connected, ) When using ferrules, V cn only be chieved in connection with # #! # # " # # PHOENIX CONTACT pge 3 of 5
4 Printed Circuit PT,5/ -7,5-H 7.5 mm Pitch housing interlocking, 7.5 mm pitch, color: green, connection direction horizontl to the PCB PT,5/-7,5-H PT,5/3-7,5-H PT,5/4-7,5-H PT,5/5-7,5-H PT,5/6-7,5-H PT,5/7-7,5-H PT,5/8-7,5-H PT,5/9-7,5-H PT,5/-7,5-H PT,5/-7,5-H PT,5/-7,5-H () Screwdriver SZS 0,6 x 3,5 Pitch 7.5 in ccordnce with IEC/ DIN VDE Rted voltge [V] Rted surge voltge [kv] Solid / strnded / conductor sizes [mm ]/[mm ]/AWG ) / / 0- Strnded with TWIN ferrule with plstic sleeve [mm ] ) Internl cylindricl guge (IEC ) A 3 / B 3 Nominl voltge / current / conductor sizes UL/CUL: [V]/[A]/AWG ) When conductors with cross sections over 4 mm re connected, ) When using ferrules, 0 V cn only be chieved in connection with ' % # "! # PHOENIX CONTACT pge 4 of 5
5 ' Printed Circuit PT,5/ -7,5-V 7.5 mm Pitch housing interlocking, 7.5 mm pitch, color: green, connection direction verticl to the PCB PT,5/-7,5-V PT,5/3-7,5-V PT,5/4-7,5-V PT,5/5-7,5-V PT,5/6-7,5-V PT,5/7-7,5-V PT,5/8-7,5-V PT,5/9-7,5-V PT,5/-7,5-V PT,5/-7,5-V PT,5/-7,5-V () Screwdriver SZS 0,6 x 3,5 Pitch 7.5 in ccordnce with IEC/ DIN VDE Rted voltge [V] Rted surge voltge [kv] Solid / strnded / conductor sizes [mm ]/[mm ]/AWG ) / / 0- Strnded with TWIN ferrule with plstic sleeve [mm ] ) Internl cylindricl guge (IEC ) A 3 / B 3 Nominl voltge / current / conductor sizes UL/CUL: [V]/[A]/AWG ) When conductors with cross sections over 4 mm re connected, ) When using ferrules, 0 V cn only be chieved in connection with "! # % # TNR: / Phoenix Contct 005 PHOENIX Phoenix CONTACT Contct pge 5 of 5
MICRO COMBICON Headers for Through Hole Reflow Applications MC(V) 0,5/ G-2,5 THT 2.5 mm Pitch
MICRO COMBICON Heders for Through Hole Reflow Applictions MC(V) 0,5/ G-2,5 THT The consistent use of Through Hole Reflow plug connectors hs lso mde it necessry to extend the COMBICON THR rnge to include
More informationGMKDS 3/ 3-7,62. Extract from the online catalog. Order No.: 1731734
Extract from the online catalog GMKDS 3/ 3-7,62 Order No.: 1731734 The illustration shows a 2-position version PC terminal block, Nominal current: 24 A, Nom. voltage: 500 V, Pitch: 7.62 mm, Number of positions:
More informationPC 4/ 4-ST-7,62. Extract from the online catalog. Order No.: 1804920
Extract from the online catalog PC 4/ 4-ST-7,62 Order No.: 1804920 The figure shows a 5-pos. version of the product Plug component, nominal current:, rated voltage: 400 V, pitch: 7.62 mm, no. of positions:
More informationPC 4/ 2-ST-7,62. Extract from the online catalog. Order No.: 1804904
Extract from the online catalog PC 4/ 2-ST-7,62 Order No.: 1804904 The figure shows a 5-pos. version of the product Plug component, Nominal current: 20 A, Nom. voltage: 400 V, Pitch: 7.62 mm, Number of
More informationPC 4/ 5-STF-7,62. Extract from the online catalog. Order No.: 1828278
Extract from the online catalog PC 4/ 5-STF-7,62 Order No.: 1828278 The figure shows a 5-pos. version of the product Plug component, Nominal current: 20 A, Nom. voltage: 400 V, Pitch: 7.62 mm, Number of
More informationMKDSN 1,5/ 3-5,08. Extract from the online catalog. Order No.: 1729131
Extract from the online catalog MKDSN 1,5/ 3-5,08 Order No.: 1729131 The figure shows a 10-position version of the product PC terminal block, Nominal current: 13.5 A, Nom. voltage: 250 V, Pitch: 5.08 mm,
More informationSpring Cage Feed-Through Terminal Blocks ST
Spring Cage Feed-Through Terminal Blocks ST The product family ST with the new spring cage system "mini spring" is extremely space-saving. Space is saved thanks to a clearly smaller spring system without
More informationElectronic housing BC for distributor boards
Electronic housing BC for distributor boards The requirements of modern building automation grow constantly and change with regard to comfort, control, intelligent linking of systems and their communication
More informationDEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050
Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage
More informationFeed-through terminal block - SSK 110 KER-EX - 0502058
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid
More informationPower Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
More information2. VOLTAGE TRANSFORMERS Support type Support type with fuse Touch-proof type
2. VOLTGE TRSFORMERS Support type Support type with fuse Touch-proof type 16 Instrument trnsformers Medium voltge indoor 2. VOLTGE TRSFORMERS ITRODUCTIO Voltge trnsformers reduce the voltge in the medium
More informationFeed-through terminal blocks for high-current applications
596 PHOENIX CONTACT With the feed-through terminal blocks, you can freely select the connection technology. Choose between traditional screw connection, robust bolt connection, and convenient push-in connection
More informationRedundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
More informationPower Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/2x15DC/1
Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/2x15DC/1 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of
More informationPower Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/24DC/2
Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/24/2 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of operational
More informationVARIOSUB RJ45/IP20 Plug Connectors
VARIOSUB RJ4/IP0 Plug Connectors VARIOSUB-RJ4/IP0 was developed for using RJ4 plug connectors in harsh industrial environments. With it, devices for Industrial Ethernet can also utilize the standard plug
More informationSTEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
More informationDo s and don'ts of connection systems Are there any options when the clearance and creepage distances are not sufficient for UL 1059?
Do s and don'ts of connection systems Are there any options when the clearance and creepage distances are not sufficient for UL 1059? Speaker: Wolfgang Sichmann, Product Manager PCB Plug-In Connectors,
More informationPower consumption In operation At rest For wire sizing. Rated impulse voltage Control pollution degree 3. Non-operating temperature
echnicl dt sheet SRF2A-5(-O) Rotry ctutor with emergency function for utterfly vlves orque orue 2 2 2 m m m ominl voltge AC/DC 2 V Control Control Open-close Oen-close SRF2A-5 SRF2A-5 Deenergised C C SRF2A-5-O
More informationSMD Terminal Blocks with Push-Buttons
SMD Terminal Blocks with Push-Buttons SMD Terminal Blocks Small is Big WAGO s new SMD Terminal Blocks provide push-button termination for conductors 0. 0.75 mm/awg 4 18 (060 Series) and 0.5 1.5 mm/awg
More informationEvolant Solutions Distribution System Series 71
Evolnt Solutions Distriution System Series 71 Contents Introduction One of the leding Suppliers of MDF Products 04 An Excellent Qulity Mngement System 05 Technicl Principles Insultion Displcement Connection
More informationPower consumption In operation At rest For wire sizing. Auxiliary switch
echnicl dt sheet SRF2A-S2-5(-O) Rotry ctutor with emergency function for utterfly vlves orque orue 2 2 2 m m m ominl voltge AC/DC 2 V Control Control Open-close Oen-close wo integrted uxiliry uiliry switches
More informationpicomax The Pluggable Connection System
picomax The Pluggable Connection System TECHNOLOGY THIS SPECIALIZED CAN T MEET ALL REQUIREMENTS. YES IT CAN. CONTENTS picomax Pin spacing: 3. mm/0.138 in;.0 mm/0.197 in; 7. mm/0.29 in Versatile Pluggable
More informationPHOENIX CONTACT - 01/2007
Uninterruptible power supply INTERFACE Data Sheet 103123_00_en PHOENIX CONTACT - 01/2007 Description Especially compact and easy-to-use, the new MINI-DC-UPS/ 24 DC/2 is a combination of the power supply
More informationMCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description
Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V
More informationMessko. Messko. MTraB - Maintenance Free Dehydrating Breather Ordering specifications 686 - XX - XX - XXX - XX
Ordering specifications MTraB -Series Maintenance Free Dehydrating Breather Part no.: 686 - - - - Form your part number by selecting the individual parameters: For example: 686-10--103- Part no.: Parameter
More informationPHOENIX CONTACT - 2012-12-14. Features
Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed
More informationPCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v
Short circuit PCB transformer General Data Rated input 230 Vac Rated output 6-2 x 24 Vac Rated power 0.35-3.2 VA Insulation class B Maximum ambient temperature 70 C Efficiency up to 58 % Degree of protection
More informationVoltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationTECHNICAL DATA TYPE WSL OFF-CIRCUIT TAP CHANGER
TECHNICAL DATA TYPE WSL OFFCIRCUIT TAP CHANGER SHANGHAI HUAMING POWER EQUIPMENT CO., LTD. TYPE WSL OFFCIRCUIT TAP CHANGER TECHNICAL DATA Contents 1. Generl 2 2. Technicl specifictions 2 3. Type designtion
More informationType: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
More informationAP Series Industrial Pushbutton Switch
P Series Features/Benefits IP67 sealed 1,000,000 life cycle Illumination / non-illumination Multiple colored caps Threaded or snap-in mounting Caps available separately RoHS compliant Typical pplications
More informationMaking Wiring Easier Push-in Terminal Blocks for Modular Machine Designs
Making Wiring Easier Push-in Terminal Blocks for Modular Machine Designs By Gordon Busch Product Marketing Industrial Connection Technology Phoenix Contact GmbH & Co. KG Blomberg, Germany Executive Summary
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationBK-W, BKD-W. 1 Technical description
, BKD-W 1 Technicl description Rective power compenstors re designed for compensting rective power (improving power coefficient cos? ) in low voltge networks in industril sites nd division sttions.in the
More informationPLC-RS /21. PLC INTERFACE With PDT Relay, Universal Version. INTERFACE Data Sheet 101780_en_02. 1 Description
PLC INERFCE With PD Relay, niversal Version INERFCE Data Sheet 780_en_02 PHOENIX CONC - 03/08 Description PLC-RS /2 relay modules, which can be used universally, comprise 6.2 mm basic terminal blocks and
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationElectronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
More informationPC 4/ 3-G-7,62. Extract from the online catalog. Order No.: 1804807
Extract from the online catalog PC 4/ 3-G-7,62 Order No.: 1804807 The figure shows a 5-pos. version of the product Header, Nominal current:, Nom. voltage: 400 V, Pitch: 7.62 mm, Number of positions: 3,
More informationPCB TERMINAL BLOCKS. Product Overview
PCB TERMINAL BLOCKS Product Overview AT A GLANCE: THE ENTIRE RANGE Variants: Pin pacing: Terminal blocks, terminal strips (double-, triple-, quadruple-deck terminal strips), disconnect terminal blocks
More informationAF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
More informationBRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009
d BRÖCKSKES BRÖCKSKES D-VIERSEN D-VIERSEN PV1-F PV1-F 4,0 mm 4,0 2 mm VDE-REG.-Nr. 2 C 8292 10/2009 s - THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control
More informationVDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials
VDE Information General Information The voltage which can be applied to a terminal depends on the relevant regulations, the installation conditions and, of course, the dimensions and insulating materials
More informationemobility WAGO Leading the Charge
emobility WAGO Leading the Charge Six Steps to a Full Battery WAGO supports every aspect of charging from: TO-PASS GPRS Modem, VPN Router, 761-520 Identification / Registration /Authorization RFID SMS
More informationBimetallic Overload Relay Specifications
Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationTechnical data. RCBO s DS 261 / DS 271 Residual current operated circuit breakers with integral overcurrent protection
Technical data RCBO s DS 261 / DS 271 Residual current operated circuit breakers with integral overcurrent protection When connecting aluminium conductors ensure that the contact surfaces of the conductors
More informationControl Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
More informationEmergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1
MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More informationThermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
More informationThe range of rail-mounted terminal blocks. for a perfect electrical installation.
The range of rail-mounted terminal blocks for a perfect electrical installation. The range of rail-mounted terminal blocks for a perfect electrical installation. The new standard for rail-mounted terminal
More informationEngineer-to-Engineer Note
Engineer-to-Engineer Note EE-280 Technicl notes on using Anlog Devices DSPs, processors nd development tools Visit our Web resources http://www.nlog.com/ee-notes nd http://www.nlog.com/processors or e-mil
More informationZS10 Screw Clamp Terminal Block
Technical Datasheet 1SNK 161 004 D0201 ZS10 Screw Clamp Terminal Block Feed-through Catalogue Page 1SNK 161 004 S0201 10 mm² 6 AWG 8 mm 0.315 in Spacing Features and Benefits 53 2.09" Save space by connecting
More informationBlock width on rail (mm) Standard block* is shown on blue background
How To Read Terminal Block Specifications How To Read Carton Labels Rated wire size (mm ) Mounting on multiple rail Spacing on rail Spacing 6 mm + 0,05 (.3") M /6 Block width on rail (mm) Standard block*
More informationFuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits
Fuses for Semiconductor Protection - Cylindrical Fuses SIBA cylindrical Ultra-Rapid fuses are available in six different sizes They can be ordered with an integral striker for blown fuse indication or
More informationCONFIGURABLE SAFETY RELAYS
MSI-s/R, MSI-sx/Rx Configurable MSI provide important functions for the efficient flow of automated production processes Special features Combined guarding types by connecting up to 4 AOPDs Additional
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationType: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationSURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More informationZS6-S Screw Clamp Terminal Blocks Disconnect with blade
Technical Datasheet SNK646D00 Catalogue Page SNK646S00 ZS6-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver,
More informationSolenoid Operated Proportional Directional Control Valve (with Pressure Compensation, Multiple Valve Series)
Solenoid Operted Proportionl Directionl Control Vlve (with Pressure Compenstion, Multiple Vlve Series) Hydrulic circuit (Exmple) v Fetures hese stcking type control vlves show pressure compensted type
More informationTemperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
More informationZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket
Technical Datasheet SNK64D00 Catalogue Page SNK64S00 ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket - Ease your test operations with the built-in test sockets, - Screwdriver
More informationTechnicaldata General
Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description
More informationZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket
Technical Datasheet SNK636D00 Catalogue Page SNK636S00 ZS-SF-T Screw Clamp Terminal Blocks For x 0 and x fuses - with test socket - Protect your circuit with x and x0 fuse terminal blocks (fuse not supplied
More informationMultifunctional three-phase monitoring relays CM-MPS CM-MPS.43
Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43 The three-phase monitoring relay CM-MPS.43 monitors the phase parameters phase sequence, phase failure, over- and undervoltage
More informationABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011
Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are
More informationPowermate Range Pitch 7.62
owermate Range itch 7.62 in headers Socket connectors CB connection Solder connection SV 7.62/90 500 V / 43 A SV 7.62/180 500 V / 41 A.2.4 Cable connection Clamping yoke connection Tension clamp connection
More information3-phase, bidirectional energy meter
Data sheet www.sbc-support.com 3-phase, bidirectional energy meter with S0 pulse output Bidirectional energy meter with S0-interface. The S0 interface is a hardware interface for the transmission of measured
More informationThree-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
More information4/3-4/2 Directional valve with solenoid actuation
4/3-4/2 Directionl vlve with solenoid ctution RE 18305-09/12.13 1/10 L511 (LC1-DZ) Size NG6 ISO 4401-03 CETOP RP121 H-03 (CETOP 3) Series 00 Mximum operting pressure 310 r [4500 psi] Mximum flow 50 l/min
More informationZS25 Screw Clamp Terminal Blocks Feed-through
Technical Datasheet SNK668D0 Catalogue Page SNK678S0 ZS Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to mm² AWG in just mm 0.47 in spacing. SNK68V004 SNK004F0000 D CAD
More informationNF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
More informationContact expander modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:
More information2 DIODE CLIPPING and CLAMPING CIRCUITS
2 DIODE CLIPPING nd CLAMPING CIRCUITS 2.1 Ojectives Understnding the operting principle of diode clipping circuit Understnding the operting principle of clmping circuit Understnding the wveform chnge of
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationGeneral Purpose Relays Accessories. Accessories Miniature Relay PT
Miniature Relay PT n Easy replacement of relays on a densely packed DIN rail n No reduction of protection class or creepage/clearance with plastic retainer n Plug-in indicator- and protection modules n
More informationThermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
More informationSMD TERMINAL BLOCKS. Small is Big!
SMD TERMINAL BLOCKS Small is Big! SMD TERMINAL BLOCKS A compact and low-profile PCB connection is required to achieve the most uniform light distribution, while minimizing shadowing. WAGO s surface-mount
More informationContact expansion modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts
More informationMINI MCR-SL-R-UI(-SP)
Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts
More informationBETA Protecting SITOR Semiconductor Fuses
BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008 Product overview Overview Devices Page Field
More informationABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
More informationHARAX circular connector
Show navigation HARAX circular connector Technical characteristics Specifications IEC 60 352-4 IEC 60 9475-2 Approvals HARAX M8-S/M12-S Rated voltage Rated current Diameter of individual strands Conductor
More informationInsta-Lock Gas Vent. Diameter range: 102mm - 152mm (4-6 ) Twin Wall Zalutite / Aluminium Gas Vent System UK PRODUCT CATALOGUE
Inst-Lock Gs Vent Dimeter rnge: 102mm - 152mm (4-6 ) Twin Wll Zlutite / Aluminium Gs Vent System UK PRODUCT CATALOGUE INTRODUCTION Selkirk Inst-Lock is fctory mde twin wll gs vent system comprising rnge
More informationPNOZsigma - Base units
PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable
More informationType: DILM9 10(24VDC) Article No.: 276705
Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More information4/3, 4/2 directional valves solenoid operated
4/3, 4/2 directionl vlves solenoid operted RE 18303-01/07.12 Replces: RE00157/12.07 1/10 Type L5010 (LC04Z) Size 4 Series 00 Mximum operting pressure 310 r [4500 psi] Mximum flow 25 l/m [6.6 gpm] DVI0003
More informationCABLE SPECIFICATION CAN CAB RJ45-SUBD9
CABLE SPECIFICATION All technical information contained in this document is the exclusive property of STI and may neither be used nor disclosed without its prior written consent. AAV 33801 1/8 Connector
More informationwhite paper Ferrules: Your Best Insurance Against Costly Connection Failure Executive Summary
Ferrules: Your Best Insurance Against Costly Connection Failure white paper Executive Summary Thanks to its superior flexibility, longer flex life*, and resistance to vibration, insulated stranded wire
More informationMini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More informationDouble solenoid valve Rp 3/8 - Rp 2 nominal diameters DMV-D/11 DMV-DLE/11
Double solenoid vlve 3/8 - nominl dimeters DMV-D/11 DMV-DLE/11 7.30 Printed in Germny Edition 11.13 Nr. 218 375 1 6 Technicl description The DUNGS double solenoid vlve DMV intertes two solenoid vlves in
More informationIntersection Preassembled 19-inch Rack
Intersection Preassembled 19-inch Rack The intersection preassembled 19-inch rack comes fully assembled, wired and ready to be installed in a server rack. The rack provides communications, power conversion
More informationRM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
More informationHSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
More information