Miniature Circuit-Breaker IEC Series 8562

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Miniature Circuit-Breaker IEC Series 8562"

Transcription

1 > 1 to 3 pole versions > Rated current from A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E > Isolating Function to E > Permanently set thermal and magnetic trips > Power limitation class 3 /5 miniature circuit-breakers meet all technical requirements relating to safe and selective tripping. When short-circuits occur, they restrict the load on the installed circuits due to their excellent current limiting and related high breaking capacity and provide a high level of discrimination for lineside fuses. ATEX / IECEx Zone For use in x x 12503E00 WebCode 8562B Components for System Solutions /1

2 Selection Table MCB 8562 for AC, C-Characteristic Breaking capacity o. of poles Rated operational current Additional options Module width Order number Weight ka mm kg 6 1 pole 1 A without / A without / A without / A without / A without / A without / A without / A without / pole + 1 A without / A without / A Auxiliary / contact 1 changeover 4 A without / A without / A Auxiliary / contact 1 changeover 10 A without / A Fault signal, / changeover 16 A without / pole 2 A without / A without / A without / A without / A without / A without / pole 2 A without / A without / A without / A without / A Auxiliary / contact 1 changeover 16 A without / A without / A without / A without / pole + 10 A without / A without / A without / pole + 16 A without / pole 10 A without / A without / pole 32 A without / pole + 32 A without / other versions and accessories on request /2 Components for System Solutions

3 Selection Table MCB 8562 for AC, B-Characteristic Breaking capacity o. of poles Rated operational current Additional options Module width Order number Weight ka mm kg 6 1 pole 6 A without / pole 10 A without / pole 16 A without / pole + 6 A without / pole + 10 A without / pole + 10 A Auxiliary / contact 1 changeover 6 1 pole + 16 A without / pole + 20 A without / pole 10 A without / pole 16 A without / pole 25 A without / pole 32 A without / pole 16 A without / pole + 6 A without / pole + 10 A without / pole 16 A without / other versions and accessories on request Miniature Circuit-Breaker 1-pole B-Characteristic Module width Width 36 mm Width 54 mm 1/2 8562/ / / E00 Supplement / Breaking cpacity AC 6 ka 8562/ / AC 10 ka 8562/ / AC / DC 6 ka 8562/ UL 10 ka 8562/ / CO / Components for System Solutions /3

4 Miniature Circuit-Breaker 1-pole C-Characteristic Module width Width 36 mm Width 54 mm 1/2 8562/ / / E00 Supplement / AC 6 ka 8562/ / AC 10 ka 8562/ / AC / DC 6 ka 8562/ UL 10 ka 8562/ / UL 135 % 10 ka 8562/ / CO / / / / / / / / / / / Miniature Circuit-Breaker 1-pole D-Characteristic Module width Width 36 mm Width 54 mm 1/2 8562/ / / E00 Supplement / AC 6 ka 8562/ / AC 10 ka 8562/ / UL 10 ka 8562/ / CO / / / / / / / / / / / /4 Components for System Solutions

5 Miniature Circuit-Breaker 1-pole Z-Characteristic Module width Width 36 mm Width 54 mm 1/2 8562/ / / E00 Supplement / AC 10 ka 8562/ / CO / / / / / / / / / / / Miniature Circuit-Breaker 1-pole + B-Characteristic Module width Width 54 mm Width 72 mm 1/2 8562/ / / E00 Supplement / AC 6 ka 8562/ / AC 10 ka 8562/ / UL 10 ka 8562/ / Auxiliary contact without 8562/ CO / Fault signal 1 CO / Components for System Solutions /5

6 Miniature Circuit-Breaker 1-pole + C-Characteristic Module width Width 54 mm Width 72 mm 1/2 8562/ / / E00 Supplement / AC 6 ka 8562/ / AC 10 ka 8562/ / UL 10 ka 8562/ / UL 135 % 10 ka 8562/ / Auxiliary contact without 8562/ CO / Fault signal 1 CO / current A 0,5 8562/ / / / / / / / / / Miniature Circuit-Breaker 1-pole + D-Characteristic Module width 1/2 Width 72 mm 8562/ / E00 Supplement / AC 6 ka 8562/ AC 10 ka 8562/ UL 10 ka 8562/ Auxiliary contact without -- 1 CO 8562/ Fault signal 1 CO 8562/ / / / / / / / / / / / / /6 Components for System Solutions

7 Miniature Circuit-Breaker 2-pole B-Characteristic Module width Width 54 mm Width 72 mm 1/2 3/4 8562/ / /1 4/ E00 Supplement / AC 6 ka 8562/ / AC 10 ka 8562/ / AC / DC 6 ka 8562/ UL 10 ka 8562/ / CO / order spec / current A Miniature Circuit-Breaker 2-pole C-Characteristic Module Width Width 54 mm Width 72 mm 1/2 3/4 8562/ / /1 4/ E00 Supplement / AC 6 ka 8562/ / AC 10 ka 8562/ / AC / DC 6 ka 8562/ UL 10 ka 8562/ / UL 135 % 10 ka 8562/ / CO / order spec / / / / / / / / / / / Components for System Solutions /7

8 Miniature Circuit-Breaker 2-pole D-Characteristic Module Width Width 54 mm Width 72 mm 1/2 3/4 8562/ / /1 4/ E00 Supplement / AC 6 ka 8562/ / AC 10 ka 8562/ / UL 10 ka 8562/ / CO / order spec / / / / / / / / / / / Miniature Circuit-Breaker 2-pole Z-Characteristic Module Width Width 54 mm Width 72 mm 1/2 3/4 8562/ / /1 4/ E00 Supplement / AC 10 ka 8562/ / CO / / / / / / / / / / / /8 Components for System Solutions

9 Miniature Circuit-Breaker 3-pole B-Characteristic Module width Width 72 mm Width 99 mm 1/2 3/4 5/6 8562/ / /1 4/3 6/ E00 Supplement / AC 6 ka 8562/ / AC 10 ka 8562/ / UL 10 ka 8562/ / CO / CO - 1 CO normal and Fault signal 1 CO / Miniature Circuit-Breaker 3-pole C-Characteristic Module width Width 72 mm Width 99 mm 1/2 3/4 5/6 8562/ / /1 4/3 6/ E00 Supplement / Breaking capacit AC 6 ka 8562/ / AC 10 ka 8562/ / UL 10 ka 8562/ / UL 135 % 10 ka 8562/ / CO / CO - 1 CO normal and fault signal 1 CO / / / / / / / / / / / Components for System Solutions /9

10 Miniature Circuit-Breaker 3-pole D-Characteristic Module width Width 72 mm Width 99 mm 1/2 3/4 5/6 8562/ / /1 4/3 6/ E00 Supplement / AC 6 ka 8562/ / AC 10 ka 8562/ / UL 10 ka 8562/ / CO / CO - 1 CO normal and fault signal 1 CO / / / / / / / / / / / Miniature Circuit-Breaker 3-pole + B-Characteristic Module width 1/2 3/4 5/6 Width 99 mm 8562/ /1 4/3 6/ E00 Supplement / AC 10 ka 8562/ UL 10 ka 8562/ Auxiliary contact without 8562/ CO 8562/ Fault signal 1 CO 8562/ CO - 1 CO normal and Fault signal 1 CO 8562/ / / / / / / / /10 Components for System Solutions

11 Miniature Circuit-Breaker 3-pole + C-Characteristic Module width 1/2 3/4 5/6 Width 99 mm 8562/ /1 4/ E00 Supplement / AC 6 ka 8562/ AC 10 ka 8562/ UL 10 ka 8562/ UL 135 % 10 ka 8562/ Auxiliary contact without 8562/ CO 8562/ Fault signal 1 CO 8562/ CO - 1 CO normal and Fault signal 1 CO 8562/ Miniature Circuit-Breaker 3-pole + D-Characteristic Module width 1/2 3/4 2/1 4/3 6/5 5/6 6/ E / / / / / / / / / / / / Width 99 mm 8562/ Supplement / AC 6 ka 8562/ AC 10 ka 8562/ UL 10 ka 8562/ Auxiliary contact without 8562/ CO 8562/ Fault signal 1 CO 8562/ CO - 1 CO normal and Fault signal 1 CO 8562/ / / / / / / / / / / / / Components for System Solutions /11

12 Explosion Protection Marking IECEx Ex d e IIC Ex d e I Europe (ATEX) E II 2 G Ex d e IIC Gb E I M 2 Ex d e I Mb Certificates IECEx IECEx PTB U Europe (ATEX) PTB 02 ATEX 1049 U Other certificates Belarus (Gospromnadzor) Technical Data Device version AC MCBs AC / DC MCBs o. of poles 1 pole, 1 pole +, 2 pole, 3 pole, 3 pole + 1 pole, 2 pole Electrical data AC MCBs AC / DC MCBs voltage Standard version Standard version AC DC AC 1 pole 230 V 48 V 1 pole V pole 230 / 400 V 110 V 1) 3 pole 230 / 400 V pole / 400 V - - 1) 2 poles in series UL- 1 pole 277 V 2) 60 V 2) 1 pole 230 V 3) 60 V 3) 2 pole 277 / 480 V 2) 125 V 2) 2 pole 230 / 400 V 3) 125 V 3) 3 pole 277 / 480 V 2) 125 V 2) 3 pole 230 / 400 V 3) 125 V 3) 2) acc. to UL ) acc. to E DC 1 pole 230 V 220 V 1 pole pole 230 / 400 V 220 V 440 V 1) 1) 2 poles in series Minimal Voltage U bmin 12 V AC / DC 12 V AC / DC Maximal Voltage U bmax AC 250 V / 440 V AC 250 V / 440 V DC 53 V / 120 V DC 250 V / 440 V Rated insulation voltage 500 V 500 V current Tripping characteristic B A Tripping characteristic B Tripping characteristic C/D/Z A Tripping characteristic C/D Rated frequency 50 / 60 Hz 50 / 60 Hz DC Isolation function yes (IEC/E ) yes (IEC/E ) Pulse resistance 6 kv 6 kv Utilization category A (IEC/E ) A (IEC/E ) A 0, A /12 Components for System Solutions

13 Technical Data Electrical data Tripping characteristic curves 08903E E02 Components for System Solutions /13

14 Technical Data Electrical data Tripping characteristic curves Tripping Z-characteristic curve Selectivity class 3 (IEC/E 60898) 6 ka resp. 10 ka Rated switching capacities AC MCBs Poles Series with 6 ka Series with 10 ka Voltage Current Voltage Current (V) (ka) (V) (ka) AC to IEC/E I cn 230 / I cn 230 / AC to IEC/E I cu I cu , I cu I cu I cu I cu DC to IEC/E (Time constante 15 ms) 01546E02 1 I cu / I cs I cu / I cs AC / DC MCBs AC to IEC/E I cn I cn 230 / DC to IEC/E I cu / I cs / Circuit breaker, current limiting with thermal and magnetic release /14 Components for System Solutions

15 Technical Data Characteristics Characteristic to IEC/E Rated current range Loads ormal temperature Thermal overload trip Z B C D A A A A > Semiconductor devices > Elektric heatings > Lighting > Socket outlet circuits > Control circuits e.t.c. > Operating > Operating equipment equipment > Light fitting groups > Motors with > Motors heavy starting > Transformers characteristic e.t.c. e.t.c. 20 C 30 C 30 C 30 C 30 C I n I n I n ,45 I n I n Thermal overload I n -- trip 135% UL Magnetic trip I n I n I n I n Components for System Solutions /15

16 Technical Data Electrical data Response value of short-circuit trip Back-up protection Service life Electrical Mechanical Auxiliary contact Rated working current Ambient Conditions Ambient temperature Correction factors The response value of the short-circuit trip is approximately 40 % higher for DC than for AC at 50 / 60 Hz Fuses must be fitted upstream to protect miniature circuit-breakers against high short-circuit currents in high power networks. These protect the miniature circuit-breakers against short-circuit currents of up to 50 ka. If a short-circuit occurs, both protective devices cut out simultaneously, so that the miniature circuit-breaker is not destroyed and remains fully functional. Following MCBs Type 10 4 switching cycles 2x10 4 switching cycles see circuit diagrams 5 A at 230 V AC 1 A at 60 V DC MCB tripping characteristic Rated operational current I th (A) C, D B, Z B, C, D, Z Preceding fuse type gg Minimal rated operational current (A) 8562/ C In case of different temperature range please consider correction factor! Correction factors for ambient temperatures other than 30 C Maximal rated operational current (A) 10889E E E00 /16 Components for System Solutions

17 Technical Data Mechanical data Degree of protection Degree of protection acc. to IEC/E Connecting terminals IP20 Material Enclosure Epoxy resin Mounting / Installation Terminals Main contacts mm 2 clamp terminals Auxilliary contacts 1.5 mm 2 clamp terminals Schematic 1/2 1/2 1/2 3/4 1/2 3/4 5/6 2/1 2/1 2/1 4/3 2/1 4/3 6/ E E E E00 1 pole 1 pole + 2 pole 3 pole 1/2 3/4 5/ /1 4/3 6/ E E E00 3 pole + Universal current +/-, 1 pole Universal current +/-, 2 pole E E E E00 Auxiliary contact 1 CO Fault indication contact 1 CO Auxiliary contact 1 O Fault indication contact 1 O Auxiliary contact 1 CO Fault indication contact 1 CO U> U< C2 C E00 D1 D E00 Remote trip Undervoltage trip Components for System Solutions /17

18 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations Ø5, ,50 R5, ,50 R5,50 5, ,50 R2, , , E E00 MCB 8562/ MCB 8562/ R5, R5, ,50 5,50 R5,50 R5,50 5, R2, , R2, , E E00 MCB 8562/ MCB 8562/ We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. /18 Components for System Solutions

Ex Miniature Circuit Breaker (MCB) Series 8562

Ex Miniature Circuit Breaker (MCB) Series 8562 Series 85 >, and 3 Pole with Thermal-Magnetic Branch Circuit Protection > Rated current from 0.... 0 > Protection Method: Flameproof for Class Zone; Ex de IIC (US) Ex de IIC (C) and Class I Div Grps, B,

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

Control Switches Series 8008

Control Switches Series 8008 > s Control switch with 2, 3 or 4 pole Load switch 3 pole + 1 auxiliary contact > Up to a maximum of 4 poles > NC contacts with positive opening, suitable for EMERGENCY STOP functions > Latching or spring-return

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

ELFA E90S MINI BREAKERS

ELFA E90S MINI BREAKERS ELFA E90S MINI BREAKERS - ELFA E90S SERIES UL Approved (UL1077) 10KA INTERUPTION CAPACITY OPTIONS FIELD KITS Auxiliary Contacts Alarm Contact Shunt Trip UV Trip Current Limiting Design (Class 3) 3 Different

More information

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404 /, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,

More information

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404 /, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle

More information

8 Installation Equipment

8 Installation Equipment 8 Installation Equipment SolConeX Series 8570, 8571 CES Series 8575, 8579, 8581 10342E00 The plug and sockets Series SolConeX and CES comply with IEC/EN 60 309-1/-2 (CEE) and European standards EN 50 014,

More information

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400 > As pendant light fitting or side entry lamp > Version with 1 or 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened > End of life

More information

Miniature circuit breakers

Miniature circuit breakers Miniature circuit breakers Din-T series ka MCB Standard AS/NZS 898 ) Approval No. N78 Short circuit breaking capacity - 000 Amps Current range 0.5 - Amps,, and pole Sealable and lockable handle Modular

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

Energy Distribution. Applications Low Voltage Systems E8/1. Energy Distribution Panels in Hazardous Areas of Zone 1 and Zone 2

Energy Distribution. Applications Low Voltage Systems E8/1. Energy Distribution Panels in Hazardous Areas of Zone 1 and Zone 2 Energy Distribution Panels in Hazardous Areas of Zone 1 and Zone 2 Circuit breakers up to 800 A Load break switch / Main switch Busbar systems for internal energy distribution Miniature circuit breakers,

More information

Terminal Boxes Series 8146

Terminal Boxes Series 8146 Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

Light Fittings for Fluorescent Lamps Series EXLUX 6001

Light Fittings for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

C60H-DC C curve. Catalogue numbers. Operating voltage V DC V DC

C60H-DC C curve. Catalogue numbers. Operating voltage V DC V DC distriution systems PB104013-34 The supplementary protectors are used in direct current circuits (Industrial control and automations, transport, renewale energy...). They comine the following functions

More information

Control and Distribution Boxes made of Stainless Steel Series 8150

Control and Distribution Boxes made of Stainless Steel Series 8150 www.stahl.de > Circumferential protection channel prevents water entry > Extended temperature range due to high-quality seal s > Optionally with hinges / cam locks or screw-on cover > Hinge versions with

More information

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M The details make the difference MCB S 200/S 200 M A range designed to ensure efficiency and protection

More information

Pendant Light Fitting IEC Series 6470

Pendant Light Fitting IEC Series 6470 > Available light sources highpressure sodium lamps (HSE) metal halide lamps (HIE) mercury lamps (HME) blended lamps (LME) halogen lamps (QT) > Versatile mounting methods > Enclosure made of saltwaterresistant

More information

PHOENIX CONTACT

PHOENIX CONTACT Thermomagnetic circuit breakers CLIPLINE Data sheet 103943_en_04 PHOENIX CONTACT 2010-08-18 1 Description The UT 6-TMC M circuit breaker is a single-position overload circuit breaker with thermomagnetic

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Electronic Circuit Breaker ESS20-0...

Electronic Circuit Breaker ESS20-0... Description Electronic circuit breaker type ESS0-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode power supply. DC 4 V power supplies,

More information

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm Characteristics cam ammeter switch - 3 circuits - 90-12 A - for Ø 22 mm Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product

More information

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm Characteristics cam ammeter switch - 3 circuits - 90-12 A - for Ø 22 mm Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product

More information

Accessories to PR A 28. Shunt trip Vc. Technical data. Dimensional drawing of VC - PR 60. Instructions guide for the mounting of ashunt trip VC-PR 60

Accessories to PR A 28. Shunt trip Vc. Technical data. Dimensional drawing of VC - PR 60. Instructions guide for the mounting of ashunt trip VC-PR 60 Shunt trip Vc accessories to the circuit-breaker RI 60, RI 60J, PRe 60, PRe 40 and modular switches RV 60... utilized for the tripping of circuit-breaker (modular switch) by means of outer source of voltage

More information

Actuator-Sensor-Interface

Actuator-Sensor-Interface Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current

More information

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, Flameproof Enclosure Series 8264. www.stahl. > Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The

More information

K1H014MLH cam ammeter switch - 4 circuits A - screw mounting

K1H014MLH cam ammeter switch - 4 circuits A - screw mounting Characteristics cam ammeter switch - 4 circuits - 90-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing

More information

Circuit Breakers. Next Generation of Protection Capabilities

Circuit Breakers. Next Generation of Protection Capabilities Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many

More information

Control Device System Series ConSig 8040

Control Device System Series ConSig 8040 > Enclosure made of glass fibre reinforced polyester resin > Modular design > 3 sizes available > Individual units can be combined into larger units > Standard and customer-specific versions > With contact

More information

The complete range of consumer switchboards and switchgear

The complete range of consumer switchboards and switchgear Power Distribution The complete range of consumer switchboards and switchgear www.nhp.com.au/mod6 The MOD6 range of consumer switchboards and switchgear is specifically designed for domestic and commercial

More information

60120 Circuit Breaker

60120 Circuit Breaker 6020 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Ordering and Shipping Information Features and Specifications

More information

Application Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole)

Application Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole) Overcurrentswitch,6A,2p,D-Char,AC Partno. FAZ-D6/2 Articleno. 278777 CatalogNo. FAZ-D6/2 Similar to illustration Deliveryprogramme Basic function Miniature circuit breakers Pole 2 pole Tripping characteristic

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

System pro M compact Miniature circuit breaker S 200 S

System pro M compact Miniature circuit breaker S 200 S Data sheet System pro M compact Miniature circuit breaker S 200 S 2CDC021001S0010 2CDC021002S0010 The miniature circuit breaker S 200 S extends the established ABB System pro M compact product range. Thanks

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Series HS6145 For use in Zone 1 and Zone 2 Comply with requirements of Fire Department standard DIN 14 462 Battery state display Deep discharge protection Open circuit monitor Light

More information

5SV Residual Current Protective Devices

5SV Residual Current Protective Devices s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective

More information

Isolating power supplies and output isolators

Isolating power supplies and output isolators Isolating power supplies with HART Overview Analog input isolating power supply, function block diagram Analog input 0/4... 20 ma The isolating power supplies are used for the intrinsically safe operation

More information

UL 489 DIN rail branch circuit breakers

UL 489 DIN rail branch circuit breakers UL 89 DIN rail branch circuit breakers FAZ-NA circuit breakers ACCESSORY TECHNICAL DATA Shunt trip release FAZ-XAA-NA Remote release for subsequent mounting onto FAZ-NA/RT Additional installation of standard

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional

More information

n Choice of equipment SP 58 Index of protection: IP 2X - IP 2XC - under front plate

n Choice of equipment SP 58 Index of protection: IP 2X - IP 2XC - under front plate SP fuse carriers with protected terminals SP fuse carriers with protected terminals www.klinkmann.com n Choice of equipment Maximum cartridge rating Type Rated current 400 V± 0 V± 690 V± gg am gg am gg

More information

Operating Instructions

Operating Instructions Operating Instructions Plug > Contents 1 Contents 1 Contents...2 2 General Information...2 3 Safety instructions...3 4 Conformity to standards...3 5 Function...3 6 Technical Data...4 7 Mounting...6 8 Installation...7

More information

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary

More information

DLA starters General information

DLA starters General information General information The construction of is based on ABB A Line contactors. The mounting plate, including a built-in A contactor, is designed to integrate an ABB manual motor starter type MS325. Starters

More information

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W SCHRACK-INFO Any mains connection If using 4-pole. switches with 3 or 2-poles, ensure connection acc. to assembly instructions

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

Relays SAFETY RELAYS SERIES. High Integrity Safety Relays. Suitable for SIL 3 applications according to IEC and IEC D5000 / D1000 SERIES

Relays SAFETY RELAYS SERIES. High Integrity Safety Relays. Suitable for SIL 3 applications according to IEC and IEC D5000 / D1000 SERIES D5000 / D00 SERIES SAFETY RELAYS SERIES High Integrity Safety Relays Suitable for applications according to IEC 608 and IEC 611 Relays technology for safety DTS0262-1 27 SAFETY RELAY - FEATURES SAFETY

More information

Measuring and monitoring relays CM-MSS (4), CM-MSS (5) Thermistor motor protection relays

Measuring and monitoring relays CM-MSS (4), CM-MSS (5) Thermistor motor protection relays Data sheet Measuring and monitoring relays CM-MSS (4), Thermistor motor protection relays The devices CM-MSS (4) and (5) are used to monitor the overload of motors by the wiring temperature. The motors

More information

MINI-PS AC/24DC/1.3

MINI-PS AC/24DC/1.3 Power supply unit INTERFACE Data sheet 102894_en_02 1 Description PHOENIX CONTACT 2010-12-27 Features MINI POWER is the extremely slim power supply unit with constructional widths of 22.5 mm, 45 mm and

More information

Assembly. Front view. Switch S1. Power Rail

Assembly. Front view. Switch S1. Power Rail Temperature Repeater Features Assembly 1-channel isolated barrier V DC supply (Power Rail) Resistance and RTD input (Pt100, Pt500, Pt1000) Resistance output Accuracy 0.1 % Line fault detection (LFD) for

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

Control Device System Series ConSig 8040

Control Device System Series ConSig 8040 www.stahl.de > Enclosure made of glass fibre reinforced polyester resin > Modular design > 3 sizes available > Individual units can be combined into larger units > Standard and customerspecific versions

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

SINGLE-POLE and MULTI-POLE

SINGLE-POLE and MULTI-POLE SINGLE-POLE and MULTI-POLE Surge Arresters Class II / (C) Connections: 1+1, 3+0, 4+0, 3+1 I max = 20 ka (8/20) MODULAR Housing 33 ISPRO C(R) 40 The ISPRO C(R) 40 series of low cost, over voltage surge

More information

Manual Motor Starter MS 116 up to 16 A Technical Data

Manual Motor Starter MS 116 up to 16 A Technical Data Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

System pro M compact Miniature Circuit Breaker S 200/S 200 M

System pro M compact Miniature Circuit Breaker S 200/S 200 M Data Sheet System pro M compact Miniature Circuit Breaker S 200/S 200 M 2CDC021023S0012 2CDC021038S0012 The miniature circuit breakers of the System pro M compact series S 200 and S 200 M provide state-of-the-art

More information

Motor load monitoring relays

Motor load monitoring relays Motor load CM-E Range Motor load Motor load Fields of application The motor load monitor relay monitors the load states of single-phase and three-phase asynchronous motors. The evaluation of the phase

More information

Circuit-Breakers M4 160 for motor protection. Auxiliary contacts 161 Signalling switch Auxiliary releases

Circuit-Breakers M4 160 for motor protection. Auxiliary contacts 161 Signalling switch Auxiliary releases Circuit Breakers M4 Index Page Circuit-Breakers M4 160 for motor protection Auxiliary contacts 161 Signalling switch Auxiliary releases Insulated 3-pole busbar system 162 Terminal block DIN-rail adapters

More information

BIMETALLIC OVERLOAD RELAYS

BIMETALLIC OVERLOAD RELAYS BULLETIN 193T1 BIMETALLIC OVERLOAD RELAYS SELECTION GUIDE Bulletin 193T1 Overview / Product Selection Bulletin 193T1 Overload protection trip class 10 / 10A Phase loss protection Ambient temperature compensation

More information

Type: DILM9 10(24VDC) Article No.: 276705

Type: DILM9 10(24VDC) Article No.: 276705 Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

LOAD BANK PART NUMBER / OPERATIONS AND MAINTENANCE MANUAL

LOAD BANK PART NUMBER / OPERATIONS AND MAINTENANCE MANUAL LOAD BANK PART NUMBER 2004297/2004298 OPERATIONS AND MAINTENANCE MANUAL Prepared by: 5455 N River RD W Geneva, OH 44041 Phone: 1-800-969-8527 TechSupport@get-psi.com HDT 1 TM-2004297/2004298 TABLE OF CONTENTS

More information

Pendant Light Fittings Series 6050

Pendant Light Fittings Series 6050 > Saltwaterresistant enclosure, aluminium alloy, optionally with painting > Maintenancefree operation and long service life with induction lamp or LED > Mounting with ring bolts or tiltable mounting bracket

More information

How can a charging station for electric vehicles be set up simply and safely?

How can a charging station for electric vehicles be set up simply and safely? SB18 Building > Electromobility > Charging Station Design How can a charging station for electric vehicles be set up simply and safely? Requirement In order to supply electric vehicles with electric power,

More information

Vacuum circuit-breaker - high duty VD4

Vacuum circuit-breaker - high duty VD4 Vacuum circuit-breaker - high duty VD4 ABB Power Technologies / 1-6817 E 17-03-2003 - Vacuum circuit-breaker high duty 12 kv, 1250 2500 A, 40 63 ka 12 kv, 3150/4000 1) A, 63 ka 17.5 kv, 1250 2500 A, 40

More information

Motor Starting Solutions

Motor Starting Solutions Application Guide Motor Starting Solutions Open Type Version In Kit Form Complete ange of Products and Accessories to Create all Motor Starter Types Manual motor starter Short-Circuit Protection... Type

More information

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. Primary-switched power supply with SFB technology, 1 AC, output current 10 A INTERFACE Data Sheet 103128_en_01 PHOENIX CONTACT - 05/2008 1 Description QUINT POWER power supply units highest system availability

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Thermal Circuit Breaker / Switch Series 3131

Thermal Circuit Breaker / Switch Series 3131 Description Combination of single pole circuit breaker and N/FF switch with soft-touch rocker actuation. Contoured rockers are available with a choice of colours and legends, with optional illumination.

More information

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents

More information

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,

More information

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase

More information

Type: EASY512 AC R Article No.: Ordering information Relay outputs Quantity 4 Power supply V DC 115/230 V AC. Description

Type: EASY512 AC R Article No.: Ordering information Relay outputs Quantity 4 Power supply V DC 115/230 V AC. Description Type: EASY512 AC R Article No.: 274103 Ordering information Relay outputs Quantity 4 Power supply V DC 115/230 V AC Description 8 digital inputs 4 relay outputs LCD display Operating buttons Screw terminals

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

ATyS Automatic and remotely operated transfer switches from 125 to 3200 A

ATyS Automatic and remotely operated transfer switches from 125 to 3200 A atys-p_001_b atys_d_001_a_1_cat ATyS p I-0-II 4P ATyS d I-0-II 4P Function The ATyS are three-phase motorised transfer switches with positive break indication. They enable the on load transfer of two three-phase

More information

RM4TR32 three-phase network control relay RM4-T - range V

RM4TR32 three-phase network control relay RM4-T - range V Characteristics three-phase network control relay RM4-T - range 300..430 V Complementary [Us] rated supply voltage Control threshold undervoltage Control threshold overvoltage Output contacts Main Range

More information

ic60n (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi

ic60n (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi Contents Miniature circuit breakers ic0n miniature circuit breakers ka, C curve, -3A ic0h miniature circuit breakers 10kA, C curve, -3A ic0n miniature circuit breakers ka, B curve, -3A ic0h miniature circuit

More information

QF(19) - Series Miniature Circuit Breakers

QF(19) - Series Miniature Circuit Breakers Dual mount 1 pole Dual mount 2 pole Dual mount 3 pole Dual mount 3+N Features AC Circuit Breaker Hydraulic-Magnetic technology % rating capability, independent of ambient temperature One, two, three pole,

More information

QUINT-PS AC/24DC/40

QUINT-PS AC/24DC/40 Extract from the online catalog QUINT-PS-100-240AC/24DC/40 Order No.: 2938879 DIN rail power supply unit 24 V DC/40 A, primary switched-mode, 1- phase. Commercial data EAN 4017918987091 Pack 1 pcs. Customs

More information

Type MS325. Phone: Fax: Web: - Manual motor protectors

Type MS325. Phone: Fax: Web:  -   Manual motor protectors Manual motor protectors Type MS32 MS32-1.0 Manual motor protectors Type MS32 Thermal setting Single-phase 3-phase Catalog List range horsepower ratings 1 horsepower ratings number price (Amps) 120V 240V

More information

QH 10kA Miniature Circuit Breaker & RCBO Range

QH 10kA Miniature Circuit Breaker & RCBO Range NEW QH 10kA Miniature Circuit Breaker & RCBO Range Innovative, Robust, Reliable & Efficient Protection. CONTENTS QH 10kA Miniature Circuit Breaker & RCBO Range 18mm Range QH Miniature Circuit Breakers

More information

AZM /11ZPKE 24 VAC/DC

AZM /11ZPKE 24 VAC/DC Print - Create PDF - Create EXCEL file - Hide system components 21.04.2011-14:12:20h Datasheet - AZM 415-11/11ZPKE 24 VAC/DC Solenoid interlock / AZM 415 Metal enclosure Interlock with protection against

More information

3AH5 Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG 11.05 2010

3AH5 Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG 11.05 2010 Medium-Voltage Equipment Selection and Ordering Data Catalog HG 11.05 2010 Answers for energy. R-HG11-172.tif 2 Siemens HG 11.05 2010 Contents Contents Page 3AH5 Vacuum Circuit-Breakers Medium-Voltage

More information

Easy9. Affordable circuit protection you can depend on

Easy9. Affordable circuit protection you can depend on Affordable circuit protection you can depend on Schneider Electric is a global specialist in energy management. Established as a circuit breaker designer and manufacturer in France since 1920, Schneider

More information

Residual Current Protective Devices

Residual Current Protective Devices Residual Current Protective Devices /2 Introduction / 5SM3 RCCBs /9 SIQUENCE, 5SM3 and 5SU1 universal -sensitive RCCBs, type B and type B+ /12 Additional components /1 5SM2 RC units /18 5SU1 RCBOs /25

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

Plug on Type MCBs & Distribution Boards. Intelligent Choice for Prestigious Buildings

Plug on Type MCBs & Distribution Boards. Intelligent Choice for Prestigious Buildings Plug on Type MCBs & Distribution Boards Intelligent Choice for Prestigious Buildings Table of Contents QO Series Miniature Circuit Breakers Specifications QOvsRCBO Residual Current Circuit Breakers with

More information

SINEAX SI 815 Passive DC Signal Isolator

SINEAX SI 815 Passive DC Signal Isolator with power supply transfer and without separate power supply connection, versions available for FSK 1 and Ex and non-ex, in housing N17 or S17 for rail and wall mounting 0102 II (1) G Application The signal

More information

Control transformers STN..., DTZ Multi-winding transformer UTI

Control transformers STN..., DTZ Multi-winding transformer UTI Control transformers STN..., DTZ Multi-winding transformer UTI Multipurpose power supply units AING All transformers are constructed and tested according to IEC/EN 61558 guidelines. Depending on version,

More information

Technical Data Sheet Positioner Type 824 TD_824. General data

Technical Data Sheet Positioner Type 824 TD_824. General data General data Mounting Enclosure material On linear actuators On quarter-turn actuators ARCA-integrated or acc. to IEC 534-6 (NAMUR) Range of stroke 10... 120 mm ARCA-integrated or acc. to VDI/VDE 3845

More information

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA Miniature Circuit Breaker SU 200 M The next generation MCB for UL/CSA applications within

More information

Zucchini MS - LOW TO MEDiuM POWER busbar

Zucchini MS - LOW TO MEDiuM POWER busbar Zucchini MS - LOW TO MEDiuM POWER busbar The lexibility of the Zucchini MS range during planning and installation makes it ideal for frequently changing requirements in small to medium sized commercial

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information