CATALOGUE CARD WATERTIGHT DOORS
|
|
- Hilary Reeves
- 7 years ago
- Views:
Transcription
1 HYDROSTER Ltd. Phone: (48 58) , fax (48 58) , CATALOGUE CARD WATERTIGHT DOORS 1. Watertight door KKA-57704/10.02 page 1 2. Watertight door KKA-57705/10.02 page 3 3. Watertight door KKA-57706/10.02 page 5 4. Watertight door KKA-57708/10.02 page 7 5. Watertight door KKA-57710/10.02 page 9 6. Watertight door KKA-57711/10.02 page Watertight door KKA-57715/10.02 page Watertight door KKA-57716/10.02 page Watertight door KKA-57717/10.02 page Watertight door KKA-57718/10.02 page Watertight door KKA-57719/10.02 page Watertight door KKA-57720/10.02 page 23
2 Watertight door With electro-hydraulic drive KKA-57704/10.02 Page 1/24 1. DESIGNATION The watertight door is designed for tight closing of communication passages in watertight bulkheads of sea-going cargo ships. A Type of watertight closure WD3 A Type of watertight closure WD3.1 The drawing shows the door closed on right.
3 Page 2/24 KKA-57704/10.02 Watertight door HYDROSTER 2. TECHNICAL CHARACTERISTICS 2.1. The watertight door meets the requirements of Convention SOLAS and requirements of Classification Societies. Rules and receipt of Classification Societies and Institutions should be agreed with the producer The steel welded construction of door. The door is installed by direct welding of door s frame to the watertight bulkhead The horizontal direction of door s slide motion. The direction of closing is determined by looking on the watertight closure from the side of drive unit. The selection of closing direction should be given in an order The admissible load is determined by a customer. The admissible load of door is expressed by maximal pressure of water column loading the door. The height of water column is measured from the lower edge of door s hole to the lower surface of bulkhead deck plating in the plane of ship symmetry Electro-hydraulic drive installed on the closure (door). 3. STRUCTURE OF DENOMINATION OF WATERTIGHT DOOR Type of watertight door WD3, WD3.1 High of door in the light of frame - H Width of door in the light of frame - B Direction of closing P - right, L - left Admissible load of door (kpa) WD3- x - Additional requirements determined in the descriptive way (to be agreed with producer) E. g. : the receipt by Classification Society, supply voltage etc. 2. WAY OF ORDERING In the order there should be given: Name: Watertight door Discriminant: acc. to it. 3 No. of catalogue card: KKA-57704/10.02 The example: Watertight door WD3-2000x800P-60 acc. to KKA-57704/10.02 Manufacturer: HYDROSTER Ltd. ph.: (48 58) fax (48 58) market@hydroster.com.pl
4 Watertight door with electro-hydraulic drive KKA-57705/10.02 Strona 3/24 1. DESIGNATION The watertight door is designed for tight closing of communication passages in watertight bulkheads of sea-going passenger ships. A Type of watertight closure WD4 A Type of watertight closure WD4.1 The drawing shows the closure closed on right.
5 Strona 4/24 KKA-57705/10.02 Watertight door HYDROSTER 2. TECHNICAL CHARACTERISTICS 2.1. The watertight door meets the requirements of Convention SOLAS and requirements of Classification Societies. Rules and receipt of Classification Societies and Institutions should be agreed with the producer The steel welded construction of door. The door is installed by direct welding of door s frame to the watertight bulkhead The horizontal direction of door s slide motion. The direction of closing is determined by looking on the watertight door from the side of drive unit. The selection of closing direction should be given in an order The admissible load is determined by a customer. The admissible load of door is expressed by maximal pressure of water column loading the door. The height of water column is measured from the lower edge of door s hole to the lower surface of bulkhead deck plating in the plane of ship symmetry Electro-hydraulic drive installed on the closure (door). 3. STRUCTURE OF DENOMINATION OF WATERTIGHT CLOSURE Type of watertight door WD4, WD4.1 High of door in the light of frame - H Width of door in the light of frame - B Direction of closing P - right, L - left Admissible load of door (kpa) WD4- x - Additional requirements determined in the descriptive way (to be agreed with producer) E. g. : the receipt by Classification Society, supply voltage etc. 2. WAY OF ORDERING In the order there should be given: Name: Watertight door Discriminant: acc. to it. 3 No. of catalogue card: KKA-57705/10.02 The example: Watertight door WD4-2000x800P-60 acc. to KKA-57705/10.02 Manufacturer: HYDROSTER Ltd. ph.: (48 58) fax (48 58) market@hydroster.com.pl
6 Watertight door with electro-hydraulic drive KKA-57706/10.02 Page 5/24 1. DESIGNATION The watertight door is designed for tight closing of communication passages in watertight bulkheads of sea-going ships. The drawing shows the door closed on right.
7 Page 6/24 KKA-57706/10.02 Watertight door HYDROSTER 2. TECHNICAL CHARACTERISTICS 2.1. The watertight door meets the requirements of Convention SOLAS and requirements of Classification Societies. Rules and receipt of Classification Societies and Institutions should be agreed with the producer The steel welded construction of door. The door is installed by direct welding of door s frame to the watertight bulkhead The horizontal direction of door s slide motion. The direction of closing is determined by looking on the watertight door from the side of drive unit. The selection of closing direction should be given in an order The admissible load is determined by a customer. The admissible load of door is expressed by maximal pressure of water column loading the door. The height of water column is measured from the lower edge of door s hole to the lower surface of bulkhead deck plating in the plane of ship symmetry The device consists of watertight door with individual hydraulic drive mounted by Shipyard near the door. The hydraulic drive can be executed for cargo or passenger ships or other solutions (e.g. manual drive). 3. STRUCTURE OF DENOMINATION OF WATERTIGHT DOOR Type of watertight door High of door in the light of frame - H Width of door in the light of frame - B Direction of closing P - right, L - left Admissible load of door (kpa) WD6- x - Additional requirements determined in the descriptive way (to be agreed with producer) E. g. : the receipt by Classification Society, supply voltage etc. 2. WAY OF ORDERING In the order there should be given: Name: Watertight door Discriminant: acc. to it. 3 No. of catalogue card: KKA-57706/10.02 The example: Watertight door WD6-2000x800P-60 acc. to KKA-57706/10.02 Manufacturer: HYDROSTER Ltd. ph.: (48 58) fax (48 58) market@hydroster.com.pl
8 Watertight door With electro-hydraulic drive Low sill door KKA-57708/10.02 Page 7/24 1. DESIGNATION The watertight door with low sill is designed for tight closing of communication passages in watertight bulkheads of sea-going cargo ships. The drawing shows the door closed on right. Low sill door used with concrete used with ramp
9 Page 8/24 KKA-57708/10.02 Watertight door HYDROSTER 2. TECHNICAL CHARACTERISTICS 2.1. The watertight door meets the requirements of Convention SOLAS and requirements of Classification Societies. Rules and receipt of Classification Societies and Institutions should be agreed with the producer The steel welded construction of door. The door is installed by direct welding of door s frame to the watertight bulkhead The horizontal direction of door s slide motion. The direction of closing is determined by looking on the watertight door from the side of drive unit. The selection of closing direction should be given in an order The admissible load is determined by a customer. The admissible load of door is expressed by maximal pressure of water column loading the door. The height of water column is measured from the lower edge of door s hole to the lower surface of bulkhead deck plating in the plane of ship symmetry Electro-hydraulic drive installed on the door. 3. STRUCTURE OF DENOMINATION OF WATERTIGHT DOOR Type of watertight door High of door in the light of frame - H Width of door in the light of frame - B Direction of closing P - right, L - left Admissible load of door (kpa) WD1.0- x - Additional requirements determined in the descriptive way (to be agreed with producer) E. g. : the receipt by Classification Society, supply voltage etc. 2. WAY OF ORDERING In the order there should be given: Name: Watertight door Discriminant: acc. to it. 3 No. of catalogue card: KKA-57708/10.02 The example: Watertight door WD x800P-60 acc. to KKA-57708/10.02 Manufacturer: HYDROSTER Ltd. ph.: (48 58) fax (48 58) market@hydroster.com.pl
10 Watertight door With electro-hydraulic drive Low sill door KKA-57710/10.02 Page 9/24 1. DESIGNATION The watertight door with low sill is designed for tight closing of communication passages in watertight bulkheads of sea-going passenger ships. The drawing shows the door closed on right. Low sill door used with concrete used with ramp
11 Page 10/24 KKA-57710/10.02 Watertight door HYDROSTER 2. TECHNICAL CHARACTERISTICS 2.1. The watertight door meets the requirements of Convention SOLAS and requirements of Classification Societies. Rules and receipt of Classification Societies and Institutions should be agreed with the producer The steel welded construction of door. The door is installed by direct welding of door s frame to the watertight bulkhead The horizontal direction of door s slide motion. The direction of closing is determined by looking on the watertight door from the side of drive unit. The selection of closing direction should be given in an order The admissible load is determined by a customer. The admissible load of door is expressed by maximal pressure of water column loading the door. The height of water column is measured from the lower edge of door s hole to the lower surface of bulkhead deck plating in the plane of ship symmetry Electro-hydraulic drive installed on the door. 3. STRUCTURE OF DENOMINATION OF WATERTIGHT DOOR Type of watertight door High of door in the light of frame - H Width of door in the light of frame - B Direction of closing P - right, L - left Admissible load of door (kpa) WD2- x - Additional requirements determined in the descriptive way (to be agreed with producer) E. g. : the receipt by Classification Society, supply voltage etc. 2. WAY OF ORDERING In the order there should be given: Name: Watertight door Discriminant: acc. to it. 3 No. of catalogue card: KKA-57710/10.02 The example: Watertight door WD2-2000x800P-60 acc. to KKA-57710/10.02 Manufacturer: HYDROSTER Ltd. ph.: (48 58) fax (48 58) market@hydroster.com.pl
12 Watertight door With electro-hydraulic drive Low sill door KKA-57711/10.02 Page 11/24 1. DESIGNATION The watertight door with low sill is designed for tight closing of communication passages in watertight bulkheads of sea-going passenger ships. The drawing shows the closure closed on right. Low sill door used with concrete used with ramp
13 Page 12/24 KKA-57711/10.02 Watertight door HYDROSTER 2. TECHNICAL CHARACTERISTICS 2.1. The watertight door meets the requirements of Convention SOLAS and requirements of Classification Societies. Rules and receipt of Classification Societies and Institutions should be agreed with the producer The steel welded construction of door. The door is installed by direct welding of door s frame to the watertight bulkhead The horizontal direction of door s slide motion. The direction of closing is determined by looking on the watertight door from the side of drive unit. The selection of closing direction should be given in an order The admissible load is determined by a customer. The admissible load of door is expressed by maximal pressure of water column loading the door. The height of water column is measured from the lower edge of door s hole to the lower surface of bulkhead deck plating in the plane of ship symmetry Electro-hydraulic drive installed on the door. 3. STRUCTURE OF DENOMINATION OF WATERTIGHT CLOSURE Type of watertight door High of door in the light of frame - H Width of door in the light of frame - B Direction of closing P - right, L - left Admissible load of door (kpa) WD3- x - Additional requirements determined in the descriptive way (to be agreed with producer) E. g. : the receipt by Classification Society, supply voltage etc. 2. WAY OF ORDERING In the order there should be given: Name: Watertight door Discriminant: acc. to it. 3 No. of catalogue card: KKA-57711/10.02 The example: Watertight door WD3-2000x800P-60 acc. to KKA-57711/10.02 Manufacturer: HYDROSTER Ltd. ph.: (48 58) fax (48 58) market@hydroster.com.pl
14 Watertight door with electric drive Low sill door KKA-57715/10.01 Page 13/24 1. DESIGNATION The watertight door with low sill is designed for tight closing of communication passages in watertight bulkheads of sea-going passenger ships and yachts. The drawing shows the door closed on right. Low sill door used with concrete used with ramp
15 page 14/24 KKA-57715/10.01 Watertight door HYDROSTER 2. TECHNICAL CHARACTERISTICS 2.1. The watertight door meets the requirements of Convention SOLAS and requirements of Classification Societies. Rules and receipt of Classification Societies and Institutions should be agreed with the producer The steel welded construction of door. The door is installed by direct welding of door s frame to the watertight bulkhead The horizontal direction of door s slide motion. The direction of closing is determined by looking on the watertight door from the side of slide. The selection of closing direction should be given in an order The admissible load is determined by a customer. The admissible load of door is expressed by maximal pressure of water column loading the door. The height of water column is measured from the lower edge of door s hole to the lower surface of bulkhead deck plating in the plane of ship symmetry. 3. STRUCTURE OF DENOMINATION OF WATERTIGHT DOOR Type of watertight door High of door in the light of frame - H Width of door in the light of frame - B Direction of closing: P - right, L - left Admissible load of door (kpa) WDE1- x - Additional requirements determined in the descriptive way (to be agreed with producer) E. g. : the receipt by Classification Society, supply voltage etc. 4. WAY OF ORDERING In the order there should be given: Name: Watertight door Discriminant: acc. to it. 3 No. of catalogue card: KKA-57715/10.01 The example: Watertight door WDE1-2000x800P-60 acc. to KKA-57715/10.01 Manufacturer: HYDROSTER Ltd. ph.: (48 58) fax (48 58) market@hydroster.com.pl
16 Watertight door with electric drive KKA-57716/10.01 Page 15/24 1. DESIGNATION The watertight door with low sill is designed for tight closing of communication passages in watertight bulkheads of sea-going passenger ships and yachts. The drawing shows the door closed on right.
17 page 16/24 KKA-57716/10.01 Watertight door HYDROSTER 2. TECHNICAL CHARACTERISTICS 2.1. The watertight door meets the requirements of Convention SOLAS and requirements of Classification Societies. Rules and receipt of Classification Societies and Institutions should be agreed with the producer The steel welded construction of door. The door is installed by direct welding of door s frame to the watertight bulkhead The horizontal direction of door s slide motion. The direction of closing is determined by looking on the watertight closure from the side of slide. The selection of closing direction should be given in an order The admissible load is determined by a customer. The admissible load of door is expressed by maximal pressure of water column loading the door. The height of water column is measured from the lower edge of door s hole to the lower surface of bulkhead deck plating in the plane of ship symmetry. 3. STRUCTURE OF DENOMINATION OF WATERTIGHT DOOR Type of watertight door: WDE2, WDE2.1 High of door in the light of frame - H Width of door in the light of frame - B Direction of closing: P - right, L - left Admissible load of door (kpa) WDE2- x - Additional requirements determined in the descriptive way (to be agreed with producer) E. g. : the receipt by Classification Society, supply voltage etc. 4. WAY OF ORDERING In the order there should be given: Name: Watertight door Discriminant: acc. to it. 3 No. of catalogue card: KKA-57716/10.01 The example: Watertight door WDE2-2000x800P-60 acc. to KKA-57716/10.01 WDE x800P-60 acc. to KKA-57716/10.01 Manufacturer: HYDROSTER Ltd. ph.: (48 58) fax (48 58) market@hydroster.com.pl
18 Watertight door with electric drive Low sill door with slim control panel KKA-57717/10.01 Page 17/24 1. DESIGNATION The watertight door with low sill is designed for tight closing of communication passages in watertight bulkheads of sea-going passenger ships and yachts. The drawing shows the door closed on right. Low sill door used with concrete used with ramp
19 page 18/24 KKA-57717/10.01 Watertight door HYDROSTER 2. TECHNICAL CHARACTERISTICS 2.1. The watertight door meets the requirements of Convention SOLAS and requirements of Classification Societies. Rules and receipt of Classification Societies and Institutions should be agreed with the producer The steel welded construction of door. The door is installed by direct welding of door s frame to the watertight bulkhead The horizontal direction of door s slide motion. The direction of closing is determined by looking on the watertight closure from the side of slide. The selection of closing direction should be given in an order The admissible load is determined by a customer. The admissible load of door is expressed by maximal pressure of water column loading the door. The height of water column is measured from the lower edge of door s hole to the lower surface of bulkhead deck plating in the plane of ship symmetry. 3. STRUCTURE OF DENOMINATION OF WATERTIGHT DOOR Type of watertight door High of door in the light of frame - H Width of door in the light of frame - B Direction of closing: P - right, L - left Admissible load of door (kpa) WDE3- x - Additional requirements determined in the descriptive way (to be agreed with producer) E. g. : the receipt by Classification Society, supply voltage etc. 4. WAY OF ORDERING In the order there should be given: Name: Watertight door Discriminant: acc. to it. 3 No. of catalogue card: KKA-57717/10.01 The example: Watertight door WDE3-2000x800P-60 acc. to KKA-57717/10.01 Manufacturer: HYDROSTER Ltd. ph.: (48 58) fax (48 58) market@hydroster.com.pl
20 Watertight door with electric drive Slim control panel KKA-57718/10.01 Page 19/24 1. DESIGNATION The watertight door with low sill is designed for tight closing of communication passages in watertight bulkheads of sea-going passenger ships and yachts. The drawing shows the door closed on right.
21 page 20/24 KKA-57718/10.01 Watertight door HYDROSTER 2. TECHNICAL CHARACTERISTICS 2.1. The watertight door meets the requirements of Convention SOLAS and requirements of Classification Societies. Rules and receipt of Classification Societies and Institutions should be agreed with the producer The steel welded construction of door. The door is installed by direct welding of door s frame to the watertight bulkhead The horizontal direction of door s slide motion. The direction of closing is determined by looking on the watertight closure from the side of slide. The selection of closing direction should be given in an order The admissible load is determined by a customer. The admissible load of door is expressed by maximal pressure of water column loading the door. The height of water column is measured from the lower edge of door s hole to the lower surface of bulkhead deck plating in the plane of ship symmetry. 3. STRUCTURE OF DENOMINATION OF WATERTIGHT DOOR Type of watertight door: WDE4, WDE4.1 High of door in the light of frame - H Width of door in the light of frame - B Direction of closing: P - right, L - left Admissible load of door (kpa) WDE4- x - Additional requirements determined in the descriptive way (to be agreed with producer) E. g. : the receipt by Classification Society, supply voltage etc. 4. WAY OF ORDERING In the order there should be given: Name: Watertight door Discriminant: acc. to it. 3 No. of catalogue card: KKA-57718/10.01 The example: Watertight door WDE4-2000x800P-60 acc. to KKA-57718/10.01 WDE x800P-60 acc. to KKA-57718/10.01 Manufacturer: HYDROSTER Ltd. ph.: (48 58) fax (48 58) market@hydroster.com.pl
22 Watertight door with electric drive Low sill door without control panel KKA-57719/10.01 Page 21/24 1. DESIGNATION The watertight door with low sill is designed for tight closing of communication passages in watertight bulkheads of sea-going passenger ships and yachts. Elements of panel to be fitted separately at yard s/owner convenience. The drawing shows the door closed on right. Low sill door used with concrete used with ramp
23 page 22/24 KKA-57719/10.01 Watertight door HYDROSTER 2. TECHNICAL CHARACTERISTICS 2.1. The watertight door meets the requirements of Convention SOLAS and requirements of Classification Societies. Rules and receipt of Classification Societies and Institutions should be agreed with the producer The steel welded construction of door. The door is installed by direct welding of door s frame to the watertight bulkhead The horizontal direction of door s slide motion. The direction of closing is determined by looking on the watertight closure from the side of slide. The selection of closing direction should be given in an order The admissible load is determined by a customer. The admissible load of door is expressed by maximal pressure of water column loading the door. The height of water column is measured from the lower edge of door s hole to the lower surface of bulkhead deck plating in the plane of ship symmetry. 3. STRUCTURE OF DENOMINATION OF WATERTIGHT DOOR Type of watertight door High of door in the light of frame - H Width of door in the light of frame - B Direction of closing: P - right, L - left Admissible load of door (kpa) WDE5- x - Additional requirements determined in the descriptive way (to be agreed with producer) E. g. : the receipt by Classification Society, supply voltage etc. 4. WAY OF ORDERING In the order there should be given: Name: Watertight door Discriminant: acc. to it. 3 No. of catalogue card: KKA-57719/10.01 The example: Watertight door WDE5-2000x800P-60 acc. to KKA-57719/10.01 Manufacturer: HYDROSTER Ltd. ph.: (48 58) fax (48 58) market@hydroster.com.pl
24 Watertight door with electric drive Without control panel KKA-57720/10.01 Page 23/24 1. DESIGNATION The watertight door with low sill is designed for tight closing of communication passages in watertight bulkheads of sea-going passenger ships and yachts. Elements of panel to be fitted separately at yard s/owner convenience. The drawing shows the door closed on right.
25 page 24/24 KKA-57720/10.01 Watertight door HYDROSTER 2. TECHNICAL CHARACTERISTICS 2.1. The watertight door meets the requirements of Convention SOLAS and requirements of Classification Societies. Rules and receipt of Classification Societies and Institutions should be agreed with the producer The steel welded construction of door. The door is installed by direct welding of door s frame to the watertight bulkhead The horizontal direction of door s slide motion. The direction of closing is determined by looking on the watertight closure from the side of slide. The selection of closing direction should be given in an order The admissible load is determined by a customer. The admissible load of door is expressed by maximal pressure of water column loading the door. The height of water column is measured from the lower edge of door s hole to the lower surface of bulkhead deck plating in the plane of ship symmetry. 3. STRUCTURE OF DENOMINATION OF WATERTIGHT DOOR Type of watertight door High of door in the light of frame - H Width of door in the light of frame - B Direction of closing: P - right, L - left Admissible load of door (kpa) WDE6- x - Additional requirements determined in the descriptive way (to be agreed with producer) E. g. : the receipt by Classification Society, supply voltage etc. 4. WAY OF ORDERING In the order there should be given: Name: Watertight door Discriminant: acc. to it. 3 No. of catalogue card: KKA-57720/10.01 The example: Watertight door WDE6-2000x800P-60 acc. to KKA-57720/10.01 Manufacturer: HYDROSTER Ltd. ph.: (48 58) fax (48 58) market@hydroster.com.pl
Access in motion. Watertight Bulkhead Doors. Ventilation Duct Closing Systems. Hydraulic Marine Systems For Special Applications.
Access in motion Watertight Bulkhead Doors Ventilation Duct Closing Systems Hydraulic Marine Systems For Special Applications Shell Doors Watertight Building Doors SCHOENROCK with History Our Business
More informationINTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP
INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES Interpretations of the FTP CONTENTS FTP1 Adhesives used in A or B class divisions (FTP Code 3.1, Res A.754 para. 3.2.3) June 2000 FTP2 Pipe and duct
More informationVLCC Structural Design - Past, Present and Future
TSCF 2007 Shipbuilders Meeting VLCC Structural Design - Past, Present and Future Seong Ki Kim 1), Minsu Cho 2), Theodore W. Kang 3) Sungkon Han 4) and ManSoo Kim 5) 1) Hull Basic Design Team, DSME, Seoul,
More information19 DYNAmax Free Standing Server C A B I N E T s
9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide
More information19 DYNAmax Free Standing Server C A B I N E T s
9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=600mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide
More informationAluminium systems profile selection
Aluminium systems profile selection The purpose of this document is to summarise the way that aluminium profile selection should be made, based on the strength requirements for each application. Curtain
More informationWINDOW AND DOOR REPLACEMENT REQUIREMENTS
WINDOW AND DOOR REPLACEMENT REQUIREMENTS Should you have any questions after reading the following information, please call the Building Inspection Department at 651-439-4439 to discuss the topics of concern.
More informationLow Voltage Switchboards The Best Technical Solution for Your Ship
The Best Technical Solution for Your Ship Wärtsilä SAM Electronics Optimal Power Distribution The uninterrupted supply of power to systems and consumers onboard modern ships is an extremly important matter.
More informationI N T E R N A T I O N A L R E S I D E N T I A L CO D E
Visual Interpretation Of The I N T E R N A T I O N A L R E S I D E N T I A L CO D E 2006 STAIR BUILDING CODE Portions of this document reproduce sections from the 2006 International Residential Code, International
More informationResidential Decks. Planning and Development Services Department
Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: permitservices@opkansas.org Planning and Development Services Department Residential Decks
More informationPurchasing Services AOC 200 4202 East Fowler Avenue Tampa, Florida 33620 (813) 974-2481. Web Address: http://www.usf.edu/business-finance/purchasing/
Purchasing Services AOC 200 4202 East Fowler Avenue Tampa, Florida 33620 (813) 974-2481 Web Address: http://www.usf.edu/business-finance/purchasing/ January 20, 2016 Invitation to Negotiate No. Entitled:
More informationARIE KEPETS - SR. VICE PRESIDENT MARCH 09
YOUR ONE STOP SOURCE FOR ALL YOUR CONTAINMENT NEEDS ARIE KEPETS - SR. VICE PRESIDENT MARCH 09 VR CONTAINMENT LLC INC. 176-25 UNION TURNPIKE SUITE 175 FRESH MEADOWS NY 11366 TEL 516 673 4961 FAX 866 286
More informationSSG PRODUCTS FOR SHIPS AND OFFSHORE
6.1 SSG PRODUCTS FOR SHIPS AND OFFSHORE SSG workshop cabinets, tables and shelving system specially adapted to be used on-board ships and offshore. Developed in close cooperation with users from these
More informationThe replacement or modification of existing windows shall comply with the following requirements:
City of La Habra Heights Building Division 1245 N. Hacienda Road La Habra Heights, CA 90631 Office: (562) 694-6302 ext. 228 Fax: (562) 690-5010 WINDOW REPLACEMENT 2010 CALIFORNIA RESIDENTIAL CODE (CRC)
More informationPart 0 - Classification and Surveys Classification and Surveys I-0 2016-01
Code Edition I - Ship Technology Part 0 - Classification and Surveys Classification and Surveys I-0 2016-01 Part 1 - Seagoing Ships Chapter 1 - Hull Structures I-1-1 2016-01 Chapter 1 - Hull Structures
More informationSPECIAL VEHICLES TERBERG RT-SERIES HANDLING HEAVY CARGO WITH TOTAL CONFIDENCE
SPECIAL VEHICLES TERBERG RT-SERIES HANDLING HEAVY CARGO WITH TOTAL CONFIDENCE BASED ON PROVEN DESIGNS Gross Combination Weights up to 375 tonnes Fifth wheel lifting capacity up to 45 tonnes Ergoturn 180
More informationRules for Classification and Construction Additional Rules and Guidelines
VI Rules for Classification and Construction Additional Rules and Guidelines 7 Guidelines for the Performance of Type Approvals 4 Test Requirements for Sealing Systems of Bulkhead and Deck Penetrations
More informationRule-Based Ship Design
Rule-Based Ship Design A White Paper Process, Power & Marine, a division of Intergraph Table of Contents 1. Introduction... 1 2. Advantages to Rule-Based Design... 2 2.1 Embedding Design Practices...2
More informationAir-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association
Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-
More informationLinear Motion & Assembly Technologies - Guarding System
Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Linear Motion & Assembly Technologies - Guarding System EcoSafe Guarding System from Rexroth Guarding
More informationTABLE OF CONTENTS. INTRODUCTION... 5 Advance Concrete... 5 Where to find information?... 6 INSTALLATION... 7 STARTING ADVANCE CONCRETE...
Starting Guide TABLE OF CONTENTS INTRODUCTION... 5 Advance Concrete... 5 Where to find information?... 6 INSTALLATION... 7 STARTING ADVANCE CONCRETE... 7 ADVANCE CONCRETE USER INTERFACE... 7 Other important
More informationLeaflet for damage stability calculation according to SOLAS 2009
Hamburg 2008-07-23 Version 1.2 Leaflet for damage stability calculation according to SOLAS 2009 Table of contents: 1 Background... 2 2 Intention of this paper...2 3 Formal application... 2 3.1 Application
More informationSERVER ROOM CABINET INSTALLATION CONCEPTS
SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS ZPAS 169 EXAMPLES OF SERVER ROOMS PROJECTS WITH ZPAS CABINETS Data Box in the
More informationCLASSIFICATION NOTES
CLASSIFICATION NOTES Type Approval, Installation and Testing of Water Level Detectors on Bulk Carriers and Single Hold Cargo Ships other than Bulk Carriers General Information This edition of the classification
More informationSteel Door Frame Installation in Steel Stud Construction
Steel Door Frame Installation in Steel Stud Construction For use with the Steel Door Institute (SDI) video How to Install a Steel Door Frames in Steel Stud Construction This manual gives you step-by-step
More informationA U T O M O T I V E L I F T S
Q U A L I T Y Y O U E X P E C T AT A P R I C E Y O U W O U L D N T T H E S TA N D A R D I N I N F O R M AT I O N, E Q U I P M E N T A N D D I A G N O S T I C S S Y S T E M S h t t p : / / d i a g n o s
More informationGK Packing System Welding Instructions
GK Packing System Welding Instructions Roxtec GmbH Neuer Höltigbaum 1-3, 22143 Hamburg GERMANY Tel +49 (040) 657398-0, Fax +49 (040) 657398-50 EMAIL info@de.roxtec.com, www.roxtec.de Welding instructions
More informationPackaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
More informationFSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS
3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 INSTALLATION INSTRUCTIONS FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS 11/2 HOUR UL555 RATED UL555S LEAKAGE RATED
More informationGUIDELINES FOR FLOODING DETECTION SYSTEMS ON PASSENGER SHIPS
INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: 020 7735 7611 Fax: 020 7587 3210 IMO E Ref. T1/2.04 MSC.1/Circ.1291 9 December 2008 GUIDELINES FOR FLOODING DETECTION SYSTEMS
More informationCorrosion protection of crude oil cargo tanks new IMO regulations
Guidance note oil cargo tanks new IMO regulations Guidance for shipowners and operators, manufacturers and ship builders 1. Background to the new requirements Following incidents resulting from structural
More informationProcurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier
Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier A. Requirement This document is to be used to specify the physical and operational
More information27th session 20 December 2011. Resolution A.1045(27) Adopted on 30 November 2011 (Agenda item 9) PILOT TRANSFER ARRANGEMENTS
E ASSEMBLY A 27/Res.1045 27th session 20 December 2011 Agenda item 9 Original: ENGLISH Resolution A.1045(27) Adopted on 30 November 2011 (Agenda item 9) PILOT TRANSFER ARRANGEMENTS THE ASSEMBLY, RECALLING
More informationLight-Weight Panels. High quality panels. www.stenca.com
Light-Weight Panels High quality panels WELCOME TO STENCA TRADING - Global focus with local service Stenca Trading offers optimal solutions for the offshore, marine, refineries and cogeneration industry.
More informationBLADE S-MAX Cabinet for Blade Server
Cabinet for Blade Server 1 2 Overview Material specification Corner verticals: 1.5 mm steel End frames: 1.5 mm steel Panel mounts: 2.0 mm steel Panel mount supports: 1.5 mm steel Side panels, door and
More informationRear Impact Guard TEST METHOD 223. Standards and Regulations Division. Issued: December 2003
Transport Canada Safety and Security Road Safety Transports Canada Sécurité et sûreté Sécurité routière Standards and Regulations Division TEST METHOD 223 Rear Impact Guard Issued: December 2003 Standards
More informationDamage Reporting Procedures
Damage Reporting Procedures Criteria. The criteria for reporting damaged product is: six (6) plies or more of tear damage, wet or water damage rolls and rolls that have crush or core damage. If product
More informationEnvelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit
R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed
More informationglass & Glazing Products
glass & Glazing Products WallMaker Create an unlimited variety of bright, beautiful and secure interior environments with the easy-to-install Stylmark WallMaker glass wall system. This versatile system
More information18. SKATES, PLATFORM HAND TRUCKS, LIFTING TABLES AND HAND TROLLEYS
18. SKATES, PLATFORM HAND TRUCKS, LIFTING TABLES AND HAND TROLLEYS SKATES LIFTING TABLES HAND TROLLEYS PLATFORM HAND TRUCKS SKATES SKATE 1500KG for moving machines and equipment duration oiled metal wheels
More informationBARRIER LIFT SYSTEM 2 BARRIER LIFT SYSTEM
BARRIER LIFT SYSTEM BARRIER LIFT SYSTEM The crash rated elkosta Barrier Lift System BLS offers maximum security for highly sensitive entry or exit points against unauthorised vehicles attempting to break
More informationREQUIREMENT 3. Usable Doors
Chapter Three: REQUIREMENT 3 Usable Doors 3...covered multifamily dwellings with a building entrance on an accessible route shall be designed in such a manner that all the doors designed to allow passage
More informationfoot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.
Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12
More informationT&B Cable Tray. Metallic Aluminum. Straight Lengths. Tray Bottom Types Ladder, Ventilated and Solid Trough
Tray Bottom Types Ladder Extra wide aluminum rungs are welded to extruded aluminum I-beam siderails. Every second rung is reversed to allow for easy top or bottom mounting of cable ties and clamps. All
More informationWe ll help you determine your containment needs
We ll help you determine your containment needs Ask yourself the five questions below for help choosing the right containment products to keep your workplace clean, safe and compliant! For more assistance,
More informationGuidance Note on the Need for Planning Permission for the Development of Existing Houses and Flats (effective from 6 February 2012)
de Guidance Note on the Need for Planning Permission for the Development of Existing Houses and Flats (effective from 6 February 2012) Introduction The rules governing permitted development (that is, whether
More informationPRODUCT AND ENGINEERING MANUAL
TABLE OF CONTENTS Table of Contents... 1 General Mezzanine Information and Specifications... 2 SM0010PE Mezzanine Plan Information... 3 Information Required for Mezzanine Structures... 4 Floor And/Or Mezzanine
More informationLOADING DOCK EQUIPMENT. A. Section 03100 - Concrete Forms and Accessories: Placement of anchors into concrete.
LOADING DOCK EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Loading dock equipment of the following types: 1. Dock lifts. 2. Control stations. 1.2 RELATED SECTIONS A. Section 03100 - Concrete Forms and
More informationSecurity Matrix. STCW Regulation (applicable from 1 st of January 2014):
Security Matrix Seafarers holding SSO (A VI/5) certificate are not required to obtain Designated Security Duties (A VI/6 2) and Security Awareness (A VI/6 1) certificates Seafarers holding Designated Security
More informationDE Frame with C Series Sidelight
TOOLS REQUIRED Tape measure 6' magnetic level 3' magnetic level Screw gun with clutch adjusted #2 phillips tip #3 phillips tip Screwdriver (used to adjust frame on will using oval slots) Pry Bar Powder
More informationGUIDELINES FOR THE DRAINAGE OF FIRE-FIGHTING WATER FROM CLOSED VEHICLE AND RO-RO SPACES AND SPECIAL CATEGORY SPACES OF PASSENGER AND CARGO SHIPS
INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: 020 7735 7611 Fax: 020 7587 3210 IMO E Ref. T4/4.01 MSC.1/Circ.1320 11 June 2009 GUIDELINES FOR THE DRAINAGE OF FIRE-FIGHTING
More informationHinge, Blocker, and Tab Adjustment Guide
Hinge, Blocker, and Guide for Andersen A-Series Hinged Outswing; 400 Series Frenchwood Hinged Outswing Patio Doors and 400 Series Frenchwood Hinged Outswing Patio Doors with Stormwatch Protection Hinge,
More information2015 PRICES. Interior. WITH AZEK Harvest Bronze, Silver Oak, or Hazelwood
STANDARD SECTIONS WITH DECKING Legs are included up to 8ft long. Standard footpads measure 4 x 14 2015 PRICES WITH CEDAR Western Red (color varies) WITH AZEK Brownstone or Slate Gray WITH AZEK Harvest
More informationINSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nailing fin. While the use of these installation instructions
More informationM/ Y VARIETY VOYAGER. Ship specifications
M/ Y VARIETY VOYAGER Ship specifications YOUR SHIP: THE MOTORYACHT VARIETY VOYAGER The new build 68 m / 223 ft state of the art Mega Yacht will accommodate just 72 passengers in 36 cabins. Built under
More informationSUPER SHED. Indoor shelter for your outdoor tools.
SUPER SHED Indoor shelter for your outdoor tools. Not everyone needs a garden shed. But, if you've no more space on your garage wall for that new leaf rake, if you can't find your potting trowel because
More informationLödige Goods Passenger Lifts
Lödige Goods Passenger Lifts OLYMPUS-Series Goods Lifts TRAFFICO Car Lifts TECHNOLOGY IN MOTION Service Intralogistik Systems Machines Lifts Road Lödige Industries Technology in Motion The core competence
More informationSeries 5100 Vinyl Replacement
Series 5100 Vinyl Replacement Windows Series 5100 For remodeling projects which call for the classic styling of double hung or the convenience of sliding windows, look no further than the 5100 series for
More informationHOW TO LOAD A TRUCK OR A CONTAINER IN 5 MINUTES? www.progecovigo.com
AUTOMATIC LOADING SYSTEMS HOW TO LOAD A TRUCK OR A CONTAINER IN 5 MINUTES? www.progecovigo.com 1 LOADING PLATFORM TYPES ADJUSTABLE HEIGHT PLATFORMS PF-V DESIGNED FOR LOADING OR UNLOADING OF TRUCKS AND
More informationRef: GA13UK Glass Awning Support System
Ref: GA13UK Glass Awning Support System Give any entrance an uncomplicated, graceful look, enhancing the design of any building. Installation LAMINATED TOUGHENED GLASS High grade 316 stainless steel for
More information6' 7-1/2" SIZE TABLES Aluminum-Clad Exterior
6' 7-1/2" SIZE TABLES 2' 7 1/ 2" (800) 3' 1 1/ 2" 2' 6 3 / 4" (781) 3' 0 3 / 4" (953) 4' 1 1/ 2" (1 257) (933) 4' 0 3 / 4" (1 238) 3180 3780 4980 5' 0" 4' 11 (1 524) 6' 0" (1 505) 5' 11 (1 829) 8' 0" (2
More information39HQ Airovision Air Handling Units
39HQ Airovision Air Handling Units Mounting instructions CONTENTS 1 - TRANSPORT AND LIFTING INSTRUCTIONS... 3 1.1 - General... 3 1.2 - Transport and storage... 3 1.3 - Roof edge protection during transport
More informationMAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015
MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015 **Disclaimer: This document is to serve as informational purposes only. This is not a code book or a final interpretation of the
More informationExperienced Marine Design and Data Use
Experienced Marine Design and Data Use A White Paper Process, Power & Marine, a division of Intergraph Table of Contents 1. Executive Summary... 1 2. Introduction... 2 3. Data Reuse...3 4. Design Reuse...
More informationChapter 2. Basic Airplane Anatomy. 2008 Delmar, Cengage Learning
Chapter 2 Basic Airplane Anatomy Objectives Identify components of basic aircraft anatomy Understand aircraft size and weight categories List different types and examples of General aviation aircraft Military
More informationTalk-A-Phone Co. Model WEBS-MT/R Emergency Phone Tower Mount Architectural & Engineering Specification rev. 08/29/2011
Talk-A-Phone Co. Model WEBS-MT/R Emergency Phone Tower Mount Architectural & Engineering Specification rev. 08/29/2011 1 General Description 2 Construction 1.1 The unit shall be a highly vandal-resistant
More informationSOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
More informationPREASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS
SYSTEM COMPONENTS PREASSEMBLED ELEMENTS FOR FIFTING AND SLIDING DOORS s r ood gn i d i l s dna gn i t f i f r o f s t neme l e de l bme s s ae r P PREASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS These
More informationOctober 30, 2014. Mr. & Mrs. Daniel Vick 101 Southwind Cove Benton, AR. Report of Findings, Structural Investigation, Benton, Arkansas, Dear Mr.
117 S. Market St. Benton, AR 72015 * 501-315-2626 * Fax 501-315-0024 October 30, 2014 Mr. & Mrs. Daniel Vick 101 Southwind Cove Benton, AR Re: Report of Findings,, Benton, Arkansas, Dear Mr. Vick: This
More informationTalk-A-Phone Co. Model WEBS-MT/R OP5 Emergency Phone Tower Mount Architectural & Engineering Specification rev. 10/28/2011
Talk-A-Phone Co. Model WEBS-MT/R OP5 Emergency Phone Tower Mount Architectural & Engineering Specification rev. 10/28/2011 1 General Description 2 Construction 1.1 The unit shall be a highly vandal-resistant
More informationNumber of Sides Required to Have a Handrail
Excerpt from 2012 B.C. Building Code HANDRAILS & GUARDS 9.8.7. Handrails 9.8.7.1. Required Handrails 1) Except as provided in Sentences (2) to (4), handrails shall be installed on stairs and ramps in accordance
More informationModule Title: General Ship Knowledge
CORK INSTITUTE OF TECHNOLOGY INSTITIÚID TEICNEOLAÍOCHTA CHORCAÍ Semester 1 FINAL Examinations 2009/10 School: National Maritime College of Ireland Programme Title: Bachelor of Science (Ordinary) in Nautical
More informationhttp://www.iccsafe.org/
Sections R311 and R312 from the 2006 International Residential Code These sections of Chapter 3 of the 2006 International Residential Code for One and Two Family Dwellings (R311 and R312) including the
More informationCONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION
CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION General 7 www.meadowburke.com 877-518-7665 MB1109 CONCRETE FLOOR SLAB AND CASTING BED CONSTRUCTION Quality Construction Begins at Ground Level Everything
More informationEAST LYME HIGH SCHOOL
Overview: 1971 N 1966 GYM 1966 CLASSROOM WING 1966 AUD. 1971 GYM 1998 1998 POOL EAST LYME HIGH SCHOOL Original 1966 Building: The original East Lyme High School was constructed in 1966 and was composed
More information-1- SPECIFICATIONS 002085 CONE SETTER PLATFORM ATTACHMENT INDEX
-1-002085 CONE SETTER PLATFORM ATTACHMENT INDEX I. GENERAL EQUIPMENT : A. Intent Statement B. Cone Setter Platform II. III. 1. Understructure Frame 2. Mounting Components 3. Paint 4. Basket 5. Labels 6.
More informationCustomer: Cardiff Hospital NHS (United Kingdom) Machine:
Customer: Cardiff Hospital NHS (United Kingdom) Machine: Bench for leak test Model: Easy TS Page 1 of 7 Date: 6 th March 2012 1. Introduction. Easy TS is a compact and reliable table top bench designed
More informationFatigue Assessment. CSR Harmonisation. Content. Industry Presentation
CSR Harmonisation Fatigue Assessment Industry Presentation September 2012 Philippe Baumans & Åge Bøe Project Management Team (PMT) Content Basis acceptance criteria Fatigue loads Loading condition for
More informationRemovable Aluminium posts
Post Solent Sail Shades Ltd 120 Billington Gardens Hedge End Southampton SO30 2RT Tel/Fax: 01489 788243 www.solentsailshades.co.uk Email: info@solentsailshades.co.uk Removable Aluminium posts Single Pole
More informationInstallation Instructions Avalanche XUV Cap IMPORTANT! IMPORTANT!
Installation Instructions Avalanche XUV Cap IMPORTANT! Read all instructions carefully before commencing any work. Always wear safety equipment. Some installation steps will require two or more installers.
More informationHollow or Cinder Block Wall Mount Job Aid
Summary This Job Aid covers: Hollow or Cinder Block Wall Mount Job Aid Hollow or Cinder Block wall Mount Bracket Installing the Mount Bracket into Cinder Block This Job Aid supports the Technician audience.
More informationHistory. between Consilium & Toftejorg. Toftejorg A/S. 1/1-2003 Acquired by Alfa Laval Group. www.alfalaval.com. Alfa Laval Slide 3
History Toftejorg 1953 1 st dual nozzle machine developed by Mr Tofte and Mr Jörgensen (Superintendent of Maersk) 1957 Company Tofte & Jorgensen was formed 1986 Toftejorg was formed Gunclean 1965 Seatrial
More informationThis handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Residential Decks Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
More information2001/069. Decks, stairways,gangways and their associated handrails OFFSHORE TECHNOLOGY REPORT HSE
HSE Health & Safety Executive Decks, stairways,gangways and their associated handrails Prepared by Bomel Ltd for the Health and Safety Executive OFFSHORE TECHNOLOGY REPORT 2001/069 HSE Health & Safety
More informationTECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE
TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE TECHNICAL SPECIFICATION PART 8000 - PRECAST CONCRETE TABLE OF CONTENTS Item Number Page 8100 PRECAST CONCRETE CONSTRUCTION - GENERAL 8-3 8101 General
More informationLoads Tools Checks Reports
Loads Tools Checks Reports SDC Verifier or the Structural Design Code Verifier is a powerful postprocessor program with an advanced calculation core which works seamlessly with Siemens multi-solver, FEA
More informationHorizontal Mini Blinds Installation Guide
Horizontal Mini Blinds Installation Guide We make it easy! BTG 468298 EN_ rev0614 For more safety information: 1-866-662-0666 or.www.healthcanada.gc.ca/blindcords Before starting Your new Blinds To Go
More informationCONTE NT DESIGN PROCESS. Appendix. 01 First Issue. 02 Revision A. 03 Revision B. 04 Co-ordination. 05 Panel Thicknesses. 06 Panel Surface Quality
CONTE NT DESIGN PROCESS First Issue 02 Revision A 03 Revision B 04 Co-ordination 05 Panel Thicknesses 06 Panel Surface Quality 07 CNC Timber Processing 08 Panel Standard Sizes 09 Glulam Standard Sizes
More informationCeiling Mounted Folding Attic Ladders Installation Instructions
Ceiling Mounted Folding Attic Ladders Installation Instructions WARNING Before you start installing your new Louisville Ceiling Mounted Folding Attic Ladder, you must read and understand the following:
More informationUNDERGROUND ELECTRIC TEMPORARY SERVICE PANEL
S 1.0 INDEX 1.0 INDEX 2.0 PURPOSE 3.0 CUSTOMER RESPONSIBILITY FOR TOTAL TEMPORARY SERVICE 4.0 CUSTOMER RESPONSIBILITY FOR TEMPORARY SERVICE IN PERMANENT LOCATION 5.0 NVE RESPONSIBILITIES 6.0 GROUNDING
More informationSHIPWORKS SHIPWORKS. www.althima.com
ShipWorks allows users to design and prepare to production 100% of: ship structure, hull s sheet metal plates, mechanical parts, tubing and deck equipment. SHIPWORKS ShipWorks is based upon a new technology
More informationAIRPORT LOGISTICS SOLUTIONS FOR AIRPORT LOGISTICS. Air Cargo Terminal Equipment
AIRPORT LOGISTICS SOLUTIONS FOR AIRPORT LOGISTICS Air Cargo Terminal Equipment WWW.LODIGE.COM AIRPORT LOGISTICS OVERVIEW TERMINAL EQUIPMENT AIRPORT LOGISTICS OVERVIEW TERMINAL EQUIPMENT ROLLER CONVEYORS
More informationVinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows
Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows Viewed from the exterior. IMPORTANT: Please read before you begin installation. TABLE OF CONTENTS AND TOOL / MATERIAL
More informationTechnical Information
Technical Information This section of the catalogue provides technical information that will help specify, install and maintain Surelock McGill devices and components. The topics are listed below: Blast
More informationHMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES
HOLLOW METAL MANUAL NAAMM STANDARD HMMA 810-87 8d METAL DOORS & FRAMES NAAMM 2 87 HOLLOW METAL HOLLOW METAL DOORS FOURTH EDITION NAAMM 2 87 8d METAL DOORS & FRAMES A Division of NATIONAL ASSOCIATION OF
More informationElectrical Wiring Technical Bulletin
Electrical Wiring Technical Bulletin Overview In general, SIP construction is easier and more cost effective when things are planned and thought out before the panels are manufactured. This process will
More informationEXTeRUS. EXTeRUS - With patented design, able to join technology. and quality of materials with a charming shape. Unique
EXTeR US G L A S S - With patented design, able to join technology and quality of materials with a charming shape. Unique thanks to its outstanding loading capability with 150 kg maximum weight and height
More informationOSHA GUIDANCE DOCUMENT FALL PROTECTION IN RESIDENTIAL CONSTRUCTION
OSHA GUIDANCE DOCUMENT FALL PROTECTION IN RESIDENTIAL CONSTRUCTION OSHA GUIDANCE DOCUMENT FALL PROTECTION IN RESIDENTIAL CONSTRUCTION Table of Contents Executive Summary... 1 Introduction... 1 Installing
More informationSafety. Fire Resistant. Gas Cylinder
All Cabinets Ship Flyer CAB09...Many in 48 hrs. Heavy Duty All Welded CABINETS 31 Models Safety Fire Resistant Spill Containment Gas Cylinder Made in USA Distributed By: Our Quality Serves You Longer JAMCO
More informationSL30-ISO PROFILE SYSTEM
AESTHETICS AND sustainability SL30-ISO PROFILE SYSTEM TECHNICAL DOCuMENTATION WWW.MHB.NL SL30-ISO PROFILE SYSTEM 1. SL30-ISO and SL30-ISO-PLUS Sustainability is getting worldwide more and more the attention
More information