CATALOGUE CARD WATERTIGHT DOORS

Size: px
Start display at page:

Download "CATALOGUE CARD WATERTIGHT DOORS"

Transcription

1 HYDROSTER Ltd. Phone: (48 58) , fax (48 58) , CATALOGUE CARD WATERTIGHT DOORS 1. Watertight door KKA-57704/10.02 page 1 2. Watertight door KKA-57705/10.02 page 3 3. Watertight door KKA-57706/10.02 page 5 4. Watertight door KKA-57708/10.02 page 7 5. Watertight door KKA-57710/10.02 page 9 6. Watertight door KKA-57711/10.02 page Watertight door KKA-57715/10.02 page Watertight door KKA-57716/10.02 page Watertight door KKA-57717/10.02 page Watertight door KKA-57718/10.02 page Watertight door KKA-57719/10.02 page Watertight door KKA-57720/10.02 page 23

2 Watertight door With electro-hydraulic drive KKA-57704/10.02 Page 1/24 1. DESIGNATION The watertight door is designed for tight closing of communication passages in watertight bulkheads of sea-going cargo ships. A Type of watertight closure WD3 A Type of watertight closure WD3.1 The drawing shows the door closed on right.

3 Page 2/24 KKA-57704/10.02 Watertight door HYDROSTER 2. TECHNICAL CHARACTERISTICS 2.1. The watertight door meets the requirements of Convention SOLAS and requirements of Classification Societies. Rules and receipt of Classification Societies and Institutions should be agreed with the producer The steel welded construction of door. The door is installed by direct welding of door s frame to the watertight bulkhead The horizontal direction of door s slide motion. The direction of closing is determined by looking on the watertight closure from the side of drive unit. The selection of closing direction should be given in an order The admissible load is determined by a customer. The admissible load of door is expressed by maximal pressure of water column loading the door. The height of water column is measured from the lower edge of door s hole to the lower surface of bulkhead deck plating in the plane of ship symmetry Electro-hydraulic drive installed on the closure (door). 3. STRUCTURE OF DENOMINATION OF WATERTIGHT DOOR Type of watertight door WD3, WD3.1 High of door in the light of frame - H Width of door in the light of frame - B Direction of closing P - right, L - left Admissible load of door (kpa) WD3- x - Additional requirements determined in the descriptive way (to be agreed with producer) E. g. : the receipt by Classification Society, supply voltage etc. 2. WAY OF ORDERING In the order there should be given: Name: Watertight door Discriminant: acc. to it. 3 No. of catalogue card: KKA-57704/10.02 The example: Watertight door WD3-2000x800P-60 acc. to KKA-57704/10.02 Manufacturer: HYDROSTER Ltd. ph.: (48 58) fax (48 58) market@hydroster.com.pl

4 Watertight door with electro-hydraulic drive KKA-57705/10.02 Strona 3/24 1. DESIGNATION The watertight door is designed for tight closing of communication passages in watertight bulkheads of sea-going passenger ships. A Type of watertight closure WD4 A Type of watertight closure WD4.1 The drawing shows the closure closed on right.

5 Strona 4/24 KKA-57705/10.02 Watertight door HYDROSTER 2. TECHNICAL CHARACTERISTICS 2.1. The watertight door meets the requirements of Convention SOLAS and requirements of Classification Societies. Rules and receipt of Classification Societies and Institutions should be agreed with the producer The steel welded construction of door. The door is installed by direct welding of door s frame to the watertight bulkhead The horizontal direction of door s slide motion. The direction of closing is determined by looking on the watertight door from the side of drive unit. The selection of closing direction should be given in an order The admissible load is determined by a customer. The admissible load of door is expressed by maximal pressure of water column loading the door. The height of water column is measured from the lower edge of door s hole to the lower surface of bulkhead deck plating in the plane of ship symmetry Electro-hydraulic drive installed on the closure (door). 3. STRUCTURE OF DENOMINATION OF WATERTIGHT CLOSURE Type of watertight door WD4, WD4.1 High of door in the light of frame - H Width of door in the light of frame - B Direction of closing P - right, L - left Admissible load of door (kpa) WD4- x - Additional requirements determined in the descriptive way (to be agreed with producer) E. g. : the receipt by Classification Society, supply voltage etc. 2. WAY OF ORDERING In the order there should be given: Name: Watertight door Discriminant: acc. to it. 3 No. of catalogue card: KKA-57705/10.02 The example: Watertight door WD4-2000x800P-60 acc. to KKA-57705/10.02 Manufacturer: HYDROSTER Ltd. ph.: (48 58) fax (48 58) market@hydroster.com.pl

6 Watertight door with electro-hydraulic drive KKA-57706/10.02 Page 5/24 1. DESIGNATION The watertight door is designed for tight closing of communication passages in watertight bulkheads of sea-going ships. The drawing shows the door closed on right.

7 Page 6/24 KKA-57706/10.02 Watertight door HYDROSTER 2. TECHNICAL CHARACTERISTICS 2.1. The watertight door meets the requirements of Convention SOLAS and requirements of Classification Societies. Rules and receipt of Classification Societies and Institutions should be agreed with the producer The steel welded construction of door. The door is installed by direct welding of door s frame to the watertight bulkhead The horizontal direction of door s slide motion. The direction of closing is determined by looking on the watertight door from the side of drive unit. The selection of closing direction should be given in an order The admissible load is determined by a customer. The admissible load of door is expressed by maximal pressure of water column loading the door. The height of water column is measured from the lower edge of door s hole to the lower surface of bulkhead deck plating in the plane of ship symmetry The device consists of watertight door with individual hydraulic drive mounted by Shipyard near the door. The hydraulic drive can be executed for cargo or passenger ships or other solutions (e.g. manual drive). 3. STRUCTURE OF DENOMINATION OF WATERTIGHT DOOR Type of watertight door High of door in the light of frame - H Width of door in the light of frame - B Direction of closing P - right, L - left Admissible load of door (kpa) WD6- x - Additional requirements determined in the descriptive way (to be agreed with producer) E. g. : the receipt by Classification Society, supply voltage etc. 2. WAY OF ORDERING In the order there should be given: Name: Watertight door Discriminant: acc. to it. 3 No. of catalogue card: KKA-57706/10.02 The example: Watertight door WD6-2000x800P-60 acc. to KKA-57706/10.02 Manufacturer: HYDROSTER Ltd. ph.: (48 58) fax (48 58) market@hydroster.com.pl

8 Watertight door With electro-hydraulic drive Low sill door KKA-57708/10.02 Page 7/24 1. DESIGNATION The watertight door with low sill is designed for tight closing of communication passages in watertight bulkheads of sea-going cargo ships. The drawing shows the door closed on right. Low sill door used with concrete used with ramp

9 Page 8/24 KKA-57708/10.02 Watertight door HYDROSTER 2. TECHNICAL CHARACTERISTICS 2.1. The watertight door meets the requirements of Convention SOLAS and requirements of Classification Societies. Rules and receipt of Classification Societies and Institutions should be agreed with the producer The steel welded construction of door. The door is installed by direct welding of door s frame to the watertight bulkhead The horizontal direction of door s slide motion. The direction of closing is determined by looking on the watertight door from the side of drive unit. The selection of closing direction should be given in an order The admissible load is determined by a customer. The admissible load of door is expressed by maximal pressure of water column loading the door. The height of water column is measured from the lower edge of door s hole to the lower surface of bulkhead deck plating in the plane of ship symmetry Electro-hydraulic drive installed on the door. 3. STRUCTURE OF DENOMINATION OF WATERTIGHT DOOR Type of watertight door High of door in the light of frame - H Width of door in the light of frame - B Direction of closing P - right, L - left Admissible load of door (kpa) WD1.0- x - Additional requirements determined in the descriptive way (to be agreed with producer) E. g. : the receipt by Classification Society, supply voltage etc. 2. WAY OF ORDERING In the order there should be given: Name: Watertight door Discriminant: acc. to it. 3 No. of catalogue card: KKA-57708/10.02 The example: Watertight door WD x800P-60 acc. to KKA-57708/10.02 Manufacturer: HYDROSTER Ltd. ph.: (48 58) fax (48 58) market@hydroster.com.pl

10 Watertight door With electro-hydraulic drive Low sill door KKA-57710/10.02 Page 9/24 1. DESIGNATION The watertight door with low sill is designed for tight closing of communication passages in watertight bulkheads of sea-going passenger ships. The drawing shows the door closed on right. Low sill door used with concrete used with ramp

11 Page 10/24 KKA-57710/10.02 Watertight door HYDROSTER 2. TECHNICAL CHARACTERISTICS 2.1. The watertight door meets the requirements of Convention SOLAS and requirements of Classification Societies. Rules and receipt of Classification Societies and Institutions should be agreed with the producer The steel welded construction of door. The door is installed by direct welding of door s frame to the watertight bulkhead The horizontal direction of door s slide motion. The direction of closing is determined by looking on the watertight door from the side of drive unit. The selection of closing direction should be given in an order The admissible load is determined by a customer. The admissible load of door is expressed by maximal pressure of water column loading the door. The height of water column is measured from the lower edge of door s hole to the lower surface of bulkhead deck plating in the plane of ship symmetry Electro-hydraulic drive installed on the door. 3. STRUCTURE OF DENOMINATION OF WATERTIGHT DOOR Type of watertight door High of door in the light of frame - H Width of door in the light of frame - B Direction of closing P - right, L - left Admissible load of door (kpa) WD2- x - Additional requirements determined in the descriptive way (to be agreed with producer) E. g. : the receipt by Classification Society, supply voltage etc. 2. WAY OF ORDERING In the order there should be given: Name: Watertight door Discriminant: acc. to it. 3 No. of catalogue card: KKA-57710/10.02 The example: Watertight door WD2-2000x800P-60 acc. to KKA-57710/10.02 Manufacturer: HYDROSTER Ltd. ph.: (48 58) fax (48 58) market@hydroster.com.pl

12 Watertight door With electro-hydraulic drive Low sill door KKA-57711/10.02 Page 11/24 1. DESIGNATION The watertight door with low sill is designed for tight closing of communication passages in watertight bulkheads of sea-going passenger ships. The drawing shows the closure closed on right. Low sill door used with concrete used with ramp

13 Page 12/24 KKA-57711/10.02 Watertight door HYDROSTER 2. TECHNICAL CHARACTERISTICS 2.1. The watertight door meets the requirements of Convention SOLAS and requirements of Classification Societies. Rules and receipt of Classification Societies and Institutions should be agreed with the producer The steel welded construction of door. The door is installed by direct welding of door s frame to the watertight bulkhead The horizontal direction of door s slide motion. The direction of closing is determined by looking on the watertight door from the side of drive unit. The selection of closing direction should be given in an order The admissible load is determined by a customer. The admissible load of door is expressed by maximal pressure of water column loading the door. The height of water column is measured from the lower edge of door s hole to the lower surface of bulkhead deck plating in the plane of ship symmetry Electro-hydraulic drive installed on the door. 3. STRUCTURE OF DENOMINATION OF WATERTIGHT CLOSURE Type of watertight door High of door in the light of frame - H Width of door in the light of frame - B Direction of closing P - right, L - left Admissible load of door (kpa) WD3- x - Additional requirements determined in the descriptive way (to be agreed with producer) E. g. : the receipt by Classification Society, supply voltage etc. 2. WAY OF ORDERING In the order there should be given: Name: Watertight door Discriminant: acc. to it. 3 No. of catalogue card: KKA-57711/10.02 The example: Watertight door WD3-2000x800P-60 acc. to KKA-57711/10.02 Manufacturer: HYDROSTER Ltd. ph.: (48 58) fax (48 58) market@hydroster.com.pl

14 Watertight door with electric drive Low sill door KKA-57715/10.01 Page 13/24 1. DESIGNATION The watertight door with low sill is designed for tight closing of communication passages in watertight bulkheads of sea-going passenger ships and yachts. The drawing shows the door closed on right. Low sill door used with concrete used with ramp

15 page 14/24 KKA-57715/10.01 Watertight door HYDROSTER 2. TECHNICAL CHARACTERISTICS 2.1. The watertight door meets the requirements of Convention SOLAS and requirements of Classification Societies. Rules and receipt of Classification Societies and Institutions should be agreed with the producer The steel welded construction of door. The door is installed by direct welding of door s frame to the watertight bulkhead The horizontal direction of door s slide motion. The direction of closing is determined by looking on the watertight door from the side of slide. The selection of closing direction should be given in an order The admissible load is determined by a customer. The admissible load of door is expressed by maximal pressure of water column loading the door. The height of water column is measured from the lower edge of door s hole to the lower surface of bulkhead deck plating in the plane of ship symmetry. 3. STRUCTURE OF DENOMINATION OF WATERTIGHT DOOR Type of watertight door High of door in the light of frame - H Width of door in the light of frame - B Direction of closing: P - right, L - left Admissible load of door (kpa) WDE1- x - Additional requirements determined in the descriptive way (to be agreed with producer) E. g. : the receipt by Classification Society, supply voltage etc. 4. WAY OF ORDERING In the order there should be given: Name: Watertight door Discriminant: acc. to it. 3 No. of catalogue card: KKA-57715/10.01 The example: Watertight door WDE1-2000x800P-60 acc. to KKA-57715/10.01 Manufacturer: HYDROSTER Ltd. ph.: (48 58) fax (48 58) market@hydroster.com.pl

16 Watertight door with electric drive KKA-57716/10.01 Page 15/24 1. DESIGNATION The watertight door with low sill is designed for tight closing of communication passages in watertight bulkheads of sea-going passenger ships and yachts. The drawing shows the door closed on right.

17 page 16/24 KKA-57716/10.01 Watertight door HYDROSTER 2. TECHNICAL CHARACTERISTICS 2.1. The watertight door meets the requirements of Convention SOLAS and requirements of Classification Societies. Rules and receipt of Classification Societies and Institutions should be agreed with the producer The steel welded construction of door. The door is installed by direct welding of door s frame to the watertight bulkhead The horizontal direction of door s slide motion. The direction of closing is determined by looking on the watertight closure from the side of slide. The selection of closing direction should be given in an order The admissible load is determined by a customer. The admissible load of door is expressed by maximal pressure of water column loading the door. The height of water column is measured from the lower edge of door s hole to the lower surface of bulkhead deck plating in the plane of ship symmetry. 3. STRUCTURE OF DENOMINATION OF WATERTIGHT DOOR Type of watertight door: WDE2, WDE2.1 High of door in the light of frame - H Width of door in the light of frame - B Direction of closing: P - right, L - left Admissible load of door (kpa) WDE2- x - Additional requirements determined in the descriptive way (to be agreed with producer) E. g. : the receipt by Classification Society, supply voltage etc. 4. WAY OF ORDERING In the order there should be given: Name: Watertight door Discriminant: acc. to it. 3 No. of catalogue card: KKA-57716/10.01 The example: Watertight door WDE2-2000x800P-60 acc. to KKA-57716/10.01 WDE x800P-60 acc. to KKA-57716/10.01 Manufacturer: HYDROSTER Ltd. ph.: (48 58) fax (48 58) market@hydroster.com.pl

18 Watertight door with electric drive Low sill door with slim control panel KKA-57717/10.01 Page 17/24 1. DESIGNATION The watertight door with low sill is designed for tight closing of communication passages in watertight bulkheads of sea-going passenger ships and yachts. The drawing shows the door closed on right. Low sill door used with concrete used with ramp

19 page 18/24 KKA-57717/10.01 Watertight door HYDROSTER 2. TECHNICAL CHARACTERISTICS 2.1. The watertight door meets the requirements of Convention SOLAS and requirements of Classification Societies. Rules and receipt of Classification Societies and Institutions should be agreed with the producer The steel welded construction of door. The door is installed by direct welding of door s frame to the watertight bulkhead The horizontal direction of door s slide motion. The direction of closing is determined by looking on the watertight closure from the side of slide. The selection of closing direction should be given in an order The admissible load is determined by a customer. The admissible load of door is expressed by maximal pressure of water column loading the door. The height of water column is measured from the lower edge of door s hole to the lower surface of bulkhead deck plating in the plane of ship symmetry. 3. STRUCTURE OF DENOMINATION OF WATERTIGHT DOOR Type of watertight door High of door in the light of frame - H Width of door in the light of frame - B Direction of closing: P - right, L - left Admissible load of door (kpa) WDE3- x - Additional requirements determined in the descriptive way (to be agreed with producer) E. g. : the receipt by Classification Society, supply voltage etc. 4. WAY OF ORDERING In the order there should be given: Name: Watertight door Discriminant: acc. to it. 3 No. of catalogue card: KKA-57717/10.01 The example: Watertight door WDE3-2000x800P-60 acc. to KKA-57717/10.01 Manufacturer: HYDROSTER Ltd. ph.: (48 58) fax (48 58) market@hydroster.com.pl

20 Watertight door with electric drive Slim control panel KKA-57718/10.01 Page 19/24 1. DESIGNATION The watertight door with low sill is designed for tight closing of communication passages in watertight bulkheads of sea-going passenger ships and yachts. The drawing shows the door closed on right.

21 page 20/24 KKA-57718/10.01 Watertight door HYDROSTER 2. TECHNICAL CHARACTERISTICS 2.1. The watertight door meets the requirements of Convention SOLAS and requirements of Classification Societies. Rules and receipt of Classification Societies and Institutions should be agreed with the producer The steel welded construction of door. The door is installed by direct welding of door s frame to the watertight bulkhead The horizontal direction of door s slide motion. The direction of closing is determined by looking on the watertight closure from the side of slide. The selection of closing direction should be given in an order The admissible load is determined by a customer. The admissible load of door is expressed by maximal pressure of water column loading the door. The height of water column is measured from the lower edge of door s hole to the lower surface of bulkhead deck plating in the plane of ship symmetry. 3. STRUCTURE OF DENOMINATION OF WATERTIGHT DOOR Type of watertight door: WDE4, WDE4.1 High of door in the light of frame - H Width of door in the light of frame - B Direction of closing: P - right, L - left Admissible load of door (kpa) WDE4- x - Additional requirements determined in the descriptive way (to be agreed with producer) E. g. : the receipt by Classification Society, supply voltage etc. 4. WAY OF ORDERING In the order there should be given: Name: Watertight door Discriminant: acc. to it. 3 No. of catalogue card: KKA-57718/10.01 The example: Watertight door WDE4-2000x800P-60 acc. to KKA-57718/10.01 WDE x800P-60 acc. to KKA-57718/10.01 Manufacturer: HYDROSTER Ltd. ph.: (48 58) fax (48 58) market@hydroster.com.pl

22 Watertight door with electric drive Low sill door without control panel KKA-57719/10.01 Page 21/24 1. DESIGNATION The watertight door with low sill is designed for tight closing of communication passages in watertight bulkheads of sea-going passenger ships and yachts. Elements of panel to be fitted separately at yard s/owner convenience. The drawing shows the door closed on right. Low sill door used with concrete used with ramp

23 page 22/24 KKA-57719/10.01 Watertight door HYDROSTER 2. TECHNICAL CHARACTERISTICS 2.1. The watertight door meets the requirements of Convention SOLAS and requirements of Classification Societies. Rules and receipt of Classification Societies and Institutions should be agreed with the producer The steel welded construction of door. The door is installed by direct welding of door s frame to the watertight bulkhead The horizontal direction of door s slide motion. The direction of closing is determined by looking on the watertight closure from the side of slide. The selection of closing direction should be given in an order The admissible load is determined by a customer. The admissible load of door is expressed by maximal pressure of water column loading the door. The height of water column is measured from the lower edge of door s hole to the lower surface of bulkhead deck plating in the plane of ship symmetry. 3. STRUCTURE OF DENOMINATION OF WATERTIGHT DOOR Type of watertight door High of door in the light of frame - H Width of door in the light of frame - B Direction of closing: P - right, L - left Admissible load of door (kpa) WDE5- x - Additional requirements determined in the descriptive way (to be agreed with producer) E. g. : the receipt by Classification Society, supply voltage etc. 4. WAY OF ORDERING In the order there should be given: Name: Watertight door Discriminant: acc. to it. 3 No. of catalogue card: KKA-57719/10.01 The example: Watertight door WDE5-2000x800P-60 acc. to KKA-57719/10.01 Manufacturer: HYDROSTER Ltd. ph.: (48 58) fax (48 58) market@hydroster.com.pl

24 Watertight door with electric drive Without control panel KKA-57720/10.01 Page 23/24 1. DESIGNATION The watertight door with low sill is designed for tight closing of communication passages in watertight bulkheads of sea-going passenger ships and yachts. Elements of panel to be fitted separately at yard s/owner convenience. The drawing shows the door closed on right.

25 page 24/24 KKA-57720/10.01 Watertight door HYDROSTER 2. TECHNICAL CHARACTERISTICS 2.1. The watertight door meets the requirements of Convention SOLAS and requirements of Classification Societies. Rules and receipt of Classification Societies and Institutions should be agreed with the producer The steel welded construction of door. The door is installed by direct welding of door s frame to the watertight bulkhead The horizontal direction of door s slide motion. The direction of closing is determined by looking on the watertight closure from the side of slide. The selection of closing direction should be given in an order The admissible load is determined by a customer. The admissible load of door is expressed by maximal pressure of water column loading the door. The height of water column is measured from the lower edge of door s hole to the lower surface of bulkhead deck plating in the plane of ship symmetry. 3. STRUCTURE OF DENOMINATION OF WATERTIGHT DOOR Type of watertight door High of door in the light of frame - H Width of door in the light of frame - B Direction of closing: P - right, L - left Admissible load of door (kpa) WDE6- x - Additional requirements determined in the descriptive way (to be agreed with producer) E. g. : the receipt by Classification Society, supply voltage etc. 4. WAY OF ORDERING In the order there should be given: Name: Watertight door Discriminant: acc. to it. 3 No. of catalogue card: KKA-57720/10.01 The example: Watertight door WDE6-2000x800P-60 acc. to KKA-57720/10.01 Manufacturer: HYDROSTER Ltd. ph.: (48 58) fax (48 58) market@hydroster.com.pl

Access in motion. Watertight Bulkhead Doors. Ventilation Duct Closing Systems. Hydraulic Marine Systems For Special Applications.

Access in motion. Watertight Bulkhead Doors. Ventilation Duct Closing Systems. Hydraulic Marine Systems For Special Applications. Access in motion Watertight Bulkhead Doors Ventilation Duct Closing Systems Hydraulic Marine Systems For Special Applications Shell Doors Watertight Building Doors SCHOENROCK with History Our Business

More information

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES Interpretations of the FTP CONTENTS FTP1 Adhesives used in A or B class divisions (FTP Code 3.1, Res A.754 para. 3.2.3) June 2000 FTP2 Pipe and duct

More information

VLCC Structural Design - Past, Present and Future

VLCC Structural Design - Past, Present and Future TSCF 2007 Shipbuilders Meeting VLCC Structural Design - Past, Present and Future Seong Ki Kim 1), Minsu Cho 2), Theodore W. Kang 3) Sungkon Han 4) and ManSoo Kim 5) 1) Hull Basic Design Team, DSME, Seoul,

More information

19 DYNAmax Free Standing Server C A B I N E T s

19 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide

More information

19 DYNAmax Free Standing Server C A B I N E T s

19 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=600mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide

More information

Aluminium systems profile selection

Aluminium systems profile selection Aluminium systems profile selection The purpose of this document is to summarise the way that aluminium profile selection should be made, based on the strength requirements for each application. Curtain

More information

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

WINDOW AND DOOR REPLACEMENT REQUIREMENTS WINDOW AND DOOR REPLACEMENT REQUIREMENTS Should you have any questions after reading the following information, please call the Building Inspection Department at 651-439-4439 to discuss the topics of concern.

More information

Low Voltage Switchboards The Best Technical Solution for Your Ship

Low Voltage Switchboards The Best Technical Solution for Your Ship The Best Technical Solution for Your Ship Wärtsilä SAM Electronics Optimal Power Distribution The uninterrupted supply of power to systems and consumers onboard modern ships is an extremly important matter.

More information

I N T E R N A T I O N A L R E S I D E N T I A L CO D E

I N T E R N A T I O N A L R E S I D E N T I A L CO D E Visual Interpretation Of The I N T E R N A T I O N A L R E S I D E N T I A L CO D E 2006 STAIR BUILDING CODE Portions of this document reproduce sections from the 2006 International Residential Code, International

More information

Residential Decks. Planning and Development Services Department

Residential Decks. Planning and Development Services Department Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: permitservices@opkansas.org Planning and Development Services Department Residential Decks

More information

Purchasing Services AOC 200 4202 East Fowler Avenue Tampa, Florida 33620 (813) 974-2481. Web Address: http://www.usf.edu/business-finance/purchasing/

Purchasing Services AOC 200 4202 East Fowler Avenue Tampa, Florida 33620 (813) 974-2481. Web Address: http://www.usf.edu/business-finance/purchasing/ Purchasing Services AOC 200 4202 East Fowler Avenue Tampa, Florida 33620 (813) 974-2481 Web Address: http://www.usf.edu/business-finance/purchasing/ January 20, 2016 Invitation to Negotiate No. Entitled:

More information

ARIE KEPETS - SR. VICE PRESIDENT MARCH 09

ARIE KEPETS - SR. VICE PRESIDENT MARCH 09 YOUR ONE STOP SOURCE FOR ALL YOUR CONTAINMENT NEEDS ARIE KEPETS - SR. VICE PRESIDENT MARCH 09 VR CONTAINMENT LLC INC. 176-25 UNION TURNPIKE SUITE 175 FRESH MEADOWS NY 11366 TEL 516 673 4961 FAX 866 286

More information

SSG PRODUCTS FOR SHIPS AND OFFSHORE

SSG PRODUCTS FOR SHIPS AND OFFSHORE 6.1 SSG PRODUCTS FOR SHIPS AND OFFSHORE SSG workshop cabinets, tables and shelving system specially adapted to be used on-board ships and offshore. Developed in close cooperation with users from these

More information

The replacement or modification of existing windows shall comply with the following requirements:

The replacement or modification of existing windows shall comply with the following requirements: City of La Habra Heights Building Division 1245 N. Hacienda Road La Habra Heights, CA 90631 Office: (562) 694-6302 ext. 228 Fax: (562) 690-5010 WINDOW REPLACEMENT 2010 CALIFORNIA RESIDENTIAL CODE (CRC)

More information

Part 0 - Classification and Surveys Classification and Surveys I-0 2016-01

Part 0 - Classification and Surveys Classification and Surveys I-0 2016-01 Code Edition I - Ship Technology Part 0 - Classification and Surveys Classification and Surveys I-0 2016-01 Part 1 - Seagoing Ships Chapter 1 - Hull Structures I-1-1 2016-01 Chapter 1 - Hull Structures

More information

SPECIAL VEHICLES TERBERG RT-SERIES HANDLING HEAVY CARGO WITH TOTAL CONFIDENCE

SPECIAL VEHICLES TERBERG RT-SERIES HANDLING HEAVY CARGO WITH TOTAL CONFIDENCE SPECIAL VEHICLES TERBERG RT-SERIES HANDLING HEAVY CARGO WITH TOTAL CONFIDENCE BASED ON PROVEN DESIGNS Gross Combination Weights up to 375 tonnes Fifth wheel lifting capacity up to 45 tonnes Ergoturn 180

More information

Rules for Classification and Construction Additional Rules and Guidelines

Rules for Classification and Construction Additional Rules and Guidelines VI Rules for Classification and Construction Additional Rules and Guidelines 7 Guidelines for the Performance of Type Approvals 4 Test Requirements for Sealing Systems of Bulkhead and Deck Penetrations

More information

Rule-Based Ship Design

Rule-Based Ship Design Rule-Based Ship Design A White Paper Process, Power & Marine, a division of Intergraph Table of Contents 1. Introduction... 1 2. Advantages to Rule-Based Design... 2 2.1 Embedding Design Practices...2

More information

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-

More information

Linear Motion & Assembly Technologies - Guarding System

Linear Motion & Assembly Technologies - Guarding System Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Linear Motion & Assembly Technologies - Guarding System EcoSafe Guarding System from Rexroth Guarding

More information

TABLE OF CONTENTS. INTRODUCTION... 5 Advance Concrete... 5 Where to find information?... 6 INSTALLATION... 7 STARTING ADVANCE CONCRETE...

TABLE OF CONTENTS. INTRODUCTION... 5 Advance Concrete... 5 Where to find information?... 6 INSTALLATION... 7 STARTING ADVANCE CONCRETE... Starting Guide TABLE OF CONTENTS INTRODUCTION... 5 Advance Concrete... 5 Where to find information?... 6 INSTALLATION... 7 STARTING ADVANCE CONCRETE... 7 ADVANCE CONCRETE USER INTERFACE... 7 Other important

More information

Leaflet for damage stability calculation according to SOLAS 2009

Leaflet for damage stability calculation according to SOLAS 2009 Hamburg 2008-07-23 Version 1.2 Leaflet for damage stability calculation according to SOLAS 2009 Table of contents: 1 Background... 2 2 Intention of this paper...2 3 Formal application... 2 3.1 Application

More information

SERVER ROOM CABINET INSTALLATION CONCEPTS

SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS ZPAS 169 EXAMPLES OF SERVER ROOMS PROJECTS WITH ZPAS CABINETS Data Box in the

More information

CLASSIFICATION NOTES

CLASSIFICATION NOTES CLASSIFICATION NOTES Type Approval, Installation and Testing of Water Level Detectors on Bulk Carriers and Single Hold Cargo Ships other than Bulk Carriers General Information This edition of the classification

More information

Steel Door Frame Installation in Steel Stud Construction

Steel Door Frame Installation in Steel Stud Construction Steel Door Frame Installation in Steel Stud Construction For use with the Steel Door Institute (SDI) video How to Install a Steel Door Frames in Steel Stud Construction This manual gives you step-by-step

More information

A U T O M O T I V E L I F T S

A U T O M O T I V E L I F T S Q U A L I T Y Y O U E X P E C T AT A P R I C E Y O U W O U L D N T T H E S TA N D A R D I N I N F O R M AT I O N, E Q U I P M E N T A N D D I A G N O S T I C S S Y S T E M S h t t p : / / d i a g n o s

More information

GK Packing System Welding Instructions

GK Packing System Welding Instructions GK Packing System Welding Instructions Roxtec GmbH Neuer Höltigbaum 1-3, 22143 Hamburg GERMANY Tel +49 (040) 657398-0, Fax +49 (040) 657398-50 EMAIL info@de.roxtec.com, www.roxtec.de Welding instructions

More information

Packaged Terminal Air Conditioner Wall Sleeve Installation

Packaged Terminal Air Conditioner Wall Sleeve Installation Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation

More information

FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS

FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 INSTALLATION INSTRUCTIONS FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS 11/2 HOUR UL555 RATED UL555S LEAKAGE RATED

More information

GUIDELINES FOR FLOODING DETECTION SYSTEMS ON PASSENGER SHIPS

GUIDELINES FOR FLOODING DETECTION SYSTEMS ON PASSENGER SHIPS INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: 020 7735 7611 Fax: 020 7587 3210 IMO E Ref. T1/2.04 MSC.1/Circ.1291 9 December 2008 GUIDELINES FOR FLOODING DETECTION SYSTEMS

More information

Corrosion protection of crude oil cargo tanks new IMO regulations

Corrosion protection of crude oil cargo tanks new IMO regulations Guidance note oil cargo tanks new IMO regulations Guidance for shipowners and operators, manufacturers and ship builders 1. Background to the new requirements Following incidents resulting from structural

More information

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier A. Requirement This document is to be used to specify the physical and operational

More information

27th session 20 December 2011. Resolution A.1045(27) Adopted on 30 November 2011 (Agenda item 9) PILOT TRANSFER ARRANGEMENTS

27th session 20 December 2011. Resolution A.1045(27) Adopted on 30 November 2011 (Agenda item 9) PILOT TRANSFER ARRANGEMENTS E ASSEMBLY A 27/Res.1045 27th session 20 December 2011 Agenda item 9 Original: ENGLISH Resolution A.1045(27) Adopted on 30 November 2011 (Agenda item 9) PILOT TRANSFER ARRANGEMENTS THE ASSEMBLY, RECALLING

More information

Light-Weight Panels. High quality panels. www.stenca.com

Light-Weight Panels. High quality panels. www.stenca.com Light-Weight Panels High quality panels WELCOME TO STENCA TRADING - Global focus with local service Stenca Trading offers optimal solutions for the offshore, marine, refineries and cogeneration industry.

More information

BLADE S-MAX Cabinet for Blade Server

BLADE S-MAX Cabinet for Blade Server Cabinet for Blade Server 1 2 Overview Material specification Corner verticals: 1.5 mm steel End frames: 1.5 mm steel Panel mounts: 2.0 mm steel Panel mount supports: 1.5 mm steel Side panels, door and

More information

Rear Impact Guard TEST METHOD 223. Standards and Regulations Division. Issued: December 2003

Rear Impact Guard TEST METHOD 223. Standards and Regulations Division. Issued: December 2003 Transport Canada Safety and Security Road Safety Transports Canada Sécurité et sûreté Sécurité routière Standards and Regulations Division TEST METHOD 223 Rear Impact Guard Issued: December 2003 Standards

More information

Damage Reporting Procedures

Damage Reporting Procedures Damage Reporting Procedures Criteria. The criteria for reporting damaged product is: six (6) plies or more of tear damage, wet or water damage rolls and rolls that have crush or core damage. If product

More information

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed

More information

glass & Glazing Products

glass & Glazing Products glass & Glazing Products WallMaker Create an unlimited variety of bright, beautiful and secure interior environments with the easy-to-install Stylmark WallMaker glass wall system. This versatile system

More information

18. SKATES, PLATFORM HAND TRUCKS, LIFTING TABLES AND HAND TROLLEYS

18. SKATES, PLATFORM HAND TRUCKS, LIFTING TABLES AND HAND TROLLEYS 18. SKATES, PLATFORM HAND TRUCKS, LIFTING TABLES AND HAND TROLLEYS SKATES LIFTING TABLES HAND TROLLEYS PLATFORM HAND TRUCKS SKATES SKATE 1500KG for moving machines and equipment duration oiled metal wheels

More information

BARRIER LIFT SYSTEM 2 BARRIER LIFT SYSTEM

BARRIER LIFT SYSTEM 2 BARRIER LIFT SYSTEM BARRIER LIFT SYSTEM BARRIER LIFT SYSTEM The crash rated elkosta Barrier Lift System BLS offers maximum security for highly sensitive entry or exit points against unauthorised vehicles attempting to break

More information

REQUIREMENT 3. Usable Doors

REQUIREMENT 3. Usable Doors Chapter Three: REQUIREMENT 3 Usable Doors 3...covered multifamily dwellings with a building entrance on an accessible route shall be designed in such a manner that all the doors designed to allow passage

More information

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs. Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12

More information

T&B Cable Tray. Metallic Aluminum. Straight Lengths. Tray Bottom Types Ladder, Ventilated and Solid Trough

T&B Cable Tray. Metallic Aluminum. Straight Lengths. Tray Bottom Types Ladder, Ventilated and Solid Trough Tray Bottom Types Ladder Extra wide aluminum rungs are welded to extruded aluminum I-beam siderails. Every second rung is reversed to allow for easy top or bottom mounting of cable ties and clamps. All

More information

We ll help you determine your containment needs

We ll help you determine your containment needs We ll help you determine your containment needs Ask yourself the five questions below for help choosing the right containment products to keep your workplace clean, safe and compliant! For more assistance,

More information

Guidance Note on the Need for Planning Permission for the Development of Existing Houses and Flats (effective from 6 February 2012)

Guidance Note on the Need for Planning Permission for the Development of Existing Houses and Flats (effective from 6 February 2012) de Guidance Note on the Need for Planning Permission for the Development of Existing Houses and Flats (effective from 6 February 2012) Introduction The rules governing permitted development (that is, whether

More information

PRODUCT AND ENGINEERING MANUAL

PRODUCT AND ENGINEERING MANUAL TABLE OF CONTENTS Table of Contents... 1 General Mezzanine Information and Specifications... 2 SM0010PE Mezzanine Plan Information... 3 Information Required for Mezzanine Structures... 4 Floor And/Or Mezzanine

More information

LOADING DOCK EQUIPMENT. A. Section 03100 - Concrete Forms and Accessories: Placement of anchors into concrete.

LOADING DOCK EQUIPMENT. A. Section 03100 - Concrete Forms and Accessories: Placement of anchors into concrete. LOADING DOCK EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Loading dock equipment of the following types: 1. Dock lifts. 2. Control stations. 1.2 RELATED SECTIONS A. Section 03100 - Concrete Forms and

More information

Security Matrix. STCW Regulation (applicable from 1 st of January 2014):

Security Matrix. STCW Regulation (applicable from 1 st of January 2014): Security Matrix Seafarers holding SSO (A VI/5) certificate are not required to obtain Designated Security Duties (A VI/6 2) and Security Awareness (A VI/6 1) certificates Seafarers holding Designated Security

More information

DE Frame with C Series Sidelight

DE Frame with C Series Sidelight TOOLS REQUIRED Tape measure 6' magnetic level 3' magnetic level Screw gun with clutch adjusted #2 phillips tip #3 phillips tip Screwdriver (used to adjust frame on will using oval slots) Pry Bar Powder

More information

GUIDELINES FOR THE DRAINAGE OF FIRE-FIGHTING WATER FROM CLOSED VEHICLE AND RO-RO SPACES AND SPECIAL CATEGORY SPACES OF PASSENGER AND CARGO SHIPS

GUIDELINES FOR THE DRAINAGE OF FIRE-FIGHTING WATER FROM CLOSED VEHICLE AND RO-RO SPACES AND SPECIAL CATEGORY SPACES OF PASSENGER AND CARGO SHIPS INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: 020 7735 7611 Fax: 020 7587 3210 IMO E Ref. T4/4.01 MSC.1/Circ.1320 11 June 2009 GUIDELINES FOR THE DRAINAGE OF FIRE-FIGHTING

More information

Hinge, Blocker, and Tab Adjustment Guide

Hinge, Blocker, and Tab Adjustment Guide Hinge, Blocker, and Guide for Andersen A-Series Hinged Outswing; 400 Series Frenchwood Hinged Outswing Patio Doors and 400 Series Frenchwood Hinged Outswing Patio Doors with Stormwatch Protection Hinge,

More information

2015 PRICES. Interior. WITH AZEK Harvest Bronze, Silver Oak, or Hazelwood

2015 PRICES. Interior. WITH AZEK Harvest Bronze, Silver Oak, or Hazelwood STANDARD SECTIONS WITH DECKING Legs are included up to 8ft long. Standard footpads measure 4 x 14 2015 PRICES WITH CEDAR Western Red (color varies) WITH AZEK Brownstone or Slate Gray WITH AZEK Harvest

More information

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nailing fin. While the use of these installation instructions

More information

M/ Y VARIETY VOYAGER. Ship specifications

M/ Y VARIETY VOYAGER. Ship specifications M/ Y VARIETY VOYAGER Ship specifications YOUR SHIP: THE MOTORYACHT VARIETY VOYAGER The new build 68 m / 223 ft state of the art Mega Yacht will accommodate just 72 passengers in 36 cabins. Built under

More information

SUPER SHED. Indoor shelter for your outdoor tools.

SUPER SHED. Indoor shelter for your outdoor tools. SUPER SHED Indoor shelter for your outdoor tools. Not everyone needs a garden shed. But, if you've no more space on your garage wall for that new leaf rake, if you can't find your potting trowel because

More information

Lödige Goods Passenger Lifts

Lödige Goods Passenger Lifts Lödige Goods Passenger Lifts OLYMPUS-Series Goods Lifts TRAFFICO Car Lifts TECHNOLOGY IN MOTION Service Intralogistik Systems Machines Lifts Road Lödige Industries Technology in Motion The core competence

More information

Series 5100 Vinyl Replacement

Series 5100 Vinyl Replacement Series 5100 Vinyl Replacement Windows Series 5100 For remodeling projects which call for the classic styling of double hung or the convenience of sliding windows, look no further than the 5100 series for

More information

HOW TO LOAD A TRUCK OR A CONTAINER IN 5 MINUTES? www.progecovigo.com

HOW TO LOAD A TRUCK OR A CONTAINER IN 5 MINUTES? www.progecovigo.com AUTOMATIC LOADING SYSTEMS HOW TO LOAD A TRUCK OR A CONTAINER IN 5 MINUTES? www.progecovigo.com 1 LOADING PLATFORM TYPES ADJUSTABLE HEIGHT PLATFORMS PF-V DESIGNED FOR LOADING OR UNLOADING OF TRUCKS AND

More information

Ref: GA13UK Glass Awning Support System

Ref: GA13UK Glass Awning Support System Ref: GA13UK Glass Awning Support System Give any entrance an uncomplicated, graceful look, enhancing the design of any building. Installation LAMINATED TOUGHENED GLASS High grade 316 stainless steel for

More information

6' 7-1/2" SIZE TABLES Aluminum-Clad Exterior

6' 7-1/2 SIZE TABLES Aluminum-Clad Exterior 6' 7-1/2" SIZE TABLES 2' 7 1/ 2" (800) 3' 1 1/ 2" 2' 6 3 / 4" (781) 3' 0 3 / 4" (953) 4' 1 1/ 2" (1 257) (933) 4' 0 3 / 4" (1 238) 3180 3780 4980 5' 0" 4' 11 (1 524) 6' 0" (1 505) 5' 11 (1 829) 8' 0" (2

More information

39HQ Airovision Air Handling Units

39HQ Airovision Air Handling Units 39HQ Airovision Air Handling Units Mounting instructions CONTENTS 1 - TRANSPORT AND LIFTING INSTRUCTIONS... 3 1.1 - General... 3 1.2 - Transport and storage... 3 1.3 - Roof edge protection during transport

More information

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015 MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015 **Disclaimer: This document is to serve as informational purposes only. This is not a code book or a final interpretation of the

More information

Experienced Marine Design and Data Use

Experienced Marine Design and Data Use Experienced Marine Design and Data Use A White Paper Process, Power & Marine, a division of Intergraph Table of Contents 1. Executive Summary... 1 2. Introduction... 2 3. Data Reuse...3 4. Design Reuse...

More information

Chapter 2. Basic Airplane Anatomy. 2008 Delmar, Cengage Learning

Chapter 2. Basic Airplane Anatomy. 2008 Delmar, Cengage Learning Chapter 2 Basic Airplane Anatomy Objectives Identify components of basic aircraft anatomy Understand aircraft size and weight categories List different types and examples of General aviation aircraft Military

More information

Talk-A-Phone Co. Model WEBS-MT/R Emergency Phone Tower Mount Architectural & Engineering Specification rev. 08/29/2011

Talk-A-Phone Co. Model WEBS-MT/R Emergency Phone Tower Mount Architectural & Engineering Specification rev. 08/29/2011 Talk-A-Phone Co. Model WEBS-MT/R Emergency Phone Tower Mount Architectural & Engineering Specification rev. 08/29/2011 1 General Description 2 Construction 1.1 The unit shall be a highly vandal-resistant

More information

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels

More information

PREASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS

PREASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS SYSTEM COMPONENTS PREASSEMBLED ELEMENTS FOR FIFTING AND SLIDING DOORS s r ood gn i d i l s dna gn i t f i f r o f s t neme l e de l bme s s ae r P PREASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS These

More information

October 30, 2014. Mr. & Mrs. Daniel Vick 101 Southwind Cove Benton, AR. Report of Findings, Structural Investigation, Benton, Arkansas, Dear Mr.

October 30, 2014. Mr. & Mrs. Daniel Vick 101 Southwind Cove Benton, AR. Report of Findings, Structural Investigation, Benton, Arkansas, Dear Mr. 117 S. Market St. Benton, AR 72015 * 501-315-2626 * Fax 501-315-0024 October 30, 2014 Mr. & Mrs. Daniel Vick 101 Southwind Cove Benton, AR Re: Report of Findings,, Benton, Arkansas, Dear Mr. Vick: This

More information

Talk-A-Phone Co. Model WEBS-MT/R OP5 Emergency Phone Tower Mount Architectural & Engineering Specification rev. 10/28/2011

Talk-A-Phone Co. Model WEBS-MT/R OP5 Emergency Phone Tower Mount Architectural & Engineering Specification rev. 10/28/2011 Talk-A-Phone Co. Model WEBS-MT/R OP5 Emergency Phone Tower Mount Architectural & Engineering Specification rev. 10/28/2011 1 General Description 2 Construction 1.1 The unit shall be a highly vandal-resistant

More information

Number of Sides Required to Have a Handrail

Number of Sides Required to Have a Handrail Excerpt from 2012 B.C. Building Code HANDRAILS & GUARDS 9.8.7. Handrails 9.8.7.1. Required Handrails 1) Except as provided in Sentences (2) to (4), handrails shall be installed on stairs and ramps in accordance

More information

Module Title: General Ship Knowledge

Module Title: General Ship Knowledge CORK INSTITUTE OF TECHNOLOGY INSTITIÚID TEICNEOLAÍOCHTA CHORCAÍ Semester 1 FINAL Examinations 2009/10 School: National Maritime College of Ireland Programme Title: Bachelor of Science (Ordinary) in Nautical

More information

http://www.iccsafe.org/

http://www.iccsafe.org/ Sections R311 and R312 from the 2006 International Residential Code These sections of Chapter 3 of the 2006 International Residential Code for One and Two Family Dwellings (R311 and R312) including the

More information

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION General 7 www.meadowburke.com 877-518-7665 MB1109 CONCRETE FLOOR SLAB AND CASTING BED CONSTRUCTION Quality Construction Begins at Ground Level Everything

More information

EAST LYME HIGH SCHOOL

EAST LYME HIGH SCHOOL Overview: 1971 N 1966 GYM 1966 CLASSROOM WING 1966 AUD. 1971 GYM 1998 1998 POOL EAST LYME HIGH SCHOOL Original 1966 Building: The original East Lyme High School was constructed in 1966 and was composed

More information

-1- SPECIFICATIONS 002085 CONE SETTER PLATFORM ATTACHMENT INDEX

-1- SPECIFICATIONS 002085 CONE SETTER PLATFORM ATTACHMENT INDEX -1-002085 CONE SETTER PLATFORM ATTACHMENT INDEX I. GENERAL EQUIPMENT : A. Intent Statement B. Cone Setter Platform II. III. 1. Understructure Frame 2. Mounting Components 3. Paint 4. Basket 5. Labels 6.

More information

Customer: Cardiff Hospital NHS (United Kingdom) Machine:

Customer: Cardiff Hospital NHS (United Kingdom) Machine: Customer: Cardiff Hospital NHS (United Kingdom) Machine: Bench for leak test Model: Easy TS Page 1 of 7 Date: 6 th March 2012 1. Introduction. Easy TS is a compact and reliable table top bench designed

More information

Fatigue Assessment. CSR Harmonisation. Content. Industry Presentation

Fatigue Assessment. CSR Harmonisation. Content. Industry Presentation CSR Harmonisation Fatigue Assessment Industry Presentation September 2012 Philippe Baumans & Åge Bøe Project Management Team (PMT) Content Basis acceptance criteria Fatigue loads Loading condition for

More information

Removable Aluminium posts

Removable Aluminium posts Post Solent Sail Shades Ltd 120 Billington Gardens Hedge End Southampton SO30 2RT Tel/Fax: 01489 788243 www.solentsailshades.co.uk Email: info@solentsailshades.co.uk Removable Aluminium posts Single Pole

More information

Installation Instructions Avalanche XUV Cap IMPORTANT! IMPORTANT!

Installation Instructions Avalanche XUV Cap IMPORTANT! IMPORTANT! Installation Instructions Avalanche XUV Cap IMPORTANT! Read all instructions carefully before commencing any work. Always wear safety equipment. Some installation steps will require two or more installers.

More information

Hollow or Cinder Block Wall Mount Job Aid

Hollow or Cinder Block Wall Mount Job Aid Summary This Job Aid covers: Hollow or Cinder Block Wall Mount Job Aid Hollow or Cinder Block wall Mount Bracket Installing the Mount Bracket into Cinder Block This Job Aid supports the Technician audience.

More information

History. between Consilium & Toftejorg. Toftejorg A/S. 1/1-2003 Acquired by Alfa Laval Group. www.alfalaval.com. Alfa Laval Slide 3

History. between Consilium & Toftejorg. Toftejorg A/S. 1/1-2003 Acquired by Alfa Laval Group. www.alfalaval.com. Alfa Laval Slide 3 History Toftejorg 1953 1 st dual nozzle machine developed by Mr Tofte and Mr Jörgensen (Superintendent of Maersk) 1957 Company Tofte & Jorgensen was formed 1986 Toftejorg was formed Gunclean 1965 Seatrial

More information

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances. Residential Decks Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org

More information

2001/069. Decks, stairways,gangways and their associated handrails OFFSHORE TECHNOLOGY REPORT HSE

2001/069. Decks, stairways,gangways and their associated handrails OFFSHORE TECHNOLOGY REPORT HSE HSE Health & Safety Executive Decks, stairways,gangways and their associated handrails Prepared by Bomel Ltd for the Health and Safety Executive OFFSHORE TECHNOLOGY REPORT 2001/069 HSE Health & Safety

More information

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE TECHNICAL SPECIFICATION PART 8000 - PRECAST CONCRETE TABLE OF CONTENTS Item Number Page 8100 PRECAST CONCRETE CONSTRUCTION - GENERAL 8-3 8101 General

More information

Loads Tools Checks Reports

Loads Tools Checks Reports Loads Tools Checks Reports SDC Verifier or the Structural Design Code Verifier is a powerful postprocessor program with an advanced calculation core which works seamlessly with Siemens multi-solver, FEA

More information

Horizontal Mini Blinds Installation Guide

Horizontal Mini Blinds Installation Guide Horizontal Mini Blinds Installation Guide We make it easy! BTG 468298 EN_ rev0614 For more safety information: 1-866-662-0666 or.www.healthcanada.gc.ca/blindcords Before starting Your new Blinds To Go

More information

CONTE NT DESIGN PROCESS. Appendix. 01 First Issue. 02 Revision A. 03 Revision B. 04 Co-ordination. 05 Panel Thicknesses. 06 Panel Surface Quality

CONTE NT DESIGN PROCESS. Appendix. 01 First Issue. 02 Revision A. 03 Revision B. 04 Co-ordination. 05 Panel Thicknesses. 06 Panel Surface Quality CONTE NT DESIGN PROCESS First Issue 02 Revision A 03 Revision B 04 Co-ordination 05 Panel Thicknesses 06 Panel Surface Quality 07 CNC Timber Processing 08 Panel Standard Sizes 09 Glulam Standard Sizes

More information

Ceiling Mounted Folding Attic Ladders Installation Instructions

Ceiling Mounted Folding Attic Ladders Installation Instructions Ceiling Mounted Folding Attic Ladders Installation Instructions WARNING Before you start installing your new Louisville Ceiling Mounted Folding Attic Ladder, you must read and understand the following:

More information

UNDERGROUND ELECTRIC TEMPORARY SERVICE PANEL

UNDERGROUND ELECTRIC TEMPORARY SERVICE PANEL S 1.0 INDEX 1.0 INDEX 2.0 PURPOSE 3.0 CUSTOMER RESPONSIBILITY FOR TOTAL TEMPORARY SERVICE 4.0 CUSTOMER RESPONSIBILITY FOR TEMPORARY SERVICE IN PERMANENT LOCATION 5.0 NVE RESPONSIBILITIES 6.0 GROUNDING

More information

SHIPWORKS SHIPWORKS. www.althima.com

SHIPWORKS SHIPWORKS. www.althima.com ShipWorks allows users to design and prepare to production 100% of: ship structure, hull s sheet metal plates, mechanical parts, tubing and deck equipment. SHIPWORKS ShipWorks is based upon a new technology

More information

AIRPORT LOGISTICS SOLUTIONS FOR AIRPORT LOGISTICS. Air Cargo Terminal Equipment

AIRPORT LOGISTICS SOLUTIONS FOR AIRPORT LOGISTICS. Air Cargo Terminal Equipment AIRPORT LOGISTICS SOLUTIONS FOR AIRPORT LOGISTICS Air Cargo Terminal Equipment WWW.LODIGE.COM AIRPORT LOGISTICS OVERVIEW TERMINAL EQUIPMENT AIRPORT LOGISTICS OVERVIEW TERMINAL EQUIPMENT ROLLER CONVEYORS

More information

Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows

Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows Viewed from the exterior. IMPORTANT: Please read before you begin installation. TABLE OF CONTENTS AND TOOL / MATERIAL

More information

Technical Information

Technical Information Technical Information This section of the catalogue provides technical information that will help specify, install and maintain Surelock McGill devices and components. The topics are listed below: Blast

More information

HMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES

HMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES HOLLOW METAL MANUAL NAAMM STANDARD HMMA 810-87 8d METAL DOORS & FRAMES NAAMM 2 87 HOLLOW METAL HOLLOW METAL DOORS FOURTH EDITION NAAMM 2 87 8d METAL DOORS & FRAMES A Division of NATIONAL ASSOCIATION OF

More information

Electrical Wiring Technical Bulletin

Electrical Wiring Technical Bulletin Electrical Wiring Technical Bulletin Overview In general, SIP construction is easier and more cost effective when things are planned and thought out before the panels are manufactured. This process will

More information

EXTeRUS. EXTeRUS - With patented design, able to join technology. and quality of materials with a charming shape. Unique

EXTeRUS. EXTeRUS - With patented design, able to join technology. and quality of materials with a charming shape. Unique EXTeR US G L A S S - With patented design, able to join technology and quality of materials with a charming shape. Unique thanks to its outstanding loading capability with 150 kg maximum weight and height

More information

OSHA GUIDANCE DOCUMENT FALL PROTECTION IN RESIDENTIAL CONSTRUCTION

OSHA GUIDANCE DOCUMENT FALL PROTECTION IN RESIDENTIAL CONSTRUCTION OSHA GUIDANCE DOCUMENT FALL PROTECTION IN RESIDENTIAL CONSTRUCTION OSHA GUIDANCE DOCUMENT FALL PROTECTION IN RESIDENTIAL CONSTRUCTION Table of Contents Executive Summary... 1 Introduction... 1 Installing

More information

Safety. Fire Resistant. Gas Cylinder

Safety. Fire Resistant. Gas Cylinder All Cabinets Ship Flyer CAB09...Many in 48 hrs. Heavy Duty All Welded CABINETS 31 Models Safety Fire Resistant Spill Containment Gas Cylinder Made in USA Distributed By: Our Quality Serves You Longer JAMCO

More information

SL30-ISO PROFILE SYSTEM

SL30-ISO PROFILE SYSTEM AESTHETICS AND sustainability SL30-ISO PROFILE SYSTEM TECHNICAL DOCuMENTATION WWW.MHB.NL SL30-ISO PROFILE SYSTEM 1. SL30-ISO and SL30-ISO-PLUS Sustainability is getting worldwide more and more the attention

More information