BU Drinking water solution. BUSINESS DIVISION DRINKING WATER SOLUTIONS compact and high-performance products for the heating of drinking water

Size: px
Start display at page:

Download "BU Drinking water solution. BUSINESS DIVISION DRINKING WATER SOLUTIONS compact and high-performance products for the heating of drinking water"

Transcription

1 BU Drinking water solution BUSINESS DIVISION DRINKING WATER SOLUTIONS compact and high-performance products for the heating of drinking water

2 TAKING THE LEAD. NOW. Member of SCAN ME Legal notice: aqotec GmbH Vöcklatal 35, 4890 Weißenkirchen im Attergau, Österreich Telefon: , Fax: Reprints or reproduction, even extracts, only with permission from aqotec GmbH, 4890 Weissenkirchen, Austria. Subject to technical changes and errors. Included performance diagrams, statements and tables are exclusively to facilitate understanding. They have no bearing on our complete and current product portfolio and thus do not form a basis for planning. The images used as examples sometimes include special custom equipment. The manufacturer and type of components shown may vary. This document does not contain any catalogue goods. The units are partially planned, designed and manufactured according to customer specifications. A short waiting time must be expected. Photos: aqotec gmbh; fotalia.com

3 MADE IN AUSTRIA Water - Our most valuable food Drinking water is water for human needs. Drinking water is the most important food, it can not be replaced (input and guideline of DIN 2000). Exactly this principle stands for the development and production of drinking water solutions of aqotec. Uncompromisingly the best and most proven components are used to heat drinking water qualitatively. Hot water is now taken for granted that facilitate our daily lives. Version 01/16 - Subject to changes and errors - aqotec GmbH

4 aqopfm powerful and economical. Advantages No heat loss compared to hot water tanks High drinking water hygiene thanks to the flow principle Economic district heating network operation due to low return line temperatures Instant hot water withdrawal Exact control of hot water temperature Silent operation Connection-ready The powerful aqopfm water heaters are designed for the generation of large quantities of hot water. The hot water is heated in the continuous flow mode. By using responsive regulator valves, large differential pressures are reduced, among other things, and very low network return flow temperatures are achieved. With optional heat transfer performance, the aqopfm is suitable for use in single and multi-family homes. The aqopfm is a very economical replacement for especially infrequently used warm water tanks with high standby losses, such as those used in schools and other public buildings. aqopfm Possible heat sources Local heating network Gas, oil or wood boiler decoupled thermal energy from energy processes

5 aqopfm / PFM+ Tap output 40 C Tap output 55 C Temperature range primary 30l/min 20l/min C Warm water output 55 C Operating pressure primary max. Operating pressure cold water max. Heat exchanger Elektrical Connection Measures (WxHxD) Weight Heat meter adaptor Dirt trap mesh size 16bar / 25bar 10bar* copper soldered stainless steel 230V / 50Hz 730mm x 1300mm x 330mm ca. 35 kg 110mm DN15 0,5 mm Connections Primary 1 Hot / Cold water 1 Circulation 3/4 Approved based on Pressure Equipment Directive PED 97/23/EC *Safety valve aqopfm+ aqopfm primary aqoclick Key Circ.* secondary 1 Control cabinet+regulation 2 Temperature sensor 3 Outdoor temperature sensor 4 Return valve 5 Plate heat exchanger 6 Volumetric flow controller 7 Actuator 8 Thermal energy meter 9 Safety valve 10 Strainer 11 Thermometer 12 Emptying/Vent 14 Safety temperatur monitor/-limiter 16 Ball valve 17 Controlled amount of water (line regulator valve) 18 Circulation pump 21 Rinsing connection 40 Threaded connection 42 Water mixer (anti-scald) 43 Weld-on end 44 Flow sensor *Optional CW HW

6 aqofwss systematic and comfortable Your advantages Perfect use of space and optics No legionella formation Quick, easy installation and commissioning No pipework Protection against heat-induced calcification Optimum thermal insulation The aqotec fresh water system tank "aqofwss is the hydraulic heating plant overall solution. In a perfectly matched system, the heat source independent stratified buffer operation, the patented hygienic warm water preparation (with or without circulation) and the operation of high and low temperature heat circuits operate independently. Through the integrated tube heat exchanger, which is insensitive due to its smooth surface, aqotec guarantees a high transfer performance. In order to achieve an optimal thermal insulation, radial soft foam rings and at the pipe openings, PU foam rings are installed on the fresh water system tank. The ready to plug-in heating circuit group - HCG - and the automatic system ventilation round out the "convenience feeling" one has with aqotec products. Technical data aqofwss Connection options Wood gasifier Heat pump Wood chips Oil Pellets Gas Logs Solar Description 1000 litres Diameter 960 mm Uninsulated diameter 790 mm Insulated height 2090 mm Uninsulated height 1985 Isolated tilted height 2145 mm uninsulated tilted height 2015 Weight 178 kg permissible operating pressure 3 bar perm. operating temperature heating 95 C perm. operating temperature solar 110 C circuit Solar heating surface register 3 m³ Content solar heat exchangers 8.8 l Sensor sleeve (n) Ø 15 x 200 mm FWW sensor sleeve 450 mm Heating sensor sleeve FH mm Heating sensor sleeve FH mm Heating sensor Solar FS 480 mm

7 aqofws fresh.quick.reliable. Advantages Smallest possible block construction Installation directly on the buffer or the wall Low-maintenance design No wearing parts Impressive design Optimum thermal insulation High withdrawal amount No installation costs for drainage No water and energy loss Using patented temperature control, the fresh water station "aqofwss", in combination with the fresh water system tank "aqofws", guarantees a permanent, vigorous supply of fresh hot water with no waiting time or temperature fluctuations. The thermally insulated fresh water station can supply up to three families. With the large, copper soldered plate heat exchanger, it is possible to obtain up to 30 litres per minute (45 C). aqofws Width 400 mm Height 800 mm Depth 330 mm Insulation EPP black Tap power 30l/min. Weight 20 kg min. permissible operating temperature 2 C max. permissible operating temperature 95 C min. permissible operating pressure Domestic water 10 bar Heating side 3 bar Load pump: Voltage 230V / 50Hz Rotation speed 200 R/min. Power consumption 93 W Nominal power 0.4 A Circulation pump (optional) Voltage 230V/ 50 Hz Rotational speed level 1 Power consumption 8 W Nominal power A Tip Circulation set: Circulation set The hot water circulation set is used to expand the FWS30 with a circulation pump to increase the flow of hot water and has a timer mode as well as a pulse mode. An integrated automatic return line thermostat and a gravity brake offer even more comfort. The perfectly designed push-in solution allows for quick installation. perfectly insulated clearly designed

8 aqoblm efficiency for upgrading. Advantages Compact method of construction Plate heat exchanger with maximum thermal length for low return flow temperatures Damping of the inlet and outlet flow rates Cold water and accumulator charging circuit return integration at the lowest point easily retrofitted The standard model "aqoblm" is a compact boiler load module solution for retrofitting to an existing aqoclick district heating station. The module in its basic version can be extended with an additional mixer heating circuit. The controller integrated into the aqoclick takes over control of the heating circuit module. It collects all the information from the sensors and controls pumps and valves. If no heat is required, the corresponding components are switched off. aqoblm + aqoclick aqoblm+ Key primary secondary HW 1 Control cabinet+regulation 2 Temperature sensor 3 Outdoor temperature sensor 4 Return valve 5 Plate heat exchanger 6 Volumetric flow controller 7 Actuator 8 Thermal energy meter 9 Safety valve 10 Strainer 11 Thermometer 14 Safety temperature monitor/-limiter 16 Ball valve 17 Controlled amount of water (line regulator valve) 18 Circulation pump 21 Rinsing connection 24 3-way mixing valve 40 Threaded connection *Optional CW secondary Circ.*

9 aqoblm+ compact and progressive The compact district heating transfer station with integrated DWH "agoblm" can be connected to the district heating networks and boiler systems. The system is, due to its low return temperature, especially suitable for district heating connections, flue gas condensation or power stations with combined heat and power. Simply connected to the district heating station, the aqoclick module is ready to use. From a drinking water perspective, the system is suitable for all kinds of demand. Through the relationship between continuous power and peak power, the different requirements can be addressed. For systems with DDC control, a regular legionella control to kill bacteria is programmed into the hot water pipe network. primary HW Circ.* secondary HW CW Key 1 Control cabinet+regulation 2 Temperature sensor 3 Outdoor temperature sensor 4 Return valve 5 Plate heat exchanger 6 Volumetric flow controller 7 Actuator 8 Thermal energy meter 9 Safety valve 10 Strainer 11 Thermometer 14 Safety temperature monitor/-limiter 16 Ball valve 17 Controlled amount of water (line regulator valve) 18 Circulation pump 21 Rinsing connection 32 DHW cylinder 40 Threaded connection 43 Welding ends *Optional aqosblm

10 aqostore BLMdirect perfect solution - minimal effort Advantages Efficient storage with direct solar charging module combines a total solution various power versions Time-consuming assembly on site eliminated by All-In-One Solution Optimum thermal insulation Fast, easy set-up Protection against heat-related calcification aqohkg incredibly powerful. Advantages Smallest possible block construction minimal installation effort Maintenance without buffer and heating emptying Ball valves with flow and return line display (optional) great performance with mixer with high kvs-value* = 4.0 suitable for all different heating controls Integrated gravity brake ensures no incorrect circulation The heating circuit groups for low and/or high temperature circuits are mounted, like the other components, directly to the buffer tank and extract for floor heating or radiators the required hot water from the heating zone of the buffer tanks and layer the return lines in the appropriate buffer zone. The heating circuit module is used to connect high temperature and/or low temperature heating circuits to the FWSS system memory. It has an adjustable constant return line mixture and is suitable for circulation pumps with front-side terminals. A thermal insulation made of EPP and an optimised buffer connection ensure minimal heat loss of the heating circuit module.

11 CONTROL TECHNOLOGY Intuitive tools for network and special station controls for best heat operation SMALL AND LARGE UNITS compact district heating transfer stations, individually designed to meet customer requirements HOME STATIONS sophisticated and user-friendly solutions to transfer heat and water PLANNING & ENGINEERING Solutions for heat generation - from the idea right through to commissioning CONTROL AND COMMUNICATION TECHNOLOGY perfect energy management from the point of power generation to the billing of heat customers ENERGY MANAGEMENT AND AUDIT Total solutions for the optimisation of heat distribution and supply DHW SOLUTIONS compact, high-performance solutions for DHW heating SPECIAL PLANT ENGINEERING Heat solutions perfectly matched according to the wishes of the customer

12 Austria aqotec GmbH Vöcklatal Weißenkirchen i. Attg. South Tyrol aqotec GmbH Klosterweg Welsberg (BZ) Czech Republic aqotec s.r.o. U Sladovny Hodonice France aqotec France 8, rue du Rempart Colmar Germany aqotec Consulting GmbH Otto-Hahn-Straße 13b Riemerling/Ottobrunn Poland aqotec Polska Sp. z o.o. ul. Urzędnicza 26 lok Kraków Italy aqotec Italia s.r.l. via della Mendola Bolzano T F T T F T T F T T T

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation) PRO-CLEAN Product description Specifications Technical Description Max. backup operating pressure Max. service water operating pressure 3 bar 6 bar Hot water connection " female thread* V4A (no..4) Cold

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25 PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions Domestic hot water modules:

More information

Create the right atmosphere with renewables.

Create the right atmosphere with renewables. The complete ROTEX heat pump product range Create the right atmosphere with renewables. ROTEX air-to-water and ground source heat pumps for new build and modernisation. The inexhaustible heat source on

More information

ROTEX Solaris: Use the energy of the sun. ROTEX Solaris Solar energy for hot water and heating. The heating!

ROTEX Solaris: Use the energy of the sun. ROTEX Solaris Solar energy for hot water and heating. The heating! ROTEX Solaris: Use the energy of the sun. ROTEX Solaris Solar energy for hot water and heating. The heating! Solar energy: free and inexhaustible. Energy and resources The solar age has begun. Low expenditure

More information

ECOplus Solar Cylinder

ECOplus Solar Cylinder TECHNICAL INFORMATION Solar Cylinder Wagner& Co Connection Options for CONVECTROL II The Effective Convection Brake Technically and fluidically optimized barriers separate the water cooled in the pipes

More information

Natural geothermal energy.

Natural geothermal energy. ROTEX ground source heat pump Natural geothermal energy. ROTEX HPU ground the ground source heat pump that heats with free geothermal energy. Compact, environmentally responsible and uniquely efficient.

More information

SOLAR HEATING SYSTEMS. www.orkli.com

SOLAR HEATING SYSTEMS. www.orkli.com SOLAR HEATING SYSTEMS www.orkli.com // 2 Orkli is one of the main European manufacturers of components for household appliances and innovative solutions for the comfort sector. Its corporate activity is

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

30% Safe. DESIGN GUIDE The Danfoss EvoFlat system from A-Z Take lead on your project with an efficient system concept. evoflat.danfoss.

30% Safe. DESIGN GUIDE The Danfoss EvoFlat system from A-Z Take lead on your project with an efficient system concept. evoflat.danfoss. MAKING MODERN LIVING POSSIBLE DESIGN GUIDE The Danfoss EvoFlat system from A-Z Take lead on your project with an efficient system concept Safe and comfortable EvoFlat systems provide heating and domestic

More information

building engineering services association specification for: Domestic Heating www.thebesa.com

building engineering services association specification for: Domestic Heating www.thebesa.com building engineering services association specification for: Domestic central Heating installation www.thebesa.com building engineering services association acknowledgments Guide to good practice: Domestic

More information

Solar Hot Water Heaters

Solar Hot Water Heaters Solar Hot Water Heaters Three High Vacuum Water inlet Stainless Steel screw Gel seal and insulation Water outlet Dust proof seals Non Pressure Models Details ASWH-1b ( Color Painted 304 ) ASWH-1c ( stainless

More information

Solar Combisystems Changes on the market place since Task beginning

Solar Combisystems Changes on the market place since Task beginning Solar Combisystems Changes on the market place since Task beginning A Report of IEA SHC - Task 26 Solar Combisystems February 2003 Jean-Marc Suter Solar Combisystems Changes on the market place since Task

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-A Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs

More information

Electric Flow Boiler

Electric Flow Boiler Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler

More information

Smile. The All-In-One Heating Controller

Smile. The All-In-One Heating Controller Smile EVERYTHING UNDER CONTROL The All-In-One Heating Controller Versatile, energy-efficient heating control. The All-In-One Heating Controller Smile controllers are ideal to gain maximum efficiency from

More information

ROTEX gas hybrid heat pump. A strong team.

ROTEX gas hybrid heat pump. A strong team. ROTEX gas hybrid heat pump A strong team. The new ROTEX HPU hybrid gas hybrid heat pump always selects the most favourable heating mode automatically. For a long time the general opinion was that a heat

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Visions become real. Temperature control and cooling systems. The innovative and reliable solution Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.

More information

High-efficient gas boiler CompactGas

High-efficient gas boiler CompactGas High-efficient gas boiler CompactGas Patented alufer for a high efficiency and low emission. 1 CompactGas (1000-2800). Advantages at a glance. The Hoval CompactGas fulfils all expectations with regard

More information

DIETRISOL SOLAR WATER HEATING SYSTEMS ENERGY SAVINGS AND ECOLOGICAL BENEFITS SUSTAINED COMFORT SIMPLICITY AND RELIABILITY INNOVATIVE, MODULAR SYSTEMS

DIETRISOL SOLAR WATER HEATING SYSTEMS ENERGY SAVINGS AND ECOLOGICAL BENEFITS SUSTAINED COMFORT SIMPLICITY AND RELIABILITY INNOVATIVE, MODULAR SYSTEMS DIETRISOL SOLAR WATER HEATING SYSTEMS ENERGY SAVINGS AND ECOLOGICAL BENEFITS SUSTAINED COMFORT SIMPLICITY AND RELIABILITY INNOVATIVE, MODULAR SYSTEMS DIETRISOL SOLAR WATER HEATING SYSTEMS NON-POLLUTING,

More information

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

Range Tribune HE Solar Unvented Direct and Indirect Cylinders Range Tribune HE Solar Unvented Direct and Indirect Cylinders Range Tribune HE Solar cylinders have been designed specifically with Solar applications in mind and are based on the highly successful Range

More information

HEAT INTERFACE UNITS (Modular)

HEAT INTERFACE UNITS (Modular) HEAT INTERFACE UNITS The Rhico T Fire Modular is probably the most versatile HIU available, the basic unit is a indirect heating only module incorporating a circulation pump on the secondary circuit. (A

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Price List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza 50.006 (Spain) Tel.: 976302135 Fax: 976468085 www.aguidrovert.com info@aguidrovert.

Price List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza 50.006 (Spain) Tel.: 976302135 Fax: 976468085 www.aguidrovert.com info@aguidrovert. Price List Rev.2 2010 AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza 50.006 (Spain) Tel.: 976302135 Fax: 976468085 www.aguidrovert.com info@aguidrovert.com SOMMARIO INDEX SOLAR SYSTEMS... page 10 COMPONENTS

More information

Stove-boiler for solid fuels 12-30 KW Directions for use and assembling

Stove-boiler for solid fuels 12-30 KW Directions for use and assembling Stove-boiler for solid fuels 12-30 KW Directions for use and assembling February 7, 2012 Contents 1 Technical data 2 1.1 Boiler properties TEMY PLUS 12-30 KW......................... 3 1.2 On Product............................................

More information

HYBRID HEAT PUMPS. Switch over to more efficiency, even in old buildings. Air/water system for heating HBW series. Quality with systems. max.

HYBRID HEAT PUMPS. Switch over to more efficiency, even in old buildings. Air/water system for heating HBW series. Quality with systems. max. HYBRID HEAT PUMPS Switch over to more efficiency, even in old buildings max. 90 Inlet temperature Air/water system for heating HBW series 1-2015 Quality with systems THE HYBRID TREND TECHNOLOGY Two technologies

More information

Description of functions

Description of functions Description of functions Laddomat 21 is designed to......allow the boiler to reach a high working temperature soon after firing....to preheat the cold tank water in the bottom of the boiler so that the

More information

Itho Products for Hot and Boiling water. product-

Itho Products for Hot and Boiling water. product- Itho Products for Hot and Boiling water product- 2 This booklet provides additional information on the range of hot and boiling water appliances by Itho. The data will allow you to determine which product

More information

HEAVY DUTY STORAGE GAS

HEAVY DUTY STORAGE GAS Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many

More information

Power consumption (kw)

Power consumption (kw) OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components

More information

HOT WATER SYSTEMS. www.thermann.com.au

HOT WATER SYSTEMS. www.thermann.com.au HOT WTER SYSTEMS www.thermann.com.au GS HOT WTER SYSTEM The Thermann 4 star Gas hot water heater can suit almost any family type. With an adjustable thermostat for safety and efficiency it allows you to

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

FIELD TESTS OF FUEL EFFICIENCY MAGNETS J A CRABB JULY 1997 SWEEG REPORT 80

FIELD TESTS OF FUEL EFFICIENCY MAGNETS J A CRABB JULY 1997 SWEEG REPORT 80 FIELD TESTS OF FUEL EFFICIENCY MAGNETS J A CRABB JULY 1997 SWEEG REPORT 80 List of symbols T f average temperature at the flow header, C T r average temperature at the return header, C f average water

More information

Vitocaldens 222-F Compact Gas-Hybrid appliance

Vitocaldens 222-F Compact Gas-Hybrid appliance Vitocaldens 222-F Compact Gas-Hybrid appliance Heating systems Industrial systems Refrigeration systems 2/3 Vitocaldens 222-F: The future-proof energy-source mix in one appliance Choosing Vitocaldens

More information

Laddomat 21-60 Charging unit

Laddomat 21-60 Charging unit Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the

More information

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International ASPE Seminar Water Heater Piping Strategies Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International Presentation Overview Water Heater Piping Strategies How to size a water heater?

More information

Technical Data Manual Model Nos. and pricing: see Price List

Technical Data Manual Model Nos. and pricing: see Price List VITOCELL-V 00 Indirect-fired domestic hot water storage tank 4 to 0 / 60 to Technical Data Manual Model Nos. and pricing: see Price List Vitocell-V 00 4 to / 60 to Vitocell-V 00 0 / Vitocell-V 00 CVA Series

More information

Versati Air to Water Heat Pump

Versati Air to Water Heat Pump Versati Air to Water Heat Pump VERSATI DC Inverter Multifunctional Air To Water Heat Pump Nowadays, people are increasingly focusing on heating costs as well as environmental issues. Traditional heating

More information

ELECTRIC CENTRAL HEATING FLOW BOILER

ELECTRIC CENTRAL HEATING FLOW BOILER ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment

More information

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT MAXIMATOR GmbH 2 MAXIMATOR has an extensive know-how concerning concept, development, construction and manufacturing of test benches and

More information

Homeowner Quick Start Guide. Version 2

Homeowner Quick Start Guide. Version 2 Homeowner Quick Start Guide Version 2 Introduction to Your New Mitsubishi Electric Ecodan Heating System This booklet has been created to enable you to quickly personalise the Heating System controls

More information

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Ergo-Pro Single Line Solar Station Installation and Operating Instructions Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating

More information

Link-Up. Solid Fuel Association Guide to Central Heating. www.solidfuel.co.uk

Link-Up. Solid Fuel Association Guide to Central Heating. www.solidfuel.co.uk Solid Fuel Association Guide to Central Heating Link-Up Combining solid fuel with other central heating technologies using various methods ranging from a simple link-up to a fully integrated thermal store

More information

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None 1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements

More information

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease The NEW Greenstar i innovative intuitive improved performance installation ease A NEW look, NEW features and a NEW NAME for the UK s best selling boiler, the Greenstar i Junior 1 Introducing the new Greenstar

More information

Air Source Heat Pump Installation and Maintenance Manual

Air Source Heat Pump Installation and Maintenance Manual Air Source Heat Pump Installation and Maintenance Manual Model Numbers: RC090MHXEA RC160MHXEA January 2013 www.samsungehs.co.uk Hendra - January 2013 1 The outdoor unit (boiler) Deciding on Where to Install

More information

www.the Floor Heating Warehouse.co.uk

www.the Floor Heating Warehouse.co.uk www.the Floor Heating Warehouse.co.uk Underfloor Heating Installation Guide (Grundfoss Pump System) General Overview: Our water based underfloor heating system can be installed by your own plumber or heating

More information

Instructions for designing heating systems.

Instructions for designing heating systems. Instructions for designing heating systems. In order to obtain the required effect, a lower consumption, a smaller quantity of impurities and improved comfort, heat and domestic hot water installations

More information

Hot water supply, distribution and use

Hot water supply, distribution and use Guidance Leaflet Reducing use Hot supply, distribution and use All businesses use hot in some way, whether for domestic use, in the manufacturing process or for ancillary activities. As there are considerable

More information

Mounting and operating instructions. Fresh water station WHI freshaqua 44 #1 Fresh water station WHI freshaqua 55 #1 83514402 1/2014-03

Mounting and operating instructions. Fresh water station WHI freshaqua 44 #1 Fresh water station WHI freshaqua 55 #1 83514402 1/2014-03 Mounting and operating instructions Fresh water station WHI freshaqua 44 #1 Fresh water station WHI freshaqua 55 #1 83514402 1/2014-03 1 Information for the user... 5 1.1 User guidance... 5 1.1.1 Symbols...

More information

Material test chamber with mechanical convection

Material test chamber with mechanical convection FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and

More information

Energy Efficiency HOSPITALITY. www.energia.ie

Energy Efficiency HOSPITALITY. www.energia.ie Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real

More information

MADE IN GERMANY. Valves, controls + systems Thermal solar energy Stations, controllers, collectors, accessories, service, software

MADE IN GERMANY. Valves, controls + systems Thermal solar energy Stations, controllers, collectors, accessories, service, software Innovation + Quality Valves, controls + systems Thermal solar energy Stations, controllers, collectors, accessories, service, software Product range Award: MADE IN GERMANY Thermal solar energy Content

More information

PE1 Pellet. PE1 Pellet. Pellet boiler. PE1 Pellet. www.froeling.com

PE1 Pellet. PE1 Pellet. Pellet boiler. PE1 Pellet. www.froeling.com PE1 Pellet PE1 Pellet Pellet boiler PE1 Pellet www.froeling.com 1 Heating with pellets For more than 50 years Froling has specialised in the efficient use of wood as a source of energy. Today the name

More information

Heat Recovery based on Exhaust Air

Heat Recovery based on Exhaust Air Heat Recovery based on Exhaust Air Heating Domestic Hot Water Controlled Ventilation Preheated Supply Air MADE IN SWEDEN VENTILATION HEALTH ASPECTS Ventilation, which means totally hygienic inside air,

More information

KONRAD. Hybrid Fancoil Series

KONRAD. Hybrid Fancoil Series KONRAD Hybrid Fancoil Series Konrad is an innovative radiator which cools you down and warms you up. Indeed, it cools in summer and heats in winter; but it makes it with an incomparable quietness. Thanks

More information

Session 2: Hot Water Supply

Session 2: Hot Water Supply MEBS6000 Utility Services http://www.hku.hk/mech/msc-courses/mebs6000/index.html Session 2: Hot Water Supply Dr. Benjamin P.L. Ho Department of Mechanical Engineering The University of Hong Kong E-mail:

More information

LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure.

LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure. LMS The modular management system for condensing boilers Control Products & Systems OEM Answers for infrastructure. LMS advanced electronics and proven software At times of dwindling resources, rising

More information

YUTAKI S. Domestic Heating

YUTAKI S. Domestic Heating YUTAKI S ECOLOGY & COMFORT OUTDOOR UNIT RAS 3HVRNME-AF YUTAKI-S MODULE RWM 2~10.0HFSN3E The Yutaki S heat pump is the ideal solution both in new installations and refurbishments. Its exceptional performance

More information

Thermo Siphon Solar Systems

Thermo Siphon Solar Systems Thermo Siphon Solar Systems Thermo Siphon Solar Systems are a very cost effective way of producing hot water due to their simplicity in design and installation requirements. Usually more common in hotter

More information

Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669

Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669 Report Date: 04/03/2014 Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669 About this Advisory Report Energy use in our homes is responsible for almost

More information

8 716 473 216-00.3O. Gas boiler. Gaz 6000 W WBN 6000-30-H-E-N/L-S2400. Operating instructions for the end customer. 8 716 473 217 (2014/07) en

8 716 473 216-00.3O. Gas boiler. Gaz 6000 W WBN 6000-30-H-E-N/L-S2400. Operating instructions for the end customer. 8 716 473 217 (2014/07) en 8 716 473 216-00.3O Gas boiler WBN 6000-30-H-E-N/L-S2400 Operating instructions for the end customer en 2 Contents Contents 1 Key to symbols and safety instructions................... 2 1.1 Key to symbols..................................

More information

Sizing and Selection of Hot Water Generating Plant. Presentation by: Rob Larner & David Dutch

Sizing and Selection of Hot Water Generating Plant. Presentation by: Rob Larner & David Dutch Sizing and Selection of Hot Water Generating Plant Presentation by: Rob Larner & David Dutch SIZING HOT WATER PLANT - agenda Consider different sizing methods. Arrive at a design example for a 200 bed

More information

STOVE-BOILER FOR SOLID FUELS Directions for use and assembling

STOVE-BOILER FOR SOLID FUELS Directions for use and assembling STOVE-BOILER FOR SOLID FUELS Directions for use and assembling Sadrºaj 1 Technical data 2 1.1 Boiler properties TEMY PLUS P 25............................. 3 1.2 On Product............................................

More information

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A Technical Data Manual Model Nos. and pricing: see Price List Vacuum tube collector based on the heat pipe principle For the utilisation of solar energy VITOSOL r 200-T SP2A Product may not be exactly as

More information

Automatic control equipment for HVAC systems

Automatic control equipment for HVAC systems Automatic control equipment for HVAC systems Products for domestic and industrial installations In buildings, the main aim of the installations is to guarantee and maintain a comfortable ambient. Watts

More information

ErP made easy! Valves, controls + systems. Guideline Individual packages according to ErP with high energy efficiency and a good benefit/cost ratio

ErP made easy! Valves, controls + systems. Guideline Individual packages according to ErP with high energy efficiency and a good benefit/cost ratio Valves, controls + systems Innovation + Quality Guideline Individual packages according to ErP with high energy efficiency and a good benefit/cost ratio ErP made easy! ErP Directive Content ErP Directive

More information

VDL 53 - Vacuum drying oven for flammable solvents

VDL 53 - Vacuum drying oven for flammable solvents Vacuum drying ovens VDL 53 - Vacuum drying oven for flammable solvents The VDL series ensures maximum safety when drying organic solvents in accordance with TÜV/GS guidelines. The interior chamber is designed

More information

Daikin Altherma hybrid heat pump. The natural combination

Daikin Altherma hybrid heat pump. The natural combination Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Why choose Daikin Altherma hybrid heat pump? What the customer wants: more energy efficient

More information

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II 1 For your safety Table of Contents 1 For your safety... 3 1.1 About this manual... 3 1.2 Designated use... 3 1.3 Qualification

More information

Program Summary. Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement

Program Summary. Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement Program Summary Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement 2 Table of content Content Fluid & Motion Control 3 Directional Control Valves, solenoid operated 4 Directional

More information

COMMERCIAL REPORT / STOCK CONDITION SURVEY. Sydenham Hill Estate Sydenham Hill London SE 23

COMMERCIAL REPORT / STOCK CONDITION SURVEY. Sydenham Hill Estate Sydenham Hill London SE 23 COMMERCIAL REPORT / STOCK CONDITION SURVEY For Sydenham Hill Estate Sydenham Hill London SE 23 Submission Prepared by Gas Advisory Services Limited Date: 4 th June 2013 Gas Advisory Services Limited Phoenix

More information

main heating: pre1998 ducted warm air system main heating fuel: mains gas main heating SAP efficiency: 70.0% main heating controls: programmer

main heating: pre1998 ducted warm air system main heating fuel: mains gas main heating SAP efficiency: 70.0% main heating controls: programmer Archetype: 3250330 Archetype Description: 1965-1975, semi / end terraced dwelling, timber frame walls, oil / gas / electric warm air heating, E This archetype represents 823 dwellings, which accounts for

More information

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4 Henco Snelselectie kaart EN IMPORTANT! Before starting work the fitter must carefully read this installation and operation manual, understand and observe its conditions. The water floor heating control

More information

WC flushing cistern single or dual flush 0.13 0.05 2 to fill in 2 minutes WC trough cistern 0.15 per WC 0.10 2 Wash basin tap size 1 2

WC flushing cistern single or dual flush 0.13 0.05 2 to fill in 2 minutes WC trough cistern 0.15 per WC 0.10 2 Wash basin tap size 1 2 HAC_C0.qxd 7/4/08 9: Page 74 Chapter Pipe sizing Pipes and fittings should be sized so that the flow rates for individual draw-offs are equal to the design flow rates shown in table.. During simultaneous

More information

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety

More information

Daikin Altherma Hybrid Heat Pump

Daikin Altherma Hybrid Heat Pump your comfort. our world. Daikin Altherma Hybrid Heat Pump Smart heating technology for the best of both worlds Heating Integrated Solutions Ventilation Air Conditioning Refrigeration Forward thinking About

More information

Energy Saving Fact Sheet Boilers

Energy Saving Fact Sheet Boilers Energy Saving Fact Sheet Boilers Turn a burning issue into real energy savings You need a boiler to heat your premises and provide hot water or to generate steam for use in industrial processes. Unfortunately,

More information

Daikin Altherma Hybrid Heat Pump

Daikin Altherma Hybrid Heat Pump Daikin Altherma Hybrid Heat Pump Smart technology for the best of both worlds NATIONAL HEAT PUMP 19 JUNE 2014 ICC BIRMINGHAM WINNER Forward thinking Now is the time to rethink the way we heat our homes

More information

Automatic Back-Flushing Filter AutoFilt RF9.

Automatic Back-Flushing Filter AutoFilt RF9. Automatic Back-Flushing Filter AutoFilt RF9. AutoFilt RF9 Clearing the Way. The Challenge: In response to the Tier III standard which will come into effect in 2016, the International Maritime Organization

More information

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

TANKLESS WATER HEATER INSTALLATION DIAGRAMS TANKLESS WATER HEATER INSTALLATION DIAGRAMS Installation Diagrams Tankless Installation / Optional Return Small 10-15 Gallon Point-of-Use Water Single and Optional Return : One single, small capacity water

More information

stainless steel pre-assembled manifolds

stainless steel pre-assembled manifolds TECHNICAL CATALOGUE stainless steel pre-assembled manifolds TEC ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and

More information

www.optimumheat.co.uk

www.optimumheat.co.uk The modern wood pellet boiler with built-in flexibility and remote fingertip control Up to 98% efficient Wide output range Simple touch-panel control Remote control & maintenance Extremly low emissions

More information

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE PELLEXIA COMFORT ENVIRONMENT COMPATIBLE To valorize the pellet MODEL nominal output min/max kw global output min/max % pellet reservoir content kg PELLEXIA 7 8 7 8,8 89 50 PELLEXIA 40 3 39,7 85 90,3 50

More information

The complete heating system.

The complete heating system. ROTEX EcoHybrid The complete heating system. ROTEX EcoHybrid renewable energy sources perfectly combined. "We had no idea how complicated selecting the right heating system for our house would be. Fortunately

More information

Continuous flow direct water heating for potable hot water

Continuous flow direct water heating for potable hot water Continuous flow direct water heating for potable hot water An independently produced White Paper for Rinnai UK 2013 www.rinnaiuk.com In the 35 years since direct hot water systems entered the UK commercial

More information

HVAC Processes. Lecture 7

HVAC Processes. Lecture 7 HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump

More information

StainlessLite. Unvented mains pressure and vented water storage in Duplex stainless steel SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

StainlessLite. Unvented mains pressure and vented water storage in Duplex stainless steel SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS StainlessLite Unvented mains pressure and vented water storage in Duplex stainless steel SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS Gledhill built on service, quality and tradition The Gledhill

More information

CALEFFI. SATK wall-mounted Heat Interface Unit - HIU Instantaneous domestic hot water production. SATK20 - SATK30 series 01209/13 GB

CALEFFI. SATK wall-mounted Heat Interface Unit - HIU Instantaneous domestic hot water production. SATK20 - SATK30 series 01209/13 GB SATK wall-mounted Heat Interface Unit - HIU Instantaneous domestic hot water production SATK20 - SATK30 series ACCREDITED CALEFFI 01209/13 GB ISO 9001 FM 21654 ISO 9001 No. 0003 The latest generation heat

More information

Energy Efficiency E-module - Guidance. Efficient Operation of Low Temperature Hot Water Boilers in the Public Sector

Energy Efficiency E-module - Guidance. Efficient Operation of Low Temperature Hot Water Boilers in the Public Sector Energy Efficiency E-module - Guidance Efficient Operation of Low Temperature Hot Water Boilers in the Public Sector Efficient Operation of Low Temperature Hot Water Boilers in the Public Sector 2 Contents

More information

ABB i-bus KNX Fan Coil Controller FC/S 1.1

ABB i-bus KNX Fan Coil Controller FC/S 1.1 Product manual ABB i-bus KNX Fan Coil Controller FC/S 1.1 Intelligent Installation Systems Contents Page 1 Introduction... 2 2 Device technology... 3 3 Application and planning 3.1 Heating, ventilation

More information

Cooking at the Speed of light!

Cooking at the Speed of light! Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide

More information

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH Centauri Condensing Fire Tube Water Boiler 399 to 1000 MBH Pre-mix surface burner with up to a 7-to-1 turndown NOx levels as low a 5 ppm at full rate Operates on 4" gas pressure shown with optional gauges

More information

Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min. www.kaeser.com

Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min. www.kaeser.com Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min www.kaeser.com Made in Germany KAESER s renowned MOBILAIR range of portable compressors is

More information

Gas Condensing Boilers

Gas Condensing Boilers Gas Condensing Boilers www.johnsonandstarley.co.uk QuanTec Ultra Efficient Condensing Gas Boilers Including HR28C with Integral Passive Flue Gas Heat Recovery As market leaders and innovators, Johnson

More information