50 AZs. Packaged Rooftop/Cooling Units. Nominal cooling capacity kw. Features

Size: px
Start display at page:

Download "50 AZs. Packaged Rooftop/Cooling Units. Nominal cooling capacity kw. Features"

Transcription

1 Packaged Rooftop/Cooling Units 0036 Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. 50 AZs Nominal cooling capacity kw The 50AZ packaged rooftop units are versatile and efficient air conditioners, designed for outdoor installation. The units are self-contained and can be installed in commercial and industrial applications. Features The new refrigerant R-407C, a blend of R-32, R-125 and R-134a, offers an economical solution to environmental proteciton problems. The components of these units are specifically designed for the new refrigerant, and the units have been submitted to necessary laboratory tests to ensure perfect operation. The unit cabinet is made of powder painted sheet metal, especially suitable for outdoor use. Reduced size and weight make these units ideal for today s lightweight building structures. Models 016, 024, 028 have scroll compressors; the other sizes have reciprocating hermetic compressors. All are designed for use with R-407C and include a thermal cutout to protect the motor against overloads and over temperatures. The compressors are mounted on vibration isolators. Crankcase heaters are standard for 034, 040. Double-inlet indoor fans have forwarded-curved blades. The revolutionary, low-niose, two-speed Flying Bird II fan is made of a composite recyclable material and employs a multi-blade design and rotating shroud, as used in the aeronautical industry. It is exceptionally quiet, and does not generate the low-frequency noise, irritating the human ear. At part load or low outdoor temperatures the fan automatically switches to the low speed. The heat exchangers are made of high-quality staggered copper tubing, mechanically bonded in precoated corrugated Aluminum fins, with a high level of corrosion ad UV protection. The refrigerant circuit uses deoxidized and dehydrated copper tubes with obus type access valves. It includes a full refrigerant charge, expansion valves, and all components required for correct unit operation.

2 The units are fully wired in accordance with EN standards and include thermo magnetic circuit breakers and a main disconnect switch. All pipes and refrigeration components are welded except for the compressors which are connected via rotolock connections. Pressure sensors are mounted directly on the pipes. Electrical connections are simplified, and the standard equipment includes a main disconnect switch and a single entry point of the three-phase without neutral power supply to the whole unit. PRO-DIALOG Plus Control PRO-DIALOG Plus is an advanced numeric control system that combines complex intellegence with great operating simplicity. PRO-DIALOG Plus constantly monitors all machine parameters, optimizing the operation of compressors and fans. A powerful control system The PRO-DIALOG Plus Control is auto-adaptive and guarantees total protection of the compressors. The system permanently checks the operating parameters and responds simultaneously to avoþd excessive cycling and maintain the ideal operating range for the compressor (temperatures and pressures out of range etc.). By taking corrective action before the fault occurs, the auto-adaptive control frequently prevents a shutdown of the cooling only due to a faulty condition. To optimize power consumption, PRO-DIALOG Plus automatically resets the space temperature setpoint in accordance with the outdoor air temperature or uses a second set-point (example occupied / unoccupied). Clear and easy-to-use control system The operator interface is clear and user-friendly: LED s and two numeric displays ensure immediate verification of all unit operating data. Buttons, conveniently positioned on a synoptic cooling only diagram, offer immediate display of the operating parameters: temperatures, pressures, set point, run times etc. 10 menus offer direct access to all machine controls, including a history of possible faults, for rapid and complete cooling only fault diagnosis. Extended communications capabilities PRO-DIALOG Plus allows remote control. Voltfree contacts regulate: start/stop, power demand limit or selection of the second set point. The system permits remote signaling of any possible anomaly for each refrigerant circuit. PRO-DIALOG Plus ensures the time schedule programming of the cooling only: - start/stop, -operation at the second set point (e.g.unoccupied mode), -low-speed fan operation (e.g. during the night) -This also controls the operation up to 6 units in a master/slave assembly and offers a serial RS 485 communication port. Options and accessories Option Accessory Economizer - enthalpic Economizer - thermostatic Electric heater Crankcase heater Hot water coil with prop. valve Front discharge roof curb Vertical roof curb Adjustable longitudinal roof curb, vert. discharge Adjustable transverse roof curb, vert. discharge Air return fan Power exhaust Dirty filter alarm High-efficiency filters Additional space temperature sensor Smoke detector Economizer hood Thermostat - TSTAT with programmable Thermostat - TSTAT without programmable IAQ - Indoor air quality sensor Manual outdoor air damper Air flow detector Barometric exhaust High static pressure transmission

3 Physical data 50AZ Nominal Cooling Capacity* kw 43 54, ,1 99,5 116,1 Operating Weight kg Refrigerant charge R407C Circuit A kg 11,6 6,2 9,4 9,4 14,6 15,5 Circuit B kg 7,1 9,9 9,9 14,6 15,5 Compressor Scroll Hermetic Scroll Scroll Hermetic Hermetic Quantity, Circuit A Quantity, Circuit B Oil charge (each) l 6, ,6 7,6 7,6 Control Type PRO-DIALOG Plus Indoor Coil Copper tubes, precoated aluminium fins Face Area m² 1,71 1,71 1,71 1,71 2,56 2,56 Rows... Fin spacing (-...mm) , , , , Outdoor Coil Copper tubes, precoated aluminium fins Face Area m² 2,05 1,93 2,78 2,78 5,20 5,20 Rows... Fin spacing (-...mm) , , , , Indoor Fan Centrifugal Quantity Air Flow l/s Fan Speed r/s 15,41 18,08 16,5 16,5 13,88 14,21 Nominal power input kw 3 4 5,5 5,5 6,4 6,74 Nominal static pressure (Dry/Wet) Pa 160 / / / / / / 150 Outdoor Fan Axial Flying Bird fans with rotating shroud Quantity Air Flow l/s Fan Speed (high/low speed) r/s 15.6/ / / / / /7.8 Nominal power input (each) kw 1,8 0,75 1,8 1,8 1,8 1,8 Air Filter Washable Quantity Width x Height mm 900x x x x x x750 Thickness mm * Nominal Eurovent conditions outdoor air dry bulb temperature of 35 o C, indoor air wet bulb temperature of 19 o C Electrical data (3 ph, 50Hz) 50AZ Nominal Supply - 50Hz - 3 phase V 400 Voltage Range V Min. 360 Max. 440 Nominal power input* kw 17,49 27,08 31,85 37,11 45,70 54,10 Effective power input* kw 16,14 25,16 29,85 34,74 42,37 50,81 Nominal Current drawn* A 36,30 49,33 56,23 67,77 79,70 92,80 Effective Current drawn* A 33,50 45,84 52,70 63,45 73,90 87,15 Maximum power input** kw 20,63 30,07 37,56 44,39 50,75 60,10 Maximum current drawn** A 42,78 54,75 66,29 81,06 88,50 103,10 Starting current A , * Nominal Eurovent conditions outdoor air dry bulb temperature of 35 o C, indoor air w et bulb temperature of 19 o C ** Based on an outdoor air dry bulb temperature of 46 o C

4 Dimensions, mm 50AZ 016 Electrical box access panel Main disconnect switch Filter access panel Right side view Left side view (2) (1) Rear view Front view 98.5 (1) - Optinal air return duct connection (2) - Optional Power exhaust connection (1) + (2) - Alternative air return duct connection In this case power exhaust option is not used. Control wiring inlet Ø38 Water connection Power wiring inlet

5 Dimensions, mm 50AZ 020 Electrical box access panel Main disconnect switch Filter access panel Right side view Left side view 75 Rear view Front view Control wiring inlet Ø38 Water connection (2) (1) (1) - Optinal air return duct connection (2) - Optional Power exhaust connection (1) + (2) - Alternative air return duct connection In this case power exhaust option is not used. Power wiring inlet

6 Dimensions, mm 50AZ 024, 028 Electrical box access panel Main disconnect switch Filter access panel Right side view Left side view (2) (1) Rear view Front view (1) - Optinal air return duct connection (2) - Optional Power exhaust connection (1) + (2) - Alternative air return duct connection In this case power exhaust option is not used. Control wiring inlet Ø38 Water connection Power wiring inlet

7 Dimensions, mm 50AZ 034, 040 Electrical box access panel 19 Main disconnect switch Filter access panel Right side view Left side view Rear view Front view (2) (1) - Optinal air return duct connection (2) - Optional Power exhaust connection (1) + (2) - Alternative air return duct connection In this case power exhaust option is not used. 112 (1) Control wiring inlet Ø38 Water connection Power wiring inlet

8 Clearances, mm * Clearances required Cooling Capacities * lf the unit includes the optional electric heater or the optional hot water coil this clearance should be 2000 mm. 50AZ Air flow 2528 l/s Ewb Edb Outdoor air temperature C,db C C CAP 43,53 40,05 36,40 32,98 29,28 KW 11,44 11,98 12,62 13,59 15,41 19 SHC 25,11 24,06 22,90 22,16 21,58 21 SHC 29,49 28,33 28,44 26,59 25,85 23 SHC 34,24 33,13 32,03 31,29 30,60 25 SHC 39,78 35,14 36,35 32,92 29,23 17 CAP 46,11 42,63 39,41 36,51 32,50 KW 11, 12,25 12,89 14,07 15,68 21 SHC 25,75 24,69 23,53 22,79 22,21 23 SHC 30,13 29,07 28,02 27,22 26,49 25 SHC 34,87 33,77 32,66 31,92 31,23 27 SHC 40,41 38,94 38,04 36,46 32,45 19 CAP 49,28 45,95 43,00 39,73 35,93 KW 11,87 12,46 13,29 14,23 15,84 23 SHC 26,38 25,33 24,16 23,43 22,85 25 SHC 30,76 29,70 28,65 27,86 27,12 27 SHC 35,51 34,40 33,29 32, 31,87 29 SHC 41,05 39,57 38,67 38,04 36,51 21 CAP 52,60 49,01 45,69 42,89 39,25 KW 11,98 12,57 13,37 14,18 15,95 25 SHC 27,01 25,96 24,80 24,06 23,48 27 SHC 31,39 30,34 29,28 28,49 27,75 29 SHC 36,14 35,03 33,93 33,19 32,50 31 SHC 41,68 40,20 39,31 38,67 37,14 50AZ024 - Air flow 3472 l/s Ewb Edb Outdoor air temperature C,db C C CAP 70,58 65,06 59,65 54,18 47,87 KW 19,95 20,44 21,19 21,76 23,08 19 SHC 39,33 36,78 34,28 32,27 29,19 21 SHC 46,33 43,84 41,24 38,74 36,19 23 SHC 54,29 51,74 49,14 46,54 44,69 25 SHC 60,92 58,43,83 53,28 47,76 17 CAP 76,05 70,58 65,06 59,44 52,91 KW 20,92 21,41 22,11 22,68 24,00 21 SHC 40,07 37,52 35,03 33,01 29,93 23 SHC 47,07 44,58 41,98 39,48 36,94 25 SHC,03 52,49 49,89 47,29 45,43 27 SHC 61,67 59,17 56,57 54,03 51,53 19 CAP 81,68 75,52 70,00 64,75 58,11 KW 21,58 22,02 22,77 23,69 25,05 23 SHC 40,81 38,26 35,77 33,75 30,67 25 SHC 47,82 45,32 42,72 40,23 37,68 27 SHC,78 53,23 50,63 48,03 46,17 29 SHC 62,41 59,92 57,32 54,77 52,27 21 CAP 85,92 80,56 75,09 69,52 63,10 KW 21,89 22,50 23,38 24,26 25,84 25 SHC 41, 39,01 36,51 34,50 31,42 27 SHC 48,56 46,07 43,46 40,97 38,42 29 SHC 56,52 53,97 51,37 48,77 46,91 31 SHC 63,15 60,66 58,06,51 53,02 50AZ Air flow 3444 l/s Ewb Edb Outdoor air temperature C,db C C CAP 54,05 49,74 45,33 41,03 35,52 KW 17,88 18,26 19,32 20,43 22,13 19 SHC 30,36 27,45 24,60 22,04 20,94 21 SHC 37,07 34,16 31,31 29,45 27, 23 SHC 43,73 40,88 38,02 36,12 34,26 25 SHC 50,19 47,34 44,43 40,98 35,47 17 CAP 58,86 54,45 49,94 45,53 40,12 KW 18,79 19,42 19,85 21,39 22,50 21 SHC 31,56 28,65 25,80 23,94 22,14 23 SHC 38,27 35,37 32,51 30,66 28,75 25 SHC 44,93 42,08 39,22 37,32 35,47 27 SHC 51,40 48,54 45,63 43,83 40,07 19 CAP 63,32 58,86 54,10 49,99 44,68 KW 19,10 19,79 20,54 21,70 23,35 23 SHC 32,76 29,86 27,00 25,15 23,34 25 SHC 39,47 36,57 33,71 31,86 29,96 27 SHC 46,17 43,28 40,42 38,52 36,67 29 SHC 52,60 49,74 46,84 45,03 43,18 21 CAP 68,03 63,72 59,36 54,35 49,54 KW 19,53 20,32 21,12 21,92 23,72 25 SHC 33,96 31,06 28,20 26,35 24, 27 SHC 40,68 37,77 34,91 23,04 31,16 29 SHC 47,34 44,48 41,63 39,72 37,87 31 SHC 53,80 50,94 48,04 46,24 44,38 50AZ028 - Air flow 3944 l/s Ewb Edb Outdoor air temperature C,db C C CAP 77,13 72,36 67, 62,73 56,85 KW 27,76 22,62 24,34 26,79 30,18 19 SHC 44,45 42,07 39,68 37,25 34,92 21 SHC 51,94 49,51 47,12 44,35 42,31 23 SHC 59,13 56,70 54,37 51,94 49,51 25 SHC 66,62 64,24 61,76 59,38 56,80 17 CAP 82,62 77,52 72,85 68,03 62,15 KW 22,05 23,35 25,12 27,36 31,12 21 SHC 44,84 42,45 40,07 37,64 35,31 23 SHC 52,33 49,89 47,51 44,74 42,70 25 SHC 59,52 57,09 54,76 52,33 49,89 27 SHC 67,01 64,63 62,15 59,77 57,38 19 CAP 87,39 82,82 78,10 73,38 67,69 KW 22,67 24,13 25,96 28,41 31,64 23 SHC 45,23 42,84 40,46 38,03 35,69 25 SHC 52,72 50,28 47,90 45,13 43,09 27 SHC 59,91 57,48,15 52,72 50,28 29 SHC 67,40 65,02 62,54 60,16 57,77 21 CAP 92,15 87,39 82,72 77,95 72,17 KW 23,27 24,79 26,48 28,82 32,28 25 SHC 45,62 43,23 40,85 38,42 36,08 27 SHC 53,10 50,67 48,29 45,52 43,48 29 SHC 60,30 57,87,54 53,10 50,67 31 SHC 67,79 65,41 62,93 60,54 58,16 Legend CAP - Total cooling capacity, kw Ewb - Indoor unit entering air wet bulb temperature, C Edb - Indoor unit entering air dry bulb temperature, C kw - Compressor power input SHC - Sensible heating capacity, kw

9 50AZ034 - Air flow 50 l/s Ewb Edb Outdoor air temperature C,db C C CAP KW SHC SHC SHC SHC CAP KW SHC SHC SHC SHC CAP KW SHC SHC SHC SHC CAP KW SHC SHC SHC SHC AZ040 - Air flow 50 l/s Ewb Edb Outdoor air temperature C,db C C CAP KW SHC SHC SHC SHC CAP KW SHC SHC SHC SHC CAP KW SHC SHC SHC SHC CAP KW SHC SHC SHC SHC Legend CAP - Total cooling capacity, kw Ewb - Indoor unit entering air wet bulb temperature, C Edb - Indoor unit entering air dry bulb temperature, C kw - Compressor power input SHC - Sensible heating capacity, kw Correction factors Cooling operation 50AZ Multiplier % Nominal flow CAP 0,98 1 1,02 SHC 0,96 1 1,03 KW 0,99 1 1,01 Operating Limits Cooling operation Zone Air temperature Dry bulb Wet bulb Indoor Maximum +35 C +21 C Minimum +19 C +14 C Legend CAP - Total cooling capacity, kw SHC - Sensible heating capacity, kw kw - Compressor power input Outdoor Maximum Minimum +46 C -10 C

10 Fan performance (standard) 50AZ 016 Pulley position Closed Pa ,83 r/s kw 2,26 2,50 2,68 3,04 3,20 3,50 1 turn open Pa ,33 r/s kw 2,10 2,30 2,48 2,80 2,96 3,28 2 turns open Pa ,23 r/s kw 1,98 2,18 2,32 2,65 2,80 3,10 3 turns open Pa ,91 r/s kw 1,86 2,05 2,20 2,50 2,62 2,90 4 turns open Pa ,41 r/s kw 1,76 1,92 2,06 2,34 2,45 2, turns open Pa ,16 r/s kw 1,70 1,86 2,00 2,25 2,36 2,60 Factory setting Pa ,41 r/s kw 1,76 1,92 2,06 2,34 2,45 2,70 std: 4 HP (2,9 kw) 50AZ 020 Pulley position Closed Pa ,91 r/s kw 3,20 2,35 3,65 3,95 4,40 5,00 1 turn open Pa ,08 r/s kw 2,95 3,10 3,45 3,75 4,20 4,80 2 turns open Pa ,25 r/s kw 2,70 2,90 3,25 3,60 4,00 4,60 3 turns open Pa ,41 r/s kw 2, 2,70 3,00 3,40 3,75 4,40 4 turns open Pa ,88 r/s kw 2,25 2,40 2,75 3,10 3, turns open Pa ,16 r/s kw 2,15 2,30 2,65 2,95 3,35 Factory setting Pa ,08 r/s kw 2,95 3,10 3,45 3,75 4,20 4,80 std: 5,5 HP (4 kw) 50AZ 024 Pulley position Closed Pa ,16 r/s kw 4,60 4,90 5,20 5,65 6,15 6,70 1 turn open Pa ,66 r/s kw 4,35 4,60 4,90 5,25 5,75 6,35 2 turns open Pa ,16 r/s kw 4,15 4,35 4,62 4,95 5,45 5,90 3 turns open Pa ,66 r/s kw 4,05 4,15 4,40 4,70 5,15 5,70 4 turns open Pa ,16 r/s kw 3,75 3,90 4,18 4,48 4,90 4,5 turns open Pa ,91 r/s kw 3,65 3,80 4,05 4,38 4,80 Factory setting Pa ,41 r/s kw 3,85 4,00 4,25 4,58 5,00 5,58 std: 7,5 HP (5,5 kw) 50AZ 028 Pulley position Closed Pa ,08 r/s kw 4, 4,75 5,05 5,40 5,85 7,30 1 turn open Pa ,41 r/s kw 4,25 4,45 4,75 5,10 5, 7,00 2 turns open Pa ,75 r/s kw 4,00 4,15 4,45 4,80 5,20 6,40 3 turns open Pa ,08 r/s kw 3,75 3,90 4,20 4,50 4,70 4 turns open Pa ,41 r/s kw 3, 3,70 4,00 4,30 4, 4.5 turns open Pa ,08 r/s kw 3,45 3,60 3,90 4,20 4,45 Factory setting Pa ,41 r/s kw 3,85 4,05 4,35 4,65 4,95 6,00 std: 7,5 HP (5,5 kw) 50AZ 034 Pulley position 5000, Closed Pa ,71 r/s kw 5,97 6,50 7,03 7,28 7,52 7,90 1 turn open Pa ,30 r/s kw 5,77 6,23 6,70 6,89 7,08 7,42 2 turns open Pa ,88 r/s kw 5,58 6,00 6,40 6,65 6,99 7,13 3 turns open Pa ,46 r/s kw 5,29 5,65 6,02 6,31 6,50 6,87 4 turns open Pa ,05 r/s kw 5,05 5,38 5,77 6,00 6,21 6,45 Factory setting Pa ,88 r/s kw 5,58 6,00 6,40 6,65 6,99 7,13 std: 10 HP (7,5 kw) 50AZ 040 Pulley position Closed Pa ,63 r/s kw 6,05 6, 6,95 7,25 7,45 7,90 1 turn open Pa ,21 r/s kw 5,80 6,30 6,74 7,00 7,25 7,70 2 turns open Pa ,80 r/s kw 5,45 5,95 6,45 6,70 6,90 7,25 3 turns open Pa ,38 r/s kw 5,15 5,60 6,10 6,30 6, 6,90 4 turns open Pa ,96 r/s kw 4,95 5,45 5,90 6,10 6,35 6,70 Factory setting Pa ,21 r/s kw 5,80 6,30 6,74 7,00 7,25 7,70 std: 10 HP (7,5 kw) Legend: Pa External static pressure kw Fan power input Higher than the nominal motor power

11 Fan performance (optional drive) 50AZ 016 Pulley position Closed Pa ,08 r/s kw 3,40 3,65 3,85 4,20 4,38 4,68 1 turn open Pa ,25 r/s kw 3,15 3,40 3,58 3,92 4,10 4,45 2 turns open Pa ,58 r/s kw 2,86 3,10 3,28 3,62 3,80 4,12 3 turns open Pa ,41 r/s kw 2,62 2,85 3,02 3,32 3,48 3,80 4 turns open Pa ,75 r/s kw 2,50 2,68 2,84 3,14 3,28 3, turns open Pa ,41 r/s kw 2,40 2,60 2,74 3,04 3,18 3,50 std: 5,5 HP (4 kw) 50AZ 020 Pulley position Closed Pa ,00 r/s kw 5,24 5,50 6,00 6,48 6,96 7,58 1 turn open Pa ,16 r/s kw 4,95 5,20 5,50 6,06 6,50 7,10 2 turns open Pa ,33 r/s kw 4,50 4,72 5,05 5,44 5,80 6,30 3 turns open Pa ,50 r/s kw 3,98 4,15 4,15 4,82 4,15 5, 4 turns open Pa ,66 r/s kw 3,58 3,74 4,00 4,26 4, turns open Pa ,25 r/s kw 3,38 3,52 3,74 4,00 4,24 std: 7,5 HP (5,5 kw) 50AZ 024 Pulley position Closed Pa ,16 r/s kw 5,75 6,05 6,35 6,65 7,00 1 turn open Pa ,58 r/s kw 5,65 5,90 6,20 6,50 6,90 2 turns open Pa ,91 r/s kw 5,50 5,75 6,05 6,40 6,75 3 turns open Pa ,33 r/s kw 5,20 5,45 5,75 6,05 6,45 4 turns open Pa ,66 r/s kw 4,80 5,05 5,35 5,65 6,10 4,5 turns open Pa ,41 r/s kw 4,65 4,90 5,15 5,45 5,90 std: 7,5 HP (5,5 kw) 50AZ 028 Pulley position Closed Pa ,41 r/s kw 5,45 5,85 6,20 6,65 6,90 1 turn open Pa ,75 r/s kw 5,05 5,45 5,80 6,15 6,50 2 turns open Pa ,08 r/s kw 4,75 5,20 5,50 5,80 6,10 3 turns open Pa ,41 r/s kw 4,35 4,90 5,20 5,45 5,75 4 turns open Pa ,75 r/s kw 4,20 4,70 4,95 5,15 5, turns open Pa ,41 r/s kw 4,10 4,60 4,80 5,00 5,20 std: 7,5 HP (5,5 kw) 50AZ 034 Pulley position Closed Pa ,83 r/s kw 8,00 8,25 8,90 9,40 9,85 10,25 1 turn open Pa ,41 r/s kw 7,10 7,40 8,00 8,50 9,05 9,50 2 turns open Pa r/s kw 6,70 6,95 7, 8,10 8,45 9,00 3 turns open Pa ,58 r/s kw 6,40 6,70 7,20 7,75 8,25 8,60 4 turns open Pa ,16 r/s kw 6,15 6,40 7,00 7, 7,95 8,10 std: 15 HP (11 kw) 50AZ 040 Pulley position Closed Pa ,75 r/s kw 8,00 8,25 8,85 9,35 9,80 10,20 1 turn open Pa ,33 r/s kw 7,05 7,41 7,95 8,45 9,00 9,48 2 turns open Pa ,91 r/s kw 6,65 6,90 7,50 8,05 8,40 8,95 3 turns open Pa ,51 r/s kw 6,35 6,65 7,15 7,70 8,20 8, 4 turns open Pa ,50 r/s kw 6,10 6,35 6,95 7,50 7,95 8,05 std: 15 HP (11 kw) Legend: Pa External static pressure kw Fan power input Higher than the nominal motor power

12 Accessories Hot water coil data (sizes ) (60 kw coil) % glycol EWT EDB kw l/s kw l/s kw l/s kw l/s kw l/s kw l/s kw l/s kw l/s kw l/s kw l/s kw l/s kw l/s kw l/s kw l/s kw l/s ,2 0,74 56,9 0,71 53,7 0,71 65,8 0,79 50,9 0,76 57,7 0,76 59,0 0,82 64,5 0,80 61,3 0,81 72,2 0,86 68,1 0,84 65,0 0,86 73,8 0,88 70,0 0,86 67,1 0, ,9 0,54 38,8 0,48 36,6 0,48 48,3 0,58 44,0 0,54 40,9 0,54 51,6 0,62 47,8 0,59 44,4 0,59,3 0,66 50,6 0,63 47,5 0,63 57,4 0,68 52,1 0,65 49,2 0, ,0 0,35 25,5 0,32 23,2 0,31 32,1 0,38 27,9 0,35 25,6 0,34 34,8 0,42 30,0 0,37 27,7 0,37 37,5 0,45 32,0 0,40 29,7 0,39 39,1 0,47 33,3 0,42 30,8 0, ,8 0,67 50,5 0,63 47,9 0,63 60,2 0,72 54,9 0,68 51,8 0,69 63,6 0,76 58,5 0,72,0 0,73 66,3 0,79 61,5 0,76 57,9 0,77 67,7 0,80 63,2 0,76 59,8 0, ,4 0,46 32,6 0,40 31,2 0,41 42,8 0,51 37,1 0,46 34,9 0,46 46,3 0, 40,6 0,50 38,1 0,50 49,3 0,59 43,4 0,54 41,0 0,54 51,1 0,60 44,7 0, 42,4 0, 60 24,9 0,30 22,9 0,28 20,5 0,27 27,5 0,33 26,5 0,33 22,5 0,30 29,9 0,36 28,6 0,35 24,2 0,32 32,6 0,39 29,2 0,36 26,1 0,35 34,0 0,40 30,4 0,37 27,0 0, ,4 0,59 43,9 0,54 41,9 0, 53,6 0,64 47,1 0,58 46,1 0,61 56,6 0,68 50,2 0,65 49,0 0,65 58,9 0,70 53,5 0,75 50,8 0,67 60,1 0,71,0 0,75 52,4 0, ,5 0,39 28,4 0,35 26,2 0,35 36,4 0,43 30,9 0,38 28,8 0,38 39,3 0,47 33,2 0,41 31,1 0,41 41,4 0,50 35,8 0,44 33,6 0,44 42,9 0,51 36,8 0,45 34,7 0, ,1 0, ,3 0,28 22,1 0,27 18,9 0,25 25,5 0,30 23,8 0,30 20,6 0,27 27,9 0,33 24,9 0,31 22,0 0,29 29,1 0,33 25,9 0,32 23,0 0, ,3 0,54 39,6 0,49 37,3 0,49 47,2 0,56 41,5 0,51 39,2 0,52 49,4 0,59 43,9 0,54 41,6 0, 52,2 0,63 47,4 0,59 45,1 0,60 53,5 0,64 48,7 0,59 46,5 0, ,0 0,35 25,9 0,32 23,2 0,31 31,0 0,37 27,2 0,34 25,0 0,33 33,0 0,39 28,6 0,35 26,7 0,35 35,2 0,42 30,6 0,38 28,5 0,38 36,4 0,43 31,4 0,39 29,4 0, ,6 0,26 21,7 0, ,3 0,28 22,8 0,28 20,2 0,27 24,3 0,28 23,7 0,29 21,1 0, ,3 0,46 32,5 0,40 30,2 0,47 41,2 0,49 35,3 0,44 32,8 0,43 43,5 0,52 37,5 0,47 35,0 0,46 45,5 0,54 39,6 0,49 37,2 0,49 46,3 0, 40,6 0,49 38,3 0, ,8 0,30 23,7 0,29 20,3 0,27 26,1 0,31 24,3 0,30 21,8 0,29 27,4 0,33 24,9 0,31 22,8 0,30 28,9 0,35 25,8 0,32 23,6 0,31 29,9 0,36 26,4 0,33 24,3 0, (100 kw coil) (sizes ) % glycol EWT EDB kw l/s kw l/s kw l/s kw l/s kw l/s kw l/s kw l/s kw l/s kw l/s kw l/s kw l/s kw l/s kw l/s kw l/s kw l/s ,9 0,99 76,7 0,95 73,2 0,97 93,0 1,11 85,9 1,07 81,5 1,08 101,5 1,21 93,8 1,16 89,0 1,18 109,6 1,31 101,8 1,26 97,0 1,28 113,0 1,32 107,6 1,32 101,2 1,33 70,8 0,67 50,1 0,62 45,5 0,60 61,4 0,73 56,1 0,69 50,4 0,67 66,6 0,80 61,1 0,76,0 0,73 72,0 0,86 66,1 0,82 59,9 0,79 74,6 0,87 70,0 0,86 62,5 0, ,1 0,42 31,1 0,39 22,6 0,30 40,2 0,48 35,6 0,44 25,6 0,34 44,9 0,54 38,5 0,49 28,2 0,37 49,9 0,60 43,5 0,54 30,7 0,41 51,7 0,61 46,0 0,57 31,9 0, ,6 0,87 66,6 0,83 52,6 0,83 89,9 0,97 73,9 0,92 69,4 0,92 87,9 1,05 80,2 0,99 75,5 1,00 94,5 1,13 86,4 1,07 81,8 1,08 97,4 1,14 91,3 1,12 85,3 1, ,6 0,58 42,9 0,53 38,2 0,51 53,6 0,64 47,8 0,59 42,5 0,56 58,1 0,69 52,1 0,65 46,2 0,61 63,2 0,75 56,7 0,70 49,9 0,66 65,5 0,76 60,0 0,73 52,0 0, ,4 0,36 26,1 0,32 20,3 0,27 34,6 0,41 29,9 0,37 23,0 0,30 38,1 0,46 33,2 0,41 25,3 0,33 41,1 0,49 36,3 0,45 27,5 0,36 42,9 0,50 38,4 0,47 28,6 0, ,5 0,76 57,6 0,71 53,0 0,70 70,4 0,84 63,7 0,79 58,8 0,78 76,3 1,94 68,9 0,85 64,0 0,85 82,0 0,98 74,1 0,92 69,3 0,92 84,5 0,99 78,3 0,96 72,2 0, ,9 0,50 36,4 0,45 31,3 0,41 46,2 0, 40,4 0,50 35,0 0,76 50,2 0,60 44,0 0, 38,1 0,50 54,6 0,65 47,9 0,59 40,9 0,54 56,6 0,66 50,7 0,61 42,6 0, ,2 0,31 22,0 0, ,7 0,35 25,1 0,31 20,4 0,27 32,4 0,39 27,6 0,34 22,5 0,30 34,6 0,41 29,9 0,37 24,5 0,32 35,8 0,42 30,8 0,38 25,5 0, ,5 0,69 51,6 0,64 46,4 0,61 63,7 0,76 57,2 0,71 51,8 0,69 69,0 0,82 62,1 0,77 56,7 0,75 74,2 0,89 66,9 0,83 61,8 0,82 76,4 0,90 70,7 0,86 64,4 0, ,3 0,45 32,0 0,40 26,5 0,35 41,1 0,49 35,4 0,44 29,7 0,39 44,6 0,53 38,6 0,48 32,4 0,43 48,4 0,58 41,8 0,52 34,8 0,46 50,1 0,59 44,2 0,53 36,2 0, ,4 0, ,5 0,32 21,9 0, ,8 0,37 23,8 0,30 20,6,27 30,6 0,37 25,6 0,32 22,4 0,30 31,6 0,38 26,4 0,33 23,3 0, ,2 0,62 46,2 0,57 40,4 0,53 57,8 0,69 51,9 0,64 45,6 0,60 62,8 0,76 56,7 0,70 50,5 0,67 67,9 0,81 61,4 0,76,7 0,74 69,9 0,82 64,9 0,79 58,0 0, ,9 0,39 27,9 0,35 21,9 0,29 36,3 0,43 31,0 0,38 24,7 0,33 38,3 0,47 33,6 0,45 27,0 0,36 42,3 0,51 36,0 0,45 29,2 0,39 43,8 0,52 38,0 0,45 30,4 0, ,5 0, ,6 0, ,7 0,31 20,4 0, ,5 0,33 21,8 0,27 20,4 0,27 28,4 0,34 22,5 0,28 21,2 0,28 (130 kw coil) (sizes ) % glycol EWT EDB kw l/s kw l/s kw l/s kw l/s kw l/s kw l/s kw l/s kw l/s kw l/s ,0 2,00 1,7 1,92 148,4 1,95 172,9 2,06 164,6 2,03 154,8 2,03 178,2 2,12 173,2 2,14 161,4 2, ,1 1,31 101,1 1,25 91,0 1,19 114,1 1,36 107,1 1,32 95,6 1,25 117,6 1,40 113,1 1,39 99,7 1, ,3 0,91 66,5 0,82 46,9 0,61 79,1 0,94 70,4 0,87 48,8 0,64 81,5 0,97 74,3 0,91 50,9 0, ,5 1,72 132,2 1,63 125,0 1,64 149,0 1,78 139,7 1,72 130,5 1,71 153,4 1,83 147,5 1,82 136,1 1, ,7 1,15 86,7 1,07 76,3 1,00 100,2 1,19 91,8 1,13 79,5 1,04 103,2 1,23 96,9 1,19 82,9 1, ,9 0,75,5 0,68 42,0 0, 65,6 0,78 58,7 0,72 43,7 0,57 67,5 0,80 61,9 0,76 45,6 0, ,4 1,49 113,4 1,40 106,0 1,39 130,0 1, 119,8 1,48 110,4 1,45 133,9 1,60 126,5 1,56 115,1 1, ,5 0,99 73,3 0,90 62,5 0,82 86,6 1,03 77,0 0,96 65,1 0,85 89,2 1,06 81,9 1,01 67,9 0, ,9 0,63 45,7 0,56 37,5 0,49 54,7 0,65 47,1 0,58 39,0 0,51 56,3 0,67 49,7 0,61 40,7 0, ,5 1,35 102,3 1,26 94,5 1,24 116,9 1,39 108,1 1,33 98,5 1,29 120,4 1,43 114,1 1,41 102,7 1, ,0 0,88 63,9 0,79 53,2 0,69 76,6 0,91 67,6 0,83,3 0,72 78,9 0,94 71,4 0,88 57,7 0, ,8 0,56 39,1 0,48 34,3 0,45 48,3 0,57 40,4 0,50 35,6 0,46 49,7 0,59 42,6 0,52 37,1 0, ,9 1,24 93,9 1,16 85,2 1,12 106,9 1,27 99,3 1,22 88,7 1,16 110,1 1,31 104,8 1,29 92,5 1, ,7 0,77,1 0,68 44,7 0,58 67,0 0,80 58,1 0,71 46,5 0,61 69,0 0,82 61,3 0,75 48,5 0, ,1 0,50 33,3 0,41 31,2 0,41 43,4 0,52 34,4 0,42 32,4 0,42 44,7 0,53 36,3 0,44 33,8 0,44 Legend kw - Heating Capacity, kw EWT - Entering Water Temperature, C EDB - Entering Dry Bulb Temperature, C l/s - Water flow

13 Water pressure drop 60 kw 100 kw 130 kw Static pressure loss, options Options Air Flow (l/s) Pressure Drop (Pa) Electric heater Economizer Hot water coil 60 kw 58,1 84,7 115,3 156,9 187,5 100 kw 58,1 84,7 115,3 156,9 187,5 Pressure drop (kpa) ,1 0,2 0,3 0,4 0,5 0,6 Water flow (l/s) 0,7 0,8 0, Guide specifications Rooftop 50AZ Cooling only Rooftop Units Part 1 - General Quality assurance Rooftop units comply with requirements of European directives: - Machinery directive 98/37/CE, modified, - Low voltage directive 73/23/EEC, modified, - Electromagnetic compatibility directive 89/336/EEC, modified and with the applicable recommendations of European Standards, - Machine safety, electrical equipment in machines, general regulations: EN , - Radiated electromagnetic emissions: EN , - Conducted electromagnetic emissions: EN , - Electromagnetic immunity EN , - Pressure Equipment Directive 97/23/EC. 50AZ units have been designed and tested in a facility with a quality assurance system certified ISO AZ units have been assembled in a facility with an environment management system certified ISO All units undergo a run test before shipment. Part 2 - Products Equipment Compressor Hermetic scroll and reciprocating compressors, cooled by suction gas with overload protection through an internal thermostat and/or thermal relay. Oil level sight glass and polyolester synthetic oil charge. Air heat exchangers 50AZ outdoor and indoor coils with precoated corrugated aluminum fins expanded into grooved copper tubes. Options Air Flow (l/s) Pressure Drop (Pa) Electric heater Economizer Hot water coil 130 kw 86,2 101,1 118,6 Electric heaters kw 18 ( one stage ) 27 ( one stage ) 18 ( 9+9 ) two stages 27 ( 18+9 ) tw o sta g es 36 ( ) two stages 54 ( ) two stages 72 ( ) two stages 36 ( ) three stages 45 ( ) three stages Outdoor fan Low-noise axial Carrier Flying Bird fan with 11 blades and a rotating shroud, made of a composite material. Three phases, two-speed motor, insulation class F, protection category IP, overload protection by thermal relay. Vertical air flow with protection grille made of steel wire, coated in polyethylene. Indoor fan Double-inlet indoor fans have forward-curved blades. They are statically and dynamically balanced for quiet, vibration free operation. They are factory-set to supply nominal air volume and static pressure. The fans are powered by generously sized three-phase motors via adjustable belt and pulley transmission. Refrigerant circuit Each circuit includes: moisture sight glass, two-way expansion device, drier, heat exchanger, high-pressure safety valve, pressure and temperature sensors, external manual reset high pressure switch, and a refrigerant change of HFC-407C. Control and power circuit control box The control box is accessible via a hinged door. It includes a main disconnect switch, fuses and circuit breakers, compressor, indoor and outdoor fan contactors, thermal relays, low-voltage control circuit transformer (24 V control circuit) and the Pro-Dialog control system. The whole unit is supplied from a single power connection point (three-phase supply without neutral). Chassis/cabinet Chassis and cabinet made of powder painted galvanized steel sheet (light gray color RAL 7035). Removable panels with 1/4 turn locks. Order No , New, January 2004 Manufacturer reserves the right to change any product specifications without notice. The cover photo is soley for illustration purpose, is not contractually binding.

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS

More information

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating

More information

SECTION 23 81 43 HEAT PUMPS

SECTION 23 81 43 HEAT PUMPS SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:

More information

Cool Design for Homes and Offices

Cool Design for Homes and Offices AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive, and designed to fit any space: there are Cool Design for Homes and Offices a lot of reasons why Air Blue air conditioners

More information

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system. ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2

More information

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT 48/50E-4SB 48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT GAS HEAT ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED

More information

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing

More information

CE6500 Energy Recovery Ventilator

CE6500 Energy Recovery Ventilator ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled

More information

MAC-120HE-01 Air-Cooled Chiller

MAC-120HE-01 Air-Cooled Chiller MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01

More information

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.

More information

CRAC Precision climate control units for data centres

CRAC Precision climate control units for data centres CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have

More information

SECTION 15732 AIR CONDITIONING UNIT

SECTION 15732 AIR CONDITIONING UNIT SECTION 15732 AIR CONDITIONING UNIT PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Packaged, split system air conditioning unit No. 1. 1.02 REFERENCES A. Air-Conditioning, Heating, and Refrigeration

More information

marine/bespoke split applications

marine/bespoke split applications split applications marine/bespoke evaporators, condensers and split air conditioning systems suitable for a multitude of applications such as coastal, extreme high and low ambients, harsh dusty environments

More information

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 Technical Specifications Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 For chiller storage of all sorts of items Chiller storage temperature: 2-5 C Provides excellent thermal efficiency

More information

RPV - RP - RA air handling units

RPV - RP - RA air handling units APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP

More information

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None 1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements

More information

TWE+TTA TWE+TWA 6.25-20 T.R.

TWE+TTA TWE+TWA 6.25-20 T.R. TWE+TTA TWE+TWA 6.25-20 T.R. Main features : TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drive centrifugal fan motor. Aluminium fin coil with copper-tubes.

More information

Commercial Gas Furnace Upflow

Commercial Gas Furnace Upflow Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted

More information

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS NOR-LAKE, INCORPORATED 727 Second Street P.O. Box 248 Hudson, Wisconsin 54016 800-955-5253 715-386-2323 866-961-5253 Parts 800-388-5253 Service 715-386-4291 FAX www.norlake.com Split-Pak Pre-Assembled

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................

More information

catalog Single Package Vertical Air Conditioners and Heat Pumps

catalog Single Package Vertical Air Conditioners and Heat Pumps catalog Single Package Vertical Air Conditioners and Heat Pumps Catalog: SK145.00-EG1 (1008) TABLE OF CONTENTS Single Package Vertical Units Introduction...............................................................................

More information

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW -

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW - AIR-COOLED CHILLERS APPLIED SYSTEMS www.daikin.eu Cooling Only Heat pump EUWA*5-24KAZW - EUWY*5-24KAZW - Environmental Awareness Daikin and the Environment In recent years, motivated by a global awareness

More information

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER

More information

Chilled Water Fan Coil Unit

Chilled Water Fan Coil Unit Chilled Water Fan Unit Model: HFCF02~HFCF14 Airflow Range: 200~2400m 3 /h Features and Benefits The Best Choice for Comfort The Best Results - Quiet Comfort Low noise permanent split capacitor motor. Metal

More information

HP switch LP switch Discharge thermo Comp. Surface thermo

HP switch LP switch Discharge thermo Comp. Surface thermo 1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer

More information

Condensing unit type EPSILON-ECHOS LE Technical information manual

Condensing unit type EPSILON-ECHOS LE Technical information manual Condensing unit type EPSILON-ECHOS LE Technical information manual 2 > EPSILON ECHOS Water chiller > EPSILON ECHOS /HP Reversible heat pump > EPSILON ECHOS /ST Water chiller with storage tank and pumps

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

5-21kW. Ecotel Indoor Range. - 21kW. > Ecotel Indoor Range. www.airedale.com. Typical Applications

5-21kW. Ecotel Indoor Range. - 21kW. > Ecotel Indoor Range. www.airedale.com. Typical Applications 5-21kW - 21kW > Ecotel Indoor Range Typical Applications > Telecommunications > Internet service providers > Computer rooms > Switching / Relay stations www.airedale.com Specifications Ecotel Indoor The

More information

RRV934. Multi-controller. Synco living

RRV934. Multi-controller. Synco living s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard

More information

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

SINGLE PACKAGE VERTICAL AIR CONDITIONERS SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,

More information

KONRAD. Hybrid Fancoil Series

KONRAD. Hybrid Fancoil Series KONRAD Hybrid Fancoil Series Konrad is an innovative radiator which cools you down and warms you up. Indeed, it cools in summer and heats in winter; but it makes it with an incomparable quietness. Thanks

More information

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm) UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery

More information

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide

More information

HEATER, AIR CONDITIONING AND VENTILATION

HEATER, AIR CONDITIONING AND VENTILATION 55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT

More information

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series SWIMMING POOL AIR-HANDLING UNITS KU-DB Series ME20 proklima 2 SWIMMING POOL AIR-HANDLING UNITS - KU-DB Series proklima 3 TABLE OF CONTENTS 1 Introduction page 3 2 Features page 4 SWIMMING POOL AREA t =

More information

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,

More information

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History

More information

YCAA-B AIR COOLED LIQUID CHILLER

YCAA-B AIR COOLED LIQUID CHILLER YCAA-B AIR COOLED LIQUID CHILLER R407C REFRIGERANT COOLING CAPACITIES 46 kw to 152 kw York YCAA-B twin refrigerant circuit air cooled liquid chillers are a compact design suitable for chilled water or

More information

NSN 4120-01-21 4-3692

NSN 4120-01-21 4-3692 *TM 9-4120-388-14 TECHNICAL MANUAL Operator s, Unit, Direct Support, And General Support Maintenance Manual AIR CONDITIONER, VERTICAL, COMPACT, 18,000 BTU/HR 208 VOLT, 3 PHASE, 50/60 HERTZ NSN 4120-01-21

More information

PRODUCT CATALOGUE AIR COOLED CONDENSING UNIT RA

PRODUCT CATALOGUE AIR COOLED CONDENSING UNIT RA PRODUT TLOGUE IR OOLED ONDENSING UNIT R English/02-2005 IR OOLED ONDENSING UNIT INTRODUTION TO THE RNGE The R air-cooled units are developed from the EOLOGI liquid chiller range and share the same design

More information

CoolTeg Plus Chilled Water (CW) version: AC-TCW

CoolTeg Plus Chilled Water (CW) version: AC-TCW version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420

More information

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability PFD-P250VM-E PUHY-P250YJM-A(-BS) PUHY-P500YSJM-A(-BS) PQHY-P250YHM-A CLOSE CONTROL SYSTEM MITSUBISHI ELECTRIC s Close Control System (PFD series) is specifically designed for computer rooms, laboratories

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-01 Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess

More information

Installation Manual CLIFC Fan & Coil Variable Speed

Installation Manual CLIFC Fan & Coil Variable Speed Installation Manual CLIFC Fan & Coil Variable Speed General Description GENERAL DESCRIPTION FANS EQUIPMENT Totally Factory assembled within the unit all piping, wiring, and required controls for operation

More information

ice 3 FLUID TO FLUID HEAT PUMP

ice 3 FLUID TO FLUID HEAT PUMP ice 3 FLUID TO FLUID HEAT PUMP SUBMITTAL DATA (888) 530-7713 P O Box 5, Wentworth, H 03282 Rev.3 (5-30-14) ice 3, IC-2040 Fluid-to-Fluid R-410a Heat Pump Engineering Guide Specifications General otes:

More information

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as: CA SERIES T he CA Aquarius Series Console Units offer the answer to providing heating and cooling to areas where space and access is limited. Office buildings, hotel/motels, schools and assisted living

More information

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-A Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs

More information

Chilled Water Precision Air Conditioner For Critical Application

Chilled Water Precision Air Conditioner For Critical Application AIRSYS-P-SC-OPTIMA-HD-E1304V01.2 HD Chilled Water Precision Air Conditioner For Critical Application Cooling capacity: 42.1kW~161.5kW OPTIMA product family is designed for medium to large data center.

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000

More information

Local Dealer: www.cebrands.com

Local Dealer: www.cebrands.com Local Dealer: C.E. LLC - Miami, FL USA www.cebrands.com Res2012-Rev2 QUALITY YOU CAN FEEL Residential Product Line >TCA7,9 Tempstar SmartComfort TXT + Air Conditioner Featuring The Observer Communication

More information

Appendix - Controllers 179

Appendix - Controllers 179 Version: 200703 Appendix - Controllers 179 -3- -4- -5- -6- -7- -8- 2. Specifications 2.1 Specifications for inverter units item Model AB182ACERA Function cooling heating Capacity kw 5.01.8--5.8 5.22.0---6.2

More information

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact: 7610.478.16 8/99 INSTRUCTION MANUAL Models 8005, 8010, 8015 For Sales & Service please contact: CENTRAIR Air Systems & Supplies Phone: 705-722-5747 Fax: 705-722-5458 Email: sales@centrair.ca Website: www.centrair.ca

More information

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of

More information

A. Section includes air conditioning units, controls and control panels.

A. Section includes air conditioning units, controls and control panels. SECTION 23 81 23 - COMPUTER-ROOM AIR-CONDITIONERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes air conditioning units, controls and control panels. 1.2 REFERENCES A. Air-Conditioning, Heating, and

More information

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water 2 to 15 tons Water-Cooled and Chilled Water Unique Solutions for Challenging HVAC Projects Your Choice for Limited Space Applications Water-Cooled Chilled Water The VertiCool Space Saver allows installation

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer

More information

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner

More information

ARMSTRONG AIR HEAT PUMPS www.armstrongair.com

ARMSTRONG AIR HEAT PUMPS www.armstrongair.com INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM EFC/EFV... 5-10 electric Heat Kits... 5-11 evaporator coils EC1P / EM1P UPFLOW / COUNTERFLOW APPLICATIONS and upflow / horizontal applications (CASED)... 5-6 5-7

More information

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to: OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND

More information

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator

More information

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1 SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH

More information

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches

More information

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved Sanyo Section : Section : Section : Section : Section : sip Modbus Guide Configuration Modbus Table Technical Specification Pinouts, Cable Connections & Wiring Alarm Fault Codes Issue : February 009 Section

More information

Power consumption (kw)

Power consumption (kw) OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components

More information

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts Lo w p r o f i l e small air handlers and extract fan units Duties to 0.55m 3 /sec Available with the Electroline fitted control panel Ceiling void friendly - unit heights from 190mm to 350mm Airline VES

More information

GCS16 GCS20 WARNING CAUTION

GCS16 GCS20 WARNING CAUTION Service Literature Corp. 0110 L6 Revised 12 2004 GCS16/GCS20 SERIES UNITS GCS16 GCS20 2 to 5 Ton GCS16/20 series units in the 2 to 5 ton (7.0 to 17.0 kw) cooling size are packaged combination gas heat

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Silver 14 4A6H4 1 1 /2-5 Tons PUB. NO. 12-1175-07 Contents Features and Benefits 2 Model Nomenclature 3 General 4 Product Specifications 4 A-weighted Sound Power Level [db(a)]

More information

The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY

The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY About HDT Nordic HDT Global, in business for over 75 years, acquired Nordic Air in 2010. Nordic was founded

More information

HEAVY DUTY STORAGE GAS

HEAVY DUTY STORAGE GAS Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many

More information

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw ,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted

More information

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-211 REV. 7 Supersedes Form No. C11-211 Rev. 6 INDOOR COILS RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM

More information

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac II air conditioner is a vertical, wall mounted, cost effective air conditioner

More information

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams Chapter 5 Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams Objectives Upon completion of this course, you will be able to: Explain what electrical loads are and their general purpose

More information

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION Air Conditioning Central Heating & Cooling BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION INSTALLATION AND SERVICE MANUAL 2 PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: PHONE NUMBER: INSTALLATION

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XR17 4TTR7 2, 3, 4 & 5 Tons PUB. NO. 22-1884-01 Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER All Aluminum SPINE FIN coil DURATUFF

More information

WWZ High efficiency HYBRID heat pumps with E.V.I compressor in two sections

WWZ High efficiency HYBRID heat pumps with E.V.I compressor in two sections High efficiency HYRID heat pumps with E.V.I compressor in two sections infolinia: +48 691 262 691-20 +43 +65 E.V.I..O.P. 4,1 The series of high efficiency hybrid heat pumps has been specifically designed

More information

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC Technical Concept Filter Fan Unit SILENT Type SILENT AC Type SILENT EC Filter Fan Unit SILENT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Data XL20i 4TWZ0024, 036, 048 & 060 with ComfortLink II and Charge Assist 2, 3, 4 & 5 Tons PUB. NO. 22-1826-01 Features and Benefits Two Climatuff compressors Efficiency

More information

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-213 REV. 4 Supersedes Form No. C11-213 Rev. 3 INDOOR COILS RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM

More information

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages.

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages. Défumair XR smoke-extraction fan extraction casing for kitchen at F400-120 Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally

More information

D SERIES MODULAR AIR-COOLED SCROLL CHILLER. TECHNICAL SALES GUIDE-50Hz CAPACITY RANGE:65~130kW SUPER HIGH AMBIENT OPERATION TO 43

D SERIES MODULAR AIR-COOLED SCROLL CHILLER. TECHNICAL SALES GUIDE-50Hz CAPACITY RANGE:65~130kW SUPER HIGH AMBIENT OPERATION TO 43 D SERIES MODULAR AIR-COOLED SCROLL CHILLER TECHNICAL SALES GUIDE-50Hz CAPACITY RANGE:65~130kW SUPER HIGH AMBIENT OPERATION TO 43 CONTENTS 1.MODELS LIST... 3 2.NOMENCLATURE... 3 3.FEATURES... 3 4.PRODUCT

More information

Operating Instructions Split System Air Conditioner

Operating Instructions Split System Air Conditioner Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This

More information

www.inspection-for-industry.com

www.inspection-for-industry.com Quality Control Form (TEST RUNNING RECORD FOR AIR HANDLING UNIT) SUB POWER SUPPLY: MAIN POWER V, Hz, CONTROL V, Blower 1 kw, Blower 2 kw, Compressor: (1) kw (2) kw (3) kw (4) kw Heating Element: kw 1.

More information

Single Package Vertical Air Conditioners. Vert-I-Pak

Single Package Vertical Air Conditioners. Vert-I-Pak Single Package Vertical Air Conditioners Vert-I-Pak Installs easily in a closet for quiet operation and provides a more homelike appearance for your guests. THE EXPERTS IN ROOM AIR CONDITIONING A Better

More information

Product Data. Split System Cooling 22-1904-1F-EN. March 2015

Product Data. Split System Cooling 22-1904-1F-EN. March 2015 Product Data Split System Cooling 4TTR4018L1000A 4TTR4024L1000A 4TTR4025L1000A 4TTR4030L1000A 4TTR4031L1000A 4TTR4036L1000A 4TTR4037L1000A 4TTR4042L1000A 4TTR4043L1000A 4TTR4048L1000A 4TTR4060L1000A Note:

More information

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER

More information

Manual Code VR-197-0-0002

Manual Code VR-197-0-0002 USE, MAINTENANCE AND INSTALLATION MANUAL AIR CONDITIONERS FOR ELECTRICAL ENCLOSURES Manual Code VR-197-0-0002 VZ1550 VZ1850 VZ1400 VZ2000 ABB SACE S.p.A. An ABB Group Company Automation and Distribution

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI Page 2 / 16 CONTENTS 1 GENERAL... 3 2 SAFETY... 3 2.1 Safety instructions... 3 2.2 Correct use... 3 3 DESCRIPTION

More information

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED

More information

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-212 REV. 1 Supersedes Form No. C11-212 INDOOR COILS RCFM- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES

More information

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-211 REV. 3 Supersedes Form No. C11-211 Rev. 2 INDOOR COILS RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_071015. Products that provide lasting solutions.

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_071015. Products that provide lasting solutions. LH and GH/GL Series UNIT COOLERS Technical Bulletin: LHGH_001_07101 Products that provide lasting solutions. LH Series Unit Coolers Dual Discharge Low Hite Series At 9 1/ maximum height, the LH Series

More information