Data Centre Cooling Strategies The Changing Landscape.. Mark Deguara Director Data Centre Solutions ANZ

Size: px
Start display at page:

Download "Data Centre Cooling Strategies The Changing Landscape.. Mark Deguara Director Data Centre Solutions ANZ"

Transcription

1 Data Centre Cooling Strategies The Changing Landscape.. Mark Deguara Director Data Centre Solutions ANZ

2 Redefining Huge 2 State of the Data Centre, Emerson Network Power

3 State of the Data Centre, Emerson Network Power Failure is Not An Option 3

4 4 Powerful Forces Are Driving Change in Data Centre Infrastructure External forces changing the business climate Virtualization/ Cloud Data Centre & Server Consolidation Data Centre Modularity More with Less Interdependent apps/functions Always on Availability Expectations Business and technology forces pressing on the data centre Higher density Alternative Power/Cooling Technologies IT Exerting Greater Influence than Facilities Efficiency & Green Initiatives 4 Data Centers are Using Less Power and Cooling

5 Today s Data Centre Needs Efficiency Protection Scalability Simplification Cost reduction Resource utilization Spending optimization Higher availability, SLA assurance Compliance and governance Accuracy Provisioning Permissioning Responsiveness Standardization Consistency Leverage existing tools and skill sets Cheaper Stronger Faster Easier Need: a real-time, resilient data centre that makes the future of your business possible, with; the agility and flexibility to meet customer demands, adapt to rapid changes, operate at high efficiency and comply with requirements for risk management and protection 5 5

6 Today s Data Centre Needs Efficiency Protection Scalability Simplification Cost reduction Resource utilization Spending optimization Higher availability, SLA assurance Compliance and governance Accuracy Provisioning Permissioning Responsiveness Standardization Consistency Leverage existing tools and skill sets Cheaper Stronger Faster Easier Need: a real-time, resilient data centre that makes the future of your business possible, with; the agility and flexibility to meet customer demands, adapt to rapid changes, operate at high efficiency and comply with requirements for risk management and protection 6 6

7 Advances in Data Center Cooling over the Last Five Years Wider ASHRAE allowable range Hot and Cold Aisle Containment Outside Air Economization EC/Variable Speed Fans Variable Capacity Compressors Row based cooling Intelligent cooling controls 7 7

8 Thermal Management Technology to Solve Customer Needs Efficiency / Economization Efficient Capital/Modular/Speed Solutions Control/Intelligence 8 Availability 8

9 Thermal Management Technology to Solve Customer Needs Efficiency / Economisation Higher Return Air & Chilled Water Temps, Variable Capacity, Aisle Control, Max Economisation Hours, New Technology Efficient Capital/Modular/Speed Solutions that will allow effective growth and use of Capital in Optimized Building Blocks, Lowest Max kw Solutions Control/Intelligence Engineered / Optimized, Ease of Connectivity, Custom Standard Configurations From the Unit, Aisle to the Whole Data Centre Visibility and Control 9 Availability Systems & Controls to Measure, Monitoring & Service to maintain the highest Availability 9

10 Energy Efficiency, Lower Operating Costs Technologies and approaches to reduce operational expenditures (OPEX) Focus on operational efficiency of data center environment Simple assessments help identify energy consumption 10 Opportunity: Reduce Cooling to under 15% or PUE < 1.20 Energy consumption in a typical data center Source: Energy Logic 10

11 The Data Centre World ASHRAE* defines different working ranges for temperature and humidity based upon installation and technology. This graph shows ASHRAE typical representation of predefined working envelopes ASHRAE* American Society of Heating, Refrigerating & Air Conditioning Engineers

12 The Data Centre World Typical Application: Legacy DC with Return Control and High Precision on Humidity Hardware: All Servers Temperature & Humidity: 20 C 25 C 40% 55% RH 12 12

13 The Data Centre World Typical Application: Legacy DC with Return Control and High Precision on Humidity Hardware: All Servers Temperature & Humidity: 20 C 25 C 40% 55% RH Typical Application: Current DC with Return or Supply Control and Humidity Control Hardware: All Servers Temperature & Humidity: 18 C 27 C 5.5DP 60% RH&15DP 13 13

14 The Data Centre World Typical Application: Legacy DC with Return Control and High Precision on Humidity Hardware: All Servers Temperature & Humidity: 20 C 25 C 40% 55% RH Typical Application: Current DC with Return or Supply Control and Humidity Control Hardware: All Servers Temperature & Humidity: 18 C 27 C 5.5DP 60% RH&15DP Typical Application: Data Centre with focus on Energy Savings and enlarged limits on Humidity Hardware: Enterprise servers, storage products Temperature & Humidity: 15 C 32 C 20% 80% RH Typical Application: Information and Technology Space or Office Hardware: Volume servers, storage products, pc, workstations Temperature & Humidity: 10 C 35 C 20% 80% RH

15 Chilled Water Evaporative Cooling Technology Direct Expansion Warehouse Type Data Centre Cooling Building Type Freecooling Chiller with ADIA Multi-story Building 15

16 How to Achieve Data Centre Thermal Management: 3 Main Cooling Technologies DIRECT EXPANSION Configuration Cooling Medium Typical Application Indoor units with compressors connected to an outdoor condenser Refrigerant Freecooling: pumped refrigerant, indirect with water or fresh air From 10kW to kW data centre CHILLED WATER Configuration Cooling Medium Indoor units with heat exchange, EC Fan, valves and controls connected to a Freecooling Chiller through large water pipes Water produced from a Freecooling chiller Freecooling: From the outdoor unit / fresh air cooling Typical Application Medium and large data centre from 0.1 to 5MW module 16 AIR to AIR ADIABATIC Configuration Cooling Medium Typical Application Outdoor unit connected in the perimeter of the building and recirculating the air from and to the data centre Fresh air + vaporized water Backup: either direct expansion or Chilled water Warehouse type data centre from 0.5MW upwards

17 17 Direct Expansion w/pumped Economiser First ever Pumped Refrigerant Economizer mode with operation down to a 1.05 p PUE Reliable and Low Maintenance Operation No Water usage or treatment No Outside Air or damper maintenance Instant automatic economizer changeover icom control manages the system Larger building blocks 80 to 150 kw for sites up to 3 MW Canberra 17 90% in Full Economization No Compressor Operation

18 How Higher Return Air Helps Economisation 24º C Return 30º C Return 35º C Return At 70% load and 30 C RAT, full economization is available at 10 C outdoor 40º C Return Deg C Outdoor Ambient Annual free-cooling hours increase at higher return air conditions and lower unit loads 18 Percentage of Annual Hours in Economisation Mode (@80% load) Location 30 C Return Air 35 C Return Air Sydney 16% 54% Melbourne 47% 80% Canberra 61% 90% 18

19 19 Climate Impact on Economisation Melbourne Sydney Perth Brisbane 19

20 20 Economisation needs Intelligent Controls Liebert EconoPhase Pump Speed Refrigerant Temperature Liebert MC Condenser Condenser Fan Speed Ambient Temperature Liebert DSE Indoor Unit Unit Capacity EconoPhase Unit Status Pump Head Liebert MC Unit Status Head Pressure Room Humidity Liebert icom Liebert DSE with icom Benefits: Maximizes free-cooling hours through automatic economizer transition control Minimizes power consumption by optimizing component operation for lowest total system power Provides built-in diagnostics to ensure proper system operation Provides interface to Liebert data centre management systems 20 Room Temperature Evaporator Fan Speed

21 Adiabatic FreeCooling Chillers Freecooling ADIABATIC PAD Adiabatic Cooling % Compressor Back-up

22 High Efficiency and High Availability Intelligent controls provide the most efficient operating mode for the chillers whilst also providing protection during extreme ambients (50C) or loss of water LOW TEMP FREECOOLING ADIABATIC FREECOOLING HYBRID COOLING HIGH TEMP ADIABATIC MECHANICAL COOLING 22 during water shortages SAFE MODE

23 23 Evaporative Cooling Applications 23

24 24 Liebert EVI Indirect Evaporative Air Handler Capacities from kw with DX or CW trim PUE <1.20 with No Outside Air Performance based on climate and Operating Temperatures Potential for lower Max kw Higher Tier applications require on site water storage or larger DX/CW 17 C Season Cooling Mode Dry Bulb Temp ( C) Wet Bulb Temp ( C) Liters Per Hour Cooling PUE 24 C Winter Dry C 24 C Spring/Fall Wet C Summer Wet w/ DX

25 Indirect Evaporative Cooling Where it Works Assuming 24 C Supply and 35 C Return Air Wetting Heat Exchanger + Trim Cooling 100% Load Dry Heat Exchanger Wetting Heat Exchanger 25

26 26 Liebert EVD Direct Evaporative Air Handler Capacities from kw with DX or CW trim PUE <1.10 requiring Outside Air (actual performance based on climate) Potential higher humidity and operating temperatures Lower Max kw Typically used in lower Tier applications 35 C 5 C 24 C 26

27 27 Direct Evaporative Cooling Customers Range Where it works ASHRAE Recommended Operations Most data centres will implement a dew point limit at or near the ASHRAE upper level of15 o C Hyperscale / Aggressive Operations 27

28 28 Liebert XD Primary or Supplemental Cooling Designed for High Density Localized cooling modules cooling at the source add on demand 100% sensible Pumped Refrigerant Works with any rack New Liebert XDR Back Of Cabinet Room Neutral No Fans (electrical) Flexible any rack Future economizer Energy saving +50% Liebert XDR 28

29 Modular Constructed Data Centre? Traditional Stick-Build Design Build Install Build = creating physical structure Install = adding mechanical/electrical plant and IT eqpt. Emerson Data Centre Container Solution Design Manufacture Install Manufacture = fabricating container in factory, including mechanical/electrical plant Install = placing container inside/outside a structure, connecting mechanical/electrical plant, adding IT eqpt. NBN Australia Data Centre 29 Modular Constructed Data Centre (MCDC) Design Manufacture Assemble Off-Site On-Site The MCDC Becomes the Building! 29

30 30 DCIM Data Centre Infrastructure Management SITE MANAGER 30

31 DCIM Evolution Roadmap 31 Capability What do I have? Basic Remote data access Ad hoc processes Limited tools Unclear roles Problems not understood Real-time data center What is it doing? Reactive Monitor / Alerts Status / Health views Little prioritization Tools are isolated Few standards Simple KPIs Problems understood What should I do? Value Proactive Real-time data Basic information models Policies defined Collaboration Holistic tools KPIs aligned to objectives Problems are anticipated Real-time, resilient data center How do I Improve? Optimized Predictive modeling Root cause analysis Automated policy and exception management Active identification of cost reduction Avoid problem situations Do it for me! Autonomic Automated policies Auto-Response to events Self-diagnosis / healing Tight integration to business processes 31

32 32 DCIM Intelligence Delivers Capacity Management and Thermal Visualization and More Intelligent sensors provide insight to optimize efficiency and capacity Capacity Stack Electrical power consumption Airflow Gross cooling capacity (ex CW) Delivered Net Sensible capacity Remaining Capacity Predictive Diagnostics Thermal Visualization 3D model of the data center showing the thermal conditions Produce 3D rotational view of data center floor and inventory Thermal visualization view of front/rear of IT racks 32

33 33 Wireless Sensors Can Help Wireless sensors support dynamic IT environments and provide the flexibility and benefits of monitoring and control of the cooling systems Offers lower deployment costs compared to fixed sensors Measurements include temperature, humidity, pressure, power Ultra low power consumption ensures long battery life (+5 years) Wireless Sensor Devices Wireless Gateway Control System 33

34 Thermal Management System Keys to a Successful Data Centre Design Resiliency OPEX Efficiency CAPEX Cost SLA Why? Drives improved reliability in controlled supply air temperatures to the Rack Containment Critical Means to driver for higher return air temperatures to the cooling unit Higher return air temperatures increase unit capacities to lower unit count Economization Reduced mechanical refrigeration energy Improved life (MTBF) Sustainable control of operating costs Adjust and optimize the cooling system to the IT load Control Networking for optimization, fault tolerance and information sharing Maintain operating condition (ASHRAE Guidelines) Intelligent Monitoring Means to verify optimal performance Anticipating / predicting critical issues that could impact reliability and costs Planning change and growth Time value of money, reduced waste of excess capacity 34 Scalable Design Takes advantage of latest technology as improvements come to market Speed of deployment 3

35 Emerson s Thermal Management Data Centre Product Portfolio Liebert HPC S Liebert HPC M Liebert HPC L Liebert PEX DX & CHW Liebert DSE Liebert AFC Building Free Cooling Chillers Liebert DM Room/Perimeter Cooling Liebert PCW Liebert PDX Digital Scroll Knürr DCL Knürr DCD Rack and In Row Liebert XDV Liebert HPS Liebert XDH Liebert CRV Evaporative Air Handlers/Room Cooling 35 35

AIRAH Presentation April 30 th 2014

AIRAH Presentation April 30 th 2014 Data Centre Cooling Strategies The Changing Landscape.. AIRAH Presentation April 30 th 2014 More Connections. More Devices. High Expectations 2 State of the Data Center, Emerson Network Power Redefining

More information

Liebert EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit

Liebert EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit Liebert EFC from 100 to 350 kw The Highly Efficient Indirect Evaporative Freecooling Unit Liebert EFC, the Highly Efficient Indirect Evaporative Freecooling Solution Emerson Network Power delivers innovative

More information

Center. September 2013

Center. September 2013 Emerson Network Power Thermal Management Cooling Overview Liebert Solutions for the Large Data Center September 2013 Agenda Thermal management customer requirements Liebert solutions for large data centers

More information

Analysis of data centre cooling energy efficiency

Analysis of data centre cooling energy efficiency Analysis of data centre cooling energy efficiency An analysis of the distribution of energy overheads in the data centre and the relationship between economiser hours and chiller efficiency Liam Newcombe

More information

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers CURBING THE COST OF DATA CENTER COOLING Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers OVERVIEW Compare Cooling Strategies in Free- Standing and In-Building

More information

Legacy Data Centres Upgrading the cooling capabilities What are the options?

Legacy Data Centres Upgrading the cooling capabilities What are the options? Legacy Data Centres Upgrading the cooling capabilities What are the options? Presentation Structure What is a Legacy Data Centre? What is CRAC cooling? ASHRAE Standards Overview Available Cooling Systems

More information

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency A White Paper from the Experts in Business-Critical Continuity TM Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency Executive Summary Energy efficiency

More information

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America 7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer

More information

National Grid Your Partner in Energy Solutions

National Grid Your Partner in Energy Solutions National Grid Your Partner in Energy Solutions National Grid Webinar: Enhancing Reliability, Capacity and Capital Expenditure through Data Center Efficiency April 8, 2014 Presented by: Fran Boucher National

More information

In Row Cooling Options for High Density IT Applications

In Row Cooling Options for High Density IT Applications In Row Cooling Options for High Density IT Applications By Ramzi Y. Namek, PE, LEED AP, BD+C; Director of Engineering 1 Users wishing to deploy high density IT racks have several In Row Cooling solutions

More information

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling Data Center Design Guide featuring Water-Side Economizer Solutions with Dynamic Economizer Cooling Presenter: Jason Koo, P.Eng Sr. Field Applications Engineer STULZ Air Technology Systems jkoo@stulz ats.com

More information

THE WORLD S MOST EFFICIENT DATA CENTER

THE WORLD S MOST EFFICIENT DATA CENTER THE WORLD S MOST EFFICIENT DATA CENTER HP POD 240a Ed Turkel Manager, WW HPC Marketing Hyperscale Business Unit 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject

More information

Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert

Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert Data Center Consolidation Trends & Solutions Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert Agenda Traditional Data Centers Drivers of a Changing Environment Alternate

More information

European Code of Conduct for Data Centre. Presentation of the Awards 2013

European Code of Conduct for Data Centre. Presentation of the Awards 2013 European Code of Conduct for Data Centre Presentation of the Awards 2013 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport 1 The Code of Conduct for Data Centre Results Started

More information

Excool Indirect Adiabatic and Evaporative Data Centre Cooling. World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

Excool Indirect Adiabatic and Evaporative Data Centre Cooling. World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling Excool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling Indirect Adiabatic and Evaporative Data Centre Cooling Solutions by

More information

Reference Guide: SmartDesign Approach: Common Data Center Challenges:

Reference Guide: SmartDesign Approach: Common Data Center Challenges: Smart Solutions Reference Guide Solutions For Business-Critical Continuity 1100kW Tier 3 With High Density Design Intelligent, Integrated Infrastructure for the Data Center Reference Guide: 1100kW Tier

More information

State of the Art Energy Efficient Data Centre Air Conditioning

State of the Art Energy Efficient Data Centre Air Conditioning - White Paper - State of the Art Energy Efficient Data Centre Air Conditioning - Dynamic Free Cooling - Release 2, April 2008 Contents ABSTRACT... 3 1. WHY DO I NEED AN ENERGY EFFICIENT COOLING SYSTEM...

More information

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions Free Cooling in Data Centers John Speck, RCDD, DCDC JFC Solutions Why this topic Many data center projects or retrofits do not have a comprehensive analyses of systems power consumption completed in the

More information

Defining Quality. Building Comfort. Precision. Air Conditioning

Defining Quality. Building Comfort. Precision. Air Conditioning Defining Quality. Building Comfort. Precision Air Conditioning Today s technology rooms require precise, stable environments in order for sensitive electronics to operate optimally. Standard comfort air

More information

STULZ Water-Side Economizer Solutions

STULZ Water-Side Economizer Solutions STULZ Water-Side Economizer Solutions with STULZ Dynamic Economizer Cooling Optimized Cap-Ex and Minimized Op-Ex STULZ Data Center Design Guide Authors: Jason Derrick PE, David Joy Date: June 11, 2014

More information

Indirect Evaporative Cooling (IDEC) Unit for Data Centers

Indirect Evaporative Cooling (IDEC) Unit for Data Centers Indirect Evaporative Cooling (IDEC) Unit for Data Centers NORTEK AIR SOLUTIONS Cool3 IDEC UNIT INDIRECT EVAPORATIVE COOLING The new Nortek Air Solutions Cool 3 IDEC unit is a proven approach for highly

More information

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: www.cruptime.com Uptime Racks: www.uptimeracks.com

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: www.cruptime.com Uptime Racks: www.uptimeracks.com Cooling Small Server Rooms Can Be Inexpensive, Efficient and Easy - Jim Magallanes Computer Room Uptime: www.cruptime.com Uptime Racks: www.uptimeracks.com Server Rooms Description & Heat Problem Trends

More information

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER DATA CENTERS 2009 IT Emissions = Aviation Industry Emissions Nations Largest Commercial Consumers of Electric Power Greenpeace estimates

More information

Minimising Data Centre Total Cost of Ownership Through Energy Efficiency Analysis

Minimising Data Centre Total Cost of Ownership Through Energy Efficiency Analysis Minimising Data Centre Total Cost of Ownership Through Energy Efficiency Analysis Sophia Flucker CEng MIMechE Ing Dr Robert Tozer MSc MBA PhD CEng MCIBSE MASHRAE Operational Intelligence Ltd. info@dc-oi.com

More information

Modular Data Centre. Flexible, scalable high performance modular data centre solutions. Data Centre Solutions...energy efficient by design

Modular Data Centre. Flexible, scalable high performance modular data centre solutions. Data Centre Solutions...energy efficient by design Data Centre Solutions...energy efficient by design Modular Data Centre Flexible, scalable high performance modular data centre solutions Creating an effective workspace environment The Modular Data Centre

More information

Future-Proof the Banking and Finance Data Center

Future-Proof the Banking and Finance Data Center Future-Proof the Banking and Finance Data Center Reinier Dungca Rey Perea Marketing Manager, Southeast Asia and North Asia Manager, Local Technical Support Emerson Network Power Emerson Network Power Philippines

More information

Economizer Fundamentals: Smart Approaches to Energy-Efficient Free-Cooling for Data Centers

Economizer Fundamentals: Smart Approaches to Energy-Efficient Free-Cooling for Data Centers A White Paper from the Experts in Business-Critical Continuity TM Economizer Fundamentals: Smart Approaches to Energy-Efficient Free-Cooling for Data Centers Executive Summary The strategic business importance

More information

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages Objectives Increase awareness of the types of economizers currently used for data centers Provide designers/owners with an overview of the benefits and challenges associated with each type Outline some

More information

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity Liebert Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment Precision Cooling For Business-Critical Continuity The Intelligent Data Center Cooling Solution: Liebert Trust the industry

More information

Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling

Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling Joshua Grimshaw Director of Engineering, Nova Corporation

More information

Energy Efficiency and Availability Management in Consolidated Data Centers

Energy Efficiency and Availability Management in Consolidated Data Centers Energy Efficiency and Availability Management in Consolidated Data Centers Abstract The Federal Data Center Consolidation Initiative (FDCCI) was driven by the recognition that growth in the number of Federal

More information

Elements of Energy Efficiency in Data Centre Cooling Architecture

Elements of Energy Efficiency in Data Centre Cooling Architecture Elements of Energy Efficiency in Data Centre Cooling Architecture Energy Efficient Data Center Cooling 1 STULZ Group of Companies Turnover 2006 Plastics Technology 400 Mio A/C Technology 200 Mio Total

More information

Precision Cooling for Business-Critical Continuity. Liebert PCW. Cool the Cloud

Precision Cooling for Business-Critical Continuity. Liebert PCW. Cool the Cloud Precision Cooling for Business-Critical Continuity Cool the Cloud Whether a data center houses three or 1000 IT racks, deployment of new technologies with high power densities are impacting the power and

More information

Ten Steps to Increasing Data Center Efficiency and Availability through Infrastructure Monitoring

Ten Steps to Increasing Data Center Efficiency and Availability through Infrastructure Monitoring Ten Steps to Increasing Data Center Efficiency and Availability through Infrastructure Monitoring A White Paper from the Experts in Business-Critical Continuity Summary The first decade of the 21st century

More information

VISIT 2010 Fujitsu Forum Europe 0

VISIT 2010 Fujitsu Forum Europe 0 VISIT 2010 Fujitsu Forum Europe 0 Virtualization & Automation Room 13a Shaping tomorrow with you. Green Data Center Services Martin Provoost Director, Data Centers and Networks, Fujitsu UK & Ireland 14:00

More information

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity SmartDesign Intelligent, Integrated Infrastructure For The Data Center Solutions For Business-Critical Continuity Prepare Your Data Center For What s Next Efficiency. Availability. Capacity. Control. One

More information

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment The Intelligent Data Center Cooling Solution: Liebert CRV Trust the industry leader in Precision Cooling to deliver

More information

Ten Steps to Increasing Data Center Efficiency and Availability through Infrastructure Monitoring

Ten Steps to Increasing Data Center Efficiency and Availability through Infrastructure Monitoring Ten Steps to Increasing Data Center Efficiency and Availability through Infrastructure Monitoring A White Paper from the Experts in Business-Critical Continuity Summary The first decade of the 21st century

More information

How to Save Over 60% on Cooling Energy Needed by a Data Center? The Roadmap from Traditional to Optimized Cooling

How to Save Over 60% on Cooling Energy Needed by a Data Center? The Roadmap from Traditional to Optimized Cooling How to Save Over 60% on Cooling Energy Needed by a Data Center? The Roadmap from Traditional to Optimized Cooling Abstract Data center managers are increasingly in search of methods and technologies for

More information

Technical Systems. Helen Bedford

Technical Systems. Helen Bedford Technical Systems in Data Centres Helen Bedford Technical Systems in Data Centres Overview Cooling IT and Peripheral Equipment Security: Access and Control Building Management System (BMS) Data Centre

More information

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings

More information

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,

More information

POWER. Your Partners in Availability POWER

POWER. Your Partners in Availability POWER Your Partners in Availability The Service Arm for All Liebert Products We have the industry-leading technical expertise, top onsite response times and the most sophisticated parts logistics in the industry.

More information

Datacenter Clarity LC for colocation owners and tenants. The Data Center Infrastructure Management (DCIM) solution from Siemens. siemens.

Datacenter Clarity LC for colocation owners and tenants. The Data Center Infrastructure Management (DCIM) solution from Siemens. siemens. Datacenter Clarity LC for colocation owners and tenants The Data Center Infrastructure (DCIM) solution from Siemens siemens.com/dcim Increased efficiency through Datacenter Clarity LC As organizations

More information

Overview of Green Energy Strategies and Techniques for Modern Data Centers

Overview of Green Energy Strategies and Techniques for Modern Data Centers Overview of Green Energy Strategies and Techniques for Modern Data Centers Introduction Data centers ensure the operation of critical business IT equipment including servers, networking and storage devices.

More information

Energy Efficient Data Centre at Imperial College. M. Okan Kibaroglu IT Production Services Manager Imperial College London.

Energy Efficient Data Centre at Imperial College. M. Okan Kibaroglu IT Production Services Manager Imperial College London. Energy Efficient Data Centre at Imperial College M. Okan Kibaroglu IT Production Services Manager Imperial College London 3 March 2009 Contents Recognising the Wider Issue Role of IT / Actions at Imperial

More information

Direct Fresh Air Free Cooling of Data Centres

Direct Fresh Air Free Cooling of Data Centres White Paper Introduction There have been many different cooling systems deployed in Data Centres in the past to maintain an acceptable environment for the equipment and for Data Centre operatives. The

More information

DataCenter 2020: first results for energy-optimization at existing data centers

DataCenter 2020: first results for energy-optimization at existing data centers DataCenter : first results for energy-optimization at existing data centers July Powered by WHITE PAPER: DataCenter DataCenter : first results for energy-optimization at existing data centers Introduction

More information

CUSTOMER EXPERIENCE CENTER

CUSTOMER EXPERIENCE CENTER v CUSTOMER EXPERIENCE CENTER ABOUT THE CUSTOMER EXPERIENCE CENTER MAKE YOUR DATA CENTER AS DYNAMIC AS YOUR BUSINESS Emerson Network Power continuously strives to provide the best solutions by working collaboratively

More information

Critical Infrastructure for the World s Leading Data Centers

Critical Infrastructure for the World s Leading Data Centers Critical Infrastructure for the World s Leading Data Centers 2 YOU MAY KNOW US BY OUR BRAND NAMES THE EXPERTISE OF MANY. THE POWER OF ONE. Nortek Air Solutions provides critical infrastructure for the

More information

Environmental Data Center Management and Monitoring

Environmental Data Center Management and Monitoring 2013 Raritan Inc. Table of Contents Introduction Page 3 Sensor Design Considerations Page 3 Temperature and Humidity Sensors Page 4 Airflow Sensor Page 6 Differential Air Pressure Sensor Page 6 Water Sensor

More information

Managing Data Centre Heat Issues

Managing Data Centre Heat Issues Managing Data Centre Heat Issues Victor Banuelos Field Applications Engineer Chatsworth Products, Inc. 2010 Managing Data Centre Heat Issues Thermal trends in the data centre Hot Aisle / Cold Aisle design

More information

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Dealing with Thermal Issues in Data Center Universal Aisle Containment Dealing with Thermal Issues in Data Center Universal Aisle Containment Daniele Tordin BICSI RCDD Technical System Engineer - Panduit Europe Daniele.Tordin@Panduit.com AGENDA Business Drivers Challenges

More information

European Code of Conduct for Data Centre. Presentation of the Awards 2016

European Code of Conduct for Data Centre. Presentation of the Awards 2016 European Code of Conduct for Data Centre Presentation of the Awards 2016 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport 1 The Code of Conduct for Data Centre Results European

More information

Interested in conducting your own webinar? Email webinars@bnpmedia.com

Interested in conducting your own webinar? Email webinars@bnpmedia.com Interested in conducting your own webinar? Email webinars@bnpmedia.com Improving Efficiencies by Integrating Data Center Systems August 30 th, 2012 Audio Abstract Presenter Info Slides Handouts Group Chat

More information

How To Run A Data Center Efficiently

How To Run A Data Center Efficiently A White Paper from the Experts in Business-Critical Continuity TM Data Center Cooling Assessments What They Can Do for You Executive Summary Managing data centers and IT facilities is becoming increasingly

More information

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS Air / Water / DX Cooled Cabinet Solutions Mini Data Centre All in One Solution: Where there is a requirement for standalone computing and communications, or highly

More information

Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre

Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre S. Luong 1*, K. Liu 2, James Robey 3 1 Technologies for Sustainable Built Environments, University of Reading,

More information

Data Center Infrastructure Management Managing the Physical Infrastructure for Greater Efficiency

Data Center Infrastructure Management Managing the Physical Infrastructure for Greater Efficiency Data Center Infrastructure Management Managing the Physical Infrastructure for Greater Efficiency Infrastructure Management & Monitoring for Business-Critical Continuity TM DATA CENTER INFRASTRUCTURE MANAGEMENT

More information

Infrastructure & Cities Sector

Infrastructure & Cities Sector Technical Article Infrastructure & Cities Sector Building Technologies Division Zug (Switzerland), October 18, 2011 Saving Energy in a Data Center A Leap of Faith? New guidelines from ASHRAE (American

More information

Revolutionizing Data Center Infrastructure Management

Revolutionizing Data Center Infrastructure Management Infrastructure Management & Monitoring for Business-Critical Continuity TM Revolutionizing Data Center Infrastructure Management The Trellis Platform A Real-Time Solution to Continuous Performance Improvement

More information

Liebert : The Right Cooling For IT Environments. Precision Cooling For Business-Critical Continuity

Liebert : The Right Cooling For IT Environments. Precision Cooling For Business-Critical Continuity Liebert : The Right Cooling For IT Environments Precision Cooling For Business-Critical Continuity New Challenges To IT System Uptime Many IT professionals are finding that dedicated precision cooling

More information

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia Prepared for the U.S. Department of Energy s Federal Energy Management Program

More information

Top 5 Trends in Data Center Energy Efficiency

Top 5 Trends in Data Center Energy Efficiency Top 5 Trends in Data Center Energy Efficiency By Todd Boucher, Principal Leading Edge Design Group 603.632.4507 @ledesigngroup Copyright 2012 Leading Edge Design Group www.ledesigngroup.com 1 In 2007,

More information

Data Center Solutions - The Containerized Evolution

Data Center Solutions - The Containerized Evolution Data Center Solutions - The Containerized Evolution Power IT Cooling 7 th Green Connected World Tsikogias Thanassis Data Centers Solutions Architect, IT Business Athens 2015 1 We are the global specialist

More information

HVAC Infrastructure Retrofit Solutions

HVAC Infrastructure Retrofit Solutions Kyoto Cooling Lunch & Learn David Belleville, APA LLC March 9, 2015 Owners choose APA solutions to: Rely on our 30+ years of delivering engineered solutions; HVAC Infrastructure Retrofit Solutions Insure

More information

Data Center Environments

Data Center Environments Data Center Environments ASHRAE s Evolving Thermal Guidelines By Robin A. Steinbrecher, Member ASHRAE; and Roger Schmidt, Ph.D., Member ASHRAE Over the last decade, data centers housing large numbers of

More information

How to Build a Data Centre Cooling Budget. Ian Cathcart

How to Build a Data Centre Cooling Budget. Ian Cathcart How to Build a Data Centre Cooling Budget Ian Cathcart Chatsworth Products Topics We ll Cover Availability objectives Space and Load planning Equipment and design options Using CFD to evaluate options

More information

Scalable. Affordable. Flexible. Fast.

Scalable. Affordable. Flexible. Fast. Modular Data Center Solutions Scalable. Affordable. Flexible. Fast. Build the data center you need today with the flexibility to meet tomorrow s challenges The only constant in business is change. Fluctuations

More information

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Intel Intelligent Power Management Intel How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Power and cooling savings through the use of Intel

More information

Data Center Design and Energy Management

Data Center Design and Energy Management Agenda EasyStreet Online Services, Inc. Data Center Design and Energy Management Introduction to EasyStreet Speaker Bio EasyStreet Sustainability Data Center 1 (Retrofit completed May 2010) Data Center

More information

Data Center Cooling Critical Facility & Infrastructure Optimization. Presented by. Greg Stover SVP NER Data Corporation

Data Center Cooling Critical Facility & Infrastructure Optimization. Presented by. Greg Stover SVP NER Data Corporation Data Center Cooling Critical Facility & Infrastructure Optimization Presented by Greg Stover SVP NER Data Corporation About NER Data Corporation Data Center Infrastructure Optimization NER has been a leading

More information

Business white paper. A new approach to industrialized IT. HP Flexible Data Center

Business white paper. A new approach to industrialized IT. HP Flexible Data Center Business white paper A new approach to industrialized IT HP Flexible Data Center Table of contents 4 Introduction 4 Levels of modularity 5 What is HP Flexible DC? 5 HP Flexible DC features 6 The core-and-quadrant

More information

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise A White Paper from the Experts in Business-Critical Continuity Executive Summary Today s data centers are changing rapidly,

More information

Protecting Our Information, Protecting Our Resources

Protecting Our Information, Protecting Our Resources Solutions For Business-Critical Continuity Protecting Our Information, Protecting Our Resources Energy Efficient Power And Cooling For IT And Telecommunications Network Infrastructures The Challenge You

More information

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw Knürr DCL Modular Rack Cooling from 6 kw to 60 kw Emerson Network Power Business-Critical Continuity so your success continues! Core competencies AC Power Connectivity DC Power Embedded Computing Embedded

More information

DATA CENTER ASSESSMENT SERVICES

DATA CENTER ASSESSMENT SERVICES DATA CENTER ASSESSMENT SERVICES ig2 Group Inc. is a Data Center Science Company which provides solutions that can help organizations automatically optimize their Data Center performance, from assets to

More information

High-density modular data center making cloud easier. Frank Zheng Huawei

High-density modular data center making cloud easier. Frank Zheng Huawei High-density modular data center making cloud easier Frank Zheng Huawei 2012-10-10 Content 1 2 3 4 Cloud s impact to data center Concerns of DC construction 4S DC making cloud easier Success stories Cloud?

More information

APC by Schneider Electric

APC by Schneider Electric APC by Schneider Electric Energy Efficiency - The Green Power Solution James Taylor Business Development manager, UK APC by Schneider Electric The Efficient Enterprise Components Close Coupled Cooling

More information

The Use of Fresh Air in the Data Centre

The Use of Fresh Air in the Data Centre The Use of Fresh Air in the Data Centre White paper of a round table debate by industry experts on this key topic. Hosted by Keysource with participants including the Uptime Institute. Sophistication Through

More information

Data Center Infrastructure Management Managing the Physical Infrastructure for Greater Efficiency

Data Center Infrastructure Management Managing the Physical Infrastructure for Greater Efficiency Data Center Infrastructure Management Managing the Physical Infrastructure for Greater Efficiency Infrastructure Management & Monitoring for Business-Critical Continuity TM DATA CENTER INFRASTRUCTURE MANAGEMENT

More information

A Blueprint for a Smarter Data Center Data Center Services helps you respond to change

A Blueprint for a Smarter Data Center Data Center Services helps you respond to change Bret W. Lehman, PE GTS Site and Facilities Services March 25, 2011 A Blueprint for a Smarter Data Center Data Center Services helps you respond to change 2011 IBM Corporation Change is accelerating IT

More information

Green Data Centre Design

Green Data Centre Design Green Data Centre Design A Holistic Approach Stantec Consulting Ltd. Aleks Milojkovic, P.Eng., RCDD, LEED AP Tommy Chiu, EIT, RCDD, LEED AP STANDARDS ENERGY EQUIPMENT MATERIALS EXAMPLES CONCLUSION STANDARDS

More information

Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie

Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie Mukesh Khattar, Energy Director, Oracle National Energy Efficiency Technology Summit, Sep. 26, 2012, Portland, OR Agenda

More information

Microsoft Technology Center: Philadelphia

Microsoft Technology Center: Philadelphia A Customer Success from the Experts in Business-Critical Continuity TM. Background Microsoft Technology Center: Philadelphia Microsoft Technology Centers are collaborative, state-of-the-art facilities

More information

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures Data Realty Colocation Data Center Ignition Park, South Bend, IN Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures Project Overview Data Realty is a data center service provider for middle

More information

Blade Server & Data Room Cooling Specialists

Blade Server & Data Room Cooling Specialists SURVEY I DESIGN I MANUFACTURE I INSTALL I COMMISSION I SERVICE SERVERCOOL An Eaton-Williams Group Brand Blade Server & Data Room Cooling Specialists Manufactured in the UK SERVERCOOL Cooling IT Cooling

More information

Paul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA

Paul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA Paul Oliver Sales Director Paul Oliver, Airedale Tom Absalom, JCA Airedale an overview 25,000m 2 UK premier test centre 450 staff Global distribution A Modine company Modine centre of excellence Airedale

More information

News in Data Center Cooling

News in Data Center Cooling News in Data Center Cooling Wednesday, 8th May 2013, 16:00h Benjamin Petschke, Director Export - Products Stulz GmbH News in Data Center Cooling Almost any News in Data Center Cooling is about increase

More information

The Effect of Data Centre Environment on IT Reliability & Energy Consumption

The Effect of Data Centre Environment on IT Reliability & Energy Consumption The Effect of Data Centre Environment on IT Reliability & Energy Consumption Steve Strutt EMEA Technical Work Group Member IBM The Green Grid EMEA Technical Forum 2011 Agenda History of IT environmental

More information

Data Centre Cooling Technologies. Jon Pettitt, EMEA DataCenter Business Development Manager

Data Centre Cooling Technologies. Jon Pettitt, EMEA DataCenter Business Development Manager Data Centre Cooling Technologies 1 Jon Pettitt, EMEA DataCenter Business Development Manager Munters Group Key facts 3.000 Employees 30 Countries Turnover of 470 M HQ in Sweden Global DC Support 25+ Data

More information

FEAR Model - Review Cell Module Block

FEAR Model - Review Cell Module Block F.E.A.R. Returns: 5 Steps Toward Data Center Efficiency Today Objectives Benefits for ITS professionals Brief review of the FEAR data center Define data center efficiency Link efficiency to the FEAR data

More information

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS International Telecommunication Union ITU-T TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU Technical Paper (13 December 2013) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES

More information

Energy Efficient Cooling Solutions for Data Centers

Energy Efficient Cooling Solutions for Data Centers A White Paper from the Experts in Business-Critical Continuity TM Energy Efficient Cooling Solutions for Data Centers Introducing an Emerson Network Power tool for evaluating cooling system total cost

More information

BCA-IDA Green Mark for Existing Data Centres Version EDC/1.0

BCA-IDA Green Mark for Existing Data Centres Version EDC/1.0 BCA-IDA Green Mark for Existing Data Centres Version EDC/1.0 To achieve GREEN MARK Award Pre-requisite Requirement All relevant pre-requisite requirements for the specific Green Mark Rating are to be complied

More information

NetApp Data Center Design

NetApp Data Center Design NetApp Data Center Design Presentation for SVLG Data Center Efficiency Summit November 5, 2014 Mark Skiff, PE, CEM, CFM Director, IT Data Center Solutions Data Center Design Evolution Capacity Build Cost

More information

White Paper. Data Center Containment Cooling Strategies. Abstract WHITE PAPER EC9001. Geist Updated August 2010

White Paper. Data Center Containment Cooling Strategies. Abstract WHITE PAPER EC9001. Geist Updated August 2010 White Paper Data Center Containment Cooling Strategies WHITE PAPER EC9001 Geist Updated August 2010 Abstract Deployment of high density IT equipment into data center infrastructure is now a common occurrence

More information

How To Find A Sweet Spot Operating Temperature For A Data Center

How To Find A Sweet Spot Operating Temperature For A Data Center Data Center Operating Temperature: The Sweet Spot A Dell Technical White Paper Dell Data Center Infrastructure David L. Moss THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL

More information

Maximizing Data Center Efficiency, Capacity and Availability through Integrated Infrastructure

Maximizing Data Center Efficiency, Capacity and Availability through Integrated Infrastructure Maximizing Data Center Efficiency, Capacity and Availability through Integrated Infrastructure Efficiencies and Cost Benefits Intrinsic to Integrated Infrastructure Solutions A White Paper from the Experts

More information

CANNON T4 MODULAR DATA CENTRE HALLS

CANNON T4 MODULAR DATA CENTRE HALLS CANNON T4 MODULAR DATA CENTRE HALLS Halve up-front investment, use a Modular fit out approach Highly efficient, Low PUE, Scalable system with reduced Capex and Opex Turnkey solutions available complete,

More information