Exterior Research & Design, L.L.C. Building Science and Envelope Consultants

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Exterior Research & Design, L.L.C. Building Science and Envelope Consultants"

Transcription

1 Exterior Research & Design, L.L.C. Building Science and Envelope Consultants Certificate of Authorization #9503 Evaluation Report Evaluation of R-Mer Span and R-Mer Loc Structural Metal Roofing Systems for Florida Product Approval #FL3723 Prepared for: The Garland Company, Inc East 91 st Street Cleveland, OH Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No Florida DCA ANE1983 Date of Issuance: November 19, 2004 ERD East: 2 Mattoon Road Waterbury, CT Voice (203) Fax (203) Main Office: th Avenue W Seattle, WA Voice (206) Fax (206)

2 Evaluation Report The Garland Company, Inc., FL3723 Date of Issuance: 11/19/04 Certificate of Page 2 of 3 Authorization #9503 Applicant: Product Category: Sub-Category: Evaluation Method: Compliance Statement: The Garland Company, Inc East 91 st Street Cleveland, OH Structural Components Roof Method 1: Products specifically addressed in the FBC through performance criteria and standardized testing or comparative rational analysis methods. R-Mer Span and R-Mer Loc structural metal roof systems, as produced by The Garland Company, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Standards: Section Property Standard Year Wind UL (rev 1995) Weathering ASTM G Impact FM (amd 1992) Fire UL Physicals ASTM A653, A792, B Physicals ASTM A653, A792, B Product Description: Name Type Width R-Mer Span Steel, gauge Aluminum, to , 16 or 18 R-Mer Loc Steel, gauge Aluminum, to , 16 or 18 Quality Assurance Documentation: 1. Listing through Underwriters Laboratories, Inc. (QUA 1743). Continued QA documentation comes in the form of the UL Mark on all product containers. 2. Non-Garland products shall be manufactured under a quality assurance program administered by a Florida DCA Approved Quality Assurance Entity, and materials and/or packaging shall carry the appropriate labeling from the Quality Assurance Entity. 3. All testing forming the basis of this report was conducted in full accordance with the requirements of the Florida Building Code. System testing was conducted using full-scale test specimens using the appropriate test standard. Installation Requirements: R-Mer Span and R-Mer Loc shall be installed in accordance with Garland published installation instructions, subject to the Limitations / Conditions of Use noted below. Details are attached in Appendices 1 and 2. ERD East: 2 Mattoon Road Waterbury, CT Voice (203) Fax (203) Main Office: th Avenue W Seattle, WA Voice (206) Fax (206)

3 Evaluation Report The Garland Company, Inc., FL3723 Date of Issuance: 11/19/04 Certificate of Page 3 of 3 Authorization #9503 Limitations / Conditions of Use: 1. This report is not for use in the High Velocity Hurricane Zones. 2. For fire classifications, refer to a current Approved Roofing Materials Directory. 3. This Evaluation Report is limited to the roof panel and its connecting clips. The structural adequacy of all other structural components (beams, columns, purlins, etc.) shall be verified by the structural plans examiner of the building department. The metal roof panels shall not be designed to act as a diaphragm. 4. Attachment requirements for wind load resistance are set forth in Appendices 1 and 2. The maximum span / design pressure for the selected assembly shall meet or exceed those determined in accordance with FBC Chapter 16 for all pressure zones. The maximum listed spans shall not be exceeded. Certification of Independence: 1. ERD East does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. ERD East is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. Continued Compliance: Evaluation for compliance is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify ERD if the product changes or the referenced Quality Assurance documentation changes. Respectfully submitted, Robert Nieminen, P.E. Florida Reg. No General Manager, ERD East ERD East: 2 Mattoon Road Waterbury, CT Voice (203) Fax (203) Main Office: th Avenue W Seattle, WA Voice (206) Fax (206)

4 ERD Evaluation Report No Date of Issuance: November 19, 2004 APPENDIX 1 Load/Span Limitations & Detail Drawings R-Mer Loc System

5 Certificate of Authorization #9503 Evaluation Report The Garland Company, Inc. Date of Issuance: 11/19/04 Appendix 1: Load/Span Limitations & Details, R-Mer Loc R-MER LOC Slope Range: Purlins: Insulation: Thermal Spacer: Metal Panels: Clips: Fasteners: Load / Span Limitations: 1½:12 or greater (By Others) meeting the structural requirements of the project. (Optional) Any compressible blanket insulation, 6 in. max. thickness before compression, or foamed plastic (rigid insulation), 1 to 4 in thick. (Optional) Nominal 1 x 4 in. wood or 1 x 3 in. polystyrene strips over purlins. Continuous when blanket insulation exceeds 4 in. max. thickness before compression. 24 or 22 ga steel, max. 18-inch wide or or inch aluminum panels, max. 12-inch wide with 1¾-inch high ribs. Panels shall be continuous over two or more spans. 18 ga. coated or stainless steel clips measuring 3-inch long by 1-3/8-inch high Two ¼ x 3 inch long self-tapping, hex-head, plated or stainless steel screws without washers per clip. Panel Material Max. Span R-Mer Loc Aluminum 48-inch Max. Design Pressure + 60 psf R-Mer Loc 12, 16 or ga. steel 48-inch + 56 psf R-Mer Loc 12, 16 or ga. steel 60-inch + 56 psf

6

7

8

9

10

11 ERD Evaluation Report No Date of Issuance: November 19, 2004 APPENDIX 2 Load/Span Limitations & Detail Drawings R-Mer Span System

12 Certificate of Authorization #9503 Evaluation Report The Garland Company, Inc. Date of Issuance: 11/19/04 Appendix 2: Load/Span Limitations & Details, R-Mer Span R-MER SPAN - ALUMINUM Slope Range: Purlins: Insulation: Thermal Spacer: Metal Panels: Clips: Fasteners: Load / Span Limitations: ¼:12 or greater (By Others) meeting the structural requirements of the project. (Optional) Any compressible blanket insulation, 6 in. max. thickness before compression, or foamed plastic (rigid insulation), 1 to 4 in thick. (Optional) Nominal 1 x 4 in. wood or 1 x 3 in. polystyrene strips over purlins. Continuous when blanket insulation exceeds 4 in. max. thickness before compression or inch aluminum panels, max. 18-inch wide with 2-3/8-inch high seams. Panels shall be continuous over three or more spans. 16 ga. coated or stainless steel clips measuring 5-3/8-inch long by 2-5/8-inch high Two ¼-14 x 1½ inch long self-tapping, hex-head, plated or stainless steel screws without washers per clip. See Following Pages

13

14

15

16

17

18

19

20

21

22

23

24 Certificate of Authorization #9503 Evaluation Report The Garland Company, Inc. Date of Issuance: 11/19/04 Appendix 2: Load/Span Limitations & Details, R-Mer Span R-MER SPAN - STEEL Slope Range: Purlins: Insulation: Thermal Spacer: Metal Panels: Clips: Fasteners: Load / Span Limitations: ¼:12 or greater (By Others) meeting the structural requirements of the project. (Optional) Any compressible blanket insulation, 6 in. max. thickness before compression, or foamed plastic (rigid insulation), 1 to 4 in thick. (Optional) Nominal 1 x 4 in. wood or 1 x 3 in. polystyrene strips over purlins. Continuous when blanket insulation exceeds 4 in. max. thickness before compression. 24 or 22 ga steel, max. 18-inch wide with 2-3/8-inch high seams. Panels shall be continuous over three or more spans. 16 ga. coated or stainless steel clips measuring 5-3/8-inch long by 2-5/8-inch high Two ¼-14 x 1½ inch long self-tapping, hex-head, plated or stainless steel screws without washers per clip. See Following Pages

25

26

27

28

29

30

31

32

33

34

35

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590

More information

DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 41 13 METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 41 13 METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC 0 ICC ES Report ICC ES (800) 423 687 (62) 699 043 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3422 Reissued 09/201 This report is subject to renewal 09/2016. DIVISION: 07 00 00 THERMAL AND

More information

PERFORMANCE TEST REPORT. Rendered to: ARCHITECTURAL METAL SOLUTIONS, INC.

PERFORMANCE TEST REPORT. Rendered to: ARCHITECTURAL METAL SOLUTIONS, INC. PERFORMANCE TEST REPORT Rendered to: ARCHITECTURAL METAL SOLUTIONS, INC. SERIES/MODEL: AMS ARMOR-LOCK PRODUCT TYPE: STANDING SEAM METAL ROOF PANEL SYSTEM Report No: 97123.02-901-44 Test Date: 05/17/10

More information

Construction No. 90 Uplift - Class 90 or 30 Fire Not Investigated

Construction No. 90 Uplift - Class 90 or 30 Fire Not Investigated www.mbci.com Construction No. 90 Uplift - Class 90 or 30 Fire Not Investigated 1. Metal Roof Deck Panels* No. 24 MSG min gauge coated steel, max width 16 in. Panels continuous over two or more spans. End

More information

Fire Resistance Bulletin

Fire Resistance Bulletin New 1-hr Rated Exterior Wall Assembly Includes Allowances for Various Insulation Options and Much Wider Maximum Girt Spacing Under the auspices of the MBMA Committee on Fire Protection and Related Insurance

More information

CF-Mesa, CF-Light Mesa, CF-Flute, CF-Metl-Plank, CF-Striated, CF-Santa Fe, CF-Architectural Flat, CF...

CF-Mesa, CF-Light Mesa, CF-Flute, CF-Metl-Plank, CF-Striated, CF-Santa Fe, CF-Architectural Flat, CF... Building Insulations - Walls and Ceilings (FM Approval Numbers 4411, 4651, 4880, 4881, 4882) Insulating materials may occur in building construction to reduce heat or sound transmission through a wall,

More information

http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wgevxqwtdquracbevcbdm...

http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wgevxqwtdquracbevcbdm... Florida Building Code Online http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wgevxqwtdquracbevcbdm... Page 1 of 2 3/23/2016 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats

More information

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS ROOFING APPLICATION STANDARD (RAS) No. 133 STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS 1. Scope 1.1 This application standard has been developed to provide consistent information for the

More information

Nucor VR16 II TM Vertical Rib Standing Seam Roof System

Nucor VR16 II TM Vertical Rib Standing Seam Roof System Nucor VR16 II TM Vertical Rib Standing Seam Ro System www.nucorbuildingsystems.com Nucor VR16 II Vertical Rib Standing Seam Ro Perfect for the Marketplace The Nucor Building Systems VR16 II Ro Panel is

More information

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B9460.01-109-18. Rendered to: CAPTIVEAIRE, INC. Blue Bell, Pennsylvania

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B9460.01-109-18. Rendered to: CAPTIVEAIRE, INC. Blue Bell, Pennsylvania Architectural Testing MIAMI-DADE COUNTY PERFORMANCE TEST REPORT Report No.: B9460.01-109-18 Rendered to: CAPTIVEAIRE, INC. Blue Bell, Pennsylvania PRODUCT TYPE: Roof Mounted Exhaust Fan SERIES/MODEL: CASRE

More information

SCHULTE BUILDING SYSTEMS, INC.

SCHULTE BUILDING SYSTEMS, INC. BELIEVE IT OR NOT. The following recognized certifications and listings have been earned: When you look at most metal roofs on the market today, you re looking at systems that rely on technology that s

More information

A. Section Thermal and Moisture Protection. D. Section Operation and Maintenance of Thermal and Moisture Protection.

A. Section Thermal and Moisture Protection. D. Section Operation and Maintenance of Thermal and Moisture Protection. -------------------------------------------------------------------------------------------------------------------------------- Firestall Roof Deck Architectural Specifications CSI Section 07 --------------------------------------------------------------------------------------------------------------------------------

More information

CHAPTER 7: Building Systems ROOFING SYSTEMS

CHAPTER 7: Building Systems ROOFING SYSTEMS ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen

More information

ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC

ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT Rendered to: BEKAERT SPECIALTY FILMS, LLC SERIES/MODEL: Panorama 8-mil Film PRODUCT TYPE: Fixed Window with Applied Film This

More information

Thermal Systems Design Guide

Thermal Systems Design Guide THERMAL SYSTEMS Thermal Systems Design Guide Thermalguard & Vapourguard 32 Thermalguard BEHLEN Thermal Assemblies are designed to optimize the thermal performance of any steel structure. Easily combined

More information

Metal Roofing Practical Design

Metal Roofing Practical Design Metal Roofing Practical Design Metal Roofing Practical Design Learning Outcomes Minimum Requirements Design Resources Low Slope Metal Roofing Design Details Continuously Insulated (Ci) Systems Minimum

More information

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in one year.

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in one year. ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-900* Reissued March, 20 This report is subject to renewal in one year. A Subsidiary of the International Code Council DIVISION:

More information

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023 Specifications Preformed Metal Wall and Roof Panels Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023 Section 07410 Preformed Metal Wall and Roof Panels Structural

More information

THERMAL SPACERS IMPROVE ROOF INSULATION PERFORMANCE OF METAL BUILDINGS. Harold J. Waite Member ASHRAE. Marvin K. Snyder Member ASHRAE

THERMAL SPACERS IMPROVE ROOF INSULATION PERFORMANCE OF METAL BUILDINGS. Harold J. Waite Member ASHRAE. Marvin K. Snyder Member ASHRAE S IMPROVE ROOF PERFORMANCE OF METAL BUILDINGS Harold J. Waite Member ASHRAE Marvin K. Snyder Member ASHRAE Pre-engineered metal building systems are being increasingly used to construct the one and two

More information

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES Scope 1.1.

More information

Standing Seam Roof Systems

Standing Seam Roof Systems Standing Seam Roof Systems REAL PEOPLE. REAL PRODUCTS. REAL SOLUTIONS. www.a-s.com Building Benefits You Can Expect From A&S Materials Standing Seam roof panels weigh a relatively modest 11/2 pounds per

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: CUSTOM-BILT METALS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: CUSTOM-BILT METALS 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-2048 Reissued 03/2015 This report is subject to renewal 03/2017 DIVISION: 07 00 00 THERMAL AND

More information

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: NORSE, INC.

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: NORSE, INC. Architectural Testing ASTM E 1886 and ASTM E 1996 TEST REPORT Rendered to: NORSE, INC. SERIES/MODEL: Flush Mount/Surface Mount PRODUCT TYPE: Hurricane Shutter Fastening System This report contains in its

More information

FM 4473 TEST REPORT. Rendered to: VTECH INDUSTRIES, LLP. SERIES/MODEL: 4 x 4 CMC Hurricane PRODUCT TYPE: Skylight

FM 4473 TEST REPORT. Rendered to: VTECH INDUSTRIES, LLP. SERIES/MODEL: 4 x 4 CMC Hurricane PRODUCT TYPE: Skylight FM 4473 TEST REPORT Rendered to: VTECH INDUSTRIES, LLP SERIES/MODEL: 4 x 4 CMC Hurricane PRODUCT TYPE: Skylight Report No.: 92240.01-801-75 Test Date: 08/27/09 Report Date: 08/31/09 Expiration Date: 08/27/13

More information

SECTION STANDING SEAM METAL ROOFING

SECTION STANDING SEAM METAL ROOFING PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 41 13 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Use for roofing sloped 1 in 4 (3 in/ft) or greater. 3. Delete between // // if not applicable

More information

UL 580 TEST REPORT. Rendered to: ARMSTRONG WORLD INDUSTRIES. SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC

UL 580 TEST REPORT. Rendered to: ARMSTRONG WORLD INDUSTRIES. SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC UL 580 TEST REPORT Rendered to: ARMSTRONG WORLD INDUSTRIES SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC Report No.: Test Dates: 12/14/09 Through: 12/22/09 Report Date: 03/12/10 Expiration

More information

metal Duil~ing manufacturers Association

metal Duil~ing manufacturers Association metal Duil~ing manufacturers Association ApplicatiDns metal Building Systems Conventional Buildings Retrofit Roofing Projects l~e Perfect Cover.One of the most important technological advances in building

More information

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services ATI Evaluation Service A Division of Architectural Testing Certification Services Subject to Renewal: 07/13/12 Issued: 07/13/10 Visit for current status Page 1 of 10 Solatube International, Inc 2210 Oak

More information

ICC-ES Evaluation Report Reissued July 1, 2009 This report is subject to re-examination in two years.

ICC-ES Evaluation Report Reissued July 1, 2009 This report is subject to re-examination in two years. ICC-ES Evaluation Report ESR-1566* Reissued July 1, 2009 This report is subject to re-examination in two years. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council

More information

INDACO METALS, LLC. RIGID BUILDING SYSTEMS 3 AMERICAN WAY, SHAWNEE, OKLA PH: FAX:

INDACO METALS, LLC. RIGID BUILDING SYSTEMS 3 AMERICAN WAY, SHAWNEE, OKLA PH: FAX: METAL BUILDING INFORMATION GUIDE This bulletin is designed to aid the metal building buyer in the purchase of a rigid building system. What is a rigid building? A rigid building is a building that most

More information

PERFORMANCE TEST REPORT. Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems

PERFORMANCE TEST REPORT. Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems PERFORMANCE TEST REPORT Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems Summary of Results Title Test Specimen #1 Test Specimen #2 Air Infiltration

More information

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.

More information

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: CORAL ARCHITECTURAL PRODUCTS

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: CORAL ARCHITECTURAL PRODUCTS Architectural Testing ASTM E 1886 and ASTM E 1996 TEST REPORT Rendered to: CORAL ARCHITECTURAL PRODUCTS SERIES/MODEL: PW 256 with Door Openings PRODUCT TYPE: Aluminum Impact Resistant Curtain Wall System

More information

Florida Building Code Approval

Florida Building Code Approval Florida Building Code Approval GAF-Elk Roof Underlayments Updated 10/13/09 Your Best and Safest Choice Quality You Can Trust Since 1886! Florida Building Code Online http://floridabuilding.org/pr/pr_app_dtl.aspx?param=wgevxqwtdqtbnbey5v%2boq...

More information

ISO Types 1-6: Construction Code Descriptions

ISO Types 1-6: Construction Code Descriptions ISO 1 Frame (combustible walls and/or roof) Class 1B Buildings where the exterior walls are wood or other combustible materials, including construction where the combustible materials are combined with

More information

APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE

APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT NCE Table Application Type Description Page 1A-1 Wood New, Reroof (Tear-Off), Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 4 1A-2

More information

Florida Building Code, 5 th Edition SHINGLE ROOFING

Florida Building Code, 5 th Edition SHINGLE ROOFING Florida Building Code, 5 th Edition SHINGLE ROOFING Date Issued/Updated: July 6, 2015 This bulletin addresses the current Building Code roofing and re roofing requirements for shingle roofing systems.

More information

DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 32 16 CONCRETE ROOF TILES REPORT HOLDER:

DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 32 16 CONCRETE ROOF TILES REPORT HOLDER: 0 ICC ES Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted ESR 1900 Reissued 03/2016 This report is subject to renewal 03/2017. DIVISION: 07 00 00 THERMAL

More information

Guide Specifications. Metl-Span CFR Roof Panels For Commercial & Industrial Buildings PART 1 GENERAL Master Format Section

Guide Specifications. Metl-Span CFR Roof Panels For Commercial & Industrial Buildings PART 1 GENERAL Master Format Section Guide Specifications 2012 Master Format Section 07 41 13.23 Metl-Span CFR Roof Panels For Commercial & Industrial Buildings PART 1 GENERAL 1.1 Work Included A. Pre-insulated CFR Standing Seam Roof Panels

More information

LISTING INFORMATION OF Alucoil - larson by Alucoil FR 4 mm and 6 mm ACM Panels SPEC ID: 29074. Alucoil North America LLC 1976 Joe Rogers Jr Blvd

LISTING INFORMATION OF Alucoil - larson by Alucoil FR 4 mm and 6 mm ACM Panels SPEC ID: 29074. Alucoil North America LLC 1976 Joe Rogers Jr Blvd LISTING INFORMATION OF Alucoil - larson by Alucoil FR 4 mm and 6 mm ACM Panels SPEC ID: 29074 Alucoil North America LLC 1976 Joe Rogers Jr Blvd Manning, SC 29102 This report is for the exclusive use of

More information

Laboratory Report P12850.03.09. Simulated Wind Uplift Testing of Adhered Single-Ply Roofing Systems in accordance with FM Standard 4470, Appendix C

Laboratory Report P12850.03.09. Simulated Wind Uplift Testing of Adhered Single-Ply Roofing Systems in accordance with FM Standard 4470, Appendix C Simulated Wind Uplift Testing of Adhered Single-Ply Roofing Systems in accordance with FM Standard 4470, Appendix C Prepared for: 2100 River Edge Parkway, Suite 175 Atlanta, GA 30328 Date of Issuance:

More information

REFLECTIVE INSULATION, RADIANT BARRIERS,

REFLECTIVE INSULATION, RADIANT BARRIERS, REFLECTIVE INSULATION, RADIANT BARRIERS, AND INTERIOR RADIATION CONTROL COATINGS FOR USE IN PRE-ENGINEERED METAL BUILDINGS Technical Bulletin #107 Scope: In both the United States and Canada there is significant

More information

REPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE

REPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-2134 Reissued 12/2015 This report is subject to renewal 12/2016. DIVISION: 07 00 00 THERMAL

More information

TABLE OF CONTENTS COMPANY INFORMATION HOUSING MODELS CONNECTION DETAILS ENERGY STAR PHOTOS SPECIFICATIONS COMPANY BROCHURES

TABLE OF CONTENTS COMPANY INFORMATION HOUSING MODELS CONNECTION DETAILS ENERGY STAR PHOTOS SPECIFICATIONS COMPANY BROCHURES PANELIZED HOUSING 4650 Lyons Technology Parkway, Coconut Creek, Florida 3073 954.949.3200 - Fax 954.949.3201 www.elitealuminum.com - info@elitealuminum.com TABLE OF CONTENTS 1) 2) 3) 4) 5) 6) 7) COMPANY

More information

SECTION 07400 STANDING SEAM METAL ROOF

SECTION 07400 STANDING SEAM METAL ROOF SECTION 07400 STANDING SEAM METAL ROOF PART 1 - GENERAL 1.01 SECTION INCLUDES A. Work described in this section includes pre-formed standing seam metal roofing system complete with clips, perimeter and

More information

General Specifications for Golden Giant Building Systems S. Vision Dr. P.O. Box 389 Kenton, Ohio PH:

General Specifications for Golden Giant Building Systems S. Vision Dr. P.O. Box 389 Kenton, Ohio PH: General Specifications for Golden Giant Building Systems 13300 S. Vision Dr. P.O. Box 389 Kenton, Ohio 43326 PH: 1.800.828.1209 Revised 4/19/2010 1 General Specifications 1. Building Type: The Pre-Engineered

More information

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks 174.6 FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks 174.6 FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3. Pages identified with the NMBS Logo as shown above, have been produced by NMBS to assist specifiers and consumers in the application of New Millennium Building Systems Deck products. Pages identified with

More information

FIRE-RESISTANCE RATINGS WITH STEEL JOISTS

FIRE-RESISTANCE RATINGS WITH STEEL JOISTS FIRE-RESISTANCE RATINGS WITH STEEL JOISTS The Underwriters Laboratories (U.L.) Fire Resistance Directory lists hundreds of assemblies their fire resistance ratings. The Specifying Professional can choose

More information

Metal Roof Systems in High-Wind Regions

Metal Roof Systems in High-Wind Regions Metal Roof Systems in High-Wind Regions http://www.fema.gov HURRICANE IKE RECOVERY ADVISORY Purpose: To recommend practices for designing and installing metal roof systems that will enhance wind resistance

More information

CERTIFICATE OF COMPLIANCE Prescriptive Residential Re-roof Project Name:

CERTIFICATE OF COMPLIANCE Prescriptive Residential Re-roof Project Name: STATE OF CALIFORNIA RESIDENTIAL ALTERATIONS - RE-ROOF CERTIFICATE OF COMPLIANCE Prescriptive Residential Re-roof Project Name: CALIFORNIA ENERGY COMMISSION CF-1R-ALT-01-E (Page 1 of 2) Date Prepared: A.

More information

AAMA/WDMA/CSA 101/I.S.2/A440-05 TEST REPORT. Rendered to: EAGLE WINDOW & DOOR COMPANY

AAMA/WDMA/CSA 101/I.S.2/A440-05 TEST REPORT. Rendered to: EAGLE WINDOW & DOOR COMPANY Architectural Testing AAMA/WDMA/CSA 101/I.S.2/A440-05 TEST REPORT Rendered to: EAGLE WINDOW & DOOR COMPANY SERIES/MODEL: Series 01 Axiom Clad One-Piece Casement Fixed 6060 PRODUCT TYPE: Aluminum Clad Fixed

More information

TEST REPORT. Report No.: A9814.01 109 44. Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

TEST REPORT. Report No.: A9814.01 109 44. Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept Architectural Testing TEST REPORT Report No.: A9814.01 109 44 Rendered to: BAMCO INC. Middlesex, New Jersey PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept AAMA 508 07, Voluntary Test Method

More information

REPORT HOLDER: HILTI, INC SOUTH 122 ND EAST AVENUE TULSA, OKLAHOMA EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-DRIVEN FASTENERS

REPORT HOLDER: HILTI, INC SOUTH 122 ND EAST AVENUE TULSA, OKLAHOMA EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-DRIVEN FASTENERS 0 ICC-ES Report ICC-ES (800) 42-6587 (562) 699-054 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-66 Valid: 0/5 to 0/7 DIVISION: 0 00 00 CONCRETE SECTION: 0 5 00 CONCRETE ACCESSORIES SECTION:

More information

LARGE WIND MISSILE IMPACT PERFORMANCE OF PUBLIC AND COMMERCIAL BUILDING ASSEMBLIES

LARGE WIND MISSILE IMPACT PERFORMANCE OF PUBLIC AND COMMERCIAL BUILDING ASSEMBLIES Florida A & M University - Florida State University College of Engineering Department of Civil and Environmental Engineering University of Florida, College of Engineering Department of Civil & Coastal

More information

FLORIDA PRODUCT APPROVAL

FLORIDA PRODUCT APPROVAL FLORIDA PRODUCT APPROVAL Frequently Asked Questions January 2005 The Florida Product Approval System was implemented on October 1, 2003. Many product manufacturers and building officials are asking questions

More information

http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wgevxqwtdqtkahqb3dx8wn...

http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wgevxqwtdqtkahqb3dx8wn... Florida Building Code Online http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wgevxqwtdqtkahqb3dx8wn... Page 1 of 2 8/3/2015 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats

More information

Klip Rib Guide Specifications MANUFACTURER - AEP SPAN 2141 Milwaukee Way, Tacoma, WA 98421, Beech Avenue, Fontana, CA 92337

Klip Rib Guide Specifications MANUFACTURER - AEP SPAN 2141 Milwaukee Way, Tacoma, WA 98421, Beech Avenue, Fontana, CA 92337 Klip Rib Guide Specifications MANUFACTURER - AEP SPAN 2141 Milwaukee Way, Tacoma, WA 98421, 800-733-4955 10905 Beech Avenue, Fontana, CA 92337 This Guide Specification is to be used to develop an office

More information

Sundance Supply, LLC. Greca Corrugated Polycarbonate Design & Install. To order Polycarbonate see >

Sundance Supply, LLC. Greca Corrugated Polycarbonate Design & Install. To order Polycarbonate see > Sundance Supply, LLC Greca Corrugated Polycarbonate Design & Install To order Polycarbonate see > http://www.sundancesupply.com Corrugated polycarbonate is sold in 1 ft. Increments. (1) (2) 30ʼ x 48ʼ Greenhouse

More information

Preformed Metal Roofing and Siding

Preformed Metal Roofing and Siding Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision

More information

DENVER MODEL 30 X 30 SPECIFICATIONS

DENVER MODEL 30 X 30 SPECIFICATIONS DENVER MODEL 30 X 30 SPECIFICATIONS Dimensions: Roof Dimensions 30-0 x 30-0 (4) Columns (Center to Center) 25-6½ x 25-6½ Minimum Clearance 8-0 Roof Height @ Peak Dependent on Col. Ht. Hip Roof 4:12 pitch

More information

INSULATED PANELS. SEE THE DIFFERENCE in appearance, value, performance and installation

INSULATED PANELS. SEE THE DIFFERENCE in appearance, value, performance and installation INSULATED PANELS SEE THE DIFFERENCE in appearance, value, performance and installation 1 Leading the industry in technology, design flexibility, quality, and value for more than half a century, American

More information

High Performance Building Systems. Building Science Solutions Extreme Thermal Performance Insect & Mold Resistant

High Performance Building Systems. Building Science Solutions Extreme Thermal Performance Insect & Mold Resistant High Performance Building Systems Building Science Solutions Extreme Thermal Performance Insect & Mold Resistant Cutting Edge Technology SIPS-Structurally Insulated Panels SIPs are high-performance building

More information

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY Architectural Testing PERFORMANCE TEST REPORT Rendered to: GLASSCRAFT DOOR COMPANY SERIES/MODEL: Mahogany Entry Door PRODUCT TYPE: 6' x 8' Double Outswing Hardwood TDL Door with Half Circle TDL Transom

More information

SECTION THERMOPLASTIC MEMBRANE ROOFING (Changed by Addendum 2)

SECTION THERMOPLASTIC MEMBRANE ROOFING (Changed by Addendum 2) SECTION 07 5419 THERMOPLASTIC MEMBRANE ROOFING (Changed by Addendum 2) PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Rigid roof insulation. 2. (Changed by Addendum 1) Mechanically attached single

More information

BXUV.P523 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263

BXUV.P523 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263 Page 1 of 5 Page Bottom BXUV.P523 Fire Resistance Ratings - ANSI/UL 263 Fire Resistance Ratings - ANSI/UL 263 See General Information for Fire Resistance Ratings - ANSI/UL 263 Design No. P523 March 21,

More information

A. Prefinished, prefabricated structural standing seam roof system with continuous interlocking field formed seams.

A. Prefinished, prefabricated structural standing seam roof system with continuous interlocking field formed seams. SECTION 07411 - PART ONE GENERAL 1.1 SECTION INCLUDES A. Prefinished, prefabricated structural standing seam roof system with continuous interlocking field formed seams. B. Coordinate with installation

More information

Continuous Insulation Using Polyiso Wall Sheathing

Continuous Insulation Using Polyiso Wall Sheathing PIMA Technical Bulletin #403 Continuous Insulation Using Polyiso Wall Sheathing What it is, what it does, and why you need it About Polyiso Insulation Polyiso is a rigid foam insulation used in over 70%

More information

Page 1 of 5

Page 1 of 5 SPECIFICATIONS METAL COMPOSITE MATERIAL WALL PANELS ESTOLGA 3000 DRY SEAL SYSTEM PART 1 GENERAL 1.01 SECTION INCLUDES A. Exterior cladding consisting of formed metal composite material (MCM) sheet, secondary

More information

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression

More information

The following are building standards, relevant to timber frame construction and are referenced in the TGDs:

The following are building standards, relevant to timber frame construction and are referenced in the TGDs: Appendix 7: Reference Standards The following are building standards, relevant to timber frame construction and are referenced in the TGDs: Loading: BS 6399: Loading for Buildings Part 1: 1984, Code of

More information

Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature

Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature Thermal Values Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature relative to changing exterior temperatures. By reducing interior temperature

More information

www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council *Revised April 2014

www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council *Revised April 2014 ICC-ES Evaluation Report ESR-1647* Issued July 2013 This report is subject to renewal August 1, 2015. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION:

More information

SECTION 07 21 16 - PRE-ENGINEERED BUILDING BLANKET INSULATION

SECTION 07 21 16 - PRE-ENGINEERED BUILDING BLANKET INSULATION PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER: 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-3771 Issued 11/2015 This report is subject to renewal 11/2016. DIVISION: 06 00 00 WOOD, PLASTICS

More information

CUSTOM ENGINEERED BUILDINGS, TURN-KEY INSTALLATION, SITE PREPERATION, INTERIOR IMPROVEMENTS, ELECTRICAL AND MECHANICAL SERVICES CONTRACT GS-07F-0050V

CUSTOM ENGINEERED BUILDINGS, TURN-KEY INSTALLATION, SITE PREPERATION, INTERIOR IMPROVEMENTS, ELECTRICAL AND MECHANICAL SERVICES CONTRACT GS-07F-0050V CUSTOM ENGINEERED BUILDINGS, TURN-KEY INSTALLATION, SITE PREPERATION, INTERIOR IMPROVEMENTS, ELECTRICAL AND MECHANICAL SERVICES CONTRACT GS-07F-0050V GENERAL SERVICES ADMINISTRATION AUTHORIZED FEDERAL

More information

STANDARD FOR NON-FIRE RATED ROLLING DOORS

STANDARD FOR NON-FIRE RATED ROLLING DOORS ANSI/DASMA 203-2004 AMERICAN NATIONAL STANDARD STANDARD FOR NON-FIRE RATED ROLLING DOORS Door & Access Systems Manufacturers Association, International Sponsor: 1300 Sumner Ave Cleveland, Ohio 44115-2851

More information

Steel Roof Deck. RD Standard for. American National standards institute/ steel deck institute. copyright 2010 steel deck institute

Steel Roof Deck. RD Standard for. American National standards institute/ steel deck institute. copyright 2010 steel deck institute RD - 2010 Standard for Steel Roof Deck copyright 2010 steel deck institute 1. General 1.1 Scope: A. This Standard for Steel Roof Deck, hereaf ter referred to as the Standard, shall govern the materials,

More information

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY PERFORMANCE TEST REPORT Rendered to: GLASSCRAFT DOOR COMPANY SERIES/MODEL: Buffalo Forge Steel Doors / Round Top Single PRODUCT TYPE: In-swing Round Top Single Door RH-4 Title Uniform Load Deflection Test

More information

Design No. D708 June 14, Restrained Assembly Rating 3 Hr. Unrestrained Assembly Ratings 1-1/2 and 3 Hr.

Design No. D708 June 14, Restrained Assembly Rating 3 Hr. Unrestrained Assembly Ratings 1-1/2 and 3 Hr. Design No. D708 June 14, 2002 Restrained Assembly Rating 3 Hr. Unrestrained Assembly Ratings 1-1/2 and 3 Hr. Unrestrained Beam Ratings 1-1/2 and 3 Hr. Beam W10X17, min size. 1. Normal Weight or Lightweight

More information

CLOSED-CELL SPRAY FOAM Resisting Wind Uplift in Residential Buildings

CLOSED-CELL SPRAY FOAM Resisting Wind Uplift in Residential Buildings CLOSED-CELL SPRAY FOAM Resisting Wind Uplift in Residential Buildings RICHARD S. DUNCAN, Ph.D., P.E. JINHUANG WU, Ph.D. NOTICE: All statements, information and data given herein are believed to be accurate

More information

TECHNICAL WHITE PAPER

TECHNICAL WHITE PAPER TECHNICAL WHITE PAPER Insulated Metal Panels and NFPA 285 Introduction An Insulated Metal Panel (IMP) is a panel assembly comprised of a rigid foam plastic insulation core sandwiched between two sheets

More information

SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system

More information

Residential Deck Safety, Construction, and Repair

Residential Deck Safety, Construction, and Repair Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the

More information

SMARTBOARD Roof Board For Roof Assemblies. Designed to protect, strengthen and sustain roof assemblies

SMARTBOARD Roof Board For Roof Assemblies. Designed to protect, strengthen and sustain roof assemblies SMARTBOARD For Roof Assemblies Designed to protect, strengthen and sustain roof assemblies The ADVANTAGE was developed to meet the demands of challenging commercial roof assemblies; moisture/mold (food

More information

3. Where the existing roof has two or more applications of any type of roof covering.

3. Where the existing roof has two or more applications of any type of roof covering. City of Huntington Beach Department of Planning & Building REROOFING REQUIREMENTS 2000 Main Street, Huntington Beach, CA 92648 Office: (714) 536-5241 Fax: (714) 374-1647 This bulletin provides information

More information

Prescriptive Residential Wood Deck Construction Guide

Prescriptive Residential Wood Deck Construction Guide Bellevue Bothell Burien Issaquah Kenmore Kirkland Mercer Island 2009 Codes Prescriptive Residential Wood Deck Construction Guide Based on 2009 International Residential Code This tip sheet provides building

More information

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood Section 07411 Metal Roof Panels Part 1 General 1.1 Summary A. This section includes the following: a. Factory-formed

More information

TECHNICAL BULLETIN #19

TECHNICAL BULLETIN #19 Applying James Hardie Siding over Continuous Insulation and Non-Nailable Substrates SEPTEMBER 2014 TECHNICAL BULLETIN #19 The guidance and instructions provided in this technical bulletin are valid for

More information

The Rockcote INTEGRA Cavity Plus Cladding System

The Rockcote INTEGRA Cavity Plus Cladding System The Rockcote INTEGRA Cavity Plus Cladding System Contents 1 General Information 1 Specific Performance with the Building Code 2 Description of Product 2 Trade Literature 2 Scope & Limitations 2 Detailed

More information

Steel Building Systems

Steel Building Systems Steel Building Systems Steelway Product Specifications 1.0 Table of Contents 2.0 General 2 2.1 References 2 2.2 System Description 2 2.3 Design Criteria 2 2.4 Source Quality Control 3 2.5 Drawings 3 2.6

More information

BIGBEE STEEL BUILDINGS, INC.

BIGBEE STEEL BUILDINGS, INC. SINCE 962 Bigbee Steel Buildings has been a full service provider of steel building systems since 962. In the early years, we were known as a relatively small fabricator that offered exceptional quality

More information

n Three 4 x 4 butt hinges per door - prevents wracking and assures smooth positive operation n Heavy duty 16 gauge steel frame

n Three 4 x 4 butt hinges per door - prevents wracking and assures smooth positive operation n Heavy duty 16 gauge steel frame Weather Fin and bulb help keep bad weather outside and good air inside Windows: n Many light kits are available 1-LU 4 X 48 1-LE 16 X 16 1-LA 20 X 24 1-LI 20 X 24 1-B 22 X 36 1-LW 16 X 16 W/GRID 9-LB 22

More information

SECTION 07 61 13 STANDING SEAM METAL ROOFING

SECTION 07 61 13 STANDING SEAM METAL ROOFING SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced

More information

Wind Mitigation Inspection

Wind Mitigation Inspection tpatrick@ispects.me Tampa Bay Area: SW & Central Florida: (813) 368-6407 (239) 896-3986 Wind Mitigation Inspection VonHaase, Dale 4585 Bowen Bayou Road Sanibel, FL 33957 5/6/2013 Note to Policyholder:

More information

Pryda Timber Connectors

Pryda Timber Connectors Pryda Timber Connectors A complete guide to the design, specification and installation of Pryda Post Anchors March 2012 ESSENTIAL NOTES PRYDA PRODUCT GUIDES INTRODUCTION The information in this Product

More information

Section PRE-ENGINEERED METAL BUILDING SYSTEMS

Section PRE-ENGINEERED METAL BUILDING SYSTEMS SPECIFICATIONS Section 13120 PRE-ENGINEERED METAL BUILDING SYSTEMS PART 1 GENERAL 1.1 SECTION INCLUDES A. Metal Building System: 1. Structural steel framing system. 2. Metal roof system. 3. Metal wall

More information

October 25, 2011 PARTIES INTERESTED IN EVALUATION REPORTS ON ALTERNATIVE ASPHALT ROOFING SHINGLES

October 25, 2011 PARTIES INTERESTED IN EVALUATION REPORTS ON ALTERNATIVE ASPHALT ROOFING SHINGLES October 25, 2011 TO: PARTIES INTERESTED IN EVALUATION REPORTS ON ALTERNATIVE ASPHALT ROOFING SHINGLES SUBJECT: New Acceptance Criteria for Alternative Asphalt Roofing Shingles, Subject AC438-1011-R1 (JV/CA)

More information

SECTION 07410 METAL ROOF & WALL PANELS

SECTION 07410 METAL ROOF & WALL PANELS This document specifies Metal Roofing Systems prefinished factory formed metal roofing marketed as MRS System 2500 steel and aluminum roofing systems and includes MRS flashing and Trim. MRS finish is a

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS LokSeam LokSeam 12" One of the most versatile architectural metal panels available today, LokSeam by ABC, is a snap-together, concealed fastener, standing seam roof system with a 13/4" tall vertical rib,

More information

Solar Water Heating and Solar Electric Generators Installed on One or Two Family Dwellings

Solar Water Heating and Solar Electric Generators Installed on One or Two Family Dwellings Solar Water Heating and Solar Electric Generators Installed on Category: Residential Construction Revised: [Paul L. Scarlett], Director Responsible Bureau Section: Development Services Center 1900 SW Fourth

More information