1 SECTION 0990 PAINTING PART GENERAL 1.01 SCOPE OF WORK: A. WORK INCLUDED: The Contractor shall furnish all necessary labor, materials, equipment and services to complete all field painting work indicated on the drawings and/or specified herein, including but not necessarily limited to the following: 1. Painting of exposed exterior ferrous metals and miscellaneous metals. 2. Painting of patch work and defaced areas resulting from demolition. 3. Painting of interior exposed ferrous miscellaneous metals including exposed metals embedded in concrete. 4. Painting of interior ferrous metals. 5. Painting of hollow metal doors and frames. 6. Painting of exposed piping for natural gas system. 7. All construction not factory finished shall be painted or finished as specified unless specifically noted otherwise. B. WORK NOT INCLUDED: The following items shall not be field painted: 1. Items made from brass, bronze, copper or stainless steel. 2. Manufactured items furnished with factory applied finishes, etc. 3. Electrical panels, switchgear, substations, transformers and other electrical equipment. 4. Compressors, air handling units and other mechanical equipment. 5. HVAC louvers and dampers. 6. Aluminum surfaces except where specifically noted otherwise. 7. Glass. 8. Rubber and fabric surfaces. 9. Interior finishes other than painted surfaces. C. RELATED WORK SPECIFIED ELSEWHERE: Refer to other Sections of these specifications for specific information concerning materials and construction requirements of work to be painted under this Section

2 1.02 QUALIFICATIONS: A. QUALIFICATIONS OF WORKMEN: All personnel engaged in the application of painting materials shall be thoroughly trained and experienced in the proper application of each material in accordance with the material manufacturer's written instructions and recommendations. B. QUALIFICATIONS OF SUBCONTRACTOR: The painting subcontractor shall have a record of successful completion of painting work for projects of similar scope and nature for a period of at least three years. The subcontractor shall be approved by the material manufacturer for application of his materials SUBMITTALS: A. COLOR CHARTS prepared by the paint manufacturer shall be submitted to the Engineer in accordance with Section 0130 for selection of colors. Colors will be selected by the Engineer from the manufacturer s standard selections. Selected colors will be returned to the Contractor in the form of an approved color schedule. The Engineer, however, reserves the right to vary colors of any surface to obtain the desired effect without increasing costs. No more than 10 different colors will be used for the project. B. Manufacturer's installation instructions shall be submitted to the Engineer in accordance with Section Maintain one set of these instructions at the jobsite for reference by the Engineer PRODUCT HANDLING: A. PROTECTION: 1. All necessary means shall be used to protect materials specified under this Section from damage before, during and after installation. 2. The work of other trades shall be adequately protected from damage resulting from work specified under this Section. 3. Protect factory finished work and work not requiring field painting from overspray, accidental spills, dripping, etc. 4. Protect all painted surfaces from the accumulation of dust during painting operations and thereafter until time of final inspection. 5. Protect Underwriter's labels on doors and other construction from paint coverage during painting operations. B. STORAGE AND HANDLING OF MATERIALS: 1. All materials shall be stored in field storage warehouses or the equivalent. Provide temporary space for the exclusive use of paint storage and paint mixing. No space will be allowed in the building for these purposes

3 2. Observe all regulations applicable to storage and mixing of paint and post all necessary safety signs, etc., as required by local and state codes and in conformity with good safety practices. Damage to any building or its contents caused by failing to exercise proper precautions to prevent such loss shall be made good by the painting contractor in a manner directed by the Engineer. 3. All paint, enamel, oil, turpentine and any other combustible or inflammable materials shall be stored in receptacles having tight covers each night or after each work period. All such receptacles shall be kept tightly closed. 4. All oily or paint-saturated cloths, rags or waste shall be removed from the buildings after each day's work or other work period. No flammable or combustible material of any kind shall be left unenclosed while inside buildings. C. REPLACEMENTS: 1. In the event of damage to materials or work in place, all necessary repairs and replacements shall be immediately made to the satisfaction of the Engineer at the sole expense of the painting contractor. 2. Work having factory finishes that are marred by the painting operation shall be replaced or field painted at the discretion of the Engineer at the sole expense of the painting contractor. D. PACKAGING AND MARKING: All materials shall be delivered to the jobsite in the manufacturer's standard unopened containers bearing the manufacturer's standard identifications and markings ENVIRONMENTAL CONDITIONS: A. TEMPERATURE: During application and drying of paint, a minimum temperature of 65 degrees F shall be maintained and held constant as possible. Surfaces whose temperature exceeds 120 degrees F shall not be painted. B. HUMIDITY: No painting shall be undertaken in damp, rainy weather or where relative humidity in area or spaces to be painted is greater than 65 percent. C. WIND: Paint shall not be applied when winds may cause dust or dirt to be embedded in the coating, nor when winds may interfere with proper spraying operation. D. VENTILATION: Provide adequate ventilation in all building areas where painting work is being performed. E. SAFETY: All painting shall be done under conditions and in a manner dictated by safe practices, using materials, tools and rigging of safe character. Comply with recognized safety rules and practices necessary to permit safe working

4 conditions for the workmen as well as to prevent hazards to others who may be in the vicinity of the work. Paint on or in the vicinity of energized electrical or rotating equipment, apparatus or lines shall not be done without the approval of the Engineer, and then only in accordance with all laws, rules, ordinances or regulations which apply. Precautions recommended by paint manufacturers in mixing and application shall be followed explicitly. F. JOB CONDITIONS: All building spaces shall be swept broom clean prior to commencement of painting work in the area. Painting of interior surfaces will not be permitted in an open unprotected environment COORDINATION: A. Cooperate with all affected trades in the preparation of surfaces and application of paint on work furnished under other sections of these specifications. B. Examine and study all drawings, specifications, schedules, manufacturer's data and other pertinent information relating to all work receiving field paint as required to produce and insure a proper painted finish. C. Materials shall be delivered in ample quantities sufficiently in advance of the need, to avoid any delays or interruptions in the work due to lack of proper materials. D. Surfaces left unfinished purposely to meet the requirements of other trades shall be painted or finished as part of work under this Section after all such work requiring unfinished surfaces is complete ACCEPTANCE AND TOLERANCES: A. Final acceptance of painting and finishing shall be based upon an inspection by the Engineer. Work failing to meet the requirements of these specifications will not be accepted. B. If the finished work, using the number of coats specified, does not yield a uniform color and texture acceptable to the Engineer, apply such additional coats as required to meet approval without additional cost to the Owner. PART PRODUCTS 2.01 MATERIALS: A. PAINTING MATERIALS: All painting materials shall be as manufactured by ICI Paint Stores, headquartered at 925 Euclid Avenue, Cleveland, OH (consisting of DEVOE, GLIDDEN, DEVOE COATINGS, AMERITONE,

5 DECRATREND, FULLER O BRIEN and SINCLAIR company-owned stores) or approved equal. 1. Generally, manufacturer shall mix all paints. Materials shall be thoroughly stirred. No materials shall be reduced or changed in any way except as specified by manufacturer. 2. Primers, sealers and undercoaters for paint work shall be of the same manufacture as the brand of paint specified. 3. Paint shall be well ground and mixed, and shall not settle or cake in the containers. Paint shall be readily broken up with a paddle to a smooth uniform paint of good brushing consistency, and shall dry hard to a smooth finish without streaking, running or sagging. 4. All colors and shades of paint shall conform to the approved color schedule, the manufacturer's color chart as submitted for color selection, and sample panels as approved by the Engineer. Any tinting or matching of colors shall only be done with the approval and concurrence of the Engineer. 5. Painting materials shall be furnished in accordance with the painting schedule at the end of this Section. ICI product identification names and numbers have been used in preparing the painting schedule. PART EXECUTION 3.01 EXAMINATION AND PREPARATION OF SURFACES: A. EXAMINATION OF SURFACES: The painting contractor shall examine all surfaces that are to be painted, work conditions under which painting work must be accomplished, and any other conditions affecting the proper painting of all work. Report to the Engineer any and all conditions which adversely affect the work and thereby preclude a high quality job of painting and finishing. No "waiver of responsibility" for incomplete, inadequate or defective underlying or adjoining work will be considered by the Engineer unless notice of such unsatisfactory conditions has been filed and agreed to, in writing, by the Engineer before the painting work begins. Application of first field coat on any surface shall be construed as evidence that the surfaces are acceptable to the painting contractor as being in proper condition for application of paint under this Section. Where there is any question of dryness of surfaces, test surfaces in the presence of the Engineer. B. GENERAL PREPARATION OF ALL SURFACES: All surfaces shall be cleaned and prepared in strict accordance with the paint system manufacturer's instructions and recommendations. Immediately prior to paint application, all surfaces shall be made perfectly clean, dry, smooth and free of all dust, dirt, grease, oil, mildew, splinters, rust, scale and other extraneous matter which might adversely affect the finished work. All surface defects shall be corrected prior to painting. Oil and grease shall be removed with solvent intended for such purpose. Loose scale and rust shall be removed by

6 scraping, wire brushing or sand blasting. Rough areas and spots in smooth surfaces shall be sanded and rubbed smooth to match adjacent areas. Enamel undercoats shall be sanded smooth after the undercoats are dry and prior to recoating. All holes, cracks and blemishes shall be filled with appropriate putty, filler, caulking or spackling compound after application of prime coat has become hard and dry and before second coat is applied. All abraded areas in shop applied prime coats shall be touched-up with matching primer. Apply appropriate barrier coating over any shop primed surfaces that are incompatible with the field paint system specified. Remove electrical switch plates, receptacle plates and exterior door hardware prior to painting. Replace such items after completion of painting in each area with skilled mechanics. C. ADDITIONAL PREPARATION OF FERROUS METAL SURFACES: Clean unprimed ferrous metal surfaces including bolts, nuts, washers and welds to bare metal with wire brush and appropriate solvent. Apply field prime coat to such items. Remove defective shop prime coats and field prime where necessary to insure a high quality finish. Galvanized metal shall be thoroughly cleaned of all foreign matter and etched to a dull paint-receptive surface, unless otherwise specified INSTALLATION AND WORKMANSHIP: A. PAINT APPLICATION: 1. Manufacturer's Instructions: All paint materials shall be applied in strict accordance with the manufacturer's written instructions and recommendations except where more stringent requirements are set forth by these specifications. 2. Mixing: Mixing of paint materials shall be in accordance with the paint manufacturer's written instructions. Provide new mixing containers of suitable size for mixing paint. No mixing will be permitted outside of these containers. With the exception of ready-mixed materials, all mixing shall be done at the jobsite. All paints shall be thoroughly mixed prior to application. Thinning, if required, shall be done with the type of reducer recommended by the paint manufacturer in accordance with the paint manufacturer's written instructions. 3. Painting of Shop Coat: Field prime coats may be omitted on materials shipped to jobsite already adequately primed except where an additional prime coat is specified in the painting schedule. Shop prime coats that have been damaged, marred or abraded shall be touched-up or reprimed. Any surfaces where shop prime coats are not compatible with special coatings shall receive a proper barrier coat of paint applied before applying subsequent coatings

7 4. Paint Film Thickness: Paint covering shall not exceed the spread per gallon recommended by the paint manufacturer. Paint shall be applied in such a manner as to yield the dry film thickness recommended by the manufacturer. Film thickness indicated in the painting schedule are expressed in mils of dry film thickness. B. SPECIAL APPLICATION INSTRUCTIONS: 1. Paint top, bottom and side edges of all metal doors. Paint metal doors prior to installation of hardware. Seal top, bottom and side edges of all wood doors. 2. All gas piping shall be painted ANSI Safety Yellow. C. SEQUENCING AND SCHEDULING: 1. Painting work shall not begin until after the Engineer's issue of approved color schedule and approval of field sample panels. 2. The painting contractor shall be responsible for the final finish on his work and should, therefore, sequence and schedule his work to be performed under conditions that will yield first quality work conforming in every respect to these specifications. 3. Painting work shall not be started until the building structure is properly dried in and ready for painting. 4. Painting work in an area shall not be started until all other work has been completed and all materials requiring field painted finishes are permanently in place. Any extra painting work resulting from the failure to comply with this requirement shall be performed by the painting contractor at no additional cost to the Owner. 5. Stop exterior work sufficiently early to permit paint film to set up before condensation, frost and moisture caused by night temperature drop occur. 6. Each coat of paint shall be allowed to thoroughly dry before application of next coat. Unless otherwise specified, exterior oil paints shall dry at least 48 hours between coats. Interior paints shall dry at least 24 hours between coats. 7. Paint hollow metal doors two coats prior to installation of door hardware. Paint top and bottom edges of doors prior to erection

8 D. WORKMANSHIP: 1. All workmanship shall be of the highest grade. All materials shall be applied to completely cover all surfaces evenly so as to dry uniformly in color and sheen, free from runs, sags, laps, skips, holidays, pinholes, wrinkles, shiners, streaks, and brush marks. Each coat shall be applied smooth, worked out evenly and allowed to dry before subsequent coat is applied. Paint shall not be floated on or applied in thick, heavy coats. The priming coat shall be thoroughly applied to fill all pores, crevices, etc. All brushes, spray nozzles and rollers shall be clean and in good condition. 2. Make edges of paint adjoining other materials or colors sharp and clean without overlapping FIELD QUALITY CONTROL: A. Before applying each coat of paint, the painting contractor shall thoroughly inspect the previous coat making certain that it is ready to receive the next specified coat. Previous coating shall be thoroughly cured. Allow specified drying time and check film with fingernail to be certain it is cured. Noncompatible and nonadherent materials shall be removed from previous coat. B. The Engineer shall be notified and given an opportunity to inspect each paint coat in major building areas prior to application of next coat. Failure to make such notification may result in additional coats at no additional expense to the Owner. C. Immediately prior to final inspection, the painting contractor shall thoroughly inspect the project for defective painting work. All defects in paint application and surfaces damaged during the course of construction shall be repaired and repainted prior to final inspection CLEANING: A. During the course of construction, the painting contractor shall periodically clean up all surplus materials, debris, and rubbish resulting from the painting operation and remove same from the jobsite. B. Upon completion of the work, the painting contractor shall remove all surplus materials, scaffolds, debris, etc. from the premises. All rooms and spaces shall be left broom clean. C. All misplaced painting and paint dust shall be removed from glass, light

9 fixtures, floors, mechanical equipment, electrical equipment and other building construction elements. Cleaning operations shall be carried out in such a manner that finished surfaces will not be marred or damaged. D. The building premises and all painted surfaces shall be left clean in a condition satisfactory to the Engineer. E. Factory finished surfaces that cannot be properly cleaned without damage, shall be electrostatically painted as directed by the Engineer. (See Attached Painting Schedule)

SECTION 807 PUMP STATION REHABILITATION

SECTION 807 PUMP STATION REHABILITATION SECTION 807 PUMP STATION REHABILITATION 807-1 DESCRIPTION: Rehabilitation of pump stations shall be defined as the cleaning, removal, repair and/or replacement of any and/or all components including but

More information

SECTION 15420 WATER STORAGE TANK PAINTING

SECTION 15420 WATER STORAGE TANK PAINTING SECTION 15420 WATER STORAGE TANK PAINTING PART 1 GENERAL.01 SCOPE A. Section Includes Surface preparation, shop priming, and field coating for interior wet, interior dry, and exterior surfaces of steel

More information

BRIDGE FIELD PAINTING, REPAINTING, 412 AND PAINT RESIDUE CONTAINMENT. A. Field Painting, Bridge Repainting and Residue Containment:

BRIDGE FIELD PAINTING, REPAINTING, 412 AND PAINT RESIDUE CONTAINMENT. A. Field Painting, Bridge Repainting and Residue Containment: 412.1 DESCRIPTION BRIDGE FIELD PAINTING, REPAINTING, 412 This specification contains the requirements for the removal, containment, and disposal of existing paint on steel surfaces, preparing the steel

More information

COATING & WRAPPING OF UNDERGROUND PIPING

COATING & WRAPPING OF UNDERGROUND PIPING CONSTRUCTION STANDARD SPECIFICATION DOCUMENT NO :SEC-PJ-000-SPC-PI-008 TOTAL PAGES : 8 Page 1 of 8 CONTENTS 1. SCOPE 2. DEFINITION 3. CODES AND STANDARDS 4. MATERIALS Page 2 of 8 1. SCOPE This specification

More information

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION 623.10 CONCRETE BONDING COMPOUND.

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION 623.10 CONCRETE BONDING COMPOUND. SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION 623.10 CONCRETE BONDING COMPOUND. 623.10.1 Description. This work shall consist of preparing the surface,

More information

GUIDE SPECIFICATION COMBINATION SURFACE SYSTEM FOR NEW HOT MIX ASPHALT TENNIS COURTS I. PART 1 - GENERAL

GUIDE SPECIFICATION COMBINATION SURFACE SYSTEM FOR NEW HOT MIX ASPHALT TENNIS COURTS I. PART 1 - GENERAL COMBINATION SURFACE SYSTEM FOR NEW HOT MIX ASPHALT TENNIS COURTS I. PART 1 - GENERAL 1.1 SUMMARY A. This section is a part of the entire set of Contract Documents and shall be coordinated with the applicable

More information

Tractor Painting Tips

Tractor Painting Tips Keeping your tractor or equipment well kept & free from rust & corrosion will extend the life of your investment & help retain its value for a longer period of time. It can be difficult, in many cases,

More information

T R A N S F E R A B L E F U L LY

T R A N S F E R A B L E F U L LY HSTOPS A WALL OF WATER 22 FT. HIG! F U L LY T R A N S F E R A B L E RESISTS10 PSI ! 1 F U L LY T R A N S F E R A B L E HSTOPS A WALL OF WATER 22 FT. HIG RESISTS10 PSI Guaranteed To Stop Water Even Under

More information

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1 KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1 PART 1 - GENERAL 1.01 RELATED DOCUMENTS: SECTION 16050 A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1

More information

A. Work on this project shall consist of, but is not limited to, the following:

A. Work on this project shall consist of, but is not limited to, the following: PART 1 - GENERAL CLEANING AND RESTORATION OF SECTION 05900-1 1.1 SUMMARY A. Work on this project shall consist of, but is not limited to, the following: 1. Clean and treat all exposed anodized architectural

More information

SECTION 01 50 00 CONSTRUCTION FACILITIES AND TEMPORARY CONTROLS

SECTION 01 50 00 CONSTRUCTION FACILITIES AND TEMPORARY CONTROLS SECTION 01 50 00 CONSTRUCTION FACILITIES AND TEMPORARY CONTROLS PART 1 - GENERAL 1.01 GENERAL REQUIREMENTS A. Regulations: Comply with industry standards and applicable laws and regulations of authorities

More information

METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES

METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES REFLECTICLEAN ACRYLIC/URETHANE Elastomeric Roofing Systems, Inc 6900 Bleck Dr. Rockford, MN 55373 800.403.7747 -or- 763.565.6900 fax: 763.565.6901 email:

More information

Mechanical Installation

Mechanical Installation Page -1-1. INTRODUCTION AND PURPOSE 1.1. This specification covers the installation, testing and precommissioning of mechanical equipment. Work is to be performed in conjunction with the manufacturer s

More information

A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents.

A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents. POLYURETHANE COATING ON STEEL PIPE PART 1 -- GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents. 1.2 REFERENCE SPECIFICATIONS,

More information

General Surface Preparation

General Surface Preparation General Surface Preparation Proper surface preparation will contribute significantly to the longevity of Ace Paint products. Follow these general guidelines for best results. CLEAN: Paint will not adhere

More information

Preformed Metal Roofing and Siding

Preformed Metal Roofing and Siding Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision

More information

SCENIC VIEW SV 10 SECTION 08 87 13 SOLAR CONTROL FILMS

SCENIC VIEW SV 10 SECTION 08 87 13 SOLAR CONTROL FILMS PART 1 GENERAL SCENIC VIEW SV 10 SECTION 08 87 13 SOLAR CONTROL FILMS 1.1 SUMMARY A. Optically clear dual reflective, neutral sputtered and aluminum metallized polyester film for solar control. 1.2 RELATED

More information

SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING

SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING PART ONE GENERAL DESCRIPTION This section includes pre-formed standing seam metal roofing and related flashings, closures, trim and accessories including,

More information

Active and Passive Sash Replacement

Active and Passive Sash Replacement for Andersen Gliding Windows Read all instructions carefully before attempting this procedure. If you have any questions about your ability to complete the procedure, call Andersen at 1-888-888-7020 for

More information

NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within

More information

INDUSTRIAL FLOORING INSTALLATION CHALLENGES. James C. Ziegler, ArmorSeal Product Manager Sherwin Williams Cincinnati, Ohio, USA

INDUSTRIAL FLOORING INSTALLATION CHALLENGES. James C. Ziegler, ArmorSeal Product Manager Sherwin Williams Cincinnati, Ohio, USA INDUSTRIAL FLOORING INSTALLATION CHALLENGES James C. Ziegler, ArmorSeal Product Manager Sherwin Williams Cincinnati, Ohio, USA Abstract: Specifier's and contractors not only need to properly evaluate the

More information

SECTION 33 12 19 FIRE HYDRANTS

SECTION 33 12 19 FIRE HYDRANTS SECTION 33 12 19 FIRE HYDRANTS PART 1: GENERAL 1.01 SCOPE A. Fire hydrants. B. Adjustment of fire hydrants and gate valves. 1.02 SUBMITTALS A. Conform to requirements of Section 01 33 00 - Submittals.

More information

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials SECTION 03 92 50 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings,

More information

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, 2012. All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, 2012. All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA Page 1 of 10, Addendum No. 3 Temporary Garage Structure City of Chelsea, MA November 5, 2012 CBI Job No.: 12055-A A D D E N D U M # 3 DATE: November 5, 2012 TO: FROM: PROJECT: All Bidders Jenne dos Santos,

More information

FIRESTOPPING & SMOKE SEALS

FIRESTOPPING & SMOKE SEALS SPECIFICATION SECTION 07 84 00 FIRESTOPPING & SMOKE SEALS 1 GENERAL 1.1 SECTION INCLUDES 1.1.1 Comply with Division 1, General Requirements and Documents referred to therein. 1.1.2 It is the intent of

More information

JOB READY ASSESSMENT BLUEPRINT PAINTING AND DECORATING. Test Code: 2060 Version: 01

JOB READY ASSESSMENT BLUEPRINT PAINTING AND DECORATING. Test Code: 2060 Version: 01 JOB READY ASSESSMENT BLUEPRINT PAINTING AND DECORATING Test Code: 2060 Version: 01 Specific Competencies and Skills Tested in this Assessment: Wood Finishes Identify thinning products Identify wood finish

More information

EXHIBIT A - SCOPE OF SERVICES CITY OF BREA GRAFFITI REMOVAL SERVICES. March 9, 2015

EXHIBIT A - SCOPE OF SERVICES CITY OF BREA GRAFFITI REMOVAL SERVICES. March 9, 2015 EXHIBIT A - SCOPE OF SERVICES CITY OF BREA GRAFFITI REMOVAL SERVICES March 9, 2015 Graffiti Removal Specifications GENERAL DESCRIPTION The services to be provided under this Proposal shall include the

More information

SC2000 CEMENT BONDING PROCEDURES

SC2000 CEMENT BONDING PROCEDURES Pg.1 SC2000 CEMENT BONDING PROCEDURES Widely recognized as the world s finest cold vulcanizing cement REMA SC2000 is the solution to your industrial bonding problems. By using REMA UTR20 hardener with

More information

UFGS-09 96 00 (July 2007) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS-09 96 00 (July 2007) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-09 96 00 (November 2014) ----------------------------- Preparing Activity: NASA Superseding UFGS-09 96 00 (July 2007) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS AN ERGONARMOR COMPANY TECHNICAL INFORMATION SPECIFICATION FOR INSTALLATION 07/11 SUPERSEDES 04/00 PAGE 1 OF 6 CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS 1. SCOPE 1.1 This specification

More information

SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word

More information

POLYURETHANE LINING AND COATING ON PIPE RAW WATER

POLYURETHANE LINING AND COATING ON PIPE RAW WATER POLYURETHANE LINING AND COATING ON PIPE RAW WATER PART 1 -- GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents. 1.2

More information

SECTION 560 COATING NEW STRUCTURAL STEEL

SECTION 560 COATING NEW STRUCTURAL STEEL 560 COATING NEW STRUCTURAL STEEL. (REV 10-1-132911121-131416-1213) (FA 1-162-1-13) (7-13) SECTION 560 COATING NEW STRUCTURAL STEEL 560-1 Description Coat new structural steel in accordance with the requirements

More information

WATERPROOFING FOR CONCRETE STRUCTURES

WATERPROOFING FOR CONCRETE STRUCTURES MANUAL OF CONTRACT DOCUMENTS FOR ROAD WORKS VOLUME 1 SPECIFICATION FOR ROAD WORKS SERIES 2000 WATERPROOFING FOR CONCRETE STRUCTURES Contents Clause Title Page 2001 General 2 2002 Protection of Bridge Deck

More information

2. Division 05 Structural Steel Framing for steel framework requirements

2. Division 05 Structural Steel Framing for steel framework requirements SECTION 131200 - CLIMBING WALLS PART 1 GENERAL 1.1 SUMMARY A. This section includes the following: 1. GFRC Rock Realistic Climbing Wall System B. Related Sections 1. Division 04 Unit Masonry 2. Division

More information

BENTLEY ELEMENTS COLLECTION LVT

BENTLEY ELEMENTS COLLECTION LVT This document refers to the following products: Product Size Installation direction Seams treatment Elements Tiles See specifications 90 None Elements Planks See specifications Stair Step None Note: This

More information

GigaCrete Specification PlasterMax

GigaCrete Specification PlasterMax GigaCrete Inc. 6775 Speedway Blvd. Suite M105 Las Vegas, NV 89115 Ph (702) 643-6363 Fax (702) 643 1453 www.gigacrete.com GigaCrete Specification PlasterMax PlasterMax : Fire Rated Plaster for Direct Application

More information

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles INSTALLATION RECOMMENDATIONS Outdoor Rubber Tiles Prior to Installation: The Outdoor Rubber Tiles and accessory transition pieces intended for this installation have been shipped to you via a freight carrier

More information

SECTION 03 35 43 - POLISHED CONCRETE FINISHING. InovaCrete Polished Concrete Floor Finish (GUIDE SPEC)

SECTION 03 35 43 - POLISHED CONCRETE FINISHING. InovaCrete Polished Concrete Floor Finish (GUIDE SPEC) SECTION 03 35 43 - POLISHED CONCRETE FINISHING InovaCrete Polished Concrete Floor Finish (GUIDE SPEC) PART 1 GENERAL 1.01 SUMMARY This Section includes information about: A. Polished concrete finish in

More information

SECTION 03 35 43 POLISHED CONCRETE FINISHING

SECTION 03 35 43 POLISHED CONCRETE FINISHING SECTION 03 35 43 POLISHED CONCRETE FINISHING PART 1 - GENERAL 1.01 SUMMARY A. Provide polished concrete finishing system where indicated on drawings, complete. This section includes the following: 1. Concrete

More information

Division 9. SignaFlor Pad and Pour Flooring System

Division 9. SignaFlor Pad and Pour Flooring System Division 9 SignaFlor Pad and Pour Flooring System SPECIFICATIONS Page 1. General... 2 1.1 Description 2 1.2 Quality Assurance 2 1.3 Submittals 2 1.4 Delivery and Storage 3 1.5 Warranty 3 1.6 Working Conditions

More information

Minor Cracks in Horizontal Surfaces

Minor Cracks in Horizontal Surfaces Cracks, chips and broken or flaking areas in concrete are not only unsightly, they can lead to further deterioration of the surface. The result is a costly replacement project as opposed to a simple repair.

More information

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec 03500 Master Spec. 03 49 00 Page 1

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec 03500 Master Spec. 03 49 00 Page 1 C. S. I. Spec 03500 Page 1 PART 1 - GENERAL 1.01 SUMMARY:.01 Provide special glassfiber reinforced cement (GRC) shapes in accordance with the requirements of the contract documents..02 The installing contractor

More information

Solvent Cementing Instructions For Plastic Pipe & Fittings

Solvent Cementing Instructions For Plastic Pipe & Fittings Solvent Cementing Instructions For Plastic Pipe & Fittings Description Solvent cementing is the process of fusing plastic pipe and fittings by the use of an adhesive containing a suitable active solvent

More information

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2

More information

Vinyl Composition Tile Installation System

Vinyl Composition Tile Installation System Vinyl Composition Tile Installation System Product Gauge Size Vinyl No-Wax (Dry Back) Urethane No-Wax (Dry Back) 0.045" (1.1 mm) 0.080" (2.0 mm) IMPERIAL TEXTURE 0.094" (2.4 mm) STONETEX ChromaSpin COMPANION

More information

SECTION 07 61 13 STANDING SEAM METAL ROOFING

SECTION 07 61 13 STANDING SEAM METAL ROOFING SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced

More information

SECTION 14 20 10 - FREIGHT & PARKING GARAGE ELEVATORS PART I - GENERAL

SECTION 14 20 10 - FREIGHT & PARKING GARAGE ELEVATORS PART I - GENERAL SECTION 14 20 10 - FREIGHT & PARKING GARAGE PART I - GENERAL 1.1 SECTION INCLUDES [NOTE to AE: The following lists requirements that are specific to freight elevators. These requirements are in addition

More information

RUST BULLET, LLC 300 Brinkby Avenue, Suite 200, Reno, NV 89509 775-829-5606 www.rustbullet.com

RUST BULLET, LLC 300 Brinkby Avenue, Suite 200, Reno, NV 89509 775-829-5606 www.rustbullet.com PROJECT: Specifications for Surface Preparation and Paint Application ~ Ceiling / Steel Pickling Facility The Product Data Sheet and Material Safety Data Sheet are an integral part of these instructions.

More information

BLACK JACK ALL WEATHER ROOF COATING

BLACK JACK ALL WEATHER ROOF COATING PAGE: 1 of 6 PRINT DATE: 16/09/2004 BLACK JACK ALL WEATHER ROOF COATING DESCRIPTION BLACK JACK ALL WEATHER ROOF COATING is a solvent based, full bodied black brushable compound with added fibres for reinforcement.

More information

Infrastructure Services Department. Design & Construction Buildings & Parks SPECIFICATIONS. Walter Baker Sports Centre. Pool Column Repairs

Infrastructure Services Department. Design & Construction Buildings & Parks SPECIFICATIONS. Walter Baker Sports Centre. Pool Column Repairs Infrastructure Services Department Design & Construction Buildings & Parks SPECIFICATIONS Walter Baker Sports Centre Pool Column Repairs 100 Malvern Drive Ottawa, Ontario Project No. December 2014 Walter

More information

K2 STONE NATURAL VENEER

K2 STONE NATURAL VENEER INTRODUCTION WHAT IS K2 NATURAL THINSTONE VENEER? Natural K2 Stone veneer is real stone, cut 1 inch thick, making it light enough to be installed as a veneer. Sometimes referred to as thin veneer, thin

More information

SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system

More information

LOWELL REGIONAL WASTEWATER UTILITY SPECIFICATIONS FOR THE LOWELL MA CONCRETE FLOODWALL REPAIRS

LOWELL REGIONAL WASTEWATER UTILITY SPECIFICATIONS FOR THE LOWELL MA CONCRETE FLOODWALL REPAIRS Concrete Repairs LOWELL REGIONAL WASTEWATER UTILITY SPECIFICATIONS FOR THE LOWELL MA CONCRETE FLOODWALL REPAIRS PART 1 - GENERAL 1.01 DESCRIPTION OF WORK A. The work will occur within the City of Lowell

More information

SECTION 1081 COATING OF STRUCTURAL STEEL

SECTION 1081 COATING OF STRUCTURAL STEEL SECTION 1081 COATING OF STRUCTURAL STEEL 1081.1 Scope. This specification covers coating new and existing bridges and structures made of structural steel and miscellaneous metals. 1081.2 Systems of Coatings.

More information

Spray Booth Guideline

Spray Booth Guideline Department of Development Service 135 North D Street, Perris CA. 92570 Phone: (951) 443-1029 Fax: (951) 943-3293 PURPOSE The intent of this guideline is to provide the information necessary to ensure that

More information

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel

More information

CLEAR-DIVISIONS CENTERFOLD

CLEAR-DIVISIONS CENTERFOLD CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in

More information

BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION

BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION 07560 BUR BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION PART 1: GENERAL 1.01 SCOPE: To extend the useful service life of the aged or new asphalt built-up roof system and to reduce cooling

More information

Acrylic Enamel Topcoat

Acrylic Enamel Topcoat Acrylic Enamel Topcoat ACRYL-GLO TECHNICAL DATA SHEET The ACRYL-GLO single-stage acrylic enamel paint system provides a durable finish that is easy to apply and suitable for both commercial and passenger

More information

SIGMACOVER 280. PRODUCT DATA SHEET December 10, 2014 (Revision of March 1, 2014) DESCRIPTION

SIGMACOVER 280. PRODUCT DATA SHEET December 10, 2014 (Revision of March 1, 2014) DESCRIPTION DESCRIPTION Universal epoxy anticorrosive primer, based upon pure epoxy technology PRINCIPAL CHARACTERISTICS Universal epoxy primer system suitable for Ballast Tanks, Decks, Topside, Superstructure, Hull

More information

Installation System. Existing Resilient Sheet Floors

Installation System. Existing Resilient Sheet Floors Vinyl Composition Tile Installation System Product Adhesive/Full Spread Adhesive/Tile-On Comment Imperial Texture MultiColor RAVE Stonetex Companion Square Feature Tile/Strips ARTEFFECTS SAFETY ZONE Vinyl

More information

Product Information/Specifications

Product Information/Specifications BARN & FENCE PAINT NO. 25 BARN RED Smooth or rough sawn exterior vertical wood surfaces such as plywood, fences, shingles, shakes, siding. laminates, masonry and stucco surfaces. AVAILABLE IN: Gallon Only

More information

07 21 19 Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

07 21 19 Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM 07 21 19 STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM 7819 Broadview Road Cleveland, OH 44131 800-522-4522 February, 2011 SPEC NOTE: This guide specification is intended for use when specifying

More information

A. Shop Drawing submittals shall include, but not be limited to, the following:

A. Shop Drawing submittals shall include, but not be limited to, the following: SECTION 26 05 53 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical

More information

STANDARD SPECIFICATIONS SECTION 02512 CLEANING AND LINING WATER MAINS

STANDARD SPECIFICATIONS SECTION 02512 CLEANING AND LINING WATER MAINS STANDARD SPECIFICATIONS SECTION 02512 CLEANING AND LINING WATER MAINS PART 1 GENERAL 1.1 DESCRIPTION A. Section includes requirements for cleaning and lining existing cast iron and ductile iron water mains

More information

City of San Diego, CWP Guidelines

City of San Diego, CWP Guidelines PART 1 -- GENERAL SECTION 08520-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing aluminum windows with frames, bracing, glazing attachments, screens,

More information

Additional Information. Paint Application

Additional Information. Paint Application Additional Information Paint Prepared by: International Paint Ltd. www.international-pc.com The information in this guideline is not intended to be exhaustive; any person using the product for any purpose

More information

Colorado State University. Durrell Center Roof Repair

Colorado State University. Durrell Center Roof Repair Colorado State University Durrell Center Roof Repair SPECIFICATION: POLYURETHANE FOAM ROOFING l.0 GENERAL REQUIREMENTS The successful application of a polyurethane foam roofing system is dependent upon

More information

GUIDELINE SPECIFICATIONS

GUIDELINE SPECIFICATIONS GUIDELINE SPECIFICATIONS GORDON SOFFIT-SHIELD - An Exterior Metal Soffit System DIVISION 05 5800 or DIVISION 07 7700 Note To Specifier: SOFFIT-SHIELD should be installed by tradesmen that are experienced

More information

Packaged Terminal Air Conditioner Wall Sleeve Installation

Packaged Terminal Air Conditioner Wall Sleeve Installation Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation

More information

A. This Section includes rubberized asphalt sheet membrane waterproofing systems.

A. This Section includes rubberized asphalt sheet membrane waterproofing systems. SECTION 07110 SHEET MEMBRANE WATERPROOFING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Application of Exterior Wood Finishes

Application of Exterior Wood Finishes Application of Exterior Wood Finishes The following information is excerpted from the publication, Exterior Wood in the South Selection, Applications, and Finishes by Daniel L. Cassens and William C. Feist;

More information

James M. Pleasants Company

James M. Pleasants Company James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:

More information

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1. 212 F (100 C) calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1. 212 F (100 C) calculated VOC-US/Hong Kong. US EPA method 24 (tested) Not approved 2063;2064 1,2 2063 ^(ValidationDate) 1 Product description This is a two component solvent free polyamine cured coating. It is a general purpose tank lining with good chemical resistance.

More information

SMOOTHMOVE INSTRUCTIONS FURNITURE VAN EPOXY FLOOR FINISH KIT VOC-FREE - NO SOLVENT GENERAL INFORMATION KEY 87269AB

SMOOTHMOVE INSTRUCTIONS FURNITURE VAN EPOXY FLOOR FINISH KIT VOC-FREE - NO SOLVENT GENERAL INFORMATION KEY 87269AB SMOOTHMOVE INSTRUCTIONS FURNITURE VAN EPOXY FLOOR FINISH KIT VOC-FREE - NO SOLVENT GENERAL INFORMATION KEY 87269AB YOU ARE NOW GETTING READY TO USE SOLVENT FREE AND 100% SOLIDS HIGH GLOSS SMOOTHMOVE FOR

More information

Core & Shell Construction. Rules and Regulations

Core & Shell Construction. Rules and Regulations Core & Shell Construction Rules and Regulations 1. Protection: During the construction Contractor shall endeavor to protect all areas of work from damage caused by workers, weather or equipment. 2. Permits

More information

NEOGARD. Preventive Maintenance Manual

NEOGARD. Preventive Maintenance Manual NEOGARD Preventive Maintenance Manual Fluid-Applied Roof Coating Systems December 2014 Notes NEOGARD luid-applied roof coating systems are designed to be long lasting, monolithic membranes which provide

More information

Scotch-Weld TM. Epoxy Adhesive 1838 B/A Green 1838 B/A Tan 1838-L B/A Translucent. Technical Data February, 2016. Product Description

Scotch-Weld TM. Epoxy Adhesive 1838 B/A Green 1838 B/A Tan 1838-L B/A Translucent. Technical Data February, 2016. Product Description 3 Scotch-Weld TM 1838 1838 1838-L Technical Data February, 2016 Description 3M TM Scotch-Weld TM s 1838 and are controlled flow products; Scotch-Weld 1838-L is flowable. These epoxy adhesives are two-part,

More information

Epoxy Floor Coating Problem Solving Guide

Epoxy Floor Coating Problem Solving Guide Table of Contents: Page: Troubleshooting Issue: 2. Color Differential 3. Fish Eye 4. Milky or Cloudy Coatings 5. Orange Peel 6. Peeling or Delamination 8. Delamination between Coats 9. Pinholes/Bubbling

More information

Wastewater Capital Projects Management Standard Construction Specification

Wastewater Capital Projects Management Standard Construction Specification CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 10.1 Precast Concrete Pipe 10.1.1 General This section covers material requirements,

More information

Section 02702 SEWER PIPE INSTALLATION AND TESTING

Section 02702 SEWER PIPE INSTALLATION AND TESTING PART 1 - GENERAL Section 02702 SEWER PIPE INSTALLATION AND TESTING 1-1. SCOPE. This section covers the installation and testing of all sewer pipe furnished under the following specification sections: Concrete

More information

Pipe and Equipment Insulations. Zeston. PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems

Pipe and Equipment Insulations. Zeston. PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems Pipe and Equipment Insulations Zeston PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems Zeston PVC Insulated Fitting Covers Installation Instructions for Hot,

More information

SECTION 15 AIR RELEASE VALVE ASSEMBLIES. 15-1 General

SECTION 15 AIR RELEASE VALVE ASSEMBLIES. 15-1 General SECTION 15 AIR RELEASE VALVE ASSEMBLIES 15-1.01 Scope 15-1 General This section describes the requirements for furnishing and installing Air Release Valve Assemblies of the size and type shown on the plans,

More information

RESTORE 10X Advanced Resurfacer FAQs Page 1 of 11

RESTORE 10X Advanced Resurfacer FAQs Page 1 of 11 Page 1 of 11 FEATURES & BENEFITS Q. Is the new Restore 10X Advanced Resurfacer replacing the first generation of Restore 10X? A. Yes, the new Restore 10X Advanced Resurfacer will replace the first generation

More information

Basement Window Installation Guide Hopper and Sliding

Basement Window Installation Guide Hopper and Sliding Basement Window Installation Guide Hopper and Sliding americancraftsmanwindows.com Project Requirements: Installation must comply with all applicable building codes. Existing window frame, wall and weatherresistant

More information

AUTO COLLISION REPAIR CERTIFICATE I COURSE DESCRIPTIONS. Total: 18 Credit Hours

AUTO COLLISION REPAIR CERTIFICATE I COURSE DESCRIPTIONS. Total: 18 Credit Hours CERTIFICATE I COURSE DESCRIPTIONS Total: 18 Credit Hours ACT 101 INTRODUCTION TO AUTOMOTIVE COLLISION TECHNOLOGY 4 Credit Hours Designed as an orientation to the automotive collision repair industry. Students

More information

RAPTOR TRUCK BED LINER - BLACK

RAPTOR TRUCK BED LINER - BLACK 4 x 750ml RAPTOR base coating x L RAPTOR hardener TECHNICAL DATA SHEET & U-POL s RAPTOR Truck Bed Liner is a durable K polyurethane coating that provides surfaces with a protective barrier. RAPTOR Tintable

More information

SECTION XXXXXX TECHNICAL SPECIFICATIONS FOR INSTALLATION OF PROTECTIVE COATINGS FOR MANHOLES, WETWELLS, AND OTHER SANITARY SEWER STRUCTURES

SECTION XXXXXX TECHNICAL SPECIFICATIONS FOR INSTALLATION OF PROTECTIVE COATINGS FOR MANHOLES, WETWELLS, AND OTHER SANITARY SEWER STRUCTURES 1.00 PART 1 GENERAL 1.01 SCOPE A. It is the intent of this contract to install a 100% solids epoxy monolithic coating to the walls, benches and inverts of all manholes and the specified surfaces of other

More information

SECTION 18370 SIGNAL WIRE AND CABLE

SECTION 18370 SIGNAL WIRE AND CABLE SECTION 18370 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for all cable and wire required for signal and signal power system wiring to wayside shelters, junction boxes, and factory

More information

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR 1910.252 WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR 1910.252 WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600 OSHA REGULATION: 9 CFR 90.5 WELDING, CUTTING, AND BRAZING ( HOT WORK ) A. POLICY. This procedure follows requirements set forth in 9 CFR 90.5.. This policy applies to all Hot Work operations being done

More information

PHOENIX 370-120 Product Data Sheet (Updated on 14-Jan-2012) www.phoenixasia.com.hk

PHOENIX 370-120 Product Data Sheet (Updated on 14-Jan-2012) www.phoenixasia.com.hk DESCRIPTION A water borne thin film intumescent coating for the fire protection of structural steelwork. PRODUCT FEATURES AND RECOMMENDED USES Provides up to 120 minutes fire resistance to structural steelwork.

More information

SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 16 BRIDGE DECK WATERPROOFING. 16.1 General...16-1. 16.2 Materials...16-1. 16.3 Equipment...

SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 16 BRIDGE DECK WATERPROOFING. 16.1 General...16-1. 16.2 Materials...16-1. 16.3 Equipment... SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 16 BRIDGE DECK WATERPROOFING TABLE OF CONTENTS 16.1 General...16-1 16.2 Materials...16-1 16.3 Equipment...16-1 16.4 Installation...16-2 16.4.1 Traffic Restrictions...16-2

More information

Sun Vinyl New Construction Windows Homeowner's Warranty

Sun Vinyl New Construction Windows Homeowner's Warranty Sun Windows Sun Vinyl New Construction Windows Homeowner's Warranty Vinyl Sun Windows, Inc. warrants for a period of 2 years that the quality of workmanship and materials of vinyl items shall be free from

More information

Metal Rescue Rust Remover Technical Data

Metal Rescue Rust Remover Technical Data Technical Data Product Description Metal Rescue TM is an innovative new technology that efficiently removes rust without harming surrounding materials. It is a water-based, non-toxic solution that is biodegradable

More information

RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES

RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES 1807 Elmwood Avenue, Suite 275 Buffalo, New York 14207 (800) 543-5155 RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES Fiberesin Wall System Provide materials and labor to complete courts

More information

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised Page 1 of 6 instructions VC 104+ Rigid Grade / VC 104+ Rigid Grade Imagine / (for the rest of this document referred to as VC 104) can be applied to new and used trucks and trailers with painted rigid

More information

[Note: This guide specification may be used for Polomyx All-Acrylic, Polomyx Waterbase and Zolatone Waterbase multicolor finishes.

[Note: This guide specification may be used for Polomyx All-Acrylic, Polomyx Waterbase and Zolatone Waterbase multicolor finishes. GUIDE SPECIFICATIONS SECTION 09945 POLOMYX ALL-ACRYLIC MULTICOLOR WALL FINISH ALL ACRYLIC WATERBASE ******** Polomyx All-Acrylic is a seamless, spray-applied paint system. It is visually complex, layered

More information

A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.

A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials. PART 1 GENERAL 1.1 SCOPE A. This item shall include the work necessary for the installation of storm sewer line construction. B. Reference Section 3800 Trenching and Backfill and the General Conditions,

More information