1 MA ANALOG FIRE ALARM SYSTEM The MA Analog Range is a clever addressable fire alarm control system capable of interfacing with advanced brain protocols of leading fire detection systems on the market. Its flexible design makes the MA-1000 one of the most powerful and cost effective analog panels available, with quick response time and easy integration to support a wide range of commercial and industrial applications. The minimalistic design of the MA offers advanced functionality to support complex cause and effect programming for industrial, hightech and military applications, as well as a wide range of public institutions such as hospitals, airports, universities, and others. CLEVER FIRE SOLUTIONS

2 MA-1000 Analog Addressable Panel MTech s MA-1000 range is an intelligent analog addressable fire alarm control panel with a two-loop configuration, with a future option of a four-loop operation. The MA product series abide to UL864 9th Edition standards, and are in accordance with current standards of the Russian and Israeli Standards Associations. The MA-1000 panel uses spur tolerant soft addressing to minimize installation time and remove the potential for errors associated with manual addressing. It assigns multiple addresses and saves addresses of removed devices for future use without affecting the remaining devices. Offered with the MA-1000 is an analog sub-control extension panel, the MA-1000SUB, with multiple interfacing connections to the main panel. All MTech fire detection system components operate as part of a fully integrated system with its panel, detectors, interfaces and other ancillaries in full compatibility with each other. Features: Two Class A Loops, with a future option of four loop operation Approved to UL864 9th Edition/ NFPA 2007 Compliant In accordance with Russian and Israeli fire standards Menu driven programming Soft addressing Up to 150 addressable devices per loop Short circuit isolators incorporated into each loop device Four programmable NAC s Three programmable relays One dedicated alarm relay One dedicated trouble relay RS232 and RS485 Easy to program Up to 16 panels on network 6.5 amp power supply System Functionality Four row graphic display that provides a simple and comprehensive menu-driven end-user interface: 64-character backlit LCD display (4 lines with 16 characters on each line) Holds up to 150 addressable devises per loop including a mixture of call points, detectors, interfaces, beacons and loop sounders. Designed to ensure future expansion: Even after the system has been programmed, the panel can allocate the next available address without altering any of the existing address number allocation. Uses soft addressing during commissioning: Addresses are locked until manually altered to enable simple system additions and deletions without affecting other addresses. Maintains full system integrity in the event of an external short-circuit fault: The panel s short circuit isolators on the devices nearest to each side of the short-circuit open to isolate a fault in the system and drives communication from both ends of the loop to sustain full communication with all system devices. Multiple stages and complex cause and effect programming: The panels are designed with a wide range of user controllable functions with three stages of cause-and-effect programming per output device to meet the needs of a wide range of small to large scale projects. Four programmable NAC s: The panel includes four programmable output NAC s with a maximum load of 1.2A. Programmable relays: The panel is designed with three programmable relays, one dedicated alarm relay, and one dedicated trouble relay. Power Supply: 6.5 amp / 2 /

3 Additional Expansion Modules Analog Sub Control Extension Panel MA-1000SUB The MA-1000SUB extension panel is an expansion module featuring four programmable NAC s, three programmable relays, two Class A loops, 150 addressable devices per loop, 6.5 amplifier, AC power supply and battery backup. Multiple MA-1000SUB extensions can be connected to the MA-1000 main panel with a network card, and the module is capable of independent operation in the event of network failure, transforming it into one of the most powerful analog panels on the market. Features: Standalone panel Internal LCD display Four programmable NAC s Three programmable relays Two Class A loops Up to150 addressable devices per loop 6.5 amplifier & backup battery Menu driven programming Up to 16 panels on network Power Booster MA-1100 The MA-1100 power booster is a 4.5 amp notification power expander compatible with MTech s fire alarm control panels. Up to eight units can be installed on the main panel. Complete with its own AC power, battery charging circuit and backup battery, the MA-1100 has four fully programmable NAC s, three completely programmable relays, one fire relay and one alarm trouble relays. It is programmed through the main panel. Features: Installation of up to eight units on the main panel 4.5 amp power supply Backup battery Four programmable NAC s Three programmable relays One fire relay One alarm trouble relay RS232 and RS485 Remote Annunciator MA 1050 The main control panel has a built-in annunciator with a four line, 64-character backlit LCD display with easy to understand system messages and a user-friendly membrane keypad. It additionally supports up to eight remote annunciators with matching control and display layout with two levels of user codes to limit operating system programming to authorized personnel only. The built-in annunciator also has five system status LEDs for Alarm, Supervisory, Trouble, Silence and AC power. The Reset and Silence buttons on the keyboard are noticeably larger than the rest. The annunciator enclosure can be surface or flush mounted. Features 64-character backlit LCD display (4 lines with 16 characters on each line) Membrane Keypad Accepts user codes or fire fighter s key (Optional) Larger Reset and Silence keypad buttons Eight remote installations per FACP RS-485 interface to panel On-board Piezo sounder audibly indicates Alarms, Troubles and Supervisories Five status LEDs for Alarm, Supervisory, Trouble, Silence and AC power conditions / 3 /

4 Typical Schematic: MA Analog Range Up to 16 panels on network MA-1000 Two Class A Loops Menu driven programming Soft addressing Up to 150 addressable devices per loop 4 programmable NAC s 3 programmable relays 1 dedicated alarm relay 1 dedicated trouble relay RS232 and RS485 Up to 16 panels on network MA-BSH MA-1050 Up to 8 panels per local panel NAC 1 NAC 2 MA-1000 NAC 3 MA-110 LOOP-2 NAC 4 RS-485 R5232 LOOP-1 MA-TA MA-3I3O MA-320 MA-320 MA-212OR MB-PBR CLEVER FI MB-220 MB-220 / 4 /

5 MA-1100 Installation of up to eight units on the main panel 4.5 amp power supply Backup battery Four programmable NAC s Three programmable relays One fire relay One alarm trouble relay RS232 and RS485 MA-1000SUB 2 Class A Loops Menu driven programming Soft addressing Up to 150 addressable devices per loop 4 programmable NAC s 3 programmable relays RS232 and RS485 Stand alone Up to 16 panels on network MB-FL Blower 1 RL MA-1050 Up to 8 panels per local panel Up to 150 devices per loop RL RL MA-1000SUB LOOP-2 RS-485 MB-LI LOOP-1 MA-340 MA-330 MA-320 MA-IN MA-CP MA-OR MA-Zone RE SOLUTIONS MB-240 MB-230 MB-220 MB-PBR / 5 /

6 Addressable Analog Detectors A variety of soft addressed low current analog detectors are available to operate with the MA addressable alarm system with advanced features, including simple installation, built-in short circuit isolators in each unit, easy to maintain, designed for 360 LED viewing, and more. MA-320 Optical photoelectric smoke detector MA-330 Multi-mode heat sensor MA-340 Photo-thermal smoke sensor MA-300 Standard European base Features Built-in short circuit isolators Aesthetically pleasing low profile design Led design with 360 view Removable detector chamber Drift compensation Benefits Quick and simple to install Single "multi-mode" heat sensor Common mounting base Positive "lock" indication Easy to maintain and service Addressable Sounders MA-S / MA-SH A loop-powered soft addressable wall sounder with built-in short circuit isolators. It offers excellent sound output levels while maintaining low current consumption. LED beacon available with MA-SH. Waterproof versions available. MA-BSH An intelligent addressable sounder beacon base for sensors or standalone device featuring tone selection and volume adjustment, single point connection for sensors, sounders and beacons, and can accommodate a powerful LED beacon (optional). MA-BS An intelligent addressable sounder base for sensors or standalone device featuring tone selection and volume adjustment, and single point connection for sensors and sounders, while maintaining low current consumption. / 6 /

7 Addressable Loop Devices Interfaces We offer an extensive variety of interfaces for the MA Analog Range. Our advanced soft addressed compact devices with short circuit isolators provide solutions to most design requirements, abide to UL864 9th Edition standards, and are in accordance with current standards of both the Russian and Israeli Standards Associations. MA-TA T-tap of addressable device: Connects to an SLC loop to make a Class B connection to system accessories. MA-2I20 Output module, with a one zone conventional detector, one zone manual call point, two sounder circuits and one relay. MA-OR An advanced and compact single channel output unit for a variety of interfaces. MA-IN A compact dry contact input monitoring module used to accept input signals from external equipment such as beam detectors, flow switches, valve monitor switches and others. MA-Zone A compact single zone monitor input, capable of interfacing with a zone of up to 20 conventional detectors on an analog fire panel. The module connects to addressable loop and acts as conventional slave under one address. MA-100PRO Programmer Robust and lightweight hand-held programmer that is easy to use with a user-friendly menu structure on a 2 40 character LCD display for the programming of all analog devices. MA-CP Call point surface, acts as a manual call point / 7 /

8 MTech Clever Fire Solutions At MTech, we introduce clever uninterrupted fire detection solutions committed to savings lives and property. With over two decades of experience in all aspects of fire detection and gas extinguishing systems, our design flexibility focuses on making high value products that abide by strict international standards with advanced capabilities and interfacing features that are cost effective to your bottom line. From the simplest installation to complex multi-building sites, we promise advanced solutions combined with professional consultation and training. MTech products are being integrated into projects in many parts of the world, including the Middle East, Asia, Eastern Europe and Russia. Our Core Values: Be the first to introduce clever and cost-effective uninterrupted fire detection solutions to improve life and property safety Invest in our experienced multi-lingual team who provide training and on-site consultation and technical support and forge long term relationships with our customers Committed to leading-edge product research and development To be fully compliant with the latest international standards CLEVER FIRE SOLUTIONS MTECH Clever Fire Solutions Kibbutz Hasolelim D.N Hamovil 17905, Israel Tel Fax

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit. Features. Description INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron s MMX-2017-12NDS Network Fire Alarm Control Unit offers modular components to meet a

More information

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual P/N 315-049403-1 Siemens Building Technologies Fire Safety Table Of Contents Introduction...1 The Access levels...1 User Level...1 Maintenance

More information

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description SFC-200 SERIES FIRE ALARM CONTROL PANELS SFC-200 Series Fire Alarm Control Panels Description Summit s SFC-200 Series fire alarm control panels consist of six and twelve zone models which are equipped

More information

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description INTELLIGENT FIRE ALARM CONTROL PANELS MR-2100/MR-2200 Intelligent Fire Alarm Control Panels Description MR-2100/MR-2200 Intelligent Fire Alarm Control Panel (shown with optional LED modules) Secutron's

More information

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems 1.0 Purpose A. The following guideline provides the minimum standards and requirements for fire alarm systems. 2.0

More information

CP-3500D WRA-3 Wireless Remote Annunciator Model AR-5 Repeater An optional RM-5 Plug-in Relay Module adds 5 Form C Relays to the AR-5.

CP-3500D WRA-3 Wireless Remote Annunciator Model AR-5 Repeater An optional RM-5 Plug-in Relay Module adds 5 Form C Relays to the AR-5. The CWSI System The CWSI wireless fire alarm product line offers system versatility like none other. Frequency Hopping Spread Spectrum Technology (FHSS), coupled with Bi-directional RF Communication, Repeater

More information

Potter Plus. Fire Alarm Control Panels

Potter Plus. Fire Alarm Control Panels Potter Plus Fire Alarm Control Panels Potter Fire: We stand apart. When it comes to fire protection companies, Potter stands apart. Apart from the competition and apart from the constraints of a large

More information

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS PROPERTY ADDRESS (BRT Address Required) TESTING CONTRACTOR (Name and Address) License No. ANNUAL

More information

Keypad D222. Installation Instructions. 1.0 Description. 1.3 Response Tones. 1.1 Display. 1.2 Keys

Keypad D222. Installation Instructions. 1.0 Description. 1.3 Response Tones. 1.1 Display. 1.2 Keys Keypad D222 Installation Instructions 1.0 Description The D222 Keypad (Figure 1) is a low-profile, surface-mount, three-wire unit with four hard-wired expansion points for use with Bosch Security Systems

More information

TECHNICAL DATA. Scan with smart phone to access Custom Zone Description Text. Viking Technical Data may be found on 24 Hour Clock

TECHNICAL DATA. Scan with smart phone to access Custom Zone Description Text. Viking Technical Data may be found on 24 Hour Clock Page 1 of 8 1. DESCRIPTION The Viking VFR400 is a microprocessor based multi-hazard releasing control panel for use on preaction, deluge, Surefire and Firecycle multicycle sprinkler systems, MX-1230 Fire

More information

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008 Premier Quatro Addressable Fire Alarm System Premier Quatro 4 Loop Analogue Addressable Fire Alarm Panel The Premier Quatro is the new 4 loop analogue Alarm Systems. It is available in 1, 2, 3 or 4 loop

More information

SECTION 13850 DETECTION AND ALARM

SECTION 13850 DETECTION AND ALARM SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring

More information

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S7010 7165-1477:111

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S7010 7165-1477:111 NETWORK FIRE ALARM CONTROL PANEL FX-2003-12NDS Description Mircom s FleX-Net Series is a powerful intelligent networkable fire alarm solution designed with many levels of flexibility to meet virtually

More information

Radi-Fire. Wireless systems from Channel Safety Systems

Radi-Fire. Wireless systems from Channel Safety Systems Radi-Fire Wireless systems from Channel Safety Systems Radi-Fire Wireless systems Radi-Fire provides a complete fire detection system without the need for a cabled connection between the field devices

More information

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10 TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified

More information

C E R T I F I C AT I O N LPCB B O A R D P R E V E N T L O S S. Cooper Fire Systems

C E R T I F I C AT I O N LPCB B O A R D P R E V E N T L O S S. Cooper Fire Systems P R E V E N T L O S S I O N C E R T I F I C AT LPCB B O A R D I O N Cooper Fire Systems ONE COOPER Every day, thousands of people all over the world use products made by Cooper Industries. As a premier

More information

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772

More information

Alliance System Ordering Guide

Alliance System Ordering Guide Alliance System Ordering Guide Multiple Technologies Versatile Hardware Powerful Software One family of parts and accessories Version 12-Nov-03 Alliance System Ordering Guide Table of Contents Controllers

More information

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION Phone System Owner Phone System Engineered by: of Record Drawings: of System Manuals: of Test Reports: System Installer 1. GENERAL INFORMATION Phone Delaware License No: Certificate Holder No. System Supplier

More information

Notifier by Honeywell: Panel Selection Guide

Notifier by Honeywell: Panel Selection Guide Notifier by Honeywell: Panel Selection Guide 1 Introduction This guide has been produced to help guide you through the advanced features of the Notifier range of addressable fire alarm control panels.

More information

Fire alarm system EBL128

Fire alarm system EBL128 Fire alarm system EBL128 An analog addressable fire alarm system for early detection without unwanted alarms 2011-09-28 Page 1 of 6 The demands on fire alarm systems are increasing. The system must have

More information

SECTION 16721 FIRE ALARM AND SMOKE DETECTION SYSTEMS

SECTION 16721 FIRE ALARM AND SMOKE DETECTION SYSTEMS SECTION 16721 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Fire Alarm Control Panels B. Manual Fire Alarm Stations C. Automatic Smoke D. Fire Alarm Notification Appliances E. Auxiliary Fire Alarm Equipment

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information

Repeaters and Mimics Data Sheet

Repeaters and Mimics Data Sheet Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.

More information

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals INFINITY The Intelligent 2 Wire Fire Detection System for Professionals Infinity ID 2 The intelligent 2 wire fire detection system for professionals In a nutshell Zeta Alarm Systems is proud to introduce

More information

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19 TECHNICAL SPECIFICATIONS Page 1 of 19 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC analogue addressable, electrically supervised, zone annunciated, fire detection and alarm system as

More information

INTELLIGENT FIRE ALARM CONTROL UNITS MMX-MNS TM

INTELLIGENT FIRE ALARM CONTROL UNITS MMX-MNS TM INTELLIGENT FIRE ALARM CONTROL UNITS MMX-MNS TM Intelligent Fire Alarm & Emergency Communications Network MMX-LOC MMX-BBX-FXMNS Description Secutron s MMX TM Series Mass Notification System (MNS) is designed

More information

Fire Detection Product Range

Fire Detection Product Range Fire Detection Product Range World Leading Fire Detection Products from the NITTAN group Issue 1.0 Business Overview The Nittan Group has been at the forefront of the fire protection industry since 1954

More information

FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL

FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL NOT YOUR STANDARD FIRE ALARM PANEL FLEXIBILITY, SPEED, INTELLIGENCE CyberCat the digital, peer-to-peer bi-directional, communication system that

More information

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL January, 2003 Environmental Health and Safety Florida Atlantic University 777 Glades Rd. Boca Raton, FL 33431 Phone: 561-297-3129 Fax:

More information

Fire detection equipment

Fire detection equipment PRODUCT CATALOG Fire detection equipment www.apollo-fire.com Apollo Fire Detectors is one of the world s largest manufacturers of fire detectors, modules and notification devices. Established in 1980,

More information

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications Gen4 Intruder Alarm Panels SIMPLY SECURE For Residential & Small Commercial Applications Overview and features 8 Zones Each one is separately identified on the keypad and provides ample security detection

More information

FIRE ALARM AND EMERGENCY VOICE EVACUATION SYSTEM

FIRE ALARM AND EMERGENCY VOICE EVACUATION SYSTEM FIRE ALARM AND EMERGENCY VOICE EVACUATION SYSTEM PART 1.0 - GENERAL 1.1 DESCRIPTION: A. This section of the specifications includes the furnishing, installation, and connection of a multiprocessor controlled,

More information

The supplier and installer of the system should be approved by the local civil defence authority.

The supplier and installer of the system should be approved by the local civil defence authority. ANALOGUE ADDRESSABLE FIRE ALARM SYSTEM 1. Scope of Work The contractor shall supply, install, test and commission a modern Analogue Addressable Fire Detection and Alarm System of an approved manufacturer

More information

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February 2013. FA-300 SERIES Fire Alarm Control Panel

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February 2013. FA-300 SERIES Fire Alarm Control Panel ABC DEF GHI JKL MNO PQR STU YZ WXY FA-300 Series LCD Fire Alarm Control Panel Advanced Life Safety Solutions System Normal 10:36AM WED 2003-10-01 SYSTEM RESET A.C. ON ALARM SUPV TRBL CPU FAIL SIGNAL SILENCE

More information

Product Information Fire alarm panel 8000 C

Product Information Fire alarm panel 8000 C Product Information Fire alarm panel 8000 C Fire alarm panel 8000 C, basic configuration In common with all modern Esser panels, the 8000 C fire alarm panel is based on high-performance ringbus technology.

More information

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12)

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) UL864 (Commercial Fire) Compliance General Requirements The VISTA-128FBPT/VISTA250FBPT

More information

The only One you need.

The only One you need. The only One you need. FIRE DETECTION Solution The TELEDATA products for the fire detection are compliant to the legislations in force EN 54/2 54/4 related to the fire detection (EN 54-2) and the power

More information

ALARM SYSTEMS PRODUCT CATALOG 2016

ALARM SYSTEMS PRODUCT CATALOG 2016 First Edition 2016 UniPOS is a high-tech independent manufacturer of a full range of fire alarm solutions for commercial and industrial applications. Our products are designed to save lives and protect

More information

Radio+ wireless system

Radio+ wireless system Radio+ wireless system A new secure wireless system Radio + provides a fire detection and alarm system using secure wireless connections between the field devices and the control panels. Introduction For

More information

Fire alarm system EBL512 G3

Fire alarm system EBL512 G3 Fire alarm system EBL512 G3 An analog addressable fire alarm system for early detection - without any unwanted alarms. Generation three G3. Internet: pesn.panasonic.se 2011-03-24 Page 1 of 6 The demands

More information

Wireless Detection System with unique detectors for smaller applications

Wireless Detection System with unique detectors for smaller applications Wireless Detection System with unique detectors for smaller applications RCP6 B wireless fire control panel microprocessor controlled 433 MHz 6 zones up to 100 radio addressable devices linkable 4 potential-free

More information

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM S7010 S7010 7165-1477:111

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM S7010 S7010 7165-1477:111 INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM BBX-FXMNSR Description BBX-5014R Mircom s FleX-Net TM Series Network Fire Alarm Control Panels offer modular components to meet a wide variety of applications.

More information

NJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen)

NJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen) Safely into a new day Advanced modular FIRE ALARM CONTROL PANEL with additional functionality NJP-400A NJP-401A I m on FIRE (Bruce Springsteen) EN 54-2, EN 54-4 Cert No. 1124a DESCRIPTION OP-400A, NJP-400A,

More information

Attachment 9. Trouble signals. Interfaced equipment. Primary (main) power supply

Attachment 9. Trouble signals. Interfaced equipment. Primary (main) power supply FIRE DETECTION, ALARM AND MASS NOTIFICATION SYSTEMS Inspection, testing, and maintenance of fire detection, alarm and Mass Notification systems shall be performed in accordance with the manufacturer's

More information

SECTION 16721 FIRE ALARM AND DETECTION SYSTEM

SECTION 16721 FIRE ALARM AND DETECTION SYSTEM 1. GENERAL 1.1. Related Documents: 1.2. Scope: 1.1.1. The general provisions of the Contract, including General and Supplementary Conditions and General Requirements apply to the work specified in this

More information

PRICE LIST 2015 INTERACTIVE ADDRESSABLE FIRE ALARM SYSTEM IFS7000 NTERACTIVE FIRE ALARM PANELS. Interactive Addressable Fire Alarm panel:

PRICE LIST 2015 INTERACTIVE ADDRESSABLE FIRE ALARM SYSTEM IFS7000 NTERACTIVE FIRE ALARM PANELS. Interactive Addressable Fire Alarm panel: PRICE LIST 2015 D. Obradovica 1, 81000 Podgorica, tel. 081/650-845, tel/fax 081/605-555 Budva 033/459-556 Ziro racun: 550-5722-86 Podgoricka banka PIB: 02424568, PDV: 30/31-04133-2 INTERACTIVE ADDRESSABLE

More information

Specifications Control Features. User Interface. Communicator. Programmable Outputs. Access Control. System Response

Specifications Control Features. User Interface. Communicator. Programmable Outputs. Access Control. System Response Control/Communicators Specifications Control Features Eight programmable areas, each with perimeter/interior partitioning. Regular, master, associate, or shared option by area Real-time clock and test

More information

FVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY

FVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY FVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fire-alarm control unit. 2. Addressable interface

More information

Fire Alarm System Plans Review Checklist Property location Date of Review

Fire Alarm System Plans Review Checklist Property location Date of Review Fire Alarm System Plans Review Checklist Property location Date of Review 1. Is application completed in entirety? 2. Are the plans review fee submitted with the application? 3. Does floor plan include

More information

SECTION 16700 FIRE ALARM SYSTEM

SECTION 16700 FIRE ALARM SYSTEM SECTION 16700 FIRE ALARM SYSTEM PART ONE: GENERAL 1.1 GENERAL REQUIREMENTS A. Definition of Work : This section of the specification includes the furnishing, installation, connection and testing of the

More information

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual EDA-Z5008 & Z5020 Radio Fire Alarm System User Manual Electro-Detectors Ltd. Electro House, Edinburgh Way Harlow, Essex, CM20 2EG UK Tel: 01279 635668. Fax 01279 450185 Email: eda@electrodetectors.co.uk

More information

A. Provide an extension to an existing DDC control system. The extension shall be Apogee product installed by Siemens Industry, Inc.

A. Provide an extension to an existing DDC control system. The extension shall be Apogee product installed by Siemens Industry, Inc. VAV Office Tenant Fitout Specification SECTION 23 09 00 AUTOMATIC TEMPERATURE CONTROLS PART 1 - GENERAL 1.1 AUTOMATIC TEMPERATURE CONTROLS A. Provide an extension to an existing DDC control system. The

More information

Operating the DS9400 Fire Alarm Control/Communicator

Operating the DS9400 Fire Alarm Control/Communicator TM 255 DETECTION SYSTEMS Power Alarm Troubl Silenced Supervised TM 255 DS9400 FIRE CONTROL/COMMUNICATOR Operating the DS9400 Fire Alarm Control/Communicator Outline I. Description II. Features III. Installation

More information

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems Fire Alarm System Plans Submittal Guidelines For New and Existing Systems SCOPE The Temecula Fire Prevention Bureau (TFPB) has established the following requirements for the submittal of all fire alarms,

More information

DTW Works Master Specification Version 2006

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section 13852 Multiplex Fire Alarm System Page 1 of 10 PART 1 GENERAL 1.1 RELATED WORK.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Procedures..3 Section 01810 Commissioning..4

More information

SECTION 13850 (28 31 00) FIRE DETECTION AND ALARM SYSTEM

SECTION 13850 (28 31 00) FIRE DETECTION AND ALARM SYSTEM SECTION 13850 (28 31 00) FIRE DETECTION AND ALARM SYSTEM ENGINEERING SPECIFICATION 25-POINT INTELLIGENT COMMUNICATING FIRE DETECTION SYSTEM PART 1 GENERAL 1.1. DESCRIPTION: A. This section of the specification

More information

INTRUSION DETECTION SYSTEM Section 281600

INTRUSION DETECTION SYSTEM Section 281600 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

More information

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST In order to provide a comprehensive plan review in a timely manner, and to insure the design and installation of fire alarm systems

More information

4100ES Fire Control Panels

4100ES Fire Control Panels Fire Fire ALARMS Priority 2 Priority 2 Supervisory Trouble Supv Trouble WARNINGS Silenced Silence AC Power Reset Page Up Previous Next Page Dn A B C D E F G H I ZONE J K L M N O P Q R FB IO IDNet 4 5 S

More information

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEM EURO ALARM Six zones with the following connection capabilities: One

More information

Expansion Modules & Accessories

Expansion Modules & Accessories HONEYWELL SECURITY & CUSTOM ELECTRONICS Expansion Modules & Accessories Honeywell s wide range of expansion modules and accessories enable you to configure a system to meet any installation challenge and

More information

Security with you in mind. As your needs change, NetworX security systems grow with you.

Security with you in mind. As your needs change, NetworX security systems grow with you. Security with you in mind. As your needs change, NetworX security systems grow with you. Advanced wired and wireless components to form a leading security system. Hard-wired Wireless Seamlessly integrating

More information

Fixed Gas Detection Equipment

Fixed Gas Detection Equipment CO 2 H 2 S CI 2 NH 3 O 3 CO Fixed Gas Detection Equipment O 2 CH 4 SO 2 CO 2 H 2 S Field mounted gas detection solutions for the protection of plant and personnel D e t e c t o r s Xgard Detectors for

More information

C E A S E F I R E S WIRELESS FIRE ALARMS

C E A S E F I R E S WIRELESS FIRE ALARMS C E A S E F I R E S WIRELESS FIRE ALARMS Wireless Fire Alarm System A dangerous enemy Smoke generated by fire has long been recognised as a threat to human life. It contains toxic chemicals and travels

More information

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS AGRI-ALERT ALARM SYSTEMS Peace of Mind Agri-Alert is a complete alarm system for monitoring temperature, power, feed and watering systems, burglary,

More information

Conventional Fire Detection and Extinguishant Control System Specification

Conventional Fire Detection and Extinguishant Control System Specification Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release

More information

COMPENSATION OF REACTIVE INPUT POWER POWER CONSUMPTION

COMPENSATION OF REACTIVE INPUT POWER POWER CONSUMPTION ENSURE CONTINUITY OF POWER SUPPLY DATA SHEET HIGH EFFICIENCY WARRANTY COMPENSATION OF REACTIVE INPUT POWER HYBRID WORK POWER CONSUMPTION UPS from series are on-line (VFI) class devices, intended to work

More information

SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS

SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS The equipment requirements of this section apply to the IUB Campus. The IUPUI Campus has a preferred vendor agreement for fire alarm systems. Contact Pat

More information

1.0 Introduction and Guided Tour 1. 3.0 Installation Instructions 3. 4.0 Commissioning 4

1.0 Introduction and Guided Tour 1. 3.0 Installation Instructions 3. 4.0 Commissioning 4 A1536 8 Way Alarm Board for Nexus 1-8 Loop Analogue Addressable Control Panels Application, Installation and Commissioning Manual Contents Page 1.0 Introduction and Guided Tour 1 2.0 Node Addressing Details

More information

SECTION 28 31 11 FIRE ALARM AND DETECTION SYSTEM

SECTION 28 31 11 FIRE ALARM AND DETECTION SYSTEM KNOXVILLE, TENNESSEE SECTION 28 31 11 PAGE 1 PART 1 - GENERAL 1.01 DESCRIPTION OF WORK SECTION 28 31 11 A. Extent of fire alarm and detection system work shall be as described in this specification, as

More information

FIRE ALARM SYSTEM CHECKLIST For Addressable Systems PRIOR TO INSPECTION

FIRE ALARM SYSTEM CHECKLIST For Addressable Systems PRIOR TO INSPECTION Building Name/Location: Installing Company: Observation By: Date: Time: 1 Building Occupants, Authorities and Alarm Monitoring Co Have Been Notified 2 FACP Manufacturer and Panel is Approved for NCSU Campus

More information

Professional fire alarm panel for small and medium-sized objects. Compact

Professional fire alarm panel for small and medium-sized objects. Compact Compact Professional fire alarm panel for small and medium-sized objects ESSER by Honeywell: The experts for safety in buildings With a comprehensive and future-oriented portfolio in the fields of fire

More information

PFC-6030 Fire Alarm Control Panel

PFC-6030 Fire Alarm Control Panel PFC-6030 Fire Alarm Control Panel Installation, Operation & Programming Manual Potter Electric Signal Company, LLC St. Louis, MO Customer Service: (866) 240-1870 Technical Support: (866) 956-1211 Fax:

More information

SECTION 16721 FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION

SECTION 16721 FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION SECTION 16721 FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION A. This section of the specifications includes the furnishing, installation, and connection of the microprocessor-controlled

More information

SFC-200 SERIES LCD FIRE ALARM PANEL

SFC-200 SERIES LCD FIRE ALARM PANEL SFC-200 SERIES LCD FIRE ALARM PANEL User Guide LT-954SUM SFC-200 Series LCD Version User Guide Contents Introduction... 1 About this Manual... 1 Technical Support... 1 Main Display... 1 The Buzzer and

More information

Global System Technology(UK) PLC The Intelligent Solution

Global System Technology(UK) PLC The Intelligent Solution Global System Technology(UK) PLC The Intelligent Solution MANUFACTURED IN ACCORDANCE WITH Intelligent Photoelectric Smoke Detector Aesthetically pleasing Low profile design 8 Bit intelligent processor

More information

Security with you in mind. As your needs change, NetworX security systems grow with you.

Security with you in mind. As your needs change, NetworX security systems grow with you. GE Security NetworX Security with you in mind. As your needs change, NetworX security systems grow with you. Hard-wired Wireless Carbon Monoxide Detector Glassbreak Detector Smoke Detector Motion Sensor

More information

Fire Control Panels. Panel Mounted LED/Switch and LED Modules, LED/Switch Controllers, and Panel Mounted Printer

Fire Control Panels. Panel Mounted LED/Switch and LED Modules, LED/Switch Controllers, and Panel Mounted Printer Fire Control Panels UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Panel Mounted LED/Switch and LED Modules, LED/Switch Controllers, and Panel Mounted Printer Features Panel mounted annunciation

More information

DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS

DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS 1. Description and Phone Number Dialing: The dialer shall be a solid state component capable of dialing up to 16 telephone numbers, each up to 60 digits

More information

Faraday Intelligent Fire Detection Systems

Faraday Intelligent Fire Detection Systems Faraday Intelligent Fire Detection Systems Faster detection means better protection for buildings and the people in them. Greater safety and value for new and retrofit applications The right fit Fire safety

More information

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system FIRE ALARM SYSTEM reliable fire detection and alarm signalling system Satel fire alarm devices allow to implement reliable and modern systems responsible for fire safety. A combination of 20-year experience

More information

BELMONT FIRE DEPARTMENT FIRE ALARM SYSTEM REQUIREMENTS BFD-OFM-10-011

BELMONT FIRE DEPARTMENT FIRE ALARM SYSTEM REQUIREMENTS BFD-OFM-10-011 Fire Alarm System plan(s) MUST be reviewed and approved by the Belmont Fire Department prior to the start of construction. The design and any changes must be fully compliant with NFPA 1, NFPA 101, NFPA

More information

Fire Control Panels. 4100 Series Remote InfoAlarm Command Center for the 4010ES Fire Alarm Control Panel

Fire Control Panels. 4100 Series Remote InfoAlarm Command Center for the 4010ES Fire Alarm Control Panel Fire Fire ALARMS Priority 2 Priority 2 Supervisory Supv WARNINGS Trou ble Trou ble Silenced Silence AC Po wer Reset Page Up Previous Next Page Dn A B C D E F G H I ZONE 1 SIG 2 J K L M N O P Q R FB 4 IO

More information

4-Wire Air Duct Smoke Detector. Protection Systems. A UTC Fire & Security Company. Models DH-60 FEATURES APPLICATION DESCRIPTION SAMPLING TUBES

4-Wire Air Duct Smoke Detector. Protection Systems. A UTC Fire & Security Company. Models DH-60 FEATURES APPLICATION DESCRIPTION SAMPLING TUBES 4-Wire Air Duct Smoke Detector Models DH-60 F-70.05 FEATURES Approvals/Listing UL 268A Listed File S1064 Factory Mutual Approved CSFM Listed #3240-1076:121 NYC MEA Listed #134-95-E City of Los Angeles

More information

Fire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction

Fire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction Emergency Operating Instructions Fire Alarm S Priority 2 Alarm Fire Alarm Priority 2 Ack Ack How Acknowledge / View Events Press ACK located under flashing indicar. Repeat operation until all events are

More information

3468-00 Lighting and Fire Alarm Training System Add-On

3468-00 Lighting and Fire Alarm Training System Add-On 3468-00 Lighting and Fire Alarm Training System Add-On LabVolt Series Datasheet Festo Didactic en 06/2016 Table of Contents General Description 2 List of Equipment 2 List of Manuals 2 Additional Equipment

More information

Software Release For DF6000/CF3000/FX6000. Site Installer Network Card

Software Release For DF6000/CF3000/FX6000. Site Installer Network Card Software Release For DF6000/CF3000/FX6000 Site Installer Network Card DF6000/CF3000/FX6000 Software Updates Latest Version: Display 3.03.50 Loop: 3.2.4 (14) Engineering Change Note : 1163 Site Installer

More information

Small Building Life Safety Solutions. GE Security. Affordable FireShield Conventional Fire Alarm Control Panels. imagination at work

Small Building Life Safety Solutions. GE Security. Affordable FireShield Conventional Fire Alarm Control Panels. imagination at work GE Security Small Building Life Safety Solutions Affordable FireShield Conventional Fire Alarm Control Panels imagination at work cost Location: Environment: Solution: Flower shop Finely decorated, gentle

More information

D287/D288/D292/D293A/D293E

D287/D288/D292/D293A/D293E D87/D88/D9/D9A/D9E EN Installation Guide Smoke Detector Bases D87/D88/D9/D9A/D9E Installation Guide.0 Overview.0 Overview The D87/D88/D9/D9A/D9E Smoke Detector Bases are designed for use with the D8 Ionization

More information

SECTION PROCESS INSTRUMENTATION AND CONTROL SYSTEM PROGRAMMABLE LOGIC CONTROLLERS

SECTION PROCESS INSTRUMENTATION AND CONTROL SYSTEM PROGRAMMABLE LOGIC CONTROLLERS SECTION 13311 - PROCESS INSTRUMENTATION AND CONTROL SYSTEM PROGRAMMABLE LOGIC CONTROLLERS PART 1 - GENERAL 1.01 WORK INCLUDED A. This Section covers work related to the Programmable Logic Controllers (PLC)

More information

Fire Pump Controllers Remote Alarm Panels

Fire Pump Controllers Remote Alarm Panels Fire Pump Controllers Remote Alarm Panels Remote Alarm Panels 1.8 Remote Alarm Panels FDAP-M Electric... DFDAP-M Diesel... Product Specifications... 2 6 9 Features 1-1 DFDAP-M / FDAP-M Remote Alarm Panel

More information

ASI Communications, Inc. ASI Annunciator

ASI Communications, Inc. ASI Annunciator ASI Communications, Inc. ASI Annunciator ANNR38 Installation and Operation Manual for the AES IntelliNet 7788F RF Subscriber Unit IMPORTANT! The AES 7788F Manual Document #40-7788 must be referenced in

More information

Building Solutions. One Honeywell Solution for All of Your Fire Systems Needs

Building Solutions. One Honeywell Solution for All of Your Fire Systems Needs Building Solutions One Honeywell Solution for All of Your Fire Systems Needs Intelligent and Accurate Detection Fire/CO The Advanced Multi-Criteria Fire/CO is a plug-in, addressable device that provides

More information

VEGA Analogue Addressable Control Panels

VEGA Analogue Addressable Control Panels Analogue Addressable Control Panels Representing the future of fire alarm control technology, Vega's modular concept enables the tailoring of system design for the smallest to the largest system. Designed

More information

nr 28 nr 68 nr 4 nr 1

nr 28 nr 68 nr 4 nr 1 SEEB INTERNATIONAL BILL OF QUANTITIES AIRPORT ELECTRICAL WORKS NEW TERMINAL PIER ITEM ITEM DESCRIPTION UNIT QUANTITY BILL PART SECTION No. VOLUME 3 4 UNIT RATE (R.O.) (in words) (in figures) SECTION R:

More information

Isolated Power Systems E900 Series

Isolated Power Systems E900 Series Isolated Power Systems E900 Series Wall mounted distribution board with integrated single phase isolation transformer, remote alarm indicator, test combination unit and optical on-line insulation fault

More information

Command Center D1260. Owner s Manual

Command Center D1260. Owner s Manual Owner s Manual Command Center D1260 This system includes a telephone line seizure feature. The system may be programmed to communicate with a central monitoring station to report system events. You will

More information

PM Channel Modbus Pyrometer Hub Operator s Guide

PM Channel Modbus Pyrometer Hub Operator s Guide PM180 6-Channel Modbus Pyrometer Hub Operator s Guide The PM180 is a temperature indicator, data logger, alarm unit and configuration tool for Calex infrared temperature sensors. It is compatible with

More information

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this

More information