License Renewal. Long Term Operations of Nuclear Power Plants in the United States. Michael P Gallagher Vice President Exelon License Renewal Projects

Size: px
Start display at page:

Download "License Renewal. Long Term Operations of Nuclear Power Plants in the United States. Michael P Gallagher Vice President Exelon License Renewal Projects"

Transcription

1 License Renewal Long Term Operations of Nuclear Power Plants in the United States Michael P Gallagher Vice President Exelon License Renewal Projects Stockholm, Sweden January 21, 2015

2 Exelon Generation Portfolio IL Wind Quad Cities Byron SE Chicago Exelon City Solar Dresden Braidwood LaSalle Clinton Grande Prairie Falls Fairless Hills Pennsbury OR Wind ID Wind MN Wind Ft. Calhoun (OPPD) West Valley Sunnyside MO Wind Nine Mile Point R. E. Ginna MI Wind Wyman (AM) Oyster Creek Salem (AM) Mystic Fore River Framingham New Boston West Medway Handsome Lake Keystone(AM) Conemaugh (AM) Colver (AM) Limerick Moser Three Mile Island Safe Harbor (AM) Peach Bottom Muddy Run Croydon Delaware Richmond Schuylkill Southwark Eddystone Chester AVSR 1 (In Development) KS Wind SEGS (AM) Nuclear Coal Gas/Oil Intermediate* NM Wind Quail Run Texas Wind Handley Wolf Hollow Colorado Bend Mountain Creek LaPorte Hillabee MD Wind Conowingo Notch Cliff Perryman Philadelphia Road Westport Riverside Gould Street Peakers Renewables (Hydro, Wind, Solar, Landfill Gas) Calvert Cliffs * Eddystone, Handley, Mountain Creek, Mystic and Riverside also have peakers (AM) Asset Management (ownership interest only) (OPPD) Exelon Nuclear Partners operates Ft. Calhoun, a MW plant, under contract with Omaha Public Power District, which owns the facility and its output 2

3 Exelon Operated NPPs 3

4 Key Points 1. Long Term Operations of NPP greater than 40 years is a reality in the United States 2. NPP are safely operated by implementation of the Current Licensing Basis (CLB) and Aging Management Programs 3. Aging Management Programs are maintained current through the use of operating experience and corrective action programs 4. Operating NPP beyond 60 years is technically feasible 5. United States NPP owners are planning to apply for licenses to operate beyond 60 years 4

5 US License Renewal Industry Status 75 units approved; 19 units under NRC review First unit operated beyond 40 years starting in units operating beyond 40 years at end of 2014 Overall Aging Management Programs have been effectively implemented Obtaining Licenses for beyond 60 years is the next step 5

6 Exelon License Renewal Status Original License Date Submitted Approved Renewed License Date Calvert Cliffs 1 &2 July 31, 2014 August 13, 2016 Peach Bottom 2 & 3 Aug 08, 2013 July 02, 2014 April 10, 1998 March 23, 2000 July 31, 2034 August 13, 2036 July 02, 2001 May 07, 2003 Aug 08, 2033 July 02, 2034 Ginna Sept 18, 2009 August 1, 2002 May 19, 2004 Sept 18, 2029 Dresden 2 & 3 Dec 22, 2009 Jan 12, 2011 Quad Cities 1 & 2 Dec 14, 2012 Dec 14, 2012 NMP 1 & 2 Aug 22, 2009 Oct 31, 2026 Jan 03, 2003 Oct 28, 2004 Dec 22, 2029 Jan 12, 2031 Jan 03, 2003 Oct 28, 2004 Dec 14, 2032 Dec 14, 2032 May 27, 2004 Oct 31, 2006 Aug 22, 2029 Oct 31, 2046 Oyster Creek April 09, 2009 July 22, 2005 April 8, 2009 April 09, 2029 TMI 1 April 19, 2014 Jan 08, 2008 Oct 22, 2009 April 19, 2034 Salem 1 & 2 (partially owned; operated by PSEG) Aug 13, 2016 April 18, 2020 Aug 18, 2009 June 30, 2011 Aug 13, 2036 April 18, 2040 Limerick 1 & 2 Oct 26, 2024 June 22, 2029 Byron 1 & 2 Oct 31, 2024 Nov 06, 2026 Braidwood 1 & 2 Oct 17, 2026 Dec 18, 2027 LaSalle 1 & 2 April 17, 2022 Dec 16, 2023 June 22, 2011 Oct 20, 2014 Oct 26, 2044 June 22, 2049 May 29, 2013 May 29, 2013 Dec 9, 2014 Clinton Sept 29, 2026 March 2021 Planned 6

7 License Renewal Rule 10 CFR 54 The License Renewal Rule Safety Application Part 54 Environmental Report Part 51 Application may not be submitted until the plant has operated for 20 years New license can be extended 20 years beyond current license 10 CFR (d): a renewed license can subsequently be renewed Existing rule is adequate and proven for Second License Renewal 7

8 License Renewal Rule Principles The regulatory process is adequate to ensure that the current licensing basis provides an acceptable level of safety, with the possible exception of the detrimental effects of aging on certain systems, structures, and components, and Each plant's current licensing basis is required to be maintained during the renewal term. 8 8

9 License Renewal Aging Management Programs

10 Part 54 Application Integrated Plant Assessment Scope Screen Aging Management Review Systems, components and structures within the scope of 10CFR54: Safety Related Non-Safety Related that could prevent a safety function Regulated Events- SBO, EQ, Fire, PTS, ATWS SCOPE Active Passive Or Active? Passive Periodically Replaced? Yes No Aging Management Review Structures & Components not subject to Additional Aging Management Review Managed by Existing Activities? Yes No Modify existing or add new programs Demonstration that the effects of Aging are adequately managed 10

11 Aging Management program 10 Element Review 1. Scope of Program 2. Preventive Actions 3. Parameters Monitored/Inspected 4. Detection of Aging Effects 5. Monitoring and Trending 6. Acceptance Criteria 7. Corrective Actions 8. Confirmation Process 9. Administrative Controls 10. Operating Experience 11

12 36 Mechanical GALL Aging Management Programs XI.M1 ASME Section XI Inservice Inspection, Subsections IWB, IWC, and IWD XI.M2 Water Chemistry XI.M3 Reactor Head Closure Stud Bolting XI.M4 BWR Vessel ID Attachment Welds XI.M5 BWR Feedwater Nozzle XI.M6 BWR Control Rod Drive Return Line Nozzle XI.M7 BWR Stress Corrosion Cracking XI.M8 BWR Penetrations XI.M9 BWR Vessel Internals XI.M10 Boric Acid Corrosion XI.M11B Cracking of Nickel-Alloy Components and Loss of Material Due to Boric Acid-Induced Corrosion in Reactor Coolant Pressure Boundary Components (PWRs only XI.M12 Thermal Aging Embrittlement of Cast Austenitic Stainless Steel (CASS) XI.M16A PWR Vessel Internals XI.M17 Flow-Accelerated Corrosion XI.M18 Bolting Integrity XI.M19 Steam Generators XI.M20 Open-Cycle Cooling Water System XI.M21A Closed Treated Water Systems. XI.M22 Boraflex Monitoring XI.M23 Inspection of Overhead Heavy Load and Light Load (Related to Refueling) Handling Systems XI.M24 Compressed Air Monitoring XI.M25 BWR Reactor Water Cleanup System XI.M26 Fire Protection XI.M27 Fire Water System XI.M29 Aboveground Metallic Tanks XI.M30 Fuel Oil Chemistry XI.M31 Reactor Vessel Surveillance XI.M32 One-Time Inspection XI.M33 Selective Leaching XI.M35 One-time Inspection of ASME Code Class 1 Small Bore-Piping XI.M36 External Surfaces Monitoring of Mechanical Components XI.M37 Flux Thimble Tube Inspection XI.M38 Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components XI.M39 Lubricating Oil Analysis XI.M40 Monitoring of Neutron-Absorbing Materials Other than Boraflex XI.M41 Buried and Underground Piping and Tanks 12

13 8 Structural & 6 Electrical & 3 TLAA GALL Aging Management Programs Structural XI.S1 ASME Section XI, Subsection IWE XI.S2 ASME Section XI, Subsection IWL XI.S3 ASME Section XI, Subsection IWF XI.S4 10 CFR Part 50, Appendix J XI.S5 Masonry Walls XI.S6 Structures Monitoring XI.S7 RG 1.127, Inspection of Water-Control Structures Associated with Nuclear Power Plants XI.S8 Protective Coating Monitoring and Maintenance Program. Electrical XI.E1 Insulation Material for Electrical Cables and Connections Not Subject to 10 CFR Environmental Qualification XI.E2 Insulation Material for Electrical Cables and Connections Not Subject to 10 CFR Environmental Qualification Requirements Used in Instrumentation Circuits XI.E3 Inaccessible Power Cables Not Subject to 10 CFR Environmental Qualification Requirements XI.E4 Metal Enclosed Bus XI.E5 Fuse Holders XI.E6 Electrical Cable Connections Not Subject to 10 CFR Environmental Qualification Requirements Time Limited Aging Analysis X.M1 Fatigue Monitoring X.S1 Concrete Containment Tendon Prestress X.E1 Environmental Qualification (EQ) of Electric Components 13

14 Developing & Maintaining Effective Aging Management Programs (AMP) Plant Specific OE Industry OE Codes & Standards Research GALL Develop/Modify Aging Management Programs Implement Activities Corrective Action Program NO Criteria Met? YES Continue Monitoring Modify AMP Repair/ Replacement Use of Corrective Action, Operating Experience and ongoing research ensures existing AMPs remain effective for Second License Renewal. 14

15 License Renewal Industry Research for Long Term Operations

16 EPRI Report Assessment of R&D Supporting Aging Management Programs for Long-Term Operations Three categories of AMPs Category 1 R&D support to address knowledge gaps for 60 to 80 years operation to better understand and manage materials performance Category 2 R&D supporting role where aging degradation is well characterized Category 3 No New R&D role identified EPRI & DOE have concluded that there are no generic show stoppers for SLR. Only 8 AMPs were identified as Category 1. This means that the existing AMP is sufficient to detect aging effects and will continue to be improved with ongoing research. 16

17 Materials Category 1 Summary On-Going R&D for Long Term Operations GALL AMP Name Potential LTO Impact on AMP AMP ID XI.M9 BWR Vessel Internals Irradiation and environmental effects on material performance XI.M11B XI.M12 Cracking of Nickel-Alloy Components and Loss of Material Due to Boric Acid-Induced Corrosion in Reactor Coolant Pressure Boundary Components Thermal Aging Embrittlement of Cast Austenitic Stainless Steel (CASS) Environmental effects on material performance Thermal aging and possible irradiation effects on material performance XI.M16A PWR Vessel Internals Irradiation and environmental effects on material X.M31 Reactor Vessel Surveillance Neutron fluence on reactor pressure vessel materials 17

18 Structural & Electrical Category 1 Summary On-Going R&D for Long Term Operations GALL AMP AMP Name Potential LTO Impact on AMP ID XI.S6 Structures Monitoring ASR susceptibility and irradiation effects on material properties GALL AMP AMP Name Potential LTO Impact on AMP ID XI.E1 Insulation Material for Electrical Cables and Connections Not Subject to 10 CFR Environmental Qualification Requirements Combined effects of thermal and radiation exposure XI.E2 Insulation Material for Electrical Cables and Connections Not Subject to 10 CFR Environmental Qualification Requirements Used In Instrumentation Circuits Combined effects of thermal and radiation exposure 18

19 Key Points 1. Long Term Operations of NPP greater than 40 years is a reality in the United States 2. NPP are safely operated by implementation of the Current Licensing Basis (CLB) and Aging Management Programs 3. Aging Management Programs are maintained current through the use of operating experience and corrective action programs 4. Operating NPP beyond 60 years is technically feasible 5. United States NPP owners are planning to apply for licenses to operate beyond 60 years 19

20 License Renewal Questions?

Long Term Operation R&D to Investigate the Technical Basis for Life Extension and License Renewal Decisions

Long Term Operation R&D to Investigate the Technical Basis for Life Extension and License Renewal Decisions Long Term Operation R&D to Investigate the Technical Basis for Life Extension and License Renewal Decisions John Gaertner Technical Executive Electric Power Research Institute Charlotte, North Carolina,

More information

May 2013. Prepared. Srinivasan 1. Prepared

May 2013. Prepared. Srinivasan 1. Prepared Summary of Agingg Management Program Effectiveness Audits to Inform Subsequent Licensee Renewal: R.E. Ginna Nuclear Power Plant and Nine Mile Point Nuclea r Station, Unit 1 May 2013 Prepared by Omesh Chopra,

More information

POLICY ISSUE (INFORMATION)

POLICY ISSUE (INFORMATION) POLICY ISSUE (INFORMATION) October 26, 2011 SECY-11-0149 FOR: FROM: SUBJECT: The Commissioners Eric J. Leeds, Director Office of Nuclear Reactor Regulation SUMMARY FINDINGS RESULTING FROM THE STAFF REVIEW

More information

Robin Dyle. LB60 Workshop February 23, 2011

Robin Dyle. LB60 Workshop February 23, 2011 Materials Degradation Matrix and Issue Management Tables Overview - LTO Update Robin Dyle Technical Executive, EPRI LB60 Workshop February 23, 2011 Introduction Materials Aging Management is Critical to

More information

Published in the Official State Gazette (BOE) number 166 of July 10th 2009 [1]

Published in the Official State Gazette (BOE) number 166 of July 10th 2009 [1] Nuclear Safety Council Instruction number IS-22, of July 1st 2009, on safety requirements for the management of ageing and long-term operation of nuclear power plants Published in the Official State Gazette

More information

Qualification of In-service Inspections of NPP Primary Circuit Components

Qualification of In-service Inspections of NPP Primary Circuit Components Qualification of In-service Inspections of NPP Primary Circuit Components ABSTRACT Matija Vavrouš, Marko Budimir INETEC Institute for nuclear technology Dolenica 28, 10250 Zagreb, Croatia matija.vavrous@inetec.hr,

More information

Deregulation, Consolidation, and Efficiency: Evidence from U.S. Nuclear Power

Deregulation, Consolidation, and Efficiency: Evidence from U.S. Nuclear Power ONLINE DATA APPENDIX Deregulation, Consolidation, and Efficiency: Evidence from U.S. Nuclear Power Lucas W. Davis UC Berkeley and NBER Catherine Wolfram UC Berkeley and NBER February 2012 This study is

More information

Second License Renewal Roadmap. May 2015 Prepared by the Nuclear Energy Institute

Second License Renewal Roadmap. May 2015 Prepared by the Nuclear Energy Institute Second License Renewal Roadmap May 2015 Prepared by the Nuclear Energy Institute Second License Renewal Roadmap May 2015 Prepared by the Nuclear Energy Institute For more information, contact NEI s leads

More information

Business Risks and Opportunities Related to Climate Change. Helen A. Howes Vice President, EH&S Exelon Corporation

Business Risks and Opportunities Related to Climate Change. Helen A. Howes Vice President, EH&S Exelon Corporation 0 Business Risks and Opportunities Related to Climate Change Helen A. Howes Vice President, EH&S Exelon Corporation Presentation Outline Exelon Background Position on Climate Change Legislation Voluntary

More information

white paper Second License Renewal: Nuclear Plant Operations Beyond 60 Years December 2015

white paper Second License Renewal: Nuclear Plant Operations Beyond 60 Years December 2015 white paper Second License Renewal: Nuclear Plant Operations Beyond 60 Years December 2015 The Nuclear Energy Institute is the nuclear energy industry s policy organization. This white paper and additional

More information

Improving regulatory practices through the OECD-NEA Stress Corrosion Cracking and Cable Ageing Project (SCAP)

Improving regulatory practices through the OECD-NEA Stress Corrosion Cracking and Cable Ageing Project (SCAP) Improving regulatory practices through the OECD-NEA Stress Corrosion Cracking and Cable Ageing Project (SCAP) A. Yamamoto a, A. Huerta a, K. Gott b, T. Koshy c a Nuclear Safety Division, OECD Nuclear Energy

More information

Major Market Indicators 1 Commodity Current Week Last Four Weeks Last 52 Weeks Totals

Major Market Indicators 1 Commodity Current Week Last Four Weeks Last 52 Weeks Totals Week of March 2 March 6, 215 Summary of Energy Market Developments Electricity peak prices dropped considerably in the eastern half of the U.S. last week and the March 4-5 snowstorms did not make up the

More information

BEFORE THE ATOMIC SAFETY AND LICENSING BOARD PRE-FILED WRITTEN SUPPLEMENTAL REPLY TESTIMONY OF REGARDING CONTENTION NYS-38 / RK-TC-5

BEFORE THE ATOMIC SAFETY AND LICENSING BOARD PRE-FILED WRITTEN SUPPLEMENTAL REPLY TESTIMONY OF REGARDING CONTENTION NYS-38 / RK-TC-5 United States Nuclear Regulatory Commission Official Hearing Exhibit In the Matter of: Entergy Nuclear Operations, Inc. (Indian Point Nuclear Generating Units and ) ASLBP #: 0-88-0-LR-BD01 Docket #: 0000

More information

Response to NRC Request for Additional Information for the Review of the Fermi 2 License Renewal Application - Set 37

Response to NRC Request for Additional Information for the Review of the Fermi 2 License Renewal Application - Set 37 Vito A. Kaminskas Site Vice President DTE Energy Company 6400 N. Dixie Highway, Newport, MI 48166 Tel: 734.586.6515 Fax: 734.586.4172 Email: kaminskasv@dteenergy.com DTE Ensergy- 10 CFR 54 September 24,

More information

Peach Bottom Atomic Power Station, Units 2 and 3 Renewed Facility Operating License Nos. DPR-44 and DPR-56 NRC Docket Nos.

Peach Bottom Atomic Power Station, Units 2 and 3 Renewed Facility Operating License Nos. DPR-44 and DPR-56 NRC Docket Nos. Exelon Generation 200 Exelo11 Way Kennett Square. PA 19348 www.pxeloncoroi.c cm 10 CFR 50.55a August 13, 2015 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 Peach

More information

Evaluation of recent findings on the integrity of pressurised components in nuclear power plants

Evaluation of recent findings on the integrity of pressurised components in nuclear power plants 4 Reactor safety analyses 4.1 Evaluation of recent findings on the integrity of pressurised components in nuclear power plants Dr. Frank Michel Hans Reck For more than 30 years, GRS has been concerned

More information

How To Improve Nuclear Power Plant Capacity Factor

How To Improve Nuclear Power Plant Capacity Factor 19th International Conference on Nuclear Engineering May 16-19, 2011, Chiba, Japan ICONE19-43791 IMPROVING NUCLEAR POWER PLANT'S OPERATIONAL EFFICIENCES IN THE USA Joseph S. Miller President and Principal

More information

A PROCESS-INHERENT, ULTIMATE-SAFETY (PIUS), BOILING-WATER REACTOR

A PROCESS-INHERENT, ULTIMATE-SAFETY (PIUS), BOILING-WATER REACTOR A PROCESS-INHERENT, ULTIMATE-SAFETY (PIUS), BOILING-WATER REACTOR Charles W. Forsberg Oak Ridge National Laboratory* P.O. Box X Oak Ridge, Tennessee 37831 (615) 574-6783 Summary fcr 1985 American Nuclear

More information

Nuclear Safety Council Instruction number IS- 23 on in-service inspection at nuclear power plants

Nuclear Safety Council Instruction number IS- 23 on in-service inspection at nuclear power plants Nuclear Safety Council Instruction number IS- 23 on in-service inspection at nuclear power plants Published in the Official State Gazette (BOE) No 283 of November 24 th 2009 Nuclear Safety Council Instruction

More information

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001. July 22, 2015

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001. July 22, 2015 UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 July 22, 2015 LICENSEE: Nuclear Operations, Inc. FACILITY: Indian Point Nuclear Generating Unit Nos. 2 and 3 SUBJECT: SUMMARY OF

More information

Boiling Water Reactor Systems

Boiling Water Reactor Systems Boiling Water (BWR) s This chapter will discuss the purposes of some of the major systems and components associated with a boiling water reactor (BWR) in the generation of electrical power. USNRC Technical

More information

How To Clean Up A Reactor Water Cleanup

How To Clean Up A Reactor Water Cleanup General Electric Systems Technology Manual Chapter 2.8 Reactor Water Cleanup System TABLE OF CONTENTS 2.8 REACTOR CLEANUP SYSTEM... 1 2.8.1 Introduction... 2 2.8.2 System Description... 2 2.8.3 Component

More information

APPENDIX CC NUCLEAR WASTE STORAGE

APPENDIX CC NUCLEAR WASTE STORAGE APPENDIX CC NUCLEAR WASTE STORAGE APPENDIX CC NUCLEAR WASTE STORAGE MICHIEL P.H. BRONGERS 1 SUMMARY Nuclear wastes are generated from spent nuclear fuel, dismantled weapons, and products such as radio

More information

Proposed TG Repair of Reinforced Concrete of Existing Nuclear Power Plants (RCTG) Chiara Ferraris, NIST Nate Sauer, Structural Technologies

Proposed TG Repair of Reinforced Concrete of Existing Nuclear Power Plants (RCTG) Chiara Ferraris, NIST Nate Sauer, Structural Technologies Proposed TG Repair of Reinforced Concrete of Existing Nuclear Power Plants (RCTG) Chiara Ferraris, NIST Nate Sauer, Structural Technologies Status Over 100 NPP in service today and most of them have reached

More information

Decommissioning situation of Nuclear Power Plant in Japan

Decommissioning situation of Nuclear Power Plant in Japan Decommissioning situation of Nuclear Power Plant in Japan April, 2015 The Japan Atomic Power Co. The Kansai Electric Power Co., Inc. General Description 1 Operational years of commercial NPP in Japan 40

More information

CODE/NAME ENCL CODE/NAME ENCL

CODE/NAME ENCL CODE/NAME ENCL CATEGORY REGULORY INFORMATION DISTRIBUTi SYSTEM (RIDS) ACCESSION NBR:9804140321 DOC.DATE: 98/04/06 NOTARIZED: NO DOCKET # FACIL:50-269 Oconee Nuclear Station, Unit 1, Duke Power Co. 05000269 50-270 '0conee

More information

BWR Description Jacopo Buongiorno Associate Professor of Nuclear Science and Engineering

BWR Description Jacopo Buongiorno Associate Professor of Nuclear Science and Engineering BWR Description Jacopo Buongiorno Associate Professor of Nuclear Science and Engineering 22.06: Engineering of Nuclear Systems 1 Boiling Water Reactor (BWR) Public domain image by US NRC. 2 The BWR is

More information

OVERVIEW OF THE OPERATING REACTORS BUSINESS LINE. July 7, 2016 Michael Johnson Deputy Executive Director for Reactor and Preparedness Programs

OVERVIEW OF THE OPERATING REACTORS BUSINESS LINE. July 7, 2016 Michael Johnson Deputy Executive Director for Reactor and Preparedness Programs OVERVIEW OF THE OPERATING REACTORS BUSINESS LINE July 7, 2016 Michael Johnson Deputy Executive Director for Reactor and Preparedness Programs Program Overview Bill Dean Director Office of Nuclear Reactor

More information

DOCUMENTATION FOR QUALIFICATION SYSTEM

DOCUMENTATION FOR QUALIFICATION SYSTEM DOCUMENTATION FOR QUALIFICATION SYSTEM MATERIAL GROUP: PRESSURE EQUIPMENT MAINTENANCE, REPAIR INTERNAL CODE OF MATERIAL GROUP: MM10300 New code according the registration on myhome: MMGV03 CPV CODE: 45259000-7,

More information

NDE2015,Hyderabad November 26-28,2015

NDE2015,Hyderabad November 26-28,2015 1 Role of Non Destructive Techniques for Monitoring structural Integrity of Primary Circuit of Pressurized Water Reactor Nuclear Power Plant PK Sharma, P Sreenivas, Reactor Projects Division, Bhabha Atomic

More information

How To Improve Safety At A Nuclear Power Plant

How To Improve Safety At A Nuclear Power Plant OVERVIEW OF THE OPERATING REACTORS BUSINESS LINE August 6, 2015 Michael Johnson Deputy Executive Director for Reactor and Preparedness Programs Program Overview Bill Dean Director Office of Nuclear Reactor

More information

APPENDIX B SUPPLEMENTAL INSPECTION PROGRAM A. OBJECTIVES AND PHILOSOPHY OF THE SUPPLEMENTAL INSPECTION PROGRAM

APPENDIX B SUPPLEMENTAL INSPECTION PROGRAM A. OBJECTIVES AND PHILOSOPHY OF THE SUPPLEMENTAL INSPECTION PROGRAM APPENDIX B SUPPLEMENTAL INSPECTION PROGRAM A. OBJECTIVES AND PHILOSOPHY OF THE SUPPLEMENTAL INSPECTION PROGRAM The supplemental inspection program is designed to support the NRC s goals of maintaining

More information

Contents. Appendices:

Contents. Appendices: Contents A. Introduction... 3 I. Asset Management... 3 II. Nuclear Power... 6 B. Motivation for Research... 8 C. Research Plan and Hypothesis... 9 D. Research Method... 10 I. Overview... 10 II. Establishment

More information

www.klmtechgroup.com TABLE OF CONTENT

www.klmtechgroup.com TABLE OF CONTENT Page : 1 of 45 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT 1.0 SCOPE 2 2.0 CONFLICTS

More information

National Registry of Radiation Protection Technologists P.O. Box 3084 Westerly, RI 02891 (401) 637-4811 (ofc) (401) 637-4822 (fax)

National Registry of Radiation Protection Technologists P.O. Box 3084 Westerly, RI 02891 (401) 637-4811 (ofc) (401) 637-4822 (fax) (Rev. 7/13) National Registry of Radiation Protection Technologists P.O. Box 3084 Westerly, RI 02891 (401) 637-4811 (ofc) (401) 637-4822 (fax) Application for Registration Office Use Only Pd by: _ Ck#:

More information

Supporting New Build and Nuclear Manufacturing in South Africa

Supporting New Build and Nuclear Manufacturing in South Africa ASME Nuclear Codes and Standards Supporting New Build and Nuclear Manufacturing in South Africa Sandton, South Africa, October 7-8, 2008 Session 3 Section III - Component Design and Construction Ralph

More information

Reconsideration of Application of GDC-4 Exclusion of Local Dynamic Effects to Local Debris Generation

Reconsideration of Application of GDC-4 Exclusion of Local Dynamic Effects to Local Debris Generation Reconsideration of Application of GDC-4 Exclusion of Local Dynamic Effects to Local Debris Generation April 2010 In October 1987, General Design Criterion (GDC) 4 in Appendix A to 10 C.F.R. Part 50 was

More information

NEW NUCLEAR POWER PLANTS FOR ONTARIO - THE CONTENDERS - 2008 October

NEW NUCLEAR POWER PLANTS FOR ONTARIO - THE CONTENDERS - 2008 October NEW NUCLEAR POWER PLANTS FOR ONTARIO - THE CONTENDERS - 2008 October (THIS OVERVIEW IS AN UPDATED VERSION OF AN EARLIER ONE THAT WAS PUBLISHED IN THE BULLETIN OF THE CANADIAN NUCLEAR SOCIETY, MARCH 2008,

More information

AoDI. December 9, 2015 NOC-AE-1 5003318 10 CFR 50.90. U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001

AoDI. December 9, 2015 NOC-AE-1 5003318 10 CFR 50.90. U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001 Nuclear Operating Company South Texas Project Electric Generating Station PO. Box 289 W/adsworth, Texas 77483 v/v - December 9, 2015 NOC-AE-1 5003318 10 CFR 50.90 U.S. Nuclear Regulatory Commission Attention:

More information

PMCap Local Thin Area Repair and Restoration Component. for Pressure Retaining Items

PMCap Local Thin Area Repair and Restoration Component. for Pressure Retaining Items by Paul S. Manzon President and John K. Wiedemann Vice President, Engineering PMC Engineering Solutions, Inc. 272 Grubb Rd. Pottstown, PA 19465 ABSTRACT A common method of pressure boundary repair for

More information

Nuclear power plant systems, structures and components and their safety classification. 1 General 3. 2 Safety classes 3. 3 Classification criteria 3

Nuclear power plant systems, structures and components and their safety classification. 1 General 3. 2 Safety classes 3. 3 Classification criteria 3 GUIDE 26 June 2000 YVL 2.1 Nuclear power plant systems, structures and components and their safety classification 1 General 3 2 Safety classes 3 3 Classification criteria 3 4 Assigning systems to safety

More information

-2- Docket No. 50-482. Attachment: E-mail dated March 25, 2002

-2- Docket No. 50-482. Attachment: E-mail dated March 25, 2002 April 11, 2002 MEMORANDUM TO: Stephen Dembek, hief, Section 2 Project Directorate IV Division of Licensing Project Management Office of Nuclear Reactor Regulation FROM: Jack N. Donohew, Senior Project

More information

WWER Type Fuel Manufacture in China

WWER Type Fuel Manufacture in China WWER Type Fuel Manufacture in China Yang Xiaodong P.O. Box 273, CJNF, YiBin City, Sichuan, China, [Fax: (+86)8318279161] Abstract: At CJNF, a plan was established for implementation of technical introduction

More information

Electric Market National Overview

Electric Market National Overview Electric Market Overview Electric Market National Overview 1122 Electric Market Overview: Generation Output and Temperatures Page 2 of 8 Weekly U.S. Electric Generation Output and Temperatures Electric

More information

Introductions: Dr. Stephen P. Schultz

Introductions: Dr. Stephen P. Schultz Introductions: Dr. Stephen P. Schultz Vienna, Austria 1 3 September 2015 Work Experience Current Member Advisory Committee on Reactor Safeguards, U.S. Nuclear Regulatory Commission, 12/2011 Chair, Fukushima

More information

www.universityquestions.in

www.universityquestions.in DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK SUBJECT: ME6701-POWER PLANT ENGINEERING YEAR/SEM: III/V UNIT-I COAL BASED THERMAL POWER PLANTS 1. What are the processes of rankine cycle?

More information

APPENDIX L ELECTRICAL UTILITIES

APPENDIX L ELECTRICAL UTILITIES APPENDIX L ELECTRICAL UTILITIES Li Lii APPENDIX L ELECTRICAL UTILITIES GERHARDUS H. KOCH PH.D. 1 SUMMARY AND ANALYSIS OF RESULTS Corrosion Control and Prevention The total cost of electricity sold in the

More information

UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION OFFICE OF NEW REACTORS WASHINGTON, DC 20555-0001.

UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION OFFICE OF NEW REACTORS WASHINGTON, DC 20555-0001. UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION OFFICE OF NEW REACTORS WASHINGTON, DC 20555-0001 December 2, 2010 NRC INFORMATION NOTICE 2010-26: SUBMERGED ELECTRICAL CABLES

More information

Application for Registration

Application for Registration (Rev. 4/09) National Registry of Radiation Protection Technologists P.O. Box 3084, Westerly, RI 02891 (401) 637-4811 Application for Registration Instructions: Type or print neatly in black ink Date: /

More information

The World Nuclear Supply

The World Nuclear Supply The World Nuclear Supply Chain An Overview Greg KASER Staff Director NEA International WPNE Workshop Paris 11 March 2014 Outline of Presentation 1. About WNA 2. Value of: New construction Early dismantlement

More information

Chesapeake Section AWWA Symposium

Chesapeake Section AWWA Symposium PRESTRESSED CONCRETE CYLINDER PIPE (PCCP) Chesapeake Section AWWA Symposium HANSON PRESSURE PIPE Steve Smith January 16,2014 Interpace Projects with Problems INTERPACE 45 MILLION FEET 11,500 PROJECTS Slide

More information

Prestressed Concrete Pipe Fitness for Service and Repair

Prestressed Concrete Pipe Fitness for Service and Repair Prestressed Concrete Pipe Fitness for Service and Repair Rasko Ojdrovic rpojdrovic@sgh.com 781-907-9231 IAEA - EPRI 15 October 2014 www.sgh.com SGH Pipeline Experience More than 25 years of research, analysis,

More information

NORTH CAROLINA EASTERN MUNICIPAL POWER AGENCY SHEARON HARRIS NUCLEAR POWER PLANT, UNIT 1. Renewed License No. NPF-63

NORTH CAROLINA EASTERN MUNICIPAL POWER AGENCY SHEARON HARRIS NUCLEAR POWER PLANT, UNIT 1. Renewed License No. NPF-63 CAROLINA POWER & LIGHT COMPANY NORTH CAROLINA EASTERN MUNICIPAL POWER AGENCY DOCKET NO. 50-400 SHEARON HARRIS NUCLEAR POWER PLANT, UNIT 1 RENEWED FACILITY OPERATING LICENSE 1. The Nuclear Regulatory Commission

More information

2014 Summary Annual Report

2014 Summary Annual Report 2014 Summary Annual Report 1 Table of Contents Table of Contents Letter to Shareholders 3 Innovation 13 Our Brand Pillars 7 Our Companies 14 Our Mission 8 Our Leadership 35 Our Vision / Values 9 Stock

More information

CEP Discussion: AREVA s SONGS-Specific Used Fuel Solution

CEP Discussion: AREVA s SONGS-Specific Used Fuel Solution CEP Discussion: AREVA s SONGS-Specific Used Fuel Solution AREVA TN October, 14, 2014 Dr. Michael V. McMahon, Sr. VP AREVA TN Americas AREVA TN AREVA s SONGS-Specific Solution Topical Outline 1. Overview

More information

INTRODUCTION. Three Mile Island Unit 2

INTRODUCTION. Three Mile Island Unit 2 INTRODUCTION here was an accident at Three Mile Island Unit 2 on March 28,1979. It caused extensive damage to the plant's nuclear fuel core. Most of the plant's major systems were relatively undamaged.

More information

Structural Integrity and NDE Reliability II

Structural Integrity and NDE Reliability II Structural Integrity and NDE Reliability II Preparing for EPR TM Reactor Vessel Inspection J. Laube, AREVA NDE Solutions / intelligendt, Germany Y. Bouveret, AREVA NDE Solutions / Intercontrole, France

More information

CURRENT EXPERIENCE IN TYPICAL PROBLEMS AND FAILURES WITH BOILER PIPING COMPONENTS AND SUPPORTS

CURRENT EXPERIENCE IN TYPICAL PROBLEMS AND FAILURES WITH BOILER PIPING COMPONENTS AND SUPPORTS A DB RILEY TECHNICAL PUBLICATION CURRENT EXPERIENCE IN TYPICAL PROBLEMS AND FAILURES WITH BOILER PIPING COMPONENTS AND SUPPORTS by James P. King, Design Manager DB Riley, Inc. Presented at the 1998 ASME

More information

15823 N. Barkers Landing Houston, TX 77079 281/556 8774 david.hendrix@hghouston.com www.hghouston.com

15823 N. Barkers Landing Houston, TX 77079 281/556 8774 david.hendrix@hghouston.com www.hghouston.com D a v i d E. H e n d r i x, P. E. RESUME 15823 N. Barkers Landing Houston, TX 77079 281/556 8774 david.hendrix@hghouston.com www.hghouston.com Experience: 2013 1990 President, The Hendrix Group Inc., A

More information

Electric Power Systems An Overview. Y. Baghzouz Professor of Electrical Engineering University of Nevada, Las Vegas

Electric Power Systems An Overview. Y. Baghzouz Professor of Electrical Engineering University of Nevada, Las Vegas Electric Power Systems An Overview Y. Baghzouz Professor of Electrical Engineering University of Nevada, Las Vegas Overview Power Generation Conventional power generation Power generation from renewables

More information

BODY OF KNOWLEDGE API-653 ABOVEGROUND STORAGE TANK INSPECTOR CERTIFICATION EXAMINATION November 2015, March 2016 and July 2016 (Replaces October 2013)

BODY OF KNOWLEDGE API-653 ABOVEGROUND STORAGE TANK INSPECTOR CERTIFICATION EXAMINATION November 2015, March 2016 and July 2016 (Replaces October 2013) BODY OF KNOWLEDGE API-653 ABOVEGROUND STORAGE TANK INSPECTOR CERTIFICATION EXAMINATION November 2015, March 2016 and July 2016 (Replaces October 2013) API Authorized Aboveground Storage Tank Inspectors

More information

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley. Sample Questions REVISED FIRST CLASS PARTS A1, A2, AND A3 (NOTE: these questions are intended as representations of the style of questions that may appear on examinations. They are not intended as study

More information

Long term operation integrated processes for delivering extended asset performance

Long term operation integrated processes for delivering extended asset performance Long term operation integrated processes for delivering extended asset performance 15 04 2015 Agenda 1. Introduction 2. Long term operation process for delivery 3. Business planning and key assumptions

More information

This document is the property of and contains Proprietary Information owned by Westinghouse Electric Company LLC and/or its subcontractors and

This document is the property of and contains Proprietary Information owned by Westinghouse Electric Company LLC and/or its subcontractors and This document is the property of and contains Proprietary Information owned by Westinghouse Electric Company LLC and/or its subcontractors and suppliers. It is transmitted to you in confidence and trust,

More information

Gary L. Stevens, P.E. Senior Materials Engineer

Gary L. Stevens, P.E. Senior Materials Engineer NRC000227 Submitted: August 10, 2015 Gary L. Stevens, P.E. Senior Materials Engineer Education MS, Mechanical Engineering, San Jose State University, San Jose, CA, 1991 BS, Mechanical Engineering, California

More information

UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION WASHINGTON, DC 20555-0001. June 16, 2011

UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION WASHINGTON, DC 20555-0001. June 16, 2011 UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION WASHINGTON, DC 20555-0001 June 16, 2011 NRC INFORMATION NOTICE 2011-12: REACTOR TRIPS RESULTING FROM WATER INTRUSION INTO

More information

List of Frequently Utilized Storage Tank Standards and Practices

List of Frequently Utilized Storage Tank Standards and Practices List of Frequently Utilized Storage Tank Standards and Practices Below is a list of frequently used storage tank standards and practices from organizations that are referenced in 25 PA Code, Chapter 245.

More information

This occurrence is considered to be of no significance with respect to the health and safety of the public.

This occurrence is considered to be of no significance with respect to the health and safety of the public. Serial No. MNS-15-072 September 10, 2015,. DUKESteven Vice D. President Capps, ENERGYMcGuire Nuclear Station Duke Energy MGOIVP 1 12700 Hagers Ferry Road Huntersville, NC 28078 0: 980.875.4805 f: 980.875.4809

More information

49 CFR 192 Transportation of Natural and Other Gas By Pipeline: Minimum Federal Safety Standards

49 CFR 192 Transportation of Natural and Other Gas By Pipeline: Minimum Federal Safety Standards 49 CFR 192 Transportation of Natural and Other Gas By Pipeline: Minimum Federal Safety Standards THIS DOCUMENT CONTAINS ONLY THE SECTIONS NEEDED FOR THE API 1169 ICP EXAMS Subpart G General Construction

More information

Office Of Nuclear Energy Light Water Reactor Sustainability Program Annual Review Meeting

Office Of Nuclear Energy Light Water Reactor Sustainability Program Annual Review Meeting Office Of Nuclear Energy Light Water Reactor Sustainability Program Annual Review Meeting Online Monitoring of Material Aging and Degradation Vivek Agarwal Idaho National Laboratory September 16-18, 2014

More information

August 8, 2013 SUMMARY OF JULY 24, 2013 MEETING WITH OMAHA PUBLIC POWER DISTRICT

August 8, 2013 SUMMARY OF JULY 24, 2013 MEETING WITH OMAHA PUBLIC POWER DISTRICT UNITED STATES NUCLEAR REGULATORY COMMISSION REGION I V 1600 EAST LAMAR BLVD ARLINGTON, TEXAS 76011-4511 August 8, 2013 LICENSEE: FACILITY: SUBJECT: Omaha Public Power District (OPPD) Fort Calhoun Station

More information

Piping Systems for Nuclear Power Industry. Prague, October 2011

Piping Systems for Nuclear Power Industry. Prague, October 2011 Piping Systems for Nuclear Power Industry Prague, October 2011 Introduction of the company Leading Czech supplier of piping systems for power engineering 60 years of experience in the field of power industry

More information

Renewable Energy Research

Renewable Energy Research Renewable Energy Research Georgia Power and Southern Company have been active in renewable energy research for many years. Over the last five years we have invested six million dollars in renewable energy

More information

Chemical Decontamination and Fluid Handling Services

Chemical Decontamination and Fluid Handling Services Chemical Decontamination and Fluid Handling Services Westinghouse is a global industry expert in decontamination and fluid handling processes, with proven abilities in decontamination and remediation work.

More information

Advanced Monitoring and Diagnostics:

Advanced Monitoring and Diagnostics: Advanced Monitoring and Diagnostics: Experience at Luminant and the Benefits of Industry Collaboration Presented by Presenter Name/s Presented by: Clinton Carter, Director, Operations Services Charles

More information

Spill Prevention, Control and Countermeasure Plan (SPCC) Program

Spill Prevention, Control and Countermeasure Plan (SPCC) Program United States Environmental Protection Agency Office of Emergency Management August 2013 www.epa.gov/emergencies Spill Prevention, Control and Countermeasure Plan (SPCC) Program Bulk Storage Container

More information

Standard Review Plan for Renewal of Specific Licenses and Certificates of Compliance for Dry Storage of Spent Nuclear Fuel

Standard Review Plan for Renewal of Specific Licenses and Certificates of Compliance for Dry Storage of Spent Nuclear Fuel NUREG-1927 Revision 1 Standard Review Plan for Renewal of Specific Licenses and Certificates of Compliance for Dry Storage of Spent Nuclear Fuel Final Report Office of Nuclear Material Safety and Safeguards

More information

Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com

Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com Portland Area PO Box 665 West Linn, OR 97068 Ph: (503) 650-6957 Salem Area 5434 River Rd. N; #192 Keizer, OR 97303 Ph: (503) 362-5809

More information

Olkiluoto 3 Project June 2010

Olkiluoto 3 Project June 2010 Olkiluoto 3 Project June 2010 Author: R&S Communications Department, La Défense, France. The reproduction, transmission or use of this document or its contents is not permitted without express written

More information

Steel Tank Institute AST Inspections. Dana Schmidt, PE STI/SPFA

Steel Tank Institute AST Inspections. Dana Schmidt, PE STI/SPFA Steel Tank Institute AST Inspections Dana Schmidt, PE STI/SPFA Agenda Brief review of SPCC Rule SPCC relevance to small tanks and small facilities. SP001 Standard for Inspection of Aboveground Storage

More information

Physics and Engineering of the EPR

Physics and Engineering of the EPR Physics and Engineering of the EPR Keith Ardron UK Licensing Manager, UK Presentation to IOP Nuclear Industry Group Birchwood Park, Warrington UK, November 10 2010 EPRs in UK EPR is Generation 3+ PWR design

More information

GENERAL PROPERTIES //////////////////////////////////////////////////////

GENERAL PROPERTIES ////////////////////////////////////////////////////// ALLOY 625 DATA SHEET //// Alloy 625 (UNS designation N06625) is a nickel-chromium-molybdenum alloy possessing excellent resistance to oxidation and corrosion over a broad range of corrosive conditions,

More information

Outlook for RWE s nuclear operations. Prof. Dr. Gerd Jäger London, 16 January 2012

Outlook for RWE s nuclear operations. Prof. Dr. Gerd Jäger London, 16 January 2012 Outlook for RWE s nuclear operations Prof. Dr. Gerd Jäger London, 16 January 2012 Overview of German nuclear power plants Power plant Net capacity MW Commercial commissioning Shutdown German nuclear power

More information

Performance Monitoring of Systems and Active Components

Performance Monitoring of Systems and Active Components CGI Report 06:21 Aging Management Briefing Report Performance Monitoring of Systems and Active Components August 2006 Frank Gregor, P.E. Alan Chockie Prepared for The Petroleum Safety Authority Norway

More information

Maximizing Boiler Plant Efficiency. Presenter: Dan Watkins, LEED BD+C Sales Engineer Bornquist, Inc.

Maximizing Boiler Plant Efficiency. Presenter: Dan Watkins, LEED BD+C Sales Engineer Bornquist, Inc. Maximizing Boiler Plant Efficiency Presenter: Dan Watkins, LEED BD+C Sales Engineer Bornquist, Inc. Efficient Boiler Design Boiler Types Efficiency Definition Non-Condensing Condensing Maximizing Efficiency

More information

Ontario Power Generation Pickering Fuel Channel Fitness for Service. August 2014

Ontario Power Generation Pickering Fuel Channel Fitness for Service. August 2014 Ontario Power Generation Pickering Fuel Channel Fitness for Service August 2014 2 Pickering Fuel Channel Fitness For Service Report 1.0 Introduction The purpose of any power station, regardless of type

More information

3.9.2 Dynamic Testing and Analysis of Systems, Components, and Equipment

3.9.2 Dynamic Testing and Analysis of Systems, Components, and Equipment 3.9.2 Dynamic Testing and Analysis of Systems, Components, and Equipment The U.S. EPR systems, components, and equipment retain their structural and functional integrity when subjected to dynamic loads

More information

Dynamic Behavior of BWR

Dynamic Behavior of BWR Massachusetts Institute of Technology Department of Nuclear Science and Engineering 22.06 Engineering of Nuclear Systems Dynamic Behavior of BWR 1 The control system of the BWR controls the reactor pressure,

More information

Ethanol Vehicle and Infrastructure Codes and Standards Citations

Ethanol Vehicle and Infrastructure Codes and Standards Citations Ethanol Vehicle and Infrastructure Codes and Standards Citations This document lists codes and standards typically used for U.S. ethanol vehicle and infrastructure projects. To determine which codes and

More information

PVNGS License Renewal Application Metal Fatigue Topics. April 1, 2010

PVNGS License Renewal Application Metal Fatigue Topics. April 1, 2010 PVNGS License Renewal Application Metal Fatigue Topics April 1, 2010 Discussion Topics Historical and general background Metal Fatigue Monitoring Program Cycle Counting Questions Class 1 Fatigue TLAA Evaluation

More information

ATI 2205 ATI 2205. Technical Data Sheet. Duplex Stainless Steel GENERAL PROPERTIES. (UNS S31803 and S32205)

ATI 2205 ATI 2205. Technical Data Sheet. Duplex Stainless Steel GENERAL PROPERTIES. (UNS S31803 and S32205) ATI 2205 Duplex Stainless Steel (UNS S31803 and S32205) GENERAL PROPERTIES ATI 2205 alloy (UNS S31803 and/or S32205) is a nitrogen-enhanced duplex stainless steel alloy. The nitrogen serves to significantly

More information

Dominion. Dan Weekley Vice President, Corporate Affairs. Dan Stoddard Senior Vice President, Nuclear Operations. March 24, 2016

Dominion. Dan Weekley Vice President, Corporate Affairs. Dan Stoddard Senior Vice President, Nuclear Operations. March 24, 2016 Dominion Dan Weekley Vice President, Corporate Affairs Dan Stoddard Senior Vice President, Nuclear Operations March 24, 2016 Dominion Profile Power and Natural Gas Infrastructure Overview Leading provider

More information

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL ELECTRODE BOILERS WITH JET-FLO Technology VAPOR POWER INTERNATIONAL ELECTRODE boilers The Electrode Steam Boiler with Jet-Flo technology consists of an insulated pressure vessel and is fully enclosed in

More information

Boiling Water Reactor Basics

Boiling Water Reactor Basics Boiling Water Reactor Basics Larry Nelson November 2008 Overview Big Picture - BWR Plants Major Components BWR Evolution BWR Features vs. PWR Features Electrochemical Potential (ECP) Concept ECP Monitoring

More information

5. State the function of pulveriser. The pulverisers are the equipments which are used to powdered coal.

5. State the function of pulveriser. The pulverisers are the equipments which are used to powdered coal. 413 POWER PLANT ENGINEERING PART-A 1. Define Power. Power is the rate at which energy is used (or) Energy/time. 2. What are the types of fuels? Solid fuel Liquid fuel Gaseous fuel (Any one among the above

More information

External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902

External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902 External Wrapping of Steel Riser Pipe Case Study HJ3 CS200902 Introduction Refineries process a wide variety of petroleum products. As part of the process, they rely on cooling towers, which recycle water

More information

ALLOY C276 DATA SHEET

ALLOY C276 DATA SHEET ALLOY C276 DATA SHEET //// Alloy C276 (UNS designation N10276) is a nickel-molybdenum-chromium-iron-tungsten alloy known for its corrosion resistance in a wide range of aggressive media. It is one of the

More information

Building New Generation Nuclear Plants Worldwide : AREVA's Experience

Building New Generation Nuclear Plants Worldwide : AREVA's Experience Building New Generation Nuclear Plants Worldwide : AREVA's Experience Philippe Guay Senior Vice President, New Builds Offers AREVA 37 th WNA Symposium 12-14 September 2012 LONDON Projects status The value

More information

Wall Thinning Trend Analyses for Secondary Side Piping of Korean NPPs

Wall Thinning Trend Analyses for Secondary Side Piping of Korean NPPs Transactions of the 17 th International Conference on Structural Mechanics in Reactor Technology (SMiRT 17) Prague, Czech Republic, August 17 22, 2003 Wall Thinning Trend Analyses for Secondary Side Piping

More information