2 Expanded Polystyrene (EPS) Introduction Expanded Polystyrene is a polymer impregnated with a foaming agent which, when exposed to steam, creates a uniform closed cell structure highly resistant to heat flow and moisture penetration. This in-plant expansion process is fused into blocks which are cured for dimensional stability and cut into boards. Due to its low cost per board foot, EPS is an excellent material for all construction applications. Dependable Performance The foaming agent used in the manufacture of EPS foam is replaced by air during the curing process resulting in uniform, longterm, dependable thermal performance. Advantages Low material and installation cost. Easy to handle and apply Provides an excellent surface for plastic base. Excellent bond with drywall and other panel type adhesives. Resists moisture penetration. Available in wide range of sizes. Available in various densities. EIFS approved. Specifications Expanded Polystyrene boards meet the product requirements established by current building codes and the following specifications, Standards and Approvals ASTM C Factory Mutual (FM) 4651 Underwriters Laboratories (UL) R-9699 ICC-ES NER 667 Availability EPS foam is available in a wide variety of sizes and densities to accommodate all applications. Available Sizes Thickness: 1/2 to 37 Length: 2 to 16 Width: 2 to 72 Adequate Strength Under normal conditions the compressive strength provided by EPS boards usually exceeds most design requirements. When dictated by load conditions, board densities may be increased to meet allowable working stresses. Typical Physical Properties of Thermal Foam EPS Board PROPERTY 1 UNITS ASTM TEST TYPE XI TYPE I TYPE VIII TYPE II TYPE IX Density Min lb/ft 3 C Thermal Resistance Min R for C-177 or 25 F (-3.9 C) 1 inch F (4.4 C) thickness F (23.9 C) F (43.3 C) Compressive Resistance Min psi D at Yield or 10% Deformation Flexural Strength Min psi C Water Vapor Permeability Max perm-in E Water Absorption % by Vol Max C Dimensional Stability Max % Oxygen Index Min % D Flame Spread Smoke Developed See ASTM C Standard Specification for complete information. 2 See UL Certificate Thermal Foam 1 (R-9699) reference available from Thermal Foams, Inc. / Buffalo NY * Warning: Thermal Foam EPS is combustible and will burn and should not be exposed to fire or flame. Thermal Foam EPS should be covered with an ignition barrier such as a minimum of 1/2 drywall and not used in exposed applications.

3 Foundation Wall Applications Perimeter Insulation Thermal Foam Expanded Polystyrene is excellent when used for perimeter and slab edge insulation. It is resistant to water and water vapors. It does not rot or decay. It does not support fungus. EPS provides long term dependable resistance to heat loss. Vertical Application Thermal Foam Expanded Polystyrene foam is placed against the foundation wall. As work progresses, foam is held in place with back fill. A suitable adhesive can also be used. Horizontal Application Thermal Foam is placed on a level, well drained, well tamped ground. The entire concrete slab is then poured. Polyethylene film should be used as a vapor barrier. Block Masonry Fill To meet energy conservation standards for masonry foundation walls, granulated Thermal Foam EPS Blockfill may be placed within the core of the concrete block. Unheated Slabs Heated Slabs Winter degree days Width of Insulation EPS Thickness R/inch Winter degree days Width of Insulation EPS Thickness R/inch or less to / or more or less to / to / to or more /2

4 Foundation Wall Applications Drywall Base Thermal Foam Expanded Polystyrene Foam can be applied directly to any masonry surface. Due to it s high resistance to moisture transmission, no vapor barrier is required for the EPS foam. Local codes should be followed for vapor barrier requirements. This type of installation eliminates costly furring and lathing. It s excellent insulation properties help keep heating costs low in winter and cooling costs low in summer. Specially fabricated metal channels are available for attaching Thermal Foam EPS foam to masonry walls. Drywall is then easily screwed to metal channels. Minimum 1/2 drywall can be applied directly to the foam providing for a completely insulated interior. 1/2 Drywall Typical U and R Values Wall Construction No 1 tk EPS 2 tk EPS Insulation 8 concrete U Block R Concrete U Block R Brick and U Concrete Block R Brick and U Cinder Block R U -- BTU/hr - sq. ft. - F R -- 1/U Cavity Wall Insulation The most important function of Thermal Foam Expanded Polystyrene Foam when used for cavity wall construction is controlling water vapor transmission and heat loss. Due to it s superior thermal properties, Thermal Foam EPS can be used with excellent success. The insulation can be placed against the inner vertical surface and secured with wall ties or bonded with a suitable adhesive. For optimum resistance to moisture penetration from exterior sources, maintain a minimum 1/2 air space between the foam insulation and outer vertical surface. Typical U and R Values Wall Construction No Insulation 1 tk EPS 2 tk EPS 8 concrete U Block R Concrete U Block R Brick and U Concrete Block R U -- BTU/hr - sq. ft. - F R -- 1/U

5 Backers for Exterior Siding Remodeling of an existing residential or commercial buildings requires re-insulation of exterior walls to guard against rising fuel cost. Aluminum, Vinyl and Steel siding coupled with Thermal Foam EPS backer board has long been recognized as the industry standard. It absorbs shock which helps to reduce damage to siding. It s low thermal conductivity factor (K Factor) offers superior insulation values at a low installed price. It is light in weight and easily installed at the job site. R-Plus Exterior Sheathing Thermal Foam Type IX Sheathing is a nonstructural insulation board widely used in residential construction. When used in place of conventional sheathing and construction of an interior studded wall insulated with fiberglass it will provide for a totally insulated house. The minor increase of material cost is offset by the overall comfort of the house plus conserving expensive energy consumption. Thermal Foam Sheathing offers excellent insulation values. It s inexpensive to install and resists moisture absorption. Sizes available: 3/4 x 24 x R x 24 x R /2 x 24 x R 6.3 Construction Procedures 1. Framing must be braced to meet code requirements. Diagonal let-in bracing and stud straps can be used because it provides a flush surface for foam sheathing. 2. Nails must be at least 1/2 longer than thickness of foam sheathing. 3. Sheathing must be applied horizontally with vertical joints meeting at studs. 4. Protect bottom edge of foam with wood nailer. 5. Cover foam sheathing with exterior finish as soon as possible. Foam should not be exposed to the sun s rays for a long period of time.

6 Special Applications Roof Insulation Thermal Foam Expanded Polystyrene insulation is used in a wide range of roof applications. It is well suited to both new and re-roof systems. It is used in asphalt build-up systems, as well as single ply membrane systems. Thermal Foam closed cell structure prevents excessive moisture from entering the foam, thereby minimizing harmful blistering in build-up roofs. Its light weight speeds up installation and reduces roof load weight. Board sizes are 4 ft. x 4 ft. and 4 ft. x 8 ft. in thickness from 3/4 to 37. Tapered Roof Insulation Systems or Saddle and Cricket Assemblies are our specialty. Thermal Foam is UL and FM approved and listed for various roofing assemblies. Please consult with a Thermal Foams representative or the current UL and FM approval guides. Comparison Chart Specified Conductance (C) Resistance (R) Thermal Foam (2) Fiber Board Thickness Perlite Polyisocyanurate Glass Fiber /4 3-1/ / /2 2-1/2 2-1/ / / / /2 1-1/2-1-1/16 Notes: Thermal Foam thickness based on typical R value range at 40 F mean temperature and 4.2 per inch per ASTM C Type I. Cold Storage When used in Cold storage applications Thermal Foam EPS offers advantages such as light weight, water resistance, and it will not rot or decay. A highly efficient foam insulation providing medium permeability and a porous interior finish is the ideal combination for low vapor flow and optimum condensation control. Various densities are available to support heavy floor loads. Pre-laminated, FRP Faced, SIP (Structural Insulated Panels) are available. Being light in weight and easily fabricated, column fittings and cut-outs can be made with simple hand tools. Cost is reduced because foam insulation can be easily applied to substrates in single or multi-layer construction. It permits direct application of plastic and other finishes. Costly furring can be eliminated. When Thermal Foam EPS insulation is installed in accordance with recommended practices long term performances and thermal efficiency will last for the life of the project. Typical Thicknesses ~ Thermal Foam EPS Insulation Operating Temperature F Insulation Thickness U Factor BTU (Hr.) (Sq. Ft.) (F ) *Colder Temperatures not recommended Note: Climatic conditions, local design temperature, building orientation, operating conditions, etc., can affect the insulation thickness required. It is therefore recommended that a study to determine the optimum thickness for each project be performed by a qualified professional.

7 Ceiling Tile Thermal Tile is a decorative, light weight, lay in panel for a suspended ceiling. It is approved by Factory Mutual when installed beneath an automatic sprinkler system. It s high insulation value makes it an excellent energy saving installation. It s decorative, economical and cost efficient. Thermal Tile is not recommended for residential applications. *See warning below. Sizes available: 1 x 23-3/4 x 47-3/ pcs. per ctn sq. ft. - Square Edge or Revealed Edge. 1/2 x 23-3/4 x 47-3/ pcs. per ctn sq. ft. - Square Edge or Revealed Edge. Packaging Light weight, shock absorbent, strong, dust free, are just a few reasons why fabricated Thermal Foam Expanded polystyrene is widely used for packaging. It can be molded in densities as low as 0.8 PCF, and as high as 2.5 PCF. Because it is lighter than corrugated it saves on expensive shipping cost. Whether it s simple squares or complicated cut outs, Thermal Foam EPS is an economical answer because there are minimal tooling costs compared to shape molding. Attic and Crawl Spaces Thermal Foam EPS boards are permitted to be used in attics and crawl spaces without protective coverings required under of the 1999 Standard Building Code, Section of the BOCA National Building Code/1999, Section of the 1997 Uniform Building Code, Section of the 1998 One- and Two-Familly Dwelling Code, Section of the 2000 International Building Code, and Section R of the 2000 International Residential Code. Thermal Foam EPS Boards (2 inch maximum thickness and maximum 2.00 lb/ft 3 density, or 5 inch maximum thickness and maximum 1.00 lb/ft 3 density) are permitted to be installed exposed in attics or crawl spaces that are used only for service of utilities. Thermal Foam EPS boards as described above are permitted to be installed without the ignition protective coverings under the following conditions: Entry to the attic or crawl space is limited to service of utilities. There are no interconnected attic or crawl space areas. Air in the attic or crawl space is not circulated to other parts of the building. The board thicknesses and densities are limited as stated above. Ventilation of the attic or crawl space is provided in accordance with the applicable code. Insulating Properties Definition K / Thermal Conductivity The measurement of heat flow through one-inch thickness of any single material per hour x square foot x F K -- BTU/ (hr.) (sq. ft.) ( F/ inch) C / Thermal Conductance The measurement of heat flow through any single material that is more or less than one inch thick. C --K/ thickness R Factor / Thermal Resistance Reciprocal of the materials C R -- 1/C U Factor The measurement in BTU of heat flow, per hour - square foot ( F) through a combination of materials. U -- BTU/ (hr.) (sq. ft.) ( F) U -- 1/R * Warning: Thermal Foam EPS is combustible and will burn and should not be exposed to fire or flame. Thermal Foam EPS should be covered with an ignition barrier such as a minimum of 1/2 drywall and not used in exposed applications.

8 2101 Kenmore Avenue Buffalo, NY Buffalo: (716) Rochester: (585) Fax: (716) South Bay Road PO BOX 1981 Cicero, NY (315) Fax: (315) Website: Though the information presented in this literature is offered in good faith and believed to be accurate, ALL STATEMENTS AND SUGGESTIONS ARE MADE WITHOUT WARRANTY, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OF FITNESS FOR ANY PURPOSE. The typical values contained herein are properties believed to be representative of all EPS insulation meeting ASTM C specifications, and were obtained using test specimens prepared in the laboratories of NOVA Chemicals, Inc., Huntsman Corporation, Styrochem International, Inc., and BASF Corporation. Thermal Foams, Inc. or Thermal Foams/Syracuse Inc. should be consulted prior to using Thermal Foam EPS for any and all applications. * Warning: Thermal Foam EPS is combustible and will burn and should not be exposed to fire or flame. Thermal Foam EPS should be covered with a thermal barrier such as a minimum of 1/2 drywall and not used in exposed applications. Copyright Thermal Foams, Inc. 2002

R-Matte Plus-3. Insulation for the Building Envelope ROOF WALL SPECIALTY

R-Matte Plus-3. Insulation for the Building Envelope ROOF WALL SPECIALTY Insulation for the Building Envelope ROOF WALL SPECIALTY PRODUCT DESCRIPTION Rmax R-Matte Plus-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam

More information

ICC-ES Evaluation Report Reissued July 1, 2009 This report is subject to re-examination in two years.

ICC-ES Evaluation Report Reissued July 1, 2009 This report is subject to re-examination in two years. ICC-ES Evaluation Report ESR-1566* Reissued July 1, 2009 This report is subject to re-examination in two years. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council

More information

INSULATION BOARD PRODUCTS

INSULATION BOARD PRODUCTS 529 14 th Street, NW, Suite 750, Washington, DC 20045 Tel 202-591-2466 Fax 202-591-2445 www.xpsa.com Polystyrene-based INSULATION BOARD PRODUCTS SIMILAR BUT VERY DIFFERENT DIFFERENT CONSTRUCTION DIFFERENT

More information

Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature

Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature Thermal Values Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature relative to changing exterior temperatures. By reducing interior temperature

More information

Fire Resistance Bulletin

Fire Resistance Bulletin New 1-hr Rated Exterior Wall Assembly Includes Allowances for Various Insulation Options and Much Wider Maximum Girt Spacing Under the auspices of the MBMA Committee on Fire Protection and Related Insurance

More information

COMMERCIAL BUILDING APPLICATIONS

COMMERCIAL BUILDING APPLICATIONS EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that

More information

Tapered Insulation Systems

Tapered Insulation Systems PIMA Technical Bulletin #108 Tapered Insulation Systems About Polyiso Insulation Polyiso is a rigid foam insulation used in over 70% of commercial roof construction, in commercial sidewall construction

More information

CHAPTER 7: Building Systems ROOFING SYSTEMS

CHAPTER 7: Building Systems ROOFING SYSTEMS ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen

More information

2.18 INTERIOR & EXTERIOR FINISHES 2.18.1 VAPOR & AIR BARRIERS

2.18 INTERIOR & EXTERIOR FINISHES 2.18.1 VAPOR & AIR BARRIERS 2.18 INTERIOR & EXTERIOR FINISHES 2.18.1 VAPOR & AIR BARRIERS The LOGIX wall assembly has no need for an additional vapor barrier, the solid concrete core covered with the low permeance EPS (Type II) foam

More information

Standard Specification for Expanded Polystyrene (EPS) Insulation for Use in Exterior Insulation And Finish Systems

Standard Specification for Expanded Polystyrene (EPS) Insulation for Use in Exterior Insulation And Finish Systems Standard Specification for Expanded Polystyrene (EPS) Insulation for Use in Exterior Insulation And Finish Systems 1.0 Scope 1.1 This specification covers the type, physical properties and dimensions of

More information

SMARTBOARD Roof Board For Roof Assemblies. Designed to protect, strengthen and sustain roof assemblies

SMARTBOARD Roof Board For Roof Assemblies. Designed to protect, strengthen and sustain roof assemblies SMARTBOARD For Roof Assemblies Designed to protect, strengthen and sustain roof assemblies The ADVANTAGE was developed to meet the demands of challenging commercial roof assemblies; moisture/mold (food

More information

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING insulation installed on foundation walls must be separated from the building interior with a code approved thermal barrier. Foam

More information

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS 1. SCOPE 1.1 This specification covers the type, physical properties and dimensions of Expanded Polystyrene Insulation Board intended for use

More information

BUILDING INSULATION 07210

BUILDING INSULATION 07210 This MANU-SPEC«utilizes the Construction Specifications Institute (CSI) Manual of Practice, including MasterFormat«, SectionFormat«and PageFormat«. A MANU-SPEC is a manufacturer-specific proprietary product

More information

Insulation R-Value Comparisons

Insulation R-Value Comparisons Insulation R-Value Comparisons American Ingenuity s component panels for the 22 48 domes contains seven inch thick rigid Expanded Polystyrene (E.P.S.) insulation which has an R value of 28. American Ingenuity

More information

Product Test Summaries

Product Test Summaries Sierra Premium TM Product Test Summaries ASTM C 1185 Physical Properties Tests ASTM E 84/CAN/ULC S102-07 Surface Burning Characteristics ASTM E 228 Physical Properties Tests ASTM E 119/CAN/ULC S101-07

More information

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY Insulation for Above the Deck WALL SPECIALTY PRODUCT DESCRIPTION Rmax Re-Cover Board-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam core bonded

More information

Underwriters Laboratories Testing Information

Underwriters Laboratories Testing Information Underwriters Laboratories Testing Information R-8078 Underwriters Laboratories Inc. R-13173 Classified Spray Fiber Surface burning characteristics applied to inorganic reinforced cement board with a maximum

More information

FOAMULAR LT40, 400 and 600 insulations with minimum compressive strengths of

FOAMULAR LT40, 400 and 600 insulations with minimum compressive strengths of Technical Guide FOAMULAR Extruded Polystyrene Insulation For Cold Storage Applications FOAMULAR extruded polystyrene insulation is suitable for virtually all cold storage insulating needs, including floors,

More information

R-Value and Densities Chart

R-Value and Densities Chart R-Value and Densities Chart Material R-Value Per Inch R-Value Per Unit Inside Air Film 0.68 Air Space between Studs 0.95 Building Pa 0.06 ½ in. Fiberboard Sheathing 1.52 Gypsum Wallboard or Drywall 0.90

More information

Product Guide. Superior Insulation Choices. Continuous Insulation Solutions - Walls - Roofs - Exposed - Specialty - Accessories

Product Guide. Superior Insulation Choices. Continuous Insulation Solutions - Walls - Roofs - Exposed - Specialty - Accessories Product Guide Superior Insulation Choices Continuous Insulation Solutions - Walls - Roofs - Exposed - Specialty - Accessories MAXIMUM CONTROL IN EFFICIENT DESIGN FOR OVER 35 YEARS All The Reasons Why Polyiso

More information

Renovating Your Basement

Renovating Your Basement building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Renovating Your Building America Report - 0309 2003 (revised 2007) Building Science Corporation Abstract:

More information

KOOLFOAM BLACK PEARL. Koolfoam BLACK PEARL Slab Insulation Koolfoam THERMALOCK jointing system EXPANDED POLYSTYRENE

KOOLFOAM BLACK PEARL. Koolfoam BLACK PEARL Slab Insulation Koolfoam THERMALOCK jointing system EXPANDED POLYSTYRENE Koolfoam Slab Insulation Koolfoam THERMALOCK jointing system ADVANTAGES Koolfoam Slab Insulation 20% better thermal performance than white EPS Thinner sheets can be used to achieve relevant R values No

More information

EXPANDED PLASTICS IN BUILDING CONSTRUCTION

EXPANDED PLASTICS IN BUILDING CONSTRUCTION GAP.2.0.2 A Publication of Global Asset Protection Services LLC EXPANDED PLASTICS IN BUILDING CONSTRUCTION INTRODUCTION Because of their excellent thermal insulation properties, foamed plastics have gained

More information

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Built to Last. Built for Beauty. Good. Solid. Logix. TM Built to Last. Built for Beauty. Good. Solid. Logix. TM Quality, Value and Service Introducing LOGIX Insulated Concrete Forms. Based on the simple concept of interlocking blocks, LOGIX ICF gives you a

More information

REPORT HOLDER: STAR R FOAM MANUFACTURING, INC EAST AVENUE F ARLINGTON, TEXAS EVALUATION SUBJECT: STAR R FOAM INSULATION BOARDS

REPORT HOLDER: STAR R FOAM MANUFACTURING, INC EAST AVENUE F ARLINGTON, TEXAS EVALUATION SUBJECT: STAR R FOAM INSULATION BOARDS 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-1566 Reissued 07/2016 This report is subject to renewal 07/2017. DIVISION: 07 00 00 THERMAL

More information

ICC-ES Evaluation Report. ESR-3493 Reissued September 2014 This report is subject to renewal September 2015.

ICC-ES Evaluation Report. ESR-3493 Reissued September 2014 This report is subject to renewal September 2015. ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-3493 Reissued September 2014 This report is subject to renewal September 2015. A Subsidiary of the International Code Council DIVISION:

More information

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability 1/9/13 By Brett T. Fagan, P.E. Presented by Marie Horan, P.E. Building Diagnostics, Inc. Building Diagnostics Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

More information

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003) NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:

More information

TAMKO. TW WINDOW & DOOR FLASH Flashing Membrane PRODUCT DATA

TAMKO. TW WINDOW & DOOR FLASH Flashing Membrane PRODUCT DATA TW WINDOW & DOOR FLASH PRODUCT DATA DESCRIPTION TAMKO is a flexible self-adhering rubberized asphalt flashing membrane with a white polymer surface film and a removable treated release film on the adhesive

More information

Gypsum Board Systems Manual

Gypsum Board Systems Manual CertainTeed Gypsum Board Systems Manual Fire Resistance and Sound Control Design Manual Division 09 GYPSUM BOARD SYSTEMS MANUAL TABLE OF CONTENTS Introduction General Fire Resistance...1 Sound Control...3

More information

SEE JAMB 3/4" 1 1/2" 14 NOTES: 1. SEE DETAIL 1 FOR KEYNOTE MATERIAL DESCRIPTIONS

SEE JAMB 3/4 1 1/2 14 NOTES: 1. SEE DETAIL 1 FOR KEYNOTE MATERIAL DESCRIPTIONS . FACE OF WALL.. STUD CONSTRUCTION WITH FIBERGLASS BATT INSULATION AND FIBERGLASS FACED EXTERIOR GYPSUM SHEATHING WITH JOINTS SEALED USING -PART POLYURETHANE PRIOR TO INSTALLING FLUID APPLIED WEATHER RESISTANT

More information

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed

More information

OUTSTANDING CHARACTERISTICS OF TEKFOIL HI-PERFORMANCE REFLECTIVE INSULATION

OUTSTANDING CHARACTERISTICS OF TEKFOIL HI-PERFORMANCE REFLECTIVE INSULATION OUTSTANDING CHARACTERISTICS OF TEKFOIL HI-PERFORMANCE REFLECTIVE INSULATION Unaffected by ultraviolet rays Environmentally safe Nontoxic Nonallergenic Anti-static Stops air infiltration Better ventilation

More information

TSX Insulation for Exposed Use

TSX Insulation for Exposed Use Insulation for Exposed Use PRODUCT DESCRIPTION Rmax TSX-8500 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (Polyiso) foam core bonded to embossed, glass fiber

More information

LITE-DECK INSULATED CONCRETE FORMS STAY-IN-PLACE FORMS FOR SUPERIOR FLOORS, DECKS AND ROOFS

LITE-DECK INSULATED CONCRETE FORMS STAY-IN-PLACE FORMS FOR SUPERIOR FLOORS, DECKS AND ROOFS LITE-DECK INSULATED CONCRETE FORMS STAY-IN-PLACE FORMS FOR SUPERIOR FLOORS, DECKS AND ROOFS INCREASE COMFORT AND ENERGY EFFICIENCY FROM TOP TO BOTTOM WITH LITE-DECK Lite-Deck is a stay-in-place concrete

More information

SWD URETHANE SPRAYFOAM INSULATION MASTER SPECIFICATION SECTION

SWD URETHANE SPRAYFOAM INSULATION MASTER SPECIFICATION SECTION PART 1 GENERAL SUMMARY SECTION INCLUDES: Spray polyurethane foam insulation and acceptable alternatives as described herein. DESCRIPTION A. Insulation materials shall be ICC approved ½ lb or 2 lb spray

More information

USER S GUIDE. phone: address: 305 E. Elva St. Idaho Falls, ID

USER S GUIDE. phone: address: 305 E. Elva St. Idaho Falls, ID USER S GUIDE Roof Panel Application Guide RAYCORE roof panels are designed to meet the unique roof insulation needs of Log, Timberframe, Post & Beam, and Straw Bale Homes as well as other highly insulated

More information

LISTING INFORMATION OF Alucoil - larson by Alucoil FR 4 mm and 6 mm ACM Panels SPEC ID: 29074. Alucoil North America LLC 1976 Joe Rogers Jr Blvd

LISTING INFORMATION OF Alucoil - larson by Alucoil FR 4 mm and 6 mm ACM Panels SPEC ID: 29074. Alucoil North America LLC 1976 Joe Rogers Jr Blvd LISTING INFORMATION OF Alucoil - larson by Alucoil FR 4 mm and 6 mm ACM Panels SPEC ID: 29074 Alucoil North America LLC 1976 Joe Rogers Jr Blvd Manning, SC 29102 This report is for the exclusive use of

More information

Continuous Insulation Using Polyiso Wall Sheathing

Continuous Insulation Using Polyiso Wall Sheathing PIMA Technical Bulletin #403 Continuous Insulation Using Polyiso Wall Sheathing What it is, what it does, and why you need it About Polyiso Insulation Polyiso is a rigid foam insulation used in over 70%

More information

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.

More information

The Case for Cross Laminated Timber: Part 2

The Case for Cross Laminated Timber: Part 2 Learning Objectives The Case for Cross Laminated Timber: Part 2 Opportunities and Challenges for a New Class of Timber Product 1. Review answers to common questions regarding the design and construction

More information

THE DOW CHEMICAL COMPANY Issued: August 1, 2008 200 LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN 48674 (989) 638-8655 www.dowbuildingmaterials.

THE DOW CHEMICAL COMPANY Issued: August 1, 2008 200 LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN 48674 (989) 638-8655 www.dowbuildingmaterials. ICC EVALUATION SERVICE, INC. EvaluateP InformP Protect Los Angeles Business/Regional OfficeP 5360 Workman Mill RoadP Whittier, CA 90601 (562) 699-0543 phonep (562) 695-4694 fax DIVISION: Section: 6 WOOD

More information

s ation lic app ntial Foamular sideor RE uide F Ily G am ation F sul In

s ation lic app ntial Foamular sideor RE uide F Ily G am ation F sul In Family GUIDE FOR RESIDENTIAL applications Foamular Where quality and performance make a home The OWENS CORNING FOAMULAR XPS INSULATION FAMILY ALBUM is a critical feature of any home impacting overall comfort

More information

VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD

VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board, vapor retarder and air and moisture barrrier. 1.2 RELATED WORK A. Installation

More information

ROXUL. Insulation. Insulation for an Energy Efficient, Quiet & Safe Home

ROXUL. Insulation. Insulation for an Energy Efficient, Quiet & Safe Home ROXUL Insulation. Insulation for an Energy Efficient, Quiet & Safe Home A global leader Roxul Inc. is part of Rockwool International, the world s largest producer of stone wool insulation a material that

More information

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders

More information

RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES

RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES 1807 Elmwood Avenue, Suite 275 Buffalo, New York 14207 (800) 543-5155 RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES Fiberesin Wall System Provide materials and labor to complete courts

More information

Fire Resistance of Brick Masonry

Fire Resistance of Brick Masonry TECHNICAL NOTES on Brick Construction 1850 Centennial Park Drive, Reston, Virginia 20191 www.gobrick.com 703-620-0010 Fire Resistance of Brick Masonry 16 March 2008 Abstract: This Technical Note presents

More information

Presented by: Jennifer Doyle, P.E., RRC, LEED AP

Presented by: Jennifer Doyle, P.E., RRC, LEED AP Presented by: Jennifer Doyle, P.E., RRC, LEED AP Moisture Gas: Molecules are spread out "Vapor" suspended in air forms a mixture, present everywhere Liquid: Molecules are closer Rain Condensation Pipes

More information

Fiberglas, Exterior Wall Thermal Insulation

Fiberglas, Exterior Wall Thermal Insulation PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.

More information

BXUV.P523 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263

BXUV.P523 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263 Page 1 of 5 Page Bottom BXUV.P523 Fire Resistance Ratings - ANSI/UL 263 Fire Resistance Ratings - ANSI/UL 263 See General Information for Fire Resistance Ratings - ANSI/UL 263 Design No. P523 March 21,

More information

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited** PHRC Webinar Series Tuesday, September 9, 2014 1:00 pm Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited** Presented by: Bryan Heitzmann Credit(s) earned on completion of

More information

GreenGuard Housewrap Installation Guide

GreenGuard Housewrap Installation Guide 000768PACBPHW_Flashing Bro 5/23/03 2:52 PM Page 1 For the most current product information, go to www.green-guard.com. Pactiv Building Products believes the information and recommendations herein to be

More information

Housing Fact Sheets. Insulation Check-Up

Housing Fact Sheets. Insulation Check-Up Insulation Check-Up Housing Fact Sheets Introduction Heating and cooling account for the majority of energy costs in homes throughout the United States. Although current energy prices are relatively low,

More information

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES Scope 1.1.

More information

High Performance Building Systems. Building Science Solutions Extreme Thermal Performance Insect & Mold Resistant

High Performance Building Systems. Building Science Solutions Extreme Thermal Performance Insect & Mold Resistant High Performance Building Systems Building Science Solutions Extreme Thermal Performance Insect & Mold Resistant Cutting Edge Technology SIPS-Structurally Insulated Panels SIPs are high-performance building

More information

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................

More information

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory

More information

EcoTouch Insulation with PureFiber Technology

EcoTouch Insulation with PureFiber Technology PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.

More information

*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.

*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company. Dow Chemical is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will be reported to CES Records for AIA members.

More information

Spray Foam Insulation and Roofing Systems

Spray Foam Insulation and Roofing Systems Spray Foam Insulation and Roofing Systems Accelerate Your Performance SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com Celebrating 40 Years of Foam Quik-Shield brand is owned and operated by SWD

More information

GOOD ROOFING PRACTICE STEEP-SLOPE RE-ROOFING ASPHALT SHINGLE ROOFING 1:3 (4/12) AND GREATER

GOOD ROOFING PRACTICE STEEP-SLOPE RE-ROOFING ASPHALT SHINGLE ROOFING 1:3 (4/12) AND GREATER GOOD ROOFING PRACTICE STEEP-SLOPE RE-ROOFING ASPHALT SHINGLE ROOFING 1:3 (4/12) AND GREATER 1 DECK Revised January 6, 2011 1.1 General a) Application of asphalt shingles directly over rigid insulations

More information

EXPANDED POLYSTYRENE FOR. ResidentialBuilding Applications WWW.FALCONFOAM.COM

EXPANDED POLYSTYRENE FOR. ResidentialBuilding Applications WWW.FALCONFOAM.COM EXPANDED POLYSTYRENE FOR ResidentialBuilding Applications WWW.FALCONFOAM.COM ResidentialBuildi ExpandedPolystyreneIn Falcon Foam leads the residential building industry with products that are environmentally

More information

Styrodur C, Environmentally friendly extruded polystyrene free of CFC, HCFC, and HFC filled with air.

Styrodur C, Environmentally friendly extruded polystyrene free of CFC, HCFC, and HFC filled with air. Styrodur C, Environmentally friendly extruded polystyrene free of CFC, HCFC, and HFC filled with air. Thermal insulation does more than protect the climate Effective thermal insulation with Styrodur C

More information

Study of Poured-In-Place Concrete Wall Performance in Coastal British Columbia

Study of Poured-In-Place Concrete Wall Performance in Coastal British Columbia AGENDA l Study of Poured-In-Place Concrete Wall Performance in Coastal British Columbia l Types of Concrete Walls l Water Penetration Control Strategies l Focus on Poured In Place Concrete Walls CONTEXT

More information

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs The better way to build TM Installation Manual EXTERIOR WALL SIPs July 2015 EXTERIOR WALL SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................

More information

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: 1-800-TEC-WOOD (832-9663)

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: 1-800-TEC-WOOD (832-9663) HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: 1-800-TEC-WOOD (832-9663) Fire-Retardant-Treated Wood Framed Wall Assemblies GENERAL INFORMATION Fire-resistant construction

More information

SECTION THERMOPLASTIC MEMBRANE ROOFING (Changed by Addendum 2)

SECTION THERMOPLASTIC MEMBRANE ROOFING (Changed by Addendum 2) SECTION 07 5419 THERMOPLASTIC MEMBRANE ROOFING (Changed by Addendum 2) PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Rigid roof insulation. 2. (Changed by Addendum 1) Mechanically attached single

More information

DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 21 00 THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 21 00 THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-3758 Reissued 04/2016 This report is subject to renewal 04/2017. DIVISION: 07 00 00 THERMAL

More information

AUTHORIZATION TO MARK

AUTHORIZATION TO MARK AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set

More information

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings

More information

Article. Protecting the Building Envelope from Water Damage. MemBrain Smart Vapor Retarder & Air Barrier Film

Article. Protecting the Building Envelope from Water Damage. MemBrain Smart Vapor Retarder & Air Barrier Film Article Protecting the Building Envelope from Water Damage Vapor Retarders Play a Crucial Role in Moisture Management Whether we like it or not, moisture in the form of water vapor diffusion and humid

More information

) and air spaces (R a

) and air spaces (R a 5.3.3 Thermal Resistance (R-value) Common thermal properties of materials and air spaces are based on steady state tests, which measure the heat that passes from the warm side to the cool side of the test

More information

Tremco Fire Protection Systems Group Technical Bulletin

Tremco Fire Protection Systems Group Technical Bulletin Compartmentalization products and design play a key role in protecting lives and property from fire. Understanding the tools and techniques available for firestopping is of utmost importance to designers,

More information

07 21 19 Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

07 21 19 Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM 07 21 19 STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM 7819 Broadview Road Cleveland, OH 44131 800-522-4522 February, 2011 SPEC NOTE: This guide specification is intended for use when specifying

More information

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the

More information

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS TITLE: STANDARDS FOR NEW ROOFING CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS Responsible Organization: Office of Facilities Planning Instructions: This Manual supersedes

More information

REPORT HOLDER: ATLAS ROOFING CORPORATION 2000 RIVEREDGE PARKWAY, SUITE 800 ATLANTA, GEORGIA EVALUATION SUBJECT:

REPORT HOLDER: ATLAS ROOFING CORPORATION 2000 RIVEREDGE PARKWAY, SUITE 800 ATLANTA, GEORGIA EVALUATION SUBJECT: 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-1375 Reissued 03/2016 This report is subject to renewal 03/2018. DIVISION: 07 00 00 THERMAL

More information

PRECAST CONCRETE PANEL

PRECAST CONCRETE PANEL PANEL COMPOSITE WOOD PANEL SYSTEMS TEAM: RNR MEMBERS : DEISY RAMIREZ HITO RODRIGUEZ JASON SAI HUNG NG PANEL AIR BARRIERS AND The vapor barrier in this assembly is the precast concrete itself. Therefore

More information

Boise Cascade Wood Products L.L.C. Revised August 16, 2016

Boise Cascade Wood Products L.L.C. Revised August 16, 2016 Fire-Rated Assemblies PR-S201 Boise Cascade Wood Products L.L.C. Revised August 16, 2016 Products: BCI and AJS I-Joists, and VERSA-LAM Rimboards Boise Cascade Wood Products L.L.C., 1111 West Jefferson

More information

Atlantic Post and Beam Construction 1245 Hanwell Rd. Fredericton, NB. E3C 1A6 Tel: (506) 450-5445

Atlantic Post and Beam Construction 1245 Hanwell Rd. Fredericton, NB. E3C 1A6  Tel: (506) 450-5445 Atlantic Post and Beam Construction 1245 Hanwell Rd. Fredericton, NB. E3C 1A6 www.atlanticpostandbeam.ca Tel: (506) 450-5445 Prefabricated/Modular Timber frame Home / Cottage: At Atlantic Post and Beam,

More information

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Office and Production 126 New Pace Rd., PO Box 279 Newcomerstown, OH 43832 1-800-446-2188, Fax: 740-498-4184 www.buildwithsips.com CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Table of Contents Description

More information

DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 21 00 THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 21 00 THERMAL INSULATION REPORT HOLDER: ICYNENE, INC. 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-1826 Reissued 02/2016 This report is subject to renewal 02/2018. DIVISION: 07 00 00 THERMAL

More information

Introduction. Required Materials

Introduction. Required Materials C e r t a i n Te e d Air Barrier Installation Instructions for Wood Framing Introduction In addition to performing as an interior vapor retarder, MemBrain may be installed as a continuous, interior air

More information

R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2C Energy & IAQ (2013) Related TEK: 2-5B, 6-1C, 6-4B, 6-11A, 6-12C, 6-12D, 6-12E

R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2C Energy & IAQ (2013) Related TEK: 2-5B, 6-1C, 6-4B, 6-11A, 6-12C, 6-12D, 6-12E An information series from the national authority on concrete masonry technology R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS TEK 6-2C Energy & IAQ (201) INTRODUCTION Single wythe concrete

More information

Sun Windows General Information Sun New Construction Window Installation Instructions

Sun Windows General Information Sun New Construction Window Installation Instructions Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten

More information

Comment Form on Proposed Gut Rehabilitation Alternatives

Comment Form on Proposed Gut Rehabilitation Alternatives Comment Form on Gut Rehabilitation Alternatives Name: Organization: Email: Instructions Submission: Please submit this form to energystarhomes@energystar.gov by October 10 th, 2012 with the subject line

More information

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and

More information

SECTION 07550 - MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.

SECTION 07550 - MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck. SECTION 07550 - PART I GENERAL 1.01 SECTION INCLUDES A. Vapor barrier (base ply); cover board at existing roof deck. B. Roof insulation at new roof deck. C. Modified bitumen membrane. D. Fluid applied

More information

Building Envelope Design COMFORTBOARD IS. Exterior Insulated Sheathing for High-Performance Residential Wall Systems

Building Envelope Design COMFORTBOARD IS. Exterior Insulated Sheathing for High-Performance Residential Wall Systems Building Envelope Design by Roxul Building Envelope Design by ROXUL (BEDR ) COMFORTBOARD IS Exterior Insulated Sheathing for High-Performance Residential Wall Systems The Shore House North Vancouver, BC,

More information

REFLECTIVE INSULATION, RADIANT BARRIERS,

REFLECTIVE INSULATION, RADIANT BARRIERS, REFLECTIVE INSULATION, RADIANT BARRIERS, AND INTERIOR RADIATION CONTROL COATINGS FOR USE IN PRE-ENGINEERED METAL BUILDINGS Technical Bulletin #107 Scope: In both the United States and Canada there is significant

More information

2009 IECC Update. Scope. Content. International Energy Conservation Code

2009 IECC Update. Scope. Content. International Energy Conservation Code 2009 IECC Update International Energy Conservation Code Scope The code applies to both residential and commercial buildings. In the code, the United States is divided into eight climate zones which are

More information

Building Envelope Design. ComfortBoard IS. Exterior Insulated Sheathing for High-Performance Residential Wall Systems

Building Envelope Design. ComfortBoard IS. Exterior Insulated Sheathing for High-Performance Residential Wall Systems Building Envelope Design by Roxul Building Envelope Design by Roxul (BEDR ) ComfortBoard IS Exterior Insulated Sheathing for High-Performance Residential Wall Systems The Shore House North Vancouver, BC,

More information

Asphalt Shingle Application Requirements

Asphalt Shingle Application Requirements Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt

More information

Meeting the Fire Code with Continuous Foam Plastic Insulation

Meeting the Fire Code with Continuous Foam Plastic Insulation Dow Building Solutions Meeting the Fire Code with Continuous Foam Plastic Insulation The 2012 International Building Code (IBC) specifies the fire tests that must be passed if a foam plastic material is

More information

Chapter 5: Air Leakage and Moisture Control

Chapter 5: Air Leakage and Moisture Control Chapter 5: Air Leakage and Moisture Control [502.1.6] Vapor Retarders. A vapor retarder is a material placed to minimize vapor movement through the diffusion process. Types of vapor retarders include:

More information

A. Section Thermal and Moisture Protection. D. Section Operation and Maintenance of Thermal and Moisture Protection.

A. Section Thermal and Moisture Protection. D. Section Operation and Maintenance of Thermal and Moisture Protection. -------------------------------------------------------------------------------------------------------------------------------- Firestall Roof Deck Architectural Specifications CSI Section 07 --------------------------------------------------------------------------------------------------------------------------------

More information

Insulation Requirements vs. Fire Protection Requirements for Basements per IRC-2012

Insulation Requirements vs. Fire Protection Requirements for Basements per IRC-2012 Mark Bartel, P.E., Technical Director International Beams Page 1 of 8 Fire protection requirement of R503.1, IRC-2012 Here are some solutions to meeting the fire protection requirements of IRC-2012 that

More information

Continuous Dow Corning 791 Silicone Weatherproofing Sealant cap along edge of silicone transition strip. Dow Corning Silicone Transition System (STS)

Continuous Dow Corning 791 Silicone Weatherproofing Sealant cap along edge of silicone transition strip. Dow Corning Silicone Transition System (STS) : Drawing Details Details cap along edge of silicone transition strip Silicone Transition System (STS) Fillet bead of at top of flashing lapped on to flashing, over STS and onto field layer layers staggered

More information