Sound insulation solutions

Size: px
Start display at page:

Download "Sound insulation solutions"

Transcription

1 Sound insulation solutions Guide to meeting the Code for Sustainable Homes; Health and Wellbeing

2 Contents Background An introduction to the Code for Sustainable Homes Mandatory ratings How the Code works Weightings, credits and percentage points Health and wellbeing British Gypsum enhanced sound insulating solutions Twin frame steel separating walls Single frame steel separating walls Timber frame separating walls Masonry separating walls Separating floors Front Cover Image: Berkeley Homes, Royal Arsenal, Woolwich Contents Page Images: Courtesy of Taylor Wimpey

3 Background An introduction to the Code for Sustainable Homes The Code for Sustainable Homes (the Code) has been introduced to drive a step-change in sustainable home building practice in England. It is a means of driving continuous improvement, greater innovation and exemplary achievement in sustainable home building. The Code is a standard for key elements of design and construction which affect the sustainability of a new home. It is the single national standard for sustainable homes, used by home designers and builders as a guide to development, and by home-buyers to assist in their choice of home. The Code measures the sustainability of a home against design categories, rating the whole home as a complete package. The sustainability categories included within the Code are: Energy and CO emissions Water Materials Surface water run-off Waste Pollution Health and wellbeing Management Ecology The Code uses a sustainability rating system, indicated by stars, to communicate the overall sustainability performance of a home. A home can achieve a sustainability rating from one star ( ) to six stars ( ) depending on the extent to which it has achieved Code standards. One star is the entry level, above the level of the Building Regulations, and six stars is the highest level, reflecting exemplary development in sustainability terms. Mandatory ratings On the st May 008, a rating against the Code for new build homes in England became mandatory. This mandatory requirement came into effect for all developments where a local authority received a building notice, initial notice or full plans application after the st May. However, this new requirement does not make it mandatory to build a Code home or to have each new home assessed against the Code. It does, however, mean that all buyers of new homes must be given clear information about the sustainability of the new home. A house builder can do this in one of two ways: or They can chose to build a Code home, have that home assessed against the Code and provide the home buyer with a Code certificate stating the star rating the home has achieved They can choose to build a home to current building regulations standards, not to pay for an assessment and instead download a free nil-rated certificate of non-assessment (also referred to as a nil-rating) to provide to the home buyer. In England and Wales Code level is required for all government funded social housing. The Code does not apply in Scotland. bgtechnical.enquiries@bpb.com

4 How the Code works The Code for Sustainable Homes is an environmental assessment rating method for new homes in England that: Identifies a set of issues that are known to impact on the environment Establishes performance measures that: are known to reduce environmental impacts. exceed the requirements of legislation and regulations. - can be objectively assessed, evaluated and delivered in a practical and cost effective way by the construction industry. Identifies environmental issues for which mandatory minimum performance must be achieved in order to gain a Code rating. Background Assesses environmental performance in a two stage process (design stage and post construction) using objective criteria and verification. Records results of the Code assessment on a certificate assigned to the dwelling. Weightings, credits and percentage points The table below shows how weightings are applied across all Code categories of environmental impact to adjust the relative values of credits within different categories. Within each category credits are awarded for achieving specified degrees of performance. The weighting factors show the contribution made by each category to the total performance recognised and rewarded by the Code. The total available contribution is expressed as 00%. The weighting of each category is expressed as a fraction of this, such that the sum of all the category contributions equals 00%. As an example, the credits available for Health and Wellbeing contribute to 4% of the total available performance. Categories of Total credits Weighting factor environmental in each category (% points contribution) impact Energy and CO emissions 9 6.4% Water 6 9.0% Materials 4 7.% Surface water run-off 4.% Waste 7 6.4% Pollution 4.8% Health and wellbeing 4.0% Management 9 0.0% Ecology 9.0% Total % British Gypsum can help home builders achieve Code credits in the categories of energy and CO emissions, materials, waste, pollution and health and wellbeing. This document details how British Gypsum solutions can gain credits for home builders under the health and wellbeing section, when enhanced sound insulating systems are specified. Drywall Academy Tel:

5 Background Health and wellbeing Sustainable homes can also provide us with improved overall wellbeing and quality of life. The health and wellbeing category within the Code for Sustainable Homes encourages higher standards of sound insulation in order to reduce the likelihood of noise complaints from neighbours. One of the most common causes for disputes between neighbours is noise. Environmental Health Officers in England and Wales received nearly 6000 noise complaints per million people from domestic premises in 00/004. This accounts for 75% of all noise complaints received. Credits are awarded for achieving higher standards of sound insulation than those given in the Building Regulations Approved Document E and demonstrating it by either using Pre-Completion Testing or Robust Details. Criteria Credits awarded Where: Airborne sound insulation values are at least db higher Impact sound insulation values are at least db lower credit or Airborne sound insulation values are at least 5dB higher Impact sound insulation values are at least 5dB lower credits or Airborne sound insulation values are at least 8dB higher Impact sound insulation values are at least 8dB lower 4 credits than the performance standards set out in the Building Regulations for England and Wales, Approved Document E. The criteria is demonstrated through either a programme of pre-completion testing based on the normal programme of testing described in the Building Regulations Approved Document E or use of constructions for all relevant building elements that have been assessed and approved by Robust Details Limited and found to achieve the performance standards stated above. All relevant dwellings must be registered with Robust Details Limited prior to construction. Default cases Detached dwellings Attached dwellings where separating walls or floors only occur between non-habitable rooms. 4 credits credits 4 bgtechnical.enquiries@bpb.com

6 British Gypsum enhanced sound insulating solutions British Gypsum provides a range of masonry, timber and steel solutions that have the potential to achieve higher sound insulating performance than the standards set out in Approved Document E. When specifying these elements, as detailed in the following pages, British Gypsum can help home builders achieve credits towards the Code level required. A Code level is awarded on the basis of achieving both a set of mandatory minimum standards and a minimum overall score. Background The number of credits achieved is divided by the total available and multiplied by the category weighting factor to give a percentage points score for the category. The percentage points scores for each category are then summed to arrive at the total percentage points score for the dwelling. The Code level is derived from the total points achieved. The relationship between total percentage points score and Code level is shown below; Code levels Level ( ) Level ( ) Level ( ) Level 4 ( ) Level 5 ( ) Level 6 ( ) Total percentage points score (equal to or greater than) 6 points 48 points 57 points 68 points 84 points 90 points The systems shown on the following pages have the potential to achieve the number of credits stated, equivalent to up to.5 points, provided they are built correctly. For separating wall and floor constructions to be fully effective, care must be taken to correctly detail the junctions between the separating wall or floor and associated elements such as external walls, other separating elements and penetrations or door openings. If junctions are incorrectly detailed then the acoustic performance will be limited and the credit requirements will not be achieved in practice. The number of credits awarded to a dwelling is determined by the lowest performing separating wall or floor, regardless of whether the assessment is based on Pre-Completion Testing, use of Robust Details, or a mixture of both. The dwellings in a group or sub-group that have been tested are awarded credits appropriate to their measured performance. Other dwellings in the group, or sub-group, that were not tested are awarded the same number of credits as the lowest performing separating walls or floors in the same group or sub-group that was tested. Robust Details Limited publish and update a table of constructions that meet the Code criteria. However, it should be noted that not all Robust Details will necessarily achieve the performance levels required for Code credits. The award of credits to Robust Detail constructions is subject to review and revision, and therefore specifiers are advised to review the information at Developers using Robust Details will not have to conduct additional Pre-Completion Testing to achieve Code credits. Drywall Academy Tel:

7 Twin frame steel separating walls Twin frame steel separating walls EN BS Table - Twin frame steel separating walls to satisfy the requirements of BS EN 64-: 999 and BS 476: Part : 987 GypWall QUIET IWL Two layers of board fixed to the outside faces of two Gypframe 48 I 50 stud I stud frameworks with studs at 600mm centres. 50mm Isover APR 00 in the cavity (cavity width 40mm). Linings as in table. 4 GypWall QUIET IWL Two layers of board fixed to the outside faces of two Gypframe 60 I 50 stud I stud frameworks with studs at 600mm centres. 00mm Isover APR 00 in the cavity (cavity width 90mm). Linings as in table. L I F E T I M E SPECSURE S Y S T E M W A R R A N T Y GypWall QUIET Two layers of board fixed to the outside faces of two Gypframe 48 S 50 C stud frameworks studs at braced at max 00mm centres. 75mm Isover Acoustic High Performance Slabs in the cavity (cavity width 90mm). Linings as in table. GypWall QUIET Two layers of board fixed to the outside faces of two Gypframe 48 S 50 C stud frameworks braced at max 00mm centres. 00mm Isover APR 00 in the cavity (cavity width 90mm). Linings as in table. -Detail Partition Board Lining Stud Max height Insulation Airborne sound Potential Duty System thickness type thickness mm insulation code rating reference mm mm mm EN BS mm R w (R w + Ctr) credits db 90 minutes fire resistance EN BS 4 00 SoundBloc x (58) Severe A SoundBloc x (57) Severe A60 00 SoundBloc x (58) Severe A60 50 SoundBloc x (6) Severe A bgtechnical.enquiries@bpb.com

8 Single frame steel separating walls EN BS Table - Single frame steel separating walls to satisfy the requirements of BS EN 64-: 999 and BS 476: Part : 987 GypWall CLASSIC Two layers of board fixed to Gypframe 46 AS 50 Acoustuds at 600mm centres, 50mm Isover APR 00 (00mm + 50mm or x 75mm) In the cavity. Linings as in table. L I F E T I M E SPECSURE S Y S T E M W A R R A N T Y Single frame steel separating walls GypWall QUIET SF Two layers of boards fixed to Gypframe C Studs at 600mm centres with Gypframe RB Resilient Bar at 600mm centres to one side. 50mm Isover APR 00 in the cavity. Linings as in table. GypWall QUIET SF Two layers of boards fixed to Gypframe C Studs at 600mm centres with Gypframe RB Resilient Bar at 600mm centres to both sides. 50mm Isover APR 00 in the cavity. Linings as in table. Detail Partition Board Lining Stud Max height Insulation Airborne sound Potential Duty System thickness type thickness mm insulation code rating reference mm mm mm EN BS mm R w (R w + Ctr) credits db 90 minutes fire resistance EN BS 08 SoundBloc x (57) Severe A06A55 4 SoundBloc x (57) Severe A SoundBloc x (57) Severe A60 40 SoundBloc x (59) Severe A609 Drywall Academy Tel:

9 Timber frame separating walls Timber frame separating walls BS Table - Timber frame separating walls to satisfy the requirements of BS 476: Part : 987 (Loadbearing) Robust Detail E-WT- Two separate timber frames spaced a minimum of 50mm apart. Two layers of board each side. 65mm Isover APR 00 or 90mm Isover Frame Batt between the studs in each timber frame. Linings as in table. Robust Detail E-WT- Two separate timber frames, each sheathed with a 9mm minimum thick board, spaced a minimum of 50mm apart. Two layers of board each side. 65mm Isover APR 00 or 90mm Isover Frame Batt between the studs in each timber frame. Linings as in table. Detail Partition Board Lining Airborne Potential thickness type thickness sound code mm mm insulation credits 60 minutes fire resistance BS 00 SoundBloc x 5 Robust Detail E-WT- 00 Plank and Robust Detail E-WT- WallBoard 00 SoundBloc x 5 Robust Detail E-WT- 00 Plank and 9 x.5 Robust Detail E-WT- WallBoard NB The award of credits to Robust Detail constructions is subject to review and revision, and therefore specifiers are advised to regularly review the information at bgtechnical.enquiries@bpb.com

10 Masonry separating walls Table 4 - Masonry separating walls Robust Detail E-WM-,, 4 OR 6 Robust Detail E-WM- Block cavity wall comprising 00mm blocks with 75mm cavity. Block cavity wall comprising 00mm blocks with 00mm Block and lining options as in table. cavity. Block and lining options as in table. Masonry separating walls 4 Robust Detail E-WM-8 Block cavity wall comprising 0mm blocks with 75mm cavity. 5mm Isover RD5 in the cavity. Block and lining options as in table. Robust Detail E-WM-4 Block cavity wall comprising 0mm blocks with 00mm cavity. 5mm Isover RD5 in the cavity. Block and lining options as in table. Detail Wall Block type Parge coat Lining Lining Airborne Potential thickness kg/m thickness sound code mm mm insulation credits Aggregate N/A Thistle Robust Detail E-WM Plaster 6 Aggregate Gyproc WallBoard.5 Robust Detail E-WM SoundCoat 6 Aggregate Gyproc WallBoard.5 Robust Detail E-WM SoundCoat 6 Aircrete Sand/Cement WallBoard.5 Robust Detail E-WM Aggregate N/A WallBoard TEN.5 Robust Detail E-WM Aggregate N/A SoundBloc.5 Robust Detail E-WM Aggregate N/A WallBoard 5 Robust Detail E-WM Aggregate Gyproc WallBoard.5 Robust Detail E-WM SoundCoat 45 Aggregate N/A WallBoard TEN. 5 Robust Detail E-WM Aggregate N/A SoundBloc. 5 Robust Detail E-WM-4 NB The award of credits to Robust Detail constructions is subject to review and revision, and therefore specifiers are advised to regularly review the information at Drywall Academy Tel:

11 Separating floors Separating floors Table 5 - Separating Floors L I F E T I M E SPECSURE S Y S T E M W A R R A N T Y Robust Detail E-FT- A sub-deck of 5mm OSB and an RD approved floating floor system. Minimum 40mm depth engineered timber I-joist. 00mm Isover APR 00 in the joist cavity. Gypframe RB Resilient Bar ceiling. Ceiling linings as in table. Robust Detail E-FS- GypFloor SB floating floor system incorporating either 50mm or 70mm Gypframe Steel Battens. Minimum 80mm concrete cover at shallowest point, minimum 0mm at deepest point of metal deck In-situ concrete slab, minimum density of 00kg/m, supported on a profiled metal deck CasoLine MF or GypLyner UNIVERSAL ceiling. Ceiling linings as in table. Robust Detail E-FS- A sub deck of mm wood based board and an RD approved floating floor system. 5mm UltraBEAM metal joists. 00mm Isover APR 00 in the joist cavity. Gypframe RB Resilient Bar ceiling. Ceiling linings as in table. Detail Board type Lining Airborne and impact Potential thickness sound insulation code mm credits Plank and SoundBloc Robust Detail E-FT- Plank and WallBoard TEN Robust Detail E-FT- SoundBloc x 5 Robust Detail E-FT- WallBoard TEN.5 Robust Detail E-FS- Plank and SoundBloc Robust Detail E-FS- Plank and WallBoard TEN Robust Detail E-FS- SoundBloc x 5 Robust Detail E-FS- NB The award of credits to Robust Detail constructions is subject to review and revision, and therefore specifiers are advised to regularly review the information at bgtechnical.enquiries@bpb.com

12 Separating floors Table 6 - Separating Floors L I F E T I M E SPECSURE S Y S T E M W A R R A N T Y Separating floors Robust Detail E-FC-0 mm Thermal Economics IsoRubber floor covering Minimum 75mm depth in-situ concrete floor slab, with minimum density 400kg/m. CasoLine MF or GypLyner UNIVERSAL ceiling set to a minimum of 50mm cavity depth. Ceiling linings as in table. GypFloor SB 8mm chipboard and layer of Gyproc Plank on Gypframe 70 S 65 Steel Battens. 5mm Isover APR 00 in batten cavity. 5mm (min) screed applied directly to precast concrete planks. CasoLine MF ceiling suspended from concrete planks to create a 40mm cavity. Ceiling linings as in table. Detail Board type Lining Airborne and impact sound Potential System thickness insulation code reference R w (R w + Ctr) L nw credits db WallBoard TEN.5 Robust Detail E-FC-0 SoundBloc.5 Robust Detail E-FC-0 SoundBloc x.5 7 (6) 4 C0006 NB The award of credits to Robust Detail constructions is subject to review and revision, and therefore specifiers are advised to regularly review the information at Drywall Academy Tel:

13 Gyproc, Thistle, Gypframe, Glasroc and Arteco are all registered trade names of BPB United Kingdom Limited. Isover is a registered trade name of Saint-Gobain. Proprietor: BPB United Kingdom Limited registered in England 7496, registered office Saint-Gobain House, Binley Business Park, Coventry CV TT British Gypsum reserves the right to revise product specifications without notice. The information in this document was correct to the best of our knowledge at the time of publication. It is the user s responsibility to ensure that it remains current prior to use. The information in this document is for guidance only and should not be read in isolation. Users should read and familiarise themselves with all the information contained in this document and ensure that they are fully conversant with the products and systems being used, before subsequent specification or installation. For a comprehensive and up-to-date library of information visit the British Gypsum website at: Technical enquiries British Gypsum Drywall Academy East Leake Loughborough Leicestershire LE 6JT Telephone: Fax: bgtechnical.enquiries@bpb.com Training enquiries: FM 558 British Gypsum March CSH-0 A Saint-Gobain Company

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available. APR 1200 Acoustic Partition Roll CI/Sfb Ref: APR002 Glass mineral wool roll designed to provide high levels of sound insulation in walls and floors to meet Part E (England & Wales) and Section 5 (Scotland)

More information

CasoLine QUICK-LOCK grid systems

CasoLine QUICK-LOCK grid systems CasoLine QUICK-LOCK grid systems CasoLine QUICK-LOCK T grid 90-0mm up to 000-00mm Tile edge details swg CasoLine QUICK-LOCK T/8 000mm CasoLine QUICK-LOCK T/8 600mm A Gyprex / Gyptone CasoLine QUICK-LOCK

More information

Glasroc F multiboard Five high performances in one board

Glasroc F multiboard Five high performances in one board Glasroc F multiboard Five high performances in one board Glasroc F multiboard is non-combustible and depending on which of the three thickness you use can give you up to 120 minutes fire resistance. Great

More information

Rockwool Flexi Insulation Application Guide

Rockwool Flexi Insulation Application Guide Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed

More information

Guide to domestic building renovation. Telephone: 0844 800 1991 Fax: 0844 561 8816 Email: bgtechnical.enquiries@bpb.com

Guide to domestic building renovation. Telephone: 0844 800 1991 Fax: 0844 561 8816 Email: bgtechnical.enquiries@bpb.com BRITISH GYPSUM A BUSINESS SUPERBRAND SINCE 2008 Gyproc, Thistle, Gypframe and Glasroc are all registered trade names of BPB United Kingdom Limited. Isover is a registered trade name of Saint-Gobain. Proprietor:

More information

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with Section Separating Floors Timber frame floor with I-Beams Product: Earthwool Acoustic Roll and Floorfoam Easy Edge Strip Timber frame floor with solid timber joists Product: Earthwool Acoustic Roll and

More information

FireWall. High performance fireresistant. FireWall. www.british-gypsum.com

FireWall. High performance fireresistant. FireWall. www.british-gypsum.com FireWall FireWall High performance fireresistant wall system FireWall is a non-loadbearing wall which provides up to 240 minutes fire resistance. It is used in certain ground floor basement situations

More information

C05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction

C05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction C05. S03. P02 P08 Including C05. S01. P02 Specialist partitions introduction C05 Specialist partitions Introduction Specialist partitions This section details specialist lightweight systems where high-security,

More information

C09. S02. P02 P14 CasoLine mf. Including C09. S01. P02 P08 Sound absorbing solutions introduction

C09. S02. P02 P14 CasoLine mf. Including C09. S01. P02 P08 Sound absorbing solutions introduction C09. S0. P0 P Including C09. S0. P0 P08 Sound absorbing solutions introduction C09 Sound absorbing solutions Introduction Sound absorbing solutions This section details sound absorbing solutions which

More information

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory

More information

British Gypsum Guide to Timber Frame Construction. March 1998

British Gypsum Guide to Timber Frame Construction. March 1998 British Gypsum Guide to Timber Frame Construction March 1998 Timber frame construction has a centuries long tradition in the UK, however, over the last 80 years it has continuously evolved to meet the

More information

Finishing guide. For Thistle plaster and Gyproc plasterboard. Telephone: 08705 456123 Fax: 08705 456356 Email: bgtechnical.enquiries@bpb.

Finishing guide. For Thistle plaster and Gyproc plasterboard. Telephone: 08705 456123 Fax: 08705 456356 Email: bgtechnical.enquiries@bpb. BUSINESS SUPERBRAND SINCE 008 Gyproc, Thistle, Gypframe and Glasroc are all registered trade names of BPB United Kingdom Limited. Isover is a registered trade name of Saint-Gobain. Proprietor: BPB United

More information

Manual lifting and handling

Manual lifting and handling Manual lifting and handling When installing British Gypsum products and systems care should be taken to ensure that appropriate methods of handling and lifting are adopted. The following guidance details

More information

ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION

ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 E1 E2 E3 E4 E Protection against sound from other parts of the building and adjoining buildings Protection against

More information

The White Book Refurbishment Guide Effective ways to repair, maintain and improve buildings.

The White Book Refurbishment Guide Effective ways to repair, maintain and improve buildings. The White Book Refurbishment Guide Effective ways to repair, maintain and improve buildings. Welcome to the first edition of The White Book Refurbishment Guide. Within this guide we have compiled an overview

More information

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS NOISE TECHNICAL FACT SHEET FACT SHEET 5 SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS The sound insulation of exterior walls and roof-ceiling systems refers to their ability to reduce external

More information

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES CERTIFICATE OF APPROVAL No CF 5055 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of 1 st Industrial Area,

More information

Lightweight Partition Design for Residential and Commercial Buildings

Lightweight Partition Design for Residential and Commercial Buildings Lightweight Partition Design for Residential and Commercial Buildings Stanley D. Gatland II, CertainTeed Corporation, Valley Forge, Pennsylvania Guidelines are presented for the design and proper installation

More information

Energy Company Obligation (ECO): Technical Monitoring Questions

Energy Company Obligation (ECO): Technical Monitoring Questions Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified

More information

The Pocket Guide To Insulation August 2013

The Pocket Guide To Insulation August 2013 The Pocket Guide To Insulation August 2013 Introduction Knauf Insulation is the UK s leading manufacturer of insulation products, including: Earthwool glass and rock mineral wool Polyfoam ECO extruded

More information

The FIRE BOOK. Passive fire protection solutions

The FIRE BOOK. Passive fire protection solutions The FIRE BOOK Passive fire protection solutions The importance of providing effective fire protection to buildings cannot be over-emphasised. The consequences of a fire occurring in a building, without

More information

How To Certify The Scottsdale Construction System

How To Certify The Scottsdale Construction System BRE CERTIFICATION LIMITED PRODUCT SCOTTSDALE CONSTRUCTION SYSTEM CERTIFICATE NUMBER 129/07 DATE OF ISSUE December 2007 SUPPLIED BY Scottsdale Construction System Ltd SUMMARY The Scottsdale Construction

More information

Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining Section Timber Frame Walls Single layer between studs Product: Earthwool FrameTherm Rolls and Slabs Tf01 Single layer between studs with service void Product: Earthwool FrameTherm Rolls and Slabs Tf02

More information

Partitioning & Ceiling Product Information

Partitioning & Ceiling Product Information Partitioning & Ceiling Product Information tel + 44 (0) 1384 412448 fax + 44 (0) 1384 4494 email enquiries@drywallsteelsections.co.uk web www.drywallsteelsections.co.uk tel + 44 (0) 1384 412448 fax + 44

More information

PB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection

PB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection PB301 July 2009 Lightweight Building Solutions Bushfire Protection www.boral.com.au/bushfireprotection Attached or adjacent within 6m roofed structures such as garages, carports, verandas and the like,

More information

Module 3.7. Thermal bridging

Module 3.7. Thermal bridging Module 3.7 Thermal bridging Learning Outcomes On successful completion of this module learners will be able to - Describe construction details which influence thermal bridging. 2 Introduction to thermal

More information

Composite Panel Firewall Systems

Composite Panel Firewall Systems Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.

More information

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability 1/9/13 By Brett T. Fagan, P.E. Presented by Marie Horan, P.E. Building Diagnostics, Inc. Building Diagnostics Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

More information

Controlling the Transmission of Impact Sound through Floors

Controlling the Transmission of Impact Sound through Floors Construction Technology Update No. 35 Controlling the Transmission of Impact Sound through Floors by A.C.C. Warnock This Update presents guidelines for controlling the transmission of impact sound through

More information

Acoustics factsheet Requirements for new homes and how NHBC can help

Acoustics factsheet Requirements for new homes and how NHBC can help Acoustics factsheet Requirements for new homes and how NHBC can help New homes are built to high standards; however, acoustics and noise control are important factors requiring careful consideration during

More information

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors Roxul Safe n Sound Sound Control and Fire Safety From One Batt Insulation Roxul

More information

Structural fire design Eurocode 5-1.2 Timber structures

Structural fire design Eurocode 5-1.2 Timber structures Background and Applications Brussels, 18-20 February 2008 Dissemination of information workshop 1 Structural fire design Eurocode 5-1.2 Timber structures Jochen Fornather Austrian Standards Institute jochen.fornather@on-norm.at

More information

Rev 1-12.2013. Code of Practice. SIP Technology. www.uksips.org

Rev 1-12.2013. Code of Practice. SIP Technology. www.uksips.org Rev 1-12.2013 Code of Practice SIP Technology www.uksips.org What are Structural Insulated Panels (SIPS)? SIPS are prefabricated, high performance, lightweight, building panels that can be used in floors,

More information

Best Practice in Best Pra ctice in teel constr uction - onstr industrial B uildings esidential Buildings 01 Introduction 02 Key Design Factors

Best Practice in Best Pra ctice in teel constr uction - onstr industrial B uildings esidential Buildings 01 Introduction 02 Key Design Factors Best Practice in Steel Construction - Industrial Residential Buildings Contents The Steel Construction Institute (SCI) develops and promotes the effective use of steel in construction. It is an independent,

More information

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap Tile Backing Will not deteriorate in water Easy to score and snap Resistant to mould and mildew Knauf Aquapanel Interior Cement board for wet areas Knauf Aquapanel Interior Cement Board Drywall for Wet

More information

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors. Fire & Soundproofing Insulation Roxul SAFE N SOUND Fire and Soundproofing Insulation for Interior Partition Walls and Floors. Roxul SAFE N SOUND Sound control and fire safety from one batt Insulation.

More information

Ecojoist. Practical benefits of Ecojoist. www.eleco.com/gang-nail

Ecojoist. Practical benefits of Ecojoist. www.eleco.com/gang-nail Ecojoist Practical benefits of Ecojoist. www.eleco.com/gang-nail Gang-Nail Systems, an Eleco plc company, offer integrated solutions f the timber engineering industry which assist in reducing design, production

More information

Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37

Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37 Contents Pages Full fill cavity walls 2-13 Partial fill cavity walls 14-25 Solid externally insulated walls 26-37 Appendix (BRE confirmation of Ψ and y-values) 38-40 Page 1 of 40 APA Construction Details

More information

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,

More information

Approved Document Q: Security

Approved Document Q: Security Approved Document Q: Security Requirement Q1 Unauthorised access Consultation draft September 2014 1 The approved documents What is an approved document? The Secretary of State has approved a series of

More information

H-Stud Area Separation Wall System

H-Stud Area Separation Wall System 12 TH EDITION 09 21 16.33/NGC H-Stud Area Separation Wall System 09 21 16.33 139 H-STUD AREA SEPARATION WALL SYSTEM The fire-protection of gypsum-based Area Separation Walls is demonstrated in dramatic

More information

Metsä Wood. Jussi Björman. R&D Engineer

Metsä Wood. Jussi Björman. R&D Engineer Metsä Wood Jussi Björman R&D Engineer METSÄ GROUP Net sales, total 5,0 EUR billion Personnel, total 9 600 METSÄLIITTO COOPERATIVE Group s parent company Owned by 116,000 Finnish forest owners METSÄ FOREST

More information

Sports Buildings: budget costs for the Flood Relief Fund

Sports Buildings: budget costs for the Flood Relief Fund Sports Buildings: budget costs for the Flood Relief Fund The list below provides typical costs for flood insurance works, typically required by sports clubs or facilities. The list is not exhaustive but

More information

REPAIR AND RENEW GRANT Guidelines and application form

REPAIR AND RENEW GRANT Guidelines and application form REPAIR AND RENEW GRANT Guidelines and application form If your home or business has been flooded between 1 December 2013 and 31 March 2014, you may be eligible for help under the Repair and Renew Grant.

More information

CertainTeed. Shaftliner For A rea Separation Firewalls

CertainTeed. Shaftliner For A rea Separation Firewalls CertainTeed Shaftliner For A rea Separation Firewalls M2Tech Shaftliner Type X for Area Separation M2Tech Shaftliner is a specially formulated product for applications where enhanced mold resistance is

More information

Acoustic performance of dwellings and specifics for lightweight constructions Professor Eddy Gerretsen

Acoustic performance of dwellings and specifics for lightweight constructions Professor Eddy Gerretsen Acoustic performance of dwellings and specifics for lightweight constructions Professor Eddy Gerretsen Content Introduction Performance quantities Construction principles What performance is required Does

More information

Building Regulations for the Conservation of Fuel and Power

Building Regulations for the Conservation of Fuel and Power Insulation CI/SfB Rn7 M2 First Issue April 2014 Building Regulations for the Conservation of Fuel and Power ENGLAND EXISTING DWELLINGS 2013 EDITION Low Energy Low Carbon Buildings Contents Page Introduction

More information

The Kingspan Insulation Price List 1 st January 2013

The Kingspan Insulation Price List 1 st January 2013 Insulation The Kingspan Insulation Price List 1 st January 2013 FOR BUILDING FABRIC INSULATION, CAVITY CLOSERS AND MEMBRANES Visit our website: www.kingspaninsulation.co.uk Low Energy - Low Carbon Buildings

More information

FIRE PERFORMANCE OF STRUCTURAL INSULATED PANEL SYSTEMS

FIRE PERFORMANCE OF STRUCTURAL INSULATED PANEL SYSTEMS INFORMATION PAPER IP 21/10 FIRE PERFORMANCE OF STRUCTURAL INSULATED PANEL SYSTEMS Tom Lennon and Danny Hopkin The use of Structural Insulated Panel (SIP) systems in construction in the UK has increased

More information

Report Number BTC 17755F

Report Number BTC 17755F Leics. LE NP Tel () 4 Fax () 4 Email btc.testing@saintgobain.com Report Number BTC 77F A FIRE RESISTANCE TEST ON A LOADBEARING TIMBER JOIST FLOOR INCORPORATING 4mm x 7mm x 47mm SOLID JOISTS PROTECTED BY

More information

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01. Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice

More information

We care about. Environmentally-Friendly Building Products from Renewable Resources. natural building products. Product range overview

We care about. Environmentally-Friendly Building Products from Renewable Resources. natural building products. Product range overview http://upload.wikimedia.org/wikipedia/commons/a/ae/flag_of_the_united_kingdom.svg.0.0 :8 Seite von Environmentally-Friendly Building Products from Renewable Resources Product range overview We care about

More information

Conventions for U-value calculations

Conventions for U-value calculations Conventions for U-value calculations 2006 edition Brian Anderson BRE Scotland BRE is committed to providing impartial and authoritative information on all aspects of the built environment for clients,

More information

Underwriters Laboratories Testing Information

Underwriters Laboratories Testing Information Underwriters Laboratories Testing Information R-8078 Underwriters Laboratories Inc. R-13173 Classified Spray Fiber Surface burning characteristics applied to inorganic reinforced cement board with a maximum

More information

Timber Frame Construction

Timber Frame Construction Timber Frame Construction Introduction Design and Detailing What is timber? Failure modes History of timber frame construction Forms of timber frame construction Live and dead loads Wind loads Roof construction

More information

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: 1-800-TEC-WOOD (832-9663)

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: 1-800-TEC-WOOD (832-9663) HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: 1-800-TEC-WOOD (832-9663) Fire-Retardant-Treated Wood Framed Wall Assemblies GENERAL INFORMATION Fire-resistant construction

More information

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details D Installation Details D1 General D2 Walls D3 Ceilings D4 Reference D Installation Details D Contents D1 General Installation and Fastening Sequence for Steel Studs D1.1 Fastener Selection D1.3 D2 Walls

More information

Fire Resistance of Brick Masonry

Fire Resistance of Brick Masonry TECHNICAL NOTES on Brick Construction 1850 Centennial Park Drive, Reston, Virginia 20191 www.gobrick.com 703-620-0010 Fire Resistance of Brick Masonry 16 March 2008 Abstract: This Technical Note presents

More information

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS

More information

Mineral fibreglass insulation

Mineral fibreglass insulation Isover MULTIMAX 30 Specification code: MW - EN 13162 - T5 - MU1 - WS - WL(P) - AF r 5 TeChNICaL SPeCIFICaTION Insulating slabs made of Isover fibreglass wool. The production method is based on the fibering

More information

PRESTRESSED CONCRETE FLOORING BEAMS

PRESTRESSED CONCRETE FLOORING BEAMS PRESTRESSED CONCRETE FLOORING BEAMS TRIED & TRUSTED Introduction Established in 2001 TT Concrete Products Limited has become a prominent manufacturer of prestressed concrete flooring beams throughout the

More information

KINGSPAN INSULATION KINGSPAN KOOLTHERM K12 FRAMING BOARD INSULATION

KINGSPAN INSULATION KINGSPAN KOOLTHERM K12 FRAMING BOARD INSULATION Kingspan Insulation Limited Pembridge Leominster Herefordshire HR6 9LA Tel: 01544 388601 Fax: 01544 388888 e-mail: general.enquiries@kil.kingspan.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

European Organisation for Technical Approvals

European Organisation for Technical Approvals Warrington Certification Limited, Holmesfield Road, Warrington, WA1 2DS Tel. +44 (0) 1925-646777 Fax +44 (0) 1925-646667 Member of EOTA Authorised and notified according to Article 10 of the Council Directive

More information

Gypsum Board Systems Manual

Gypsum Board Systems Manual CertainTeed Gypsum Board Systems Manual Fire Resistance and Sound Control Design Manual Division 09 GYPSUM BOARD SYSTEMS MANUAL TABLE OF CONTENTS Introduction General Fire Resistance...1 Sound Control...3

More information

GYPSUM AREA SEPARATION FIREWALLS GA-620-2011

GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GA-620-2011 Copyright 2011 Gypsum Association All rights reserved. Printed in U.S.A. Characteristics, properties, or performance of materials or systems herein

More information

HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER 2015. May 2015

HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER 2015. May 2015 HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER 2015 May 2015 MAYOR OF LONDON Housing Standards: Transition Policy Statement. On 25 March 2015 through a written ministerial statement,

More information

Hanson Building Products. precast basement solutions

Hanson Building Products. precast basement solutions Hanson Building Products precast basement solutions Hanson Building Products Basement Systems Add an extra dimension and combine the inherent flexible, structural and waterproof properties of concrete

More information

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed

More information

DEFAULT HEAT LOSS COEFFICIENTS

DEFAULT HEAT LOSS COEFFICIENTS DEFAULT HEAT LOSS COEFFICIENTS SECTION A101 GENERAL REQUIREMENTS A101.1 Scope. The following defaults shall apply to Chapter 4 of both the (RE) and (CE) sections of the IECC. This chapter includes tables

More information

SmartPly OSB3 SMARTPLY

SmartPly OSB3 SMARTPLY SMARTPLY SmartPly OSB3 SmartPly OSB3 is a highly engineered, moisture resistant load-bearing panel designed for use in humid conditions and is therefore ideal for many structural and non-structural applications

More information

Building Condition Assessment: 109-111 North Howard Street Baltimore, Maryland

Building Condition Assessment: 109-111 North Howard Street Baltimore, Maryland KPA The Joint Venture of EBA Engineering, Inc. and Kennedy Porter & Associates, Inc. 4813 Seton Drive, Baltimore, MD 21215 Phone: (410-358-7171) Fax: (410)358-7213 Building Condition Assessment: Baltimore,

More information

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST 0 RIVERSIDE DRIVE, OTTAWA, ON A0.0 COVER SHEET / DRAWING LIST A0. LEGEND AND GENERAL NOTES A0. GENERAL NOTES A0. GENERAL NOTES A0. TYPICAL WASHROOM WALL/SINK SECTION A0. DETAIL - CONTROL JOINT A0. DETAIL

More information

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors Improving the flood resistance of your home Advice sheet 6: Flood-resilient This sheet provides guidance on identifying different types of floor, assessing the routes floodwater may enter, and describes

More information

VIPAC ENGINEERS & SCIENTISTS

VIPAC ENGINEERS & SCIENTISTS VIPAC ENGINEERS & SCIENTISTS Vipac Engineers & Scientists Limited A.B.N. 33 005 453 627 The Victorian Technology Centre Private Bag 16, Port Melbourne, VIC, 3207, AUSTRALIA Telephone +61 3 9647 9700, Facsimile

More information

SIP (STRUCTURAL INSULATED PANEL)

SIP (STRUCTURAL INSULATED PANEL) SIP (STRUCTURAL INSULATED PANEL) KINGSPAN TEK ACORN SIP ABSTRACT BUILDING SERVICES Ltd Kingspan TEK is the manufacturer and supplier of the panels and components. Acorn SIP are the Architects who individually

More information

Heating Load Calculation

Heating Load Calculation Heating Load Calculation ME 425 Air Conditioning System Design Keith E. Elder, P.E. Heating Load Calculation The heating load calculation begins with the determination of heat loss through a variety of

More information

Guidelines for Earthquake Bracing of Residential Water Heaters

Guidelines for Earthquake Bracing of Residential Water Heaters Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)

More information

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01 Section Built-up Metal Roofs Rail and bracket system Product: Earthwool FactoryClad range Bu01 Standing seam system Product: Earthwool FactoryClad range and Earthwool Universal Slab Bu02 Built-up Metal

More information

Fire Protective Options for I-Joist Floor Systems CONSTRUCTION GUIDE

Fire Protective Options for I-Joist Floor Systems CONSTRUCTION GUIDE Fire Protective Options for I-Joist Floor Systems CONSTRUCTION GUIDE Wood: The Natural Choice Engineered wood products are among the most beautiful and environmentally friendly building materials. In manufacture,

More information

MONTHLY PROJECT CONSTRUCTION PROGRESS REPORT #5

MONTHLY PROJECT CONSTRUCTION PROGRESS REPORT #5 Rendering Provided by McKissick Associates MONTHLY PROJECT CONSTRUCTION PROGRESS REPORT #5 Additions and Alterations to Williamsport Area Middle School Williamsport Area School District 17 July 2012 Geo-Thermal

More information

FIRE-RESISTANCE RATINGS WITH STEEL JOISTS

FIRE-RESISTANCE RATINGS WITH STEEL JOISTS FIRE-RESISTANCE RATINGS WITH STEEL JOISTS The Underwriters Laboratories (U.L.) Fire Resistance Directory lists hundreds of assemblies their fire resistance ratings. The Specifying Professional can choose

More information

ROUND ROBIN ON UNCERTAINTY IN SOUND INSULATION MEASUREMENTS.

ROUND ROBIN ON UNCERTAINTY IN SOUND INSULATION MEASUREMENTS. ROUND ROBIN ON UNCERTAINTY IN SOUND INSULATION MEASUREMENTS. I C Critchley MIOA, MInstSCE, P R Dunbavin MSc, FIOA, MIOSH, MSEE, MInstSCE, R Lawrence PhD CPhys MinstP HonFIOA MInstSCE, D J McNeill BSc CEng

More information

Wood-frame Construction, Fire Resistance and Sound Transmission

Wood-frame Construction, Fire Resistance and Sound Transmission Fire Resistance and Sound Transmission For many years, wood-frame construction has been providing Canadians with high-quality, affordable housing. This goes from town houses to multi-storey apartment buildings,

More information

Fire safety in timber buildings

Fire safety in timber buildings Fire safety in timber buildings Introduction Fire spread in buildings is a risk to life safety for which the Building Regulations (for England and Wales 1,2, Scotland 3 and Northern Ireland 4 ) aims to

More information

Building Construction. Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two

Building Construction. Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two Factors governing type selection Economics not necessarily the one that requires the least structural

More information

Squash Court Design general points

Squash Court Design general points Squash Court Design general points Contents: Contents:... 1 1. Squash Court Dimensions... 2 2. CourtTech Walls... 3 3. Dimensional requirements for courts with CourtTech Walls... 3 4. Loading of CT System

More information

Low Carbon Domestic Refurbishment

Low Carbon Domestic Refurbishment www.breeam.com Briefing Paper Low Carbon Domestic Refurbishment Kiruthiga Balson, Gavin Summerson and Steven Stenlund 2 BRE Global Ltd 2014 Permission is granted for this report to be distributed only

More information

CERTIFICATE OF COMPLIANCE Prescriptive Residential Re-roof Project Name:

CERTIFICATE OF COMPLIANCE Prescriptive Residential Re-roof Project Name: STATE OF CALIFORNIA RESIDENTIAL ALTERATIONS - RE-ROOF CERTIFICATE OF COMPLIANCE Prescriptive Residential Re-roof Project Name: CALIFORNIA ENERGY COMMISSION CF-1R-ALT-01-E (Page 1 of 2) Date Prepared: A.

More information

Cover: Houghton Estate, luxury residential estate This page: Protea Hotel, Umhlanga Ridge

Cover: Houghton Estate, luxury residential estate This page: Protea Hotel, Umhlanga Ridge For Walls 1 Cover: Houghton Estate, luxury residential estate This page: Protea Hotel, Umhlanga Ridge Mass per m 2 CTN BPN Overview Description Gyproc RhinoBoard is manufactured according to the ISO 9001

More information

Mark Cramer Inspection Services, Inc.

Mark Cramer Inspection Services, Inc. Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction

More information

Put us to the test. Construction testing and building investigations services from BRE. www.bre.co.uk

Put us to the test. Construction testing and building investigations services from BRE. www.bre.co.uk Put us to the test Construction testing and building investigations services from BRE www.bre.co.uk Backed by an extraordinary range of facilities BRE prides itself on being able to answer virtually any

More information

The right solutions. However, it is inevitable that with the introduction of any new construction system the question arises How does it compare?

The right solutions. However, it is inevitable that with the introduction of any new construction system the question arises How does it compare? Value assessment. The right solutions. We Believe We believe that Porotherm offers both short and long term value to all involved in the building process - from bricklayer to client and everyone in between.

More information

Seattle Public Schools Building Excellence IV Projects Under Construction

Seattle Public Schools Building Excellence IV Projects Under Construction Seattle Public Schools Building Excellence IV Projects Under Construction Project Slide Number Arbor Heights Elementary School 2 Cascadia Elementary School & Robert Eagle Staff Middle School 13 Genesee

More information

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas Powerpanel H 2 O is a cement based board from FERMACELL. Board Characteristics Board Thickness 12.5 mm Board Sizes 1000 x 1200 mm 50 sheets/pallet

More information

Fire and Acoustic. Design Manual. October 2010 / New Zealand

Fire and Acoustic. Design Manual. October 2010 / New Zealand Fire and Acoustic Design Manual October 2010 / New Zealand 1 Contents 2 Introduction 3 3 Application and scope 3 3.1 Application 3 3.2 Scope 3 3.3 Responsibility 3 4 System index 5 5 How to use this manual

More information

Guide to the safe installation of downlighters in dwellings

Guide to the safe installation of downlighters in dwellings Guide to the safe installation of downlighters in dwellings Technical guidance for designers and installers 01 Guide to the safe installation of downlighters in dwellings Technical guidance for designers

More information

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY PERFORMANCE CEILINGS M ore s c op e f or i n n ovat i on AMF Line; wall absorbers Wall mounted acoustic designs MADE IN GERMANY 138568_Prospekt Wandabsorber_GB int.indd 1 Acoustic elements on the wall

More information

Melbourne balcony Assessments

Melbourne balcony Assessments Balcony Assessment Melbourne balcony Assessments Address: SAMPLE Date: Assessor: Luke O Neill Registered Builder DBL-C 31305 Assessment Guidelines This is an assessment of balcony and elements as presented

More information

Mansion on Bourke. 2 Mansion on Bourke Case Study S E R V I C E D A P A R T M E N T S

Mansion on Bourke. 2 Mansion on Bourke Case Study S E R V I C E D A P A R T M E N T S C A S E S T U D Y Mansion on Bourke S E R V I C E D A P A R T M E N T S Mansion on Bourke Mansion on Bourke is a 63 unit apartment complex in Melbourne s central business district at 151-163 Bourke Street.

More information