Charcon Flooring Flexible quality flooring solutions at all levels

Size: px
Start display at page:

Download "Charcon Flooring Flexible quality flooring solutions at all levels"

Transcription

1 Charcon Flooring Flexible quality flooring solutions at all levels

2 02 Delivering value through construction materials With a wealth of technical expertise, and a range of high quality engineered structural stairs, landings and flooring products, Charcon Flooring offers an efficient and versatile solution for any housing or commercial application Beam and block flooring A comprehensive flooring system composed of prestressed concrete beams with standard building blocks laid between them Beamshield Plus flooring A suspended floor insulation system for domestic and commercial applications Tetris flooring A suspended insulation flooring system designed for both domestic and commercial ground floor applications Acoustic separating floors Flooring solution designed to limit or insulate against airborne sound Hollowcore flooring Flooring units that offer the designer and contractor a flexible and economic answer to the challenges posed by flooring spans and widths Accessories A range of flooring accessories Stairs and landings Precast stairs and landings to suit most combinations of architectural design. Aggregate Industries is the first company in the world to achieve a BES 6001:2008 Responsible Sourcing Certificate from BRE Global. All Aggregate Industries UK manufactured products have a certificated minimum rating of GOOD under the BES 6001 standard.

3 03

4 04 Beam and block floors Beam and block is a comprehensive flooring system composed of prestressed concrete beams with standard building blocks laid between them. Together with split course perimeter blocks and professional fixings, they add up, quite simply to a comprehensive flooring package. From the supply of beams only to a complete structural floor, our client need only select those elements that meet their requirements. Beams Beams are prestressed and are available in various profiles, designed in accordance with BS8110 Part 1:1997 using grade C60 concrete and a cover to the reinforcement to satisfy the moderate exposure condition as defined in BS8110 Part 1:1997. Prestressed beams are manufactured in standard lengths of 50mm increments. Blocks Infill blocks should be concrete or aerated concrete blocks generally 440x215x100mm and be minimum 3.5N/mm 2 compressive strength and able to support a transverse load of 3.5kN on a span of 420mm (larger aerated floor blocks are available designed specifically for beam and block floors and can be used with prior consultation with our estimating department). Blocks are100mm thick, solid and manufactured in accordance with BS6073: Block densities between 650kg/m 3 and 2000kg/m 3 are available. Once all joists are in place and have been correctly spaced, infill blocks should be laid over the whole area. Where blocks are built into walls of a higher strength than the infill block, then the general contractor must provide compatible perimeter blocks. Split course blocks have a crushing strength of 7N/mm 2. A concrete cutting saw or block splitter will be required to cut the perimeter blocks and cut rows where necessary. To seal the joints a 4:1 sand cement grout should be brushed over the whole floor area. The floor now provides a safe working platform for following trades. During further construction, never overload the floor with blocks as this could exceed design loadings. Floor finishes The top surface of the beam and block floor is suitable for the application of one of the following (i) Sand/cement screed applied directly over the floor area (ii) A timber T & G floating floor may be laid directly onto a continuous D.P.M. over a levelling screed on the beam and block floor (iii) When additional insulation is required, a layer of insulation material is laid over the floor, which may be completed by either a sand/cement screed or T & G floating floor on D.P.M. A levelling screed is recommended prior to installing the insulation. Benefits Easy to handle, quick to install. Beams and blocks can be easily handled by forklifts or cranes. Smaller lengths can be manhandled Provides immediate working platform. No need to wait for concrete slabs to cure. Grouted floors form an immediate base for following trades Simple all weather form of construction. There is no need to worry about frost damage to floors Draught proof, rot proof and fire resisting. The durability of solid concrete, but as simple to lay as timber Eliminates backfill and site compaction. Expensive backfill and compaction are not required. Subsequent ground heave problems are removed Good thermal insulation. Insulation values required by Building Regulations are easily achieved using the appropriate finishes. Installation 1. Ensure bearings are level and clear of debris 2. Lay DPC and set out first beam in accordance with previously approved and issued layout drawings

5 05 3. Position remaining beams using infill blocks at each end to ensure correct spacing 4. Ensure beams do not project into the cavity 5. Bed split course blocks between ends of beams and along parallel load bearing walls where shown on layout drawings 6. When all beams are in place complete the fixing of the infill blocks 7. A 4:1 sharp sand/cement grout must be thoroughly brushed into all the joists and a C30 concrete is required between multiple beams. The floor should be soaked with clean water prior to grouting if possible 8. Our floors achieve a fire resistance of one hour. This is enhanced by the application of suitable finishes. General notes No prestressed unit is to be cut or drilled without submission to our technical department. Shot-fired fixings are NOT PERMITTED in beams or blocks. Prestressed units have an inherent upward camber and due allowance should be made in any finishes to cater for this. Differential cambers are likely to occur due to manufacturing/construction tolerances or where short and long units are adjacent or at change of direction of spans. Some form of leveling screed by a general contractor is recommended for polystyrene and chipboard or Floating floors to accommodate slight differences in camber and level between top of block and top of beam. Garage floors require a reinforced C30 concrete screed. Holes can be accommodated by the omission of blocks and made good with in situ concrete by the general contractor after the installation of services. Correct 250mm max overhang Place blocks on planks no closer than 1.2m centres measured along the supports. Incorrect Max 2 stacks per span 12 blocks per stack Position lower blocks this way Span/4 Span/2 Span/4 Uneven ground/small bottom bearings/bearers out of line = DAMAGE Place blocks as close as possible to bearing walls. Never double stack block packs. Do not place packs of blocks mid span.

6 06 Beam and block floors Prestressed concrete floor beams MI04 beam Span load tables MI04 150mm deep beams typical application Infill block density kg/m 3 Case S Case S Case S Dry finishes 0.2kN/m 2 65mm screed finish 1.5kN/m 2 Superimposed loadings kn/m 2 Superimposed loadings kn/m Clear spans MR09 beam Span load tables MR09 150mm deep beams typical application Infill block density kg/m 3 Case S Case S Case S Dry finishes 0.2kN/m 2 65mm screed finish 1.5kN/m 2 Superimposed loadings kn/m 2 Superimposed loadings kn/m Clear spans MT10 beam Span load tables MT10 200mm deep beams typical application Infill block density kg/m 3 Case S Case S Case S Dry finishes 0.2kN/m 2 65mm screed finish 1.5kN/m 2 Superimposed loadings kn/m 2 Superimposed loadings kn/m Clear spans

7 07 Prestressed concrete floor beams CR94 beam CR130 beam MR09 beam C225 beam Span load tables CR94 typical application Infill block density kg/m 3 Case S Case S Case S Span load tables C130 typical application Infill block density kg/m 3 Case S Case S Case S Span load tables MR09 typical application Infill block density kg/m 3 Case S Case S Case S Span load tables C225 typical application Infill block density kg/m 3 Case S Case S Case S Dry finishes 0.2kN/m 2 65mm screed finish 1.5kN/m 2 Superimposed loadings kn/m 2 Superimposed loadings kn/m Clear spans Dry finishes 0.2kN/m 2 65mm screed finish 1.5kN/m 2 Superimposed loadings kn/m 2 Superimposed loadings kn/m Clear spans Dry finishes 0.2kN/m 2 65mm screed finish 1.5kN/m 2 Superimposed loadings kn/m 2 Superimposed loadings kn/m Clear spans Dry finishes 0.2kN/m 2 65mm screed finish 1.5kN/m 2 Superimposed loadings kn/m 2 Superimposed loadings kn/m Clear spans

8 08 Beamshield Plus Insulated floors Beamshield Plus floor insulation system is a suspended flooring system for domestic and commercial applications to ground floors excluding garages. The system comprises prestressed concrete beams infilled with purpose designed high duty expanded polystyrene (EPS) panels from Springvale EPS Ltd topped off with a power floated reinforced structural screed finish. From supply only of materials to a complete floor requiring the structural screed, our clients need only select those elements that meet their requirements. Beams Beams are prestressed and are available in various profiles, designed in accordance with BS8110 Part 1:1997 using grade C60 concrete and a cover to the reinforcement to satisfy the moderate exposure condition as defined in BS8110 Part 1:1997. Prestressed beams are manufactured in standard lengths of 50mm increments. EPS infill panels Infill panels are used in place of standard building blocks between the beams and are manufactured in accordance with BS EN 13163: The insulation value of the EPS is more than three times greater than even the most efficient lightweight thermal block so no further insulation is required in the floor structure Because Beamshield Plus is positioned level with the top of the beam, there is no enroachment into the floor void The closed cell lightweight EPS panels are very easy to handle and their design facilitates a very rapid installation The shape of the panels has been carefully developed to eliminate cold bridging giving an average insulation thickness of approximately mm Where necessary the panels can be easily cut with a fine toothed saw to accommodate the most awkward lengths, spans, widths and services Each block measures 1200mm long and covers more than five times the area of a standard building block The EPS panels each weigh approximately 1.5kg and arrive on site in packs wrapped in fours, which can be carried comfortably by one person Chemically inert. Structural floor screed The T beams and EPS infill panels are topped off with a power floated C25/30 concrete structural screed finish by the main contractor. This screed is reinforced with A142 mesh or polypropylene fibres to your concrete supplier s specification. The screed should have a minimum thickness of 60mm from the top of the beams. Benefits Easy to handle, quick to install Blocks can be easily manhandled Simple all weather form of construction There is no need to worry about frost damage to floor Wall to wall EPS insulation with no concrete bridging blocks at floor ends Draught proof, rot proof and fire resisting The durability of solid concrete once the screed is applied, but as simple to lay as timber Eliminates backfill and site compaction Expensive backfill and compaction are not required. Subsequent ground heave problems are removed Good thermal insulation The Beamshield Plus blocks and concrete screed, easily achieve the insulation values required by building regulations and the code for sustainable homes.

9 09 General notes No prestressed unit is to be cut or drilled without submission to our technical department. Shot-fired fixings are NOT PERMITTED in beams or blocks. Prestressed units have an inherent upward camber and due allowance should be made in any finishes to cater for this. Differential cambers are likely to occur due to manufacturing/construction tolerances or where short and long units are adjacent or at change of direction of spans. Either omitting blocks or trimming them with a fine-toothed saw readily accommodates services. Off cuts of reasonable size can be reused so waste is minimised. Installation 1. Ensure bearings are level and clear of debris 2. Lay DPC and set out first beam in accordance with previously approved and issued layout drawings 3. Position remaining beams approximately in correct position 4. Ensure beams do not project into the cavity 5. Ensure that telescopic vents are correctly positioned to ventilate the void and the void is a minimum 150mm below the Beamshield Plus unit 6. Install polystyrene infill blocks. Blocks can be cut using a hand saw to suit service holes and run-out 7. Bed T-shaped concrete closure block along bearing walls 8. Install Beamshield Plus starter block as denoted on the layout drawing 9. Create screed rail/formwork using one of these options: a) 100mm x 50mm Soft wood b) Bedded split course blocks or brick c) Proprietary edge profile (plastic or steel angle) 10. Postion perimeter insulation strip to prevent cold bridging 11. Lay structural concrete screed. U Value Chart U Value (W/m2K) Perimeter/Area Ratio GAS MEMBRANE TO LAP UNDER CAVITY TRAY SPECIFIED TOPPING GROUT INFILL 30mm PERIMETER STRIP BETWEEN BEAMS MEMBRANE IF SPECIFIED 30mm PERIMETER STRIP GAS MEMBRANE TO LAP UNDER CAVITY TRAY EXTERNAL GROUND LEVEL EXTERNAL GROUND LEVEL DPC min 150 mm void DPC STARTER UNIT (MAX. 300mm SPAN) HALF UNIT FULL DOUBLE STANDARD FULL END PANELCUT FROM BEAM UNIT BEAM UNIT FULL UNIT ON SITE (MAX 300 mm SPAN)

10 10 TETRiS floors The TETRiS suspended insulation flooring system is designed for both domestic and commercial ground floor applications, excluding garages. The system comprises prestressed concrete beams in-filled with profiled closed-cell, high compressive strength extruded polystyrene panels, finished with a structural concrete topping. Beams Beams are prestressed and are available in various profiles, designed in accordance with BS8110 Part 1:1997 using grade C60 concrete and a cover to the reinforcement to satisfy the moderate exposure condition as defined in BS8110 Part 1:1997. Prestressed beams are manufactured in standard lengths of 50mm increments. TETRiS panels TETRiS fully recyclable infill panels are used in place of standard building blocks and sit on top (75mm) and between the beams (15-85mm). The insulation value of TETRiS is more than three times better than even the most efficient lightweight thermal block and as a result, no further insulation is required in the floor structure TETRiS panels are very easy to handle and their design facilitates a very rapid installation Once installed, the TETRiS insulation panels produce a floating floor that completely isolates the warm structural slab from the cold concrete beams and any concrete floor blocks used. Around the external perimeter, thermal edge strips protect the vertical edge of the structural slab from cold bridging, fully satisfying the requirements of the Robust Construction Details Where necessary the panels can be easily cut with a fine toothed saw to accommodate the most awkward lengths, spans, widths and services Each panel measures 2500mm long and covers up to sixteen times the area of a standard building block TETRiS panels are delivered to site on bearers in specific plot loads, helping to control cost. TETRiS panels can be easily carried around site and weigh less than 8.2kg. Structural floor screed The T beams and TETRiS panels can be finished with any of the following: 75mm thick RC30 to BS with polymeric monofilament fibres at a dose of 900g/m 3 75mm thick standard C35 concrete 10mm CEM1 slump class 3 to BS8500-1/2 Proprietary self compacting concrete, containing admixtures to BE EN 934, mortar and grout. General notes No prestressed unit is to be cut or drilled without submission to our technical department. Shot-fired fixings are NOT PERMITTED in beams or blocks. Prestressed units have an inherent upward camber and due allowance should be made in any finishes to cater for this. Different cambers are likely to occur due to manufacturing/construction tolerances or where short and long units are adjacent or at change of direction of spans. Either omitting blocks or trimming them with a fine-toothed saw readily accommodates services. Off cuts of reasonable size can be reused so waste is minimised. Benefits Easy to handle, quick to install Panels can be easily installed Simple all weather form of construction There is no need to worry about frost damage to slabs Underfloor heating easily integrated Heating systems can be fixed directly to the TETRiS panels prior to pouring the concrete finish

11 11 Eliminates the need to introduce wet Installation 6. Cut and install blocks and a flat trades later in the building process sheet to cut rows 1. Ensure bearings are level and Installing the finished structural floor clear of debris 7. Construct retaining edge to before the house is built perimeter of floor 2. Lay DPC and set out first beam Good thermal insulation in accordance with previously 8. Pour concrete and level floor The TETRiS system can easily approved and issued achieve the insulation values required 9. If required powerfloat to a layout drawings by Building Regulations. final finish 3. Bed split course and install blocks Helps achieve Code for Sustainable 10. Apply a layer of sand over the to perimeter Homes level 3-6 floor to protect from other trades The TETRiS system has been 4. Break down the plot pallet and during the building process. awarded the highest green guide stack next to beamed area of floor rating available (A+) and will assist in 5. Install TETRiS infill panels in a gaining a high CSH level. staggered pattern. Panels can be cut using a hand saw to suit service holes and run-out Load span table Unit Beam type Design case Floor case width (mm) width (mm) self weight (kn/m 2 ) Screed finish = 1.50 (kn/m 2 ) Superimposed loadings in (kn/m 2 ) Clear spans in metres MHI1 MI MHR1 MR MHT1 MT Calculation of floor U-values 1. Calculate the floor exposed internal perimeter in metres 2. Calculate the floor internal area in metres squared 3. Calculate the perimeter/area ratio 4. Determine the U-value from the graph on page 9 Unheated spaces outside the insulated fabric, such as porches or attached garages, are excluded when determining perimeter and area (but the length of the wall between the heated building and the unheated space is included when determining the perimeter). 1 T - Panel 2 Gap strip 3 Edge strip Fixed 150mm height above beams 1. T-blocks: large insulation blocks (0.75 or 1.5m 2 ) profiled to suit specific prestressed concrete floor beams used, a 75mm section remains above the beams, with the balance dropping between 2. Gap-strips: 75mm thick insulation blocks, used to make up areas that T-blocks do not cover Zero cold bridging 150mm (min) Thickness of insulation between the beams varies depending on U-value required 3. Vertical edge strips: supplied to suit the thickness of concrete finish (65 or 75mm), fixed around the floor s external perimeter to eliminate cold bridging. TFIX: fixing pins used to secure the strips in position.

12 12 Acoustic separating floors - concrete Beam and block solutions for Part E Awareness about noise transmission in the home is increasing. Noise is a modern paradox: we use more noise generating products than ever in the home yet we want increased levels of peace and quiet. A choice of beam and block acoustic flooring solutions are available. Background The 2004 changes to Part E of the Building Regulations, which cover resistance to the passage of sound, have attempted to address noise transmission by improving sound insulation for residential buildings. Part E addresses key areas including separating walls, floors and stairs, internal walls and floors and reverberation in common areas and stipulates minimum performance criteria for airborne sound and impact sound insulation of separating floors. To achieve these standards, housebuilders can either: 1) use their own design and subject it to pre-completion sound testing, the onus being upon the builder to demonstrate that required levels of sound insulation are achieved as detailed in the performance table or 2) choose one of six approved separating floor robust details solutions, which exceed the minimum standard in Part E by at least 5dB and therefore avoid pre-completion sound testing, and associated costs. The minimum value for airborne sound insulation is as shown below: Separating Floors Separating floors are designed to limit or insulate against airborne sound, such as that from a television; impact sound, such as footsteps; and flanking sound - the indirect transfer of sound through the building fabric, usually through the walls separating dwellings. There are four principles to achieving the required sound insulation: Mass: The heavier the floor, the less sound is transmitted. Mass is designed into floors by using concrete or the addition of layers of dense material to timber Completion of the acoustic element: Air gaps and non-uniformity in the floor construction can reduce sound insulation performance. A high standard of installation is required to ensure airtightness and uniformity Flexibility: Flexible floors generally provide better sound insulation. Certain stiffness is required for structural reasons, and certain frequencies of sounds can be transmitted because of resonance Isolation: The physical separation of a floor reduces the transmission of sound through a structure. The installation of a floating floor, which incorporates resilient layers and uses soft or acoustic floor coverings, is the standard option for achieving separation. Ceiling treatment in the room under the floor is just as important as the floor structure and floor covering. Robust details - compliant separating floors The robust details scheme outlines the principal separating floor solutions for concrete flooring. There are 100 variations of ceiling and floor finishes within these headline solutions to satisfy Part E. Concrete floors: There are four robust detail concrete separating floor solutions, which are based on precast concrete beam and block or planks with a directly applied screed, floating screed or in situ concrete slab. A steel deck and in situ concrete composite floor option is also described. Compliance with robust details will negate the requirement for pre-completion site testing of new build separating structures for dwelling houses and flats. To use a robust detail construction, an application must be registered with Robust Details Limited and a fee paid. Further details can be found at Part E (PCT) requirements Robust details requirements Airborne Bnt, w + Ctr >= 45 db >=47dB Impact Lnt,w >= 62 db >= 60dB

13 13

14 14 Acoustic separating floor - concrete E-FC-6 Part-E compliant Beam and block floor with precast or in situ edge beams Screed lid on Regupol E48 resilient layer system For use with dense aggregate block flanking walls only. 1. Screed: 65mm (min) cement:sand screed or 40mm (min) proprietary screed, nominal 80kg/m 2 mass per unit area 2. DPM: 0.2mm (min) waterproof membrane 3. Resilient layer: 8mm Regupol E48, dimple side down, fully lapped up walls and Regupol tape for jointing 4. Structural floor: beam and block, min 100mm thick dense aggregate infill blocks, min 50mm concrete topping, min strength class C20, to floor blocks, min 300kg/m 2 combined mass per unit area 5. Ceiling: Min 300mm from top of beam to ceiling board System installation The use of this screed resilient layer system must incorporate the following: 1) 8mm Regupol E48 (resilient layer to be laid over entire floor area with 50mm overlaps) 2) All joints sealed with Regupol tape 3) 0.2mm (min) waterproof membrane Regupol E48 must be laid dimpled side down Regupol E48 must be turned up at walls and lapped under wall linings and skirting Lay a 0.2mm (min) waterproof membrane over the entire floor. Do Butt floor blocks tightly together Cover floor blocks with min 50mm concrete topping Ensure that concrete does not enter the cavity and bridge the two leaves of supporting wall blockwork it is acceptable to use proprietary cavity stops to provide a shutter Ensure precast or in situ edge beams are correctly installed Ensure in situ concrete downstand is at least 75mm wide Ensure Regupol E48 is laid dimple side down, covers entire floor area and has overlapped joints sealed with Regupol tape Ensure Regupol E48 resilient layer isolates screed from the perimeter walls, wall linings and skirtings Ensure depth from top of beams to ceiling is min 300mm Ensure 50mm mineral fibre quilt is installed over whole ceiling board areas. 1. Regupol tape 2. Min 50mm overlap mm (min) waterproof membrane 4. Regupol E48 lapped under wall linings and skirtings

15 Acoustic separating floor - concrete E-FC-7 Part-E compliant 15 Beam and block floor with precast or in situ edge beams Using floating floor treatments For use with dense aggregate block flanking walls only. 1. Floating floor treatment 2. Structural floor: Beam and block, min 100mm thick dense aggregate infill blocks, min 50mm concrete topping, min strength class C20, to floor blocks, min 300kg/m 2 combined mass per unit area 3. Ceiling: Min 300mm from top of beam to ceiling board Do Butt floor blocks tightly together Cover floor blocks with min 50mm concrete topping Ensure that concrete does not enter the cavity and bridge the two leaves of supporting wall blockwork it is acceptable to use proprietary cavity stops to provide a shutter Ensure precast or in situ edge beams are correctly installed Ensure in situ concrete downstand is at least 75mm wide Ensure levelling screed is applied before using FFT1 or FFT3 (resilient batten) floating floor treatments Ensure quilt is inserted within FFT2 (cradle/saddle) floating floor treatment Ensure floating floor treatment is suitable and install in accordance with manufacturer s instructions Install flanking strips around the perimeter of the flooring board to isolate floor from walls and skirtings Ensure depth from top of beams to ceiling is min 300mm Ensure 25mm mineral fibre quilt is installed over whole ceiling board areas.

16 16 Hollowcore floors Hollowcore units can offer the designer and contractor a flexible and economic answer to flooring challenges, due to the spans and widths of units available. From supply only to a complete structural floor our clients need only select those elements that meet their requirements. When all the hollowcore units are in place and lined up, the joints between the units are to be grouted with either a 3:1 sand/cement mix or C30 concrete with 10mm aggregate. Technical Units are produced on a long line method and come in a range of depths from 100mm to 400mm as shown on the span load table. The standard section is suitable for a moderate exposure condition as defined in BS8110. Finishes Concrete surface finish to soffit is a Type A finish as described in BS8110 Part 1:1997. Clause Where a plaster finish is intended it may be necessary to use a bonding agent in accordance with the manufacturer s instructions. Suspended ceilings are the preferred choice when hollowcore units are used. The soffits are not suitable to be painted without finishes being applied. Units may accumulate water within the cores due to exposure during the construction programme. The general contractor should drill weep holes as necessary. Installation 1. Ensure bearings are level and clear of debris 2. If applicable, lay DPC prior to placing first unit in accordance with previously approved and issued layout drawings 3. Position remaining units in sequence working away from the first 4. Bar up units tight to each other after chains have been removed 5. Ensure all unit ends are in line and do not project into the cavity or overhang steelwork 6. When all units are in place and lined up, the joints between are to be grouted with C30 concrete 7. All grouting must be completed before subsequent works continue. Unit depth Self weight (kn/m 2 ) Slab load/span table Screed finish = 1.5 (kn/m 2 ) Superimposed loadings in (kn/m 2 ) Clear spans in metres 100mm* mm ss mm mm mm mm mm mm * 100mm SOLID slab is tabulated with 75mm bonded structural screed. The flexibility of Hollowcore design Hollowcore units are available in various options including solid ends, open cores, raking cuts, holes and notches.

17 17 General notes No prestressed unit to be cut or drilled without submission to, and agreement with, our technical department. Shot-fired fixings are NOT PERMITTED in hollowcore units. Prestressed units have an inherent upward camber and due allowance should be made in any finishes to cater for this. Differential cambers are likely to occur due to manufacturing/construction tolerances or where short and long units are adjacent or at the change of direction of spans. Unit cambers will be generally in accordance with the recommendations of BS8110 and are predicted to be approximately 1/300th of the span. Some form of leveling screed by a general contractor is recommended for polystyrene and chipboard or floating type floors to accommodate slight differences in camber and level between units. Typically prestressed floor units will provide a fire resistance of one hour, however, ratings in excess of this can be supplied if necessary. Small holes up to 50mm diameter can be drilled on site. Larger holes can be formed during manufacture, dependent on design criteria.

18 18 Flooring accessories Void Ventilators Adequate sub floor ventilation is required under suspended floors to assist in reducing condensation and dry rot damage. Air vents and bricks should be installed approximately every 2m. (See Building Regulations 1991 Approved Document C 1992 edition.) Installation No special fixings are required. Installation is easily carried out as work proceeds. Adjust the height of the vent to suit courses and height of floor. Colours: Black. Air Bricks High airflow allows suitability in many applications. Louvres promote unrestricted airflow and reduce the risk of blockage as well as keeping large insects out. Installation No special fixings are required. Colours: Blue/Black, Terracotta, Buff. Split Course Split Course bricks have a minimum 7N/mm 2 compressive strength. Designed to be bedded top and bottom, they are available in the following sizes: 150mm Floors: Sizes: 385mm long, 100mm/140mm wide, 40mm deep. Pack Sizes: 168No, 336No. 200mm / 225mm Floors: Sizes: 195mm long, 100mm wide, 95mm deep. Pack Sizes: 180No, 360No.

19 19 Trimmer Angles Steel trimmer angles can be utilised to trim service voids or create openings through the floor. Where a void created by removing blocks from between the beams is insufficient, then a steel angle painted with one coat of protective paint can be used. Supplied to a maximum of 1.2m long. Butt Plates Galvanised steel units to overcome localised butt seating requirements, which cannot be accommodated on the wall. Manufactured to suit either 100mm or 140mm wide walls. Butt Plates are available in two sizes: BC1-160mm long to suit individual beams. BC3-480mm long to suit double or triple beams. Ceiling Clips Ceiling batten support clips are inserted from below the floor; at the time the timber battens are being fixed. This is to ensure their correct position. The top of the clip has a galvanised steel plate bent at right angles to allow the clip to be knocked into place. This plate wedges between the shoulder of the beam and the block. The legs are designed to allow for bending or twisting around the timber battens. The pre-drilled holes accommodate nails or screws for fixings. Counter battens or propriety ceiling systems can then be installed.

20 20 Stairs and landings Precast stairs and landings are available to suit most combinations of architectural design. Straight flights or integral top and bottom landings are available offered with unit widths, riser and tread dimensions to suit. Precast components are designed and manufactured to suit the clients requirements before leaving the factory. Speed of installation reduces risk and cuts cost. Installation is rapid providing instant and safe access between floor levels. Benefits Straight flights or integral top and bottom landings are available Width, riser and tread dimensions to suit Stepped landings. Speed Precast components are designed and manufactured to suit the building before leaving the factory. Speed of construction reduces risk and cuts costs. Installation is rapid providing instant safe access between floor levels. Design Structural design is in accordance with BS8110 Part 1: The Structural Use of Concrete and the client s loading specification. Stair dimensions will be in accordance with the client s specifications, which should usually comply with the requirements of the Building Regulations Approved Documents B, K & M. and are then submitted for approval prior to manufacture. Finishes Stairs and landings are manufactured in moulds which produce Type A finishes as described in clause of BS8110 Part 1: The soffit is a high quality steel float finish in accordance with NSCS specification section 4. The precast units will require some making good and the lifting points will need grouting in after installation. Lifting points Each precast stair and landing unit will have between two and four lifting points for off-loading and placing the units. Please contact the sales office at the time of ordering to confirm the type of lifting clutches being used. Fire resistance Stairs and landings will achieve a fire resistance of one hour. Higher fire resistance ratings can be achieved where specified by the client. Durability Precast concrete is unaffected by climatic conditions and is suitable for external and internal use. Balustrade fixings It is recommended that the main contractor should drill fixings for balustrade on site. A minimum dimension of 50mm should be allowed between the edge of any pocket or fixing and the edge of the concrete.

21 21 Precast stairs and landings Return landing Support landing Support landing Finishes to suit architect s requirements Tread and riser units Tread and riser units can be used where large precast stairs and landings are not suitable. Benefits Easy to handle and built into spine walls to suit progress of the building Variable width, rise and tread dimensions Can be used internally and externally with finishes applied to the units. Speed Installation is rapid providing safe access between floor levels. No crane or plant required for installation. Dimensions LENGTH GOING RISE max. 1400mm max. 300mm max. 220mm All units are easily positioned on each other to obtain the required going dimension.

22 22 Other structural solutions in precast Aggregate Industries provides a huge range of civil engineering and construction solutions in precast concrete. We can manufacture products to any project requirement. Please call us for further information. Railway platform products Stadiums and terracing Beams, columns, walls, and roof slabs Precast stairs, landings Sea defences Architectural dressings, walling and flooring and roof tiles Product development Charcon Flooring has a policy of continuous product development and product information is subject to change without notice. All products are manufactured to the appropriate British, (BS) standard or harmonised European standards, (BS EN) wherever possible. If no standard currently exists then Charcon Flooring s own standard is applied. All products are supplied subject to Charcon Flooring s Terms and Conditions of Sale, a copy of which is available on request. Use of information within literature The designs shown in this literature are illustrative only, and all dimensions are nominal. Every effort is made to ensure the accuracy of all textual and pictorial content in this guide. No charge is levied for this brochure or the advice therein, and accordingly the company, its employees and authorised agents can accept no liability whatsoever, either indirectly or directly arising from the use of its products in connection with any information or advice contained in this guide. It is the responsibility of clients and installers to check that installations achieve the appropriate standard. The relevant British or European standard should be referenced at all times.

23 Aggregate Industries The complete service 23 Charcon Flooring is part of the Aggregate Industries group offering an extensive range of products and services to the construction industry. Structural Solutions Charcon Precast Solutions Charcon Precast Solutions supplies and installs precast stairs, landings and bespoke solutions for all specifications. South Tel: Midlands Tel: North Tel: Bradstone Structural Solutions Supplier of walling, roofing and cast stone architectural dressings for commercial and domestic building projects throughout the UK. Tel: Charcon Specialist Products Supplier of civil engineering products including service protection ducting, covers, markers and posts as well as rail platform products, highway furniture and filter bed wall and tile units. Tel: Other Aggregate Industries businesses Bardon Concrete Bardon Concrete (and London Concrete within the M25) offers a complete range of ready-mixed concretes and screeds, operating from over 50 sites. The Elite Minimix operation caters for smaller collect loads. Bardon Concrete Tel: bardon.concrete@aggregate.com London Concrete Tel: london.concrete@aggregate.com Charcon Charcon flag paving, block paving and kerb products are available in both concrete and natural stone. Surface water drainage and SUDS are also part of a wide ranging product portfolio. Bardon Aggregates Bardon Aggregates supplies crushed rock, sand and gravel and fill materials. These can be delivered by road, rail or marine transport. Tel: midlands.sales@aggregate.com Bardon Asphalt Bardon Asphalt is a leading supplier of a full range of coated materials with over 50 locations in the UK, serving major conurbations, including Express Asphalt sites for collect business. Tel: midlands.sales@aggregate.com Tel: sales.charcon@aggregate.com

24 Charcon Flooring South Rowan House, Sheldon Business Park Chippenham, Wiltshire SN14 0SQ Tel: +44 (0) Fax: +44 (0) Charcon Flooring North Stephenson Way, Barrington Industrial Estate Bedlington, Northumberland NE22 7DL Tel: +44 (0) Fax: +44 (0) Founding Member Aggregate Industries UK Limited. February 2010

PRESTRESSED CONCRETE FLOORING BEAMS

PRESTRESSED CONCRETE FLOORING BEAMS PRESTRESSED CONCRETE FLOORING BEAMS TRIED & TRUSTED Introduction Established in 2001 TT Concrete Products Limited has become a prominent manufacturer of prestressed concrete flooring beams throughout the

More information

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with Section Separating Floors Timber frame floor with I-Beams Product: Earthwool Acoustic Roll and Floorfoam Easy Edge Strip Timber frame floor with solid timber joists Product: Earthwool Acoustic Roll and

More information

Rockwool Flexi Insulation Application Guide

Rockwool Flexi Insulation Application Guide Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed

More information

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01. Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice

More information

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,

More information

Energy Company Obligation (ECO): Technical Monitoring Questions

Energy Company Obligation (ECO): Technical Monitoring Questions Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified

More information

Hanson Building Products. precast basement solutions

Hanson Building Products. precast basement solutions Hanson Building Products precast basement solutions Hanson Building Products Basement Systems Add an extra dimension and combine the inherent flexible, structural and waterproof properties of concrete

More information

Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February 2008. Foundation Heave Protection

Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February 2008. Foundation Heave Protection Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February 2008 Foundation Heave Protection The safe, sure way to provide foundation protection Clayshield is the proven solution to protecting foundations against

More information

Beam & Block Floors. The complete guide

Beam & Block Floors. The complete guide Beam & Block Floors The complete guide 2 3 Content A complete and seamless beam and block flooring solution Sustainability 4 Domestic Ground Floor 6 Domestic First and subsequent floors 7 Domestic Load

More information

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available. APR 1200 Acoustic Partition Roll CI/Sfb Ref: APR002 Glass mineral wool roll designed to provide high levels of sound insulation in walls and floors to meet Part E (England & Wales) and Section 5 (Scotland)

More information

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS

More information

Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37

Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37 Contents Pages Full fill cavity walls 2-13 Partial fill cavity walls 14-25 Solid externally insulated walls 26-37 Appendix (BRE confirmation of Ψ and y-values) 38-40 Page 1 of 40 APA Construction Details

More information

Multi-layer Insulation Blanket for Roofs

Multi-layer Insulation Blanket for Roofs Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof

More information

Timber Decks. Technical Note. March 2007

Timber Decks. Technical Note. March 2007 Timber Decks Technical Note. March 2007 This Technical Note contains general information for residential timber decks and floor frame structures for veranda s, patios etc which are exposed to the weather.

More information

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap Tile Backing Will not deteriorate in water Easy to score and snap Resistant to mould and mildew Knauf Aquapanel Interior Cement board for wet areas Knauf Aquapanel Interior Cement Board Drywall for Wet

More information

plumbing products guide

plumbing products guide plumbing products guide radiator pipe guide & seals A significant development in the drive to reduce air leakage and heat loss. Installations such as that shown are all too common. The detail is poorly

More information

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003) NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:

More information

DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP

DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP CONTENTS WHAT IS RISING DAMP STEP 1 SURVEY STEP 2 METER READINGS STEP 3 CONCLUSION STEP 4 PREPARATION FOR TREATMENT STEP 5 TYPE OF TREATMENT STEP 6

More information

sound reduction systems for commercial, educational and industrial environments

sound reduction systems for commercial, educational and industrial environments sound reduction systems for commercial, educational and industrial environments Tel: +44 ()14 3874 Fax: +44 ()14 38957 E-mail: info@soundreduction.co.uk Web: www.soundreduction.co.uk soundblocker Acoustic

More information

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035 Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí

More information

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE TECHNICAL SPECIFICATION PART 8000 - PRECAST CONCRETE TABLE OF CONTENTS Item Number Page 8100 PRECAST CONCRETE CONSTRUCTION - GENERAL 8-3 8101 General

More information

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors Improving the flood resistance of your home Advice sheet 6: Flood-resilient This sheet provides guidance on identifying different types of floor, assessing the routes floodwater may enter, and describes

More information

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab, DESIGN OF SLABS Dr. G. P. Chandradhara Professor of Civil Engineering S. J. College of Engineering Mysore 1. GENERAL A slab is a flat two dimensional planar structural element having thickness small compared

More information

Structural Products. CI/SfB (23) Nh2 P356 August 2008

Structural Products. CI/SfB (23) Nh2 P356 August 2008 Structural Products CI/SfB (23) Nh2 P356 August 2008 Kingspan Toolkit Kingspan Multideck Design Software, for the analysis and design of composite slabs and the selection of the correct Multideck product,

More information

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles INSTALLATION RECOMMENDATIONS Outdoor Rubber Tiles Prior to Installation: The Outdoor Rubber Tiles and accessory transition pieces intended for this installation have been shipped to you via a freight carrier

More information

GRC Porticos. Lightweight entrance porticos ABBEY ARTSTONE

GRC Porticos. Lightweight entrance porticos ABBEY ARTSTONE GRC Porticos Lightweight entrance porticos ABBEY ARTSTONE GRC Porticos Lightweight entrance porticos Abbey Artstone's range of lightweight products designed for the construction industry is the only range

More information

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

CHESTERFLEX ROOF WATERPROOFING MEMBRANES CI/SfB (47) Ln2 Chesterfelt Ltd CHESTERFLEX ROOF WATERPROOFING MEMBRANES Certificate No 94/3062 DETAIL SHEET 2 Product THIS DETAIL SHEET RELATES TO CHESTERFLEX ROOF WATERPROOFING MEMBRANES, POLYESTER REINFORCED

More information

SECTION 7: C - STRUCTURAL ENGINEERS SPECIFICATIONS

SECTION 7: C - STRUCTURAL ENGINEERS SPECIFICATIONS SECTION 7: C - STRUCTURAL ENGINEERS SPECIFICATIONS SITE C SHOPPING CENTRE, KHAYELITSHA PROJECT NO 2369 Project Specification Refer all queries to: John Meiring Tel: +27 21 425 0065 REVISION P01 E-mail:

More information

How to build a Pizza Oven in 4 days

How to build a Pizza Oven in 4 days How to build a Pizza Oven in 4 days Preparation day (slab) 1. Foundation 1500 deep x 1300 wide x 75mm deep Required 20 bags cement pre mix. If you already have a concrete base, you save this prep day DAY

More information

If stepping is required, step at 180mm as seen in this picture.

If stepping is required, step at 180mm as seen in this picture. Cast Foundations to standard building regulations requirements. Foundations must be cast completely level, 600mm wide by 230mm deep for single storey, double storey is not allowed by NHBRC. If stepping

More information

Asphalt Shingle Application Requirements

Asphalt Shingle Application Requirements Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt

More information

RIW SHEETSEAL 226 BENEFITS APPLICATIONS APPLIED TO. CI/SfB TN6 L6813. November 2013. l Water and water vapour barrier. l Factory controlled thickness

RIW SHEETSEAL 226 BENEFITS APPLICATIONS APPLIED TO. CI/SfB TN6 L6813. November 2013. l Water and water vapour barrier. l Factory controlled thickness CI/SfB TN6 L6813 November 2013 RIW SHEETSEAL 226 is a cold applied, high density polyethylene film, coated with a bitumen/rubber self adhesive layer with a removable reinforced silicone paper. Primer is

More information

Chapter 3 Pre-Installation, Foundations and Piers

Chapter 3 Pre-Installation, Foundations and Piers Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory

More information

The WANZ Guide to Window Installation

The WANZ Guide to Window Installation The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 Ver. 1.1 Page 2 of 74 Contents Overview Page 5 Objective Page 5 Scope Page 5 Opening Preparation Page 7 Step P1 Preliminary Check

More information

Precast Concrete Solutions

Precast Concrete Solutions CONCRETE GROUP Precast Concrete Solutions BEAM & BLOCK FLOORS HOLLOWCORE FLOORS PRECAST CONCRETE STAIRCASES WATER CHAMBERS RETAINING WALL SOLUTIONS RESERVOIR WALL Company History CONCRETE GROUP Founded

More information

LAYING BLOCK AND BRICK

LAYING BLOCK AND BRICK LAYING BLOCK AND BRICK Products highlighted in this section: SAKRETE Type N Mortar Mix SAKRETE Type S Mortar Mix Brick And Block Laying Basics The first step in building a brick or block wall is to construct

More information

Module 3.7. Thermal bridging

Module 3.7. Thermal bridging Module 3.7 Thermal bridging Learning Outcomes On successful completion of this module learners will be able to - Describe construction details which influence thermal bridging. 2 Introduction to thermal

More information

BETONYP building boards. The modern way of living.

BETONYP building boards. The modern way of living. BETONYP building boards The modern way of living. Tough for 30 years. Healthy, debarked pine wood and cement: the raw materials used to produce one of our most successful products for more than three decades.

More information

CI SfB. (4-) Nn2. Onduline. Mini Profile. Onduline Garden Roof Range. Onduline Building Products Ltd

CI SfB. (4-) Nn2. Onduline. Mini Profile. Onduline Garden Roof Range. Onduline Building Products Ltd CI SfB (4-) Nn2 Onduline Mini Profile Onduline Garden Roof Range Onduline Building Products Ltd Onduline Garden Roof Range Onduline Mini Profile The new Onduline Mini Profile sheets have been designed

More information

Chapter 2 Basis of design and materials

Chapter 2 Basis of design and materials Chapter 2 Basis of design and materials 2.1 Structural action It is necessary to start a design by deciding on the type and layout of structure to be used. Tentative sizes must be allocated to each structural

More information

GYPSUM AREA SEPARATION FIREWALLS GA-620-2011

GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GA-620-2011 Copyright 2011 Gypsum Association All rights reserved. Printed in U.S.A. Characteristics, properties, or performance of materials or systems herein

More information

Chapter. Restoration of Damaged Structures

Chapter. Restoration of Damaged Structures 5 Chapter Restoration of Damaged Structures Bringing back a damaged structure to its pre-earthquake state and original strength is called restoration. This is the first step of building rehabilitation.

More information

Composite Panel Firewall Systems

Composite Panel Firewall Systems Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.

More information

Rockwool Cladding Roll

Rockwool Cladding Roll Rockwool Cladding Roll High performance industrial insulation has been specifically developed for use in lightweight cladding applications to commercial or industrial framed buildings. Cladding Roll U/F

More information

Manual lifting and handling

Manual lifting and handling Manual lifting and handling When installing British Gypsum products and systems care should be taken to ensure that appropriate methods of handling and lifting are adopted. The following guidance details

More information

Dubai Municipality Standard DMS 1: Part 5: 2004

Dubai Municipality Standard DMS 1: Part 5: 2004 Specification for precast concrete blocks Part 5: Normal-weight concrete-polystyrene sandwich masonry blocks Issue Date Revision Revision Description Prepared by Approved by Authorized by 19/12/2004 Issue

More information

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS NOISE TECHNICAL FACT SHEET FACT SHEET 5 SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS The sound insulation of exterior walls and roof-ceiling systems refers to their ability to reduce external

More information

Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.

Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls. Improving the flood resistance of your home Advice sheet 4: Flood-resilient walls. This sheet provides guidance on identifying different types of wall, and reducing the flow of floodwater through them

More information

0331 Brick and block construction

0331 Brick and block construction 0331 BRICK AND BLOCK CONSTRUCTION This worksection has been written for Class 1 and 10a buildings that fully conform to the scope of AS 4773.1. If the works include isolated structures, (totally separate

More information

The Pocket Guide To Insulation August 2013

The Pocket Guide To Insulation August 2013 The Pocket Guide To Insulation August 2013 Introduction Knauf Insulation is the UK s leading manufacturer of insulation products, including: Earthwool glass and rock mineral wool Polyfoam ECO extruded

More information

Construction. Pre-Bagged Structural Waterproofing System. Product Description. Product Data. Tests. Form

Construction. Pre-Bagged Structural Waterproofing System. Product Description. Product Data. Tests. Form Construction Product Data Sheet Edition 15/07/2013 Identification no: 01 07 05 04 001 0 000001 Sika 1 Pre-Bagged Structural Waterproofing System Product Description Pre-Bagged Structural Waterproofing

More information

How to build raised beds page

How to build raised beds page This leaflet has information to help you if you want to build a raised bed yourself or if you need information to give to a professional contractor. This information should be read in conjunction with

More information

HfHMD uses LP SmartSide siding and trim.

HfHMD uses LP SmartSide siding and trim. HfHMD uses LP SmartSide siding and trim. These products are: More durable than cement fiber board. Much more volunteer-friendly to install. When installed correctly, have a 5/50- year pro-rated warranty.

More information

ProRox Slabs (formerly known as RW slabs)

ProRox Slabs (formerly known as RW slabs) Slabs (formerly known as RW slabs) Versatile thermal acoustic insulation slabs ROCKWOOL's Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation. They are

More information

COMMONLY USED RESIDENTIAL BUILDING CODES

COMMONLY USED RESIDENTIAL BUILDING CODES COMMONLY USED RESIDENTIAL BUILDING CODES INTERNATIONAL RESIDENTIAL CODE (2009) form revised 5/10 FOUNDATION 1. DESIGN OF FORMWORK. Section 1906.1 IBC 2009, Section R404.1.2.3.6 IRC 2009, ACI 318 Section

More information

PB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection

PB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection PB301 July 2009 Lightweight Building Solutions Bushfire Protection www.boral.com.au/bushfireprotection Attached or adjacent within 6m roofed structures such as garages, carports, verandas and the like,

More information

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM P r o d u c t a p p l i c a t i o n s a n d t e c h n i c a l i n f o r m a t i o n 2 below and above ground V OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM V The flexible, fast and cost-effective answer

More information

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory

More information

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01 Section Built-up Metal Roofs Rail and bracket system Product: Earthwool FactoryClad range Bu01 Standing seam system Product: Earthwool FactoryClad range and Earthwool Universal Slab Bu02 Built-up Metal

More information

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW Insulated Roof & Wall Panels Trapezoidal Insulated Roof Panels KS1000 RW Overview Kingspan roof panel systems present a superior system compared to conventional multi-part site assembled systems. They

More information

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery Part 3 Ancillary technologies Chapter CONTENTS SCOPE Clause Page DESIGN Design standards D1 1 Statutory requirements D2 1 System design D3 1 Building integration D4 2 Noise D5 2 Access and controls D6

More information

Rochdale Building Control Guide. Approved Document C. Site preparation and resistance to contaminants and moisture

Rochdale Building Control Guide. Approved Document C. Site preparation and resistance to contaminants and moisture Rochdale Building Control Guide Approved Document C Site preparation and resistance to contaminants and moisture Dampness is often misdiagnosed within buildings, the approved document deals with prevention

More information

7. Installation. installation 7.1.1. CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

7. Installation. installation 7.1.1. CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME 7. Installation Window involves the fixing of window frame at an earlier construction stage and subsequent of the window sashes. This is a highly workmanship dependent process. Only trained and approved

More information

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................

More information

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology Modern Efficient Performance Cost Effective Flat Roofing Systems Introduction A complete range of Memtec Roofing and Waterproofing Single

More information

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas Powerpanel H 2 O is a cement based board from FERMACELL. Board Characteristics Board Thickness 12.5 mm Board Sizes 1000 x 1200 mm 50 sheets/pallet

More information

Residential Foundations and Basements

Residential Foundations and Basements Residential Foundations and Basements Disclaimer All of the following information is based on the 2006 International Residential Code with Kentucky Amendments. As some information is paraphrased, article

More information

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS. Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS. Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance

More information

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing Good Craftsmanship Guide Carpentry and Joinery- Carcassing Introduction This Good Craftsmanship Guide highlights key problems with the major elements of Carpentry and Joinery - Carcassing, and gives guidance

More information

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE 86 :: Certificate in Construction Supervision (CIVIL) 12 ROOF 12.1 INTRODUCTION The structure provided to cover the house surface (floor) is known as roof. For different situation and requirement, it is

More information

Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining Section Timber Frame Walls Single layer between studs Product: Earthwool FrameTherm Rolls and Slabs Tf01 Single layer between studs with service void Product: Earthwool FrameTherm Rolls and Slabs Tf02

More information

Simplifying design and construction. Alan Tovey, Director The Basement Information Centre

Simplifying design and construction. Alan Tovey, Director The Basement Information Centre Simplifying design and construction Alan Tovey, Director The Basement Information Centre Simplifying design and construction Grades of construction Construction options Design and waterproofing issues

More information

FUTURE SLAB. PENETRATIONS and. DEMOLITION of POST-TENSIONED FLOORS

FUTURE SLAB. PENETRATIONS and. DEMOLITION of POST-TENSIONED FLOORS FUTURE SLAB PENETRATIONS and DEMOLITION of POST-TENSIONED FLOORS 1.0 INTRODUCTION Post-tensioned floor slabs in Australia and South East Asia are now universally regarded as the most cost effective form

More information

I-Line - Snap-On Feature

I-Line - Snap-On Feature Oct 2012 I-Line - Snap-On Feature DATA SHEET Snap-On features - Guaranteed truelines every time Bailey I-Line Snap-On is an architectural cladding feature offering creative possibilities for architects

More information

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight

More information

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5 Cl Sfb (27-9) Rn7 M2 December 2004 Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5 Fesco, Fesco S, Retrofit, Retrofit S, Fesco Fillet, PF,

More information

Understanding BS EN 771-3: Aggregate concrete masonry units

Understanding BS EN 771-3: Aggregate concrete masonry units 60 Charles Street, Leicester LE1 1FB Tel: 0116 253 6161 Fax: 0116 251 4568 Email: enquiries@cba-blocks.org.uk Website: www.cba-blocks.org.uk February 2006 Understanding BS EN 771-3: Aggregate concrete

More information

Residential Deck Safety, Construction, and Repair

Residential Deck Safety, Construction, and Repair Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the

More information

ROCKWOOL Rigid, Semi-rigid and Flexible Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation.

ROCKWOOL Rigid, Semi-rigid and Flexible Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation. Rigid, Semirigid and Flexible Slabs Versatile thermal acoustic insulation slabs ROCKWOOL are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation. They are manufactured

More information

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side

More information

Mold Preventing I nterior System

Mold Preventing I nterior System interior insulation and renovation boards A system of components that have been designed to work perfectly together to repair damage caused by mold. The system consists of boards, insulation wedges, reveal

More information

BILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP"

BILL OF QUANTITY FOR THE WORK OF REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP BILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP" Sl. 1 DISMANTLING WORK 1.1 Stripping off worn out plaster (outside and inside) and raking out joints

More information

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1 Top plate Stud Soffit lining 45mm min nog Fix scotia bead Building underlay/james Hardie rigid air barrier Soffit Detail Building underlay/james Hardie rigid air barrier Bottom plate 25mm wide cant strip.

More information

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Services Enclosures and Protected Shafts - Maintaining Compartmentation Introduction When a fire resisting element is used to provide fire compartmentation, every opening that allows services to pass through the element must be adequately protected by sealing, or fire stopping

More information

GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS

GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS 13.1 13.2 2006 Edition SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS GENERAL

More information

STEP-BY-STEP. construction guide. Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet.

STEP-BY-STEP. construction guide. Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet. STEP-BY-STEP construction guide Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet. Welcome to our CONSERVATORY AND SUNROOM CONSTRUCTION GUIDE What is the specification

More information

The WANZ Guide to Window Installation

The WANZ Guide to Window Installation The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 2 of 60 Contents Overview 5 Objective 5 Scope 5 Opening Preparation 7 Step P1 Preliminary Check 8 Step P2 Cut the Underlay 9 Step

More information

Including. Rubershield-Pro. Breather Membrane

Including. Rubershield-Pro. Breather Membrane Including RubershieldPro Breather Membrane 2 Ruberoid produces a wide range of underslating membranes, primarily to be installed below tiles, slates or metal roofing providing a secondary barrier against

More information

Welded Fabric. The CARES Guide to Reinforcing Steels Part 5. Installation of welded fabric on a major contract. 1.0 Introduction

Welded Fabric. The CARES Guide to Reinforcing Steels Part 5. Installation of welded fabric on a major contract. 1.0 Introduction Welded Fabric 1.0 Introduction Welded fabric, often referred to as mesh, is a machine welded grid arrangement of reinforcing bars or wires. It is covered by British Standard BS4483. This was revised in

More information

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades Construction Sika For Sealing and Waterproofing Construction Gaps in Building Façades Waterproof and Airtight Flexible Seal Controlled Vapour Diffusion Bonds to any Building Substrate Prevents Interstitial

More information

Residential Decks. Planning and Development Services Department

Residential Decks. Planning and Development Services Department Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: permitservices@opkansas.org Planning and Development Services Department Residential Decks

More information

This seminar covers the principles, design and installation of ground bearing and suspended insulated floors. You will discover

This seminar covers the principles, design and installation of ground bearing and suspended insulated floors. You will discover Dow Construction Products Thermal Insulation of Floors This seminar covers the principles, design and installation of ground bearing and suspended insulated floors. You will discover Why a floor should

More information

Sports Buildings: budget costs for the Flood Relief Fund

Sports Buildings: budget costs for the Flood Relief Fund Sports Buildings: budget costs for the Flood Relief Fund The list below provides typical costs for flood insurance works, typically required by sports clubs or facilities. The list is not exhaustive but

More information

Confort 26. Sliding Systems. Sapa Building System

Confort 26. Sliding Systems. Sapa Building System Confort 26 Sliding Systems Sapa Building System Confort 26 is Sapa s thermally insulated sliding system for windows and doors. Available as two- and three-rail solution. Among its features, there are

More information

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.) Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.) Gyproc Plasters The cracks in cement sand plaster are an inherent feature which cannot be completely prevented but can only be controlled and

More information

FIRE RATED GLAZING System Guide

FIRE RATED GLAZING System Guide SYSTEM GUIDE Issue date: 05-05-2015 Expiry date: 31-12-2016 System Guide Introduction Pyropanel Developments are specialists in fire rated glazing solutions, and our systems are designed for easy installation

More information

Technology at its best. Benefits

Technology at its best. Benefits Protecting what s under your roof from the elements is simplicity itself with Ruberoid Roofing Shingles. Roofing Shingles make ideal roofing; they are attractive, easy to install and are perfect for use

More information

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING 6.CW.1A TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS wood or gas standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING The Fireplace Ltd is able to design and fabricate custom brick open masonry

More information

ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION

ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 E1 E2 E3 E4 E Protection against sound from other parts of the building and adjoining buildings Protection against

More information

Concrete for industrial floors

Concrete for industrial floors Published October 2000 Reprinted October 2004 One of a series of publications produced in conjunction with the following organizations, and part-funded by DETR. Association of Concrete Industrial Flooring

More information