How To Install Framecad Fibre Cement Sheeting

Size: px
Start display at page:

Download "How To Install Framecad Fibre Cement Sheeting"

Transcription

1 Fibre Cement Technical Guide Fibre Cement Technical Guide for Cold Formed Steel Construction Complies with; ASTM C1186 BS 476 ASTM G-21 FRAMECAD 2013

2 Building Products and Supply Chain Logistics for our Global Customers FRAMECAD has been successfully serving the world s building industry for more than 25 years. Our expert team combines the know-how from over 900 combined years of global experience. FRAMECAD puts this experience to work to help our customers succeed. With FRAMECAD Certified Building Products and world class supply chain logistics, you can turn architectural inspiration into commercial reality much faster and more cost effectively than ever before. FRAMECAD Building Products specialises in developing and supplying global customers with materials that are fit for purpose, tested, designed and engineered by our in-house engineers and technicians that enable of modern methods of construction. Our focus has always been on developing practical building products and solutions that streamline the steel framed building design and build process, cutting production time and delivering a better end result. DESIGN & BUILD SYSTEM

3 Contents: FRAMECAD Fibre Cement Sheeting Product Information Product Certification Page 1 Fibre Cement Board Sizes Page 2 Properties of FRAMECAD Fibre Cement Board Page 3 Storage and Handling Page 4 Cutting Page 5 Installation - For FRAMECAD Cold Formed Steel frames FRAMECAD Specified Fasteners (X-Drive ) Page 6 Detail Drawings Door Installation Page 7 Window Installation Page 8 Render jointing System Page 9 Internal and External Corner Page10 Opening (Door/Window) Page 11 Health and Saftey Page 13

4 FRAMECAD Fibre Cement Sheets FRAMECAD Fibre Cement Sheeting is a high density sheet ideally suited for exterior cladding, interior lining and Flooring FRAMECAD Fibre Cement complies with; ASTM C :2002 (Type B) - Density - Flexural Strength - Moisture absorption, EQ moisture content and moisture movement BS Class A (GB ) - Reaction to fire - More than 2 hours high fire rating for interior wall system - No failure at 120 minutes ASTM G-21 - Non nutrient to mould, fungus or insect life Manufacturing FRAMECAD Fibre Cement Sheeting is a strong and flexible board composed of Portland Cement, refined ores, and reinforced cellulose fibre as the main materials. It is made under high temperature and pressure which generates a light weight, durable and smooth-faced board for various applications. FRAMECAD Fibre Cement Sheeting is a light weight energy saving building panel with non-asbestos fibre that is treated by high temperature and high pressure autoclave process, in accordance with ISP Page 1

5 Applications Ideal for Cold Formed Steel residential and commercial constructions. Applications include; Exterior Wall Cladding Interior Linings Soffits Gable Ends Sizes and packaging Metric Dimensions Application Imperial Dimensions Application Thickness (inch) Width (Feet) Length (Feet) Approximate Packaging Per 20 container Soffit / Ceiling 3/ Sheets Ceiling / Lining 1/ Sheets Lining / Cladding Exterior Siding (Wood Grain) Thickness (mm) Width (mm) Length (mm) / Sheets 1/ Sheets 5/ Sheets... Flooring 7/ sheets FRAMECAD Fibre Cement Sheets is available in a range of imperial and metric dimensions. If not listed as above please contact us with your inquiry. NOTE: FRAMECAD Fibre Cement Sheets 6mm (1/4 ) and 9mm (3/8 ) also available with a tapered edge (TE) or square edge (SE). Always leave a 3mm gap between boards which is later filled using the FRAMECAD Mineral Render System.. Approximate Packaging Per 20 container Soffit / Ceiling / Sheets Ceiling / Lining / Sheets Lining / Cladding Exterior Siding (Wood Grain) / Sheets / Sheets 8 210/ Sheets... Flooring / sheets Page 2

6 Physical Properties Item Parameter Item Parameter Density > 1200 kg/m 3 Biological No Fungus Growth Diagonal & Thickness Tolerance +/- 0.4mm Water Absorption 29.5% Moisture Movement 0.054% Transverse 11MPa Bending Strength Shrinkage (Dried) 0.1% Vertical 8.5 MPa Expansion (Soaked) 0.15% Screw Pullout 70N (9mm thickness) Moisture Content 10% Impact Resistance 1500 J/m 2 ph 10 Thermal Conductivity 0.17 w/mk Fire Resistance When FRAMECAD Fibre Cement is used in conjunction with FRAMECAD Cold Formed Steel Framing there are two very significant advantages. 1. LGS Being non-combustible, when fire burns through the linings it will not spread within the framing cavity in steel framing, whereas this is a major cause of hidden fire spread in timber framing. 2. Steel Framing does not increase the fire load. Timber is combustible and there is at least 20kg of timber per square metre of floor area in a timber framed house. This is 75% of the design fire load of a houses content, which means that a timber framed house is carrying at least 1.75 times the fire load of a steel framed house. The higher the fire load, the more severe the fire. Therefore it is not surprising that fire case histories show steel houses perform very well in house fires, with little or no damage to the framing structure. Furthermore if steel framed members are not visibly distorted they can be left in place, cleaned and if necessary recoated. If they are distorted then they need to be replaced. When FRAMECAD Fibre Cement Sheeting is used for Fire Rated Systems the stud spacing must not exceed 400mm c/c (center to center) and nogs 800mm c/c. Refer to Clause 6.4 in the Fire and Acoustic Design Manual for further guidance on fire rating. The steel framing must be suitably coated to satisfy the Durability requirements of clause B2 of the New Zealand Building Code (NZBC) and other applicable building standards. Item Index Unit Fire Resistance BS 476 Fire test on building materials and structures No failurem at 120 minutes Page 3

7 Storage and Handling It is the responsibility of the builder to ensure that the product meets aesthetic requirements before installation. FRAMECAD will not be responsible for rectifying obvious aesthetic surface variations following installation. FRAMECAD Fibre Cement sheets must be stored flat on a smooth surface. Precaution should be taken that edges and corners are protected from damage. Ensure that all sheets are stored under cover and kept dry. If Sheets become wet they must be dried prior to installation. Carry sheets in the vertical position as this will avoid bending and possible breakage. Page 4

8 Cutting FRAMECAD Fibre Cement Sheets Score and Snap: Score on the face side of the product. Score against a straight edge and repeat the action to obtain adequate depth for a clean break - normally 1/3 of the sheet thickness Snap upwards to achieve the break, smooth any rough edges with a rasp Guillotine: Mark sheet with a straight cut line on the underside of the sheet that is to be cut. Following this line, guillotine cut on the off-cut side of line to allow for the thickness of the blade. Sawing The saw blade used with a dusk reducing saw and vacuum extraction allows for fast, clean cutting for FRAMECAD Fibre Cement sheets. Alternatively, FRAMECAD recommends the use of a wet saw, with a full dust extraction system. When sawing, clamp a straight-edge to the sheet as a guide and run the saws base plate along the straight edge when making the cut. A hand saw offers ability to make small cuts and notches. For accuracy and neatness mark out lines on the face side of the sheet prior to sawing. A quick jabbing motion provides the best result. Forming a Hole: For smooth clean cut circular holes: Mark the center of the hole on the sheet. Pre-drill a pilot hole. Using the pilot hole as a guide, cut the hole to the appropriate diameter with a hole saw fitted to a electric drill. For irregular holes: Small rectangular or circular holes can be cut by drilling a series of small holes around the perimeter of the hole then tapping out the waste piece from sheet face. Tap carefully to avoid damage to sheets, ensuring that the sheet edges are properly supported. Page 5

9 Installation - For Cold Formed Steel Frames FRAMECAD Recommend the following Fastenings to install FRAMECAD Fibre Cement Sheeting. FRAMECAD X-Drive screws are self-embedding ensuring a flush finish SPECIFICATIONS FRAMECAD Part # (Loose) (Loose) (Loose) (Loose) (Loose) Name 10g X Clad Thin 25mm 8g X Clad Thick 5mm 8g X Clad Thick 40mm 8g X Clad Thick 35mm 10g X Clad Thick 45mm Gauge 10g (4.8mm) 8g (4.2mm) 8g (4.2mm) 8g(4.2mm) 10g (4.8mm) Head Type Countersunk (CSK) Countersunk (CSK) Countersunk (CSK) Countersunk (CSK) Countersunk (CSK) Drive Type X Drive #1 X Drive #1 X Drive #1 X Drive #1 X Drive #1 Tip Type Drill Point (DP) Winged Drill Point (WDP) Winged Drill Point (WDP) Winged Drill Point (WDP) Winged Drill Point (WDP) TPI Length (mm) Colour Grey / Green Grey / Green Grey / Green Grey / Green Grey / Green Speed Recommendation (RPM) Coating Class AS Salt Spray Results (hours) ASTM B Kesternich Results (cycles) DIN L For further details on the FRAMECAD Fastening Range please refer to the FRAMECAD Fastenings Catalogue. FRAMECAD Fibre Cement Sheets is typically installed on a C section size of: 89mm x 39mm x 0.75mm/0.95mm/1.5mm/1.55mm When fixing to FRAMECAD C sections fastenings should be fixed as close as possible to the web side of studs to ensure screw engagement. FRAMECAD Fibre Cement Sheets must be placed firmly against the frame when fixing to ensure breakout does not occur on the back. Screw located too far from web, causing bending of flange and a loose fixing of the cladding Screw located close to the web, ensuring a tight fix to the cladding Page 6

10 Fibre Cement Detail - Installation FRAMECAD Cold Formed Steel Wall Frame FRAMECAD Fibre Cement Sheet FRAMECAD X-Drive 35mm Winged Drill Point Screw spacing at 300mm centers FRAMECAD X-Drive 35mm Winged Drill Point Screw positioned 50mm from corners and 12mm from sheet edge Page 7

11 Fibre Cement Detail - Installation FRAMECAD Cold Formed Steel Wall Frame FRAMECAD Fibre Cement Board FRAMECAD X-Drive 35mm Winged Drill Point Screw spacing at 300mm centers FRAMECAD X-Drive 35mm Winged Drill Point Screw positioned 50mm from corners and 12mm from sheet edge Page 8

12 Fibre Cement Detail - Render Jointing System FRAMECAD Fibre Cement Board FRAMECAD X-Drive 35mm Winged Drill Point Screw FRAMECAD Cold Formed Steel Wall Frame FRAMECAD mm Jointing Mesh FRAMECAD Mineral Render System, refer to FRAMECAD Technical Specification for full details about FRAMECAD Minerial Render System FRAMECAD Mineral Render System, refer to FRAMECAD Technical Specification for full details about FRAMECAD Minerial Render System Page 9

13 Fibre Cement - Internal & External Corner Detail FRAMECAD Cold Formed Steel Wall Frame FRAMECAD X-Drive 35mm Winged Drill Point Screw FRAMECAD Mineral Render System, refer to FRAMECAD Technical Specification for full details about FRAMECAD Minerial Render System FRAMECAD Fibre Cement Board FRAMECAD Mineral Render System, refer to FRAMECAD Technical Specification for full details about FRAMECAD Minerial Render System Page 10

14 Fibre Cement Detail - Opening (Door/Window) FRAMECAD X-Drive 35mm Winged Drill Point Screw FRAMECAD Fibre Cement Board FRAMECAD Cold Formed Steel Stud Door / Window Frame Page 12

15 Maintenance Maintenance is the responsibility of the specifier to determine. The extent of any maintenance will be determined by the geographic location and exposure of the building. FRAMECAD recommends the following; Wash exterior surfaces every 6-12 months Reapply paint finish as necessary Ensure all joints, flashings and sealants are maintained to ensure any means of moisture entering beyond the exterior cladding are stopped. Clean gutters and pipes and overflows as needed Prune back vegetation so that it is not touching the cladding Note: FRAMECAD do not recommend the use of a Water Blaster Health and Safety FRAMECAD Fibre Cement Sheeting is manufactured from cement, refined ores and reinforced cellulose fibre. As manufactured the product will not release airborne dust, but during drilling, cutting and sanding operations cellulose fibres, silica and calcium silicate dust may be released. Breathing fine silica dust is hazardous, prolonged exposure (usually over several years) may cause bronchitis, silicosis or cancer. If using power tools for cutting, drilling or sanding they must be fitted with an appropriate dust collection devices and/or used an approved dust mask and wear safety glasses. These precautions are not necessary when stacking, unloading or handling fibre cement products. For further information please contact FRAMECAD Safe Working Practices Do not breathe dust and cut only in well ventilated areas. FRAMECAD Fibre Cement sheets contain and silica which is considered by some authorities as a cause for cancer. Breathing excessive amounts of dust can harm and potentially cause lung disease. Ensure that work is performed in well ventilated areas Reduce dust when cutting by using a score and snap knife or by using a dust reducing saw. Be aware and inform others when cutting is taking place so that they can avoid dust inhalation. Always wear a proper fitting and approved dust mask or respirator. Page 13

16 This document is current as at Dec 2013 and supersedes all previous versions of the FRAMECAD Fibre Cement Technical Guide. The material in this document is provided for general information purposes only. Although all reasonable efforts have been made to ensure that the information is current and accurate as at the date of issue, the information provided is selective and may not be complete or suitable for your intended use or jurisdiction. No information in this document constitutes, or shall be relied upon as constituting, the giving of advice of any nature. Nor is any such information to be used as a substitute for specific advice from appropriate independent professional advisors in your jurisdiction regarding your particular facts and circumstances or as a substitute for compliance with the requirements of applicable regulatory authorities or laws. You should not act (or refrain from acting) based upon information provided by FRAMECAD without independently verifying the original source information and, making your own independent assessment, with the assistance of appropriate independent professional advisors, regarding your particular facts and circumstances. FRAMECAD makes no representation or warranty, express or implied, as to the accuracy, completeness or suitability for purpose, of any information in this document. To the extent permitted by law, FRAMECAD accepts no responsibility to the recipient or any other person for any loss, damage, cost or expense (whether direct or indirect) incurred and arising out of or in connection with any use or reliance by any of them on the information in this document including, but not limited to, as a result of any error, omission or misrepresentation in any information or statement in this document. This limitation of liability includes but is not limited to incidental, special or consequential damages, damages for loss of business or other profits. Liability which cannot legally be excluded is limited to the maximum extent possible. FRAMECAD Ltd, logos and Trademarks are the property of FRAMECAD Ltd. Copyright 2013 FRAMECAD Ltd. Reproduction of any part of this document is prohibited, except with the prior written consent of FRAMECAD Ltd. We have offices here: Auckland, New Zealand (Head Office) Dubai, UAE Dallas, USA Hong Kong Melbourne, Australia Johannesburg, South Africa English - Fibre Cement Sheets 2013

AQUATEC WET AREA FLOORING AUSTRALIA AUGUST 2005 INSTALLATION MANUAL

AQUATEC WET AREA FLOORING AUSTRALIA AUGUST 2005 INSTALLATION MANUAL AQUATEC WET AREA FLOORING AUSTRALIA AUGUST 2005 INSTALLATION MANUAL 1 INTRODUCTION CONTENTS 1 INTRODUCTION 2 2 SAFE WORKING PRACTICES 4 Warning 4 Recommended safe working practices 4 Working instructions

More information

Connection Solutions

Connection Solutions Connection Solutions DESIGN BUILD SYSTEM Connection Solutions for Cold formed Steel Construction Complies with; AS/NZS 4600:2005 AISI S100:2007 AS/NZ 1397 ASTM A653 DESIGN & BUILD SYSTEM FRAMECAD Construction

More information

BETONYP building boards. The modern way of living.

BETONYP building boards. The modern way of living. BETONYP building boards The modern way of living. Tough for 30 years. Healthy, debarked pine wood and cement: the raw materials used to produce one of our most successful products for more than three decades.

More information

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for premium composite, hollow and solid core molded Bifold Doors. Bifolds are designed for fast

More information

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap Tile Backing Will not deteriorate in water Easy to score and snap Resistant to mould and mildew Knauf Aquapanel Interior Cement board for wet areas Knauf Aquapanel Interior Cement Board Drywall for Wet

More information

FC:121 EXTERNAL CLADDING & EAVES LINING CSR CEMINTEL

FC:121 EXTERNAL CLADDING & EAVES LINING CSR CEMINTEL CSR CEMINTEL EXTERNAL CLADDING & EAVES LINING EXTERIOR CLADDING SYSTEM A fast, simple, durable and attractive external cladding system for residential walls, ceilings and eaves. FC:121 SEPTEMBER 2013 2

More information

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas Powerpanel H 2 O is a cement based board from FERMACELL. Board Characteristics Board Thickness 12.5 mm Board Sizes 1000 x 1200 mm 50 sheets/pallet

More information

Window Installation Instructions

Window Installation Instructions Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for

More information

OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. GeneralShale.com

OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. GeneralShale.com OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide GeneralShale.com OLD BRICK ORIGINALS THIN BRICK VENEER Page 2 INTRODUCTION Check local building codes for proper installation guidelines

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

Fiberglas, Exterior Wall Thermal Insulation

Fiberglas, Exterior Wall Thermal Insulation PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.

More information

Mold Preventing I nterior System

Mold Preventing I nterior System interior insulation and renovation boards A system of components that have been designed to work perfectly together to repair damage caused by mold. The system consists of boards, insulation wedges, reveal

More information

IMPACT DAMAGE RESISTANT WALL SYSTEMS

IMPACT DAMAGE RESISTANT WALL SYSTEMS IMPACT DAMAGE RESISTANT WALL SYSTEMS CONTENTS Introduction 2 Advantages 2 2 Material Specifications 2 Design Considerations 3 Framing 5 Plasterboard Installation 5 Health, Safety & Warranty 6 Contact Details

More information

Standard from CSI Part Section Format. 06212 For Wood Framing 05160 For Metal Framing 09226 For Gypsum Sheathing

Standard from CSI Part Section Format. 06212 For Wood Framing 05160 For Metal Framing 09226 For Gypsum Sheathing Standard from CSI Part Section Format. 06212 For Wood Framing 05160 For Metal Framing 09226 For Gypsum Sheathing Specifications for SURE-BOARD Series 200 and 200W Panel for shear PART 1.0 GENERAL 1.01

More information

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

NRG 75 CRF NRG GREENBOARD WALL SYSTEM NRG GREENBOARD WALL SYSTEM NRG Energy Efficient Building Systems is pleased to announce a revolution in lightweight cladding systems. NRG Building Systems is the first and only company to achieve CodeMark

More information

GYPSUM AREA SEPARATION FIREWALLS GA-620-2011

GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GA-620-2011 Copyright 2011 Gypsum Association All rights reserved. Printed in U.S.A. Characteristics, properties, or performance of materials or systems herein

More information

PANELIZED HOME INSTALLATION GUIDELINE

PANELIZED HOME INSTALLATION GUIDELINE PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.

More information

Clad Direct Glaze Window Installation Instructions

Clad Direct Glaze Window Installation Instructions Clad Direct Glaze Window Installation Instructions Sill flashing and sealing: 2. An overview of the proper flashing sequence is shown in figure 1. Please read entire installation instructions carefully

More information

Steel-framed Walls. Insulation

Steel-framed Walls. Insulation Insulation A4/8 SF AW1192 Issue 4 Nov 2012 Steel-framed Walls Insulation guide Helps achieve a 6-star house energy rating Rigid and flexible Kingspan AIR-CELL solutions available Vapour barrier or vapourpermeable

More information

Composite Stone Veneer

Composite Stone Veneer Composite Stone Veneer Installation Guide Ver 1 Jun 2015 www.compstone.com Composite Stone Veneer Installation Guide Contents Introduction & Overview 3 Required Tools 4 Optional Tools 4 Attachment Guidelines:

More information

application instructions

application instructions application instructions ARCHITECTURAL COLLECTION PRIMED BOLD PROFILE 120 SERIES LAP SIDING (D5, T4, D8, T5, Q4) General At the time of manufacture, siding meets or exceeds the performance standards set

More information

KEEP ASBESTOS YOUR QUICK GUIDE DON T BE AN EASY TARGET THIS GUIDE

KEEP ASBESTOS YOUR QUICK GUIDE DON T BE AN EASY TARGET THIS GUIDE KEEP THIS GUIDE ASBESTOS YOUR QUICK GUIDE DON T BE AN EASY TARGET Asbestos could be in the house or building you are working on right now. Left alone, it isn t dangerous. However, once disturbed, tiny

More information

Installing Window and Door Mouldings

Installing Window and Door Mouldings Installing Window and Door Mouldings About Window and Door Mouldings The trim around windows and doors greatly influences the look and style of your interior. They also bridge the gaps and cover spaces

More information

The WANZ Guide to Window Installation

The WANZ Guide to Window Installation The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 Ver. 1.1 Page 2 of 74 Contents Overview Page 5 Objective Page 5 Scope Page 5 Opening Preparation Page 7 Step P1 Preliminary Check

More information

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING IMPORTANT NOTICES AND INFORMATION Read these instructions in their entirety prior to installing windows. Any local building code requirements

More information

Regulatory Services. Asbestos in the Home. What is asbestos?

Regulatory Services. Asbestos in the Home. What is asbestos? Regulatory Services Asbestos in the Home What is asbestos? Asbestos is a natural silicate mineral consisting of fibres. The fibres are strong, durable, and resistant to heat, long, thin and flexible. There

More information

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW Vinyl Windows and Doors Manufactured by Pella Corporation INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW Lea las instrucciones en español en el reverso.

More information

GreenGuard Housewrap Installation Guide

GreenGuard Housewrap Installation Guide 000768PACBPHW_Flashing Bro 5/23/03 2:52 PM Page 1 For the most current product information, go to www.green-guard.com. Pactiv Building Products believes the information and recommendations herein to be

More information

ULTIMATE GUIDE BE PREPARED FOR YOUR UPCOMING PROJECT

ULTIMATE GUIDE BE PREPARED FOR YOUR UPCOMING PROJECT ULTIMATE GUIDE BE PREPARED FOR YOUR UPCOMING PROJECT What are Backer Boards and Underlayments? Backer boards and underlayments are used on interior walls, floors and countertops to provide a uniform surface

More information

K2 STONE NATURAL VENEER

K2 STONE NATURAL VENEER INTRODUCTION WHAT IS K2 NATURAL THINSTONE VENEER? Natural K2 Stone veneer is real stone, cut 1 inch thick, making it light enough to be installed as a veneer. Sometimes referred to as thin veneer, thin

More information

CEILING SYSTEMS. CI/SfB (35) Xy April 2006. [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design

CEILING SYSTEMS. CI/SfB (35) Xy April 2006. [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design CEILING SYSTEMS [Between us, ideas become reality.] CI/SfB (35) Xy April 2006 ULTIMA CANOPY Data sheet Acoustic performance meets High Design ULTIMA CANOPY Installation Instructions I. GENERAL 1. Product

More information

Shingle Installation Guide

Shingle Installation Guide Shingle Installation Guide Getting Started Dedicated to improving the environment, NewTech manufactures roofing tiles that are composed of up to 90% recycled post-industrial plastic. The manufacture of

More information

Sun Windows General Information Sun New Construction Window Installation Instructions

Sun Windows General Information Sun New Construction Window Installation Instructions Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten

More information

SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system

More information

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Services Enclosures and Protected Shafts - Maintaining Compartmentation Introduction When a fire resisting element is used to provide fire compartmentation, every opening that allows services to pass through the element must be adequately protected by sealing, or fire stopping

More information

Please calculate with around 5% more square meters than needed because you will have material loss due to cutting and sorting.

Please calculate with around 5% more square meters than needed because you will have material loss due to cutting and sorting. 1. TEKA Soft Loc Installation Guide Thank you for having chosen TEKA Parquet. To guarantee a constant quality product TEKA engineered hardwood flooring is made out of selected wood species and runs only

More information

LAYING BLOCK AND BRICK

LAYING BLOCK AND BRICK LAYING BLOCK AND BRICK Products highlighted in this section: SAKRETE Type N Mortar Mix SAKRETE Type S Mortar Mix Brick And Block Laying Basics The first step in building a brick or block wall is to construct

More information

IN00378 (rev A) Corner Entry

IN00378 (rev A) Corner Entry IN00378 (rev A) Corner Entry Before You Start Check that the tray has been installed correctly and that it is level (Fig. A), tiled down onto and sealed to the manufacturer s guidelines. Please Note: All

More information

GigaCrete Specification PlasterMax

GigaCrete Specification PlasterMax GigaCrete Inc. 6775 Speedway Blvd. Suite M105 Las Vegas, NV 89115 Ph (702) 643-6363 Fax (702) 643 1453 www.gigacrete.com GigaCrete Specification PlasterMax PlasterMax : Fire Rated Plaster for Direct Application

More information

Product Guide Specification

Product Guide Specification Stabilit America, Inc., dba Glasteel June 2005 285 Industrial Drive Moscow, Tennessee 38057 Toll Free (800) 238-5546 Phone (901) 877-3010 Fax (901) 877-1388 Web Site www.glasteel.com Product Guide Specification

More information

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders

More information

REDI-EXIT COMMERCIAL FIRE DOOR AND EXTERIOR DOOR KITS INSTALLATION GUIDELINES

REDI-EXIT COMMERCIAL FIRE DOOR AND EXTERIOR DOOR KITS INSTALLATION GUIDELINES REDI-EXIT COMMERCIAL FIRE DOOR AND EXTERIOR DOOR KITS INSTALLATION GUIDELINES Tools Required Tape Measure Hammer Slotted Screw Driver #2 & #3 Philips Screw Driver 3-4 Foot Level 12 Pry Bar Cold Chisel

More information

Brick Veneer Construction

Brick Veneer Construction Brick Veneer Construction Check list of suggested tools & support items Claw hammer Tape measure 3/4" [19 or 20] Wood chisel Wood or plastic shims Pry bar Utility knife Caulking and caulking gun Power

More information

2015 DuROCK Alfacing International Limited

2015 DuROCK Alfacing International Limited SEPTEMBER 2015 DuROCK DEFS Direct-Applied Exterior Finish System MANUFACTURER S IFICATION 09 25 15 Part 1 GENERAL 1.1 RELATED SECTIONS.1 Specification 03 30 00 Cast-in-Place Concrete.2 Specification 04

More information

CertainTeed. Shaftliner For A rea Separation Firewalls

CertainTeed. Shaftliner For A rea Separation Firewalls CertainTeed Shaftliner For A rea Separation Firewalls M2Tech Shaftliner Type X for Area Separation M2Tech Shaftliner is a specially formulated product for applications where enhanced mold resistance is

More information

Wet Area Construction. Carpentry - Residential Construction. Product Code: 5603

Wet Area Construction. Carpentry - Residential Construction. Product Code: 5603 E PL SA M Wet Area Construction Carpentry - Residential Construction Product Code: 5603 Publishing details: Second Edition 2012 TAFE NSW Training and Education Support, Industry Skills Unit Orange and

More information

TECHNICAL BULLETIN TECHNICAL DESCRIPTION DESCRIPTION OVERVIEW PROGRAMS. Data Sheet. Pilkington Toughened Safety Glass

TECHNICAL BULLETIN TECHNICAL DESCRIPTION DESCRIPTION OVERVIEW PROGRAMS. Data Sheet. Pilkington Toughened Safety Glass Data Sheet Pilkington Toughened Safety Glass Introduction Pilkington has manufactured and marketed toughened glass for over 60 years. Its properties and performance have been proven in countless applications,

More information

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work. Installation Guide Before you begin, take the time to read this entire guide to clearly understand the requirements and steps to follow for proper installation. Warning Do not install defective material.

More information

How to Build Your Own CornHole Game

How to Build Your Own CornHole Game How to Build Your Own CornHole Game DIMENSIONS Here is a diagram with the basic measurements for the Cornhole board game. SUPPLIES 1/2 thick sheet of plywood one 4 x4 or two 2 x4 s 8 long 2 4 s (4) 4 1/2

More information

1.2.1 1.1.8 PRODUCTBLADEN GT ROCKPANEL STRUCTURE

1.2.1 1.1.8 PRODUCTBLADEN GT ROCKPANEL STRUCTURE 1..1 1.1.8 PRODUCTBLADEN SHEETS GT page 1 to 6 Rockpanel Structure is a very durable panel with a lightly textured finish, specially developed for use in cladding, fascia, soffit applications. The basic

More information

Façade panels for interior cladding on a wooden supporting structure

Façade panels for interior cladding on a wooden supporting structure 1 General These application instructions are specifically intended for the fastening of EURO PANELS OVERSEAS N.V. façade panels as decorative interior wall cladding on a wooden supporting structure. A

More information

Installation Instructions

Installation Instructions Installation Instructions Pedestal Models FS 500 LE FS 800 LE Insert Models IS 500 LE IS 800 LE Pecan Engineering Pty Ltd 13 Acorn Road Dry Creek South Australia 5094 Email info@pecan-eng.com.au Phone:

More information

PRODUCT & INSTALLATION GUIDE PREVENTS

PRODUCT & INSTALLATION GUIDE PREVENTS CEMENT BACKERBOARD FOR TILE AND STONE PRODUCT & INSTALLATION GUIDE PREVENTS MOISTURE DAMAGE MOULD GROWTH & TILE FAILURE DO IT ONCE, DO IT RIGHT. TM What is Cement Backerboard? HardieBacker is a cement

More information

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles INSTALLATION RECOMMENDATIONS Outdoor Rubber Tiles Prior to Installation: The Outdoor Rubber Tiles and accessory transition pieces intended for this installation have been shipped to you via a freight carrier

More information

Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows

Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows Viewed from the exterior. IMPORTANT: Please read before you begin installation. TABLE OF CONTENTS AND TOOL / MATERIAL

More information

DECKING INSTALLATION, CARE & MAINTENANCE INSTRUCTIONS. 866.729.2378 MOISTURESHIELD.COM limited lifetime warranty 866.729.2378 WWW.MOISTURESHIELD.

DECKING INSTALLATION, CARE & MAINTENANCE INSTRUCTIONS. 866.729.2378 MOISTURESHIELD.COM limited lifetime warranty 866.729.2378 WWW.MOISTURESHIELD. DECKING INSTALLATION, CARE & MAINTENANCE INSTRUCTIONS 866.729.2378 MOISTURESHIELD.COM limited lifetime warranty Welcome To The Even Greater Outdoors. Congratulations on choosing MoistureShield for your

More information

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS

More information

Manual lifting and handling

Manual lifting and handling Manual lifting and handling When installing British Gypsum products and systems care should be taken to ensure that appropriate methods of handling and lifting are adopted. The following guidance details

More information

How to Install GoBoard:

How to Install GoBoard: How to Install GoBoard: A Step-by-Step Guide Durable, Ultra-Lightweight, Waterproof Tile Backer Board Introducing GoBoard Every tiling project requires a durable, waterproof surface under the tile, called

More information

Basement Window Installation Guide Hopper and Sliding

Basement Window Installation Guide Hopper and Sliding Basement Window Installation Guide Hopper and Sliding americancraftsmanwindows.com Project Requirements: Installation must comply with all applicable building codes. Existing window frame, wall and weatherresistant

More information

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally

More information

TEST REPORT. Report No.: A9814.01 109 44. Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

TEST REPORT. Report No.: A9814.01 109 44. Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept Architectural Testing TEST REPORT Report No.: A9814.01 109 44 Rendered to: BAMCO INC. Middlesex, New Jersey PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept AAMA 508 07, Voluntary Test Method

More information

Gate Leg Drop Leaf Table Plans

Gate Leg Drop Leaf Table Plans Preparing the table top blanks: Cut and glue enough 3/4 stock to make three panels 40 long by 24 wide (they will be cut to final size at a later time). While the glue dries we will work on the legs. Preparing

More information

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests Product Data Sheet Edition 05/12/2014 Identification no: 020204030010000044 Sikadur -41 CF Rapid 3-part thixotropic epoxy patching mortar Construction Product Description Uses Characteristics / Advantages

More information

BENTLEY ELEMENTS COLLECTION LVT

BENTLEY ELEMENTS COLLECTION LVT This document refers to the following products: Product Size Installation direction Seams treatment Elements Tiles See specifications 90 None Elements Planks See specifications Stair Step None Note: This

More information

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render BEST PRACTICE GUIDE Fibrelime Premixed Universal Plaster and Render Contents: Fibrelime description Fibrelime suitability Preparation before application Application Aftercare Painting General Recommended

More information

managing asbestos in church buildings

managing asbestos in church buildings managing asbestos in church buildings A joint briefing paper produced by Church Growth Trust and Stewardship April 2013 Briefing Paper 1 Lamb s Passage, London EC1Y 8AB t: 020 8502 5600 e: enquiries@stewardship.org.uk

More information

INSTRUCTION FOR ASSEMBLY. 150x180 v Traditional sauna cabin

INSTRUCTION FOR ASSEMBLY. 150x180 v Traditional sauna cabin INSTRUCTION FOR ASSEMBLY 150x180 v Traditional sauna cabin 1. SAUNA PLAN 1800 LIGHT UNDER THE BENCH VENTILATION OUTLET UPPER BENCH 600 1500 LOWER BENCH 400 700 1656 956 HEATER 366 381 690 815 Light switch

More information

HfHMD uses LP SmartSide siding and trim.

HfHMD uses LP SmartSide siding and trim. HfHMD uses LP SmartSide siding and trim. These products are: More durable than cement fiber board. Much more volunteer-friendly to install. When installed correctly, have a 5/50- year pro-rated warranty.

More information

LEGACY REPORT. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council. *Corrected March 2014

LEGACY REPORT. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council. *Corrected March 2014 ICC-ES Legacy Report PFC-3700* Issued October 2003 www.icc-es.org (00) 423-57 (52) 99-0543 A Subsidiary of the International Code Council Legacy report on the 1997 Uniform Building Code and the 2000 International

More information

WOLVERHAMPTON WASTE SERVICES GUIDANCE FOR THE SAFE REMOVAL, COLLECTION AND DISPOSAL OF MATERIALS CONTAINING ASBESTOS OR ASBESTOS CEMENT

WOLVERHAMPTON WASTE SERVICES GUIDANCE FOR THE SAFE REMOVAL, COLLECTION AND DISPOSAL OF MATERIALS CONTAINING ASBESTOS OR ASBESTOS CEMENT WOLVERHAMPTON WASTE SERVICES GUIDANCE FOR THE SAFE REMOVAL, COLLECTION AND DISPOSAL OF MATERIALS CONTAINING ASBESTOS OR ASBESTOS CEMENT IMPORTANT PLEASE ENSURE THAT YOU READ AND UNDERSTAND THE GUIDANCE

More information

Introduction...COMB-2 Design Considerations and Examples...COMB-3

Introduction...COMB-2 Design Considerations and Examples...COMB-3 SECTION DIRECTORY General Information Introduction...COMB-2 Design Considerations and Examples...COMB-3 Combination Assembly Recommendations and Limitations Composite Configurations...COMB-4 Typical Sealant

More information

Facade systems. Technical specification. ComTex facade panel and fixing system

Facade systems. Technical specification. ComTex facade panel and fixing system Facade systems Technical specification ComTex facade panel and fixing system AUSTRALIA FEBRUARY 2015 CONTENTS 1 INTRODUCTION 2 1.1 Application 2 1.2 Factors to be considered 3 1.3 Levels of finish 3 1.4

More information

INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS

INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS 2009 Pella Corporation INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS Part Number: 80WH0100 Installation Instructions for Typical Wood Frame Construction.

More information

Composite Panel Firewall Systems

Composite Panel Firewall Systems Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.

More information

Owner's Manual & Assembly Instructions

Owner's Manual & Assembly Instructions Owner's Manual & Assembly Instructions PM01 BASE KIT Model No. FDN1014 717090311 CAUTION: SOME PARTS HAVE SHARP EDGES. CARE MUST BE TAKEN WHEN HANDLING THE VARIOUS PIECES TO AVOID A MISHAP. FOR SAFETY

More information

FC:533 CONSTRUCTAFLOOR WET AREA FLOORING CEMINTEL RESIDENTIAL INTERNAL WET AREA FLOORING SYSTEM

FC:533 CONSTRUCTAFLOOR WET AREA FLOORING CEMINTEL RESIDENTIAL INTERNAL WET AREA FLOORING SYSTEM CEMINTEL CONSTRUCTAFLOOR WET AREA FLOORING FC:533 RESIDENTIAL INTERNAL WET AREA FLOORING SYSTEM MARCH 2015 Constructafloor Wet Area flooring is an advanced, lightweight, fibre cement flooring that offers

More information

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035 Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí

More information

SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING

SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING PART ONE GENERAL DESCRIPTION This section includes pre-formed standing seam metal roofing and related flashings, closures, trim and accessories including,

More information

Barewood Octagon and Elongated Windows Installation Instructions

Barewood Octagon and Elongated Windows Installation Instructions Step-by-step instructions to a beautiful window. Measuring and Installation of your new window from Century Specialty Windows couldn't be easier with our step-by-step instructions. Quality, function and

More information

These instructions will show you how to install an internal door into a non-loadbearing partition wall. The instructions are split into three parts.

These instructions will show you how to install an internal door into a non-loadbearing partition wall. The instructions are split into three parts. No 8 in the series of 'How to' brochures produced by PlaceMakers, New Zealand How to Frame and Hang a Door These instructions will show you how to install an internal door into a non-loadbearing partition

More information

AA Solar and Sun Power Plus

AA Solar and Sun Power Plus AA Solar and Sun Power Plus www.aasolar.co.nz www.sunpowerplus.co.nz -1- Contents Chapter Title Page 1 General information 3 2 Safety and Installer Responsibilities 4 3 Technical Specifications 5 4 Tools

More information

HOW-TO LAY HARDBOARD OR PLYWOOD FLOOR OVERLAY

HOW-TO LAY HARDBOARD OR PLYWOOD FLOOR OVERLAY HOW-TO HOW-TO LAY HARDBOARD OR PLYWOOD FLOOR OVERLAY Most floor coverings, if laid over uneven wooden floors, will wear unevenly and look unsightly. The answer is to cover the old boards with hardboard

More information

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3

More information

www.cornholesupplies.com

www.cornholesupplies.com www.cornholesupplies.com How To Build Regulation Cornhole Boards Home of the Original Cornhole Bags and Boards Supply List: 1-4' X 8' Piece of Plywood (pre sanded) 4-2" X 4" X 8' Studs (2 by 4s make sure

More information

Enclosures 1-866-338-0988. DuraSystems Barriers, Inc. www.durasystems.com Email: sales@durasystems.com. The Passive Fire Protection Specialists

Enclosures 1-866-338-0988. DuraSystems Barriers, Inc. www.durasystems.com Email: sales@durasystems.com. The Passive Fire Protection Specialists Enclosures Sturdy single and double wall fire protection construction Impact resistant Fast & easy installation Pre-manufactured and modular Available in galvanized, stainless steel & other specialty metals

More information

Eucaboard / Eucaplac/ Eucatile paneling is intended for dry interior use only and requires care in handling.

Eucaboard / Eucaplac/ Eucatile paneling is intended for dry interior use only and requires care in handling. i This instruction sheet describes the proper methods for installing Eucatex decorative wall paneling. Eucaboard / Eucaplac/ Eucatile paneling is intended for dry interior use only and requires care in

More information

Asbestos in your home

Asbestos in your home Asbestos in your home How to dispose of Asbestos safely Telephone Number: 01372 732000 contactus@epsom-ewell.gov.uk www.epsom-ewell.gov.uk If you would like a copy of this document in large print, on tape

More information

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS NOISE TECHNICAL FACT SHEET FACT SHEET 5 SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS The sound insulation of exterior walls and roof-ceiling systems refers to their ability to reduce external

More information

HVAC Vents & Diffusers

HVAC Vents & Diffusers 2 HVAC Vents & Diffusers Drywall, Stone, & Wood Applications TRUFIG can be installed in a variety of finishes and surfaces. This guide will detail the install of HVAC vents and diffusers in drywall, stone,

More information

STENCA PIPE. High quality pipe insulation. www.stenca.com

STENCA PIPE. High quality pipe insulation. www.stenca.com STENCA PIPE High quality pipe insulation WELCOME TO STENCA TRADING - Global focus with local service Stenca Trading offers optimal solutions for the offshore, marine, refineries and cogeneration industry.

More information

ASBESTOS AND THE HOME RENOVATOR. A basic guide on what you need to know about asbestos

ASBESTOS AND THE HOME RENOVATOR. A basic guide on what you need to know about asbestos ASBESTOS AND THE HOME RENOVATOR A basic guide on what you need to know about asbestos DISCLAIMER This publication contains information regarding occupational health and safety. It includes some of your

More information

Shower Walls and Tub Surrounds

Shower Walls and Tub Surrounds Reverso en español TEC Skill Set How-To Project Guide Shower Walls and Tub Surrounds 3 Steps to a Beautiful Tile Surface! 1. Prepare the surface 2. Set the tile 3. Grout and caulk H.B. Fuller Construction

More information

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa Profiles in stock Standard catalogue Discover the possibilities with aluminium from Sapa You can create your own profile or you can choose from a wide selection of standard. Delivery: 1 2 weeks for standard

More information

March 14, 2007. Installation of Bay, Bow and Garden Windows

March 14, 2007. Installation of Bay, Bow and Garden Windows March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed

More information

Submittal Sheet. Product: Item# Description Unit Pack

Submittal Sheet. Product: Item# Description Unit Pack Submittal Sheet Submittal Sheet #03090414-H Hex Head Drivall Screws (246) Product: Item# Description Unit Pack 08050H3 8 x 1/2-in, Hex Head, Drivall, Clear Zinc, Bulk 10,000 12150H3RG 12 x 1-1/2-in, Hex

More information

EcoTouch Insulation with PureFiber Technology

EcoTouch Insulation with PureFiber Technology PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.

More information

H-Stud Area Separation Wall System

H-Stud Area Separation Wall System 12 TH EDITION 09 21 16.33/NGC H-Stud Area Separation Wall System 09 21 16.33 139 H-STUD AREA SEPARATION WALL SYSTEM The fire-protection of gypsum-based Area Separation Walls is demonstrated in dramatic

More information

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork HVAC - Fire protection of metal ductwork Fire protection Thermal insulation Isover ULTIMATE TM Protect - Fire protection

More information