1 8 Inclined pressure reducing s opyright 0 aleffi H Series Installation, commissioning and servicing instructions Function Pressure reducing s are installed in residential water systems to reduce and stabilise inlet pressure from the water mains supply which is generally too high and variable for domestic appliances to function properly. These s can also be used to control inlet pressure to domestic hot water storage and in hot water applications. The aleffi H series have been specifically designed and manufactured to meet the requirements of S7.:00 Valves primarily for use in warm and hot water systems - P. : ontrol s. Product range S 7. of 067 Series H US Pressure reducing N (/ ), N 0 (/ ) N ( ) Female connections (ISO 7/) ode 0H US -way pressure reducing N 0 (/ ) Female connections (ISO 7/) ode H US -way pressure reducing N 0 (/ ) Female connections (ISO 7/) Technical specifications Materials: ody: over: ontrol spindle: artridge: omponents: iaphragm: Seals: Strainer: Plug ( way model): dezincification resistant alloy R N 6 W60N P6G0 stainless steel POM brass N 6 W67N PM PM stainless steel PPG0 Performance: Pressure setting range: kpa; 00 kpa (code H US) Factory setting: 00 kpa Max. inlet pressure: 000 kpa Max. working temperature: 80 Medium: water omplies with: S 7.
2 S 7. WMK 067 Series Pressure range: kpa Max inlet pressure 600 kpa Flow rate: 00 kpa 600 kpa Max temperature: 60 imensions S 7. WMK067 Series Pressurerange: kPa Maxinletpressure600kPa Flowrate: 00kPa 600kPa Maxtemperature: 60 ode H H 6H / / 7, 7, Ø 6 Ø 6 Mass (kg) 79 0, 8, 0,6 7, Ø 6 9 0, Pressure drop diagram Under following conditions: - Inlet pressure: 800 kpa - Outlet set pressure: 00 kpa p (kpa) / / p (m w.g.) N 0 0, 0, 0 Flow rate (S 7.): N N 0 N 0 l/min 0 l/min 0 00 kpa 70 l/min 0 l/min 0 00 kpa 7 l/min l/min 600 kpa 0 0 Flow rate (l/min) (m /h) S 7. WMK067 Series Pressurerange: kPa Maxinletpressure600kPa Flowrate: 00kPa 600kPa Maxtemperature: 60 p (kpa) / p (m w.g.) ode N 0H 0 / 7, 0 Ø 6 8, Mass (kg) 0,9 0 0, Flow rate (S 7.): N kpa 0 00 kpa 600 kpa 0, Flow rate (l/min) (m /h) p (kpa) / p (m w.g.) , 0, Flow rate (l/min) (m /h) ode H N 0 / 67 6 Ø 6 Mass (kg) 0,9 Flow rate (S 7.): N kpa
3 Installation The pressure reducing must be installed by a licensed plumber and in accordance with S/NZS 00, relevant local requirements and following these instructions. heck Pressure reducing Line strainer (where fitted) Isolating MINS SUPPLY Pressure reducing Line strainer (where fitted) Isolating MINS SUPPLY heck Straight outlet ngle outlet Inlet Outlet Inlet Plug Plug Outlet System without recirculation STORG HOT WTR HTR Tempering OL WTR INLT
4 . Flush the system.. Install the pressure reducing in any position either vertically or horizontally, not upside down, paying attention to the direction of flow indicator on the body of the.. aleffi H series pressure reducing s are factory set at 00 kpa.. If required, reset the pressure by turning the screw on the top of the plastic cover. Turn it clockwise to increase the pressure and anticlockwise to decrease it. Note: code H has fixed setting, not adjustable. Recommendations for installation. Installation below ground If installing the H series underground, please ensure that steps are taken to protect the from becoming frozen in frost-prone areas. Please allow yourself sufficient space to remove the cartridge should maintenance be required. The reading of a gauge for setting purposes may be difficult and an alternate means of checking downstream pressure may ne necessary.. Water hammering This is one of the main problems which may affect pressure reducing s. It is best to fit special devices to absorb water hammering when fitting pressure reducing s in systems at risk. WRNING: If it is critical to maintain the downstream pressure setting to protect equipment, as a safety measure, we recommend that a pressure, or safety, relief is installed downstream of the pressure reducing. Trouble-shooting. Increased downstream pressure near a water heater This problem is due to the water being heated by the water heater. There is no relief of the pressure because the reducing is correctly closed. The solution is to install an expansion vessel (between the heater and the reducer) to absorb the pressure increase.. The pressure reducing does not maintain its set pressure In most cases this is the result of impurities that deposit on the seat causing leakage with a resulting increase in pressure downstream. The solution is to fit a filter upstream from the reducer and subsequently to maintain and clean the cartridge (see Maintenance).
5 Maintenance Proceed as follows for periodic cleaning of the strainer and inspection of the cartridge: Turn off upstream water supply to the pressure reducing and open an outlet downstream to relief pressure Unscrew (anticlockwise) the setting screw to decompress the spring inside. Unscrew the cover. xtract the cartridge with the aid of pincers to grip the head of the screw. fter inspection and cleaning, refit the cartridge or, alternatively, fit a replacement cartridge. 6 Reset the (see Installation). Safety If the pressure reducing is not installed, commissioned and maintained properly in accordance with the instructions contained in this manual, it may not operate correctly, and may cause damage to objects and/or persons. Make sure that all the connections are water-tight. When installing the pressure reducing, make sure not to over-tighten the connections to the as, over time, a failure can occur with subsequent water leakage causing damage. In the case of highly aggressive water, arrangements must be made to treat the water before it enters the pressure reducing, in accordance with current legislation. Otherwise, the pressure reducing may be damaged and not function correctly. Leave this operating manual with the user
6 USTRLIN GNT ll Valve Industries Unit, 8-8 Sir Joseph anks rive Kurnell NSW Ph: (0) 8 98 Fax: (0) 8 98 mail: info@all.com.au LFFI S.R. 9, n. 800 Fontaneto d gogna (NO) Italy Tel. Int R.. Fax mail:info@caleffi.com
series 5350 5351 Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN 12165 CW617N
Pre-adjustable pressure reducing valves with self-contained cartridge - series CCREDITED ISO 9 FM ISO 9 No. CLEFFI / GB replaces / GB Function Pressure reducing valves are devices which, when installed
More informationSTABITHERM INSTALLATION & SERVICE BOOKLET
STABITHERM INSTALLATION & SERVICE BOOKLET TABLE OF CONTENTS Introduction...3 Warranty...3 Product Range and Physical Description...4 Method of Operation...5 Recommended Pressures and Temperatures...6 Flow
More informationCALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB
Compact automatic flow rate regulator with polymer cartridge 127 series REGISTERED BS EN ISO 9001:2000 Cert. n FM 21654 UNI EN ISO 9001:2000 Cert. n 0003 CALEFFI 01166/09 GB Function The AUTOFLOW devices
More information2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications
Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?
More informationCoolflo Safe Touch Shower Mixing Valve ST20015CP
Coolflo Safe Touch Shower Mixing Valve ST20015CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept
More informationDN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing
Technical data sheet R5.. Characterized control valves, 3-way, with external thread for open and closed cold and warm water systems for modulating control on the water side of air-handling and heating
More informationAIR LINE VALVES AND GAUGES
AIR LINE VALVES AND GAUGES INGERSOLL-RAND AIR LINE VALVES AND GAUGES Maintaining consistent air pressure throughout the entire system is crucial for maximum performance and productivity. Ingersoll-Rand
More informationFloat and Thermostatic Traps Series H, C and X
Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT
More informationPRESSURE REDUCING VALVES
0E0-GB PRESSURE REDUCING VAVES MAIN FEATURES The pressure reducing valve is able, by varying its pressure drops, to hold the downstream pressure of the fluid at a constant level against changes in the
More informationInstallation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet
More informationZenith Solar thermal 4.5m pump station Installation manual
Zenith Solar thermal 4.5m pump station Installation manual Product code: 20026145 INSTALLATION MANUAL WATER RETURN GROUP This instruction manual is an integral part of the installation and maintenance
More informationThermostatic bar showers. Troubleshooting and maintenance
Thermostatic bar showers Troubleshooting and maintenance General Fault Diagnosis Outlet too cold Outlet too hot - Hot water supply must be 10ºC higher than desired mixed outlet for the mixer to operate
More informationOverview of types. Technical data
Technical data sheet R3..xx-S.. Characterised control valves, 3-way, with internal thread For closed cold and warm water systems For modulating water-side control of HU and heating systems ir bubble-tight
More informationAURORA. 1030 AND 1040 Series SUCTION DIFFUSERS, COMBINATION AND TRIPLE DUTY VALVES WWW.AURORAPUMP.COM
UROR 1030 ND 1040 Series SUCTION DIFFUSERS, COMINTION ND TRIPLE DUTY VLVES WWW.URORPUMP.COM UROR 1030 ND 1040 Series Suction Diffusers, Combination and Triple Duty Valves Designed for Direct Mounting on
More informationAssisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
More informationPRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM
PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM PRESSURE REDUCER AND RELIEF VALVES These devices are used to reduce and control a gaseous flow pressure (air, steam, gas ). The PRESSURE
More informationSpeedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual
Speedflow Undersink Unvented Water Heater Models SF10K and SF15K Instruction Manual Version 2.0 May 2009 Hyco SpeedFLOW UnVENTED WATER HEATER Models SF10K (10 Litres) and SF15K (15 Litres) 1. Introduction
More informationType overview. Technical data
Technical data sheet R3..xx-S.. Characterised control valve, 3-way, Internal thread For closed cold and warm water systems For modulating water-side control of air handling units and heating systems ir
More informationPressure reducing valves. Guide of applications
Pressure reducing valves Guide of applications CONTENTS 2 page The pressure reducing valve : Definition 3 Water savings 3 Pressure reducing valves or Regulators? 3 WATTS, the inventor of the regulator
More informationLEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34
LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34 2 LEVEL GAUGES WITH MAGNETIC JOINT SIZE Ø 140/220/340 58 58 TYPE LA TYPE LA 14 30 S 22 33 TYPE LA 22-34 NO. HOLES Ø D2 76 O-RING CENTRE OF THE CONSERVATOR
More informationOperators manual Basic water heater
Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,
More informationTHERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494
THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494 1. BEFORE YOU BEGIN IMPORTANT INSTRUCTIONS READ AND SAVE FOR THE CONSUMER WARNING: Risk of scalding or other severe injury. Before completing installation,
More informationSeated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange
Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications. The
More informationYour safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
More informationAquamax Australia Pty Ltd ABN 17 138 189 689
Aquamax Australia Pty Ltd ABN 17 138 189 689 AQUAMAX SERVICE MANUAL Stainless Steel Electric Water Heaters AQ0903010-A Revision: A Published: November 2012 E80 to E315 Series Contents Introduction... 3
More informationSELECTION, APPLICATION AND MAINTENANCE
DIESEL PROTECTION SYSTEMS D-Series Engine Automatic Overspeed Shut Down Valves (Spindle Types with Air Pressure and Manual Shut Down Options) SELECTION, APPLICATION AND MAINTENANCE Valve Numbers D92-AP
More informationSF15K SF05KSS, SF10KSS
Product Instruction Manual Speedflow SF05K, SF10K & SF15K SF05KSS, SF10KSS & SF15KSS Undersink unvented water heater V15.6/6 Version 3.2 Jan 2015 Thank you for purchasing a Hyco Speedflow unvented water
More informationSpecifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.
Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical
More informationThermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) Description RAVV can be combined with 2-way valves RAV- /8, VMT-/8 or VMA 15. Controller closes on rising temperature. There is a special
More informationOwner s Manual. & Installation guide. Installation Details Owner s Information Warranty. 4 Star Gas Hot Water Heater
Owner s Manual & Installation guide Models 135THM4N 135THM4P 170THM4N 170THM4P Installation Details Owner s Information Warranty For advice, repairs and service, call: 1800 080 055 Carefully remove all
More informationAutomatic Control Valves WATTS EU 100 Series
utomatic ontrol Valves WTTS U Series The Watts Industries range of automatic control valves consist of a hydraulically operated valve, which is controlled by a pilot circuit. The main valve (U ) is the
More informationMustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE
More informationItho Products for Hot and Boiling water. product-
Itho Products for Hot and Boiling water product- 2 This booklet provides additional information on the range of hot and boiling water appliances by Itho. The data will allow you to determine which product
More informationPRESSURE REDUCING CONTROL VALVE
Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line
More informationThermostatic Valve Replacement Cartridge and Rebuild Kit
Thermostatic Valve Replacement Cartridge and Rebuild Kit Installation Instructions Rebuild kit for Ondine Thermostatic Mixing Valves including Models 25071 (1/2-inch) and 25072 (3/4-inch). Also fits models
More informationRADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS
RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS MANIFOLD ASSEMBLIES ONE-PIPE Compatible with most radiators on the market, this pre-assembled manifold for one-pipe radiator systems delivers balancing
More informationSHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced
More informationArtisan Thermostatic Bath Shower Mixer
Artisan Thermostatic Bath Shower Mixer Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts General Information Thank you for choosing
More informationTroubleshoot resources for homeowner http://waterheatertimer.org/troubleshoot-bosch-tankless-water-heater.html
Troubleshoot resources for homeowner http://waterheatertimer.org/troubleshoot-bosch-tankless-water-heater.html Installation / Operating Instructions GOOD.BEETER>BOSCH Water Wizard 600 Continuous Flow Gas
More informationMax primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
More informationBACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: 3402270 & 3402275 OPERATING & MAINTENANCE INSTRUCTIONS GC04/12
BACKPACK SPRAYERS MODEL NOS: KSP16 & KSP20 Part Nos: 3402270 & 3402275 OPERATING & MAINTENANCE INSTRUCTIONS GC04/12 INTRODUCTION Thank you for purchasing this CLARKE Sprayer, designed for use only with
More informationDesign Utility Lever Thermostatic Bath Shower Mixer
Design Utility Lever Thermostatic Bath Shower Mixer Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts General Information Thank
More informationArtisan Thermostatic basin mixer. Fitting Instructions & Contents List
Artisan Thermostatic basin mixer Fitting Instructions & Contents List Please keep these instructions for future reference and request of replacement parts 1. Introduction Thank you for choosing Bristan,
More information3/2- and 2/2-way cartridge valve type BVE
3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type
More informationProducts no longer available
Technical ata sheet R6..R haracterize control valves, 2-way, with flange PN 6 for open an close col an warm water systems for moulating control on the water sie of air-hanling an heating systems air bubble-tight
More informationITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.
ITE Indirect calorifier ITE - 400/500/600/750/1000 0310 117 Installation, User and Service Manual Innovation has a name. Read this manual carefully Warning Read this manual carefully before starting the
More informationCombi 24 HE. User s Guide and Important Warranty Information
User s Guide and Important Warranty Information Combi 4 HE Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Baxi Heating UK Ltd 0 Contents
More informationProduct Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description
Product Manual CVS Type 67AFR Filter Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS Type 67AFR
More informationHow To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationPOWER PULSE VALVES remote pilot threaded or Quick Mount connection 3/4 to 1 1/2
POWR PULS VLVS pilot threaded or Quick Mount 3/4 to 1 1/2 N 2/2 Series 353 TURS The piston cartridge pulse valves are especially designed for dust collector service applications, combining high flow, long
More information820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.
SIT Group 820 NOVA mv MULTIFUNCTIONAL CONTROL FOR GAS THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE PIN 3AP700/2 SINGLE-KNOB MULTIFUNCTIONAL
More informationOwner s Manual. Installation Details Owner s Information. 80L to 400L Electric Storage Water Heaters
Models: RIN80E24 RIN80E36 RIN125E24 RIN125E36 RIN160E24 RIN160E36 RIN250E36 RIN315E36 RIN400E36 Installation Details Owner s Information For advice, repairs and service, call: 1300 555 545 Carefully remove
More informationCALEFFI. SATK wall-mounted Heat Interface Unit - HIU Instantaneous domestic hot water production. SATK20 - SATK30 series 01209/13 GB
SATK wall-mounted Heat Interface Unit - HIU Instantaneous domestic hot water production SATK20 - SATK30 series ACCREDITED CALEFFI 01209/13 GB ISO 9001 FM 21654 ISO 9001 No. 0003 The latest generation heat
More informationShower Handbook (Also covers 650 chrome variant)
Shower Handbook (Also covers 650 chrome variant) IMPORTANT: Please retain this booklet for future reference CONTENTS Page How to use your shower 2 How your shower works 3 What to do if things go wrong
More informationModulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, 1060. Instruction No.
Instruction No. AERCO INTERNATIONAL, Inc., Northvale, New Jersey, 07647 USA PIPING GUIDE GF-115-P Modulex Gas Fired Boiler Systems Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909,
More informationValve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More informationSelf-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23
Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23 Application Pressure regulators for set points from 5 mbar to 28 bar Valves in nominal sizes DN 15 to 100 Nominal pressures
More informationSafe Touch TMV3 Thermostatic Shower ST10010CP
Safe Touch TMV3 Thermostatic Shower ST10010CP Installation and Maintenance Instructions 38 In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept
More informationHEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
More informationVersion: 1.0 TWO HANDLES INWALL WATERFALL FAUCET INSTALL GUIDE
MODEL: S1248CW Version: 1.0 TWO HANDLES INWALL WATERFALL FAUCET INSTALL GUIDE Dear Valued Customer, SUMERAIN would like to take this opportunity to thank you for purchasing SUMERAIN products. It is our
More informationMAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure
MAKING MODERN LIVING POSSIBLE Thermostatic valve AVTA Technical brochure 2 IC.PD.500.A3.02-520B3728 Danfoss A/S 07-2009/ RA-MC/mr Contents Page Features............................................................................................4
More informationIsotemp Basic, Slim/B & Slim Square
Isotemp Basic, Slim/B & Slim Square Water heater Installation and operating instructions Indel Marine S.r.l. Zona Artigianale sn IT-61019 S. Agata Feltria (PU) Italy Tel. 39 0541 848 030 Fax 39 0541 848
More informationMikrotherm. Manual radiator valves. To be precise.
Manual radiator valves To be precise. Description HEIMEIER Mikrotherm manual radiator valves made of corrosion-resistant gunmetal, with white plastic hand wheel cap, tight-packed with protection film.
More informationTECHNICAL INSTRUCTIONS REPAIR KITS Hydroguard Series 420 Thermostatic Valve All Models (1 9)
Form TI420-KIT A Watts Industries Co. TECHNICAL INSTRUCTIONS REPAIR KITS Hydroguard Series 420 Thermostatic Valve All Models (1 9) DESCRIPTION Thank you for purchasing a Powers kit. The Powers kit you
More informationCERT. TO ASSE STD 1016 AND 1017 1016 AND 1017 1016 AND 1017 WT. LBS.
SUBMITTAL DATA/INSTRUCTION SHEET SD/IS 150 EFFECTIVE September 004 Supercedes March 3, 004 AM-1 SERIES TM ANTI-SCALD PROPORTIONAL THERMOSTATIC MIXING DIVERTING VALVE PATENTED, WITH DUAL ASSE 10 CERTIFICATION,
More informationStainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
More informationTHESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER
BTH & THERMOSTTIC SHOWER CONTROL Installation Operation &B Maintenance Guide THESE INSTRUCTIONS RE TO BE LEFT WITH THE USER 1 Contents 1... Important Safety Information... 3 2... Introduction...4 3...
More information*h5h/7h$ù,5,7ø75(ùø0/(59(68.$d$./$5, <$1/,ù0217$-'$1.$<1$./$1$%ø/ø5 &ø+$=,$6/$d$/,ù0$67$1',h=(5ø1'( 7$ù,0$<,1,=
10600834.fm Page 1 Thursday, January 11, 2007 6:07 PM TR 0217$-.,/$98=8 *h5h/7h$ù,5,7ø75(ùø0/(59(68.$d$./$5,
More informationThermostatic valve Type AVTA
MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The
More informationUnvented water heater
Unvented water heater Description of water heater 1)Hot water outlet 2)Temperature and pressure relief valve (30 litre only) 3)Cold water inlet 4)Control cover 5)Regulation knob 6)Heating neon 1 4 5 6
More informationMira Extra Bath and Thermostatic Shower Control
Mira Extra Bath and Thermostatic Shower Control For SPRES, DVICE or REPIRS Please call us on 0844 571 5000 (UK Only) These instructions must be left with the user Installation & User Guide 1 SFETY : WRNINGS
More informationNAVIEN AMERICA INC. 17855 FITCH AVENUE
Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:
More informationErgo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
More informationDirect Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40
Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane
More informationModel 2128 AIR COMPRESSOR PUMP Operating Instructions
Model 8 AIR COMPRESSOR PUMP Operating Instructions Assembly of pump Connection to cylinder and charging ) Connect the air hose to the air cylinder and tighten with spanner. Do not over tighten. Note; the
More informationColonial Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts
Colonial Tap Range Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the UK s leading
More informationInstallation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25
PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions Domestic hot water modules:
More informationDARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES
SECTION 15062 STEAM AND CONDENSATE PIPING PART 1 DESIGN DIRECTIVES 1.1 QUALITY ASSURANCE A. Comply with the provisions of the following: 1.2 DESIGN CRITERIA 1. ASME B 31.9 Building Services Piping : for
More informationSTC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting
STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting Female NPT Thread 3/8 OD Tube 3/8 Push-In Fitting 2P050 Series Solenoid Valve Specifications Valve Model 2P050-1/4 2P050-3/8
More informationBoiler & Pressure Vessel Inspection discrepancies and failures
Boiler & Pressure Vessel Inspection discrepancies and failures Water Heaters / Pressure Vessels Pressure Vessels are inspected once every three years. This requires a test of A: safety relief devices B:
More informationTA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.
TA-FUS1ON Fully adjustable Kvs control and balancing valves. That s just two good. Supported by the Reece hvac-r network. Through our 36 stores around Australia, Reece hvac-r is committed to supporting
More informationArtisan Thermostatic bath shower mixer. Fitting Instructions & Contents List
Artisan Thermostatic bath shower mixer Fitting Instructions & Contents List Please keep these instructions for future reference and request of replacement parts Contents Page 1. Introduction 03 2. Specification
More informationINSTALLATION INSTRUCTIONS BL-8704
INSTALLATION INSTRUCTIONS BL-8704 EXPOSED BLACK LEVER THERMOSTATIC MIXING VALVE WITH RISER KIT, HANDSET, LEVER DIVERTER, 8 ROSE AND ADJUSTABLE RISER PIPE BRACKET. Dimensions in Inches (& Millimetres) 1
More informationAUTOMATIC AIR VENT VALVES MANUAL VALVES FOR DISCHARGING AIR FROM RADIATORS
01B101-GB AUTOMATIC AIR VENT VALVES MANUAL VALVES FOR DISCHARGING AIR FROM RADIATORS MAIN FEATURES ADVANTAGE OF BUILT-IN MANUAL DISCHARGE - Provision for controlling operation of the automatic discharge
More informationInstallation and Operating Instructions Installation Instructions for SS EPE-316L Series
INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This
More informationAMX300 DirectConnect Mixing Valve Kits
AMX300 DirectConnect Mixing Valve Kits INSTALLATION INSTRUCTIONS Tools needed (not supplied) 1. Wrench 2. Pliers Safety Definitions These safety terms identify information you must read. CAUTION Indicates
More informationThis section gives you some helpful information and tips on running your home and the equipment in it.
67 This section gives you some helpful information and tips on running your home and the equipment in it. Electricity Fuse board (electrical consumer unit) Make sure you know where your fuse board is and
More informationINSTALLATION INSTRUCTIONS MK-8704
INSTALLATION INSTRUCTIONS MK-8704 EXPOSED MACKINTOSH THERMOSTATIC MIXING VALVE WITH RISER KIT, HANDSET, LEVER DIVERTER, 8 ROSE AND ADJUSTABLE RISER PIPE BRACKET. Dimensions in Inches (& Millimetres) 1
More informationINSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)
CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage
More informationELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
More informationBERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features
Pressure Reducing Valve Flow and leakage reduction Cavitation damage protection Throttling noise reduction Burst protection System maintenance savings The Pressure Reducing Valve is a hydraulically operated,
More information- Do not immerse cords, pump or any electrical wire or device in water or other liquid.
TRANSFER PUMP INSTRUCTIONS FOR THE SUPER TRANSFER PUMP 1. Pump (water may be present in the pump and lines due to testing at factory) 2. Instructions. 3. Inlet thicker wall hose (1), outlet hose (1) 4.
More informationThermostatic element RAVV for 2-way valves
Description / Application RAVV is a self-acting thermostatic element which can be combined with 2-way valve bodies RAV-/8, VMT-/8 or VMA 15. RAVV is used to control temperatures in small hot water cylinders
More informationVAD Variable Area Desuperheaters
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationInstallation and Servicing Instructions. Alpha 240/280. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers
Installation and Servicing Instructions Alpha 240/280 Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers For Technical help or for Service call... ALPHA HELPLINE Tel: 0870
More informationSTAINLESS STEEL TANK TABLE OF CONTENTS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 TANK & JACKET ASSEMBLY... 4.
TABLE OF CONTENTS STAINLESS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 & JACKET ASSEMBLY... 4 SST Section 052506 1 Troubleshooting performed by untrained personnel could result in electrical
More informationFig B36 Stainless Steel 'T' Type or Basket Type Strainers
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationSafety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage
Safety for Hydraulics Leak free check valve, pilot operated, series Cartridge type, two stage prevents a load from falling if a burst occurs in feed pipe hardened seat and poppet prevents creep of hydraulically
More informationGuidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters
Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters When water is heated, it naturally expands and allowance has to be made for this. Vented water heaters usually
More informationWatts Pure Water Systems
Watts Pure Water Systems WM-120-PT Installation and Operation Manual Premier Water Systems Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before
More information