ASCO 920 Product Specifications

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "ASCO 920 Product Specifications"

Transcription

1 ASCO is the global leader in power switching and controls ASCO 90 Product Specifications Only (Panelboard Mounting),,. Suitable insulation must be behind switch unit.. Suitable for bus bar mounting. Lugs not supplied.. Dimensional data is approximate and subject to change. -/ (0) 8-/ () -/ (89) 0-00 (.) -/ (0) 9-/ () -/ (89) 0- (.) With Sub-Panel (Panelboard Mounting) NEMA Type Enclosure -/ (0) -/(98) -/8 (98) (0) 8-/() -/ () 8(.) -/ (0) -/(8) -/(00) (0) -/ () (.0) (0) (0.) (.0). Enclosure gutter spaces are based on non-looping of cables within the enclosure. Where cables must be looped within the enclosure, oversize cabinets are available at extra cost. Contact ASCO for complete information. Maximum Voltage s at Rated, Open or Enclosed When Connected Pole to Load VAC 0 VAC VAC When Connected Poles to Load on and Poles to Load on 80 VAC 0 VAC 00 VAC A SCO Power Te chnologies 0 Hanover Road F l o r ham Park, NJ 09 USA A SCO w w w. em er so n n et workpower.com / A SCO w w w. ascoapu.co m. For DC service, maximum current rating is amps or switch rating, whichever is less, with maximum voltage rating of volts when connected pole to load and 0 volts when connected poles to load. Current Values and Recommended Control Circuit Size,, Volts, 0 Hz 0 0 Volts, 0 Hz 8 0 Volts, 0 Hz 80 Volts, 0 Hz. Overcurrent protective device ratings for control circuits should be selected and installed in accordance with the NEC.. This table shows the minimum permissible control circuit fuse size, based on the operating coil s momentary inrush current. 8. ASCO furnished control fuses are rated at. Wire Size for Service and Control Connections 9, AL or CU Terminal Lug Wire Range AWG-MCM / Maximum Distance Between Control Station and One ASCO 90 RC with Source Line Voltage at 90% of Normal of Cable per Terminal Lug Connector Control circuit connections are supplied with terminals accommodate a copper wire range of # AWG to #0 AWG. 0. Service connection for switches on sub-panels are furnished with solderless lugs to accommodate copper or aluminum wire, except on 0 Amp size which is provided with / studs. 0- AWG 0 0 Distance in Feet, 0 Volts, 0 Volts, Volts, If the control device does not have adequate current-carrying capacity to control the switch directly, or the control station is to be located a greater distance from the switch than is allowed in the above table, auxiliary control relays for -wire, or -wire control are available. See optional accessories on inside tab.. For 08 volt system, reduce 0 volt values by %.. For volt system, reduce volt values by %. Emerson Network Power. The global leader in enabling Business-Critical ContinuityTM. AC Power Connectivity Embedded Computing Embedded Power Infrastructure Management & Monitoring Outside Plant DC Power Industrial Power Power ing & Controls EmersonNetworkPower.com Precision Cooling Racks & Integrated Cabinets Services Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. 0 Emerson Electric Co. Publication 0 R September, 0 Printed in the U.S.A.

2 Maximum reliability and excellent value ASCO 90 Remote Control (RC) es ASCO 90 Remote Control in Type Enclosure The ASCO 90 is designed as a feeder disconnect switch for load capacities beyond the ASCO 9. ASCO 90 RC switches are available for separate mounting in NEMA type enclosures or direct mounting within lighting panelboards for total or splitbus applications. It is available from 0 through Amperes per pole with or poles and service voltages through 00 volts AC. The ASCO 90 is listed under UL 08 for ballast lighting, tungsten, general use and resistive loads. It also ASCO 90 Ordering Information meets the withstand current requirements of UL for panelboard applications. The ASCO 90 is easy to install and features all position mounting, no derating for high inrush loads and a reliable single-solenoid operator. ASCO 90 RC switches can be used with energy management systems which automatically control lighting and power circuits through control devices such as photoelectric cells, microprocessors, timers and occupancy sensors. Product Code of Poles 90 Continuous Ampere UL listed. CSA Approved Meets UL requirements with short-circuit rating (Withstand Current ) of,000 rms symmetrical at 80 volts for use with molded case circuit breakers; 00,000 rms symmetrical at 00 volts for use with currentlimiting fuses. Interrupts 00% of rated current at 80 volts, 0. to 0. power factor ASCO 90 Optional Auxiliary Control Relays Features Voltage Code AC/DC AC Voltage to 0V 08 to 0V to V 0 to 80V 9 Other Voltages Up to 80 X Sub-Panel Code 0 = No Sub Panel = Sub-Panel Enclosures Options Leave Blank for No Options. X Indicates Options. List Separately. See Below. Leave Blank for Open - Type. C Indicates NEMA Type, or Specify Other Type Required.. For DC service, maximum current rating is or switch rating, whichever is less, with maximum voltage rating of volts when connected pole to load and 0 volts when connected poles to the load.. All at 0 or 0 Hz. For voltages other than those listed, and for DC applications, contact your nearest ASCO source.. Specified only when ASCO 90 is to be mounted within a panelboard. A sub-panel is required when mounting in NEMA type enclosures Example: The catalog number for an ASCO 90, -pole, -amp switch with a control coil voltage of volts, 0 Hz, with an Optional Accessory 8 and a sub-panel, in a NEMA Type enclosure is: 90XC with option 8A(0V) Allows control of RC switches directly from energy management systems. UL recognized for use with ASCO RC switches. Permits low voltage AC or DC normal. Polycarbonate dust cover for protection against industrial environment. Barrier screw type terminals with approved means for solderless connection of conductors. Low VA burden. Auxiliary Control Relays to Operate RC es are useful when: When the controlling device does not have adequate current-carrying capacity to directly control the RC switch. When the control station is to be located at a distance greater than the allowable RC switch line run. When the controlling device is only available as a single pole, single throw contact, necessitating a two-wire control line. Narrow width design. Incorporates ASCO relays. When Form (start-stop) control for an RC switch is required. Two-Wire Control Accessory Catalog A0 Two-wire ASCO relay for two-wire control. ASCO 90 Features Electrical Features The largest service organization of its kind Creative, responsive, customer - focused and competitive. Optional Accessories Can be used with metal halide, mercury vapor, quartz halogen, tungsten and fluorescent lighting. No derating when used on high inrush loads such as cold tungsten lamps. Wide arc gaps and arc splitters to quickly extinguish arcs. Isolated arcing chambers are widely spaced and symmetrically located. Construction Features Long life. Designed for more demanding lighting contactor use. Provides extended life and quieter operation. Suitable for use with energy management systems. Rugged molded base and cover with superior electrical insulation. Control line terminal clamps simplify installation: Insert wire and tighten. Wire range # AWG to #0 AWG. Option Description Auxiliary contacts, one normally open and one normally closed. Supplied as a pair. Rated 0 amps at 80 VAC. Fully-rated neutral plate Auxiliary control relay for -wire control Auxiliary control relay for -wire control Auxiliary control relay for Form control Control line fuse: For grounded control voltage (to 00V) For ungrounded control voltage (to 00V) For ungrounded control voltage (0-00V) Contacts are power-driven in both directions for complete dependability. No extra wires or contacts needed to install signal lamps at control stations. Can be mounted in any Provisions for manual position. operation during inspection and maintenance. Available from stock from 0-. Lightweight for easy installation. Plug-in auxiliary control relays available. ASCO 90 Remote Control with sub-panel See Notes Specify Option A and B,,,,,, 8 9, A B C. A maximum of one pair of optional A and B contacts can be supplied on the above indicated remote es.. The Amperage of the neutral plate will be equal to the Amperage of the specified remote. Lugs capable of accommodating the same cables as a single main pole are provided.. When ordering specify desired control voltage. See next page for control voltages.. Control line fuses can be used to supply power from the remote enclosures to external control stations. Any incoming service or control power should have appropriate overcurrent protection at their source as required by application codes. For a grounded control voltage, one fuse should be ordered; for an ungrounded control voltage, two fuses should be ordered.. Shipped loose for open types. Installed for enclosed types.. U.L. recognized.,0, 08, 0, VAC, 0 or, or 0VDC Accessory Three-Wire Control Accessory 8 Catalog A Three-wire ASCO relay for three-wire control.,0, 08, 0, VAC, 0 or,,,, 8 or 0VDC Accessory 8 Dimensions inches (mm) for ASCO two-wire and three-wire Control Relays -/ (mm) (mm) -/8 8 (mm). Dimensional data is approximate and subject to change. Operating Coil Characteristics Accessory Accessory 8 Nominal AC Pickup Voltage AC Nominal DC Pickup Voltage DC Maximum Voltage.0 VA. Watts 80% of Nominal 0% of Nominal.0 VA. Watts % of Nominal 0% of Nominal

3 ASCO is the global leader in power switching and controls ASCO 90 Product Specifications Only (Panelboard Mounting),,. Suitable insulation must be behind switch unit.. Suitable for bus bar mounting. Lugs not supplied.. Dimensional data is approximate and subject to change. -/ (0) 8-/ () -/ (89) 0-00 (.) -/ (0) 9-/ () -/ (89) 0- (.) With Sub-Panel (Panelboard Mounting) NEMA Type Enclosure -/ (0) -/(98) -/8 (98) (0) 8-/() -/ () 8(.) -/ (0) -/(8) -/(00) (0) -/ () (.0) (0) (0.) (.0). Enclosure gutter spaces are based on non-looping of cables within the enclosure. Where cables must be looped within the enclosure, oversize cabinets are available at extra cost. Contact ASCO for complete information. Maximum Voltage s at Rated, Open or Enclosed When Connected Pole to Load VAC 0 VAC VAC When Connected Poles to Load on and Poles to Load on 80 VAC 0 VAC 00 VAC A SCO Power Te chnologies 0 Hanover Road F l o r ham Park, NJ 09 USA A SCO w w w. em er so n n et workpower.com / A SCO w w w. ascoapu.co m. For DC service, maximum current rating is amps or switch rating, whichever is less, with maximum voltage rating of volts when connected pole to load and 0 volts when connected poles to load. Current Values and Recommended Control Circuit Size,, Volts, 0 Hz 0 0 Volts, 0 Hz 8 0 Volts, 0 Hz 80 Volts, 0 Hz. Overcurrent protective device ratings for control circuits should be selected and installed in accordance with the NEC.. This table shows the minimum permissible control circuit fuse size, based on the operating coil s momentary inrush current. 8. ASCO furnished control fuses are rated at. Wire Size for Service and Control Connections 9, AL or CU Terminal Lug Wire Range AWG-MCM / Maximum Distance Between Control Station and One ASCO 90 RC with Source Line Voltage at 90% of Normal of Cable per Terminal Lug Connector Control circuit connections are supplied with terminals accommodate a copper wire range of # AWG to #0 AWG. 0. Service connection for switches on sub-panels are furnished with solderless lugs to accommodate copper or aluminum wire, except on 0 Amp size which is provided with / studs. 0- AWG 0 0 Distance in Feet, 0 Volts, 0 Volts, Volts, If the control device does not have adequate current-carrying capacity to control the switch directly, or the control station is to be located a greater distance from the switch than is allowed in the above table, auxiliary control relays for -wire, or -wire control are available. See optional accessories on inside tab.. For 08 volt system, reduce 0 volt values by %.. For volt system, reduce volt values by %. Emerson Network Power. The global leader in enabling Business-Critical ContinuityTM. AC Power Connectivity Embedded Computing Embedded Power Infrastructure Management & Monitoring Outside Plant DC Power Industrial Power Power ing & Controls EmersonNetworkPower.com Precision Cooling Racks & Integrated Cabinets Services Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. 0 Emerson Electric Co. Publication 0 R September, 0 Printed in the U.S.A.

4 Maximum reliability and excellent value ASCO 90 Remote Control (RC) es ASCO 90 Remote Control in Type Enclosure The ASCO 90 is designed as a feeder disconnect switch for load capacities beyond the ASCO 9. ASCO 90 RC switches are available for separate mounting in NEMA type enclosures or direct mounting within lighting panelboards for total or splitbus applications. It is available from 0 through Amperes per pole with or poles and service voltages through 00 volts AC. The ASCO 90 is listed under UL 08 for ballast lighting, tungsten, general use and resistive loads. It also ASCO 90 Ordering Information meets the withstand current requirements of UL for panelboard applications. The ASCO 90 is easy to install and features all position mounting, no derating for high inrush loads and a reliable single-solenoid operator. ASCO 90 RC switches can be used with energy management systems which automatically control lighting and power circuits through control devices such as photoelectric cells, microprocessors, timers and occupancy sensors. Product Code of Poles 90 Continuous Ampere UL listed. CSA Approved Meets UL requirements with short-circuit rating (Withstand Current ) of,000 rms symmetrical at 80 volts for use with molded case circuit breakers; 00,000 rms symmetrical at 00 volts for use with currentlimiting fuses. Interrupts 00% of rated current at 80 volts, 0. to 0. power factor ASCO 90 Optional Auxiliary Control Relays Features Voltage Code AC/DC AC Voltage to 0V 08 to 0V to V 0 to 80V 9 Other Voltages Up to 80 X Sub-Panel Code 0 = No Sub Panel = Sub-Panel Enclosures Options Leave Blank for No Options. X Indicates Options. List Separately. See Below. Leave Blank for Open - Type. C Indicates NEMA Type, or Specify Other Type Required.. For DC service, maximum current rating is or switch rating, whichever is less, with maximum voltage rating of volts when connected pole to load and 0 volts when connected poles to the load.. All at 0 or 0 Hz. For voltages other than those listed, and for DC applications, contact your nearest ASCO source.. Specified only when ASCO 90 is to be mounted within a panelboard. A sub-panel is required when mounting in NEMA type enclosures Example: The catalog number for an ASCO 90, -pole, -amp switch with a control coil voltage of volts, 0 Hz, with an Optional Accessory 8 and a sub-panel, in a NEMA Type enclosure is: 90XC with option 8A(0V) Allows control of RC switches directly from energy management systems. UL recognized for use with ASCO RC switches. Permits low voltage AC or DC normal. Polycarbonate dust cover for protection against industrial environment. Barrier screw type terminals with approved means for solderless connection of conductors. Low VA burden. Auxiliary Control Relays to Operate RC es are useful when: When the controlling device does not have adequate current-carrying capacity to directly control the RC switch. When the control station is to be located at a distance greater than the allowable RC switch line run. When the controlling device is only available as a single pole, single throw contact, necessitating a two-wire control line. Narrow width design. Incorporates ASCO relays. When Form (start-stop) control for an RC switch is required. Two-Wire Control Accessory Catalog A0 Two-wire ASCO relay for two-wire control. ASCO 90 Features Electrical Features The largest service organization of its kind Creative, responsive, customer - focused and competitive. Optional Accessories Can be used with metal halide, mercury vapor, quartz halogen, tungsten and fluorescent lighting. No derating when used on high inrush loads such as cold tungsten lamps. Wide arc gaps and arc splitters to quickly extinguish arcs. Isolated arcing chambers are widely spaced and symmetrically located. Construction Features Long life. Designed for more demanding lighting contactor use. Provides extended life and quieter operation. Suitable for use with energy management systems. Rugged molded base and cover with superior electrical insulation. Control line terminal clamps simplify installation: Insert wire and tighten. Wire range # AWG to #0 AWG. Option Description Auxiliary contacts, one normally open and one normally closed. Supplied as a pair. Rated 0 amps at 80 VAC. Fully-rated neutral plate Auxiliary control relay for -wire control Auxiliary control relay for -wire control Auxiliary control relay for Form control Control line fuse: For grounded control voltage (to 00V) For ungrounded control voltage (to 00V) For ungrounded control voltage (0-00V) Contacts are power-driven in both directions for complete dependability. No extra wires or contacts needed to install signal lamps at control stations. Can be mounted in any Provisions for manual position. operation during inspection and maintenance. Available from stock from 0-. Lightweight for easy installation. Plug-in auxiliary control relays available. ASCO 90 Remote Control with sub-panel See Notes Specify Option A and B,,,,,, 8 9, A B C. A maximum of one pair of optional A and B contacts can be supplied on the above indicated remote es.. The Amperage of the neutral plate will be equal to the Amperage of the specified remote. Lugs capable of accommodating the same cables as a single main pole are provided.. When ordering specify desired control voltage. See next page for control voltages.. Control line fuses can be used to supply power from the remote enclosures to external control stations. Any incoming service or control power should have appropriate overcurrent protection at their source as required by application codes. For a grounded control voltage, one fuse should be ordered; for an ungrounded control voltage, two fuses should be ordered.. Shipped loose for open types. Installed for enclosed types.. U.L. recognized.,0, 08, 0, VAC, 0 or, or 0VDC Accessory Three-Wire Control Accessory 8 Catalog A Three-wire ASCO relay for three-wire control.,0, 08, 0, VAC, 0 or,,,, 8 or 0VDC Accessory 8 Dimensions inches (mm) for ASCO two-wire and three-wire Control Relays -/ (mm) (mm) -/8 8 (mm). Dimensional data is approximate and subject to change. Operating Coil Characteristics Accessory Accessory 8 Nominal AC Pickup Voltage AC Nominal DC Pickup Voltage DC Maximum Voltage.0 VA. Watts 80% of Nominal 0% of Nominal.0 VA. Watts % of Nominal 0% of Nominal

5 Maximum reliability and excellent value ASCO 90 Remote Control (RC) es ASCO 90 Remote Control in Type Enclosure The ASCO 90 is designed as a feeder disconnect switch for load capacities beyond the ASCO 9. ASCO 90 RC switches are available for separate mounting in NEMA type enclosures or direct mounting within lighting panelboards for total or splitbus applications. It is available from 0 through Amperes per pole with or poles and service voltages through 00 volts AC. The ASCO 90 is listed under UL 08 for ballast lighting, tungsten, general use and resistive loads. It also ASCO 90 Ordering Information meets the withstand current requirements of UL for panelboard applications. The ASCO 90 is easy to install and features all position mounting, no derating for high inrush loads and a reliable single-solenoid operator. ASCO 90 RC switches can be used with energy management systems which automatically control lighting and power circuits through control devices such as photoelectric cells, microprocessors, timers and occupancy sensors. Product Code of Poles 90 Continuous Ampere UL listed. CSA Approved Meets UL requirements with short-circuit rating (Withstand Current ) of,000 rms symmetrical at 80 volts for use with molded case circuit breakers; 00,000 rms symmetrical at 00 volts for use with currentlimiting fuses. Interrupts 00% of rated current at 80 volts, 0. to 0. power factor ASCO 90 Optional Auxiliary Control Relays Features Voltage Code AC/DC AC Voltage to 0V 08 to 0V to V 0 to 80V 9 Other Voltages Up to 80 X Sub-Panel Code 0 = No Sub Panel = Sub-Panel Enclosures Options Leave Blank for No Options. X Indicates Options. List Separately. See Below. Leave Blank for Open - Type. C Indicates NEMA Type, or Specify Other Type Required.. For DC service, maximum current rating is or switch rating, whichever is less, with maximum voltage rating of volts when connected pole to load and 0 volts when connected poles to the load.. All at 0 or 0 Hz. For voltages other than those listed, and for DC applications, contact your nearest ASCO source.. Specified only when ASCO 90 is to be mounted within a panelboard. A sub-panel is required when mounting in NEMA type enclosures Example: The catalog number for an ASCO 90, -pole, -amp switch with a control coil voltage of volts, 0 Hz, with an Optional Accessory 8 and a sub-panel, in a NEMA Type enclosure is: 90XC with option 8A(0V) Allows control of RC switches directly from energy management systems. UL recognized for use with ASCO RC switches. Permits low voltage AC or DC normal. Polycarbonate dust cover for protection against industrial environment. Barrier screw type terminals with approved means for solderless connection of conductors. Low VA burden. Auxiliary Control Relays to Operate RC es are useful when: When the controlling device does not have adequate current-carrying capacity to directly control the RC switch. When the control station is to be located at a distance greater than the allowable RC switch line run. When the controlling device is only available as a single pole, single throw contact, necessitating a two-wire control line. Narrow width design. Incorporates ASCO relays. When Form (start-stop) control for an RC switch is required. Two-Wire Control Accessory Catalog A0 Two-wire ASCO relay for two-wire control. ASCO 90 Features Electrical Features The largest service organization of its kind Creative, responsive, customer - focused and competitive. Optional Accessories Can be used with metal halide, mercury vapor, quartz halogen, tungsten and fluorescent lighting. No derating when used on high inrush loads such as cold tungsten lamps. Wide arc gaps and arc splitters to quickly extinguish arcs. Isolated arcing chambers are widely spaced and symmetrically located. Construction Features Long life. Designed for more demanding lighting contactor use. Provides extended life and quieter operation. Suitable for use with energy management systems. Rugged molded base and cover with superior electrical insulation. Control line terminal clamps simplify installation: Insert wire and tighten. Wire range # AWG to #0 AWG. Option Description Auxiliary contacts, one normally open and one normally closed. Supplied as a pair. Rated 0 amps at 80 VAC. Fully-rated neutral plate Auxiliary control relay for -wire control Auxiliary control relay for -wire control Auxiliary control relay for Form control Control line fuse: For grounded control voltage (to 00V) For ungrounded control voltage (to 00V) For ungrounded control voltage (0-00V) Contacts are power-driven in both directions for complete dependability. No extra wires or contacts needed to install signal lamps at control stations. Can be mounted in any Provisions for manual position. operation during inspection and maintenance. Available from stock from 0-. Lightweight for easy installation. Plug-in auxiliary control relays available. ASCO 90 Remote Control with sub-panel See Notes Specify Option A and B,,,,,, 8 9, A B C. A maximum of one pair of optional A and B contacts can be supplied on the above indicated remote es.. The Amperage of the neutral plate will be equal to the Amperage of the specified remote. Lugs capable of accommodating the same cables as a single main pole are provided.. When ordering specify desired control voltage. See next page for control voltages.. Control line fuses can be used to supply power from the remote enclosures to external control stations. Any incoming service or control power should have appropriate overcurrent protection at their source as required by application codes. For a grounded control voltage, one fuse should be ordered; for an ungrounded control voltage, two fuses should be ordered.. Shipped loose for open types. Installed for enclosed types.. U.L. recognized.,0, 08, 0, VAC, 0 or, or 0VDC Accessory Three-Wire Control Accessory 8 Catalog A Three-wire ASCO relay for three-wire control.,0, 08, 0, VAC, 0 or,,,, 8 or 0VDC Accessory 8 Dimensions inches (mm) for ASCO two-wire and three-wire Control Relays -/ (mm) (mm) -/8 8 (mm). Dimensional data is approximate and subject to change. Operating Coil Characteristics Accessory Accessory 8 Nominal AC Pickup Voltage AC Nominal DC Pickup Voltage DC Maximum Voltage.0 VA. Watts 80% of Nominal 0% of Nominal.0 VA. Watts % of Nominal 0% of Nominal

6 ASCO is the global leader in power switching and controls ASCO 90 Product Specifications Only (Panelboard Mounting),,. Suitable insulation must be behind switch unit.. Suitable for bus bar mounting. Lugs not supplied.. Dimensional data is approximate and subject to change. -/ (0) 8-/ () -/ (89) 0-00 (.) -/ (0) 9-/ () -/ (89) 0- (.) With Sub-Panel (Panelboard Mounting) NEMA Type Enclosure -/ (0) -/(98) -/8 (98) (0) 8-/() -/ () 8(.) -/ (0) -/(8) -/(00) (0) -/ () (.0) (0) (0.) (.0). Enclosure gutter spaces are based on non-looping of cables within the enclosure. Where cables must be looped within the enclosure, oversize cabinets are available at extra cost. Contact ASCO for complete information. Maximum Voltage s at Rated, Open or Enclosed When Connected Pole to Load VAC 0 VAC VAC When Connected Poles to Load on and Poles to Load on 80 VAC 0 VAC 00 VAC A SCO Power Te chnologies 0 Hanover Road F l o r ham Park, NJ 09 USA A SCO w w w. em er so n n et workpower.com / A SCO w w w. ascoapu.co m. For DC service, maximum current rating is amps or switch rating, whichever is less, with maximum voltage rating of volts when connected pole to load and 0 volts when connected poles to load. Current Values and Recommended Control Circuit Size,, Volts, 0 Hz 0 0 Volts, 0 Hz 8 0 Volts, 0 Hz 80 Volts, 0 Hz. Overcurrent protective device ratings for control circuits should be selected and installed in accordance with the NEC.. This table shows the minimum permissible control circuit fuse size, based on the operating coil s momentary inrush current. 8. ASCO furnished control fuses are rated at. Wire Size for Service and Control Connections 9, AL or CU Terminal Lug Wire Range AWG-MCM / Maximum Distance Between Control Station and One ASCO 90 RC with Source Line Voltage at 90% of Normal of Cable per Terminal Lug Connector Control circuit connections are supplied with terminals accommodate a copper wire range of # AWG to #0 AWG. 0. Service connection for switches on sub-panels are furnished with solderless lugs to accommodate copper or aluminum wire, except on 0 Amp size which is provided with / studs. 0- AWG 0 0 Distance in Feet, 0 Volts, 0 Volts, Volts, If the control device does not have adequate current-carrying capacity to control the switch directly, or the control station is to be located a greater distance from the switch than is allowed in the above table, auxiliary control relays for -wire, or -wire control are available. See optional accessories on inside tab.. For 08 volt system, reduce 0 volt values by %.. For volt system, reduce volt values by %. Emerson Network Power. The global leader in enabling Business-Critical ContinuityTM. AC Power Connectivity Embedded Computing Embedded Power Infrastructure Management & Monitoring Outside Plant DC Power Industrial Power Power ing & Controls EmersonNetworkPower.com Precision Cooling Racks & Integrated Cabinets Services Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. 0 Emerson Electric Co. Publication 0 R September, 0 Printed in the U.S.A.

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1 How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module

More information

Transfer switch OTEC and OTECSE open transition

Transfer switch OTEC and OTECSE open transition Specification sheet OTEC and OTECSE open transition 125-600 Amp Description OTEC transfer es are designed for operation and ing of electrical loads between primary power and standby generator sets. They

More information

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches

More information

Low Voltage 480V Switchgear

Low Voltage 480V Switchgear Low Voltage 480V Switchgear General Description Low Voltage metal-enclosed switchgear is used in electric power distribution systems for the control and protection of circuits and equipment. The switchgear

More information

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according

More information

2. Wiring Diagrams: Power, signal, and control wiring. 3. Field quality-control test reports. 4. Operation and maintenance data.

2. Wiring Diagrams: Power, signal, and control wiring. 3. Field quality-control test reports. 4. Operation and maintenance data. SECTION 262416 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes all panelboards. 1.2 SUBMITTALS A. Product Data: For each type of panelboard, overcurrent protective device, accessory, and component

More information

Transfer switch Service Entrance OTEC

Transfer switch Service Entrance OTEC Transfer switch Service Entrance OTEC 40-600 Amp Description Cummins Power Generation s Service Entrance Transfer Switches are designed for operation and switching of electrical loads between primary power

More information

Technical Data and Specifications. Table 12-153. UL 489 Interrupting Capacity Ratings. Number of Poles 2, 3 2, 3, 4 2, 3, 4 2, 3, 4.

Technical Data and Specifications. Table 12-153. UL 489 Interrupting Capacity Ratings. Number of Poles 2, 3 2, 3, 4 2, 3, 4 2, 3, 4. May 8 Typical Circuit Product Description All Eaton s Cutler-Hammer Circuit s are HACR rated. circuit breakers are available as individual components (Frame, Trip Unit, Terminals), or factory assembled

More information

DLA starters General information

DLA starters General information General information The construction of is based on ABB A Line contactors. The mounting plate, including a built-in A contactor, is designed to integrate an ABB manual motor starter type MS325. Starters

More information

ASCO SERIES 185 Power Transfer Switches

ASCO SERIES 185 Power Transfer Switches ASCO SERIES 185 Power Transfer Switches 4-hour protection no matter when trouble strikes ASCO Series 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... Your business or home from

More information

CAT ATC MOLDED CASE CIRCUIT BREAKER AND MOLDED CASE SWITCH AUTOMATIC TRANSFER SWITCH

CAT ATC MOLDED CASE CIRCUIT BREAKER AND MOLDED CASE SWITCH AUTOMATIC TRANSFER SWITCH CAT ATC MOLDED CASE CIRCUIT BREAKER AND MOLDED CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability

More information

SECTION 16425 SWITCHBOARDS. 1. Requirements for main and distribution switchboards.

SECTION 16425 SWITCHBOARDS. 1. Requirements for main and distribution switchboards. SECTION 16425 SWITCHBOARDS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Requirements for main and distribution switchboards. B. Related Sections: 1. Section 16420 - Service Entrance 2. Section 16430

More information

Tmax MCCBs. Molded case circuit breakers. Tmax

Tmax MCCBs. Molded case circuit breakers. Tmax Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high

More information

RPA PROJECT NO SECTION Page 1 of 5 BW&A NO SECTION SWITCHBOARDS

RPA PROJECT NO SECTION Page 1 of 5 BW&A NO SECTION SWITCHBOARDS RPA PROJECT NO. 2015225.00 SECTION 26-24-13 - Page 1 of 5 PART 1 - GENERAL 1.01 DESCRIPTION SECTION 26-24-13 A. All work specified in this Section shall comply with the provisions of Section 26-05-05.

More information

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a

More information

E-Series. Circuit Breaker

E-Series. Circuit Breaker E-Series Circuit Breaker The E-Series hydraulic/magnetic circuit breaker is ideally suited for higher current and voltage applications. It is UL listed and CSA certified for branch circuit protection,

More information

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate: Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,

More information

C. ANSI C Electrical Analog Indicating Instruments. E. ANSI C Guide for Transformer through Fault Duration.

C. ANSI C Electrical Analog Indicating Instruments. E. ANSI C Guide for Transformer through Fault Duration. SECTION 264260 - DISTRIBUTION SWITCHBOARDS PART 1 GENERAL 1.01 SECTION INCLUDES A. Main switchboard. 1.03 RELATED SECTIONS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations Connecting the Power of the Sun DC Disconnects for Solar Photovoltaic Installations DC disconnects for solar photovoltaic installations Solar energy is heating up Interest in renewable energy sources has

More information

Owner s Manual. For Automatic Transfer Switch. 100-200 Amp, Service Entrance/Non-Service Entrance

Owner s Manual. For Automatic Transfer Switch. 100-200 Amp, Service Entrance/Non-Service Entrance Owner s Manual For Automatic Transfer Switch 100-200 Amp, Service Entrance/Non-Service Entrance Model Numbers RTST100A3 RTSP100A3 RTST150A3 RTST200A3 RTSP200A3 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

More information

Table HP 1: AMPERE RATINGS & HORSEPOWER RATING 1 PHASE. Table HP 2: AMPERE RATING & HORSEPOWER RATING 3 PHASE & 2 PHASE - 4 WIRE

Table HP 1: AMPERE RATINGS & HORSEPOWER RATING 1 PHASE. Table HP 2: AMPERE RATING & HORSEPOWER RATING 3 PHASE & 2 PHASE - 4 WIRE Table HP 1: AMPERE RATINGS & HORSEPOWER RATING 1 PHASE FLA & LRC CONVERTED TO TABLE HORSEPOWER (SEE NOTE #2) USE FLA & LRC RATINGS WHERE NO HP RATING IS GIVEN NOMINAL CIRCUIT VOLTAGE V-EA MOTOR MOTOR 110-120

More information

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun DC disconnects for solar photovoltaic installations Connecting the power of the sun Solar energy is heating up Interest in renewable energy sources has never been greater, and the fastest growing of these

More information

CAT ATC CONTACTOR- BASED BYPASS ISOLATION AUTOMATIC TRANSFER SWITCH

CAT ATC CONTACTOR- BASED BYPASS ISOLATION AUTOMATIC TRANSFER SWITCH CAT ATC CONTACTOR- BASED BYPASS ISOLATION AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a

More information

PHYSICAL FACILITIES. 2015 Consultant s Handbook Division 26 ELECTRICAL 2413 SWITCHBOARDS. Page 1 of 11

PHYSICAL FACILITIES. 2015 Consultant s Handbook Division 26 ELECTRICAL 2413 SWITCHBOARDS. Page 1 of 11 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

Power Distribution Catalog

Power Distribution Catalog Power Distribution Catalog Since its founding in 1927 by Peter Mole in Hollywood, Mole-Richardson Co. has focused its research and manufacturing facilities to the production of lighting and power equipment

More information

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2

More information

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to: PREFACE UL developed the Dead-Front Switchboard Marking Guide for code authorities, electric utilities, contractors, installers, users, designers, and other interested parties to aid in understanding deadfront

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

MCC Ratings. Voltage Rating

MCC Ratings. Voltage Rating MCC Ratings In addition to the various ratings of individual components used in motor control centers, the overall ratings of the motor control center must also be considered. Voltage Rating Motor control

More information

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity Proper Application of 415V Systems in North American Data Centers A White Paper from the Experts in Business-Critical Continuity Introduction Increasing pressure to reduce operating expenses and be more

More information

Installation Manual. Innovative marine electrical products Built to last

Installation Manual. Innovative marine electrical products Built to last Innovative marine electrical products Built to last Installation Manual DC Battery Management, DC Branch, AC Main, AC Branch, AC Source Selection, and AC/DC Combination Panels. Table of Contents Specifications

More information

ELECTRICAL ACCEPTANCE TESTS

ELECTRICAL ACCEPTANCE TESTS Scope This guideline defines the standard tests that all electrical systems and equipment must pass prior to final acceptance by the University. These tests are in addition to acceptance tests specified

More information

Table of Contents. Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings. Technical Assistance

Table of Contents. Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings. Technical Assistance Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings Table of Contents Page Selection Table.... 2 Power Distribution Blocks PDBFS Series....................................3-8

More information

Lighting contactors A9 A300

Lighting contactors A9 A300 Lighting contactors Lighting contactors A9 A00 Lighting Features CE mark Compact space saving design Standard auxiliary contact configurations: A9 - A40 1 NO or 1 NC A50 - A110 1 NO & 1 NC Additional

More information

CHAPTER 2 EXAMPLES AND TABLES

CHAPTER 2 EXAMPLES AND TABLES CHAPTER 2 EXAMPLES AND TABLES COMMENTARY AT 210.20(A) EXCEPTION An overcurrent device that supplies continuous and noncontinuous loads must have a rating that is not less than the sum of 100 percent of

More information

Type IP Core and Coil Transformers

Type IP Core and Coil Transformers Type IP Core and Coil Transformers GE Type IP Transformers for Performance, Reliability and Service Life Choosing a brand of dry type core and coil transformer for your electrical equipment is an important

More information

Reed Switch Signal / Electrical Requirements

Reed Switch Signal / Electrical Requirements Reed Switch Signal / Electrical Requirements Reed Switch Application Notes APPLICATION NOTES: Reed Switch Signal / Electrical Requirements Reed switches, though mechanical in nature, ultimately transfer

More information

Spec Setter Safety Switches

Spec Setter Safety Switches GE Electrical Distribution Spec Setter Safety Switches We help you get the job done right! imagination at work General Electric s Spec Setter safety switches are available for all your disconnect needs,

More information

RCP-0006 Through RCP-0042 System Manual

RCP-0006 Through RCP-0042 System Manual Touch-Plate Lighting Controls RCP SERIES RCP Series System Manual RCP-0006 Through RCP-0042 System Manual Touch-Plate Lighting Controls 1830 Wayne Trace Fort Wayne, IN 46803 Phone: 260-424-4323 Fax: 260-420-3651

More information

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No. RFV Key features: Compact and EN compliant RFV force guided relays Force guided contact mechanism (EN00 Type A TÜV approved) Contact configuration -pole (NO-NC, 3NO-NC) 6-pole (NO-NC, NO-NC, 3NO-3NC) Built-in

More information

Catalog January. Heavy industrial power applications Motor contactors and starters

Catalog January. Heavy industrial power applications Motor contactors and starters Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type

More information

Power Supplies 3. SDN-P DIN Rail Series

Power Supplies 3. SDN-P DIN Rail Series SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.

More information

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 Instruction Sheet 1-2003 Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 PURPOSE OF KIT A CCM-T is used to monitor and control an automatic transfer switch. The

More information

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less. PART 1 - GENERAL SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less. RELATED SECTIONS Division 16 Section "Basic Electrical Materials and Methods" for general

More information

Switchboards. Siemens STEP 2000 Course. STEP 2000 Courses distributed by

Switchboards. Siemens STEP 2000 Course. STEP 2000 Courses distributed by Siemens STEP 2000 Course Switchboards It's easy to get in STEP! Download any course. Hint: Make sure you download all parts for each course and the test answer form. Complete each chapter and its review

More information

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80 Buck-Boost Transformers Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...

More information

Table Temperature Correction Factors for Voltage Drop. Conductor Percent Correction Power Factors %

Table Temperature Correction Factors for Voltage Drop. Conductor Percent Correction Power Factors % .-0 January 003 Ref. No. 0054 Tables Note: Busway voltage drop tables are shown in Section 3 of this catalog. Tables for calculating voltage drop for copper and aluminum conductors, in either magnetic

More information

Electrobar 8-Bar Conductor Bar System Application Guide Technical Bulletin #: 8-BAR-1

Electrobar 8-Bar Conductor Bar System Application Guide Technical Bulletin #: 8-BAR-1 Determining the Appropriate System Electrobar 8-Bar Conductor Bar System Technical Bulletin #: 8-BAR-1 The voltage drop should be calculated to determine if the amperage requirements of the system will

More information

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

SECTION A. UL rd Edition (2009 Revision effective 9/29/2009).

SECTION A. UL rd Edition (2009 Revision effective 9/29/2009). SECTION 16289 TRANSIENT VOLTAGE SURGE SUPPRESSION PART 1 - GENERAL 1.1 DESCRIPTION A. This section describes the materials and installation requirements for Surge Protective Devices (SPDs) and includes

More information

Series 95 Switches. UL File No. E101598

Series 95 Switches. UL File No. E101598 Series 95 Switches UL File No. E101598 INSTRUMENT AND CONTRC ONTROL OL s Instrument and Control Switch is a heavy-duty rotary switch that satisfies the most demanding requirements of the industrial control

More information

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

Learning Module 13: Panelboards and Switchboards. 101 Basic Series Learning Module 13: Panelboards and Switchboards 101 Basic Series What You Will Learn We ll step through each of these topics in detail: Introduction 4 Definitions 4 Similarities Between Panelboards and

More information

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case

More information

GROUNDING AND BONDING. Table of Contents. Minimum Size Bonding, Equipment Grounding, Grounding Electrode Conductor Table

GROUNDING AND BONDING. Table of Contents. Minimum Size Bonding, Equipment Grounding, Grounding Electrode Conductor Table GROUNDING AND BONDING Table of Contents Grounding Bonding Minimum Size Bonding, Equipment Grounding, Grounding Electrode Conductor Table Typical Residential Service Grounding and Bonding Drawing (overhead)

More information

SECTION 164XX FUSED MAIN AND DISTRIBUTION SWITCHBOARDS

SECTION 164XX FUSED MAIN AND DISTRIBUTION SWITCHBOARDS SECTION 164XX FUSED MAIN AND DISTRIBUTION SWITCHBOARDS PART 1 GENERAL 1.1 SUMMARY A. Furnish and install main and distribution switchboards as shown on the drawings. Switchboard shall be free-standing,

More information

ZENITH ZTS-MV MEDIUM VOLTAGE TRANSFER SWITCHGEAR

ZENITH ZTS-MV MEDIUM VOLTAGE TRANSFER SWITCHGEAR ZENITH ZTS-MV MEDIUM VOLTAGE TRANSFER SWITCHGEAR 1 RATING 1.1 The automatic switchgear shall be rated for a line voltage of, phase,, wire, Hertz with a maximum ampere rating of, interrupting current rating

More information

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Lighting Packages. 230 VAC Fluorescent Enclosure Light: Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for

More information

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual Infrastructure Management & Monitoring For Business-Critical Continuity Liebert icom-do User Manual TABLE OF CONTENTS 1.0 INTRODUCTION............................... 1 2.0 INSTALLATION...............................

More information

Cable/Conduit Conversion

Cable/Conduit Conversion Cable/Conduit Conversion Busway can be used in many applications where cable and conduit are more commonly used. The question arises, Why use busway instead of conventional cable and conduit? Benefits

More information

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to

More information

Types of Circuit Breakers

Types of Circuit Breakers Types of Circuit Breakers Instantaneous Magnetic- Trip-Only Circuit Breakers Instantaneous magnetic-trip-only circuit breakers do not provide overload protection and are used on motor circuits where overload

More information

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY 7320 Ashcroft, Suite 104 Houston, Texas 77081 p: 713-772-1404 f: 713-772-7360 e: info@juicegoose.com www.juicegoose.com 06-06 CONGRATULATIONS

More information

Bulletin 700-HP PCB Pin Style Relay

Bulletin 700-HP PCB Pin Style Relay Bulletin 700-HP PCB Pin Style Relay Bulletin 700 HP (PCB) "Pin Style Relay 8 A contact ratings DPDT/ (2 c/o) contacts Plug-in PIN style (PCB) terminals (5 mm pinning) Choice of standard silver nickel contacts,

More information

SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS

SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated

More information

PREFACE. The products covered by this Guide are:

PREFACE. The products covered by this Guide are: PREFACE UL has developed the Molded-Case Circuit Breaker (MCCB) Marking Guide for code authorities, electric utilities, contractors, installers, users, designers, and other interested parties to aid in

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

SOLAR PHOTOVOLTAIC (PV) SYSTEMS ELECTRICAL CODE COMPLIANCE AND INSPECTION CHECKLIST

SOLAR PHOTOVOLTAIC (PV) SYSTEMS ELECTRICAL CODE COMPLIANCE AND INSPECTION CHECKLIST SOLAR PHOTOVOLTAIC (PV) SYSTEMS ELECTRICAL CODE COMPLIANCE AND INSPECTION CHECKLIST This checklist contains common electrical code requirements for PV systems, based on the 2008 National Electrical Code

More information

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE 2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE PAGE 1 OF 5 This Reference provides a very comprehensive list of aspects of a solar PV installation that could be reviewed, clarifying

More information

T M. User Manual. LifeGuard. Ground Fault Circuit Interrupters (GFCI)

T M. User Manual. LifeGuard. Ground Fault Circuit Interrupters (GFCI) T M User Manual LifeGuard Ground Fault Circuit Interrupters (GFCI) NAE1085011 / 02.2014 T M USA: Bender Inc. :420 Eagleview Blvd. Exton, PA 19341 Toll-Free: 800-356-4266 Phone: 610-383-9200 Fax: 610-466-2071

More information

DIN RAIL MOUNTED INDUSTRIAL DC UPS OPTIMIZING UPTIME.

DIN RAIL MOUNTED INDUSTRIAL DC UPS OPTIMIZING UPTIME. DIN RAIL MOUNTED INDUSTRIAL DC UPS OPTIMIZING UPTIME. PROTECT SENSITIVE COMPUTER AND MANUFACTURING OPERATIONS WITH AN UNINTERRUPTiBLE DC POWER SUPPLY. The SDU DIN Rail DC UPS is the only choice for the

More information

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

What are the basic electrical safety issues and remedies in solar photovoltaic installations? What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety Topics Covered Photovoltaic

More information

GTEC transfer switch open transition

GTEC transfer switch open transition GTEC transfer switch open transition 40-1250 Amp Description The GTEC automatic transfer switch combines reliability and flexibility in a small, economical package for transferring loads between a utility

More information

BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES

BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES The Edison British Style semiconductor protection fuses include a 660VAC line utilizing new filler technology. These new fuses have greatly reduced peak let-through current and energy under fault conditions

More information

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D 12 - ELECTRIC SERVICE HANDBOOK SECTION D METER REQUIREMENTS This chapter gives you information on Central Lincoln s metering requirements. It's divided into three sections: General requirements This section

More information

NEC 2014 Code Changes

NEC 2014 Code Changes NEC 2014 Code Changes Articles 400-408.55 CHANGES FROM 2011 TO 2014 CODE ARE IN RED Chapter 4 Equipment for General Use ARTICLE 400 Flexible Cords and Cables 400.4 Types Flexible cords and flexible cables

More information

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services Circuit Breakers and Switchgear Thomas Greer Director of Engineering TLG Services Presentation Outline Switchgear Definition Overcurrent Protection Devices Circuit Breaker Trip Curves and Coordination

More information

Contactors Low Voltage

Contactors Low Voltage 00Motor Starters and April 06 Sheet Motor Starters and ContactorsLow Voltage.0- ContactorsLow Voltage Contents Motor Starters and ContactorsLow Voltage Manual Motor Control MS Starter with Hand/Auto......................................-

More information

n Choice of equipment SP 58 Index of protection: IP 2X - IP 2XC - under front plate

n Choice of equipment SP 58 Index of protection: IP 2X - IP 2XC - under front plate SP fuse carriers with protected terminals SP fuse carriers with protected terminals www.klinkmann.com n Choice of equipment Maximum cartridge rating Type Rated current 400 V± 0 V± 690 V± gg am gg am gg

More information

Industrial Control Relays Type X

Industrial Control Relays Type X X CATALOG CONTENTS Description.................................................... Page General......................................................... -3 Accessories.......................................................

More information

Installation Manual Series, 7ATS, 7ACTS, 7ADTS G, Q, S, & U design Automatic Transfer Switches. Installation A DANGER

Installation Manual Series, 7ATS, 7ACTS, 7ADTS G, Q, S, & U design Automatic Transfer Switches. Installation A DANGER Installation Manual Installation Manual ASCO 7ATS, 7ACTS, 7ADTS 7000 Series, 7ATS, 7ACTS, 7ADTS G, Q, S, & U design Automatic Transfer Switches DANGER is used in this manual to warn of a hazard situation

More information

DC Loop Contactors, Contactor Lugs and Dynamic Brakes Technical Data

DC Loop Contactors, Contactor Lugs and Dynamic Brakes Technical Data DC Loop Contactors, Contactor Lugs and Dynamic Brakes Technical Data Table of Contents 1370 DC Loop Contactors....................................3 Catalog Number Explanation...............................3

More information

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140)

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140) 9-10N Supersedes Selection Data 9-10N, pages, 1-, dated dated March March 1995 1995 Mailed to: E, D, C/9-100A, 31-A, INTERRUPTING CAPACITY RATINGS IEC 947- Interrupting Capacity s➀ Interrupting Capacity

More information

Sentron Series Circuit Breakers

Sentron Series Circuit Breakers Sentron Series Circuit Breakers Siemens Sentron Series circuit breakers are available in nine frame sizes: ED, FD, JD, LD, LMD, MD, ND, PD, and RD. Sentron Series circuit breakers have a wide range of

More information

AE8-1328 R5 March 2011. Copeland Digital Compressor Controller AE8-1328 R5. Specifications

AE8-1328 R5 March 2011. Copeland Digital Compressor Controller AE8-1328 R5. Specifications AE8-1328 R5 March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the Copeland

More information

Transfer switch BTPC open, closed or delayed transition

Transfer switch BTPC open, closed or delayed transition Transfer switch BTPC open, closed or delayed transition 150-4000 Amp Description The Cummins Power Generation BTPC series bypass isolation transfer switch combines an automatic transfer switch with a drawout

More information

GTEC Transfer switch open transition

GTEC Transfer switch open transition GTEC Transfer switch open transition 40 2000 amp Description GTEC transfer switches combine reliability and flexibility in a small, economical package for transferring loads between a utility and a generator

More information

Circuit Breakers Supplementary Protectors Manual Motor Controllers

Circuit Breakers Supplementary Protectors Manual Motor Controllers WHITE PAPER Circuit Breakers Supplementary Protectors Manual Motor Controllers Circuit Protection Methods Differentiating between Supplementary Protection, Branch Circuit Protection, and Self-Protected

More information

Section 14. Transformers Open Core and Coil Transformers Machine Tool and Control Power. Control Catalog 14-1

Section 14. Transformers Open Core and Coil Transformers Machine Tool and Control Power.  Control Catalog 14-1 Machine Tool and Control Power Description Type IP transformers are core and coil units designed for machine tool, industrial control, panelboard, and general-purpose applications. These designs are now

More information

NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Major Power Users

NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Major Power Users NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Major Power Users A White Paper from the Experts in Business-Critical Continuity TM Executive Summary Electrocutions are the fourth

More information

SPR-5200 and SPR-4600 Installation and Operation Manual

SPR-5200 and SPR-4600 Installation and Operation Manual SPR-5200 and SPR-4600 Installation and Operation Manual SunPower Corporation Document # 001 69178 Rev** 1 SunPower Inverter SPR-5200 and SPR-4600 Table of Contents SunPower Corporation Document # 001 69178

More information

A. Extent of switchboard work is indicated by Drawings and/or by requirements of this Section.

A. Extent of switchboard work is indicated by Drawings and/or by requirements of this Section. SECTION 262413 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

ABB LV Product Overview Capabilities Guide

ABB LV Product Overview Capabilities Guide ABB LV Product Overview Capabilities Guide Breakers and Switches Disconnects ABB has a wide portfolio of low voltage switches that include: fusible, non-fusible, change-over, enclosed and cam switches

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables The National Armored Cable Manufacturers Association Presents Installation Standard for Types AC and MC Cables An ANSI Standard Original document jointly produced by NECA and NACMA as Standard for Installing

More information

LOW VOLTAGE FRONT ACCESSIBLE MAIN SWITCHBOARD

LOW VOLTAGE FRONT ACCESSIBLE MAIN SWITCHBOARD SECTION 16323 LOW VOLTAGE FRONT ACCESSIBLE MAIN SWITCHBOARD PART 1 - GENERAL 1.01 General: Provide low voltage main switchboard, complete, as indicated, specified and required per Contract Documents. 1.02

More information

SECTION (16289) - SURGE PROTECTION FOR LOW VOLTAGE ELECTRICAL POWER CIRCUITS

SECTION (16289) - SURGE PROTECTION FOR LOW VOLTAGE ELECTRICAL POWER CIRCUITS SECTION 26 43 13 (16289) - SURGE PROTECTION FOR LOW VOLTAGE ELECTRICAL POWER CIRCUITS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Transient Voltage Surge Suppressors for Low-Voltage Power, Control,

More information

Safety Requirements for Power Supplies Intended for Medical Applications

Safety Requirements for Power Supplies Intended for Medical Applications Safety Requirements for Power Supplies Intended for Medical Applications Disclaimer: Emerson does not warrant the accuracy or completeness of this article, including but not limited to, the reliability

More information

LOAD BANK PART NUMBER / OPERATIONS AND MAINTENANCE MANUAL

LOAD BANK PART NUMBER / OPERATIONS AND MAINTENANCE MANUAL LOAD BANK PART NUMBER 2004297/2004298 OPERATIONS AND MAINTENANCE MANUAL Prepared by: 5455 N River RD W Geneva, OH 44041 Phone: 1-800-969-8527 TechSupport@get-psi.com HDT 1 TM-2004297/2004298 TABLE OF CONTENTS

More information

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary

More information