1 Model 000 Remote Reset Meter Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET... METHOD OF OPERATION... GENERAL INSTALLATION AND START-UP INSTRUCTIONS... 0 AND 0 TIMER SETTINGS... REGENERATION PULSE SETTING PROCEDURE... DOME AND IMPELLER REPLACEMENT PROCEDURE... 0 DELAYED REGENERATION TIMER ASSEMBLY... 0 IMMEDIATE REGENERATION TIMER ASSEMBLY... REMOTE METER W/ENVIRONMENTAL COVER...7 " METER ASSEMBLY...8 -/" METER ASSEMBLY...9 " BRASS METER ASSEMBLY...0 " METER ASSEMBLY... " METER ASSEMBLY... DIMENSION DRAWINGS... ENGINEERING DRAWINGS... REMOTE METER WIRING... SERVICE ASSEMBLIES...7 TROUBLESHOOTING...8 JOB SPECIFICATION SHEET Job No. Meter Model No. Pipe Size Inlet To Softener Outlet To Feed Lines Estimated Or Measured Flow Rate Min. Gpm Estimated Or Measured Flow Rate Max. Gpm Type Of Reset Meter a. Immediate Pulse ( Minute Reset) b. Delayed Pulse (Factory :00 A.M. with 0 Minute Pulse) Meter Gallon Range a. " Remote Meter Standard Range 0 Gallon Min.,70 Gallon Max. Extended Range,0 Gallon Min.,0 Gallon Max. b. -/" Remote Meter Standard Range Gallon Min. 0, Gallon Max. Extended Range, Gallon Min., Gallon Max. c. " Remote Meter Standard Range,0 Gallon Min.,0 Gallon Max. Extended Range,0 Gallon Min. 0,0 Gallon Max. d. " Remote Meter Standard Range,70 Gallon Min.,70 Gallon Max. Extended Range 8,70 Gallon min. 8,70 Gallon Max. Meter Gallons Reserve Gallons For Delayed Pulse Meters Gallons METHOD OF OPERATION " Meter Monitors Outlet Service Flow Figure Model 0 Timer Immediate Regeneration The Econominder answers today s commercial/industrial water conservation needs by saving water, salt and sewer use tax. The Econominder mechanical meter monitors the soft water service flow at the control outlet with the meter impeller being the only instream moving part. As the turbine turns, its rotation drives a water lubricated gear train in the dome of the meter. As the output shaft at the top of the meter rotates, the cable connection to the timer clutch assembly turns the meter program wheel on the face of the timer counterclockwise until it reaches the regeneration stop position. Regeneration may occur immediately or on a delayed basis depending upon system requirements. GENERAL INSTALLATION AND START-UP INSTRUCTIONS Flow Range " Remote Meter 0.7 gpm to 0 gpm. -/" Remote Meter. gpm to 7 gpm. " Remote Meter gpm to 0 gpm. " Remote Meter 7 gpm to 00 gpm % registration accuracy over these flow ranges. Electrical Meter and control valve operating voltages must match. CAUTION: Water pressure is not to exceed 0 psi, water temperature is not to exceed 0 or 0 F with hot water package, and meter cannot be exposed to freezing conditions. 9 Rev C SE0

2 GENERAL INSTALLATION AND START-UP INSTRUCTIONS continued Installation Instructions. All plumbing shall be done in accordance with local plumbing codes. The meters are to be installed on soft water outlets. Twin units with () one meter shall be installed on the common soft water outlet of the units. NOTE: Arrow on brass casting indicates direction of water flow.. All water lines should be flushed prior to meter installation.. For ease of service, a union should be installed on the outlet of the meter. The inlet has its own built-in union.. Meter bodies must be installed the horizontal position with the reset timer assemblies in the vertical position. See Figure and Figure. Meter Body Front View. All electrical connections must be made in accordance to local codes. Follow control valve manufacturer s wiring schematic.. Once pressurized check for leaks. Use meter checker (enclosed in package) to check operation. See Figure and Figure. Test Dial Meter Dome Meter Cable Clear Plastic Indicator Figure Clear Plastic Indicator Gallon Markings Direction of Flow Meter Reset Timer Assembly Figure Meter Dome Figure a. Pull cable out of meter dome. b. Place test dial over protruding hub on meter dome. c. Push brass cable fitting into split hole in clear plastic indicator (ribbed side up). d. Push cable into socket in meter dome. e. Rotate clear plastic indicator counter clockwise until line is at desired start point. f. The numbers will count up from zero. Draw a measured volume of water or time a desired flow rate. The clear plastic indicator hair line should read the appropriate gallons on the test dial. Figure NOTE: If Meter Reset Timer Assembly must be located on the opposite side of meter body, use bracket PN 9 or 7. See Figure. Extended Range Cap Should be in Position Shown Timer Reverse Mounting Position Reverse Mounting Bracket P/N 9 (" Remote) P/N 7 (" Remote) " Meter Timer STD. Mounting Position Figure 7 Figure CAUTION: Always remove meter cable from dome only. Do not remove from meter reset timer assembly. SE0 Model 000 Remote Reset Meter

3 GENERAL INSTALLATION AND START-UP INSTRUCTIONS continued Extended Range Cap Should be in Position Shown " and." Meter Extended Range Cap Should be in Position Shown Meter Cable Length = -/" = -/8" 79 = 7-/" 90 = -/" 0 = 8-/" Timer Reverse Mounting Position Timer STD. Mounting Position Figure 8 Figure 9 " Meter Meter Cable P/N Mechanical RM Std. Range Ext. Range " Std. Mount " Rev. Mount 90." Std. Mount." Rev. Mount " Std. Mount " Rev. Mount " Plastic Std. Mount 0 0 " Plastic Rev. Mount " Std. Mount " Rev. Mount Spare cable sent to allow change in orientation of remote meter. *" and " Ext meter gets cable. 0 AND 0 TIMER SETTINGS Typical Programming Procedure Calculate the gallon capacity of the system, subtract the necessary reserve requirement and set the gallons available opposite the small white dot on the program wheel gear (Figure 0). NOTE: Figure 0 shows 8,70 gallon setting. The capacity (gallons) arrow () shows zero gallons remaining. The unit will regenerate tonight at the set regeneration time. How To Set The Time Of Day:. Press and hold the red time set button in to disengage the drive gear.. Turn the large gear until the actual time of day is opposite the time of day pointer.. Release the red button to again engage the drive gear. How To Manually Regenerate Your Remote Meter:. Turn the manual regeneration knob clockwise.. This slight movement of the manual regeneration knob engages the program wheel and starts the regeneration signal.. The black center knob will make one revolution: Delayed Regeneration - hrs Immediate Regeneration - min Immediate Regeneration Timers: These timers do not have a hour gear. Setting the gallons on the program wheel and manual regeneration procedure are the same as previous instructions. The timer will regenerate as soon as the capacity gallons reaches zero. NOTE: The program wheel to the left may be different than the program wheel on the product. NOTE: To set meter capacity rotate manual knob one - 0 revolution to set gallonage. Figure 0 Model 000 Remote Reset Meter SE0

4 REGENERATION PULSE SETTING PROCEDURE Delayed Regeneration (See Figure ) Signal Section Minimum Setting ( Min. per Pin) Pins = Mins. Preset Pins = Mins. Total Reset Time Hours NOTE: Regeneration can be done from remote meter with proper program wheel setting. Immediate Regeneration (See Figure ) Total reset time Min. Signal (fixed) Min. Pin Storage DOME AND IMPELLER REPLACEMENT PROCEDURE To replace the meter dome and impeller:. Turn off water supply and remove pressure from pipes.. Remove cover bolts.. Remove meter dome assembly. Meter dome can be rotated 0 to help loosen O-ring seal.. Inspect impeller for foreign material. Clean or replace. If the meter is defective, replace entire assembly. DO NOT attempt to remove gear box cover plate.. Lubricate meter dome O-ring with silicone lubricant and place on dome assembly.. Place impeller on impeller shaft. 7. Place meter dome on top of meter assembly, making sure the impeller slips into body bearing. 8. Replace and tighten cover bolts. Meter Dome Assembly Meter Dome O-ring Switch Arm Impeller Timer swings to this side. Brass Meter Body Direction of Flow Figure Figure Meter Body Bearing Switch Arm Timer swings to this side. Figure The regeneration signal on Delayed Regeneration timers (Figure ) is pre-set for mins. This setting should not be changed. Immediate Regeneration units Figure have a fixed min. signal and reset time; no adjustments can be made unless optional 80 min. program is used. SE0 Model 000 Remote Reset Meter

5 0 DELAYED REGENERATION TIMER ASSEMBLY BR0-0 Rev A Item No. QTY Part No. Description Housing, Timer Gear, Cycle Actuator Dial AM Regen Assy, Black Knob, Screw, Hex wsh, -0 x / Label, Button Program Wheel, w/" Std Label Retainer, Program Wheel Screw, Flt Hd St, -0 x / Spring Clip Pinion, Idler Idler Shaft Spring Gear, Idler Drive Gear Plate, Motor Mounting Motor, 0V-0Hz, /0 rpm Motor, 00V-0Hz, /0 rpm Motor, V-0Hz, /0 rpm Motor, V-0Hz, /0 rpm Motor, V-0Hz, /0 rpm Motor, 0V-0Hz, /0 rpm Screw, Sltd Fillster Hd Program Wheel Drive Pinion Clutch, Drive Pinion Item No. QTY Part No. Description Meter Clutch Spring Retainer, Clutch Spring Screw, Phil, - x / Zinc Bracket, Hinge Timer Insulator Micro Switch Switch, Micro, Timer Screw, Pan Hd Mach, -0 x / Label, Indicator Label, Caution Label, Instruction Harness, 0, Delayed Nut, Wire, Tan Wire, Ground, " Program Wheel Assy, 9000 / Main Drive Gear Terminal Strip Label, Terminal Strip Label, Time of Day Spring, Detent /" Ball Pin, Spring, / x /8 SS, Timer Model 000 Remote Reset Meter SE0

6 0 IMMEDIATE REGENERATION TIMER ASSEMBLY BR0-0M Rev A Item No. QTY Part No. Description Housing Timer Gear, Cycle Actuator SYS # Knob, Screw, Hex WSH, -0 x / Label, Button Program Wheel, w/" STD Label Retainer, Program Wheel Crew, FLT HD ST, -0 x / Spring Clip Pinion, Idler Idler Shaft Spring Gear, Idler Drive Gear Plate, Motor Mounting Motor, Drive, 0V, 0 Hz, rpm......motor, 0V, 0 Hz rpm Motor, V, 0 Hz rpm Screw, SLTD FILLISTER HD Pinion, Program Wheel Item No. QTY Part No. Description Clutch, Drive Pinion Meter Clutch Spring Retainer, Clutch Spring Screw, PHIL, - x / Zinc Bracket, Hinge Timer Insulator Switch, Micro Micro Switch Screw, Pan HD Mach, -0 x / Label, Indicator Label, Caution Label, Instruction Wire, Ground, " Program Wheel BR0...Gear, Main Drive Harness, 0, Immediate Terminal Strip Label, Terminal Strip SE0 Model 000 Remote Reset Meter

7 REMOTE METER W/ENVIRONMENTAL COVER Rev A Item No. QTY Part No. Description Cover, Head Screw, Plastic Seal,. dia Window Screw, #-0 x 7/" Seal,. dia Cover Assy, Remote, Black, Items,,,,, and Hinged Pin Tapered Cap Backplate, Specify System/Timer Screw, #8- x /" Screw, #-0 x /8" Terminal Strip (-Position Gray) Nut, # Fitting, Liquid Tight Label, Terminal Strip Label, Warning Model 000 Remote Reset Meter SE0 7

8 " METER ASSEMBLY A B Rev D Item No. QTY Part No. Description Meter Body Post A Impeller B Impeller, HW O-ring - Meter Cover A Meter Cap Assy, Std, Plastic Meter Cap Assy, Std, Brass, Hot Water B Meter Cap Assy, Ext, Plastic Meter Cap Assy, Ext, Brass, Hot Water A Screw, Plastic Meter Cap Assy B Screw - Brass Meter Cover Flow Straightner O-ring - Quick Connect Nipple - Quick Connect Nut - Quick Connect Reverse Mounting Bracket (Optional as needed) 8 SE0 Model 000 Remote Reset Meter

9 -/" METER ASSEMBLY A B Rev C Item No. QTY Part No. Description Meter Body Post A Impeller B Impeller, HW O-ring - Meter Cover A Meter Cap Assy, Std, Plastic Meter Cap Assy, Std, Brass, Hot Water B Meter Cap Assy, Ext, Plastic Meter Cap Assy, Ext, Brass, Hot Water A Screw, Plastic Meter Cap Assy B Screw - Brass Meter Cover Flow Straightner O-ring Nipple - Quick Connect Nut - Quick Connect Reverse Mounting Bracket Model 000 Remote Reset Meter SE0 9

10 " BRASS METER ASSEMBLY Rev E Item No. QTY Part No. Description Meter Body Impeller Shaft Retainer Impeller Shaft Reverse Mounting Bracket (Optional as needed) Impeller O-ring - Meter Cover Meter Cap Assy, Std, Plastic Screw, Plastic Meter Cap Assy O-ring - Quick Connect Nipple - Quick Connect Flow Straightener Nut - Quick Connect Not Shown Meter Cap Assy, Ext, Plastic 0 SE0 Model 000 Remote Reset Meter

11 " METER ASSEMBLY 8 7B 7A _REVB 0 Rev B Item No. QTY Part No. Description Body, Meter, " Plastic w/ Impeller Shaft Seat Seat, Impeller Shaft, Hex Shaft, Impeller, Stainless Steel Impeller Assy, " Meter O-ring, - 7, Std/0CD, Meter 7A Meter Cap Assy, Std, Plastic 7B Meter Cap Assy, Ext, Plastic Screw, Hex Wsh, 0- x /8 8-8 Stainless Steel Seal, Face, ", Plastic Meter Fitting, Nipple, ", Plastic, NPT, Machined, Flow Straightener Fitting, Nipple, ", Plastic, BSP, Machined, Flow Straightener Fitting, Nipple, ", Brass Fitting, Nipple, ", Plastic, NPT Fitting, Nipple, ", Plastic, BSP Fitting, Nipple, ", Brass Flow Straightener Nut, " Meter Model 000 Remote Reset Meter SE0

12 " METER ASSEMBLY Rev F Item No. QTY Part No. Description Body, Meter, 900, NPT Body, Meter, 900, Metric Impeller Shaft Impeller Assembly Meter Cover Assembly - Std Meter Cover Assembly - Ext. Range O-ring Screw - Hex Hd Flow Straightener Adapter, Flange, ", NPT Adapter, Flange, ", BSP Screw - Hex. Hd Nut - / Washer, Thrust SE0 Model 000 Remote Reset Meter

13 DIMENSION DRAWINGS Meter Assy, " MECH Meter Assy, " MECH [mm] 7..8 [mm] 8.7. Extended Range Extended Range Standard Range 00-09LNE Rev A Standard Range 00-09LNE Rev A " Brass Mechanical Meter and Flow/Pressure Loss Data Standard Range: 0 gal. minimum to,70 gal. max. Extended Range:,0 gal. minimum to,0 gal. max. Flow Accuracy: ±% 0.7 to 0 gpm Meter Assy, /" MECH " Brass and Plastic Mechanical Meter and Flow/Pressure Loss Data Standard Range:,0 gal. minimum to,0 gal. max. Extended Range:,0 gal. minimum to 0,0 gal. max. Flow Accuracy: ±% to 0 gpm Meter Assy, " MECH [mm] [mm] 9..8 Extended Range Extended Range Standard Range Standard Range LNE Rev A 00-00LNE Rev A -/" Brass Mechanical Meter and Flow/Pressure Loss Data Standard Range: gal. minimum to 0, gal. max. Extended Range:, gal. minimum to, gal. max. Flow Accuracy: ±%. to 7 gpm " Brass Mechanical Meter and Flow/Pressure Loss Data Standard Range:,70 gal. minimum to,70 gal. max. Extended Range: 8,70 gal. minimum to 8,70 gal. max. Flow Accuracy: ±% 7 to 00 gpm Model 000 Remote Reset Meter SE0

14 ENGINEERING DRAWINGS Line Drawing, Meter Assy, " Plastic with Plastic Nipples [mm] HEX " NPT OR " BSP THREADS BOTH ENDS. PLASTIC 00-00LNE Rev A Line Drawing, Meter Assy, " Plastic with Brass Nipples [mm] HEX " NPT OR " BSP THREAD BOTHENDS. BRASS 00-00LNE Rev A SE0 Model 000 Remote Reset Meter

15 REMOTE METER WIRING Immediate Regeneration Internal Wiring For Time Clock override, a - minute signal to terminal will reset the Meter. NOTE: See wiring diagram enclosed with valve for proper meter to valve wiring. TB WHITE TB WHITE BLUE BLUE RED RED YELLOW YELLOW BROWN BROWN Delayed Regeneration Internal Wiring TB WHITE BLUE RED YELLOW BROWN BLUE RED BROWN YELLOW TM C N.O. N.C. SW THCAM C N.O. N.C. RED BROWN YELLOW BLUE RED BROWN YELLOW TM C N.O. N.C. SW THCAM C N.O. N.C. TM SW RSCAM C SW N.O. N.C. THCAM C N.O. N.C. SW RSCAM Rev D SW RSCAM Rev D Model 000 Remote Reset Meter SE0

16 REMOTE METER WIRING continued Wiring Diagrams, Sys 7 Multi, Remote Meter ORANGE GREEN BLUE VIOLET BLUE WHITE ORANGE PINK INTERLOCK CABLE RECEPTICLE TB WHITE(BLUE) WHITE METER IMMEDIATE REGENERATION TIMER (BROWN) BROWN GR/YEL GREEN C C N.O. N.C. N.O. N.C. BROWN TM SW THCAM SW RSCAM 9 Rev F SE0 Model 000 Remote Reset Meter

17 SERVICE ASSEMBLIES Back Plates: Backplate, Hinged Backplate, Hinged, w/9 Pin Backplate, Hinged, Remote Meter 00 Timer-Mechanical Backplate, Hinged, Remote Meter Covers: Cover Assy, Environmental Gallon Wheel Assemblies: /" Ext Range (0-0,000) " Std Range (0-,000) " Ext Range (0-,000) " Std Range (0-0,000) " Ext Range (0-0,000) " Std Range (0-,000) " Ext Range (0-00,000) " Std Range (0-0,000) " Ext Range (0-00,000) Meter Assemblies 09...Meter Assy, Meter Assy, 70, " Ext Meter Assy, 80/900,." Std Meter Assy, 80/900,." Ext Meter Assy,.", Std, Brass, Metric Meter Assy,.", Ext, Brass, Metric 09...Meter Assy, 900, " Std Meter Assy, ", Std, Brass, Metric 09...Meter Assy, 900, " Ext Meter Assy, ", Ext, Brass, Metric " 900 Meter Assy, Std Range " 900 Meter Assy, Ext Range Meter Assy, ", Std, Brass, Metric Meter Assy, ", Ext, Brass, Metric 00...Meter Assy, ", Plastic, Std Meter Assy, ", Plastic, Std, Plastic w/brass Nipples 0...Meter Assy, ", Plastic, Ext, Plastic w/plastic Nipples Meter Assy, ", Ext, Plastic w/brass Nipples Meter Cables: Std Ext " Std Mount " Rev Mount " Std Mount " Rev Mount " Std Mount " Rev Mount " Plastic Std Mount " Plastic Rev Mount " Std Mount " Rev Mount Spare cable sent to allow change in orientation of remote meter. *Ext meter gets cable. Meter Caps: 08...Meter Cap Assy,.7" to ", Plastic, Std 0...Meter Cap Assy,.7" to ", Plastic, Ext 8...Meter Cap Assy,.7" to ", Brass, Std 7...Meter Cap Assy,.7" to ", Brass, Ext 00...Meter Cap Assy, ", Brass, Std 0...Meter Cap Assy, ", Brass, Ext Meter Checker Kits 00...Meter Checker Kit,.7" to ", Std Range 0...Meter Checker Kit,.7" to ", Ext Range 0...Meter Checker Kit, " Std & Ext Range 0...Meter Checker Kit,.7 to ", Std & Ext.. Range Combined Timer Assemblies: 0 Configured...Remote Meter Immediate 0 Configured...Remote Meter Delay Model 000 Remote Reset Meter SE0 7

18 TROUBLESHOOTING Issue Possible Cause Corrective Action No gallon registration on meter. Deffective gear box in dome. Check with meter checker. Replace dome assembly. No pulse from meter unit. Stuck impeller due to foreign material, pipe dope, flux, etc, causing the impeller not to rotate. Meter cable not inserted in meter dome or in meter reset timer. Low flows: Less than 0.7 gpm for " Less than. gpm for." Less than.0 gpm for " Less than 7.0 gpm for " Improper installation. No power to meter (test terminals & - should read line voltage). Deflective switch Deflective reset motor. Check with meter checker. Remove and clean impeller. Insert meter cable in dome and meter reset timer. Consult factory. See installation section. Check wiring to meter. Check wiring at control valve. Immediate pulse models replace switch P/N 0-80 &90 min., min. Delayed pulse models replace switch P/N 0 Replace motor. Extended or continuous pulse. Defective reset motor. Replace reset motor. Softener running into hard water before meter sends pulse. Defective pulse switch. Capacity of softener not set-up properly. Incorrect gallon setting. Not enough reserve capacity for Delayed Pulse meter. Low flows: Less than 0.7 gpm for " Less than. gpm for. Less than.0 gpm for " Less than 7.0 gpm for " Immediate pulse models replace switch P/N 0-80 &90 min., min. Delayed pulse models replace switch P/N 0 Readjust salt settings for proper capacity. See softener mfg. set-up instructions. Check raw water hardness and unit capacity recalculate gallons. Adjust meter setting to a lower gallon setting. Consult factory. 8 SE0 Model 000 Remote Reset Meter

19 Model 000 Remote Reset Meter SE0 9

20 00 Pentair Residential Filtration, LLC 9 Rev. C SE0

MODEL 9000. Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.

MODEL 9000. Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference. MODEL 9000 Service Manual IMPORTANT: Fill in pertinent information on page for future reference. Job Specification Sheet * JOB NO. * MODEL NO. * WATER TEST * CAPACITY PER UNIT MAX. PER REGENERATION * MINERAL

More information

Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4

More information

Model 9000/9100/9500 Service Manual

Model 9000/9100/9500 Service Manual Service Manual IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specifications Sheet..................................................................... 3

More information

MODEL 2510 & 2510 ECONOMINDER

MODEL 2510 & 2510 ECONOMINDER ients wd MODEL 2510 & 2510 ECONOMINDER Service Manual IMPORTANT: Fill in pertinent information on page 3 for future reference. main head MODEL 2510 & 2510 ECONOMINDER job specification sheet JOB NO. *MODEL

More information

MODEL 9500. Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.

MODEL 9500. Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference. MODEL 9500 Service Manual IMPORTANT: Fill in pertinent information on page 2 for future reference. Job Specification Sheet JOB NO. MODEL NO. WATER TEST CAPACITY PER UNIT MAX. PER REGENERATION MINERAL TANK

More information

Softener Owners Manual

Softener Owners Manual Softener Owners Manual Models PS 0840 Timer PS 1040 Timer PS 1054 Timer PS 0840 Metered PS 1040 Metered PS 1054 Metered PS 0840x Timer PS 1040x Timer PS 1054x Timer PS 1353x Timer PS 0840x Metered PS 1040x

More information

MODEL 5600 & 5600 ECONOMINDER

MODEL 5600 & 5600 ECONOMINDER Service Manual IMPORTANT: Fill in pertinent information on page 2 for future reference. Job Specification Sheet JOB NO. *MODEL NO. WATER TEST CAPACITY PER UNIT MAX. PER REGENERATION MINERAL TANK SIZE DIA.

More information

Model 5600 & 5600 Econominder

Model 5600 & 5600 Econominder Model 5600 & 5600 Econominder Service Manual IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specification Sheet.........................................................................

More information

Model 5600SE Downflow

Model 5600SE Downflow Service Manual IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specification Sheet...................................................................................

More information

RICAMBI FLECK WATERBOOK 2006-2007 - LISTINO GENERALE

RICAMBI FLECK WATERBOOK 2006-2007 - LISTINO GENERALE RICAMBI FLECK P/N 0 O'ring 560 CD 0 P/N 050 Grommet pass rod 20 2300/230/ 2350 P/N 060 Tube 3/8in (0,92 m) 0 P/N 086 Holding Nut M5 2300 0 P/N 0209-0 Quad Ring 560 CD 0 P/N 028 Microswitch 5 P/N 0220 Screw

More information

Model 5600 & 5600 Econominder

Model 5600 & 5600 Econominder Service Manual IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specification Sheet...................................................................................

More information

Model 6600 Downflow. Service Manual. IMPORTANT: Fill in pertinent information on page 3 for future reference.

Model 6600 Downflow. Service Manual. IMPORTANT: Fill in pertinent information on page 3 for future reference. Service Manual IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specification Sheet...................................................................................

More information

Fleck Model 9000/9100/9500

Fleck Model 9000/9100/9500 Fleck Model 9000/9100/9500 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 EQUIPMENT CONFIGURATION...1 INSTALLATION & START-UP...2 9000/9100/9500 (3200 SERIES) ELECTRO MECHANICAL TIMER ASSEMBLY...5

More information

Filter Owners Manual Models

Filter Owners Manual Models Filter Owners Manual Models PF 0840cb PF 0840n PF 0840m PF 1040cb PF 1040n PF 1040m PF 1240cb PF 1240n PF 1240m PF 1354e Rev. 04/2010 Page 2 Product No. 13130A Table of Contents Product Line Overview Page

More information

Model 7000 Service Manual

Model 7000 Service Manual Service Manual IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specifications Sheet..................................................................... 3

More information

3200ET Remote Meter. Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.

3200ET Remote Meter. Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference. Service Manual IMPORTANT: Fill in pertinent information on page 2 for future reference. Installation and Start-Up Procedures Record Remote Meter Programming Here: Water Hardness System Capacity Regeneration

More information

Form No Parts List for: MODEL C ELECTRIC HYDRAULIC PUMP. To Parts List. Motor Control Assemblies See sheets 6, 7, & 8 of 9

Form No Parts List for: MODEL C ELECTRIC HYDRAULIC PUMP. To Parts List. Motor Control Assemblies See sheets 6, 7, & 8 of 9 Parts List for: Form No. 05 PE55-E0 PE55-E0 PE55A-E0 PE55A-E0 PE55S-E0 PE55S-E0 PE55-E0 PE55-E0 PE55S-E0 PE55S-E0 MODEL C ELECTRIC HYDRAULIC PUMP 5 To Parts List 9 Motor Control Assemblies See sheets,,

More information

TABLE OF CONTENTS. General Warnings Installation Programming System Start-Up Frequently Asked Questions...

TABLE OF CONTENTS. General Warnings Installation Programming System Start-Up Frequently Asked Questions... Service Manual Table of Contents TABLE OF CONTENTS Page General Warnings... 3 Installation... 5 Programming... 7 System Start-Up... 8 Frequently Asked Questions... 10 Drawings and Part Numbers... 11 Front

More information

SERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12" DUAL BEVEL COMPOUND MITER SAW B27A

SERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12 DUAL BEVEL COMPOUND MITER SAW B27A PAGE 1 OF 6 BASE ASSEMBLY 00 0 EXAMPLE: Component Parts (Small #) Are Included When Ordering The Assembly (Large #). SPECIFY CATALOG NO. AND NO. WHEN ORDERING PARTS 1 02-80-0050 Thrust Bearing (1) 2 05-80-0510

More information

3200ET Control Valve/Remote Meter Timer

3200ET Control Valve/Remote Meter Timer Service Manual IMPORTANT: Fill in pertinent information on page 3 and page 6 for future reference. Table of Contents Timer Installation And Start-Up Procedures... 3 Timer Start-Up Procedures (Cont d.)...

More information

IF IT FLOWS THE BOWIE PUMP CAN PUMP IT

IF IT FLOWS THE BOWIE PUMP CAN PUMP IT IF IT FLOWS THE BOWIE PUMP CAN PUMP IT Bowie Industries, Inc. Bowie, TX 76230 USA Page 1 Bowie Pumps Manual General Pump Information..Page 2 300 Series Pumps.. Page 5 400 Series Pumps.Page 11 500 Series

More information

Serial Number COSASCO MODEL 60 RETRACTABLE SYSTEM RETRACTOR USER MANUAL

Serial Number COSASCO MODEL 60 RETRACTABLE SYSTEM RETRACTOR USER MANUAL Serial Number COSASCO MODEL 60 RETRACTABLE SYSTEM RETRACTOR USER MANUAL ROHRBACK COSASCO SYSTEMS, INC. 11841 E. Smith Avenue Santa Fe Springs, CA 90670 (562) 949-0123 (800) 635-6898 (562) 949-3065 fax

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

Stainless Steel Single and Dual Circulation Kits

Stainless Steel Single and Dual Circulation Kits Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating

More information

DeZURIK CYLINDER OPERATED G-SERIES ACTUATOR USED ON PFW & PTW TAPERED PLUG VALVES

DeZURIK CYLINDER OPERATED G-SERIES ACTUATOR USED ON PFW & PTW TAPERED PLUG VALVES CYLINDER OPERATED G-SERIES ACTUATOR USED ON PFW & PTW TAPERED PLUG VALVES Instruction D10191 July 2016 Instructions These instructions provide information about G-Series Cylinder Actuators. They are for

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

Aracruz 52AC. Owners Manual and Installation Instructions. Part Number: PL-3238 (Revised ) A Commitment to Excellence

Aracruz 52AC. Owners Manual and Installation Instructions. Part Number: PL-3238 (Revised ) A Commitment to Excellence Aracruz 52AC Owners Manual and Installation Instructions Part Number: PL-3238 (Revised 05.02.07) A Commitment to Excellence READ AND SAVE THESE INSTRUCTIONS Before beginning installation of your new Concord

More information

Model CHASSIS LUBE ELECTRIC GREASE PUMP WITH REMOTE SIGNALING Series "A" - Q3. FEB FORM Section

Model CHASSIS LUBE ELECTRIC GREASE PUMP WITH REMOTE SIGNALING Series A - Q3. FEB FORM Section Model 94823 CHASSIS LUBE ELECTRIC GREASE PUMP WITH REMOTE SIGNALING Series "A" - Q3 FEB - 2009 FORM 403731 Section Page - 27 13.00" (330 mm) 17.72" (450 mm).35" (9 mm) Mounting Holes 4.72" (120 mm) SPECIFICATIONS

More information

Fleck 7000SXT. Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET

Fleck 7000SXT. Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET Fleck 7000SXT Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION...2 START-UP INSTRUCTIONS...2 TIMER FEATURES...3 TIMER OPERATION...4 MASTER PROGRAMMING MODE CHART...5 MASTER PROGRAMMING

More information

PRODUCT MANUAL - M090

PRODUCT MANUAL - M090 PRODUCT MANUAL - M090 MODEL 203/266 ELECTRIC CAN OPENER 1 SAFETY CAUTION: SEVERED CAN LIDS HAVE CUTTING EDGES. USE OF A PROTECTIVE GLOVE OR TONGS IS ADVISED WHEN HANDLING LIDS. WARNING To avoid risk of

More information

TECHNICAL INFORMATION Models No. Description

TECHNICAL INFORMATION Models No. Description TECHNICAL INFORMATION Models No. Description HP2070, HP2070F, HP2071, HP2071F 20mm (3/4") 2-Speed Hammer Drill CONCEPT AND MAIN APPLICATIONS L W NEW TOOL P 1 /13 W L These hammer drills have been developed

More information

WS-40 WS-80 - NOTICE -

WS-40 WS-80 - NOTICE - SERVICE MANUAL WS-40/80 Hobart Compact Water Softener Installation Instructions WS-40 WS-80 - NOTICE - This Manual is prepared for the use of trained Hobart Service Technicians and should not be used by

More information

Industrial Regulator Series 1800/2000 Instructions and Parts List

Industrial Regulator Series 1800/2000 Instructions and Parts List IMP 8740.3 Industrial Regulator Series 1800/2000 Instructions and Parts List AMC Quality System QMI is Accredited by: ISO 9002 Certified Dutch Council for Accreditation Instructions: Industrial Regulator

More information

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS with the 263/742 Logix Control Valve June 2010 Table of Contents Page No.

More information

SIMRAD SD10 Sailboat Drive

SIMRAD SD10 Sailboat Drive INSTALLATION MANUAL SIMRAD SD10 Sailboat Drive 20222683/A English Simrad SD10 Sailboat Drive About this document Rev. A First issue 2007 Navico AS. All rights reserved. No part of this work covered by

More information

! WARNING. Before using product, read and understand instructions.

! WARNING. Before using product, read and understand instructions. McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes

More information

TS93 EMR T/PT/TDE. Surface applied door closer

TS93 EMR T/PT/TDE. Surface applied door closer TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double

More information

OPERATION AND PARTS MANUAL MODEL MQ-D2H/D3H. DIAPHRAGM PUMPS (Honda Gasoline Engine) Revision #2 (05/10/07)

OPERATION AND PARTS MANUAL MODEL MQ-D2H/D3H. DIAPHRAGM PUMPS (Honda Gasoline Engine) Revision #2 (05/10/07) OPERATION AND PARTS MANUAL MODEL MQ-D2H/D3H DIAPHRAGM PUMPS (Honda Gasoline Engine) Revision #2 (05/10/07) To find the latest revision of this publication, visit our website at: www.multiquip.com THIS

More information

BOWIE PUMPS OPERATION - MAINTENANCE

BOWIE PUMPS OPERATION - MAINTENANCE BOWIE PUMPS OPERATION - MAINTENANCE PUMPING PRINCIPLE: The meshing owieeof the gears cause a slight depression, with the resulting enmeshing of the gears causing a vacuum drawing the fluid being pumped

More information

Instructions Installing Enclosed Limit Switch Kit

Instructions Installing Enclosed Limit Switch Kit 1004 East Illinois Street Assumption, IL 62510 1-217-226-4421 Instructions Installing Enclosed Limit Switch Kit Read entire instruction guide before attempting installation. A. Ensure that all components

More information

Installation Instructions for DCI Edge Over the Patient Delivery System

Installation Instructions for DCI Edge Over the Patient Delivery System Table of Contents Page Unit Installation Notes 2 Post Wall/Cabinet Mount Installation 3 Delivery System Installation 3 Self Contained Water System Installation 4 Self Contained Water System Schematic 5

More information

TOP AND CABINET PARTS For Model: WTW5200VQ2 (White)

TOP AND CABINET PARTS For Model: WTW5200VQ2 (White) TOP AND CABINET PARTS AUTOMATIC WASHER 11 08 Litho in U.S.A. (drd)(bay) 1 Part No. Rev. A TOP AND CABINET PARTS 1 Literature Parts Installation Instructions W10200331 English/French W10200662 Spanish Feature

More information

ATEX 94/9/EC SIL3 IEC GOST-R TYPE APPROVAL

ATEX 94/9/EC SIL3 IEC GOST-R TYPE APPROVAL ATEX 94/9/EC SIL3 IEC 61508 GOST-R TYPE APPROVAL 95 90 75 Stroke 15 0 4. Universal and anti-blowout drive shaft It permits an easy conversion from parallel to diagonal square and vice versa. It is also

More information

WARNING. Before using this product, read and understand instructions.

WARNING. Before using this product, read and understand instructions. Series WFE Uni-Match Electric Water Feeder Applications: For use on boilers with mechanical (float type) or electronic (probe type) LWCO's. McDonnell & Miller Installation & Maintenance Instructions MM-323

More information

PRECISION FERTILIZER HITCH

PRECISION FERTILIZER HITCH PRECISION FERTILIZER HITCH DRILL MAINTENANCE Proper servicing and adjustment is the key to the long life of any farm implement. With careful and systematic inspection of your grain drill, you can avoid

More information

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family Part of the Kiva Lighting Family Custom Lighting and Fans Since 1992 1312 12th St NW Albuquerque,

More information

6700XTR Downflow. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

6700XTR Downflow. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference 6700XTR Downflow Service Manual IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference Table of Contents Job Specification Sheet... 3 General Residential Installation Check List... 4 Valve

More information

GEARS Transmission Module with (Optional) Pneumatic Gripper Arm and Limit Switch

GEARS Transmission Module with (Optional) Pneumatic Gripper Arm and Limit Switch GEARS Transmission Module with (Optional) Pneumatic Gripper Arm and Limit Switch Illustrated Assembly Manual The GEARS Transmission and Pneumatic Gripper Arm Module can be used as a stand alone educational

More information

Before installation it is important to know what parts you have and what the capabilities of these parts are.

Before installation it is important to know what parts you have and what the capabilities of these parts are. INSTALLATION GUIDE Before installation it is important to know what parts you have and what the capabilities of these parts are. The Recon XZT is the smallest and most powerful gauge of its kind. With

More information

PULL CHAIN SPEED CONTROL REVERSE SWITCH XTR MOTOR

PULL CHAIN SPEED CONTROL REVERSE SWITCH XTR MOTOR PULL CHAIN SPEED CONTROL REVERSE SWITCH The Casablanca 4-Speed series of fans feature a 4-speed, pull chain fan control and a forward/reverse slide switch. XTR MOTOR PRINTED CIRCUIT BOARD LIGHT KIT PULL

More information

CRYOGENIC AND LOW TEMPERATURE SERVICE TRIAD SERIES BALL VALVES INSTALLATION - MAINTENANCE MANUAL

CRYOGENIC AND LOW TEMPERATURE SERVICE TRIAD SERIES BALL VALVES INSTALLATION - MAINTENANCE MANUAL Date: August 2011 / Page 1 of 6 CRYOGENIC AND LOW TEMPERATURE SERVICE TRIAD SERIES BALL VALVES (FP2000/FP3000 and SP2000/SP3000 WITH CRYO OR LOW TEMP EXTENSION) INSTALLATION - MAINTENANCE MANUAL DESIGN

More information

Automatic Washers Refer to Page 3 for Model Numbers

Automatic Washers Refer to Page 3 for Model Numbers Automatic Washers Refer to Page 3 for Model Numbers Parts W194P www.comlaundry.com Part No. 200638R1 April 2007 Table of Contents Title Page Parts Ordering Information... 2 Nameplate Location... 2 Model

More information

Standard Bills of Materials Commonly Ordered Models Only

Standard Bills of Materials Commonly Ordered Models Only Standard Bills of Materials Commonly Ordered Models Only Meters Always check www.lcmeter.com for the most current BOM. This document is for reference only. Always use Bill of Material shipped with meter

More information

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric

More information

GREASE AND OIL ELECTRIC PUMPS ILC MAX

GREASE AND OIL ELECTRIC PUMPS ILC MAX GREASE AND OIL ELECTRIC PUMPS ILC MAX Ver. 1/16 1 HOW TO ORDER 40.2.24AC.FST.G RESERVOIR 2 = 2 Kg transparent 4 = 4 Kg transparent 8 = 8 Kg transparent 5 = 5 Kg metallic TENSION 12DC = 12 V DC 24DC = 24

More information

STATIC WATER LEVEL MEASUREMENT FLOW METER USER MANUAL.

STATIC WATER LEVEL MEASUREMENT FLOW METER USER MANUAL. STATIC WATER LEVEL MEASUREMENT FLOW METER USER MANUAL www.enoscientific.com Eno Scientific 1606 Faucette Mill Rd Hillsborough, NC 27278 USA www.enoscientific.com 919-778-2660 Copyright Notice Copyright

More information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE

More information

RYOBI BENCH GRINDER MODEL NO. BGH827 REPAIR SHEET

RYOBI BENCH GRINDER MODEL NO. BGH827 REPAIR SHEET RYOBI BENCH GRINDER MODEL NO. BGH827 REPAIR SHEET 4 2 44 6 4 4 29 2 2 29 40 46 2 22 2 42 9 29 6 2 4 0 2 29 2 SEE FIGURE D 7 2 2 2 22 2 2 26 2 24 20 4 6 9 8 7 28 27 28 Figure A 48 27 47 2 SEE FIGURE C 0

More information

POWERS Controls. Technical Instructions Document No P25 AP March 5, No. 6 Pneumatic Damper Actuator.

POWERS Controls. Technical Instructions Document No P25 AP March 5, No. 6 Pneumatic Damper Actuator. POWERS Controls No. 6 Pneumatic Damper Actuator Technical Instructions AP 331-3 Description 331-2793 Actuator 331-2857 Actuator 331-3012 Extended Shaft and Frame with Clevis and Pin Mounting The POWERS

More information

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing) CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.

More information

MASTER. Installation and Operation Manual. Water Conditioning Corp. MCA Time Clock Series Residential Softeners. February 2011 Version

MASTER. Installation and Operation Manual. Water Conditioning Corp. MCA Time Clock Series Residential Softeners. February 2011 Version MASTER Water Conditioning Corp. Installation and Operation Manual MCA Time Clock Series Residential Softeners February 2011 Version Table of Contents Page No. Topic Description 1 Model # and Packaging

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

Blue - Sold as part of Assembly Kit 200 Maroon - Sold as part of Assembly Kit TT. Updated 10/ of 10

Blue - Sold as part of Assembly Kit 200 Maroon - Sold as part of Assembly Kit TT. Updated 10/ of 10 051089 Blue - Sold as part of Assembly Kit 200 Maroon - Sold as part of Assembly Kit 340 05TT O Updated 10/2012 1 of 10 051105 359005 Red - Sold as part of Assembly kit 215. Violet - Sold as part of 054116F,

More information

Basic, Slim & Slim Square Water heater

Basic, Slim & Slim Square Water heater Basic, Slim & Slim Square Water heater Installation and Operating Instructions IT-61019 S Agata Feltria (PU) Italy Phone 390541848030 Fax 390541848563 info@indelmarine.com www.isotherm.com Indel Marine

More information

* * AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

* * AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS 16 1 AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Section Contents 1. Installing a mounting bracket and light

More information

Section M POWER LIFTS

Section M POWER LIFTS Section M POWER LIFTS January 2003 1M Index 1. 53-520244-000 Poly V Idler Assembly 2. 53-520205-000 Mounting Bracket 3. 53-520212-000 Cable Assembly 4. 53-600149-000 Wire Harness Assembly 5. 53-860322-010

More information

DeZURIK CYLINDER OPERATED G-SERIES ACTUATOR USED ON PEC ECCENTRIC VALVES

DeZURIK CYLINDER OPERATED G-SERIES ACTUATOR USED ON PEC ECCENTRIC VALVES CYLINDER OPERATED G-SERIES ACTUATOR USED ON PEC ECCENTRIC VALVES Instruction D10022 August 2012 Instructions These instructions provide information about G-Series Cylinder Actuators. They are for use by

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Application Outboards Faria 5 Gauge Set* Publication No. Description Part Number Honda Code PII53606A White faced, flat lens 06300-ZW5-010ZB 6315410 Issue Date Black faced, flat

More information

Owner s Manual. 5600 / 5600 Econominder

Owner s Manual. 5600 / 5600 Econominder 5600 / 5600 Econominder Owner s Manual For questions or in case of emergency, please call your local service technician (preferably the one who installed the system). Product Features, Benefits, & Job

More information

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions 4057250/8 IM-P405-16 AB Issue 8 ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions 1 General safety information 2 General product information 3 Installation 4 Operation

More information

POWERS Controls No. 4 Pneumatic Damper Actuator

POWERS Controls No. 4 Pneumatic Damper Actuator POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000

More information

SunMaxx Solar Filling Station Operating Instructions

SunMaxx Solar Filling Station Operating Instructions SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...

More information

13CD609G HP Lawn Tractor (2002) Page 1 of Inch Deck

13CD609G HP Lawn Tractor (2002) Page 1 of Inch Deck 13CD609G063 17.5HP Lawn Tractor (2002) Page 1 of 20 42 Inch Deck 13CD609G063 17.5HP Lawn Tractor (2002) Page 2 of 20 42 Inch Deck 1 16606 1 S Bracket: Retainer Hook 2 618-0565 1 S Spindle Assembly: Pulley

More information

LOBEE VERTICAL SUMP PUMP LOBEE MODEL S/SH AND SA/SHA SUMP PUMPS INSTALLATION AND OPERATING INSTRUCTIONS

LOBEE VERTICAL SUMP PUMP LOBEE MODEL S/SH AND SA/SHA SUMP PUMPS INSTALLATION AND OPERATING INSTRUCTIONS SPT3/2010 LOBEE VERTICAL SUMP PUMP LOBEE MODEL S/SH AND SA/SHA SUMP PUMPS INSTALLATION AND OPERATING INSTRUCTIONS These instructions are important - please read them thoroughly before installing your Lobee

More information

MOROSO P/N ROTOR AND SCROLL EXTERNAL OIL PUMP SINGLE STAGE WITH PASSENGER SIDE MOUNTING PROVISION

MOROSO P/N ROTOR AND SCROLL EXTERNAL OIL PUMP SINGLE STAGE WITH PASSENGER SIDE MOUNTING PROVISION MOROSO P/N 22596 -ROTOR AND SCROLL EXTERNAL OIL PUMP SINGLE STAGE WITH PASSENGER SIDE MOUNTING PROVISION Before installing your pump, be sure you have the proper Moroso components to go with it. Using

More information

Blue - Sold as part of Assembly Kit 200 Maroon - Sold as part of Assembly Kit TT. Updated 10/ of 10

Blue - Sold as part of Assembly Kit 200 Maroon - Sold as part of Assembly Kit TT. Updated 10/ of 10 Blue - Sold as part of Assembly Kit 200 Maroon - Sold as part of Assembly Kit 340 04TT Updated 10/2011 1 of 10 Red - Sold as part of Assembly kit 215. Violet - Sold as part of 054116F, NOT sold separately.

More information

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This

More information

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer Overview READ ENTIRE INSTRUCTIONS BEFORE STARTING INSTALLATION PARTS LIST A. Flush valve B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve

More information

Number Wheeler P/N Description Set Rex P/N Notes 1 603500 Base 1 J001 2 603501 Support, Right 1 J002 3 603502 Support, Left 1 J003 4 600328 Nut (M8)

Number Wheeler P/N Description Set Rex P/N Notes 1 603500 Base 1 J001 2 603501 Support, Right 1 J002 3 603502 Support, Left 1 J003 4 600328 Nut (M8) 1 603500 Base 1 J001 2 603501 Support, Right 1 J002 3 603502 Support, Left 1 J003 4 600328 Nut (M8) 4 5 600130 Spring Washer (8mm) 4 6 600344 Roll Pin (M6x30) 4 7 600129 Socket Hd Cap Screw (M8x25) 4 8

More information

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE 4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement

More information

SUPERPLUS WATER FILTRATION SYSTEM

SUPERPLUS WATER FILTRATION SYSTEM SUPERPLUS WATER FILTRATION SYSTEM For Model #: SP20-2, SP40-2 INSTRUCTIONS/ASSEMBLY USE AND CARE MANUAL (Important: Read this manual thoroughly before install) TABLE OF CONTENTS 2 3 4 6 8 9 10 11 12 General

More information

MASTER. Water Conditioning Corp. MP-MBA-15T-30T using the 255/762 Logix Control Valve. Installation and Operation Manual. www.masterwater.

MASTER. Water Conditioning Corp. MP-MBA-15T-30T using the 255/762 Logix Control Valve. Installation and Operation Manual. www.masterwater. MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MP-MBA-15T-30T using the 255/762 Logix Control Valve July 2006 Table of Contents Page No. Topic Description 1 Model

More information

VOYAGER 570G. 744A Sprayer Control

VOYAGER 570G. 744A Sprayer Control VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER

More information

ATS Overhead Table Shelf System INSTRUCTION MANUAL

ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship

More information

Section M POWER LIFTS

Section M POWER LIFTS Section M POWER LIFTS December 2009 1M Index 1. 53-520244-000 Poly V Idler Assembly 2. 53-520205-000 N.A. Mounting Bracket 3. 53-520212-000 Cable Assembly 4. 53-600149-000 Wire Harness Assembly 5. 53-860322-010

More information

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS Section: MOYNO 500 PUMPS Page: 1 of 8 Date: March 1, 1998 SERVICE MANUAL MOYNO 500 PUMPS 300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS Mechanical Seal Models Packing Gland Models MODELS DESIGN FEATURES

More information

MUELLER A-20806/A ADJUSTABLE VERTICAL INDICATOR POST

MUELLER A-20806/A ADJUSTABLE VERTICAL INDICATOR POST INSTALLATION INSTRUCTIONS MUELLER A-20806/A-20807 STARTING YEAR DATE 2011 GENERAL DESCRIPTION Vertical Indicator Posts (Ref. Figure A) are designed to operate non-rising stem (inside screw) gate valves,

More information

Submersion/Insertion Toroidal Sensor

Submersion/Insertion Toroidal Sensor Instruction Sheet PN 51A-228/rev.P December 2010 Model 228 Submersion/Insertion Toroidal Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION SENSOR/PROCESS

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic

More information

Installation Instructions FOR HARLEY-DAVIDSON 5 Speed Transmissions EVO / 5 Speed & Twin Cam

Installation Instructions FOR HARLEY-DAVIDSON 5 Speed Transmissions EVO / 5 Speed & Twin Cam Installation Instructions FOR HARLEY-DAVIDSON 5 Speed Transmissions 84 99 EVO / 5 Speed & 99 06 Twin Cam Illustrated Parts List * Main Shaft Gear (Small gear) (1) Special Tool (1 set): 3/4" Socket Adapter

More information

UFO 1 FOLDER INDEX A2 FOLDING MACHINE TYPE 10060 LIST NO DESCRIPTION PAGE 10101M Main Assembly - Mechanical 2 10201M Main Roller Assembly 4 16101M Upper & Lower Perforator Shaft Assembly 6 12701M Primary

More information

Bliz Whiz. Ice Shaver Instruction Manual Model #1001. Cincinnati, OH 45241-4807 USA. Part No. 12069 Revised June 1996

Bliz Whiz. Ice Shaver Instruction Manual Model #1001. Cincinnati, OH 45241-4807 USA. Part No. 12069 Revised June 1996 Ice Shaver Instruction Manual Model #1001 Part No. 12069 Revised June 1996 Cincinnati, OH 45241-4807 USA SAFETY PRECAUTIONS This equipment is designed and sold for commercial use only. This equipment is

More information

Mig C280 PRO, Mig C340 PRO. Spare parts list. Edition Valid for serial no. 627-xxx-xxxx, 119-xxx-xxxx,

Mig C280 PRO, Mig C340 PRO. Spare parts list. Edition Valid for serial no. 627-xxx-xxxx, 119-xxx-xxxx, Spare parts list Edition 20120710 Valid for serial no. 627-xxx-xxxx, 119-xxx-xxxx, Ordering no. Product 0349 302 889 Origo Mig C280 PRO 400-415 V, 3~50 Hz 0349 302 844 Origo Mig C280 PRO 230/400-415/415/500V,

More information

STABITHERM INSTALLATION & SERVICE BOOKLET

STABITHERM INSTALLATION & SERVICE BOOKLET STABITHERM INSTALLATION & SERVICE BOOKLET TABLE OF CONTENTS Introduction...3 Warranty...3 Product Range and Physical Description...4 Method of Operation...5 Recommended Pressures and Temperatures...6 Flow

More information

Clear Filter Press Instructions

Clear Filter Press Instructions Clear Filter Press Instructions Leader Evaporator Co., Inc. 49 Jonergin Drive Swanton, VT 05488 Tel: 802-868-5444 www.leaderevaporator.com Contents INTRODUCTION... 3 EQUIPMENT DESCRIPTION... 3 Optional

More information

MAXICUT FLEX WING MOWERS

MAXICUT FLEX WING MOWERS MAXICUT 600 FLEX WING MOWERS PARTS MANUAL 5301-04 - 12 Twose of Tiverton Limited 6 Chinon Court, Lower Moor Way, Tiverton Business Park, Tiverton, Devon. EX16 6SS. Telephone: (01884) 253691 Fax: (01884)

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series Series VQ0 VCH VDW VQ

More information

HARBIL. NSC50 Compact Colorant Dispenser. Operating and Instruction Manual. Part # Rev. E 06/07/01

HARBIL. NSC50 Compact Colorant Dispenser. Operating and Instruction Manual. Part # Rev. E 06/07/01 HARBIL NSC50 Compact Colorant Dispenser Operating and Instruction Manual Part # - 4700220 Rev. E 06/07/01 CONFIDENTIAL PROPERTY OF FLUID MANAGEMENT (C) COPYRIGHT 2001 FLUID MANAGEMENT AS AN UNPUBLISHED

More information