MT 28 / MA 28 / ET 28 / PT 28

Size: px
Start display at page:

Download "MT 28 / MA 28 / ET 28 / PT 28"

Transcription

1 T A PT ET

2 PRESSONS T / A / ET / PT Small in format, but great in its potentials: The buttons and indicators from Style along with many matching components, make the scope of design almost unlimited. Whether it is an arranged car fixture, or a space-saving landing fixture with a minimalist design the choice of elements and materials determine the look. While the Armour Button type PT is especially durable, the Electronic Button type ET also serves as a basic element for large-format variants, which range in various shapes and material combinations. Car fixture st. steel, brushed Car fixture st. steel, brushed (water-protected) Car fixture st. steel, brushed COP-Panel st. steel surface design Austenit COP-Panel st. steel engravings, white Car fixture st. steel, brushed Landing fixtures st. steel, brushed J 1.2

3 NSPRATONS T / A / ET / PT Touch plates and caps Choice of faceplate materials JJJ JJJ TiN-coating matt TiN-coating Hairline TiN-coating polished st. steel, black st. steel, matt PT touch plate st. steel, matt Car fixture in nostalgic look browned Car fixture TiN-coating, polished LP cap red LP cap green LP A LP cap opal LR LR LR TiN-coating matt TiN-coating Hairline TiN-coating polished LR st. steel, black Car fixture TiN-coating rounded shape LR st. steel, matt RLR RLR RLR RLR st. steel, black RLR st. steel, matt RP RP TiN-coating matt TiN-coating Hairline TiN-coating polished polycarbonate yellow T RP cap polycarbonate crystal clear LR st. steel, matt P P P st. steel, blank st. steel, blank polycarbonate crystal clear polycarbonate red polycarbonate yellow T cap st. steel, blank Further touch plate/cap finishes available on demand J 1.3

4 CAPS T / A Typ TS1 pierced crystal clear cap st. steel, blank square, mm x mm pierced crystal clear (injected) yellow foil for alarm symbol height of characters 8 mm (min. 4 mm) height of symbols mm (min. 4 mm) connection technology base TS1 recall light character illumination LED bulb BA 7s U = 30 V AC/DC option U = V AC/DC = 20 ma pierced crystal clear cap st. steel, blank square, mm x mm pierced crystal clear (injected) yellow foil for alarm symbol height of characters 8 mm (min. 4 mm) height of symbols mm (min. 4 mm) connection technology base TS1 recall light bulb BA 7s U = 6,,, 30 V AC/DC option U = 36, 48, 60 V AC/DC P = 1.2 W LR RLR cap with touch plate st. steel, matt square, mm x mm, or round, ø mm engraving (black, option: colour, RAL shades) or laser-marked polycarbonate halo, opal (white translucent) option: halo coloured differently LR RLR engraving laser height of characters 8 mm height of symbols mm connection technology base TS1 recall light bulb BA 7s Various JY JY U = 6,,, 30 V AC/DC option U = 36, 48, 60 V AC/DC P = 1.2 W 1.4

5 CAPS T / A Typ TS1 cap polycarbonate, crystal clear or yellow square, mm x mm, or round, ø mm film / foil / insert P RP film positive/negative height of characters 8 mm height of symbols mm connection technology base TS1 recall light bulb BA 7s P RP U = 6,,, 30 V AC/DC option U = 36, 48, 60 V AC/DC P = 1.2 W LP cap polycarbonate, opal (white translucent), red or green (further colours available on demand) arrow-shaped, mm x mm ounting possible in any direction connection technology base TS1 recall light bulb BA 7s ORDER DATA LP U = 6,,, 30 V AC/DC option U = 36, 48, 60 V AC/DC P = 1.2 W LP 1.5

6 CAPS T / A Typ, V, X TS1 3 4 cap st. steel, blank square, mm x mm engraving (black, option: colour, RAL shades) or laser-marked height of characters 8 mm height of symbols mm Various JY JY engraving laser recall light LED U = 30 V AC/DC option U = V AC/DC = 20 ma P film positive/negative cap polycarbonate, crystal clear or yellow square, mm x mm film / foil / insert height of characters 8 mm height of symbols mm recall light LED U = 30 V AC/DC option U = V AC/DC = 20 ma When combined with T, illumination of entire surface possible. J J recall light surface illumination LED bulb BA 7s U = 6,,, 30 V AC/DC option U = 36, 48, 60 V AC/DC P = 1.2 W 1.6

7 TOUCH PLATES PT / ET Typ touch plate PT, TS1 touch plate st. steel, matt square, mm x mm engraving (black, option: colour, RAL shades) or laser-marked height of characters 8 mm height of symbols mm touch plate PT, engraving Touch plates for the PT are not available as spare parts. touch plate ET, Various JY JY engraving laser connection technology base TS1 o recall light LED U = 30 V AC/DC option U = V AC/DC = 20 ma touch plate st. steel, ground (grain 180) square, 20 mm x 20 mm engraving (black, option: colour, RAL shades) or laser-marked connection technology base TS1 recall light bulb BA 7s ORDER DATA T / A touch plate ET, engraving Various JY JY engraving laser U = 6,,, 30 V AC/DC option U = 36, 48, 60 V AC/DC P = 1.2 W ET PT 1.7

8 T / A icro Button / icro ndicator T Recall light T /A J J A Daten Characteristics Fixing welding studs 3 x 10 (faceplate fixing) base plate (back box fixing) Faceplate thickness 2 mm... 3 mm Connection TS1 0.1 mm² mm² technology pre-wiring option with series mounting Switching snap switch, 1 alternating contact element T (option: second alternating contact) LED switching voltage = 30 V DC switching current = 0.8 A ohmic load switching current = 0.5 A inductive load L/R = 3 ms switching voltage = 30 V AC switching current = 1 A bulb switching voltage = 0 V DC switching current = 0.5 A ohmic load switching current = 0.2 A inductive load L/R = 3 ms switching voltage = 250 V AC switching current = 1 A Stroke T 2 mm Dimensions R P A TS C T HE R (3) Faceplate fixing /ø (3) Back box fixing /ø Please order fixing accessories separately. * valid for second contact Schaltbild Wiring diagram space for cables Durchbruch Cutout 36 ±0.1 welding stud 3 x 10 Aluminium profile box Base plate fixing JJJ / JJJ T T / A C NC *() *() *() + _ R ø engraving laser pierced, crystal clear film

9 T / A T / A Pre-wiring VVV1 T mit with LED, gemeinsame common cathode Kathode Schaltbild Wiring diagram Top Sockel view Draufsicht base base type TS1 o T C L() + _ BR C(+) L(-) A L() T mit with LED, gemeinsame common anode Anode base type TS1 o Wiring Schaltbild diagram T C L() Top Sockel view Draufsicht base _ + ORDER DATA BR L(+) C(-) A L() T mit with Glühlampe, bulb, common gem. anode/cathode Anode / Kathode base type TS1 Schaltbild Wiring diagram Top Sockel view Draufsicht base C BR A L 2 L C(+/-) L(-/+) Wiring VVV 1 Standard configuration WJ / WJ

10 A LP icro ndicator Luminous Arrow Daten Characteristics Fixing Faceplate thickness Connection technology Recall light welding studs 3 x 10 (faceplate fixing) base plate (back box fixing) 2 mm... 3 mm 0.1 mm² mm² TS1 pre-wiring option with series mounting bulb BA 7s U = 6,,, 30 V AC/DC option U = 36, 48, 60 V AC/DC P = 1.2 W Recall light A LP J Abmessungen Dimensions R P A TS CT HE R (3) Faceplate fixing (3) Back box fixing Please order fixing accessories separately. space for cables Aluminium profile box Base plate fixing JJJ / JJJ Schaltbild Wiring diagram Durchbruch Cutout R ±0.1 welding stud 3 x

11 T / A OUNTNG A LP A LP A LP turned by A LP A LP turned by 180 ORDER DATA A LP turned by A LP turned by 90 A LP turned by A LP turned by 90 1.

12 T V icro Button V Daten Characteristics Fixing welding studs 3 x 10 Faceplate thickness 2 mm... 3 mm Connection AWG 26-3 technology option: AWG 26-2 second -contact Switching element snap switch, 1 -contact (option: second -contact) Recall light T J switching voltage = 30 V DC switching current = 0.8 A ohmic load switching current = 0.5 A inductive load L/R = 3 ms switching voltage = 30 V AC switching current = 1 A Recall light LED Stroke U = 30 V AC/DC option U = V AC/DC = 20 ma 2 mm Please order fixing accessories separately Rückansicht Rear view Abmessungen Dimensions 2 (3) R P A TS CT HE R welding stud 3 x 10 Schaltbild Wiring diagram Durchbruch Cutout 36 ± cathode anode optional C L C L C2 2 R engraving/laser film

13 T / A T X icro Button X Daten Characteristics Fixing welding studs 3 x 10 Faceplate thickness 2 mm... 3 mm Connection AWG 26 - technology option: AWG 26-2 second -contact 4 Switching element Ssnap switch, 1 -contact (option: second -contact) Recall light T J Recall light switching voltage = 30 V DC switching current = 0.8 A ohmic load switching current = 0.5 A inductive load L/R = 3 ms switching voltage = 30 V DC switching current = 1 A LED ORDER DATA Stroke U = 30 V AC/DC option U = V AC/DC = 20 ma 2 mm Please order fixing accessories separately. Rückansicht Rear view Abmessungen Dimensions 2 (3) PR A TS CT HE R welding stud 3 x 10 Schaltbild Wiring diagram Durchbruch Cutout 36 ± optional C1 1 _ + C2 2 R engraving/laser film 1.

14 FRAE Style, square Daten Characteristics Frame Fixing Function st. steel matt, 6 mm high 2 x countersunk screw 3 x 5 (included) protection against unintended operation Abmessungen Dimensions R P A TS CT HE R 75 R2.8 R ± ± Durchbruch Cutout ø 3.5 /90 countersunk for 3 x Drilling template available on demand

15 Frame ORDER DATA 1.15

16 PT Armour Button This button is not suitable for use as an alarm/door open button. The reason being: by operation of the button the signal is only set for about 1 second. As a respective alternative for an alarm/door open button we recommend: T, design PT. Daten Characteristics Fixing welding studs 3 x 10 (faceplate fixing) base plate (back box fixing) Faceplate thickness 2 mm 3 mm Connection TS1 0.1 mm² mm² pre-wiring option with series mounting Functional principle piezo-electric Supply voltage U = V V DC Switching element relay, 1 alternating contact (potential-free) switching voltage = 0 V AC switching current = 1 A switching capacity = 30 W switching voltage = 30 V DC switching current = 41 A switching capacity = 30 VA Recall light LED Compliance Abmessungen Abmessungen Dimensions U = = option EN R P A TS CT HE R 75 V V AC/DC 20 ma CLASS 1 welding stud 3 x (3) Faceplate fixing 40 2 (3) Back box fixing Please order fixing accessories separately. space for cables Aluminium profile box Base plate fixing JJJ / JJJ NC C + _ + R ±0.1 welding stud 3 x 10 Wiring diagram Cutout _ 1.16 engraving/laser

17 PT PT Pre-wiring VVV1 PT mit with LED, gemeinsame common cathode Kathode Schaltbild Wiring diagram Top Sockel view Draufsicht base base type TS1 o C BR L() C(+) L(-) (+) PT mit with LED, gemeinsame common anode Anode Schaltbild Wiring diagram Top Sockel view Draufsicht base base type TS1 o C BR L() L(+) C(-) _ + _ + (-) (+) ORDER DATA Wiring VVV 1 Standard configuration WJ / WJ

18 ET Electronic Button Daten Characteristics Fixing welding studs 3 x 10 (faceplate fixing) base plate (back box fixing) Faceplate thickness 2 mm... 3 mm Connection TS1 0.1 mm² mm² technology pre-wiring option with series mounting Supply voltage U = V DC ±5 % Switching element relay, 1 alternating contact (potential-free) switching voltage = 0 V AC switching current = 1 A switching capacity = 33 W Being a capacitive button, the ET will not generate a signal when operated for example: while wearing a thick leather glove. Recall light switching voltage = 50 V DC switching current = 1 A switching capacity = 33 VA bulb BA 7s The ET also serves as basic element for large-format capacitive buttons in a range of various shapes and material combinations. As alarm respectively door open button we recommend: T LR U = 6,,, 30 V AC/DC option U = 36, 48, 60 V AC/DC P = 1.2 W Abmessungen Dimensions R P A TS CT HE R 75 2 (3) 45 Faceplate fixing (3) Back box fixing Please order fixing accessories separately. 58 ±0.1 welding stud 3 x 10 Aluminium profile box Base plate fixing Schaltbild Wiring diagram Durchbruch Cutout JJJ / JJJ NC + C R _ 1.18 engraving/laser

19 ET ET Pre-wiring VVV1 ET mit with Lampe, bulb, common gemeinsame cathode Kathode Schaltbild Wiring diagram Top Sockel view Draufsicht base base type TS1 C (-) + + _ BR C(+) (-) (-) (+) ET mit with Lampe, bulb, common gemeinsame anode Anode Schaltbild Wiring diagram Top Sockel view Draufsicht base base type TS1 C (+) _ + _ BR C(-) (-) (+) (+) Wiring VVV 1 Standard configuration WJ / WJ ORDER DATA

20 1.20

21 ARKNG engraving laser Various JY JY Font: Swiss 7 dbt 8 The heights of markings for characters and symbols are identical with all buttons and indicators from the Style. pierced crystal clear The heights of markings for characters and symbols are identical with all buttons and indicators from the Style. number of characters =^ height of characters Due to the production process the appearance of the shown characters/symbols may vary from the original depending on the touch plate/cap variant. film positive/negative 1.

22 Film engraving laser LR RLR ET ARKNG STYLE PT film P RP STYLE T A TYPE TOUCH PLATE/CAP st. steel, blank st. steel, blank RECALL LGHT pierced crystal clear TS1 T A LR RLR st. steel, matt polycarbonate halo, opal Floors: Floors: P RP polycarbonate crystal clear, yellow P polycarbonate crystal clear, yellow LP polycarbonate opal, red, green Symbols according to DN 15325: Symbols according to DN 15325: T V st. steel, blank pages J J T X P polycarbonate crystal clear, yellow Further available symbols: Further available symbols: PT TS1 PT st. steel, matt pages J J ET TS1 ET st. steel, ground (grain 180) pages J J Updated list available on demand For PCTOGRA survey see prefix

23 81-71 LED/BULB (U in V) bulb BA 7s 6,,, 30 AC/DC option: 36, 48, 60 AC/DC 30 AC/DC option: AC/DC LED/LAPE FARBE ARKNG ORENTATON R FRAE pierced crystal clear pierced crystal clear J. 1. engraving/ laser J. 1. bulb BA 7s 6,,, 30 AC/DC option: 36, 48, 60 AC/DC engraving/ laser J. 1. bulb BA 7s 6,,, 30 AC/DC option: 36, 48, 60 AC/DC 30 AC/DC option: AC/DC film positive/ negative film positive/ negative J. 1. J. 1. bulb BA 7s 6,,, 30 AC/DC option: 36, 48, 60 AC/DC turned by 90 turned by 180 turned by AC/DC option: AC/DC 30 AC/DC option: AC/DC 30 AC/DC option: AC/DC engraving/ laser film positive/ negative ORDER EXAPLE T V, cap, st. steel, blank, LED 30 V, yellow,, orientation 0 option EN CLASS 1 J. 1. J. 1. engraving/ laser ORDER EXAPLE PT, touch plate st. steel, matt, LED 30 V, yellow,, orientation 0 bulb BA 7s 6,,, 30 AC/DC option: 36, 48, 60 AC/DC engraving/ laser

Further materials as well as handling of externally supplied materials on demand III

Further materials as well as handling of externally supplied materials on demand III Faceplates and mounting options Faceplate Materials The first impression is important even with fixtures. The choices of faceplate materials play an essential role. Ground stainless steel, gold-coloured

More information

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color) Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum

More information

Q SERIES Ø14mm (.551") Panel Mount LED Indicators Distinctive features and specification

Q SERIES Ø14mm (.551) Panel Mount LED Indicators Distinctive features and specification Distinctive features and specification Q14_VOY1609R2US Features 14mm panel mounting LED indicator 10mm colored diffused epoxy lens or 10mm water clear super bright LEDs Plated brass bezel finished in bright

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...

More information

COMPALARM AP GENERAL MAIN FEATURES

COMPALARM AP GENERAL MAIN FEATURES GENERAL The COMPALARM AP is a point alarm system, with as many normally closed input contacts. It givesthe possibility of selecting the alarm sequence according with 0 x 0 mm cells, fitted with ultra bright

More information

HARTING Ethernet Cabling 8-poles Overview

HARTING Ethernet Cabling 8-poles Overview Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs

More information

POINTS POSITION INDICATOR PPI4

POINTS POSITION INDICATOR PPI4 POINTS POSITION INDICATOR PPI4 Advanced PPI with Adjustable Brightness & Simplified Wiring Monitors the brief positive operating voltage across points motors when they are switched Lights a corresponding

More information

Contrast 2 LED. Performance Compactness Complete flexibility NEW

Contrast 2 LED. Performance Compactness Complete flexibility NEW NEW Contrast 2 LED High light output in a compact and discreet design with a wide choice of light effects created using different light distributions and accessories Performance Compactness Complete flexibility

More information

HCR3.2/.. Chipcard reader HOTEL SOLUTION

HCR3.2/.. Chipcard reader HOTEL SOLUTION s 6 332 HOTEL SOLUTION Chipcard reader HCR3.2/.. Chipcard reader for hotel room access control Reads access code on chipcard Transfers access code to room controller Built-in optical display of messages

More information

LED - Indicator Panels

LED - Indicator Panels energy management systems 09 LED - Indicator Panels Standard LED - Indicator Panels LM...72, LM...96, LM...144 page 9/1 Indicator panels with 3 color LEDs SM...96 page 9/9 LED - INDICATOR PANELS LED-Indicator

More information

Wiring diagrams for luminous 1P 1-way switches with 110 V~ or 250 V~ signalling units

Wiring diagrams for luminous 1P 1-way switches with 110 V~ or 250 V~ signalling units Devices Switches - TECHICA CHARACTERISTICS Scope Switching on and off of ohm-inductive loads: lighting circuits: - lighting fittings (luminaires) for use incandescent lamps - lighting fittings (luminaires)

More information

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design .8 Ex-Recess-mounted, ceiling emergency light fittings in compact metal design RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX 50... N 18-36 W (Zone 1,, 1, ) The explosion-protected lighting concept for clean rooms

More information

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T Universal industry standard encoder Up to 40 000 steps with 0 000 pulses High signal accuracy Protection class up to IP67 Flexible due to many flange and configuration variants Suitable for high shock

More information

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions Disabled Toilet Alarm Installation & Operating Contractor Pack Installation & Operating Instructions 1 Overview The Channel Safety Systems Disabled Toilet alarm contractor Packs are an efficient way of

More information

mecotron Safety relay ESTOP-2 For emergency stop monitoring

mecotron Safety relay ESTOP-2 For emergency stop monitoring E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated

More information

Switches & Pilot Devices

Switches & Pilot Devices Key features: 21/4 (8mm) round mounting hole Compact Design Saves Space Bright and Vivid Illumination Choice of Shapes and Functions old Clad Silver Contacts for reliable low level switching Snap action

More information

SMS 4 / SMS 5 safety mat Product information

SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,

More information

Switches SWITCHES SWITCHES

Switches SWITCHES SWITCHES Switches Manufactured from Stainless Steel, Bulgin s extensive range of vandal resistant security switches are designed with a high resistance to wear and tear, corrosion and harsh use in potentially hostile

More information

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently (68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please

More information

instabus KNX / EIB System System E F G H

instabus KNX / EIB System System E F G H Product name: Uninterruptible power supply (USV) 640 ma Design: REG (rail-mounted device) Article-no.: 1079 00 ETS search path: Gira Giersiepen / system components / power supply / power supply 640mA DRA

More information

TS93 EMR T/PT/TDE. Surface applied door closer

TS93 EMR T/PT/TDE. Surface applied door closer TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double

More information

Proximity Switches RS (Reed Switch)

Proximity Switches RS (Reed Switch) Proximity Switches RS (Reed Switch) General Pneumatic systems can often be combined with electric control circuits. The position of the piston in the cylinder can then be sensed by means of a proximity

More information

Vario-Series Accessories

Vario-Series Accessories Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

Switches and Indicators. Swisstac

Switches and Indicators. Swisstac Switches and Indicators Switches and Indicators Index Series Description Page 583 Product Assembly Page 584 Mounting Instruction Page 585 Product Range - pushbuttons for standard mounting - pushbuttons

More information

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders

More information

BANDE. switch panel with flat push-button. cjcsystems com

BANDE. switch panel with flat push-button. cjcsystems com BANDE switch panel with flat push-button cjcsystems com 48 switch panels 230v CJC5581A 1 push-button CJC5582A 2 push-buttons CJC5584A 4 push-buttons 118 x 85 x 6 In built-in boxes type TICINO503e wiring

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

KONE EN81-71 CAtegory 1. Vandal Resistant Lift

KONE EN81-71 CAtegory 1. Vandal Resistant Lift KONE EN81-71 CAtegory 1 Vandal Resistant Lift Car Finishing Options: MonoSpace Standard Ceilings LF94 Doors Asturias Satin (F) Walls Stainless steel Asturias Satin (F) Flemish Linen (M) Scottish Quad (K)

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features gang engertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

www.sebury.com.cn Digital Keypad Use s Manual

www.sebury.com.cn Digital Keypad Use s Manual K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4

More information

3 740 Wrist strap + shoe tester

3 740 Wrist strap + shoe tester 3 740 Wrist strap + shoe tester Operating Instructions April, 2001 740 wrist strap + shoe tester 3 < o.k. > 1 2 1 / 11 LED for «too w resistance» 740 wrist strap + shoe tester 3 < o.k. > 1 2 LED for «too

More information

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable Port side cable (with black cable tie attached) Power cable Preparing for Installation 1 Overall

More information

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Lighting Packages. 230 VAC Fluorescent Enclosure Light: Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for

More information

Signal Tower modulsignal50

Signal Tower modulsignal50 Signal Tower modulsignal50 S I G N A L G E R Ä T E modulary construction with bayonet locking system fast and easy to operate, mount, configurate and change of modules troublefree and fingersafe bulb change

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau KA 180F/00/en/06.01 (a) 52010984 Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau Safety instructions The FTS 20 floating switch may only be used as a level limit switch

More information

Industrial Linergy LED

Industrial Linergy LED Eaton s commitment to supplying energy saving innovative products is the driving force behind. follows in the tradition of highly efficient large space luminaires which have the performance and flexibility

More information

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS FRANCE Head office USA 4 Rue du Bois Chêne le loup Parc d Activité de Brabois 54 500 VANDOEUVRE LES NANCY (33) 0383442413, Fax (33) 0383443797

More information

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS Photoelectric These sensors use light sensitive elements to detect objects and are made up of an emitter (light source) and a receiver. Four types of photoelectric

More information

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions Compact presence detector Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause

More information

241 12 V / H7 AND H4 12 V / H1 AND H3 242

241 12 V / H7 AND H4 12 V / H1 AND H3 242 CAR LIGHT BULBS 241 12 V / H7 AND H4 12 V / H1 AND H3 242 H7 H1 4,1 44 max. 4,1 44 max. 25 25 16 max. 16 max. 3720-064-209 12 V H7 Long Life 5 Px26d 3723-064-2 12 V H7 5 Px26d 3720-064-250 12 V H1 Vision

More information

13 SERIES. Electronic step relays 10-16 A 13.81 13.91

13 SERIES. Electronic step relays 10-16 A 13.81 13.91 13 Electronic step relays 10-16 A 13 13.81 - Electronic step relay - Rail mount - 1 Pole 13.91 - Electronic step relay and timing step relay Switch box mount - 1 Pole Fixed time (10 minutes) timing function

More information

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring

More information

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000 Security Alarm Central Unit 3 4 Technical KNX Alarm central unit EAM 4000 ETS-product family: Alarm system Product type: Alarm central unit The alarm central unit is a modern alarm system using the KNX

More information

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050 Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage

More information

N&H Technology GmbH. Silicone Rubber Keypad. Single Source Supply. Design Guide - Short Version. Engineering in Germany - Production in East Asia

N&H Technology GmbH. Silicone Rubber Keypad. Single Source Supply. Design Guide - Short Version. Engineering in Germany - Production in East Asia N&H Technology GmbH Import & Export of Industrial Products Technical Support and Engineering Business Consulting and Representation Silicone Rubber Keypad Design Guide - Short Version Single Source Supply

More information

Mureva Assembly surface mounted wiring devices

Mureva Assembly surface mounted wiring devices 1.0 Waterproof Assembly surface Switches P124543 P124547 External dimensions : 72 x 72 x 47 mm.. Assembly surface rockers become illuminated using bulbs and indicators in option. They can carry a label

More information

Garage Sectional Doors

Garage Sectional Doors Garage Sectional Doors FROM TECKENTRUP TOP CLASS QUALITY DOORS MADE OF STEEL; ALUMINIUM OR WOOD W E O P E N T H E D O O R S F O R P R O G R E S S ECONOMICAL AND SPACE-SAVING FOR EVERY STRUCTURAL SITUATION

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs

More information

S Series Slide Switches

S Series Slide Switches Switches Features/Benefits 6 to 15 AMPS Enclosed housing PC and Snap-in panel mounting Reversing option RoHS compliant Typical Applications Portable tools Small appliances Floor care products Models Available

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual

More information

Contact expansion modules

Contact expansion modules Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Solid-State Timer H3G

Solid-State Timer H3G ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-11000(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : sales@ashalain.com Solid-State Timer Low-Cost, Plug-In

More information

Input module, input/output module

Input module, input/output module Sinteso / Cerberus PRO Input module, input/output module FDCI221, FDCIO221 Input module and input/output module for the automatically addressed detector line Input module FDCI221: Monitorable contact input

More information

Thickness Gauges. convex R 15 or R 40, flat 10 mm Ø, spherical

Thickness Gauges. convex R 15 or R 40, flat 10 mm Ø, spherical Thickness Gauges Technical Data for Metric Thickness Gauges Page Model Lifting Contact points Contact points mm mm mm device standard available on request 130 K 15 0.1 10 15 no 6.35 mm Ø flat Ø flat, 130

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

LED MACHINE ILLUMINATIONS

LED MACHINE ILLUMINATIONS white LED light industrial-suited housing energy-efficient ipf electronic gmbh Kalver Straße 25-27 58515 Lüdenscheid Germany fon +49 (0) 2351/9365-0 fax +49 (0) 2351/936519 e-mail: info@ipf-electronic.com

More information

AZ420 MINIATURE GENERAL PURPOSE RELAY

AZ420 MINIATURE GENERAL PURPOSE RELAY MINIATURE GENERAL PURPOSE RELAY FEATURES Rugged construction for high reliability Life expectancy greater than 0 million operations DC coils to 11 V Power consumption as low as 2 mw per pole available

More information

RESOLUX / HIGHLITE/ COMPACT LINE Technology Lighting as its best. Designed and produced in Germany

RESOLUX / HIGHLITE/ COMPACT LINE Technology Lighting as its best. Designed and produced in Germany RESOLUX / HIGHLITE/ COMPACT LINE Technology Lighting as its best. Designed and produced in Germany RESOLUX 505 RESOLUX 650 RESOLUX 720 / 730 / 750 Application Suitable for high switching frequencies as

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

400 Series Buccaneer BUCCANEER POWER. bulgin

400 Series Buccaneer BUCCANEER POWER. bulgin bulgin BUCCANEER FOR POWER Contact Retainer Sealing Gasket O Ring Contacts Locking Ring Retaining Nut Panel Body Contacts Contact Carrier O Ring Main Body Cable Gland Collet Gland Nut Sealed to IP68 when

More information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information. Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an

More information

HMI Components. Series. Indicator Pushbutton Illuminated pushbutton. Machinery and Automation Building technology Panel building.

HMI Components. Series. Indicator Pushbutton Illuminated pushbutton. Machinery and Automation Building technology Panel building. Edition 02/2016 HMI s Series Characteristics The compact Series is especially suited for: Functions The Series incorporates the following functions: Market segments The EAO series is used in the following

More information

usb flash drives with logo delivery within 3 days

usb flash drives with logo delivery within 3 days usb flash drives with logo delivery within 3 days 2015 QUALITY We do our best to provide top quality products. We work with proven suppliers and carefully select our components. In addition, to make sure

More information

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34 LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34 2 LEVEL GAUGES WITH MAGNETIC JOINT SIZE Ø 140/220/340 58 58 TYPE LA TYPE LA 14 30 S 22 33 TYPE LA 22-34 NO. HOLES Ø D2 76 O-RING CENTRE OF THE CONSERVATOR

More information

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B,

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B, Accessories Temperature Sensors for Injection Molding Types 6192B, 6193B, 6194B, 6195B Temperature sensors for measuring the contact temperature directly in the cavity at the surface of the solidified

More information

Safety detection solutions

Safety detection solutions Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

08. SEK IDC CONNECTORS

08. SEK IDC CONNECTORS . IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these

More information

Model 201 Wiegand Touchpad Reader Installation Guide

Model 201 Wiegand Touchpad Reader Installation Guide Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without

More information

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 v.1.0 AC/AC power supply unit Edition: 1 from 24 th October 2008 Supercedes edition: ---------- 10062009 CONTENTS: 1. Technical description. 1.1. General description

More information

Fire Alarm System Plans Review Checklist Property location Date of Review

Fire Alarm System Plans Review Checklist Property location Date of Review Fire Alarm System Plans Review Checklist Property location Date of Review 1. Is application completed in entirety? 2. Are the plans review fee submitted with the application? 3. Does floor plan include

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

Line-Mounted Valves L Series

Line-Mounted Valves L Series Spare Part Kit for Valve Series B1LSAD3 Line-Mounted L Series Accessories Spare Part Kits All Series Valve Series B1LSAD3 40.1609 Incl. O-rings, gaskets, spring or muffl er Spare Part Kit for Valve Series

More information

Reference. 910 402 230 V, 50 Hz A10 415 120 V,60 Hz. 916 402 230 V, 50/60 Hz A16 418 120 V, 50/60 Hz. 910 103 230 V, 50 Hz A10 104 120 V, 60 Hz

Reference. 910 402 230 V, 50 Hz A10 415 120 V,60 Hz. 916 402 230 V, 50/60 Hz A16 418 120 V, 50/60 Hz. 910 103 230 V, 50 Hz A10 104 120 V, 60 Hz Rex - analog time switches MicroRex - 3 modules for DIN rail mounting Rex - analog time switches MicroRex - module for DIN rail mounting 926 428 A0 4 MicroRex T3 24 hour program, synchronous motor 92 429

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

Model Number Structure

Model Number Structure General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with

More information

CL001-V Classic swivel USB drive with silver clip. Available in 5 colors: white, orange (021C), blue (286C), black and red (185C).

CL001-V Classic swivel USB drive with silver clip. Available in 5 colors: white, orange (021C), blue (286C), black and red (185C). Page 1 Custom USB Drives Custom USB Drives Page 1 CL001-V Classic swivel USB drive with silver clip. Available in 5 colors: white, orange (021C), blue (286C), black and red (185C). CL001-S Classic swivel

More information

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-2 umodule SPOT PHASED OUT NTC

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-2 umodule SPOT PHASED OUT NTC Product description Spotlights Downlights High-flux LED module Narrow colour temperature tolerance band Compact design Excellent thermal management 1 NTC for temperature control High-power LED in chip-on-board

More information

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB , GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

How To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating

How To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating GB PKN10 serial node with colour LCD display User s manual Bač 49a, 6253 Knežak, SLOVENIA tel: ++ 386 5 753 2006 fax: ++ 386 5 753 2007 email: sec.electronics@siol.net http://www.secelectro.com SEC Electronics

More information

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P340-2 umodule SPOT PHASED OUT NTC 42.25 37 11 5.75 3.5 5.15 37.89 39.

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P340-2 umodule SPOT PHASED OUT NTC 42.25 37 11 5.75 3.5 5.15 37.89 39. Product description Spotlights Downlights High-flux LED module Narrow colour temperature tolerance band Compact design Excellent thermal management 1 NTC for temperature control High-power LED in chip-on-board

More information

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009 Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal

More information

2010-2011. Shortform Catalogue. Solutions for appliance & electronic applications. rocker switches. lever. switches. push. switches.

2010-2011. Shortform Catalogue. Solutions for appliance & electronic applications. rocker switches. lever. switches. push. switches. 2010-2011 Solutions for appliance & electronic applications Shortform Catalogue rocker lever push vandal resistant slide door snap-action & safety rotary IEC sockets fuseholders indicators A trading name

More information

Piezo Switch www.piezo-switch.com

Piezo Switch www.piezo-switch.com Piezo Switch www.piezo-switch.com langir piezo switch About Piezo Siwtches Conventional electromechanical switches have moving parts that inevitably wear out. The reliability of the electromechanical switches

More information

Contact expander modules

Contact expander modules Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.

More information

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529) Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Complete units. Complete underfloor box for one Modul 45 socket and two data connection sockets. Complete service outlets

Complete units. Complete underfloor box for one Modul 45 socket and two data connection sockets. Complete service outlets Complete underfloor box for one Modul 45 socket and two data connection sockets Screed height 105-165 mm In the field of complete service outlets, the GE 1 and GET 1 models are a universal, high-quality

More information

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL N2xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL SPECIFICATIONS Supply voltage N224A / N3424A N223A / N3423A PRODUCT DATA 24 Vac 15%, 5/6 Hz 23 Vac 15%,

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information