MT 42 / MA Touch plates/plates and rims. Fixture st. steel, brushed. Landing fixture brass, browned. Flat glass fixture

Size: px
Start display at page:

Download "MT 42 / MA 42 2.3. Touch plates/plates and rims. Fixture st. steel, brushed. Landing fixture brass, browned. Flat glass fixture"

Transcription

1 NSPRATONS MT / MA Touch plates/plates and rims Choice of faceplate materials Fixture st. steel, brushed Landing fixture brass, browned Flat glass fixture TiN-coating surface design Hairline TiN-coating matt MT touch plate and rim TiN-coating polished st. steel, black aluminium, black anodised AlMg3 EV6 st. steel, brushed st. steel, matt MT touch plate and rim st. steel, polished Landing fixture TiN-coating MT touch plate and rim st. steel, black Landing fixture st. steel, polished Update / Further touch plate/plate finishes available on demand REVSON b 2.3

2 TOUCH PLATE MARKNG MT neutral touch plate st. steel, matt neutral engraving touch plate st. steel, matt engraving (black, option: colour, RAL shades) height of characters 1 mm height of symbols 15 mm! Various X X laser pierced black pierced opal pierced yellow (translucent) touch plate st. steel, matt laser-marked height of characters 1 mm height of symbols 15 mm touch plate st. steel, matt pierced black (black injected) height of characters 1 mm (min. 5 mm) height of symbols 15 mm touch plate st. steel, matt pierced opal (white translucent injected) height of characters 1 mm (min 5 mm) height of symbols 15 mm touch plate st. steel, matt pierced yellow (yellow or yellow translucent injected) alarm symbol height of symbol 15 mm EN 81-7 embossing laser touch plate st. steel, matt embossing (laser-marked) height of characters 15 mm, with/without Braille height of symbols 18 mm, without Braille EN 81-7 embossing touch plate st. steel, black embossing (brightened) height of characters 15 mm, with/without Braille height of symbols 18 mm, without Braille Update / EN 81-7 embossing touch plate aluminium, black anodised (AlMg3 EV6) embossing (ground) height of characters 15 mm, with/without Braille height of symbols 18 mm, without Braille REVSON a 2.4 Further touch plate finishes available on demand

3 MT 2M XV Micro Button 2M XV Faceplate thickness Connection 2 mm... 3 mm, 1 mm/1.5 mm mit Unterlage.1 mm²... 1 mm² 3 4 AWG 28 (ribbon cable) Stroke snap switch 1 NO-contact switching voltage = 3 V DC switching current =.8 A ohmic load switching current =.5 A inductive load (L/R = 3 ms) switching voltage = 3 V AC switching current = 1 A snap switch 1 alternating contact switching voltage = 12 V DC switching current =.5 A ohmic load switching current =.2 A inductive load (L/R = 3 ms) switching voltage = 5 V AC switching current = 1 A 1.5 mm 12 V... 3 V AC/DC option 3 V V AC/DC 4 ma NO C C NO NC C NO pierced yellow neutral engraving/laser pierced yellow translucent embossing 2.11

4 MT V bishade Micro Button V, two-stage recall light Characteristics recall light full luminosity Faceplate thickness 2 mm... 3 mm, 1 mm/1.5 mm with spacer Connection.1 mm²... 1 mm² 2 4 Switching element print switch 1 NO-contact switching voltage =.2 V 3 V AC/ V DC switching current =.1 ma 5 ma switching capacity = 1 W Stroke.5 mm....8 mm Permanent illumination half luminosity 1 permanent illumination half luminosity 12 V... 3 V AC/DC option 3 V V AC/DC 1 ma 1 full luminosity 12 V... 3 V AC/DC option 3 V V AC/DC 45 ma Rear view PR A TS CT HE R Wiring diagram Cutout + _ C NO Update / REVSON a BR 2.12 neutral engraving/laser pierced black pierced opal embossing

5 MT X bishade Micro Button X, two-stage recall light Characteristics recall light full luminosity Faceplate thickness 2 mm 3 mm, 1 mm/1.5 mm with spacer Connection.1 mm²... 1 mm² 2 4 Switching element print switch 1 NO-contact switching voltage =.2 V 3 V AC/ V DC switching current =.1 ma 5 ma switching capacity = 1 W Stroke.5 mm....8 mm Permanent illumination half luminosity 1 permanent illumination half luminosity 12 V... 3 V AC/DC option 3 V V AC/DC 1 ma 1 full luminosity 12 V... 3 V AC/DC option 3 V V AC/DC 45 ma Rear view R P A TS CT HE R Wiring diagram Cutout + _ C NO Update / REVSON a neutral engraving/laser pierced black pierced opal embossing 2.13

6 MT V bicolour Micro Button V, two-coloured recall light Characteristics recall light Faceplate thickness 2 mm 3 mm, 1 mm/1.5 mm with spacer Connection.1 mm²... 1 mm² 2 4 Switching element print switch 1 NO-contact switching voltage =.2 V 3 V AC/ V DC switching current =.1 ma 5 ma switching capacity = 1 W Stroke.5 mm....8 mm Permanent 5 permanent illumination 12 V... 3 V DC option 3 V V DC 45 ma 5 12 V... 3 V DC option 3 V V DC 45 ma Rear view PR A TS CT HE R Wiring diagram Cutout 28 + _ C NO Update / REVSON a BR 2.13/1 neutral engraving/laser pierced black pierced opal embossing

7 MT X bicolour Micro Button X, two-coloured recall light Characteristics recall light Faceplate thickness 2 mm 3 mm, 1 mm/1.5 mm with spacer Connection.1 mm²... 1 mm² 2 4 Switching element print switch 1 NO-contact switching voltage =.2 V 3 V AC/ V DC switching current =.1 ma 5 ma switching capacity = 1 W Stroke.5 mm....8 mm Permanent 5 permanent illumination 12 V... 3 V DC option 3 V V DC 45 ma 5 12 V... 3 V DC option 3 V V DC 45 ma Rear view R P A TS CT HE R Wiring diagram Cutout + _ C NO Update / REVSON a neutral engraving/laser pierced black pierced opal embossing 2.13/2

8 REVSON a Update /

9 MT fb Micro Button, remotely operated Function Faceplate thickness Connection remotely operated function test e. g. for alarm button or door open button 2 mm... 3 mm, 1 mm/1.5 mm with spacer.1 mm²... 1 mm² fb = remotely operated remotely operated function test e. g. - alarm button - door open button Switching element snap switch 1 NO-contact/1 alternating contact switching voltage = 3 V DC switching current =.8 A ohmic load switching current =.5 A inductive load (L/R = 3 ms) switching voltage = 5 V AC switching current = 1 A Coil UB = 2 V DC... 3 V DC Power consumption with remote operation max. 3 ma Keying time for remote operation max. 4 seconds Stroke.5 mm....8 mm 3 V AC/DC option 12 V AC/DC 2 ma PR A TS CT HE R C NO NC C NO L S1 S2 Update / REVSON a neutral engraving/laser embossing 2.15

10 MT ndividual configuration ndividual Configurations llustration / detail Wiring diagram T1 D1 MT RUS H1 18 D2 18 D3 SC! Female connector not supplied 4 1 C NO MT TH 2.16

11 PLATE MARKNG MA neutral plate st. steel, matt neutral engraving plate st. steel, matt engraving (black, option: colour, RAL shades) height of characters 1 mm height of symbols 15 mm! Various X X laser plate st. steel, matt laser-marked height of characters 1 mm height of symbols 15 mm pierced opal film plate st. steel, matt pierced opal (white translucent injected) height of characters 1 mm (min. 5 mm) height of symbols 15 mm polycarbonate plate, crystal clear or red square, 3 mm x 3 mm film (positive, negative, colour) height of characters 1 mm height of symbols 15 mm injected plate st. steel, matt square, 3 mm x 3 mm injected opal (arrows white translucent injected) height of symbol 12 mm REVSON a Update / Further plate finishes available on demand

12 MA M V Micro ndicator, metal V Faceplate thickness 2 mm 3 mm, 1 mm/1.5 mm with spacer Connection AWG V AC/DC option 12 V AC/DC 2 ma PR A TS CT HE R neutral engraving/laser pierced opal

13 MA M V Micro ndicator, metal V Faceplate thickness Connection 2 mm 3 mm, 1 mm/1.5 mm with spacer.1 mm²... 1 mm² 4 3 V AC/DC option 12 V AC/DC 2 ma R P A TS CT HE R neutral engraving/laser pierced opal 2.

14 MA P V Micro ndicator, plastic V Faceplate thickness 2 mm 3 mm, 1 mm/1.5 mm with spacer Connection AWG Plate crystal clear red Film positive, negative, colour 3 V AC/DC option 12 V AC/DC 2 ma R 1.43 PR A TS CT HE R Update / REVSON a 2.2 film film

15 MA P V Micro ndicator, plastic V Faceplate thickness Connection 2 mm 3 mm, 1 mm/1.5 mm with spacer.1 mm²... 1 mm² 4 Plate crystal clear red Film positive, negative, colour 3 V AC/DC option 12 V AC/DC 2 ma R 1.43 PR A TS CT HE R Update / Markierung REVSON a film film 2.21

16 MA M X Micro ndicator, metal X Faceplate thickness 2 mm 3 mm, 1 mm/1.5 mm with spacer Connection AWG 28 (ribbon cable) 4 12 V... 3 V AC/DC option 3 V V AC/DC 4 ma PR A TS CT HE R neutral engraving/laser pierced opal

17 MA P X Micro ndicator, plastic X MA P X plate red Faceplate thickness 2 mm... 3 mm, 1 mm/1.5 mm with spacer Connection AWG 28 (ribbon cable) 4 Plate crystal clear red Film positive, negative, colour MA P X plate crystal clear 12 V... 3 V AC/DC option 3 V V AC/DC 4 ma R 1.43 PR A TS CT HE R 75 3 Update / REVSON a film film 2.23

18 MA P V LC Micro ndicator, plastic V recall light emergency call released Low Current Faceplate thickness 2 mm... 3 mm, 1 mm/1.5 mm with spacer Connection AWG Plate Film crystal clear negative, colour recall light emergency call acknowledged Compliance EN 81-7 EN V DC smoothed 2.5 ma R 1.43 current ma 1mA 2mA power consumption V 5V 1V 15V 2V 25V 3V voltage PR A TS CT HE R Update / _ REVSON a 2.24 film

19 MA P V LC Micro ndicator, plastic V Low Current recall light emergency call released Faceplate thickness Connection 2 mm... 3 mm, 1 mm/1.5 mm mit Unterlage 2.1 mm²... 1 mm² Plate Film crystal clear negative, colour recall light emergency call acknowledged Compliance EN 81-7 EN V DC smoothed 2.5 ma R 1.43 current ma 1mA 2mA power consumption V 5V 1V 15V 2V 25V 3V voltage R P A TS CT HE R _ Update / REVSON a film 2.25

20 MA W V Micro ndicator, motion V MA W intermediate stop Faceplate thickness 2 mm... 3 mm, 1 mm/1.5 mm with spacer Connection AWG arrow up/down (intermediate stop) 3 V AC/DC option 12 V AC/DC 2 ma (per arrow) MA W terminal stop arrow up or down (terminal stop) 3 V AC/DC option 12 V AC/DC 4 ma intermediate stop R P A TS CT HE R arrow up arrow down L3 L4 REVSON a 2.26 injected injected

Further materials as well as handling of externally supplied materials on demand III

Further materials as well as handling of externally supplied materials on demand III Faceplates and mounting options Faceplate Materials The first impression is important even with fixtures. The choices of faceplate materials play an essential role. Ground stainless steel, gold-coloured

More information

Q SERIES Ø14mm (.551") Panel Mount LED Indicators Distinctive features and specification

Q SERIES Ø14mm (.551) Panel Mount LED Indicators Distinctive features and specification Distinctive features and specification Q14_VOY1609R2US Features 14mm panel mounting LED indicator 10mm colored diffused epoxy lens or 10mm water clear super bright LEDs Plated brass bezel finished in bright

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...

More information

HARTING Ethernet Cabling 8-poles Overview

HARTING Ethernet Cabling 8-poles Overview Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs

More information

DCP Fan Controller. Version 01/2009. The engineer s choice

DCP Fan Controller. Version 01/2009. The engineer s choice Version 01/2009 The engineer s choice Index Page 1. Introduction... 3 2. Technical specification... 4 3. Connection diagrams... 9 4. Configuration... 10 5. Compatible ebm-papst Fan List... 11 2 1. Introduction

More information

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions Disabled Toilet Alarm Installation & Operating Contractor Pack Installation & Operating Instructions 1 Overview The Channel Safety Systems Disabled Toilet alarm contractor Packs are an efficient way of

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

www.sebury.com.cn Digital Keypad Use s Manual

www.sebury.com.cn Digital Keypad Use s Manual K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS Photoelectric These sensors use light sensitive elements to detect objects and are made up of an emitter (light source) and a receiver. Four types of photoelectric

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

BANDE. switch panel with flat push-button. cjcsystems com

BANDE. switch panel with flat push-button. cjcsystems com BANDE switch panel with flat push-button cjcsystems com 48 switch panels 230v CJC5581A 1 push-button CJC5582A 2 push-buttons CJC5584A 4 push-buttons 118 x 85 x 6 In built-in boxes type TICINO503e wiring

More information

PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. PSDC 08128 v.1.2 PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. EN** Edition: 9 from 25.05.2015 Supersedes the edition: 8 from 12.12.2014 the 8x 1A/12V DC power output for powering

More information

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color) Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum

More information

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently (68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please

More information

N&H Technology GmbH. Silicone Rubber Keypad. Single Source Supply. Design Guide - Short Version. Engineering in Germany - Production in East Asia

N&H Technology GmbH. Silicone Rubber Keypad. Single Source Supply. Design Guide - Short Version. Engineering in Germany - Production in East Asia N&H Technology GmbH Import & Export of Industrial Products Technical Support and Engineering Business Consulting and Representation Silicone Rubber Keypad Design Guide - Short Version Single Source Supply

More information

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad) KCIENSBP KCIEN Heavy Duty Stainless Steel Illuminated Keypads Range: DIGICODE (Stand-Alone Keypad) INSTALLATION MANUAL Features: Input voltage: 12V to 24V AC or 12V to 48V DC Illuminated keys Heavy duty

More information

Power supply 142. Couplers 143. Data interfaces 144. Accessories 145

Power supply 142. Couplers 143. Data interfaces 144. Accessories 145 KNX system units The system components are KNX devices, which assume higher-level functions, independent of the application. They guarantee the necessary infrastructure in the building, ensuring a flawless

More information

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB , GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access CSP Combined Series Telephone Door Entry with Proximity Keyfob Access PD-094 Issue 3 General Description The CSP series systems are combined Door Entry Telephone and Proximity Access Systems. The entrance

More information

Variety of Control Options Control is possible via wall switches, remote control systems or integration into building management systems.

Variety of Control Options Control is possible via wall switches, remote control systems or integration into building management systems. Breezway Altair Powerlouvre Window 35 Breezway Altair Powerlouvre Window The Powerlourve Window motor is neatly concealed within the Easyscreen TM Frame or the Component Powerlouvre Head Section. Automated

More information

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design .8 Ex-Recess-mounted, ceiling emergency light fittings in compact metal design RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX 50... N 18-36 W (Zone 1,, 1, ) The explosion-protected lighting concept for clean rooms

More information

ABLOY EL614 Motor lock with bolt Abloy Oy An ASSA ABLOY Group company EL614 42/52 25/35 25 22 263.5 225 38.2 17.3 3 10 2 Contents TECHNICAL DATA... 4 INSTALLATION... 5 WIRING DIAGRAM... 6 DRILLING SCHEME...

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

Magnetic Proximity Switches Series CST - CSV and CSH

Magnetic Proximity Switches Series CST - CSV and CSH Magnetic Series CST - CSV and CSH Reed, Electronic»» Designed to fit into the cylinder profile barrel»» 3 models (CST - CSV - CSH) are suitable for all Camozzi s cylinder range»» With or without M8 connector

More information

TECHNISCHE FICHE - TECHNISCHE FICHE - Chat Board: Classic

TECHNISCHE FICHE - TECHNISCHE FICHE - Chat Board: Classic - TECHNISCHE FICHE - Chat Board: Classic Classic is a magnetic glass- and writing board for use in modern offices and private homes. CHATBOARD Classic is Danish Design - made in Denmark. Classic is a glass

More information

COMPALARM AP GENERAL MAIN FEATURES

COMPALARM AP GENERAL MAIN FEATURES GENERAL The COMPALARM AP is a point alarm system, with as many normally closed input contacts. It givesthe possibility of selecting the alarm sequence according with 0 x 0 mm cells, fitted with ultra bright

More information

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

ZMR 80 STEREO MODULAR ZONER USERS MANUAL ZMR 80 STEREO MODULAR ZONER USERS MANUAL Lime Technologies http://limetechnologies.co.uk Tel: 08712 233127 ZMR80 Stereo Modular Zoner Mixer Introduction The modular construction of the ZMR80 allows it

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T Universal industry standard encoder Up to 40 000 steps with 0 000 pulses High signal accuracy Protection class up to IP67 Flexible due to many flange and configuration variants Suitable for high shock

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050 Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage

More information

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation

More information

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch 2 Wire Electronic Time Delay Switch Cat No. DS1 2 Wire Slave Switch Cat No. DSS 3 Wire Electronic Time Delay Switch Cat No. DS2 Installation & Operating Instructions DS1/DSS Instructions for Installation

More information

KONE EN81-71 CAtegory 1. Vandal Resistant Lift

KONE EN81-71 CAtegory 1. Vandal Resistant Lift KONE EN81-71 CAtegory 1 Vandal Resistant Lift Car Finishing Options: MonoSpace Standard Ceilings LF94 Doors Asturias Satin (F) Walls Stainless steel Asturias Satin (F) Flemish Linen (M) Scottish Quad (K)

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 v.1.0 AC/AC power supply unit Edition: 1 from 24 th October 2008 Supercedes edition: ---------- 10062009 CONTENTS: 1. Technical description. 1.1. General description

More information

HCR3.2/.. Chipcard reader HOTEL SOLUTION

HCR3.2/.. Chipcard reader HOTEL SOLUTION s 6 332 HOTEL SOLUTION Chipcard reader HCR3.2/.. Chipcard reader for hotel room access control Reads access code on chipcard Transfers access code to room controller Built-in optical display of messages

More information

ATL Fuel Level Sender Probes

ATL Fuel Level Sender Probes T E C H N I C A L S P E C I F I C A T I O N The ATL EL-AD-151 (Resistance Output) and EL-AD-152 (Voltage Output) Fuel Level Senders are highly advanced sensors for continuously measuring the contents of

More information

Fire Alarm System Plans Review Checklist Property location Date of Review

Fire Alarm System Plans Review Checklist Property location Date of Review Fire Alarm System Plans Review Checklist Property location Date of Review 1. Is application completed in entirety? 2. Are the plans review fee submitted with the application? 3. Does floor plan include

More information

13 SERIES. Electronic step relays 10-16 A 13.81 13.91

13 SERIES. Electronic step relays 10-16 A 13.81 13.91 13 Electronic step relays 10-16 A 13 13.81 - Electronic step relay - Rail mount - 1 Pole 13.91 - Electronic step relay and timing step relay Switch box mount - 1 Pole Fixed time (10 minutes) timing function

More information

instabus KNX / EIB System System E F G H

instabus KNX / EIB System System E F G H Product name: Uninterruptible power supply (USV) 640 ma Design: REG (rail-mounted device) Article-no.: 1079 00 ETS search path: Gira Giersiepen / system components / power supply / power supply 640mA DRA

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

Switches & Pilot Devices

Switches & Pilot Devices Key features: 21/4 (8mm) round mounting hole Compact Design Saves Space Bright and Vivid Illumination Choice of Shapes and Functions old Clad Silver Contacts for reliable low level switching Snap action

More information

Contrast 2 LED. Performance Compactness Complete flexibility NEW

Contrast 2 LED. Performance Compactness Complete flexibility NEW NEW Contrast 2 LED High light output in a compact and discreet design with a wide choice of light effects created using different light distributions and accessories Performance Compactness Complete flexibility

More information

Mureva Assembly surface mounted wiring devices

Mureva Assembly surface mounted wiring devices 1.0 Waterproof Assembly surface Switches P124543 P124547 External dimensions : 72 x 72 x 47 mm.. Assembly surface rockers become illuminated using bulbs and indicators in option. They can carry a label

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Lighting Packages. 230 VAC Fluorescent Enclosure Light: Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for

More information

RGB Light Panel Applications. RGB LED Light Panel FEATURES & BENEFITS SPECIFICATION SHEET

RGB Light Panel Applications. RGB LED Light Panel FEATURES & BENEFITS SPECIFICATION SHEET RGB LED Light Panel E346146 E325925 FEATURES & BENEFITS AVAILABLE IN CUSTOM SIZES & SHAPES CAN BE USED IN FRAMELESS DESIGNS 3D V-CUTTING TECHNOLOGY MULTI-COLOR OPTION HIGH BRIGHTNESS (2,000-10,000 LUX)

More information

DECORATIVE RANGES PENDANTS FLUSH FITTINGS WALL LIGHTS TABLE & FLOOR BATHROOM SPOTLIGHTS & DOWNLIGHTS LED STRIPLIGHTS OUTDOOR LED LIGHTING

DECORATIVE RANGES PENDANTS FLUSH FITTINGS WALL LIGHTS TABLE & FLOOR BATHROOM SPOTLIGHTS & DOWNLIGHTS LED STRIPLIGHTS OUTDOOR LED LIGHTING DECORATIVE RANGES PENDANTS WALL LIGHTS TABLE & FLOOR BATHROOM SPOTLIGHTS & DOWNLIGHTS LED STRIPLIGHTS OUTDOOR LED LIGHTING LOW ENERGY LIGHTING LAMPS 235 _72134 supplement 2012_v4_72134 supplement 2012

More information

DCS Input/Output Relay Card Series

DCS Input/Output Relay Card Series Input/Output Relay Card Series I/O RELAY CARD (with loopback test function) 8N The 8N series I/O Relay Cards easily and quickly standardize and facilitate installation of the relay board. Loopback test

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

08. SEK IDC CONNECTORS

08. SEK IDC CONNECTORS . IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these

More information

LED MACHINE ILLUMINATIONS

LED MACHINE ILLUMINATIONS white LED light industrial-suited housing energy-efficient ipf electronic gmbh Kalver Straße 25-27 58515 Lüdenscheid Germany fon +49 (0) 2351/9365-0 fax +49 (0) 2351/936519 e-mail: info@ipf-electronic.com

More information

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable Port side cable (with black cable tie attached) Power cable Preparing for Installation 1 Overall

More information

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000 Security Alarm Central Unit 3 4 Technical KNX Alarm central unit EAM 4000 ETS-product family: Alarm system Product type: Alarm central unit The alarm central unit is a modern alarm system using the KNX

More information

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX The Lantana Luminaire linear light fixture is designed to seamlessly integrate with compatible Lutron control systems. It can be easily

More information

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring

More information

COOL Shelf Quick Connect

COOL Shelf Quick Connect Refrigeration equipment Shelf lighting High efficiency COOL QCS Quick-Connection-System Dimmable Various lengths Neutral White Warm White Pasta & Cheese Fresh Meat Packed Meat 1 A COOL Shelf Quick Connect

More information

STANDARD MICRO-D CONNECTORS

STANDARD MICRO-D CONNECTORS STANDARD MICRO-D CONNECTORS RECTANGULAR CONNECTORS Pigtail connector - Metal shell.............................. 56 Pigtail connector - Low profile - Metal shell.................... 58 Pigtail connector

More information

Cover Page. Factory Radio Other Documents Available For This Vehicle:

Cover Page. Factory Radio Other Documents Available For This Vehicle: & nstall Publication, Duplication, or Retransmission Of This Document Not Expressly Authorized n Writing By The nstall Doctor s Prohibited. Protected By U.S. Copyright Laws. 1997,1998,,2000. Factory Radio

More information

Inductive Proximity Sensors

Inductive Proximity Sensors M12 Inductive Proximity Sensors Standard Length Mini's Extended Sensing 3 Wire DC 2 Wire DC 2 Wire AC (Wiring Schematic) 3 Wire DC PNP Normally Open (1) IMM32122C IMM35124C IMN32122C IMN35124C IMN32122M12

More information

Color Mark Sensor with Red or Green LED E3S-VS

Color Mark Sensor with Red or Green LED E3S-VS Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical

More information

How To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating

How To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating GB PKN10 serial node with colour LCD display User s manual Bač 49a, 6253 Knežak, SLOVENIA tel: ++ 386 5 753 2006 fax: ++ 386 5 753 2007 email: sec.electronics@siol.net http://www.secelectro.com SEC Electronics

More information

PNOZsigma - Base units

PNOZsigma - Base units PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable

More information

IEC Connectors. Introduction

IEC Connectors. Introduction Introduction IEC Connectors A full range of quality mains rated inlets, outlets and connectors conforming to IEC and EN 60320 specifications carrying UL, CSA, VDE and other approvals. With electrical ratings

More information

USB 3.0 Cables. Color. Black Black Black Black Black 3021003-03 3021009-06 3021015-10 3021021-16 3021027-16. Black Black Black Black Black

USB 3.0 Cables. Color. Black Black Black Black Black 3021003-03 3021009-06 3021015-10 3021021-16 3021027-16. Black Black Black Black Black USB.0 CableS USB.0 and backwards compatible for USB.0 and. Supports high speed, 480Mbps Twisted-pair construction reduces cross talk to ensure error free transfer USB A male to USB B male 00-0 007-0 0-09-

More information

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000. NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24

More information

Switches SWITCHES SWITCHES

Switches SWITCHES SWITCHES Switches Manufactured from Stainless Steel, Bulgin s extensive range of vandal resistant security switches are designed with a high resistance to wear and tear, corrosion and harsh use in potentially hostile

More information

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL ATS-220 AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL For Use in 208 to 240 Volts Single and 3 Phase ATS Systems With 110Volt AC or DC Control Motors and selenoids 4501 NW 27 ave Miami FL 33142

More information

Garage Sectional Doors

Garage Sectional Doors Garage Sectional Doors FROM TECKENTRUP TOP CLASS QUALITY DOORS MADE OF STEEL; ALUMINIUM OR WOOD W E O P E N T H E D O O R S F O R P R O G R E S S ECONOMICAL AND SPACE-SAVING FOR EVERY STRUCTURAL SITUATION

More information

Emergency Voice Communication Systems EVCS Network 8 Data Sheet

Emergency Voice Communication Systems EVCS Network 8 Data Sheet Emergency Voice Communication Systems EVCS Network 8 Data Sheet The Emergency Voice Communications System (EVCS) Network 8 is for use as a Fire Telephone system, Disabled Refuge Call system or as a combined

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

Sento LED parete singolo up cutsheet

Sento LED parete singolo up cutsheet 0.2m Sento LED parete singolo up cutsheet LED wall mounted luminaire with a high base, in which the power supply unit (converter) is included for mounting on fixed ceiling or wall, connection to 230V.

More information

Roadstar Installation Instruction Manual

Roadstar Installation Instruction Manual Roadstar Installation Instruction Manual This instruction manual describes installation of GPS/GPRS vehicle tracking device Roadstar. Modem is already set to work with system for vehicle tracking, and

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS FRANCE Head office USA 4 Rue du Bois Chêne le loup Parc d Activité de Brabois 54 500 VANDOEUVRE LES NANCY (33) 0383442413, Fax (33) 0383443797

More information

Fading Red Tones on Color LaserJet 2600s

Fading Red Tones on Color LaserJet 2600s Procedures Fading Red Tones on Color LaserJet 2600s HP Color LaserJets 2600n, 1600, and 2605 share the same basic Canon engine design. One aspect of the design brings the common problem of scanner optic

More information

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009 Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal

More information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information. Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an

More information

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector

More information

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service

More information

GSM home alarm system s manual

GSM home alarm system s manual GSM home alarm system s manual I. Main features: 1, Eight wireless LED zone, and four wired zone 2, Two-way to communication 3, The system supports the GSM cell phones, no need the fixed telephone line.

More information

HMI Components. Series. Indicator Pushbutton Illuminated pushbutton. Machinery and Automation Building technology Panel building.

HMI Components. Series. Indicator Pushbutton Illuminated pushbutton. Machinery and Automation Building technology Panel building. Edition 02/2016 HMI s Series Characteristics The compact Series is especially suited for: Functions The Series incorporates the following functions: Market segments The EAO series is used in the following

More information

Undercounter & Slimline Cabinet Range HR/LR 120 HRB/LRB120 HR/LR 140 HR/LR 150 HR/LR 200 HR/LR 240 HR/LR 360 HR/LR 410

Undercounter & Slimline Cabinet Range HR/LR 120 HRB/LRB120 HR/LR 140 HR/LR 150 HR/LR 200 HR/LR 240 HR/LR 360 HR/LR 410 Undercounter & Slimline Cabinet Range HR/LR 120 HRB/LRB120 HR/LR 140 HR/LR 150 HR/LR 200 HR/LR 240 HR/LR 360 HR/LR 410 CONTENTS PAGE Introduction 1 to 2 2. Controller and operation 3 to 4 3. Controller

More information

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders

More information

usb flash drives with logo delivery within 3 days

usb flash drives with logo delivery within 3 days usb flash drives with logo delivery within 3 days 2015 QUALITY We do our best to provide top quality products. We work with proven suppliers and carefully select our components. In addition, to make sure

More information

Contractors Guide Central Inverter System Installation

Contractors Guide Central Inverter System Installation Contractors Guide Central Inverter System Installation Step By Step Procedures 2,200 Watt/VA 6 Step Installation 1. Mount Bottom Cabinet 2. Mount Top Cabinet 3. Install Batteries 4. Install Conduit 5.

More information

Instruction Manual for Operating Panel 301 and 302

Instruction Manual for Operating Panel 301 and 302 Instruction Manual for Operating Panel 301 and 30 Edition: 1/006 Edition: 1/006 Contents 1 Introduction and Overview........................ 5 1.1 Panel 301 Controls........................................

More information

CB200W Water Leak Detection Panel Application Guide

CB200W Water Leak Detection Panel Application Guide Checked by: AJC Approved by: JBJ Contents CB200W Water Leak Detection Panel Application Guide 1. Cabinet Specifications... 2 2. Panel Hardware Specifications... 3 3. Panel Configuration... 4 4. Technical

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs

More information

DECORATIVE RANGES PENDANTS FLUSH FITTINGS WALL LIGHTS TABLE & FLOOR BATHROOM SPOTLIGHTS & DOWNLIGHTS LED STRIPLIGHTS OUTDOOR LED LIGHTING

DECORATIVE RANGES PENDANTS FLUSH FITTINGS WALL LIGHTS TABLE & FLOOR BATHROOM SPOTLIGHTS & DOWNLIGHTS LED STRIPLIGHTS OUTDOOR LED LIGHTING DECORATIVE RANGES PENDANTS FLUSH FITTINGS WALL LIGHTS TABLE & FLOOR BATHROOM SPOTLIGHTS & DOWNLIGHTS LED STRIPLIGHTS OUTDOOR LED LIGHTING LOW ENERGY LIGHTING LAMPS 131 Arch LED / / Banker s Touch anywhere

More information

SMS 4 / SMS 5 safety mat Product information

SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,

More information