IEC / EN TEST REPORT FOR abgn MINICARD MODEL NUMBER: AR5BXB72 REPORT NUMBER: 06U ISSUE DATE: JULY 10, 2006

Size: px
Start display at page:

Download "IEC 60950-1 / EN 60950-1 TEST REPORT FOR. 802.11abgn MINICARD MODEL NUMBER: AR5BXB72 REPORT NUMBER: 06U10365-11 ISSUE DATE: JULY 10, 2006"

Transcription

1 IEC / EN TEST REPORT FOR abgn MINICARD MODEL NUMBER: AR5BXB72 REPORT NUMBER: 06U ISSUE DATE: JULY 10, 2006 Prepared for ATHEROS COMMUNICATIONS, INC GREAT AMERICA PARKWAY SANTA CLARA, CA 95054, U.S.A. Prepared by 561F MONTEREY ROAD, MORGAN HILL, CA 95037, U.S.A. TEL: (408) , FAX: (408)

2 Revision History Rev. -- Issue Date Revisions Revised By Initial Issue -- Page 2 of 17

3 TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS TEST METHODOLOGY FACILITIES AND ACCREDITATION CALIBRATION MEASURING INSTRUMENT CALIBRATION TEST AND MEASUREMENT EQUIPMENT EQUIPMENT UNDER TEST DESCRIPTION OF EUT DESCRIPTION OF MODEL DIFFERENCES RESULTS GENERAL REMARKS TEST RESULTS TABLE PHOTOS Page 3 of 17

4 1. ATTESTATION OF TEST RESULTS COMPANY NAME: EUT DESCRIPTION: MODEL: SERIAL NUMBER: ATHEROS COMMUNICATIONS, INC GREAT AMERICA PARKWAY, SANTA CLARA CA 95054, U.S.A abgn Minicard AR5BXB72 6F62001AYVZ6E DATE TESTED: July 7, 2006 APPLICABLE STANDARDS STANDARD IEC :2001 First Edition / EN :2001, First Edition TEST RESULTS NO NON-COMPLIANCE NOTED Compliance Certification Services, Inc. tested the above equipment in accordance with the requirements set forth in the above standard. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Note: The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. This document may not be altered or revised in any way unless done so by Compliance Certification Services and all revisions are duly noted in the revisions section. Any alteration of this document not carried out by Compliance Certification Services will constitute fraud and shall nullify the document. No part of this report may be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any government agency. Approved & Released For CCS By: Tested By: HSIN FU SHIH SAFETY ENGINEER OLIVER SU SAFETY ENGINEERING SUPERVISOR Page 4 of 17

5 2. TEST METHODOLOGY All tests were performed in accordance with the procedures documented in IEC :2001, First Edition Information technology equipment Safety Part 1: General requirements and EN :2001, First Edition Information technology equipment Safety Part 1: General requirements. 3. FACILITIES AND ACCREDITATION The test sites and measurement facilities used to collect data are located at 561F Monterey Road, Morgan Hill, California, USA. CCS is accredited by NVLAP, Laboratory Code The full scope of accreditation can be viewed at 4. CALIBRATION 4.1. MEASURING INSTRUMENT CALIBRATION The measuring equipment utilized to perform the tests documented in this report has been calibrated in accordance with the manufacturer's recommendations, and is traceable to recognized national standards. Page 5 of 17

6 4.2. TEST AND MEASUREMENT EQUIPMENT The following test and measurement equipment was utilized for the tests documented in this report: TEST EQUIPMENT LIST Description Manufacturer Model Serial Number Cal Due AC Power Source, 8 kva APC AFP2-8KVA J5061 CNR Hi-Pot Tester Associated Research 3570D /3/2007 Force Guage Chatillon DPP-25 3/19/2007 Ball Pressure Tester ED&D BPT-01 CNR Test Finger ED&D CNR Test Finger ED&D CNR Test Finger ED&D CNR Test Hook ED&D TH-01 CNR Test Pin Probe ED&D TPP-01 CNR Rigid Finger Probe ED&D UFD-01 CNR Multimeter Fluke /18/2008 True RMS Multimeter Fluke 26III /28/2006 True RMS Multimeter Fluke 26III /28/2006 Current Clamp Fluke i /5/2006 DC power supply Harrision/HP 6268A 6M1457 NCR Isolation Transformer HP NCR Electronic Load Kikusui PLZ152W /29/2006 Electronic Load Kikusui PLZ152W /4/2007 Electronic Load Kikusui PLZ300W /30/2006 Electronic Load Kikusui PLZ300W /4/2007 Electronic Load Kikusui PLZ300W /4/2007 Electronic Load Kikusui PLZ300W /4/2007 Digimatic Micrometer, 1 Inch Mitutoyo /19/2008 Digital Caliper, 6 Inches Mitutoyo /18/ /30 Amp Impedance Tester PSC INC. 30D /3/2007 Leakage Current Meter Simpson /3/2007 Powerstat ( Variac ) Superior 1256D NCR Probe, 100X Tektronix P5100 1/19/2008 Oscilloscope Tektronix TDS210 B /18/2008 Digital Power Analyzer Valhalla 2111A /6/2007 Digital Power Analyzer Valhalla 2111A /18/2008 Survey Meter WNB Johnson TVX-1B 8298 CNR Temperature Recorder Yokogawa HR1300/DC 45VH0276 9/29/2006 Temperature Recorder Yokogawa HR1300/DC 40VH0616 1/12/2007 Scale Pelouze /14/2006 Page 6 of 17

7 5. EQUIPMENT UNDER TEST 5.1. DESCRIPTION OF EUT This product is a abgn Minicard. TEST ITEM DESCRIPTION Trademark Manufacturer Model and/or type reference Serial number Rating(s) ATHEROS 5480 Great America Parkway, Santa Clara, CA 95054, USA AR5BXB72 6F62001AYVZ6E 3.3 V dc MAXIMUM NORMAL LOAD The EUT was energized Transmitting continuously, a/g mode, 6 Mbps, Target power = 17. PARTICULARS: TEST ITEM VS. TEST REQUIREMENTS Equipment mobility movable Operating condition continuous Mains supply tolerance (%) Not applicable (due to DC voltage input) Tested for IT power systems No IT testing, phase-phase voltage Not applicable (due to DC voltage input) (V) Class of equipment Class III Maximum Operating 35 Temperature (Tma, deg C) Mass of equipment (kg) < 1 Protection against ingress of IPX0 water TESTING Date of receipt of test item July 7, 2006 Date(s) of performance of test July 7, 2006 Page 7 of 17

8 5.2. DESCRIPTION OF MODEL DIFFERENCES (Null). Page 8 of 17

9 6. RESULTS 6.1. GENERAL REMARKS see enclosure # refers to additional information appended to the report. see appended table refers to a table appended to the report. Throughout this report a point is used as the decimal separator. TEST CASE VERDICTS Test case does not apply to the test object Test item does meet the requirement Test item does not meet the requirement N (Not Applicable) P (Pass) F (Fail) 6.2. TEST RESULTS IEC / EN Clause Requirement Test Result Remark Verdict 1 GENERAL P 1.5 Components P Comply with IEC or relevant component standard Components, which were found to affect safety aspects, comply with the requirements of this standard or within the safety aspects of the relevant IEC component standards. (see appended table 1.5.1) P 1.6 POWER INTERFACE P AC power distribution systems Class III equipment The equipment is powered by SELV DC source from internal Minicard slot connector of Notebook PC or Laptop PC Input current Optional P Page 9 of 17

10 IEC / EN Clause Requirement Test Result Remark Verdict 1.7 MARKING AND INSTRUCTIONS P Power rating The unit is not provided with a means for direct connection to an AC MAINS SUPPLY or a DC MAINS SUPPLY, it needs not be marked with any electrical rating, such as its RATED VOLTAGE, RATED CURRENT or RATED FREQUENCY. P 2 PROTECTION FROM HAZARDS P 2.1 Protection from electric shock and energy hazards P Protection in operator access areas Class III equipment The equipment is powered by SELV DC source from internal Minicard slot connector of Notebook PC or Laptop PC. P 2.2 SELV circuits P Voltages under normal conditions (V)... All circuitries are SELV, its voltages are less than 42.4V peak or 60V dc, under normal operation. P 2.3 TNV circuits 2.4 Limited current circuits 2.5 Limited power sources 2.6 Provisions for earthing and bonding 2.7 Overcurrent and earth fault protection in primary circuits 2.8 Safety interlocks 2.9 Electrical insulation Page 10 of 17

11 IEC / EN Clause Requirement Test Result Remark Verdict 2.10 Clearances, creepage distances and distances through insulation 3 WIRING, CONNECTIONS AND SUPPLY 3.2 Connection to an a.c. mains supply or a d.c. mains supply 3.3 Wiring terminals for connection of external conductors 3.4 Disconnection from the mains supply 3.5 Interconnection of equipment 4 PHYSICAL REQUIREMENTS 4.1 Stability 4.2 Mechanical strength 4.3 Design and construction 4.4 Protection against hazardous moving parts - No hazardous moving parts for this equipment 4.5 Thermal requirements P 4.6 Openings in enclosures 4.7 Resistance to fire Connectors in SECONDARY CIRCUITS supplied by power sources, which are limited to a maximum of 15 VA for this equipment. P 5 ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS 5.1 Touch current and protective conductor current 5.2 Electric strength Page 11 of 17

12 IEC / EN Clause Requirement Test Result Remark Verdict 5.3 Abnormal operating and fault conditions 6 CONNECTION TO TELECOMMUNICATION NETWORKS Equipment is not connected to TNV Circuit 6.1 Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment 6.2 Protection of equipment users from overvoltages on telecommunication networks 6.3 Protection of the telecommunication wiring system from overheating 7 CONNECTION TO CABLE DISTRIBUTION SYSTEMS A ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE B ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS (see and 5.3.2) C ANNEX C, TRANSFORMERS (see and 5.3.3) D ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS E ANNEX E, TEMPERATURE RISE OF A WINDING F ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES (see 2.10) G ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM CLEARANCES H ANNEX H, IONIZING RADIATION (see ) J ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see ) K ANNEX K, THERMAL CONTROLS (see and 5.3.7) Page 12 of 17

13 IEC / EN Clause Requirement Test Result Remark Verdict L ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL BUSINESS EQUIPMENT (see and 4.5.1) M ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1) N ANNEX N, IMPULSE TEST GENERATORS (see , , and clause G.5) P ANNEX P, NORMATIVE REFERENCES Q ANNEX Q, BIBLIOGRAPHY R ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL PROGRAMMES S ANNEX S, PROCEDURE FOR IMPULSE TESTING (see ) T ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER (see 1.1.2) U ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED INSULATION (see ) Page 13 of 17

14 IEC / EN Clause Requirement Test Verdict 6.3 TABLE TABLE: list of critical components P object/part No. manufacturer/ trademark type/model technical data standard mark(s) of conformity 1 ) PCB Various Various 94V-0, 105 C UL796 UL 1 ) an asterisk indicates a mark which assures the agreed level of surveillance TABLE: electrical data (in normal conditions) AC Input (from main power source) fuse # Irated (ma) U (V) P (W) I (ma) Ifuse (ma) condition/status TABLE: maximum temperatures Test voltage (V)...: +3.3V derived from Minicard slot connector of Notebook PC, when temperatures were stable. Temperature rise T of part/at: T( C) Allowed T max ( C) 1. On PCB, near Antenna Ports (between J2 & J6) 2. On PCB, between shielding cover and L32 3. On the bottom of enclosure of Notebook PC, over EUT (*1) (*2) (*3) P Room ambient (T amb ) Page 14 of 17

15 Notes: 1. Maximum operation ambient temperature specified by manufacturer (T ma ) is 35 C. 2. T max of the PCB is to be rated 105 C minimum, thus the allowed maximum temperature (T max ) is 93 C at ambient of 35 C. (Allowed T max ( C) = T max + T amb - T ma = =93). 3. T max of the plastic cover is to be rated 95 C minimum, thus the allowed maximum temperature (T max ) is 83 C at ambient of 35 C. (Allowed T max ( C) = T max + T amb - T ma = =83). Test condition: During the test, EUT was inserted onto a Notebook PC, and ran continuously the Maximum Normal Load (see page 7), with the following conditions: (*1). 11a at Channel 5.22 GHz, rate 6 Mbps, Target power = 17.0; duration was 1 hr, 36 minutes. (*2). 11g at Channel GHz, rate 6Mbps, Target power = 17.0; duration was 1 hr, 32 minutes. (*3). OFDM at Channel 2.4 GHz, rate 6 Mbps, target power =17.0; duration was 1 hr, 19 minutes. Page 15 of 17

16 7. PHOTOS (Top View of EUT) (Bottom View of EUT) Page 16 of 17

17 (EUT was installed inside the Host for testing) (END OF REPORT) Page 17 of 17

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 EN 301 489-17 v1.2.1 TEST REPORT FOR 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 ISSUE DATE: JANUARY 29, 2008 Prepared for BROADCOM CORPORATION 190 MATHILDA

More information

Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD)

Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD) Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD) Note: This guidance document is a translation of official Chinese document which is issued by CQC (China Quality Certification Center) on

More information

Guide to the electrical parameter classifications of IEC 60950 and IEC 62368 safety standards

Guide to the electrical parameter classifications of IEC 60950 and IEC 62368 safety standards Guide to the electrical parameter classifications of IEC 60950 and IEC 62368 safety standards Abstract This Guide is an informative listing of selected terms and definitions found in IEC Glossary entry

More information

Report No: SZESO10060061001 Date: 2010-12-08

Report No: SZESO10060061001 Date: 2010-12-08 Applicant : Shenzhen Gembird Electronics Ltd 2nd Floor, Building B, Shifeng Industry District, Huaning Lu, Dalang Street, Longhua, Shenzhen, China Manufacturer: Same as applicant Test object / Model :

More information

DS 600. A contact free flux gate based current measurement sensor 600A rms

DS 600. A contact free flux gate based current measurement sensor 600A rms DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum

More information

TEST REPORT. Report nº: 13.08.053.199 LABEL Date: 01-10-2013 Laboratório de Ensaios Eléctricos Page nº: 1/11

TEST REPORT. Report nº: 13.08.053.199 LABEL Date: 01-10-2013 Laboratório de Ensaios Eléctricos Page nº: 1/11 Laboratório de Ensaios Eléctricos Page nº: 1/11 TESTING/ELABORATION: Hugo Santos JOB: Laboratory Technician VERIFICATION: Sónia Valério JOB: Laboratory Technician TECHNICAL APPROVAL: João Costa JOB: Technical

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2007-01-31 Page 1 of 1 Report Reference # E137006-A19-CB-1 COVER PAGE FOR TEST REPORT Test Item Description: Model/Type Reference: DIN-Rail Switch Mode Power Supply XT40.KK1-XX and XT40.KK2-XX,

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to

More information

ANSI Watthour Meter Testing & Certification Programs

ANSI Watthour Meter Testing & Certification Programs ANSI Watthour Meter Testing & Certification Programs By Jim Reed Manager, Meter Accuracy Lab and Manasi Bhandiwad Manager, EMC Lab Laboratories, Inc. First in Certification Accreditations and Recognitions

More information

Low Voltage Examination Report Re-Examination of a Money Exchange machine

Low Voltage Examination Report Re-Examination of a Money Exchange machine Low Voltage Examination Report Re-Examination of a Money Exchange machine Reference number Status test report Brand : 11C01263RPT01 : Final : Suzo-Happ Model number : 182-8000 Serial number : 18211080061/182111200006

More information

Low Voltage Examination Report Examination of an Electric isolation monitor. Status test report. : Techneo Electronics. Serial numbers : 1 and 2

Low Voltage Examination Report Examination of an Electric isolation monitor. Status test report. : Techneo Electronics. Serial numbers : 1 and 2 Low Voltage Examination Report Examination of an Electric isolation monitor Reference number Status test report Brand Model number : 09C00090RPT01 : Final : Techneo Electronics : TE-IMD1 Serial numbers

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual. i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

Current Probes. User Manual

Current Probes. User Manual Current Probes User Manual ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained herein shall

More information

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT For SAMBO HI TECH CO., LTD. 616-15, GANSUK4-DONG, NAMDONG-GU, INCHUN 405-810, KOREA Model: LSR700, SCI545HV1EF, SCI545HVEF This Report Concerns: Original

More information

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6 Alarm over IP IRIS Touch Home Installation Manual Version 1.0 ENGLISH Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6 1. Introduction No more bulky batteries, just one sleek unit

More information

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

What are the basic electrical safety issues and remedies in solar photovoltaic installations? What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety Topics Covered Photovoltaic

More information

Optocoupler, Phototransistor Output, with Base Connection

Optocoupler, Phototransistor Output, with Base Connection Optocoupler, Phototransistor Output, with Base Connection FEATURES i794-4 DESCRIPTION This datasheet presents five families of Vishay industry standard single channel phototransistor couplers. These families

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,

More information

T 3000. Substation Maintenance and Commissioning Test Equipment

T 3000. Substation Maintenance and Commissioning Test Equipment T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy

More information

Low Voltage Products. Switches Automatic Transfer Switches

Low Voltage Products. Switches Automatic Transfer Switches Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. High energy prices,

More information

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By the Authority Vested By Part 5 of the United States Code 552(a) and Part 1 of the Code of Regulations 51 the attached document has

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60950-1 Second edition 2005-12 Information technology equipment Safety Part 1: General requirements IEC 2005 Copyright - all rights reserved No part of this publication may be

More information

Risk Analysis Fanless Slim Medical Panel PC, models xxxx-onyx-2121dtyxxxxxxx

Risk Analysis Fanless Slim Medical Panel PC, models xxxx-onyx-2121dtyxxxxxxx Risk Analysis Fanless Slim Medical Panel PC, models xxxx-onyx-2121dtyxxxxxxx Company: Creation Date: 2013-08-22 Abbreviation: Project Number: Project : Version Number: Version : Life Cycle Phase: ONYX-2121DT

More information

FAQs-Main switchboard design criteria

FAQs-Main switchboard design criteria FAQs-Main switchboard design criteria Q: What is the Australian standard for main switchboards? Current Australian standard is AS/NZS 3439.1: 2002 originating from IEC 60439. The new series of standard

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011 Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.

More information

Dielectric Withstand Testing in a Production Environment

Dielectric Withstand Testing in a Production Environment Dielectric Withstand Testing in a Production Environment Performing a routine product safety test should not in itself represent a shock hazard to the operator who is conducting the test, yet anytime you

More information

NEC Class 2 Power Circuits and Power Supplies

NEC Class 2 Power Circuits and Power Supplies NEC Class 2 Power Circuits and Power Supplies Abstract: The NEC (National Electrical Code) is a North American standard, which can be regarded as a law in most of the North American states. Among others,

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-P series I PN = 6, 10, 25 A Ref: HO 6-P, HO 10-P, HO 25-P For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary

More information

10 Multimeter. Users Manual

10 Multimeter. Users Manual 10 Multimeter Users Manual 1991-2001 Fluke Corporation, All rights reserved. Printed in USA All product names are trademarks of their respective companies. 10 MULTIMETER m m Mk SELECT RANGE OFF VDC VAC

More information

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting 12 SOLAR PHOTOVOLTAIC POWER by John Ware IT IS PLANNED for BS 7671:2008 to include a new Section 712 providing additional requirements for safety applicable to solar photovoltaic (pv) power supply systems.

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

08. SEK IDC CONNECTORS

08. SEK IDC CONNECTORS . IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these

More information

A Practical Guide to Dielectric Testing

A Practical Guide to Dielectric Testing Chroma Systems Solutions, Inc. A Practical Guide to Dielectric Testing 19032 Series Electrical Safety Analyzer & 19050 Series Hipot Tester AC/DC/IR/SCAN Keywords: Dielectric tests, insulation resistance

More information

Product Safety Considerations for Insulation Coordination of Low- Voltage Equipment. Scott Aldous, Compliance Engineer

Product Safety Considerations for Insulation Coordination of Low- Voltage Equipment. Scott Aldous, Compliance Engineer Product Safety Considerations for Insulation Coordination of Low- Voltage Equipment Scott Aldous, Compliance Engineer What is Insulation Coordination? From IEC 60664-1, Edition 1.2: So what does that mean

More information

Calculating Creepage and Clearance Early Avoids Design Problems Later Homi Ahmadi

Calculating Creepage and Clearance Early Avoids Design Problems Later Homi Ahmadi Calculating Creepage and Clearance Early Avoids Design Problems Later Homi Ahmadi One of the most common errors uncovered by product safety engineers stems from manufacturers and designers failing to fully

More information

6/14/02 Chapter 14: Use of Electrical Test Equipment 1/20

6/14/02 Chapter 14: Use of Electrical Test Equipment 1/20 USE OF ELECTRICAL TEST EQUIPMENT Test equipment is necessary for determining proper set-up, adjustment, operation, and maintenance of electrical systems and control panels. The following is a general procedure

More information

rigel 288 Electrical Medical Safety Analyser Key Features Applications

rigel 288 Electrical Medical Safety Analyser Key Features Applications rigel 288 Electrical Medical Safety Analyser Key Features Versatile Test in Accordance with the leakage requirements of IEC/EN 60601-1, AAMI and NFPA, IEC 62353 (VDE 0751-1) using separate IEC 60601 and

More information

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820 Test Report Prepared for: Technologic Systems, Inc. Model: TS-8820 Description: Single Board Computer with Analog and Digital Inputs and Outputs, Relays, and RS-232/485 Ports To IEC 61000-6-1 (2005-03)

More information

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02

More information

SURGE PROTECTIVE DEVICES

SURGE PROTECTIVE DEVICES SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood

More information

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

USB-ISO - USB 2.0 compliant, 1000VDC USB Full Speed isolator Users Manual

USB-ISO - USB 2.0 compliant, 1000VDC USB Full Speed isolator Users Manual USB-ISO - USB 2.0 compliant, 1000VDC USB Full Speed isolator Users Manual All boards produced by Olimex are ROHS compliant Rev. D, July 2011 Copyright(c) 2011, OLIMEX Ltd, All rights reserved Page1 INTRODUCTION

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

Grounding Demystified

Grounding Demystified Grounding Demystified 3-1 Importance Of Grounding Techniques 45 40 35 30 25 20 15 10 5 0 Grounding 42% Case 22% Cable 18% Percent Used Filter 12% PCB 6% Grounding 42% Case Shield 22% Cable Shielding 18%

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions

More information

HP UPS R1500 Generation 3

HP UPS R1500 Generation 3 HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications

More information

Actuator-Sensor-Interface

Actuator-Sensor-Interface Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current

More information

1 Form A Solid State Relay

1 Form A Solid State Relay 1 Form A Solid State Relay Vishay Semiconductors DIP i1791- SMD DESCRIPTION Vishay solid state relays (SSRs) are miniature, optically coupled relays with high-voltage MOSFET outputs. The LH1518 relays

More information

Technicaldata General

Technicaldata General Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description

More information

PROTECTION AGAINST ELECTRIC SHOCK by John Ware

PROTECTION AGAINST ELECTRIC SHOCK by John Ware 16 become live under fault conditions. The potential of the metal enclosure is higher than that of the main earthing terminal of the installation (and that of Earth) because of a potential difference created

More information

Everything you need for protection scheme testing

Everything you need for protection scheme testing Power System Simulator for Testing Protection Relays and Schemes Everything you need for protection scheme testing The is the only instrument with the high power, flexibility and software to perform full

More information

AMP CO Plus Insert for Cat. 6 A Applications

AMP CO Plus Insert for Cat. 6 A Applications Product Specification 108-93039 10/Mar/2011 Rev F AMP CO Plus Insert for Cat. 6 A Applications 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP* CO Plus

More information

IEEE802.3poep Study Group Revision of isolation requirements in IEEE802.3 clause 33.

IEEE802.3poep Study Group Revision of isolation requirements in IEEE802.3 clause 33. IEEE802.3poep Study Group Revision of isolation requirements in IEEE802.3 clause 33. San Francisco, July 2005 Arkadiy Peker Powerdsine Arkadiyp@powerdsineusa.com Yair Darshan Powerdsine Yaird@powerdsine.com

More information

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input

More information

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

Verizon NEBS TM Compliance: HVAC Systems NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9808 Issue 1, April 2014

Verizon NEBS TM Compliance: HVAC Systems NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9808 Issue 1, April 2014 Verizon NEBS TM Compliance: HVAC Systems NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9808 Issue 1, April 2014 CHANGE CONTROL RECORD: Version Date Action* Reason for Revision 1 4/14/2014

More information

Model UT713 OPERATING MANUAL

Model UT713 OPERATING MANUAL Model UT713 OPERATING MANUAL TABLE OF CONTENTS TITLE PAGE Introduction Unpacking Inspection Safety Information Turning the Calibrator On Simulating a Thermocouple Measuring a Thermocouple Simulating TC

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration

More information

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Insulation resistance

Insulation resistance The insulation resistance is particularly important for the prevention of damage and injury, and for the reliability of electrical systems and equipment. On the one hand it is basis for the protection

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

Instructions A622 100 Amp AC/DC Current Probe 070-8883-03

Instructions A622 100 Amp AC/DC Current Probe 070-8883-03 Instructions A622 100 Amp AC/DC Current Probe 070-8883-03 Revision A www.tektronix.com 070888303 Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents,

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

5SV Residual Current Protective Devices

5SV Residual Current Protective Devices s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective

More information

Tutorial on Safety Standard Compliance For Hipot Testing

Tutorial on Safety Standard Compliance For Hipot Testing Chroma Systems Solutions, Inc. Tutorial on Safety Standard Compliance For Hipot Testing 19071, 19073 Hipot Testers Keywords: Safety Issues, Electrical Shock, Fire, Hipot (Dielectric Withstand), Leakage

More information

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu, APPROVAL SHEET CUSTOMER ituner CUSTOMER P/N DESCRIPTION EDAC MODEL 12V/6.6A SERIES NO. (E17) EA10953A DATE 2010-06-22 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12 Table of Contents The Basics of Electricity 2 Using a Digital Multimeter 4 IDEAL Digital Multimeters An Introduction The Basics of Digital Multimeters is designed to give you a fundamental knowledge of

More information

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a

More information

Application Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole)

Application Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole) Overcurrentswitch,6A,2p,D-Char,AC Partno. FAZ-D6/2 Articleno. 278777 CatalogNo. FAZ-D6/2 Similar to illustration Deliveryprogramme Basic function Miniature circuit breakers Pole 2 pole Tripping characteristic

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

Optocoupler, Phototransistor Output, High Reliability, 5300 V RMS, Low Input Current

Optocoupler, Phototransistor Output, High Reliability, 5300 V RMS, Low Input Current Optocoupler, Phototransistor Output, High Reliability, 53 V RMS, Low Input Current FEATURES A C 1 2 4 3 C E Operating temperature from -55 C to +11 C Good CTR linearity depending on forward current Isolation

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Electrical Safety Tester Verification

Electrical Safety Tester Verification Ensuring Validity of Regulatory Tests Verification of electrical safety testing equipment is a procedure that is often overlooked by manufacturers. Running test verification is crucial to ensuring that

More information

AC and DC Drive System Installation Information

AC and DC Drive System Installation Information Purpose This document contains the Parker SSD Drives recommendations for installing drive systems. These instructions must be followed for safe and reliable operation. Instructions CODES AND REGULATIONS

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH ENGLISH EMOSAFE EN-100 Product Data Sheet Network Isolators for PCB assembly November 2013 1 GENERAL DESCRIPTION The EMOSAFE EN-100 Network Isolator interrupts all galvanically conducting connections (conductors

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

Agilent 87421A/87422A Power Supply

Agilent 87421A/87422A Power Supply Agilent 87421A/87422A Power Supply Technical Overview Designed specifically for Agilent Technologies microwave system amplifiers Bias cable permits remote placement Compact size for easy system integration

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Achat 115MA full-range speaker. user manual

Achat 115MA full-range speaker. user manual Achat 115MA full-range speaker user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2011-12-17 Page 1 of 19 Report Reference # E146893-V1-S24 Revised: 2013-03-21 UL TEST REPORT AND PROCEDURE Standard: ANSI/AAMI ES 60601-1:2005 (Medical electrical equipment Part 1: General

More information

Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012

Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012 Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012 CHANGE CONTROL RECORD: Version Date Action* Reason for Revision

More information

14. Troubleshooting Guide

14. Troubleshooting Guide 14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include

More information

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data. Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated

More information

LOXONE 12 Channel Amplifier

LOXONE 12 Channel Amplifier LOXONE 12 Channel Amplifier Item no.: 200110 Thank you for purchasing the Loxone Twelve Channel Amplifier. The versatility of the Amplifier makes it the perfect choice for almost every type of custom multi-room

More information

Are you aware. Outline

Are you aware. Outline Electrical Safety of Medical Equipment Hasan Al-Nashash School of Engineering American University of Sharjah (AUS) 1 Are you aware Electrocutions are the 5th leading cause of accidental death in the U.S.

More information

Optocoupler, Phototransistor Output, Dual Channel, SOIC-8 Package

Optocoupler, Phototransistor Output, Dual Channel, SOIC-8 Package ILD25T, ILD26T, ILD27T, ILD211T, ILD213T Optocoupler, Phototransistor Output, Dual Channel, SOIC-8 Package i17925 A1 C2 A3 C4 i17918-2 8C 7E 6C 5E DESCRIPTION The ILD25T, ILD26T, ILD27T, ILD211T, and ILD213T

More information

OZW30. Central Unit SYNERGYR

OZW30. Central Unit SYNERGYR 2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control

More information