1 FCC DoC TEST REPORT REPORT NO.: FD960115L07 MODEL NO.: XO-B2 (Refer to item 3.1 for the more details) RECEIVED: Jan. 12, 2007 TESTED: Feb. 09 ~ Oct. 05, 2007 ISSUED: Oct. 08, 2007 APPLICANT: OLPC ADDRESS: 1 Cambridge Center, Cambridge, Massachusetts, USA ISSUED BY: Advance Data Technology Corporation LAB ADDRESS: No. 47, 14th Ling, Chia Pau Tsuen, Lin Kou Hsiang 244, Taipei Hsien, Taiwan, R.O.C. TEST LOCATION: No. 19, Hwa Ya 2nd Rd., Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This test report consists of 24 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product endorsement by TAF, A2LA or any government agency. The test results in the report only apply to the tested sample. Report No.: FD960115L07 1 Report Format Version 2.0.6

2 Table of Contents 1 CERTIFICATION SUMMARY OF TEST RESULTS MEASUREMENT UNCERTAINTY GENERAL INFORMATION GENERAL DESCRIPTION OF EUT DESCRIPTION OF TEST MODES DESCRIPTION OF SUPPORT UNITS CONFIGURATION OF SYSTEM UNDER TEST TEST TYPES AND RESULTS CONDUCTED EMISSION MEASUREMENT LIMITS OF CONDUCTED EMISSION MEASUREMENT TEST INSTRUMENTS TEST PROCEDURES DEVIATION FROM TEST STANDARD TEST SETUP EUT OPERATING CONDITIONS TEST RESULTS RADIATED EMISSION MEASUREMENT LIMITS OF RADIATED EMISSION MEASUREMENT TEST INSTRUMENTS TEST PROCEDURES DEVIATION FROM TEST STANDARD TEST SETUP EUT OPERATING CONDITIONS TEST RESULTS PHOTOGRAPHS OF THE TEST CONFIGURATION INFORMATION ON THE TESTING LABORATORIES APPENDIX A MODIFICATION RECORDERS FOR ENGINEERING CHANGES TO THE EUT BY THE LAB Report No.: FD960115L07 2 Report Format Version 2.0.6

3 1 CERTIFICATION PRODUCT: Laptop BRAND: OLPC MODEL NO.: XO-B2 (Refer to item 3.1 for the more details) APPLICANT: OLPC TESTED: Feb. 09 ~ Oct. 05, 2007 TEST SAMPLE: ENGINEERING SAMPLE STANDARD: FCC Part 15: 2007, Subpart B, Class B CISPR 22: 1997, Class B ICES-003: 2004, Class B ANSI C63.4: 2003 The above equipment (model: XO-B2) has been tested by Advance Data Technology Corporation, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample s EMC characteristics under the conditions specified in this report. PREPARED BY :, DATE : Oct. 08, 2007 Peggy Chen / Specialist TECHNICAL ACCEPTANCE :, DATE : Oct. 08, 2007 Responsible for EMI Antony Lee / Supervisor APPROVED BY :, DATE : Oct. 08, 2007 David Liu / Senior Engineer Report No.: FD960115L07 3 Report Format Version 2.0.6

4 2 SUMMARY OF TEST RESULTS The EUT has been tested according to the following specifications. EMISSION Standard Test Type Result Remarks FCC Part 15: 2007, Subpart B, Class B CISPR 22: 1997, Class B ICES-003: 2004, Class B Conducted emission test Radiated emission test PASS PASS Meet the requirement of limit. Minimum passing margin is db at MHz. Meet the requirement of limit. Minimum passing margin is db at MHz. Note: The limit for radiated test for MHz was performed according to CISPR 22:1997, which was specified in FCC PART 15 Subpart B (g). Also the limits of ICES-003:2004 and CISPR 22:1997 are same. 2.1 MEASUREMENT UNCERTAINTY Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR : Measurement Frequency Uncertainty Conducted emissions 9kHz ~ 30MHz 2.44 db 30MHz ~ 200MHz 3.39 db Radiated emissions 200MHz ~1000MHz 3.43 db 1GHz ~ 18GHz 2.26 db This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. Report No.: FD960115L07 4 Report Format Version 2.0.6

5 3 GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF EUT PRODUCT MODEL NO. POWER SUPPLY DATA CABLE POWER CORD ACCESSORY DEVICES Laptop XO-B2 (Refer to Note 1 for the more details) 12Vdc from AC adapter NA NA Adapter NOTE: 1. The models are identical as below to each other, except for their model designation due to marketing requirement. Model Name Remark XO-B2 - XO*** * mean - or _ or A~Z or 0~9. 2. The EUT is powered by the following adapter. Brand DELTA ELECTRONICS. INC. Model ADP-15PH A Input Power Vac, 0.6A, 50-60Hz Output Power 12Vdc, 1.25A Power Line 1.8m non-shielded cable with one core 3. The above EUT information was declared by manufacturer and for more detailed features description, please refer to the manufacturer's specifications or User's Manual. Report No.: FD960115L07 5 Report Format Version 2.0.6

6 3.2 DESCRIPTION OF TEST MODES The EUT is designed with AC power supply of V, 50/60Hz. For EMC evaluation, 230Vac/50Hz (for EN 55022), 120Vac/60Hz (for FCC Part 15) had been covered during the pre-test. The worst radiated emission data was founded at 230Vac/50Hz and recorded in the applied test report. 3.3 DESCRIPTION OF SUPPORT UNITS The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests. NO. PRODUCT BRAND MODEL NO. SERIAL NO. FCC ID 1 KEYBOARD DELL SK-8115 MY-OJ FCC DoC Approved 2 MOUSE DELL M056U FCC DoC Approved 3 MOUSE DELL M056U FCC DoC Approved 4 MICROPHONE Labtec LVA7313 NA NA 5 EARPHONE PHILIPS SBC HL125 NA NA 6 WIRELESS AP corega CG-WLBARAG2 NA NA 7 NOTEBOOK DELL PP04X NA FCC DoC Approved NO. SIGNAL CABLE DESCRIPTION OF THE ABOVE SUPPORT UNITS 1 1.8m shielded cable 2 1.8m shielded cable 3 1.8m shielded cable 4 1.8m shielded cable 5 1.8m shielded cable 6 1.8m shielded cable 7 NA NOTE: 1. All power cords of the above support units are non-shielded (1.8m). 2. Item 6~7 acted as communication partners to transfer data. 3. Item 6~7 were provided by client. Report No.: FD960115L07 6 Report Format Version 2.0.6

7 3.4 CONFIGURATION OF SYSTEM UNDER TEST EUT (Power from AC adapter) Test Table Microphone Earphone Keyboard Mouse Mouse RJ45 UTP Cable Notebook Wireless AP *Kept in a remote area Report No.: FD960115L07 7 Report Format Version 2.0.6

8 4 TEST TYPES AND RESULTS 4.1 CONDUCTED EMISSION MEASUREMENT LIMITS OF CONDUCTED EMISSION MEASUREMENT TEST STANDARD: FCC Part 15: 2007, Subpart B (Section: ) CISPR 22: 1997 (section 5) ICES-003: 2004 (Class A: section 5.2) (Class B: section 5.3) Frequency (MHz) Class A (dbuv) Class B (dbuv) Quasi-peak Average Quasi-peak Average NOTE: 1. The lower limit shall apply at the transition frequencies. 2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50 MHz. 3. All emanations from a class A/B digital device or system, including any network of conductors and apparatus connected thereto, shall not exceed the level of field strengths specified above TEST INSTRUMENTS DESCRIPTION & MANUFACTURER MODEL NO. SERIAL NO. CALIBRATED UNTIL Test Receiver ROHDE & SCHWARZ ESCS Dec. 07, 2007 RF signal cable Woken 5D-FB Cable-HYC01-01 Jan. 06, 2008 LISN ROHDE & SCHWARZ ESH3-Z Feb. 13, 2008 LISN ROHDE & SCHWARZ NNBL May 07, 2008 Software ADT ADT_Cond_V3 NA NA NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable to NML/ROC and NIST/USA. 2. The test was performed in HwaYa Shielded Room The VCCI Site Registration No. is C Report No.: FD960115L07 8 Report Format Version 2.0.6

9 4.1.3 TEST PROCEDURES The basic test procedure was in accordance with ANSI C63.4: 2003 (section 7), CISPR 22 (section 9) and ICES-003:2004 (section 4). a. The EUT was placed 0.4 meters from the conducting wall of the shielded room with EUT being connected to the power mains through a line impedance stabilization network (LISN). Other support units were connected to the power mains through another LISN. The two LISNs provide 50 ohm/ 50uH of coupling impedance for the measuring instrument. b. Both lines of the power mains connected to the EUT were checked for maximum conducted interference. c. The frequency range from 150kHz to 30MHz was searched. Emission levels under Limit - 20dB was not recorded DEVIATION FROM TEST STANDARD No deviation TEST SETUP V ertical Ground Reference Plane Test Receiver 40cm EUT LISN 80cm Horizontal Ground Reference Plane Note: 1.Support units were connected to second LISN. 2.Both of LISNs (AM N) are 80 cm from EUT and at least 80 cm from other units and other metal planes For the actual test configuration, please refer to the related item Photographs of the Test Configuration. Report No.: FD960115L07 9 Report Format Version 2.0.6

10 4.1.6 EUT OPERATING CONDITIONS a. Placed the EUT on the testing table. b. The EUT ran a test program to enable EUT under transmission/receiving condition continuously at specific channel frequency. c. Prepared a notebook and wireless AP outside of testing area to act as a communication partner. d. Sent data to EUT by command "PING" from the communication partner. Report No.: FD960115L07 10 Report Format Version 2.0.6

11 4.1.7 TEST RESULTS INPUT POWER (SYSTEM) ENVIRONMENTAL CONDITIONS TESTED BY 120 Vac, 60 Hz 24 deg. C, 67% RH, 1006 hpa Ban Hsieh 6dB BANDWIDTH 9 khz PHASE Line 1 Emission Corr. Reading Value Limit Margin Freq. Level No Factor [db (uv)] [db (uv)] [db (uv)] (db) [MHz] (db) Q.P. AV. Q.P. AV. Q.P. AV. Q.P. AV REMARKS: 1. Q.P. and AV. are abbreviations of quasi-peak and average individually. 2. "-": The Quasi-peak reading value also meets average limit and measurement with the average detector is unnecessary. 3. The emission levels of other frequencies were very low against the limit. 4. Margin value = Emission level - Limit value 5. Correction factor = Insertion loss + Cable loss 6. Emission Level = Correction Factor + Reading Value. Report No.: FD960115L07 11 Report Format Version 2.0.6

12 INPUT POWER (SYSTEM) ENVIRONMENTAL CONDITIONS TESTED BY 120 Vac, 60 Hz 24 deg. C, 67% RH, 1006 hpa Ban Hsieh 6dB BANDWIDTH 9 khz PHASE Line 2 Emission Corr. Reading Value Limit Margin Freq. Level No Factor [db (uv)] [db (uv)] [db (uv)] (db) [MHz] (db) Q.P. AV. Q.P. AV. Q.P. AV. Q.P. AV REMARKS: 1. Q.P. and AV. are abbreviations of quasi-peak and average individually. 2. "-": The Quasi-peak reading value also meets average limit and measurement with the average detector is unnecessary. 3. The emission levels of other frequencies were very low against the limit. 4. Margin value = Emission level - Limit value 5. Correction factor = Insertion loss + Cable loss 6. Emission Level = Correction Factor + Reading Value. Report No.: FD960115L07 12 Report Format Version 2.0.6

13 4.2 RADIATED EMISSION MEASUREMENT LIMITS OF RADIATED EMISSION MEASUREMENT TEST STANDARD: FCC Part 15: 2007, Subpart B (Section: ) CISPR 22: 1997 (section 6) ICES-003: 2004 (Class A: section 5.4) (Class B: section 5.5) Frequency (MHz) Class A (at 10m) Class B (at 10m) Quasi-peak (dbuv/m) Quasi-peak (dbuv/m) NOTE: The limit for radiated test was performed according to CISPR 22:1997, which was specified in FCC PART 15B (g). Also the limits of ICES-003:2004 and CISPR 22:1997 are same. Frequency (MHz) Class A (at 3m) Class B (at 3m) Peak (dbuv/m) Average (dbuv/m) Peak (dbuv/m) Average (dbuv/m) Above NOTE: 1. The lower limit shall apply at the transition frequencies. 2. Emission level (dbuv/m) = 20 log Emission level (uv/m). 3. All emanations from a class A/B digital device or system, including any network of conductors and apparatus connected thereto, shall not exceed the level of field strengths specified above. FREQUENCY RANGE OF RADIATED MEASUREMENT (For unintentional radiators) Highest frequency generated or Upper frequency of measurement used in the Range (MHz) device or on which the device operates or tunes (MHz) Below th harmonic of the highest frequency or Above GHz, whichever is lower Report No.: FD960115L07 13 Report Format Version 2.0.6

14 4.2.2 TEST INSTRUMENTS DESCRIPTION & MANUFACTURER Test Receiver ROHDE & SCHWARZ Test Receiver ROHDE & SCHWARZ Spectrum Analyzer Agilent BILOG Antenna SCHWARZBECK BILOG Antenna SCHWARZBECK HORN Antenna EMCO Preamplifier Agilent Preamplifier Agilent Preamplifier Agilent RF signal cable Woken RF signal cable Woken RF signal cable HUBER+SUHNER RF signal cable HUBER+SUHNER Software ADT Antenna Tower HD Deisel GmbH Antenna Tower HD Deisel GmbH Turn Table HD Deisel GmbH Controller HD Deisel GmbH MODEL NO. SERIAL NO. CALIBRATED UNTIL ESIB Dec. 07, 2007 ESIB May 07, EC 4208A00662 Dec. 25, 2007 VULB Nov. 28, 2007 VULB Nov. 28, Jul. 22, D 2944A10637 Dec. 10, D 2944A10636 Dec. 10, B 3008A01959 Dec. 17, D-FB Cable-Hych1-01 Oct. 15, D-FB Cable-Hych1-02 Oct. 15, 2007 SUCOFLEX /4 Nov. 14, 2007 SUCOFLEX /4 Nov. 14, 2007 ADT_Radiated_V7 NA NA MA NA MA NA DS NA HD NA NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable to NML/ROC and NIST/USA. 2. The test was performed in HwaYa Chamber The VCCI Site Registration No. is R The IC Site Registration No. is IC3789B-1. Report No.: FD960115L07 14 Report Format Version 2.0.6

15 4.2.3 TEST PROCEDURES The basic test procedure was in accordance with ANSI C (section 8), CISPR 22 (section 10) and ICES-003: 2004 (section 4). a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 10 meters semi-anechoic chamber. The table was rotated 360 degrees to determine the position of the highest radiation. b. The EUT was set 10 / 3 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower. c. The antenna is a broadband antenna, and its height is varied from one meter to four meters above the ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement. d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to find the maximum reading. e. The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum hold mode when the test frequency is below 1 GHz. NOTE: The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120 khz for quasi-peak detection (QP) at frequency below 1 GHz DEVIATION FROM TEST STANDARD No deviation. Report No.: FD960115L07 15 Report Format Version 2.0.6

16 4.2.5 TEST SETUP EUT& Support Units 10m / 3m Ant. Tower 1-4m Variable Turn Table 80cm Ground Plane Test Receiver For the actual test configuration, please refer to the related item Photographs of the Test Configuration EUT OPERATING CONDITIONS Same as Report No.: FD960115L07 16 Report Format Version 2.0.6

17 4.2.7 TEST RESULTS ENVIRONMENTAL CONDITIONS 23 deg. C, 71% RH, 991 hpa FREQUENCY RANGE MHz DETECTOR FUNCTION & BANDWIDTH Quasi-Peak, 120 khz TESTED BY Skys Huang No. Freq. (MHz) ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 10 M Emission Level (dbuv/m) Limit (dbuv/m) Margin (db) Antenna Height (m) Table Angle (Degree) Raw Value (dbuv) Correction Factor (db/m) QP H QP H QP H QP H QP H QP H QP H QP H QP H QP H QP H QP H REMARKS: 1. Emission level(dbuv/m)=raw Value(dBuV) + Correction Factor(dB/m) 2. Correction Factor(dB/m) = Antenna Factor (db/m) + Cable Factor (db) 3. The other emission levels were very low against the limit. 4. Margin value = Emission level Limit value. Report No.: FD960115L07 17 Report Format Version 2.0.6

18 ENVIRONMENTAL CONDITIONS 23 deg. C, 71% RH, 991 hpa FREQUENCY RANGE MHz DETECTOR FUNCTION & BANDWIDTH Quasi-Peak, 120 khz TESTED BY Skys Huang No. Freq. (MHz) ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 10 M Emission Level (dbuv/m) Limit (dbuv/m) Margin (db) Antenna Height (m) Table Angle (Degree) Raw Value (dbuv) Correction Factor (db/m) QP V QP V QP V QP V QP V QP V QP V QP V QP V QP V QP V QP V QP V QP V QP V QP V QP V QP V QP V QP V REMARKS: 1. Emission level(dbuv/m)=raw Value(dBuV) + Correction Factor(dB/m) 2. Correction Factor(dB/m) = Antenna Factor (db/m) + Cable Factor (db) 3. The other emission levels were very low against the limit. 4. Margin value = Emission level Limit value. Report No.: FD960115L07 18 Report Format Version 2.0.6

19 ENVIRONMENTAL CONDITIONS 23 deg. C, 68% RH, 1006 hpa FREQUENCY RANGE 1-7 GHz DETECTOR FUNCTION & BANDWIDTH Peak/Average, 1 MHz TESTED BY Kevin Chen No. Freq. (MHz) ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M Emission Level (dbuv/m) Limit (dbuv/m) Margin (db) Antenna Height (m) Table Angle (Degree) Raw Value (dbuv) Correction Factor (db/m) PK H AV H PK H AV H PK H AV H PK H AV H PK H AV H REMARKS: 1. Emission level(dbuv/m)=raw Value(dBuV) + Correction Factor(dB/m) 2. Correction Factor(dB/m) = Antenna Factor (db/m) + Cable Factor (db) 3. The other emission levels were very low against the limit. 4. Margin value = Emission level Limit value. Report No.: FD960115L07 19 Report Format Version 2.0.6

20 ENVIRONMENTAL CONDITIONS 23 deg. C, 68% RH, 1006 hpa FREQUENCY RANGE 1-7 GHz DETECTOR FUNCTION & BANDWIDTH Peak/Average, 1 MHz TESTED BY Kevin Chen No. Freq. (MHz) ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M Emission Level (dbuv/m) Limit (dbuv/m) Margin (db) Antenna Height (m) Table Angle (Degree) Raw Value (dbuv) Correction Factor (db/m) PK V AV V PK V AV V PK V AV V PK V AV V PK V AV V REMARKS: 1. Emission level(dbuv/m)=raw Value(dBuV) + Correction Factor(dB/m) 2. Correction Factor(dB/m) = Antenna Factor (db/m) + Cable Factor (db) 3. The other emission levels were very low against the limit. 4. Margin value = Emission level Limit value. Report No.: FD960115L07 20 Report Format Version 2.0.6

21 5 PHOTOGRAPHS OF THE TEST CONFIGURATION Conducted Emission Test Report No.: FD960115L07 21 Report Format Version 2.0.6

22 Radiated Emission Test Report No.: FD960115L07 22 Report Format Version 2.0.6

23 6 INFORMATION ON THE TESTING LABORATORIES We, ADT Corp., were founded in 1988 to provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are accredited and approved by the following approval agencies according to ISO/IEC 17025: USA Germany Japan Norway Canada R.O.C. Netherlands Singapore Russia FCC, UL, A2LA TUV Rheinland VCCI NEMKO INDUSTRY CANADA, CSA TAF, BSMI, NCC Telefication GOST-ASIA(MOU) CERTIS(MOU) Copies of accreditation certificates of our laboratories obtained from approval agencies can be downloaded from our web site: If you have any comments, please feel free to contact us at the following: Linko EMC/RF Lab Tel: Fax: Hsin Chu EMC/RF Lab Tel: Fax: Hwa Ya EMC/RF/Safety/Telecom Lab Tel: Fax: Web Site: The address and road map of all our labs can be found in our web site also. Report No.: FD960115L07 23 Report Format Version 2.0.6

24 7 APPENDIX A MODIFICATION RECORDERS FOR ENGINEERING CHANGES TO THE EUT BY THE LAB No any modifications are made to the EUT by the lab during the test. Report No.: FD960115L07 24 Report Format Version 2.0.6

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT For SAMBO HI TECH CO., LTD. 616-15, GANSUK4-DONG, NAMDONG-GU, INCHUN 405-810, KOREA Model: LSR700, SCI545HV1EF, SCI545HVEF This Report Concerns: Original

More information

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module Engineering Test Report No. 37802-02 Rev. A Measurement of RF Emissions from a Final Coat Electronics Corrosion Module For : Canadian Auto Preservation, Inc. 390 Bradwick Drive Concord, Ontario CANADA

More information

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS A TESTING

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS A TESTING TESTING CERT #803.01, 803.02, 803.05, 803.06 MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS A TESTING DATE OF

More information

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 EN 301 489-17 v1.2.1 TEST REPORT FOR 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 ISSUE DATE: JANUARY 29, 2008 Prepared for BROADCOM CORPORATION 190 MATHILDA

More information

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820 Test Report Prepared for: Technologic Systems, Inc. Model: TS-8820 Description: Single Board Computer with Analog and Digital Inputs and Outputs, Relays, and RS-232/485 Ports To IEC 61000-6-1 (2005-03)

More information

FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT

FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT For AeroComm, Inc. 10981 Eicher Drive Lenexa, KS 66219 2003-05-22 This Report Concerns: Original Report Equipment Type: 900MHz Transceiver Test Engineer:

More information

CE EMC TEST REPORT (EN 50155 & EN 50121-3-2)

CE EMC TEST REPORT (EN 50155 & EN 50121-3-2) CE EMC TEST REPORT (EN 50155 & EN 50121-3-2) REPORT NO.: CE141111C02-1 TEST MODEL: SPC-2845 SERIES MODEL: Vecow SPC Series, SPC-2145, SPC-2845-W4, SPC-2845X, SPC-2845R, SPC-2845D, SPC-XXXXXXXXXX ("X" can

More information

TEST REPORT. CONCLUSION: The submitted sample was found to COMPLY with the test requirement

TEST REPORT. CONCLUSION: The submitted sample was found to COMPLY with the test requirement TEST REPORT Applicant Address Shenzhen Gembird Electronics Ltd. 5F, Building B, Shi-Feng Industrial Zone, Hua-Ning Rd., Xin-Wei Village, Da-Lang Street, Long-Hua, Bao-An Area, Shenzhen 518109, Guangdong

More information

Test result: SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD. ISO/IEC17025Accredited Lab. Report No: FCC 1106180 File reference No: 2011-07-18

Test result: SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD. ISO/IEC17025Accredited Lab. Report No: FCC 1106180 File reference No: 2011-07-18 Report No: FCC 1106180 File reference No: 2011-07-18 ISO/IEC17025Accredited Lab. Applicant: FUJIAN NAN AN BAOFENG ELECTRONICS CO., LTD Product: Model No: Trademark: Two Way Radio UV-3R BAOFENG Test Standards:

More information

Report Of. Shielding Effectiveness Test For. SafeSleeve Radiation Shielding Technology. Test Date(s): June 07 June 09, 2015

Report Of. Shielding Effectiveness Test For. SafeSleeve Radiation Shielding Technology. Test Date(s): June 07 June 09, 2015 Report Of Shielding Effectiveness Test For SafeSleeve Radiation Shielding Technology Test Date(s): June 07 June 09, 2015 Issue Date: June 10, 2015 UST Project No: 15-0137 Total Number of Pages Contained

More information

RADIO TEST REPORT. EN 300 440-2 SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range. DAkkS - Registration number : D-PL-12092-01-01

RADIO TEST REPORT. EN 300 440-2 SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range. DAkkS - Registration number : D-PL-12092-01-01 RADIO TEST REPORT SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range Report Reference No.... : G0M-1206-2043-TEU440G-V01 Testing Laboratory... : Eurofins Product Service GmbH Address...

More information

Radio Frequency Exposure Test Report

Radio Frequency Exposure Test Report Radio Frequency Exposure EN 62311 January 2008 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0Hz 300GHz) (IEC 62311:2007, modified)

More information

RAPPORTO DI PROVA / TEST REPORT

RAPPORTO DI PROVA / TEST REPORT RAPPORTO DI PROVA / TEST REPORT Rif./Ref.No. FCCTR_130738-0 Data / Date: 17/09/2013 Pagine / Pages : 15 Scopo delle prove /Test object : Richiedente / Applicant : Persona di riferimento / Applicant s referee

More information

Electromagnetic Compatibility Test Report. DC DC umodule Regulator LTM4613

Electromagnetic Compatibility Test Report. DC DC umodule Regulator LTM4613 Report No.: 0000091428 31160742.001 Page 1 of 36 Electromagnetic Compatibility Test Report Prepared in accordance with EN 55022: 2006, +A1: 2007 On DC DC umodule Regulator LTM4613 For Linear Technology

More information

Electromagnetic Compatibility Test Report Test results of Floww equipment

Electromagnetic Compatibility Test Report Test results of Floww equipment Electromagnetic Compatibility Test Report Test results of Floww equipment Reference number Status test report Brand Model number : 10C00357RPT01.doc : Final : Floww : mobilefloww screenfloww pocketfloww

More information

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SND6011RP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT Shenzhen BST Technology Co., Ltd. SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT Prepared For : Product Name: Model : Prepared By : SHENZHEN GEMBIRD ELECTRONICS LTD 5th Floor, Building B, Shifeng Industry

More information

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec.

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec. EMC STANDARDS The EMC standards that a particular electronic product must meet depend on the product application (commercial or military) and the country in which the product is to be used. These EMC regulatory

More information

EMC TEST REPORT For. Webcam. Model Number: CAM67U

EMC TEST REPORT For. Webcam. Model Number: CAM67U EMC TEST REPORT For Webcam Model Number: CAM67U Prepared for : Gembird Europe B.V. Wittevrouwen 56, 1358CD Almere, The Netherlands. Phone: +31-36-5211588 Prepared By : Shenzhen Meihua Electronic Technology

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment Brand Name /Trade Mark Type designation /model Applicant Network Camera SAMSUNG SND-5083P SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SNO-6011RP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

FCC RF Exposure Report

FCC RF Exposure Report FCC RF Exposure Report FCC ID Equipment Model No. Brand Name Applicant : SQGBT900 : Bluetooth Dual Mode UART AT featuring smartbasic : BT900-SA, BT900-SC (please refer to 1.1.1 for more details.) : Laird

More information

For the following information

For the following information For the following information Product : Motherboard Model Number : M5A78L-M/USB3 Brand : ASUS Ref. File No.: C1M1104201 Applicant : ASUSTEK Computer Inc. Manufacturer #1 : MainTek Computer (Suzhou) Co.,

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: PTZ CAMERA SAMSUNG SCP2371HP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD FROM RFI GLOBAL SERVICES LTD Partial Test of: BTM411 To: EN 300 328 V1.7.1 (2006-10) Test Report Serial No: RFI/RPT1/RP76018JD01A This Test Report Is Issued Under The Authority Of Brian Watson, Operations

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: PTZ CAMERA SAMSUNG SNP-5300P SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

AN003. Evaluation of Anechoic Chambers For EMC Measurements Using A CNE. Overview. CNE III 9kHz to 2GHz Conducted and radiated output

AN003. Evaluation of Anechoic Chambers For EMC Measurements Using A CNE. Overview. CNE III 9kHz to 2GHz Conducted and radiated output Evaluation of Anechoic Chambers For EMC Measurements Using A CNE Overview Anechoic chambers are used for EMC testing primarily for radiated emissions (RE) and radiated immunity (RI) in the frequency range

More information

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd.

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd. www.ecmg-global.com EMC TEST REPORT On Model Name: DL-P40 Computer Control System Model Number: Release 3.0 Hardware and Software Brand Name: Dorman Long Technology Ltd. Trade Mark: DLT Prepared for Dorman

More information

MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2

MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2 MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2 EN55024 (1998), EN61000-3-2 (2001), EN61000-3-3 (1995 W/A1: 98), EN55022 (1998) CLASS A, CISPR 22 (1997) CLASS A & FCC PART 15 SUBPART

More information

CERTIFICATE. Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03. MGate MB318n(-T) (n=0~9,a~z)

CERTIFICATE. Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03. MGate MB318n(-T) (n=0~9,a~z) CERTIFICATE Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03 This is to certify that the following designated product Product Trade name Model Number : 1 Port Device Server : Moxa : NPort 5150(-T),

More information

TEST REPORT EN 55014-2 (1997) +A1 (2001)

TEST REPORT EN 55014-2 (1997) +A1 (2001) Page 1 of 23 TEST REPORT EN 55014-2 (1997) +A1 (2001) Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus Part 2: Immunity Report Reference No....

More information

EMI TEST REPORT. Product Name. Notebook Personal Computer. Model A770;A790. Applied by:

EMI TEST REPORT. Product Name. Notebook Personal Computer. Model A770;A790. Applied by: EN55022 / CISPR 22 / AS/NZS CISPR 22 Class B EMI TEST REPORT of Product Name Notebook Personal Computer Model A770;A790 Applied by: MITAC Technology Corporation 4F, No.1, R&D Road 2, Hsinchu Science-Based

More information

CE Test Report. : Microchip Technology Inc. 2355 West Chandler Blvd., Chandler, Arizona 85224-6199, USA

CE Test Report. : Microchip Technology Inc. 2355 West Chandler Blvd., Chandler, Arizona 85224-6199, USA CE Test Report Equipment : IEEE 802.11b/g Wireless LAN module Brand Name : MICROCHIP Model No. : MRF24WG0MA/MB Standard : EN 300 328 V1.8.1 (2012-06) Operating Band : 2400 MHz 2483.5 MHz Applicant Manufacturer

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SNP-6200RHP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

Regulatory requirements - USA

Regulatory requirements - USA Regulatory requirements - USA FCC CFR 47 Part 2 & 15 Radiospectrum and EMF Test on qualified laboratory Test methods different from EU Certification required TCB or FCC Grant Regulatory EMC requirements

More information

FCC Part 15C Compliance Test Report

FCC Part 15C Compliance Test Report Test Report no.: Cph_FCC_732_5.doc Date of Report: 14-8-27 Number of pages: 42 Customer s Contact person: Ole Soerensen Testing laboratory: Customer: Nokia Corporation FCC listing no.: IC recognition no.:

More information

Low-cost EMI Pre-compliance Testing Using a Spectrum Analyzer

Low-cost EMI Pre-compliance Testing Using a Spectrum Analyzer Low-cost EMI Pre-compliance Testing Using a Spectrum Analyzer Application Note EMI regulations are in place throughout the world to provide improved reliability and safety for users of electrical and electronic

More information

AN1200.04. Application Note: FCC Regulations for ISM Band Devices: 902-928 MHz. FCC Regulations for ISM Band Devices: 902-928 MHz

AN1200.04. Application Note: FCC Regulations for ISM Band Devices: 902-928 MHz. FCC Regulations for ISM Band Devices: 902-928 MHz AN1200.04 Application Note: FCC Regulations for ISM Band Devices: Copyright Semtech 2006 1 of 15 www.semtech.com 1 Table of Contents 1 Table of Contents...2 1.1 Index of Figures...2 1.2 Index of Tables...2

More information

ELECTROMAGNETIC COMPATIBILITY TEST. Report reference N R-255 EMC 2010

ELECTROMAGNETIC COMPATIBILITY TEST. Report reference N R-255 EMC 2010 ELECTROMAGNETIC COMPATIBILITY TEST Report reference N R-255 EMC 2010 Constructor. Address Reference person. C LUCE S.r.l. Via Marmolada 5/11 20060 Truccazzano (MI) Italy ---- Product....... Model......

More information

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20 EMC TEST REPORT For Shenzhen Homelux Security Equipment Co., Ltd Auto Dialer Model No.: HX-GD20 Prepared for : Shenzhen Homelux Security Equipment Co., Ltd Address : 4 th Floor, Building 5, Jiademaluan

More information

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. 588 West Jindu Road,Songjiang District,Shanghai,China Telephone: +86 (0) 21 6191 5666 Fax: +86 (0) 21 6191 5678 ee.shanghai@sgs.com Page: 1 of 23 1 Cover Page Application No.: Applicant: Manufacturer:

More information

Applications in EMC testing. Outline. Antennas for EMC Testing. Terminology

Applications in EMC testing. Outline. Antennas for EMC Testing. Terminology Antennas for EMC Testing Zhong Chen ETS-Lindgren 1301 Arrow Point Drive Cedar Park, TX 78613 Zhong.Chen@ets-lindgren.com Outline EMC Terms and Definitions Typical EMC Antennas Calibration of EMC Antennas

More information

Test Report #: 1981-3 Date: April 8, 2005

Test Report #: 1981-3 Date: April 8, 2005 Test Report #: 1981-3 Date: April 8, 2005 CERTIFICATE #2316.01 Issued To: Bill Burks American Power Conversion 85 Rangeway Road North Billerica, MA 01862 USA 978-670-2440 Product Name/Description Model

More information

Design and Certification of ASH Radio Systems for Japan

Design and Certification of ASH Radio Systems for Japan Design and Certification of ASH Radio Systems for Japan RFM s second-generation ASH radio hybrids are being used in a wide variety of applications in Japan, operating under the Japanese BIJAKU radio regulations.

More information

FCC Test Report. FCC Part 22, 24 / RSS 132, 133 FOR: GSM Cellular Telephone with Bluetooth and WiFi. Model #: A1203

FCC Test Report. FCC Part 22, 24 / RSS 132, 133 FOR: GSM Cellular Telephone with Bluetooth and WiFi. Model #: A1203 FCC Test Report FCC Part 22, 24 / RSS 132, 133 FOR: GSM Cellular Telephone with Bluetooth and WiFi Model #: A1203 Apple Inc. 1 Infinite Loop Mail Stop26A Cupertino, California 95014 U.S.A FCC ID: BCGA1203

More information

CE Test Report. : BL600 Series Bluetooth Low Energy Module

CE Test Report. : BL600 Series Bluetooth Low Energy Module CE Test Report Equipment Brand Name Model No. : BL600 Series Bluetooth Low Energy Module : Laird Technologies : BL600-SA, BL600-SC, BL600-ST Additional Model No. : BL620-SA, BL620-SC, BL620-ST Standard

More information

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise

More information

TEST REPORT Rapporto di prova EMC N 060406. Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio

TEST REPORT Rapporto di prova EMC N 060406. Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio TEST REPORT Rapporto di prova EMC N 060406 EUT: Organic Carbon Analyzer Analiuzzatore Carbonio Organico Model: TOCMETER Serial N : TM602 Client: TRE-ESSE s.r.l. Cliente Piazzale Europa 8 16036 Recco (GE),

More information

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS Page 1 UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS By Henry Ott Consultants Livingston, NJ 07039 (973) 992-1793 www.hottconsultants.com hott@ieee.org Page 2 THE BASIC

More information

Report No. 091028R-RFCEP02V01. Test Report. MS-6633, VS12489, NetOn AP1900. Transmitter Module. MSI / MS-6894

Report No. 091028R-RFCEP02V01. Test Report. MS-6633, VS12489, NetOn AP1900. Transmitter Module. MSI / MS-6894 Test Report Product Name All in one PC Model No. Transmitter Module. MSI / MS-6894 MS-6633, VS12489, NetOn AP1900 Applicant Address MICRO-STAR INT L Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien,

More information

RF Exposure Evaluation Report

RF Exposure Evaluation Report RF Exposure Evaluation Report APPLICANT EQUIPMENT BRAND NAME MODEL NAME FCC ID FILING TYPE : TomTom International BV : GPS Navigation System : TomTom : 4CR51 : S4L4CR51 : Certification STANDARD : OET Bulletin

More information

EMC TEST REPORT. Page: 1 of 38. Reference No.: WT08010091-S-E

EMC TEST REPORT. Page: 1 of 38. Reference No.: WT08010091-S-E Page: 1 of 38 EMC TEST REPORT Reference No. Applicant Address : WT08010091-S-E : Gembird Electronics Ltd. : Room 1709 A, News Building, #2 Shennan Zhong Lu, Shenzhen, China Equipment Under Test (EUT) :

More information

Partial GSM TEST - REPORT

Partial GSM TEST - REPORT EUROFINS PRODUCT SERVICE GMBH Partial GSM TEST - REPORT EN 301 511 GSM/GPRS/GPS tracking unit FOX-LT-IP Test report no.: G0M20904-2307-T-51 Eurofins Product Service GmbH Storkower Str. 38c, 15526 Reichenwalde,

More information

Application Note AN-00125

Application Note AN-00125 Considerations for Operation within the 260 470MHz Band Introduction This application note is designed to give the reader a basic understanding of the legal and technical considerations for operation of

More information

Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J113-41 test set up, using measured current in NEC and simple TX equations.

Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J113-41 test set up, using measured current in NEC and simple TX equations. Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J113-41 test set up, using measured current in NEC and simple TX equations. D. A. Weston RE02Tx.rep 14-6-2004 NARTE Certified EMC

More information

CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN14040316E-E01 EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD.

CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN14040316E-E01 EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD. EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD. CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN14040316E-E01 Phone: +86-755-83585700 3A, F1.6, Tianfa Building, Tian an Cyber Park, Fax: +86-755-83585701 Futian

More information

Item tested : Tecsonic DAB518. Type of equipment : DAB & FM radio. Client : Post- og teletilsynet

Item tested : Tecsonic DAB518. Type of equipment : DAB & FM radio. Client : Post- og teletilsynet Test report no. : 156924-4 Item tested : Tecsonic DAB518 Type of equipment : DAB & FM radio Client : Post- og teletilsynet Nemko Comlab is granted accreditation by Norwegian Accreditation under registration

More information

Electromagnetic Compatibility and International Regulatory Approvals

Electromagnetic Compatibility and International Regulatory Approvals Electromagnetic Compatibility and International Regulatory Approvals Most countries have now implemented strict regulations regarding Electromagnetic Compatibility (EMC) for electronic devices. This paper

More information

Uncertainty evaluations in EMC measurements

Uncertainty evaluations in EMC measurements Uncertainty evaluations in EMC measurements Carlo Carobbi Dipartimento di Elettronica e Telecomunicazioni Università degli Studi di Firenze Politecnico di Milano - 20 Feb. 2009 1 Non - reproducibility

More information

Broadband over Power Line (BPL) Test Procedures and Equipment Authorization

Broadband over Power Line (BPL) Test Procedures and Equipment Authorization Broadband over Power Line (BPL) Test Procedures and Equipment Authorization Andy Leimer Equipment Authorization Branch Federal Communications Commission Office of Engineering and Technology Laboratory

More information

CE EMC Test Report. : Texas Instruments Incorporated : WiFi and Bluetooth Evaluation Board

CE EMC Test Report. : Texas Instruments Incorporated : WiFi and Bluetooth Evaluation Board CE EMC Test Report APPLICANT EQUIPMENT BRAND NAME MODEL NAME : Texas Instruments Incorporated : WiFi and Bluetooth Evaluation Board : Texas Instruments : WL1835MODCOM8B STANDARD : ETSI EN 301 489-1 V1.9.2

More information

Electrified Door Hardware Why Planning for FCC Certification is Key to Success in the Door Hardware Industry

Electrified Door Hardware Why Planning for FCC Certification is Key to Success in the Door Hardware Industry Why Planning for FCC Certification is Key to Success in the Door Hardware Industry For more information about Intertek s testing and certification capabilities, please contact Intertek at 1-800-WORLDLAB,

More information

DSA800 Series Spectrum Analyzer

DSA800 Series Spectrum Analyzer DSA800 Series Spectrum Analyzer Configuration Guide This guide is used to help users to configure DSA800 series spectrum analyzer according to their requirements. You can get an overall understanding of

More information

R&S ESL EMI Test Receiver Compact, cost-effective measuring receiver

R&S ESL EMI Test Receiver Compact, cost-effective measuring receiver R&S ESL EMI Test Receiver Compact, cost-effective measuring receiver Test & Measurement Product Brochure 01.00 R&S ESL EMI Test Receiver At a glance The R&S ESL EMI test receiver combines two instruments

More information

Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B)

Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B) Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B) 1. Description and Specifications Contents 1.1 Description 1.2 1.2 Specifications 1.3 1.3 Tested parameters in production

More information

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem The Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem (DPC3010) provides DOCSIS broadband service providers with a cost-effective solution for delivering high-speed

More information

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy Application Note RF & Microwave Spectrum Analyzers Table of Contents 3 3 4 4 5 7 8 8 13 13 14 16 16 Introduction Absolute versus relative

More information

The EMI-Receiver according to CISPR 16-1-1

The EMI-Receiver according to CISPR 16-1-1 Author: Dipl. -Ing. Dieter Schwarzbeck Schwarzbeck Mess-Elektronik An der Klinge 29 D-69250 Schönau / Germany Tel.: +49 6228 1001 Fax.:+49 6228 1003 support@schwarzbeck.de www.schwarzbeck.de Requirements

More information

AM Radio Field Strength Measurements with Confidence November 2004

AM Radio Field Strength Measurements with Confidence November 2004 AM Radio Field Strength Measurements with Confidence November 2004 Understanding the AM Broadcast signal The AM Broadcast service in the United States and many other countries is implemented in 10 khz

More information

Tuning a Monopole Antenna Using a Network Analyzer

Tuning a Monopole Antenna Using a Network Analyzer 11/21/11 Tuning a Monopole Antenna Using a Network Analyzer Chris Leonard Executive Summary: When designing a monopole antenna it is important to know at which frequency the antenna will be operating at.

More information

COUPLING / DECOUPLING NETWORK (CDN) FOR UNSCREENED BALANCED PAIRS

COUPLING / DECOUPLING NETWORK (CDN) FOR UNSCREENED BALANCED PAIRS IEC / EN 61000-4-6 specifies the design and performance of a range of coupling / decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Teseq

More information

5.8GHz Audio/Video Sender

5.8GHz Audio/Video Sender 5.8GHz Audio/Video Sender RF-Link / Araneus USA Inc. 44845 Industrial Dr. Fremont, CA. 94538 U.S.A. Tel: +1-510-4135885~5886 Fax: +1-510-6515995 URL: http://www.rflinkusa.com Design and specification subject

More information

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz Test & Measurement Data Sheet 02.00 R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz R&S R-Line Compact Test Chamber At a glance The R-Line

More information

EMC Test for Compliance with EU EMC Directive 2004/108/EU

EMC Test for Compliance with EU EMC Directive 2004/108/EU EMC Test for Compliance with EU EMC Directive 2004/108/EU Partial Test 12-12-2012 Standards Description EN 55022:2011 Information technology equipment - Radio disturbance characteristics - Limits and methods

More information

R&S ZNC Vector Network Analyzer Specifications

R&S ZNC Vector Network Analyzer Specifications ZNC3_dat-sw_en_5214-5610-22_v0300_cover.indd 1 Data Sheet 03.00 Test & Measurement R&S ZNC Vector Network Analyzer Specifications 04.09.2012 13:39:47 CONTENTS Definitions... 3 Measurement range... 4 Measurement

More information

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION 1 SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION By Lannes S. Purnell FLUKE CORPORATION 2 This paper shows how standard signal generators can be used as leveled sine wave sources for calibrating oscilloscopes.

More information

Product Specifications

Product Specifications Cisco Model EPR2320 EuroDOCSIS 2.0 Residential Gateway with Wireless Access Point The Cisco Model EPR2320 EuroDOCSIS 2.0 Residential Gateway (EPR2320) combines a cable modem, router, and wireless access

More information

BioStation Mifare OC(BSM-OC) NONE. Receipt Date 21-Feb-08 Receipt Number. Issued Date 18-Mar-08 Tested Date

BioStation Mifare OC(BSM-OC) NONE. Receipt Date 21-Feb-08 Receipt Number. Issued Date 18-Mar-08 Tested Date Test Report for CE Report Number Applicant ESTCE0803-003 Company Name Address Product type Suprema Inc. 16F Parkview Office Tower, Jeongja-dong, Bundang-gu,Seongnam, Gyeonggi, 463-863 Korea FINGERPRINT

More information

Report No. 106262R-RFCEP76V01-A. Test Report. Model No. MS-AE12, AE2420 3D, MS-AE31 3D, MS-AE31, AE2420. Date of Receipt June 15, 2010

Report No. 106262R-RFCEP76V01-A. Test Report. Model No. MS-AE12, AE2420 3D, MS-AE31 3D, MS-AE31, AE2420. Date of Receipt June 15, 2010 Test Report Product Name All in one PC Model No. MS-AE12, AE2420 3D, MS-AE31 3D, MS-AE31, AE2420 Applicant MICRO-STAR INT'L Co., LTD. Address No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C.

More information

TCB Workshop. Unlicensed National Information Infrastructure Devices (U-NII)/Dynamic Frequency Selection (DFS)

TCB Workshop. Unlicensed National Information Infrastructure Devices (U-NII)/Dynamic Frequency Selection (DFS) 1 TCB Workshop Unlicensed National Information Infrastructure Devices (U-NII)/Dynamic Frequency Selection (DFS) Andrew Leimer Office of Engineering and Technology/Equipment Authorization Branch FCC Laboratory

More information

Radiated Emission and Susceptibility

Radiated Emission and Susceptibility Radiated Emission and Susceptibility Tzong-Lin Wu, Ph.D. EMC Lab Department of Electrical Engineering National Taiwan University Differential-Mode v.s. Common-mode Currents 1 Differential-Mode v.s. Common-mode

More information

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0. Receiver AC-RX2/CS RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. Pin-out 38.1 3 Component Side 1 2 3 7 11 13 14 15

More information

Variant Model No. The equipment under test has found to be compliant with the applied standards. (Refer to the attached test result for more detail.

Variant Model No. The equipment under test has found to be compliant with the applied standards. (Refer to the attached test result for more detail. EMC TEST REPORT Project No. LBE091881 Revision No. NONE Name of organization Samsung Electronics Co., Ltd. Applicant Address 416 Maetan 3-Dong,Yeongtong-Gu,Suwon-Si, Gyeonggi-Do, 443-742 Korea Date of

More information

Installation Instructions. Wireless Adapter/Repeater. Introduction. 30-3001-887 Rev C

Installation Instructions. Wireless Adapter/Repeater. Introduction. 30-3001-887 Rev C /Repeater Installation Instructions 30-3001-887 Rev C Workstation Ethernet bcx Controller Repeater Repeater Introduction Schneider Electric has designed a device that allows Andover Continuum controllers

More information

Pre-Compliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions

Pre-Compliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions PreCompliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions D. Schneider 1*, S. Tenbohlen 1, W. Köhler 1 1 Institute of Power Transmission and

More information

RF EXPOSURE LIMITS AND TESTING REQUIREMENTS

RF EXPOSURE LIMITS AND TESTING REQUIREMENTS RF EXPOSURE LIMITS AND TESTING REQUIREMENTS Jay Moulton Vice President March 12, 2013 1 OVERVIEW Specific Absorption Rate (SAR) and Maximum Permissible Exposure (MPE) Standards and Limits Evaluation Methods

More information

Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Solid State Energy Meter

Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Solid State Energy Meter Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Model: Solid State Energy Meter Prepared for: Analog Devices, Inc. 804 Woburn Street Wilmington, MA 01887 Date of

More information

USB 3.0* Radio Frequency Interference Impact on 2.4 GHz Wireless Devices

USB 3.0* Radio Frequency Interference Impact on 2.4 GHz Wireless Devices USB 3.0* Radio Frequency Interference Impact on 2.4 GHz Wireless Devices White Paper April 2012 Document: 327216-001 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE,

More information

Agilent E5100A Network Analyzer

Agilent E5100A Network Analyzer Agilent E5100A Network Analyzer Data Sheet These specifications are the performance standards or limits against which the instrument is tested. When shipped from the factory, the E5100A meets the specifications

More information

Correlation between OATS, Fully Anechoic Room and GTEM Radiated Emissions

Correlation between OATS, Fully Anechoic Room and GTEM Radiated Emissions Correlation between OATS, Fully Anechoic Room and GTEM Radiated Emissions Stephen Clay Introduction: Just a few words about myself. My name is Steve Clay and I work for Nokia Mobile Phones, and it is my

More information

R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements

R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements on telecommunications ports Test & Measurement Data Sheet 01.00 R&S ENY81-CA6 Coupling Network At a glance The R&S ENY81-CA6

More information

R&S ZVA Vector Network Analyzer Specifications

R&S ZVA Vector Network Analyzer Specifications www.atecorp.com 8-44-ATEC (2832) R&S ZVA Vector Network Analyzer Specifications ZVA_dat-sw_en_523-568-22_v_cover.indd Data Sheet. E stablished 98 Advanced Test Equipment Rentals Test & Measurement 4.5.22

More information

USER MANUAL. Kramer Electronics, Ltd. Models:

USER MANUAL. Kramer Electronics, Ltd. Models: Kramer Electronics, Ltd. USER MANUAL Models: VP-200N, 1:2 High Resolution XGA DA VP-300N, 1:3 High Resolution XGA DA VP-400N, 1:4 High Resolution XGA DA Contents Contents 1 Introduction 1 2 Getting Started

More information

R&S ZNBT8 Vector Network Analyzer Specifications

R&S ZNBT8 Vector Network Analyzer Specifications ZNBT8_dat-sw_en_3606-9727-22_v0200_cover.indd 1 Data Sheet 02.00 Test & Measurement R&S ZNBT8 Vector Network Analyzer Specifications 20.05.2014 08:39:42 CONTENTS Definitions... 3 Measurement range... 4

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

Keysight Technologies N9320B RF Spectrum Analyzer

Keysight Technologies N9320B RF Spectrum Analyzer Keysight Technologies N9320B RF Spectrum Analyzer 9 khz to 3.0 GHz Data Sheet Definitions and Conditions The spectrum analyzer will meet its specifications when: It is within its calibration cycle It has

More information

APSYN420A/B Specification 1.24. 0.65-20.0 GHz Low Phase Noise Synthesizer

APSYN420A/B Specification 1.24. 0.65-20.0 GHz Low Phase Noise Synthesizer APSYN420A/B Specification 1.24 0.65-20.0 GHz Low Phase Noise Synthesizer 1 Introduction The APSYN420 is a wideband low phase-noise synthesizer operating from 0.65 to 20 GHz. The nominal output power is

More information

Workbench EMC Measurements by Henry W. Ott Henry Ott Consultants www.hottconsultants.com

Workbench EMC Measurements by Henry W. Ott Henry Ott Consultants www.hottconsultants.com Workbench EMC Measurements by Henry W. Ott Henry Ott Consultants www.hottconsultants.com Workbench EMC measurements are simple, inexpensive precompliance tests that a product designer can perform early

More information

Keysight N9320B RF Spectrum Analyzer

Keysight N9320B RF Spectrum Analyzer Keysight N9320B RF Spectrum Analyzer 9 khz to 3.0 GHz Data Sheet 02 Keysight N9320B RF Spectrum Analyzer - Data Sheet Definitions and Conditions Specifications describe the performance of parameters covered

More information