Install NEMA 4X enclosure for the Sievers * InnovOx Online TOC Analyzer

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Install NEMA 4X enclosure for the Sievers * InnovOx Online TOC Analyzer"

Transcription

1 6060 Spine Road Boulder, CO USA USA Europe Worldwide Install NEMA 4X enclosure for the Sievers * InnovOx Online TOC Analyzer Introduction Purpose: To install the NEMA 4x enclosure for the Sievers InnovOx Online TOC Analyzer. Scope: This procedure describes how to install the NEMA 4X Enclosure and how to install the 2 or 5- stream InnovOx Online TOC Analyzer into the NEMA 4X Enclosure. The Enclosure is designed for use in indoor, non-hazardous locations. The Enclosure protects the InnovOx Online TOC Analyzer against falling dirt, dust, splashing and hose-directed water, and corrosion. Safety: The NEMA 4X Enclosure weighs approximately 150 lb without the Analyzer installed in it. Lift the Enclosure only using equipment designed to safely support that weight. Specifications: The NEMA 4X accessory consists of a corrosion-resistant enclosure fitted with access panels, a vortex cooler assembly, and NEMA 4X-rated pass-through fittings for fluidic and electrical connections to the Analyzer. The following drawings show the locations of the pass-throughs, vortex cooler, and related hardware. Specifications for the Enclosure are provided: Dimensions (H x W x D): Weight: Enclosure material: Ambient temperature limits: Mounting: Environment: 53.2 in. x 39.4 in. x 25.3 in. (135 cm x 100 cm x 64.3 cm) Without Analyzer or vortex cooler: 150 lb (68.0 kg) With Analyzer and vortex cooler: 235 lb (107 kg) Fiberglass-reinforced polyester F (10 to 40 C) Wall mounted, ten 5/16 diameter fasteners Indoors, non-hazardous, not in direct sunlight Vortex cooler compressed air: Oil-free, up to 25 SCFM (0.012 m 3 s -1 ) 90 to 100 psig (620 to 689 kpa) Max. Temperature: 110 F (43 C) Vortex cooler filter element: Air line for vortex cooler: in. (5 μm), non-coalescing If length < 30 ft: 3/8 schedule 40 pipe If length 30 ft: 1/2 schedule 40 pipe * Sievers is a trademark of General Electric Company and may be registered in one or more countries. GE Analytical Instruments, Inc. 2010J Page 1 of 24 DIN Rev. B

2 Control (Signal) Check Standard Sample # 1 thru #5 Air to Filter Panel: #1 thru #5 Level Sensors: Check Standard Dilution Water Oxidizer Acid Reagents: Dilution Water Acid Oxidizer Left Side View GE Analytical Instruments, Inc. 2010J Page 2 of 24 DIN Rev.B

3 Filter Housing Compressed Air for Vortex Cooler AC Inlet, ½ NPT Vortex Cooler Carrier Gas Right-Side View GE Analytical Instruments, Inc. 2010J Page 3 of 24 DIN Rev.B

4 Drain for Analyzer Enclosure Drains for NEMA 4X Enclosure Waste 2X Sample #1 thru #5 Drains. From sample cup Bottom View Materials NEMA 4X Enclosure NEMA 4X Accessory Kit: (2) Mount Brackets (clamps) (6) 5/16-18 Nuts (mount clamps to instrument) (4) x 2 L Screws (secure instrument to back panel) (4) ½ Conduit Elbows (2) 8 Flex Conduit Pieces (1) 360 of 3/8 O.D. Clear PVC Tube (drains) 3/8 NPT Tube Kit for Vortex Cooler Air Inlet Includes 2 straight pipe couplings, 1 90deg. Elbow, & 2 hose clamps. (2) Large Drain Fittings and Nuts (For ¾ O.D. Tubing) (8) Smaller Drains Fittings and Nuts (for 3/8 O.D. Tubing) (15) ¼ Drain Plugs (For sample & drain ports) GE Analytical Instruments, Inc. 2010J Page 4 of 24 DIN Rev.B

5 (5) 5/32 Drain Plugs (For filter Panel Ports) (1) Vortex Cooler with instructions and accessories (Cold Air Duct Tubing & Muffler) Items provided by user: Tools: Channel-Lock Pliers, Straight-Slot Screwdriver, Adjustable Wrench, Portable Drill and Drill Bits, Tape Measure Temporary platform for the Enclosure that is capable of safely supporting 150 lb. Hardware for mounting the Enclosure on a wall. The hardware should be selected based on sitespecific circumstances, but it must accept a 5/16 diameter fastener. Ten fasteners are recommended; in total, the mounting hardware must be able to support four times the weight of the Enclosure and Analyzer (i.e., 940 lb). Compressed air line with 3/8 NPT Male fitting for connection to filter housing Carrier gas line, 1/4 OD polyethylene or polypropylene tubing. Oil-free compressed air having a pressure from 90 to 100 psig and a temperature no greater than 110 F (43 C). The Vortex cooler requires up to 25 SCFM of compressed air. Power and signal lines in grounded metal conduit. See the InnovOx Online TOC Analyzer Operation and Maintenance Manual for details. Sample lines and drain for excess sample and Analyzer waste. See the InnovOx Online TOC Analyzer Operation and Maintenance Manual for details. Procedures A. Select a location for the NEMA 4X Enclosure and the Analyzer. B. Unpack the NEMA 4X Enclosure and prepare for installation. C. Mount the NEMA 4X Enclosure. D. Install Additional Enclosure Equipment. E. Install the InnovOx 2 or 5 Stream TOC Analyzer into the NEMA 4X Enclosure. F. Connect AC Power and Control Signals. G. Install Vortex Cooler H. Install Fail-Safe Level Sensors if so equipped. I. Install Remaining Fluidic Connections J. Finish Installation GE Analytical Instruments, Inc. 2010J Page 5 of 24 DIN Rev.B

6 A. Select a Location for the NEMA 4X Enclosure and the Analyzer 1. Place the NEMA 4X Enclosure in a non-hazardous location indoors, away from direct sunlight and exposure to extreme temperatures. The temperature must not be less than 50 F (10 C) or greater than 104 F (40 C). 2. A drain or other receptacle must be nearby to receive excess sample and acidic wastewater produced by the Analyzer. 3. The location must provide space for the Enclosure and the clearance around the Enclosure, as shown in the figures below. GE Analytical Instruments, Inc. 2010J Page 6 of 24 DIN Rev.B

7 GE Analytical Instruments, Inc. 2010J Page 7 of 24 DIN Rev.B

8 B. Unpack the NEMA 4X Enclosure and Prepare for Installation 1. Remove the NEMA 4X enclosure from its packaging. Check for damage. The enclosure will have most of the passthroughs already installed. 2. Place the NEMA 4X Enclosure on the platform that is capable of safely supporting 150 lb. This provides room for attachment of mounting brackets to the bottom of the Enclosure. (See Steps 3 and 4.) Platform GE Analytical Instruments, Inc. 2010J Page 8 of 24 DIN Rev.B

9 3. Install the 5 large stainless steel brackets, which are included in the accessory kit. One is already installed over the left side cover. The brackets slide into the enclosure between the 2 small marks on the back lip of the enclosure. Install 2 on the right side, 1 on the left side, and 2 on the bottom. 4. Secure the brackets using the plastic clips provided. The clips slide over the bracket and snap into place, keeping the brackets from slipping out of the Enclosure lip. GE Analytical Instruments, Inc. 2010J Page 9 of 24 DIN Rev.B

10 C. Mount the NEMA 4X Enclosure 1. For easier installation (optional), remove Enclosure door by pulling upper and lower pins (8 total) on hinges as far as allowed. 2. Mark the wall for location of the mounting hardware per the figure. GE Analytical Instruments, Inc. 2010J Page 10 of 24 DIN Rev.B

11 3. Use 5/16 diameter mounting hardware to affix the Enclosure to the wall. All 6 brackets must be used. The fasteners must be capable of supporting four times the weight of the Enclosure and Analyzer (i.e., 940 lbs). 4. This picture is for reference only. The application shown is in ½ drywall with appropriate fasteners. 5. The bottom brackets are attached using the center hole and a 5/16 diameter fastener. Bottom brackets are on center. Use appropriate anchors for wall type with a 5/16 diameter fastener. GE Analytical Instruments, Inc. 2010J Page 11 of 24 DIN Rev.B

12 D. Install Additional Enclosure Equipment 1. Install the 10 NEMA 4X pass-throughs that fit into the bottom of the Enclosure. All 10 pass-throughs are in the accessory kit. An interior view of the bottom of the Enclosure is provided at the right, showing the pass-throughs installed. Any pass-through that will not have a tube must have a plug installed. Waste 2x Sample 1 thru 5 Drain. From sample block Analyzer Enclosure Drain Drain for NEMA 4X Enclosure 2. You may find it convenient to install the 3/8 OD clear tubing through the 2 or 5 NEMA 4X pass-throughs for Samples #1 thru #5 (depending on model) before installing those pass-throughs in the Enclosure. 3. If you plan to install the two tubes for the cabinet drains to the fittings for the NEMA 4X Enclosure, make sure that the tube does not extend above the fitting. See the figure on the right. 4. If you do not plan to add the two tubes to the cabinet drain fittings for the NEMA 4X Enclosure, insert 1/4 diameter plugs into the fittings. Ensure drain tubing does not extend above fitting GE Analytical Instruments, Inc. 2010J Page 12 of 24 DIN Rev.B

13 5. Install the 2 large (for 3/4 OD drain tubing) fittings in the position marked Waste in the figure shown in Step 1. E. Install the InnovOx 2-Stream TOC Analyzer into the NEMA 4X Enclosure. 1. Before installing the InnovOx 2 or 5 Stream TOC Analyzer, refer to the Operations and Maintenance manual (or the Quick-Start Guide), as well as the Installation Drawing, for proper installation procedure. GE Analytical Instruments, Inc. 2010J Page 13 of 24 DIN Rev.B

14 2. Attach one mounting bracket on the top of the Analyzer, with the bracket facing to the rear. The bracket is fastened using three 5/16-18 flange nuts provided in the accessories kit. 3. Attach a second mounting bracket on the bottom of the Analyzer, with the bracket facing the rear. This bracket also is fastened using three 5/16-18 flange nuts. GE Analytical Instruments, Inc. 2010J Page 14 of 24 DIN Rev.B

15 4. The brackets installed in Step 3 fit over the metal bars located on the rear panel inside the NEMA 4X Enclosure. Metal Bars 5. Insert the Analyzer into the Enclosure. Then lift the Analyzer onto the metal bars. Use the access panels on the right and/or left sides of the Enclosure to aid in lifting the Analyzer. AT LEAST TWO PERSONS ARE REQUIRED TO MOVE THE ANALYZER. GE Analytical Instruments, Inc. 2010J Page 15 of 24 DIN Rev.B

16 F. Connect AC Power and Control Signals. ALL ELECTRICAL INSTALLATION SHOULD BE PERFORMED BY A CERTIFIED ELECTRICIAN 1. On right side, run hard conduit to the AC Inlet connector (1/2 NPT fitting) on the right side of the NEMA 4X Enclosure. AC In 2. Install the 8 piece of conduit, and 2 90 o elbows, inside the NEMA 4X Enclosure to the Analyzer. 3. Repeat Steps 1-2 on the left side of the Enclosure to provide conduit for the Control connections. Input/Output cables will be connected to the Analyzer through this conduit. For details on making electrical connections to the Analyzer, refer to the Operations and Maintenance Manual for the InnovOx Online TOC Analyzer. Use the access panels on the sides and top of the Enclosure for access to the Analyzer s top panel and the electrical interfaces inside it. G. Install Vortex Cooler GE Analytical Instruments, Inc. 2010J Page 16 of 24 DIN Rev.B

17 1. Unpack the Vortex Cooler and refer to its Operations and Safety Instructions. Vortex Cooler 2. Attach the air inlet fittings to the Vortex Cooler as shown, using Teflon tape on all joints. Take 3/8 NPT pipe fitting with attached 90 o elbow, and screw it into fitting on Vortex Cooler. 3. Attach the 5-micron filter housing onto the elbow. Filter Housing 4. Remove spanner nut from Vortex Cooler. GE Analytical Instruments, Inc. 2010J Page 17 of 24 DIN Rev.B

18 5. Place Vortex Cooler in large hole on upper-right side of NEMA 4X Enclosure. Ensure that Vortex Cooler is oriented with the air inlet on the top. Air Inlet 6. Replace and tighten spanner nut until it is finger-tight, plus ¼ turn. 7. The properly installed Vortex Cooler assembly is displayed in the pictures on the right. Warning: When Operating, the sheet metal on the Vortex Cooler unit is hot. Do not touch. GE Analytical Instruments, Inc. 2010J Page 18 of 24 DIN Rev.B

19 8. Install muffler by adhering it to the interior of the Enclosure on the right side, approximately 8-12 below the Vortex Cooler. GE Analytical Instruments, Inc. 2010J Page 19 of 24 DIN Rev.B

20 9. Install Cold Air Duct tubing and hose clamp by pushing onto threaded fitting of Vortex Cooler. Tighten hose clamp. 10. Push the other end of the tube onto the muffler barb. 11. Push the remaining Cold Air Duct tubing onto the second muffler barb. Hose clamp GE Analytical Instruments, Inc. 2010J Page 20 of 24 DIN Rev.B

21 12. This second tube can be arranged one of two ways to distribute cold air inside the Enclosure: The tube can be left unplugged, so that the cold air exits the tube entirely at the end opposite from the muffler. If this approach is selected, ensure that the end of the tube is not pointed directly at the Analyzer. The tube can be made into a diffuser by drilling at least sixteen 1/8 diameter holes in it. Then the end of the tube is plugged as shown at the right. 13. Use the provided adhesive clips to mount the tubing to the walls of the enclosure. GE Analytical Instruments, Inc. 2010J Page 21 of 24 DIN Rev.B

22 H. Install Fail-Safe Level Sensors 1. For Analyzers fitted with the Fail-Safe Accessory: Install Level Sensor cables by pushing cables through pass-throughs on the left side of the Enclosure and the left side of the Analyzer. 2. Inside the Analyzer, attach the grounding wire on each cable to the grounding screw provided. 3. Attach float cables to proper connectors inside the Analyzer as follows: Check standard: LS1 connector Acid: LS2 connector Oxidizer: LS3 connector Dilution water: LS4 connector GE Analytical Instruments, Inc. 2010J Page 22 of 24 DIN Rev.B

23 4. Secure the 4 cables to both cable straps inside the Analyzer, and then snap straps close. I. Install Remaining Fluidic Connections 1. Refer to the Sievers InnovOx Online TOC Operation and Maintenance Manual to determine the correct fluidic connections for your Analyzer and application. 2. Extend the tube for each fluidic connection required for your Analyzer through the corresponding pass-through on the NEMA 4X Enclosure. The locations of these pass-throughs are shown in the figures on pages 2 and 3. GE Analytical Instruments, Inc. 2010J Page 23 of 24 DIN Rev.B

24 3. Plug any unused pass-through with plugs supplied in the accessories kit. For example, if the Analyzer will only monitor one sample stream, plug the sample #2 thru #5 inlets on the left side of the Analyzer and the Sample #2 thru #5 drains on the bottom. 4. If the Analyzer is not fitted with 2 to 5 Filter Panels, plug the unused Air-to-Filter Panel pass-through(s) of the left side of the Enclosure. 5. If the Analyzer is not fitted with the Fail- Safe Accessory, plug the pass-throughs for the Level Sensors on the left side of the Enclosure. J. Finish Installation 1. On the exterior of the Enclosure, tighten each pass-through around the tube (or cable) that is inserted in it. Finger-tighten the outer nut around the tube/cable. 2. Plug any pass-through on the Enclosure that does not have a tube or cable in it. 3. Place all of the drain tubes into their appropriate drains or receptacles. 4. Remove plastic around the NEMA 4X Enclosure. 5. Dispose of removed materials according to local regulations. 6. Complete the installation procedures in the Sievers InnovOx Online TOC Analyzer Operation and Maintenance Manual. 7. If a Filter Panel is used with the Analyzer, complete the relevant installation procedures. Refer to the GE InnovOx Filter Panel Operation and Maintenance Manual. 8. Turn on the compressed air to the Vortex Cooler. 9. Follow the Start-Up procedure in the Sievers InnovOx Online TOC Analyzer Operation and Maintenance Manual. 10. Close and secure the front door and all access panels on the NEMA 4X Enclosure. GE Analytical Instruments, Inc. 2010J Page 24 of 24 DIN Rev.B

Replacing the Gas/Liquid Separator, NDIR Filter, Waste Block and Reactor Valve Seals in Sievers InnovOx TOC Analyzers

Replacing the Gas/Liquid Separator, NDIR Filter, Waste Block and Reactor Valve Seals in Sievers InnovOx TOC Analyzers 6060 Spine Road Boulder, CO 80301 USA USA 1 800 255 6964 Europe 0161 864 6800 Worldwide 303 444 2009 Replacing the Gas/Liquid Separator, NDIR Filter, Waste Block and Reactor Valve Seals in Sievers InnovOx

More information

Replacing the Flow Switch on Sievers 900 and 5310 C Series TOC Analyzers

Replacing the Flow Switch on Sievers 900 and 5310 C Series TOC Analyzers 6060 Spine Road Boulder, CO 80301 USA T 303 444 2009 F 303 444 9543 Replacing the Flow Switch on Sievers 900 and 5310 C Series TOC Analyzers 1. Purpose: To replace the flow switch in Sievers* 900 and 5310

More information

Replacing the Gas Manifold in All Sievers InnovOx TOC Analyzers

Replacing the Gas Manifold in All Sievers InnovOx TOC Analyzers 6060 Spine Road Boulder, CO 80301 USA USA 1 800 255 6964 Europe 0161 864 6800 Worldwide 303 444 2009 Introduction Replacing the Gas Manifold in All Sievers InnovOx TOC Analyzers Purpose: Scope: Safety:

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

Butler Faucet Kit. Installation Guide. Zuvo Water Purator 1. UNPACKING AND INSPECTION. Butler Faucet Assembly

Butler Faucet Kit. Installation Guide. Zuvo Water Purator 1. UNPACKING AND INSPECTION. Butler Faucet Assembly Prior to installing the Butler Faucet, locate and record the serial number on your Zuvo Water Purator. This serial number appears on the lower back of the device. Zuvo Water Purator Butler Faucet Kit Installation

More information

Installation Instructions

Installation Instructions GE Consumer & Industrial Appliances Installation Instructions Junction Box Cover Within this user bag, you will find a junction box cover and a #10 hex head screw used to attach the junction box cover

More information

Installation Instructions

Installation Instructions Installation Instructions For Use with PXPV230, PXPV265, PXPD230, and PXPD265 models Attention! - Please read these instructions completely before attempting installation. Always unplug the power supply

More information

REPLACEMENT PROCEDURE FOR REFRIGERATOR COOLING SYSTEMS

REPLACEMENT PROCEDURE FOR REFRIGERATOR COOLING SYSTEMS LITERATURE NUMBER MPD 14073 REPLACEMENT PROCEDURE FOR REFRIGERATOR COOLING SYSTEMS Rev 4 - Effective 7/16/2014. Replacement Refrigerator Effective Dates For refrigerators with date codes of Nov 15, 2012

More information

Drain Hose. Electrical Cable or Power Cord. Strain Relief. Air Gap. GPF65 Side-Mount Bracket Kit. Flat Blade Screwdriver.

Drain Hose. Electrical Cable or Power Cord. Strain Relief. Air Gap. GPF65 Side-Mount Bracket Kit. Flat Blade Screwdriver. CAUTION: MATERIALS YOU WILL NEED: Installation Instructions If you have questions, call 800.GE.CARES (800.432.2737) or visit our website at: www.ge.com PARTS SUPPLIED FOR INSTALLATION: Two Phillips head

More information

CPU Printed Circuit Board Replacement Instructions Sievers UPW Boron Analyzer

CPU Printed Circuit Board Replacement Instructions Sievers UPW Boron Analyzer 6060 Spine Road Boulder, CO 80301 USA T 303 444 2009 F 303 444 9543 CPU Printed Circuit Board Replacement Instructions Sievers UPW Boron Analyzer 1. Purpose 2. Scope To remove and replace the central processing

More information

Solenoid Valve Assembly Replacement Instructions Sievers UPW Boron Analyzer

Solenoid Valve Assembly Replacement Instructions Sievers UPW Boron Analyzer 6060 Spine Road Boulder, CO 80301 USA T 303 444 2009 F 303 444 9543 Solenoid Valve Assembly Replacement Instructions Sievers UPW Boron Analyzer 1. Purpose 2. Scope To remove and replace the solenoid valve

More information

XL PREMIUM OIL COOLER KIT

XL PREMIUM OIL COOLER KIT -J05 REV. 0-0-0 XL PREMIUM OIL COOLER KIT GENERAL Kit Number 0008 Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com (English

More information

Installation Instructions

Installation Instructions Installation Instructions One-Piece Deep Wall Sleeve For Use with Packaged Terminal Units Please read these instructions completely before attempting installation. NOTE: Ensure that the unit is only installed

More information

Y Parts Included: Canvas Office Landscape, Ethospace, AO Sliding Door Storage Unit Assembly Installation and Disassembly for Recycling Instruction

Y Parts Included: Canvas Office Landscape, Ethospace, AO Sliding Door Storage Unit Assembly Installation and Disassembly for Recycling Instruction Y Parts Included: Canvas Office Landscape, Ethospace, AO Sliding Door Storage Unit Assembly Installation and Disassembly for Recycling Instruction A End Panel Assemblies Short B End Panel Assemblies Tall

More information

Installation Instructions for Wall & Frame Mounted Overhead Cabinets

Installation Instructions for Wall & Frame Mounted Overhead Cabinets Installation Instructions for Wall & Frame Mounted Overhead Cabinets CAUTION MAKE SURE THE WALL MEETS THE LOAD CAPACITY REQUIREMENTS FOR THE OVERHEAD CABINET BEING INSTALLED. REFER TO LOCAL BUILDING CODES

More information

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors Installation Manual Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors SW602206 Rev B Table of Contents Chapter 1: Safety Warning... 3 Chapter 2: Kit Contents... 4 Included in Kit...

More information

Installation Instructions

Installation Instructions Installation Instructions Built-In Dishwasher If you have questions, call 1-800-4-MY-HOME (1-800-469-4663) or visit our website at: www.sears.com BEFORE YOU BEGIN Read these instructions completely and

More information

TABLE OF CONTENTS. General Warnings Installation Programming System Start-Up Frequently Asked Questions...

TABLE OF CONTENTS. General Warnings Installation Programming System Start-Up Frequently Asked Questions... Service Manual Table of Contents TABLE OF CONTENTS Page General Warnings... 3 Installation... 5 Programming... 7 System Start-Up... 8 Frequently Asked Questions... 10 Drawings and Part Numbers... 11 Front

More information

79-93 HEAT. Hellion Power Systems 79-93 HeaT Kit Instructions

79-93 HEAT. Hellion Power Systems 79-93 HeaT Kit Instructions 79-93 HEAT Hellion Power Systems 79-93 HeaT Kit Instructions Hellion Power Systems 86-93 Turbocharger System Instalation Instructions Oil drain First steps 1. If you plan on replacing fuel pump, make sure

More information

Rack installation instructions

Rack installation instructions Rack installation instructions Review the documentation that comes with the rack cabinet for safety and cabling information. Before you install the server in a rack cabinet, review the following guidelines:

More information

Installation Instructions 4508 4508S

Installation Instructions 4508 4508S SYMPHONY Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect

More information

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8

More information

Cooktop Low-Profile Ventilation Hoods

Cooktop Low-Profile Ventilation Hoods INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............

More information

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic

More information

INSTALLATION AND SERVICE MANUAL

INSTALLATION AND SERVICE MANUAL CI8100 IMI Wilshire, Inc. IMI WILSHIRE, INC. COUNTER INTELLIGENCE BEVERAGE SYSTEM CI8100 INSTALLATION AND SERVICE MANUAL 1993 IMI Wilshire, Inc. TABLE OF CONTENTS CI8100 IMI Wilshire, Inc. SECTION I CI8100

More information

F OR A BOVEGROUND POOLS

F OR A BOVEGROUND POOLS TM F OR A BOVEGROUND POOLS INSTALLATION AND OPERATION MANUAL How Solar Pool Heating Works Why SunHeater TM Works Best Using your pool pump, water is automatically pumped through the solar collector. The

More information

Guide for Modified Assembly: Lightning McQueen. By: Collin Patterson, University of Delaware. Materials and Tools:

Guide for Modified Assembly: Lightning McQueen. By: Collin Patterson, University of Delaware. Materials and Tools: Guide for Modified Assembly: Lightning McQueen By: Collin Patterson, University of Delaware Materials and Tools: PVC o 40 inches of 1 in diameter PVC o 25 inches of ¾ in PVC o 4 x 1 in elbows o 2 x ¾ in

More information

NEMA 4X Enclosure User Guide

NEMA 4X Enclosure User Guide NEMA 4X Enclosure User Guide Anatel Corporation 2200 Central Avenue Boulder, Colorado 80301 U.S.A. Voice: Fax: Support Hot Line: E-mail: Website: (303) 442-5533 (800) 373-0531 (303) 447-8365 1-877-4 ANATEL

More information

SSB9000 Series. SSB Module Switch Box with Barriers. Connection Technology Center, Inc Rae Boulevard Victor, NY (585)

SSB9000 Series. SSB Module Switch Box with Barriers. Connection Technology Center, Inc Rae Boulevard Victor, NY (585) SSB9000 Series SSB Module Switch Box with Barriers M N X10052, REV A 4/2/2012 1 C O N T E N T S SECTION 1: OVERVIEW... 4 Introduction... 4 Description... 4 SSB9000 Series Model Selection... 4 Specifications...

More information

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The

More information

430 Power/Electronics Replacement

430 Power/Electronics Replacement Replacing the main board WARNING Before proceeding, turn off the main power switch and unplug the power cord. Caution Make sure you are properly grounded with an ESD strap before continuing. The main printed

More information

Fresenius Medical Care North America Service Bulletin

Fresenius Medical Care North America Service Bulletin Fresenius Medical Care North America Service Bulletin Equipment: Bulletin: Subject: 2008 K Hemodialysis Machines 15-FRK-001 Rev A Optional Shunt Box Ferrite Core Installation (Update) 1.0 PURPOSE To inform

More information

Installation Instructions

Installation Instructions GE Consumer & Industrial Appliances Installation Instructions Junction Box Cover Within this user bag, you will find a junction box cover and a #10 hex head screw used to attach the junction box cover

More information

Toroidal Conductivity Sensor

Toroidal Conductivity Sensor Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:

More information

Installation Guide. 5 Series 15 W. Undercounter/Freestanding Nugget Ice Machine

Installation Guide. 5 Series 15 W. Undercounter/Freestanding Nugget Ice Machine Installation Guide 5 Series 15 W. Undercounter/Freestanding Nugget Ice Machine Table of Contents Warnings & Important Safety Instructions 3 Dimensions (Professional) 5 Dimensions (Custom Panel) 6 Specifications

More information

INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range. LRE3025ST LRE3025SB LRE3025SW

INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range. LRE3025ST LRE3025SB LRE3025SW ENGLISH ESPAÑOL INSTALLATION MANUAL ELECTRIC RANGE Please read these instructions thoroughly before installing and operating the range. LRE3025ST LRE3025SB LRE3025SW LRE3023ST LRE3023SB LRE3023SW Printed

More information

The Z-Bot Power Draw Bar

The Z-Bot Power Draw Bar The premier source of tooling, parts, and accessories for bench top machinists. The Z-Bot Power Draw Bar The Z-bot Power Draw Bar for mini mills is designed to work with the popular Tormach tooling system.

More information

20 Solar Heating System Item #s 6860, 6947 & 6945

20 Solar Heating System Item #s 6860, 6947 & 6945 20 Solar Heating System Item #s 6860, 6947 & 6945 INSTALLATION & OPERATION MANUAL Please read all instructions carefully before installing your system. Your warranty and your enjoyment of the Solar Heating

More information

Powers Controls TH 192 S Single Temperature Room Thermostat

Powers Controls TH 192 S Single Temperature Room Thermostat Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional

More information

Parts List. Safety Information. Additional Considerations. Retractable Security Cover Kit. Rocky Roller Kit

Parts List. Safety Information. Additional Considerations. Retractable Security Cover Kit. Rocky Roller Kit Parts List Retractable Security Cover Kit 3" PVC pipe with (4) 7'4" lengths of track (longer pools will have additional track pieces) Leading edge Optional cover pump (for outdoor installations) Rocky

More information

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100] Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100] PLEASE READ BEFORE INSTALLATION TO PREVENT DAMAGE TO THE COOLER HOT WATER TANK STEAM EXAUST VENT (CAUTION!)

More information

SOLAR SOLC201 On roof kit Installation Manual

SOLAR SOLC201 On roof kit Installation Manual SOLC201 On roof kit Installation Manual Page 1 of 32 0 Overall view Figure 1: Overall view of installation method Page 2 of 32 1 Contents 0 OVERALL VIEW 2 1 CONTENTS 3 2 BEFORE YOU START 4 2.1 GENERAL

More information

Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001

Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001 Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,

More information

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1967-72 CHEVROLET PICKUP

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1967-72 CHEVROLET PICKUP specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1967-72 CHEVROLET PICKUP CONTROL & OPERATING INSTRUCTIONS The controls on your new Perfect

More information

Rack and ball-bearing slide rails installation instructions

Rack and ball-bearing slide rails installation instructions Rack and ball-bearing slide rails installation instructions Important: If you are installing the server with an IBM MAX5 for System x, do not use these instructions. Instead, refer to the rack installation

More information

Installation and Operation Manual

Installation and Operation Manual dtm4 TANK MONITOR dtm8 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Parts Lists 7

More information

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Powers Controls TH 192 HC Heating/Cooling Room Thermostat Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional

More information

HOW TO REMOVE THE UPPER HEAD. FROM YOUR ATL-1,2,2+ or 3

HOW TO REMOVE THE UPPER HEAD. FROM YOUR ATL-1,2,2+ or 3 BULLETIN #B005A HOW TO REMOVE THE UPPER HEAD FROM YOUR ATL-1,2,2+ or 3 You will need: Standard blade screwdriver Phillips #1 head screwdriver Pliers For the ATL-2+ and ATL-3, the 3mm hex ball head driver

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

Optical Cable Entry Facility (OCEF) Installation Instructions

Optical Cable Entry Facility (OCEF) Installation Instructions Instruction Sheet 860380690 Issue 4, February 2014 Uniprise Solutions Optical Cable Entry Facility (OCEF) Installation Instructions General The Optical Cable Entry Facility (OCEF) cabinet stores optical

More information

Anemometer Arm with 40 feet (12.2 meters) of cable

Anemometer Arm with 40 feet (12.2 meters) of cable Standard Anemometer Installation Manual The anemometer measures and displays wind-related conditions such as wind speed, wind direction, wind run, wind chill, and the temperature-humiditysun-wind index.

More information

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1967 CHEVROLET IMPALA

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1967 CHEVROLET IMPALA specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1967 CHEVROLET IMPALA CONTROL & OPERATING INSTRUCTIONS The controls on your new

More information

Stainless Steel Single and Dual Circulation Kits

Stainless Steel Single and Dual Circulation Kits Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating

More information

400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors

400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors 400 and 400VP Series Product Data Sheet LIQ-PDS-400-400VP June 2016 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors No initial calibration required. Factory-measured cell constant ensures

More information

Figure 2 The fan and shroud also needs to be removed for access to the four a/c compressor bolts and removal of the compressor from the top.

Figure 2 The fan and shroud also needs to be removed for access to the four a/c compressor bolts and removal of the compressor from the top. Here are some pictures to show what s required when replacing the A/C compressor, expansion valve and receiver/drier on a 2001 Volvo V70. Even if you don t replace these A/C parts these pictures can help

More information

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual STATFlow Direct-to-Drain System For use with STATIM 2000 and STATIM 5000 Autoclaves Installation Guide and Operator s Manual STATFlow Installation Guide and Operator s Manual 95-113193 Rev 2.0. Copyright

More information

SOUND GUARD SST-E INSTALLATION INSTRUCTIONS & PARTS LIST

SOUND GUARD SST-E INSTALLATION INSTRUCTIONS & PARTS LIST SOUND GUARD SST-E INSTALLATION INSTRUCTIONS & PARTS LIST FOR DIESEL GENERATOR MODELS 8.0-10.0, 11.5, 12.6 EDT SOUND GUARD SST-E INSTALLATION INSTRUCTIONS & PARTS LIST FOR DIESEL GENERATOR MODELS 8.0-10.0,

More information

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL 4-2011

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL 4-2011 OWNER S MANUAL th DRAINVAC ATOMIK PRINTED APRIL 4-2011 INTRODUCTION We take this opportunity to express our gratitude and extend our congratulations for your decision to purchase a Drainvac product. A

More information

Installation Instructions 6028.801

Installation Instructions 6028.801 DAZZLE Installation Instructions 08.80 Spread Lavatory Faucet with Speed Connect Drain* Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American

More information

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug Electrical Connection When installed the range must be electrically grounded in accordance with local codes or; in the absence of local codes with the National Electrical Code ANSI/NFPA 70, latest edition.

More information

Ocean Engineering Technical Data Sheet Stuffing Tubes

Ocean Engineering Technical Data Sheet Stuffing Tubes Ocean Engineering Technical Data Sheet Stuffing Tubes Stuffing tubes are devices used to allow a wire or cable to pass through a wall or bulkhead and protect components from the outside environment. Many

More information

TANKWATCH 4 OWNER S MANUAL LEVEL MONITOR SYSTEM

TANKWATCH 4 OWNER S MANUAL LEVEL MONITOR SYSTEM TANKWATCH 4 LEVEL MONITOR SYSTEM OWNER S MANUAL 1 Dometic Corporation Sanitation Systems 13128 State Rt 226, PO Box 38 Big Prairie, OH 44611 SeaLand Product Customer Service: 1-800-321-9886 (8:00 a.m.

More information

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This

More information

Procedure: Installation for the GT28RS Turbo Upgrade for the Transverse Mounted 1.8T Golf/Jetta/GTI/Beetle Model Years 2000 to 2004

Procedure: Installation for the GT28RS Turbo Upgrade for the Transverse Mounted 1.8T Golf/Jetta/GTI/Beetle Model Years 2000 to 2004 Page 1 of 7 Procedure: Installation for the GT28RS Turbo Upgrade for the Transverse Mounted 1.8T Golf/Jetta/GTI/Beetle Model Years 2000 to 2004 Warning: Check local laws before adding turbo components

More information

Tech Article. Raingear Wiper System. From Newsletter st Quarter of Unabridged. 1. Disconnect your battery.

Tech Article. Raingear Wiper System. From Newsletter st Quarter of Unabridged. 1. Disconnect your battery. Parts you will need Danchuk # 12825 Raingear Wiper System with Intermittent Switch Danchuk # 12828 Raingear Universal Washer Kit Danchuk # 913 Wiper Switch Tool Danchuk # 912 Wiper Escutcheon Nut Tool

More information

ECOplus Solar Cylinder

ECOplus Solar Cylinder INSTALLATION INSTRUCTIONS Wagner& Co ECOplus Solar Cylinder Connection Diagram Hot water consumer circulation pump Backflow preventer CORREX-UP impressed current anode Safety valve, 10 bar Hot water connection,

More information

8/22/2005 JWT G35 / 350Z TWIN TURBO FUEL MANAGEMENT UNIT (FMU) INSTALLATION GUIDE ADDENDUM

8/22/2005 JWT G35 / 350Z TWIN TURBO FUEL MANAGEMENT UNIT (FMU) INSTALLATION GUIDE ADDENDUM 8/22/2005 JWT G35 / 350Z TWIN TURBO FUEL MANAGEMENT UNIT (FMU) INSTALLATION GUIDE ADDENDUM 1 1. Installing the new fuel pump and FMU. Wear eye protection and insure that you are working in a well-ventilated

More information

A1100 GUARDIAN COAXIAL OVERFILL PREVENTION SYSTEM

A1100 GUARDIAN COAXIAL OVERFILL PREVENTION SYSTEM A1100 GUARDIAN COAXIAL OVERFILL PREVENTION SYSTEM Assembly and Installation Instructions IMPORTANT: Read these instructions completely and carefully before attempting to install and operate this valve.

More information

AAM Competition 370Z Twin Pump Fuel System (2009- Present) INSTALLATION INSTRUCTIONS (DESIGNED FOR ONLINE USE AND COLOR PRINTING)

AAM Competition 370Z Twin Pump Fuel System (2009- Present) INSTALLATION INSTRUCTIONS (DESIGNED FOR ONLINE USE AND COLOR PRINTING) AAM Competition 370Z Twin Pump Fuel System (2009- Present) INSTALLATION INSTRUCTIONS (DESIGNED FOR ONLINE USE AND COLOR PRINTING) ***WARNING: PRODUCT(S) ARE DESIGNED FOR OFF-ROAD / COMPETITION USE ONLY***

More information

K27 Focus ST CCK Installation

K27 Focus ST CCK Installation 8967 Gilder Rd., Ste. A Houston, TX 77064-1286 281-890-4772 Sales@KozmicMotorsports.com K27 Focus ST CCK Installation Important: On the allen drain plug that is included in the kit - We recommend using

More information

Volkswagen New Beetle Body - Exterior 66 Exterior equipment (Page GR-66)

Volkswagen New Beetle Body - Exterior 66 Exterior equipment (Page GR-66) 66 Exterior equipment (Page GR-66) Wheel house liner, removing and installing Front wheel house liner Rear wheel house liner Rear view mirror Mirror glass, removing and installing Mirror housing, removing

More information

SUBJECT: EXHAUST GAS RECIRCULATION (EGR) SYSTEM RELEASED FOR THE SERIES 60 2002 ENGINE

SUBJECT: EXHAUST GAS RECIRCULATION (EGR) SYSTEM RELEASED FOR THE SERIES 60 2002 ENGINE NUMBER: 7 60 02 S.M. REF.: 6.6 ENGINE: 60 DATE: December 2002 SUBJECT: EXHAUST GAS RECIRCULATION (EGR) SYSTEM RELEASED FOR THE SERIES 60 2002 ENGINE INTRODUCTION Detroit Diesel has released an Exhaust

More information

Installation Guide 2010 BMW S1000RR Full Exhaust System

Installation Guide 2010 BMW S1000RR Full Exhaust System Installation Guide 2010 BMW S1000RR Full Exhaust System!! THIS PRODUCT IS DESIGNED FOR USE IN CLOSED COURSE RACING AND IS NOT INTENDED FOR HIGHWAY USE!! Congratulations on the purchase of your new TaylorMade

More information

Tools Required WARNING. Test Fit Key. Note BMW K 1600 GT / GTL SARGENT WORLD SPORT PERFORMANCE SEAT INSTALLATION GUIDE

Tools Required WARNING. Test Fit Key. Note BMW K 1600 GT / GTL SARGENT WORLD SPORT PERFORMANCE SEAT INSTALLATION GUIDE BMW K 1600 GT / GTL SARGENT WORLD SPORT PERFORMANCE SEAT INSTALLATION GUIDE To protect your heated seats from wiring, lock or key damage, please read all instructions carefully before beginning this installation.

More information

H41 Electrical Stage Aft Air Conditioner Unit Installation

H41 Electrical Stage Aft Air Conditioner Unit Installation Aft Air Conditioner Unit Installation 1. Place Air-Cond unit in A/C shelf with air return facing fwd direction of the boat. 2. Do not secure Air-Cond Unit on shelf, install both side of air condition ABS

More information

Instructions for: TTW 1 Universal Service Replacement Blower Kit P/N 265-47200-00

Instructions for: TTW 1 Universal Service Replacement Blower Kit P/N 265-47200-00 Instructions for: TTW 1 Universal Service Kit P/N 265-47200-00 (To be performed ONLY by qualified service providers) The Blowers on the Following Water Heaters are Serviced by This Kit: MITW -10 Series

More information

VTA Series Pneumatic Three Way Air Switching Valves

VTA Series Pneumatic Three Way Air Switching Valves FANs 718, 977 Product Bulletin VTA Series Issue Date 0596 VTA Series Pneumatic Three Way Air Switching Valves The VTA Series Three Way Air Switching Valves are designed to switch the flow of air from onesupply

More information

GLOBE FLOWCELL. Operating Manual. ROLA-CHEM Flowcell PN /17/2015 page: 1 of 8

GLOBE FLOWCELL. Operating Manual. ROLA-CHEM Flowcell PN /17/2015 page: 1 of 8 GLOBE FLOWCELL Operating Manual ROLA-CHEM Flowcell PN 550182 09/17/2015 page: 1 of 8 Table of Contents Section title Page 1. Safety Instructions 2 2. Description 2 3. Installation 3 4. Use of Flowcell

More information

Submersion/Insertion Toroidal Sensor

Submersion/Insertion Toroidal Sensor Instruction Sheet PN 51A-228/rev.P December 2010 Model 228 Submersion/Insertion Toroidal Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION SENSOR/PROCESS

More information

STERNMOUNT MARINE TOWER KIT OWNER S MANUAL

STERNMOUNT MARINE TOWER KIT OWNER S MANUAL STERNMOUNT MARINE TOWER KIT OWNER S MANUAL VERSION 1.5 Made in the USA by: Southwest Windpower 1801 W. Route 66 Flagstaff, AZ 86001 (520) 779-9463 AIR Marine is a trademark of Southwest Windpower Inc.

More information

Solstice/Sky Water Pump Replacement

Solstice/Sky Water Pump Replacement Solstice/Sky Water Pump Replacement The water pump on the Solstice/Sky is starting to need replacement on some vehicles. This guide will help in replacing the water pump while the engine is still in the

More information

31000 and Proximity Probe Housings Bently Nevada* Asset Condition Monitoring

31000 and Proximity Probe Housings Bently Nevada* Asset Condition Monitoring 31000 and 32000 Proximity Probe Housings Bently Nevada* Asset Condition Monitoring Description The 31000/32000 Proximity Probe Housing Assemblies are recommended when mounting proximity probes through

More information

DETACHABLE WINDSHIELD AND DOCKING HARDWARE KIT

DETACHABLE WINDSHIELD AND DOCKING HARDWARE KIT -J00 REV. 00-- DETACHABLE WINDSHIELD AND DOCKING HARDWARE KIT GENERAL Kit Number -A, 0-, -, 0-, -, - 0, -0 Models These kits fit and later FXST, FXSTB, FXSTC, and and later FXDWG Harley-Davidson model

More information

Before installation it is important to know what parts you have and what the capabilities of these parts are.

Before installation it is important to know what parts you have and what the capabilities of these parts are. INSTALLATION GUIDE Before installation it is important to know what parts you have and what the capabilities of these parts are. The Recon XZT is the smallest and most powerful gauge of its kind. With

More information

Upgrading a GainMaker Line Extender from a Line-Powered Source to a 120 V AC-Powered Source Installation Instructions

Upgrading a GainMaker Line Extender from a Line-Powered Source to a 120 V AC-Powered Source Installation Instructions Upgrading a GainMaker Line Extender from a Line-Powered Source to a 120 V AC-Powered Source Installation Instructions Overview Audience These installation instructions are intended for all cable system

More information

High Performance Weight Distribution and Dual Cam HP Cequent Towing Products

High Performance Weight Distribution and Dual Cam HP Cequent Towing Products Towing laws vary from state to state, province to province, please check To confirm safety requirements of the state/province where you Are located and towing. WARNING Cequent hitches are designed to safely

More information

LIEBERT VNSA Installation Sheet

LIEBERT VNSA Installation Sheet LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display

More information

Setting Up the Polycom RealPresence Utility Cart 500

Setting Up the Polycom RealPresence Utility Cart 500 Setting Up the Polycom RealPresence Utility Cart 500 Polycom EagleEye TM IV camera 27 display or (2) 22 displays Microphone and 25 cable Base cart with laptop/accessory shelf Storage drawer Accessory basket

More information

ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH

ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH The original design of the 03 Alpine Coaches (and perhaps other years as well) did not include any kind of engine fan engage mechanism

More information

Gas Ranges Installation Guide

Gas Ranges Installation Guide Gas Ranges Installation Guide GAS RANGES Contents 3 Safety Precautions 4 Specifications 7 Installation 10 Troubleshooting Features and specifications are subject to change at any time without notice. Visit

More information

2800 Series POS System

2800 Series POS System 2800 Series POS System Installation Guide Congratulations on your purchase of UTC RETAIL s innovative 2800 Series POS System! This fully integrated point-of-sale hardware solution, with its modular design

More information

Teledyne Isco Syringe Pumps: Care and Maintenance

Teledyne Isco Syringe Pumps: Care and Maintenance Teledyne Isco Syringe Pumps: Care and Maintenance ~ Overview ~ This bulletin provides instructions for performing normal periodic maintenance required by Teledyne Isco syringe pumps, followed by servicing

More information

How To... SERVICE AND REPAIR

How To... SERVICE AND REPAIR SECTION III How To... SERVICE AND REPAIR Page Pedals, Crank Arms, and Side Shrouds...3 Crank Shaft Hub Assembly...5 Crank Shaft and Bearings...7 Clutch Assembly...10 Intermediate Pulley Shaft and Bearings...11

More information

TECHNICAL DATA SHEET LS-1 Limit Switch

TECHNICAL DATA SHEET LS-1 Limit Switch TECHNICAL DATA SHEET LS-1 Limit Switch 2 Otter Court, Raymond, New Hampshire 03077 Tel. (603) 895-4761 FAX (603) 895-6785 www.geminivalve.com DESCRIPTION The LS-1 limit switch easily mounted to any Gemini

More information

Rack Installation Instructions

Rack Installation Instructions Rack Installation Instructions Second Edition (June 2014) 2014 Contents Chapter 1. Safety information..... 1 Chapter 2. Rack kit parts inentory... 3 Chapter 3. Rack installation...... 5 Identifying the

More information

G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS Service Literature G26 SERIES UNITS G26 series units are high-efficiency upflow gas furnaces manufactured with DuralokPlust aluminized steel clamshell-type heat exchangers. G26 units are available in heating

More information

Jacketed Tubing and Insulated Tubing

Jacketed Tubing and Insulated Tubing Jacketed Tubing and Insulated Tubing Installation Instructions These instructions provide the user with information for installation of Swagelok jacketed and insulated tubing. For additional information,

More information

WALL-MOUNT WASH STATION

WALL-MOUNT WASH STATION YOU WILL NEED: Phillips Screwdriver Leveling Device Drill 5/32 inch Hex Key Drill Bits: 1/4 inch (6.4 mm) 1/2 inch (13 mm) Power Screwdriver With Phillips Bit Shims (provided in hardware kit) R A-DEC INC.

More information

StorageWorks Solutions 5¼-Inch SBB Half-Height Device Installation Guide

StorageWorks Solutions 5¼-Inch SBB Half-Height Device Installation Guide StorageWorks Solutions 5¼-Inch SBB Half-Height Device Installation Guide Order Number: EK SBB55 IG. B01 This publication describes the 5¼-Inch StorageWorks building block components (such as covers, connectors,

More information

Dual Fuel Ranges Installation Guide

Dual Fuel Ranges Installation Guide Dual Fuel Ranges Installation Guide DUAL FUEL RANGES Contents 3 Safety Precautions 4 Specifications 7 Installation 11 Troubleshooting Features and specifications are subject to change at any time without

More information