PSM-ME-RS232/RS485-P Interface converter for RS-232 to RS /4-wire or RS-422
|
|
- Amberly Nelson
- 7 years ago
- Views:
Transcription
1 PSM-ME-/-P Interface converter for RS- to RS- -/-wire or RS-. Short Description The PSM-ME-/-P rail-mountable and compact interface converters have been designed especially for industrial use in the switch cabinet or switch box. They convert the RS- interface signals bidirectionally to the RS- -/-wire and RS- standard. The devices are simply snapped onto standard EN mounting rails and supplied with V DC or AC. Their particular feature is the multifunctional application: RS- master interface in RS- bus systems Networking RS- equipment RS- range increase to 000 m as interferencefree and fast point-to-point connection RS- interface adaptation to RS- and RS- systems The following features of the interface converter are particularly outstanding: operating modi can be configured - RS- RS---wire - RS- RS---wire - RS- RS- Can be used universally in all common bus systems with UART/NRZ data format and 0/ bits character length Transmission rate can be set between. kbit/s and. Mbit/s Automatic transmit/receive changeover High-quality -way isolation (VCC // RS- // RS-) Integrated surge voltage protection with transient discharge to the mounting rail Supply voltage of V DC or AC to suit the switch cabinet Minimal current consumption/power dissipation If you have any technical questions, please contact us at: PSM-HOTLINE:+/(0) /-0 FAX:+/(0) /- interface-service@phoenixcontact.com Headquarters: Phoenix Contact GmbH & Co. KG Flachsmarktstraße Blomberg Germany Phone +-(0) --00 Fax +-(0)
2 PSM-ME-/-P Interface converter for RS- to RS- -/-wire or RS-.. Sample applications... RS- // RS- interface converter RS- RS- The RS- standard is specified for applications with multipoint connections. We distinguish between -wire bus systems with half-duplex transmission and -wire bus systems with full-duplex transmission: RS- master adaptation (fig. a) Programming /and parameterizing connection (fig. a) Networking RS- stations (the software must guarantee that the stations can be addressed; (fig. b) Fig. a Fig. b RS- RS- RS- PSM ME / P Ord.-No.: PSM ME / P Ord.-No.: PSM ME / P Ord.-No.: PSM ME / P Ord.-No.: PSM ME / P Ord.-No.: PSM ME / P Ord.-No.: max. stations Fig.... RS- // RS- interface converter RS- RS- The RS- interface is a balanced to earth interface for point-to-point connections. The logical states are represented by a differential voltage between two lines. Areas of application are: Interface adaptation to RS- devices (fig. a). Interference-free and fast point-to-point connection up to 000 m (fig. b) fig. a PSM ME / P Ord.-No.: PSM ME / P Ord.-No.: PSM ME / P Ord.-No.: RS- RS- RS- Fig. b Fig. PHOENIX CTACT page of
3 PSM-ME-/-P Interface converter for RS- to RS- -/-wire or RS-. Order data Type Order No. Pcs. Pkt. Interface converter, for the conversion of RS- to RS- -/-wire or RS-, with electrical -way isolation, rail-mountable PSM-ME-/-P.. Accessories Compact power supply, primary switchedmode, V DC, 0 ma, rail-mountable RS- cable, m, to connect the PSM-ME converter to a -pos. device interface RS- cable, m, to connect the PSM-ME converter to a -pos. device interface SUB-D plug, -pos., with screw connection for free assembly of an RS- cable 0 V AC 0 V AC SUB-D/SUB-D (socket/socket) SUB-D/SUB-D (socket/socket) socket pin MCR-PS 0 AC/ DC/0 MCR-PS 0 AC/ DC/0 PSM-KA-SUB /BB/METER PSM-KA-SUB /BB/METER 0 SUBC /F-SH SUBC /M-SH 0.. Technical Data Supply voltage Frequency Rated current consumption Connection LED operational availability RS- interface Type of transmission Coding option Data indicator Transmission rates in kbit/s Transmission length Connection V AC/DC ± 0 % DC-0 Hz typ. ma pluggable COMBIC screw terminal block LED green acc. to DIN T, CCITT V. transparent to protocol /DCE switchover via DIP switch LED green (RD) RS- receive data (dynamic) LED yellow (TD) RS- transmit data (dynamic).;.;.;.;.; ;.; m shielded (recommended from. kbit/s, max. m in industrial applications) -pos. SUB-D pin strip RS-/RS- interface Interface standards Data format/coding Character length Tri-State Transmission rates in kbit/s Transmission length Data direction switching Terminating resistances Connection. General data data/shield acc. to DIN - RS- -wire, half duplex, RS- -wire, full duplex, RS-, full duplex, can be configured via DIP switch UART/NRZ ), 0/ bit. bit after start bit edge corresponding to the RS- interface m, twisted pair, shielded either automatic control or control via RS- RTS/CTS RTS/CTS V, transmit in direction of RS- Inversion possible via DIP switch switchable, 0 Ω pull up/down, 0 Ω terminating resistance pluggable COMBIC screw terminal block /shield connector Protection circuit Transient discharge Electrical -way isolation Test voltage Resistance to vibration Ambient temperature range Protection type Housing: Connection data (conductor cross section) - COMBIC plug connectors Weight Approval Material Dimensions (W / H / D) Y-capacitors, suppressor diodes, gas-filled surge arresters via metal foot on EN mounting rail power supply // RS- // RS-/RS- kvrms, 0 Hz, min. g in acc. with IEC -- 0 C to + C IP 0 PA-V0 ( /. /.) mm mm (AWG -) approx. 0 g u ) NRZ: Non Return To Zero PHOENIX CTACT page of
4 , PSM-ME-/-P Interface converter for RS- to RS- -/-wire or RS- c Complies with EMC guideline //EEC EMC (electromagnetic compatibility) Immunity to interference in acc. with EN 00- Electrostatic discharge (ESD) Electromagnetic HF field: Amplitude modulation: Pulse modulation: Fast transients (Burst) Signal: Supply: Surge voltage capacities (Surge) Signal: Supply: Conducted disturbance Noise emission in acc. with EN 00- EN EN EN EN EN EN 0 Criterion B kv discharge in air kv contact discharge Criterion A 0 V/m 0 V/m Criterion B kv/ khz kv/ khz Criterion B kv/ Ω 0. kv/ Ω Criterion A 0 V Class A EN 000 corresponds to IEC 000 EN 0 corresponds to CISPR Criterion A: Normal operating behavior within the defined limits. Criterion B: Temporary impairment of operational behavior that the device corrects itself. Class A: Area of application: industry, without special installation measures., Fig. PHOENIX CTACT page of
5 RS - Device-Typ DCE (kbit/s) OFF /RS, OFF OFF, OFF, OFF OFF, OFF OFF, OFF OFF OFF OFF, OFF OFF, OFF OFF FUNC. OFF RTS/CTS-CTROLLED SELF-CTROLLED RS - Wire / Wire RS - VCC PSM-ME-/-P Interface converter for RS- to RS- -/-wire or RS- Function elements (fig. ) Supply voltage V AC/DC LED Supply voltage (VCC) LED-RS- receive data (RD) LED-RS- transmit data (TD) RS- interface connection RS-/RS- interface connection Shield connector Snap-on foot for mounting rails in acc. with DIN EN 0 0 PSM-ME-/-P Ord.-Nr.: PSM-ME-/-P Art.-Nr.: RTS/CTS INVERS RTS/CTS STANDARD -WIRE -WIRE RS APPROBATIEN / APPROVALS APPROBATIEN / APPROVALS Fig.. Operational Diagram SUB - D pole Steckbare Schraubklemme Screw terminal block Bloc de jonction a`vis Borne de tornillo +V +V V V OV OV TxD DCE +V (Port B) +V (Port A) gn DIP Wire OFF 0Ω 0Ω 0Ω 0Ω 0Ω 0Ω RxD RTS CTS DSR DTR DIP DATA RATE (RTS / CTS) OFF (RTS / CTS) gn ye OFF DIP Bus - Management Wire DIP OFF (RS ) (RS ) +V T(A) T(B) Shield Fig. PHOENIX CTACT page of
6 Device-Typ DCE OFF /RS (kbit/s), OFF OFF, OFF, OFF OFF, OFF OFF, OFF OFF OFF OFF, OFF OFF, OFF OFF FUNC. OFF PSM-ME-/-P Interface converter for RS- to RS- -/-wire or RS-. Notes on connection V.. Connections (fig. ) Plug connector power supply Connect V AC/DC ± 0 % via the COMBIC plug connector (PIN and ). Operational availability is signaled via the VCC LED. 0 V RS- interface -pos. SUB-D pin strip RS-/RS- interface pluggable COMBIC screw terminal block PSM ME / P Ord.-No.: Fig... Mounting in the switch cabinet (fig. ) Mounting (on mm mounting rails in acc. with DIN EN 0 0): Hinge the device into the upper edge of the mounting rail and snap it in with a downward motion. Note: The mounting rail must be connected to ground potential. This is the only way to guarantee that the integrated surge voltage protection functions and that the shield of the bus conductor makes contact effectively. Dismantling: Pull back the metal disassembling lever with the aid of a screwdriver and remove the device from the top. PSM-ME-/-P Ord.-Nr.: RTS/CTS-CTROLLED SELF-CTROLLED RTS/CTS INVERS RTS/CTS STANDARD -WIRE -WIRE RS PSM-ME-/-P Art.-Nr.: APPROBATIEN / APPROVALS APPROBATIEN / APPROVALS Fig. PHOENIX CTACT page of
7 Device-Typ DCE OFF /RS (kbit/s), OFF OFF, OFF, OFF OFF, OFF OFF, OFF OFF OFF OFF, OFF OFF, OFF OFF FUNC. OFF OFF /RS FUNC. OFF RTS/CTS-CTROLLED SELF-CTROLLED PSM-ME-/-P Interface converter for RS- to RS- -/-wire or RS-. The RS- interface Designation SUB-D -pos. (pin) Transmit data TXD PIN Receive data RXD PIN Clear to send CTS PIN Request to send RTS PIN Functional ground PIN DEE data terminal ready DTR PIN Data set ready DSR PIN Ground Shield.. Interface coupling PSM-ME-... SUB-D -pos. (pin) TxD RxD CTS RTS DTR DSR Max. m peripherals side SUB D 0 TxD RxD CTS RTS DTR DSR Make a -to- connection between the PSM module and the peripheral device as shown in Fig.. Fig. Note: For a minimum configuration, you need to connect TXD, RXD and (software handshake)! Connect the -pos. SUB-D plug to the module (fig.0)... Data indicator Two diagnostic LEDs indicate the RS- interface modes Yellow: Transmit data (TD), dynamic Green: Receive data (RD), dynamic PSM-ME-/-P Ord.-Nr.: Ord.-Nr.: PSM-ME-/-P Art.-Nr.: RTS/CTS-CTROLLED SELF-CTROLLED RTS/CTS INVERS RTS/CTS STANDARD -WIRE -WIRE RS APPROBATIEN / APPROVALS APPROBATIEN / APPROVALS.. Configuration For configuration, release the top of the housing on both sides. Pull the p.c.b. out of the housing as far as possible (fig. ). Static charges can damage electronic devices. Discharge the electrical charge from your body before opening and configuring the device. To do so, touch a grounded surface, e.g. the metal housing of the switch cabinet. Fig. 0 PSM-ME-/R Ord.-Nr.: RTS/CTS INVERS RTS/CTS STANDARD -WIRE -WIRE RS APPROBATIO PPROBATIO Fig. PHOENIX CTACT page of
8 RS - PSM-ME-/-P Interface converter for RS- to RS- -/-wire or RS-.. /DCE switchover (fig. ) The /DCE slide switches can be used to cross the cables TXD and RXD as well as RTS and CTS internally so that an adaptation to or DCE interfaces can be performed easily. /DCE For the connection to: Data terminal equipment () switch to position. (Standard setting for most applications) Data communication equipment (DCE) switch to position DCE. If the connected interface type is unknown, you can determine the right configuration by trial and error (/DCE switch). /RS OFF FUNC. OFF RTS/CTS-CTROLLED SELF-CTROLLED RTS/CTS INVERS RTS/CTS STANDARD -WIRE -WIRE RS PSM-ME-/-P Art.-Nr.: DCE Device-Typ P, OFF OFF, OFF, OFF OFF, OFF OFF, OFF OFF OFF OFF, OFF OFF, OFF OFF APPROBATIEN / APPROVALS (kbit/s) 0 0 Fig... CTS/RTS support (DIP switch ) In normal operating mode, no control lines (RTS/ CTS) are required for data direction switching (switch position DIP "OFF"). The data direction switching can alternatively be controlled through the RTS/CTS lines. Set the DIP switch to the "" position. TxD DCE S Function: RTS/CTS V to V = RS- receive mode RTS/CTS + V to + V = RS- transmit mode RxD RTS CTS DIP (RTS / CTS) OFF (RTS / CTS).. RTS/CTS inversion (DIP switch ) DSR In uncommon applications, the control lines must be inverted. Set the DIP switch to the "" position (default: "OFF"). The signal position in inverse mode is then as follows: DTR DATA RATE Bus - Man RTS/CTS + V to + V = RS- receive mode RTS/CTS - V to - V = RS- transmit mode Fig. PHOENIX CTACT page of
9 OFF /RS, OFF FUNC. RTS/CTS-C RTS/CT PSM-ME-/-P Interface converter for RS- to RS- -/-wire or RS-. The RS-/RS- interface.. Operation as RS- -wire interface PSM-ME-RS- PSM-ME-RS- Pin configuration Designation COMBIC (pin) Data line (+) PIN Data line ( ) PIN Signal ground PIN Ground/shielded connection PIN Settings: Shield COMBIC Fig. ) As described in the section "RS- interface", set the operating mode of the RS- interface with DIP switch and and the type of interface with the /DCE switchover switch. RS- /DCE Note: If automatic operating mode is selected, no control lines from the RS- interface are required. ) If the automatic operating mode was selected, set the transmission rate with the aid of DIPswitches S-S (fig. ) and the table below. All PSM converters and bus stations must be set to the same transmission rate! /RS OFF FUNC. O RTS/CTS-CTROLLED SELF-CO RTS/CTS INVERS RTS/CTS -WIRE - RS R PSM-ME-/-P Art.-Nr.: DCE Device-Typ P, OFF, OFF, OFF, OFF OFF, OFF OFF OFF, OFF, OFF OFF (kbit/s) 0 0 Fig. The interface converters only convert an electric signal. ) Set DIP switch to position "OFF" to activate the RS- operating mode. ) Set DIP switch to "OFF" to activate the -wire mode. ) If necessary, activate the terminating resistors fig. (Please observe the section on "Terminating resistor for the RS-/RS- interface", page ). ) To couple two RS- interfaces, connect the connections acc. to fig.. ( = twisted pair) connection is recommended, but is not essential. Shielding the data cables The data cables are shielded using a shield terminal block that is fixed in the terminal block (fig. ). The terminal block is connected capacitively to the mounting rail contact on the underside of the device. The shield connector is included in the scope of delivery. Use shielded twisted pair cables. Connect the cable shield to both sides of the transmission path! (B) T(A) T(B) SPEED DIP (kbit/s), OFF OFF. OFF. OFF OFF. OFF OFF. OFF OFF OFF OFF. OFF OFF. OFF OFF RS Fig. FUNC. DIP OFF RTS/CTS-CTROLLED SELF-CTROLLED RTS/CTS INVERS RTS/CTS STANDARD -WIRE -WIRE RS PHOENIX CTACT page of
10 OFF /RS,, OFF FUNC. RTS/CTS-CTR RTS/CTS INVE PSM-ME-/-P Interface converter for RS- to RS- -/-wire or RS-.. Operation as RS- -wire interface Pin configuration Designation COMBIC (pin) Receive data (+) PIN Receive data ( ) PIN Transmit data (+) T(B) PIN Transmit data ( ) T(A) PIN Signal ground PIN Ground/shielded connection PIN Settings: ) Set as described in the section "RS- interface" the operating mode of the RS- interface using DIP switch and and the type of interface with the /DCE switchover switch. Note: If automatic operating mode is selected, no control lines from the RS- interface are required. ) If the automatic operating mode was selected, set the transmission rate with the aid of DIP-switches S-S (fig. ) and the table below. All PSM converters and bus stations must be set to the same transmission rate! PSM-ME-RS- T(B) T(A) RS- Shield /RS OFF FUNC. O RTS/CTS-CTROLLED SELF-CO RTS/CTS INVERS RTS/CTS -WIRE - RS R COMBIC PSM-ME-/-P Art.-Nr.: DCE Device-Typ P, OFF, OFF, OFF, OFF OFF, OFF OFF OFF, OFF, OFF OFF (kbit/s) 0 0 PSM-ME-RS- /DCE T(B) T(A) Fig. Fig. The interface converters only convert an electric signal. ) Set DIP switch to position "OFF" to activate the RS- operating mode. ) Set DIP switch to "" to activate the -wire mode. ) If necessary, activate the terminating resistors fig. (Please observe the section on "Terminating resistor for the RS-/RS- interface", page ). ) To couple two RS- interfaces, connect the connections acc. to fig.. ( = twisted pair) When connecting the device, take into account that it is necessary to cross transmitted and received data. connection is recommended, but is not essential. Shielding the data cables The data cables are shielded using a shield terminal block that is fixed in the terminal block (fig. ). The terminal block is connected capacitively to the mounting rail contact on the underside of the device. The shield connector is included in the scope of delivery. Use shielded twisted pair cables. Connect the cable shield to both sides of the transmission path! ) T(B) -WIR RS P A Fig. SPEED DIP (kbit/s), OFF OFF. OFF. OFF OFF. OFF OFF. OFF OFF OFF OFF. OFF OFF. OFF OFF FUNC. DIP OFF RTS/CTS-CTROLLED SELF-CTROLLED RTS/CTS INVERSE RTS/CTS STANDARD -WIRE -WIRE RS PHOENIX CTACT page 0 of
11 OFF /RS, OFF OFF OFF OFF, OFF OFF, OFF OFF FUNC. OFF RTS/CTS-CTROLLED SELF-CTROLLED RTS/CTS INVERS RTS/CTS STANDARD PSM-ME-/-P Interface converter for RS- to RS- -/-wire or RS-.. Operation as RS interface Pin configuration Designation COMBIC (pin) Receive data (+) PIN Receive data ( ) PIN Transmit data (+) T(B) PIN Transmit data ( ) T(A) PIN Signal ground PIN Ground/shielded connection PIN Settings: ) Set the DIP switch to position. "" to activate the RS- operating mode (fig. ). ) Set as described in the section "RS- interface" the interface type of the RS- interface with the /DCE switchover switch. Note: In this operating mode, no control lines from the RS- interface are required and none are transmitted. PSM-ME-RS- T(B) T(A) RS- "" Shield COMBIC PSM-ME-RS- /DCE T(B) T(A) Fig. 0 ) Switch the line terminating resistor on both sides of the RS transmission link on. Put "" slide switch to "". ) To couple two RS- interfaces, connect the connections acc. to fig. 0. ( = twisted pair) When connecting the device, take into account that it is necessary to cross transmitted and received data. connection is recommended, but is not essential. /RS OFF FUNC. OFF RTS/CTS-CTROLLED SELF-CTROLLED RTS/CTS INVERS RTS/CTS STANDARD -WIRE -WIRE RS PSM-ME-/-P Art.-Nr.: DCE Device-Typ P, OFF OFF, OFF, OFF OFF, OFF OFF, OFF OFF OFF OFF, OFF OFF, OFF OFF (kbit/s) 0 0 DIP APPROBATIEN / APPROVALS Fig. Shielding the data cables The data cables are shielded using a shield terminal block that is fixed in the terminal block (fig. ). The terminal block is connected capacitively to the mounting rail contact on the underside of the device. The shield connector is included in the scope of delivery. PSM-M Art.-N Use shielded twisted pair cables. Connect the cable shield to both sides of the transmission path! -WIRE -WIRE RS OBATIEN / A ATIEN / Fig. PHOENIX CTACT page of
12 S PSM-ME-/-P Interface converter for RS- to RS- -/-wire or RS-. Set the line terminating resistor correctly in RS- and RS- mode. A connectable line terminating resistor is integrated in the converter and it must be switched on or off, depending on the application. PSM ME / P Ord.-No.: PSM ME / P Ord.-No.:.. In RS- mode (/-wire) RS- is the standard for a multi-point-capable connection (up to terminals). The RS- bus line may only be terminated at the two most distant bus ends. "" slide switch to "" at the beginning and end of the bus line (fig. ). PSM ME / P Ord.-No.: = Bus terminating resistor "" Fig... In RS- mode RS- is the standard for a point-to-point connection between two devices. The line terminating resistor on both sides of the RS- transmission link must be switched on. "" slide switch always in "" position (fig. ). PSM ME / P Ord.-No.: PSM ME / P Ord.-No.: = Terminating resistor "" Fig. PHOENIX CTACT page of RS /RS /RS OFF FU PSM-ME-/-P Art.-Nr.: DCE Device-Typ 0 Fig. PHOENIX CTACT 0.0. TNR: 0-0
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
More informationMCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description
Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V
More informationPSI-REP-PROFIBUS/12MB
Repeater for PROFIBUS Systems up to 12 Mbps INTERFACE Data Sheet 102986_02_en PHOENIX CONTACT - 03/2007 1 Description The PSI-REP-PROFIBUS/12MB DIN rail-mountable modular PROFIBUS repeater is designed
More informationRedundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
More informationRack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
More informationPower Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/2x15DC/1
Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/2x15DC/1 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of
More informationTelephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
More informationPower Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/24DC/2
Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/24/2 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of operational
More informationExtract from the online catalog
Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The
More informationMINI MCR-SL-R-UI(-SP)
Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts
More informationPSI-DATA/FAX-MODEM/RS232
Industrial analog modem INTERFACE Data sheet 100500_en_01 PHOENIX CONTACT - 10/2008 1 Description The DIN rail-mountable PSI-DATA/FAX-MODEM/RS232 is specifically designed to meet industrial requirements
More informationManual Serial PCI Cards
Manual Serial PCI Cards W&T Models 13011, 13410 13411, 13610 13611, 13812 Version 1.4 Subject to error and alteration 37 01/2005 by Wiesemann & Theis GmbH Subject to errors and changes: Since we can make
More informationSerial Bluetooth Converter for V.24 (RS-232), RS-422, and RS-485 2-Wire Bus Systems PSI-WL-RS232-RS485/BT
Serial Bluetooth Converter for V.24 (RS-232), RS-422, and RS-485 2-Wire Bus Systems PSI-WL-RS232-RS485/BT 1. Description The Bluetooth converter provides a quick and easy wireless connection between serial
More informationPCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
More informationWaveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
More informationABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
More informationRS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info
RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals
More informationModular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
More informationTX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
More informationRISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
More informationApplication. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11
Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks. The MPU handles the absolute time and
More informationPCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version 2.1.0 (2013-11-15)
PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN User Manual Document version 2.1.0 (2013-11-15) Products taken into account Product Name Model Part number PCAN-B10011S IPEH-002041 CANopen
More informationPSI-MOS-RS485W2/FO 850 T
Extract from the online catalog PSI-MOS-RS485W2/FO 850 T Order No.: 2708326 FO converter with integrated optical diagnosis, alarm contact, for RS-485 2-wire bus systems (SUCONET K, MODBUS...) up to 500
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationElectronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationSingle-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationPHOENIX CONTACT - 01/2007
Uninterruptible power supply INTERFACE Data Sheet 103123_00_en PHOENIX CONTACT - 01/2007 Description Especially compact and easy-to-use, the new MINI-DC-UPS/ 24 DC/2 is a combination of the power supply
More informationABB Drives. User s Manual HTL Encoder Interface FEN-31
ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions
More information38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
More informationconnecdim Gateway G1 Ethernet TCP/IP to DALI
Gateway G1 Ethernet TCP/IP to LI Independent lighting control for up to 256 LI gears on 4 LI lines Can be expanded by connecting multiple gateways on the same network Cloud based web interface for configuration
More informationDEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050
Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationMounting instructions. Junction box VKK2R-8 DIGITAL. A1145-1.0 en
Mounting instructions Junction box VKK2R-8 DIGITAL VKK2R-8 DIGITAL 3 Contents Page Safety instructions... 4 1 Introduction and appropriate use... 7 2 Mechanical construction... 8 2.1 Mounting... 9 3 Electrical
More informationTM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More informationis then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
More informationR4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
More informationCommunication Unit 560CMU05 Data sheet
RTU560 product line Communication Unit 560CMU05 Data sheet E1 10/100 MB LAN E2 10/100 MB LAN CP1, CP2 RS232C or RS485 Ethernet Controller Ethernet Controller USART Processor bus MPU ELAN520 /Flash Memory
More informationPHOENIX CONTACT - 2012-12-14. Features
Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed
More informationAnalog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
More informationProcess modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
More informationAutomation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
More informationProduct and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
More informationHARTING mcon 1000 Introduction and features
Introduction and features HARTING mcon 1000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features Supporting Ethernet (10 Mbit/s), Fast Ethernet (100 Mbit/s)
More informationMasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
More information48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
More information15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE
Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer
More information48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
More informationProgrammable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
More information40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52
Features 40.31 40.51 40.52 1 & 2 Pole relay range 40.31-1 Pole 10 A (3.5 mm pin pitch) 40.51-1 Pole 10 A (5 mm pin pitch) 40.52-2 Pole 8 A (5 mm pin pitch) PCB mount - direct or via PCB socket 35 mm rail
More informationChrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited
More informationHARTING mcon 3000 Introduction and features
Introduction and features HARTING mcon 3000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features The fully managed es of the product family HARTING mcon
More information34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51
34 Series - Slim electromechanical PCB relays 6 34 SERIES Features 34.51 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in
More informationProvides one channel for Ethernet over existing
LB304A LBPS301A LBPS304A Hardened Ethernet Extender Quick Start Guide Provides one channel for Ethernet over existing voice-grade copper twisted-pair wire. copper BLACK wire. BOX Customer Support Information
More informationSTEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
More informationHARTING econ 3000 Introduction and features
HARTING Introduction and features HARTING es, unmanaged, for installation in control cabinets General Description Features The Fast es of the product family HARTING are suitable for industrial applications
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationMasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic
More informationVoltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
More informationVoltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More informationThree-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
More informationEMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH
ENGLISH EMOSAFE EN-100 Product Data Sheet Network Isolators for PCB assembly November 2013 1 GENERAL DESCRIPTION The EMOSAFE EN-100 Network Isolator interrupts all galvanically conducting connections (conductors
More informationProvides one channel for Ethernet over existing
LB304A LBPS301A LBPS304A Hardened Ethernet Extender Quick Start Guide Provides one channel for Ethernet over existing voice-grade copper twisted-pair wire. copper BLACK wire. BOX Customer Support Information
More informationTECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)
More informationABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
More information80 Series - Modular timers 16 A. Features 80.01 80.11
80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h
More informationPD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
More informationControl Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationTemperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
More informationOperating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA
Order Number: 8160.UANA Status: V6; 1425.03.2010 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 ANACON UMB ANALOGUE/DIGITAL CONVERTER...
More informationRelés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
More informationFOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationFixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits
Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay
More informationMDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference : 9010709-03
MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE USER GUIDE Document reference : 9010709-03 If you have questions about the MDM192 or desire assistance, contact ETIC TELECOMMUNICATIONS at the following
More informationFOM-5A, 6A. Asynchronous Fiber Optic Modem
FOM-5A, 6A Asynchronous Fiber Optic Modem FEATURES Asynchronous transmission at up to 19.2 kbps Transmission range up to 3 km (1.8 mi), regardless of data rate Full- or half-duplex Transfers one control
More informationMy first Hirschmann: The SPIDER family of switches.
My first Hirschmann: The SPIDER family of switches. Large selection of entry level switches Compact design Simple rail installation Industry standard 24 V supply voltage Plug & Play gets you up and running
More informationChrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range
More informationPHOENIX CONTACT - 03/2007
PSI-WL-PLUG-USB/ Bluetooth USB Adapter INTERFACE Data Sheet 103170_00_en PHOENIX CONTACT - 03/2007 Description The Bluetooth USB adapter provides an easy wireless connection between devices with a USB
More informationJUMPFLEX 857 Series. 0...20 ma 2...10 V. 4...20 ma. Transducers / Relay and Optocoupler Modules
0888-0172/0002-3601 JUMPFLEX 857 Series 2.0 E 12/08 Printed in Germany Subject to design changes 2...10 V 0...20 ma 4...20 ma WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 32385 Minden Hansastraße 27
More information93.68/93.69. Time scale: from 0.1s to 6h Multi-function For use with 34.51 (EMR) and 34.81 (SSR) relays. Screw terminal and push-in terminal
Series - Timed socket for 34 series Features.68/.69 Slim timed sockets for 34 series, 6.2 mm wide Timer adjustment via top mounted rotary knob accessible after assembly Control signal terminal DIP-switch
More informationContactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationMoxa TCC-100/100I User s Guide
Moxa TCC-100/100I User s Guide Seventh Edition, June 2008 www.moxa.com/product 2008 Moxa Inc., all rights reserved. Reproduction without permission is prohibited. Moxa TCC-100/100I User s Guide The software
More informationChrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class
More informationABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
More informationAdvanced Data Capture and Control Systems
Advanced Data Capture and Control Systems Tronisoft Limited Email: sales@tronisoft.com Web: www.tronisoft.com RS232 To 3.3V TTL User Guide RS232 to 3.3V TTL Signal Converter Modules P/N: 9651 Document
More informationJ TB/TW Temperature limiter, temperature monitor
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationUser Guide. Westermo Teleindustri AB 6600-2204 TD-23. Leased Line V.23 Modem Multidrop applications. www.westermo.com
User Guide 6600-2204 TD-23 Westermo Teleindustri AB Leased Line V.23 Modem Multidrop applications www.westermo.com Legal information The contents of this document are provided as is. Except as required
More informationProduct Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
More informationThermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationGrounding Demystified
Grounding Demystified 3-1 Importance Of Grounding Techniques 45 40 35 30 25 20 15 10 5 0 Grounding 42% Case 22% Cable 18% Percent Used Filter 12% PCB 6% Grounding 42% Case Shield 22% Cable Shielding 18%
More informationRM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More information