1 LEVER TING DESIGN GS PPLINE PRESSURE REGULTOR S 6. and NSI Z21.18 Design ertified - 25-, 25-5 Maximum Inlet Pressure: NSI Z21.18 ertified - 25-, psi (140 mbar), 5 psi (45 mbar) Maxitrol-tested: all models...10 psi ( 690 mbar) With 1209 or 129: Max. inlet pressure (LP)...2 psi (140 mbar) Max. inlet pressure (natural)...5 psi (45 mbar) Emergency Exposure Limits ll models (inlet side only)...65 psi (4.5 bar) Maximum Individual Load Largest single appliance served by the regulator ,000 tu/hr ,000 tu/hr ,000 tu/hr apacity: Total load of all appliances combined 25- (/8, 1/2 )...150,000 tu/hr 25-5 (1/2, /4, 1 )...00,000 tu/hr 25-7 (1-1/4, 1-1/2 )...1,000,000 tu/hr mbient Temperature Limits ll models to 205 F (-40 to 96 ) DVGW...2 to 140 F (0 to 60 ) EN...5 to 176 F (-15 to 80 ) Vent Pipe onnection Size: /8" NPT /8" NPT /2" NPT Gases: Suitable for application in natural, manufactured, mixed gases, liquefied petroleum gases, and LP gas-air mixture piping systems. NOTE: ll Maxitrol gas appliance regulators must be installed and operated in accordance with Maxitrol's 'Safety Warning' bulletin. 25-*, 25-5*, 25-7 Pipe sizes from /8 to 1-1/2 * Design ertified - 25-, 25-5 Upright When vented to the outdoors the 25 Series is suitable for multi-poise mounting. When using the vent limiting device, the regulator (25-, 25-5) must be mounted in a horizontal upright position. Install the regulator properly with gas flowing as indicated by the arrow on the casting (also see the Safety Warning Instructions bulletin). 2008, Maxitrol ompany, ll Rights Reserved 1

2 Lever cting Design 25 series 25-*, 25-5* & 25-7 FETURES: Designed for multi-poise mounting... Self-aligning valve with lever action for dead end lockup... Durable, corrosion-resistant construction... High performance type for pounds to inches reduction... vailable in six pipe sizes from /8" to 1-1/2"... ENEFITS: Ease of installation... Longer life, less maintenance... May be used for both 2 psi and 5 psi corrugated stainless steel tubing (SST) systems. Precise regulation from pilot flows to full regulator capacity... Meets many utility specifications. The 25 Series is a pounds to inches regulator, meeting utility specifications. The 25 Series regulator is for use on residential, commercial, and industrial applications where adequate inlet pressures are available. They are a high performance type regulator and can be used as a single stage regulator - reducing pounds pressure to normal burner pressure. They can also be used as a line regulator on equipment already fitted with an appliance regulator. The 25- and 25-5 models are S certified and widely accepted with 2 psig and 5 psig house piping systems. In fact, the entire concept (using semi-rigid copper or flexible stainless steel tubing) would not have been possible without the development of the compact 25 series regulators. The 25-7, designed especially for the growing segment of electronic ignition equipment, permits the utilization of greater capacities without sacrificing performance. ll 25 Series models are also certified through DVGW to European EN 88. To deliver positive dead-end lock up, the 25 Series feature a high leverage valve linkage assembly. Lockup pressure can vary with the speed of the solenoid valve and its location. The regulators are capable of precise regulating control from full flow down to pilot flows. s an optional accessory, the 25- and 25-5 offer automatic vent limiting devices. The 1209 and 129 vent limiters eliminate the need to run vent piping to a safe area - in the event of a diaphragm rupture, gas escapement is limited to within the NSI/S standards level. NOTE: Vent limiters are designed for use indoors and in spaces where limiting the amount of gas escapement due to diaphragm failure is critical. Vent limiters are not to be used outdoors if they are exposed to the environment. 115 vent protector is available for outdoor use when vent protection is required. The 25 Series regulators are Maxitrol-tested for inlet pressures up to 10 psi (S certified for 2 psi and 5 psi). With the 1209 or 129 installed, maximum inlet pressure is 2 psi (LP) and 5 psi (natural). Inlet pressures exceeding 2 psi (LP), or 5 psi (natural) require a vent line. The self-aligning valve is made of nitrile rubber. Housings are durable aluminum die castings and all internal parts are carefully selected and corrosion resistant. The diaphragms are of high quality supported synthetic rubber compounds. The 25 Series regulators are suitable for multi-poise mounting. ut when using the vent limiting device, the regulator (25-, 25-5) must be mounted in a horizontal upright position. Install the regulator properly with gas flowing as indicated by the arrow on the casting. These regulators provide no downstream over-pressure protection in the event of failure. t supply pressures in excess of 2 psi they should not be used unless downstream appliance controls are rated for supply pressure or protected by some other means. onsult Maxitrol ompany for additional assistance. 2008, Maxitrol ompany, ll Rights Reserved 2 * S design certified

3 apacities and Pressure Drop PITIES - based on 1" w.c. pressure drop, from set point * sp gr gas expressed in FH (m /h). Model Number Outlet Pressure Set Point S Max. FH 1/2 psi (4 mbar) /4 psi (52 mbar) Operating Inlet Pressure 1 psi (69 mbar) 2 psi (18 mbar) 5 psi (45 mbar) 10 psi (690 mbar) 4.0 w.c (4.5) 190 (5.4) 220 (6.2) 220 (6.2) 00 (8.5) 20 (9.1) 25-* 25-5* w.c (.4) 150 (4.2) 180 (5.1) 220 (6.2) 290 (8.2) 20 (9.1) 10.0 w.c (2.8) 120 (.4) 150 (4.2) 220 (6.2) 280 (7.9) 20 (9.1) 4.0 w.c (8.5) 40 (9.6) 416 (11.8) 500 (14.2) 600 (17.0) 680 (19.) 7.0 w.c (6.9) 15 (8.9) 40 (9.6) 480 (1.6) 600 (17.0) 680 (19.) 10.0 w.c (6.4) 270 (7.6) 12 (8.8) 40 (12.2) 560 (15.9) 680 (19.) 4.0 w.c (19.0) 900 (25.5) 1050 (29.7) 1450 (41.1) 1750 (49.6) 2000 (56.6) 7.0 w.c (16.7) 760 (21.5) 900 (25.5) 1250 (5.4) 1750 (49.6) 2000 (56.6) 10.0 w.c (1.) 650 (18.4) 800 (22.7) 1250 (5.4) 1750 (49.6) 2000 (56.6) *NOTE: Maximum Individual Load: 25- is 100 FH (2.8 m /h), 25-5 is 250 FH (7.0 m /h), 25-7 is 900 FH (25.5 m /h) pproval based on use as an appliance regulator. PRESSURE DROP sp gr gas expressed in FH (m /h) (for system pressure drop calculations) Model 7.0 w.c. (17 mbar) 1/2 psi (4 mbar) /4 psi (52 mbar) 1 psi (69 mbar) 2 psi (18 mbar) (4.0) 204 (5.8) 250 (7.0) 289 (8.2) (9.6) 476 (1.5) 58 (16.5) 67 (19.1) (19.5) 972 (27.6) 1191 (.8) 175 (9.0) 1975 (55.9) Sizing Instructions Pressure Drop hart When 25 Series regulators are used on 2 psig piping systems - often times the 2 psig residential systems are sized with a 1-1/2 psi pressure drop through the copper or stainless steel tubing. This means there will be 2 psi at the inlet of the regulator under no flow conditions, and 1/2 psi at the regulator inlet under maximum flow conditions. To select a 25 series appliance regulator of ample flow - one must know: 1. vailable inlet pressure (maximum static/minimum operating). 2. Desired outlet pressure.. Required maximum flow rate. 4. Pipe size. Example: To select a 25 series regulator of ample capacity to handle flow... KNOWN: Desired flow rate 145 FH; pipe size 1/2"; operating inlet pressure 2 psi; outlet pressure 7" w.c.; lockup required. SOLUTION: heck pressure drop chart above - the 25-'s pressure drop at a flow rate of 145 FH is 7" w.c. - well below the available differential of 1.75 psi. The 25- (1/2") used with a 4" to 12" spring, set at 7", is the correct regulator to use for this application. Pressure Drop ( P) 2008, Maxitrol ompany, ll Rights Reserved

4 Dimensions and Spring Ranges DIMENSIONS - inches (millimeters) Model Number Pipe Size* Swing Radius all-outs 25- /8 x /8 1/2 x 1/2 (76) -1/2 (89) 4-1/4 (108) -7/8 (98) /2 x 1/2 /4 x /4 1 x 1 4-7/8 (124) 5-1/4 (1) 5-7/8 (149) 5-7/16 (18) /4 x 1-1/4 1-1/2 x 1-1/2 6-1/8 (156) 7-1/4 (184) 8 (20) 7 (178) * standard models NPT, 'M' models available with SP threads SPRING SELETION HRT - inches w.c. (mbar) unless noted Model Number S ertified 2 psi (18 mbar) 5 psi (45 mbar) Standard Spring Other Springs vailable ( ) 7-11 (17-27) 6-10 (15-25) 7-11 (17-27) 4 to 12 (10 to 0) 2-6 (5-15) (25-55) 15-0 (7-75) 1-2 psi (69-19) ( ) 7-11 (17-27) 6-10 (15-25) 7-11 (17-27) to 12 (10 to 0) 4 to 12 (10 to 0) 2-6 (5-15) 2-5 (5-12) (25-55) (25-55) 15-0 (7-75) 15-0 (7-75) 1-2 psi (69-19) (50-104) Maxitrol ompany 2555 Telegraph Rd., PO ox 220 Southfield, MI U.S.. 25LVR_MS_EN_ Replaced ulletin MS2055-0/ , Maxitrol ompany, ll Rights Reserved.

5 Lever cting Design Line Pressure Regulators S Design ertified Z21.80 / N 6.22 For 2-psi piping systems For applications from 2-psi to 5-psi, please see bulletin LPROPD_MS_EN. Maximum Inlet Pressure: S ertified... 2 psi (140 mbar) Minimum Inlet Pressure: S ertified... 1 psi (70 mbar) Emergency Exposure Limits: (inlet side only) psi (4.5 bar) Outlet Pressure Range: ertified spring inches w.c. Maximum Individual Load: Largest single appliance served by the regulator 25-L ,000 tu/hr 25-5L... 00,000 tu/hr 25-7L ,000 tu/hr apacity: Total load of all appliances combined 25-L (/8", 1/2") ,000 tu/hr 25-5L (1/2") ,000 tu/hr 25-5L (/4", 1") ,000 tu/hr 25-7L (1¼", 1½")... 1,000,000 tu/hr Venting: 25-L (optional 1209 vent limiter)...1/8" NPT 25-5L (optional 129 vent limiter)... /8" NPT 25-7L... 1/2" NPT Gases: Suitable for natural and liquefied petroleum gases. mbient Temperature Limits: -40 to 205 F (-40 to 96 ) Note: ll Maxitrol gas appliance regulators must be installed and operated in accordance with Maxitrol's 'Safety Warning' bulletin. 25-L, 25-5L, 25-7L Pipe sizes from /8" to 1½" Upright The 25 Series is suitable for multi-poise mounting. ut when using the vent limiting device, the regulator (25-L, 25-5L) must be mounted in a horizontal upright position. Install the regulator properly with gas flowing as indicated by the arrow on the casting (also see the Safety Warning Instructions bulletin). NOTE: Ventlimiters are designed for use indoors and in spaces where limiting the amount of gas escapement due to diaphragm failure is critical. Vent limiters should not be used outdoors if they are exposed to the environment. 115 vent protector is available for outdoor use when vent protection is required. 2008, Maxitrol ompany, ll Rights Reserved. 1

6 Lever cting Design 25 Series L-Model Line Pressure Regulators FETURES: Designed for multi-poise mounting... Self-aligning valve with lever action for dead end lockup... Durable, corrosion-resistant construction... High performance type for pounds to inches reduction... vailable in /8" to 1½" pipe sizes... ENEFITS: Ease of installation... Longer life, less maintenance... For use on 2-psi piping systems such as SST (corrugated stainless steel) or semi-rigid copper tubing... Precise regulation from pilot flows to full regulator capacity... Meets many utility specifications. The new line pressure regulator standard - NSI Z21.80 lthough Maxitrol's 25 Series are certified (NSI Z21.18) as appliance regulators (see bulletin 25LVR_MS_EN), in the past they have often been used as line pressure regulators. Until very recently, there was no standard for line pressure regulators. Z21.80 is the new NSI standard for line pressure regulators, intended for application in natural gas piping systems. Maxitrol's new 25 Series L-models are S certified (Z21.80) for 2-psi inlet pressure, with the 7 to 11 (inches w.c. outlet) spring. The L-models are lass 1, pounds to inches regulators, meeting utility specifications, for use on 2-psi piping systems such as SST (corrugated stainless steel) or semi-rigid copper tubing. The regulators are a high performance type - reducing pounds pressure to a level within the appliance's operating supply range. The line regulator is located upstream of equipment already fitted with an appliance regulator. The entire 2-psi system concept would not have been possible without the development of the compact 25 Series regulator. s optional accessories, the 25-L and 25-5L offer an automatic vent limiting device. The 1209 or 129 vent limiter eliminates the need to run vent piping to an outside area - in the event of a diaphragm rupture, gas escapement is limited to within the NSI standards level. The 25 Series are suitable for multi-poise mounting. ut when using a vent limiting device, the regulator must be mounted in a horizontal upright position. Install the regulator properly with gas flowing as indicated by the arrow on the casting. To deliver positive dead-end lock up, the 25 Series feature a high leverage valve linkage assembly. Lockup pressure can vary with the speed of the solenoid valve and its location. The regulators are capable of precise regulating control from full flow down to pilot flows. The self-aligning valve is made of nitrile rubber. Housings are durable aluminum die castings and all internal parts are carefully selected and corrosion resistant. The diaphragms are of high quality supported synthetic rubber compounds. The regulator is certified for inlet pressures up to 2 psi. Over-pressure protection is not required for supply pressures up to 2-psi. These regulators provide no downstream over-pressure protection in the event of failure. t supply pressures in excess of 2 psi, the new NSI Z21.80 line regulator standard requires means approved and tested with the regulator to limit the downstream pressure to 2-psi maximum, in the event of regulator failure. onsult Maxitrol ompany for assistance. Other 25 Series regulators will continue to be available as S certified appliance regulators, as well as noncertified models for up to 10-psi inlet pressure (see bulletin 25LVR_MS_EN). 2008, Maxitrol ompany, ll Rights Reserved. 2

7 apacities and Pressure Drop PITIES sp gr gas expressed in FH (m /h). Model Number Outlet Pressure Operating Inlet Pressure (pipe size) Set Point 1 psi (69 mbar) 1 1/2 psi (10 mbar) 2 psi (18 mbar) 25-L 7.0" w.c. 250 (7.1) 250 (7.1) 250 (7.1) (/8", 1/2") 10.0" w.c. 20 (6.5) 250 (7.1) 250 (7.1) 25-5L 7.0" w.c. 425 (12.0) 425 (12.0) 425 (12.0) (1/2") 10.0" w.c. 425 (12.0) 425 (12.0) 425 (12.0) 25-5L 7.0" w.c. 550 (15.6) 550 (15.6) 550 (15.6) (/4", 1") 10.0" w.c. 55 (15.1) 550 (15.6) 550 (15.6) 25-7L 7.0" w.c (28.) 1000 (28.) 1000 (28.) (1 1/4", 1 1/2") 10.0" w.c (28.) 1000 (28.) 1000 (28.) Maximum Individual Load: Largest single appliance served by the regulator 25-L...140,000 tu/hr 25-5L... 00,000 tu/hr 25-7L...900,000 tu/hr apacity: Total load of all appliances combined 25-L (/8", 1/2")...250,000 tu/hr 25-5L (1/2")...425,000 tu/hr 25-5L (/4", 1")...550,000 tu/hr 25-7L (1¼", 1½")...1,000,000 tu/hr PRESSURE DROP sp gr gas expressed in FH (m /h) Model Number 7.0" w.c. (17 mbar) 1/2 psi (4 mbar) /4 psi (52 mbar) 1 psi (69 mbar) 25-L 145 (4.0) 204 (5.8) 250 (7.0) 289 (8.2) 25-5L 8 (9.6) 476 (1.5) 58 (16.5) 67 (19.1) 25-7L 690 (19.5) 972 (27.6) 1191 (.8) 175 (9.0) Pressure Drop hart Pressure Drop ( P) mbar 1.8 Inches w.c. FH. m /hr Flow Rate 2008, Maxitrol ompany, ll Rights Reserved.

8 Dimensions and Spring Range 25-L 25-5L DIMENSIONS - inches (millimeters) Model Number Pipe Size* Swing all-outs Radius 25-7L 25-L /8 x /8 1/2 x 1/2 (76) 1/2 (89) 4 1/4 (108) 7/8 (98) 25-5L 1/2 x 1/2 /4 x /4 1 x 1 4 7/8 (124) 5 1/4 (1) 5 7/8 (149) 5 7/6 (18) 25-7L 1 1/4 x 1 1/4 1 1/2 x 1 1/2 6 1/8 (156) 7 1/4 (184) * standard models NPT threads. 'M' models available with ISO7 PL, 'MK' models ISO7 TR. Sizing Instructions 8 (20) 7 (178) Outlet Pressure Range (all models): ertified spring inches w.c. Frequently 2-psi piping systems are sized with a 1 psi pressure drop through the copper or stainless steel tubing. This means there will be 2 psi at the inlet of the regulator under no flow conditions, and 1 psi at the regulator inlet under maximum flow conditions. To select a line regulator of ample flow - one must know: 1. vailable inlet pressure (maximum static/minimum operating). 2. Desired outlet pressure.. Required maximum capacity (total load, all appliances combined),and maximum individual load. 4. Pipe size. Example: To select a line regulator of ample capacity to handle flow... KNOWN:. Required: 1/2" NPT line regulator, outlet pressure of 7" w.c., with a static pressure of 2-psi, and a minimum operating inlet pressure of 1 psi.. ombined tu rating of all appliances to be served by the regulator: 145,000 tu/hr.. Largest single appliance's tu rating: 90,000 tu/hr. SOLUTION:. In the apacities chart (page ), locate rows where 1/2" (pipe size) models with 7" w.c. outlet pressure - intersect with - 1 psi operating inlet pressure column. (25-L = 250 FH, 25-5L = 425 FH).. The total tu load requirement cannot exceed the equivalent FH result from step-. The combined 145,000 tu/hr requirement does not exceed either model's capacity.. The 90,000 tu/hr single largest appliance rating is below the 25-L maximum individual load capacity of 140,000 tu/hr. D. The 25-L is the smallest acceptable line regulator for this application. Maxitrol ompany 2555 Telegraph Rd., P.O. ox 220 Southfield, MI U.S.. 25LPR_MS_EN_ Replaced ulletin MS , Maxitrol ompany, ll Rights Reserved

9 Line Pressure Regulators and Over-Pressure Protection Devices For piping systems up to 5 psi S Design ertified Z21.80 / N 6.22 SYSTEM OMPONENTS Maximum Inlet Pressure: S ertified... 5 psi (45 mbar) ttention: Line pressure regulators with separate overpressure protection devices shall be factory preassembled, and supplied to the field as a unit. Emergency Exposure Limits: (inlet side only) psi (4.5 bar) Outlet Pressure Range: ertified spring inches w.c. Maximum Individual Load: Largest single appliance served (regulator with OPD) 25-L47 (/8, 1/2 ) (w/opd 47 attached) ,000 tu/hr 25-L48 (1/2 ) (w/opd 48 attached) ,000 tu/hr 25-5L48 (1/2 ) (w/opd 48 attached)... 25,000 tu/hr 25-5L48 (/4 ) (w/opd 48 attached)... 20,000 tu/hr 25-5L600 (/4 ) (w/opd 600 attached) ,000 tu/hr 25-5L600 (1 ) (w/opd 600 attached) ,000 tu/hr apacity: Total load of all appliances combined (regulator with OPD) 25-L47 (/8, 1/2 ) (w/opd 47 attached)...125,000 tu/hr 25-L48 (1/2 ) (w/opd 48 attached) ,000 tu/hr 25-5L48 (1/2 ) (w/opd 48 attached)... 25,000 tu/hr 25-5L48 (/4 ) (w/opd 48 attached)... 20,000 tu/hr 25-5L600 (/4 ) (w/opd 600 attached) ,000 tu/hr 25-5L600 (1 ) (w/opd 600 attached) ,000 tu/hr Venting: OPD integral vent limiting orifice w/dust cap OPD 48 (optional 1209 vent limiter)... 1/8 NPT OPD 600 (optional 1209 vent limiter)... 1/8 NPT Gases: Intended for application in natural gas piping systems up to 5 psi. mbient Temperature Limits: -40 to 205 F (0 to 96 ) Note: ll Maxitrol gas appliance regulators must be installed and operated in accordance with Maxitrol s Safety Warning bulletin. The 25 Series is suitable for limited horizontal mounting (less than or equal to 90 from upright). ut when using the vent limiting device, the regulator must be mounted in a horizontal upright position. Install the regulator properly Upright with gas flowing as indicated by the arrow on the casting (also see the Safety Warning Instructions bulletin). NOTE: Vent limiters are designed for use indoors and in spaces where limiting the amount of gas escapement due to diaphragm failure is critical. Vent limiters should not be used outdoors if they are exposed to the environment. 115 vent protector is available for outdoor use when vent protection is required Maxitrol ompany, ll Rights Reserved 1

10 FETURES S certified for up to 5-psi inlet pressure Over-pressure protection device (OPD) to limit downstream pressure in case of regulator failure Maxitrol OPD approved and tested with the regulator Self-aligning valve with lever action for dead end regulator lockup Optional vent limiter eliminates the need to run vent piping to an outside area ENEFITS Meets NSI standard Z21.80 for line pressure regulators for use on piping systems such as SST or semi-rigid copper tubing up to 5-psi OPD provides required downstream overpressure protection for supply pressures in excess of 2-psi Pounds to inches regulator provides precise control from pilot flows to full regulator capacity Meets many utility specifications THE NEW LINE PRESSURE REGULTOR STNDRD - NSI Z21.80 lthough Maxitrol s 25 Series are certified (NSI Z21.18) as appliance regulators (see bulletin 25LVR_MS_EN), in the past they have often been used as line pressure regulators. Until very recently, there was no standard for line pressure regulators. Z21.80 is the new NSI standard for line pressure regulators, intended for application in natural gas piping systems. s of May 1, 2002, S requires that all line pressure regulators above 2-psi must leave the factory pre-assembled and leak tested. t supply pressures in excess of 2-psi, the new line regulator standard requires a means (an over-pressure protection device / OPD) approved and tested with the regulator to limit the downstream pressure to 2-psi maximum, in the event of regulator failure. Line pressure regulators with separate overpressure protection devices shall be factory preassembled, and supplied to the field as a unit. Maxitrol-built OPDs provide the required downstream over-pressure protection. s optional accessories, the regulators and OPDs offer an automatic vent limiting device. The 1209 or 129 vent limiters eliminate the need to run vent piping to an outside area - in the event of a diaphragm rupture, gas escapement is limited to within the NSI standards level. The 25 Series are suitable for limited horizontal mounting (less than or equal to 90 from upright) - but when using a vent limiting device, the regulator must be mounted in a horizontal upright position for best performance. Install the regulator properly with gas flowing as indicated by the arrow on the casting. To deliver positive dead-end lock up, the 25 Series feature a high leverage valve linkage assembly. Lockup pressure can vary with the speed of the solenoid valve and its location. The regulators are capable of precise regulating control from full flow down to pilot flows. The self-aligning valve is made of nitrile rubber. Housings are durable aluminum die castings and all internal parts are carefully selected and corrosion resistant. The diaphragms are of high quality supported synthetic rubber compounds. The regulator with OPD is certified for inlet pressures up to 5-psi, and can withstand emergency exposure inlet pressure up to 65-psi. The regulator alone provides no downstream over-pressure protection in the event of failure. Other 25 Series regulators will continue to be available as S certified appliance regulators, as well as noncertified models for up to 10-psi inlet pressure (see bulletin 25LVR_MS_EN). NOTE: Immediately after installation and prior to operating any appliance: It is important to check the preassembled pipe connection between the regulator and OPD for leakage. Even though the Maxitrol 5 psi line regulator with OPD is shipped as an assembly, installation of the assembly can result in turning (tightening or loosening) of the preassembled connection. If gas leakage is detected, follow the same procedures to stop the leak as you would use with any field pipe connection, and repeat step number 5 according to the Safety Warning bulletin Maxitrol ompany, ll Rights Reserved 2

11 PITIES ND PRESSURE DROP- pplications above 2 psi, Regulator and OPD apacity: Total load of all appliances combined (regulator & OPD) 25-L47 (/8, 1/2 ) (w/opd 47) ,000 tu/hr 25-L48 (1/2 ) (w/opd 48) ,000 tu/hr 25-5L48 (1/2 ) (w/opd 48)... 25,000 tu/hr 25-5L48 (/4 ) (w/opd 48)... 20,000 tu/hr 25-5L600 (/4 ) (w/opd 600) ,000 tu/hr 25-5L600 (1 ) (w/opd 600) ,000 tu/hr Maximum Individual Load: Largest single appliance served (regulator & OPD) 25-L47 (/8, 1/2 ) (w/opd 47) ,000 tu/hr 25-L48 (1/2 ) (w/opd 48) ,000 tu/hr 25-5L48 (1/2 ) (w/opd 48)... 25,000 tu/hr 25-5L48 (/4 ) (w/opd 48)... 20,000 tu/hr 25-5L600 (/4 ) (w/opd 600) ,000 tu/hr 25-5L600 (1 ) (w/opd 600) ,000 tu/hr PRESSURE DROP HRT 2008 Maxitrol ompany, ll Rights Reserved

12 DIMENSIONS ND SPRING RNGE- pplications above 2 psi, Regulator and OPD 25-L47 ttention: Line pressure regulators with separate overpressure protection devices shall be factory preassembled, and supplied to the field as a unit. Dimensions - inches (millimeters) Model Number 25-L47 Pipe Size* /8 x /8 1/2 x 1/2 25-L48 1/2 x 1/2 25-5L L600 1/2 x 1/2 /4 x /4 /4 x /4 1 x 1 Swing Radius (76) (76) 4.4 (112) 4.4 (112) all Outs.5 (90).5 (90) 5. (15) 5.5 (140) 8 (20) 8.5 (216) 10 (254) 11 (279).9 (100).9 (100) 5.4 (140) 5.4 (140) 25-L48 * standard models NPT threads. 25-5L48 NOTE: Dimensions are to be used only as an aid in designing clearance for the regulator. ctual production dimensions may vary somewhat from those shown. Outlet Pressure Range (all models): ertified spring inches w.c. 25-5L600 SIZING INSTRUTIONS To select a line regulator of ample flow - one must know: 1. vailable inlet pressure (maximum static/minimum operating). 2. Desired outlet pressure.. Required maximum capacity (total load, all appliances combined), and maximum individual load. 4. Pipe size. Example: To select a line regulator with OPD of ample capacity to handle flow... KNOWN:. Required: 1/2 NPT line regulator with OPD, outlet pressure of 7 w.c., with a static pressure of 5-psi, and a minimum operating inlet pressure of /4 psi.. ombined tu rating of all appliances to be served by the regulator: 145,000 tu/hr.. Largest single appliance s tu rating: 90,000 tu/hr. SOLUTION:. In the apacities table (page ), locate [25-L47 (1/2 ) = 125 FH, 25-L48 (1/2 ) = 200 FH, 25-5L48 (1/2 ) = 25 FH].. The total tu load requirement cannot exceed the equivalent FH result from step-. The combined 145,000 tu/hr requirement exceeds the 25-L47 (1/2 ) capacity, but is less than that of the 25-L48 (1/2 ) and 25-5L48 (1/2 ).. The 90,000 tu/hr single largest appliance rating is below the 25-L48 maximum individual load capacity of 200,000 tu/hr. D. The 25-L48 is the smallest acceptable (1/2 ) line regulator with OPD for this application. Maxitrol ompany 2555 Telegraph Rd., PO ox 220 Southfield, MI LPROPD_MS_EN_ Replaced ulletin MS Maxitrol ompany ll Rights Reserved

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners M/MR Modulating Valves design certified For Atmospheric, Infrared, and Direct Fired urners TALE OF CONTENTS Description/Specifications... 1 Introduction... 2 Direct Fired Applications (Negative Pressure)...

More information

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications Instruction Manual Form 5753 Type HSR February 014 Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications P154 TYPE HSR ANGLE BODY P175 TYPE HSR STRAIGHT Figure 1.

More information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description Product Manual CVS Type 67AFR Filter Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS Type 67AFR

More information

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION

More information

Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology

Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology Vacuum Applications Vacuum regulators and breakers are widely used in process plants. Conventional regulators and relief valves might be suitable for service if applied correctly. This section provides

More information

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) VPS 504 S06 (120 VAC) is: CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter R-15 (Canada) UL

More information

1800C and 1800C-HC Series Service Regulators. Technical Bulletin

1800C and 1800C-HC Series Service Regulators. Technical Bulletin and -H Series Service Regulators Technical Bulletin and -H Series Service Regulators 0 Elster American Meter The Series pressure regulators are designed to control natural gas, air, nitrogen, carbon dioxide,

More information

1805 Series Relief Valves

1805 Series Relief Valves October 2011 1805 Series Relief Valves P1026 1805G Type 1805-2 Type 1805-4 Figure 1. Typical 1805 Relief Valves Introduction The 1805 Series relief valves are designed for use in farm tap applications

More information

MODEL 201 225LP 225LP2 225LP4 Safety Relief Valves

MODEL 201 225LP 225LP2 225LP4 Safety Relief Valves Edition GDRV.06 BRYAN DONKIN RMG CANADA LIMITED Serving the Gas Industry WORLDWIDE Applications Specifically designed to protect the downstream system or equipment from over pressure conditions by discharging

More information

Free Floating Lever Drain Traps For Loads to 50,000 lb/hr (22,679 kg/hr)...pressures to 1,000 psig (69 bar)

Free Floating Lever Drain Traps For Loads to 50,000 lb/hr (22,679 kg/hr)...pressures to 1,000 psig (69 bar) Free Floating ever rain Traps For oads to 50,000 lb/hr (22,679 kg/hr)...pressures to 1,000 psig (69 bar) iquid rainers Table -14. Maximum Operating Pressures for Handling ifferent Specific Gravity iquids

More information

167D Series Switching Valves

167D Series Switching Valves June 2011 167D Series Switching Valves P1185 P1184 167D TWO-WAY SWITCHING VALVE 167DA THREE-WAY SWITCHING VALVE Figure 1. 167D Series Switching Valves Introduction The 167D Series switching valves are

More information

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger

More information

Float and Thermostatic Traps Series H, C and X

Float and Thermostatic Traps Series H, C and X Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT

More information

Fittings, Tubing & Nipples

Fittings, Tubing & Nipples s, Tubing & Nipples P Series Pipe s s to 15,000 psi (1034 bar) Since 1945 Parker utoclave Engineers has designed and built premium quality valves, fittings and tubing. This commitment to engineering and

More information

Commercial & Industrial Propane Regulators and Meters

Commercial & Industrial Propane Regulators and Meters Commercial & Industrial Propane Regulators and Meters Master Distributor for First Stage Regulators P32* Field adjustable 60 Mesh screen on inlet 1/4 FNPT 250 PSI Excellent stability P37* Patented balance

More information

289 Series Spring-Loaded Relief Valves

289 Series Spring-Loaded Relief Valves October 14 89 Series Spring-Loaded Relief Valves W187_1 W1871 TYPE 89L 1 NPT TYPES 89H AND 89HH W187 NPT TYPE 89H W187_ TYPES 89U AND 89A Figure 1. Types 89H, 89L and 89U Relief Valves Introduction The

More information

REGULATORS D& HD Series

REGULATORS D& HD Series Watson McDaniel reserves the right to change the designs and/or materials of its products out notice. 2002 Watson McDaniel Company Ductile Iron body - HD Series Full port strainer & blowdown valve on pilot

More information

Fisher 377 Trip Valve

Fisher 377 Trip Valve 377 Trip Valve Product Bulletin Fisher 377 Trip Valve Fisher 377 pressure sensing trip valves are for control applications where a specific valve/actuator action is required when supply pressure falls

More information

NAVIEN AMERICA INC. 17855 FITCH AVENUE

NAVIEN AMERICA INC. 17855 FITCH AVENUE Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:

More information

Types 66R and 66RR Low-Pressure Relief Valves

Types 66R and 66RR Low-Pressure Relief Valves November 2009 Types 66R and 66RR Low-Pressure Relief Valves W1953 W1908 TYPE 66R RELIEF VALVE TYPE 66RR RELIEF VALVE Figure 1. Typical Constructions Introduction Types 66R and 66RR low-pressure throttling

More information

SIZING AND CAPACITIES OF GAS PIPING

SIZING AND CAPACITIES OF GAS PIPING APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING (This appendix is informative and is not part of the code.) A.1 General. To determine the size of piping used in a gas piping system, the following

More information

OBSOLETE. VS8420 Millivolt Gas Valve

OBSOLETE. VS8420 Millivolt Gas Valve APPLICATION The VS8420 Millivolt Gas Valve is compact and has a 60,000 Btuh capacity (1 in. pressure drop for straightthrough configuration). The design makes it ideal for fireplace and space heating applications.

More information

TYPE E Main Valve Sizes 3 /8 through 12

TYPE E Main Valve Sizes 3 /8 through 12 SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,

More information

SIZING AND CAPACITIES OF GAS PIPING (Not Adopted by the State of Oregon)

SIZING AND CAPACITIES OF GAS PIPING (Not Adopted by the State of Oregon) (IFGS) SIZING AND CAPACITIES OF GAS PIPING (Not Adopted by the State of Oregon) (This appendix is informative and is not part of the code. This appendix is an excerpt from the 2006 International Fuel Gas

More information

Flygt Ball Check Valves

Flygt Ball Check Valves 4/13 Supersedes: 6/96 The basic purpose of a check valve is to permit flow in one direction, prevent flow in the opposite direction and perform this function automatically and with minimum maintenance.

More information

OBSOLETE. VS8510,VS8520 Millivolt Gas Valve

OBSOLETE. VS8510,VS8520 Millivolt Gas Valve APPLICATION The VS8510, VS8520 Millivolt Gas Valve is compact and has a 60,000 Btuh capacity (1 in. pressure drop for straight through configuration). Its design makes it ideal for fireplace and space

More information

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled

More information

MFP14, MFP14S and MFP14SS Automatic Pumps

MFP14, MFP14S and MFP14SS Automatic Pumps Page 1 of 6 TI-P136-02 ST Issue 12 Cert. No. LRQ 0963008 ISO 9001, S and SS utomatic Pumps Description The Spirax Sarco automatic pump is a displacement receiver operated by steam or compressed air. It

More information

SQUARE D INDUSTRIAL CONTROL PRODUCTS

SQUARE D INDUSTRIAL CONTROL PRODUCTS SQUARE D INDUSTRIAL CONTROL PRODUCTS CLASS 9012 3a INDUSTRIAL PRESSURE SWITCHES Type A Heavy duty switch for virtually any industrial application involving air, water, steam or oil Bellows, piston and

More information

AIR LINE VALVES AND GAUGES

AIR LINE VALVES AND GAUGES AIR LINE VALVES AND GAUGES INGERSOLL-RAND AIR LINE VALVES AND GAUGES Maintaining consistent air pressure throughout the entire system is crucial for maximum performance and productivity. Ingersoll-Rand

More information

Rated Burst Pressure 200 Series: 2.5 : 1 H200 Series: 4 : 1

Rated Burst Pressure 200 Series: 2.5 : 1 H200 Series: 4 : 1 200 Series 0 to 3000 psig heck Valves H200 Series 0 to 6000 psig heck Valves Features & enefits Quick opening/positive closing Provides a wide range of adaptability Large flow capacity The patented sealing

More information

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features Pressure Reducing Valve Flow and leakage reduction Cavitation damage protection Throttling noise reduction Burst protection System maintenance savings The Pressure Reducing Valve is a hydraulically operated,

More information

WD600 STEAM TRAPS. Thermodynamic Steam Trap

WD600 STEAM TRAPS. Thermodynamic Steam Trap WD600 Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company WD600, WD600L Sizes 3/8, 1/2, 3/4, 1 NPT Material Stainless

More information

TECHNICAL DATA. Dry 122a. November 12, 2013

TECHNICAL DATA. Dry 122a. November 12, 2013 Dry 122a 1. PRODUCT DESCRIPTION The Viking is a quick-opening device. When installed with the required external Anti-flood Device, the assembly is designed to increase the operating speed of Viking Model

More information

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification... OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS INTRODUCTION...1 Scope...1 Description...1 Valve Identification...2 1.0 VALVE INSTALLATION...2 2.0 VALVE MAINTENANCE...3 Actuator Disassembly...3

More information

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP WILROY ATEX Approved HYDRAULICALLY ACTUATED DIAPHRAGM PUMP Williams and Milton Roy have combined technologies to design a pump blending the proven mroy hydraulic by-pass diaphragm design with the Williams

More information

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?

More information

SIZING AND CAPACITIES OF GAS PIPING

SIZING AND CAPACITIES OF GAS PIPING CALIFORNIA RESIDENTIAL CODE MATRIX ADOPTION TABLE APPENDIX A SIZING AND CAPACITIES OF GAS PIPING (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state

More information

CHAPTER II. This chapter contains a simplified description of the pipeline safety requirements. The complete text can be found in 49 CFR Part 192.

CHAPTER II. This chapter contains a simplified description of the pipeline safety requirements. The complete text can be found in 49 CFR Part 192. CHAPTER II REGULATOR AND RELIEF DEVICES This chapter contains a simplified description of the pipeline safety requirements. The complete text can be found in 49 CFR Part 192. BASIC CONCEPT In understanding

More information

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This

More information

series 5350 5351 Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN 12165 CW617N

series 5350 5351 Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN 12165 CW617N Pre-adjustable pressure reducing valves with self-contained cartridge - series CCREDITED ISO 9 FM ISO 9 No. CLEFFI / GB replaces / GB Function Pressure reducing valves are devices which, when installed

More information

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller BLZPTS-1 NOVEMBER 19, 2013 TS350 TS752 BLPS PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller DESCRIPTION The BLPS, TS350

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS 36C01 Combination Gas Valves (24 Volt and 120 Volt Models) INSTALLATI INSTRUCTIS FAILURE TO READ AND FOLLOW ALL INSTRUCTIS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CTROL COULD CAUSE

More information

G234X-55 Conventional Gas Boiler

G234X-55 Conventional Gas Boiler Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus G234X-55 fl oor standing hot water boiler(s), suitable with natural

More information

Automatic Control Valves WATTS EU 100 Series

Automatic Control Valves WATTS EU 100 Series utomatic ontrol Valves WTTS U Series The Watts Industries range of automatic control valves consist of a hydraulically operated valve, which is controlled by a pilot circuit. The main valve (U ) is the

More information

ASME/ANSI B16.1-1998 - Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B16.3-1998 - Malleable Iron Threaded Fittings ASME/ANSI B16.

ASME/ANSI B16.1-1998 - Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B16.3-1998 - Malleable Iron Threaded Fittings ASME/ANSI B16. ASME/ANSI B16.1-1998 - Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B16.3-1998 - Malleable Iron Threaded Fittings ASME/ANSI B16.4-1998 - Cast Iron Threaded Fittings ASME/ANSI B16.5-1996 - Pipe

More information

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features Pressure Relief/Sustaining Valve Prioritizing pressure zones Ensuring controlled pipeline fill-up Preventing pipeline emptying Pump overload & cavitation protection Safeguarding pump minimum flow Excessive

More information

Pressure Switch for gas and air

Pressure Switch for gas and air Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth

More information

Gas Line Sizing. Z Maximum gas demand shall be determined by adding all of the equipment Btu ratings from appliances connected on the system.

Gas Line Sizing. Z Maximum gas demand shall be determined by adding all of the equipment Btu ratings from appliances connected on the system. Gas Line Sizing When sizing Gas piping systems certain factors must be considered. They are: Z It shall provide sufficient gas to meet the maximum demand of the gas equipment. Piping must be sized to supply

More information

Fisher 377 Trip Valve

Fisher 377 Trip Valve Instruction Manual Fisher 377 Trip Valve Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 2 Educational Services... 2 Installation... 4 Supply Pressure Requirements...

More information

SPERRYN GAS CONTROLS DELTA FLUID PRODUCTS LIMITED

SPERRYN GAS CONTROLS DELTA FLUID PRODUCTS LIMITED SPERRYN GAS CONTROLS DELTA FLUID PRODUCTS LIMITED Domestic and Non-Domestic Meter Regulators G940/G941 - Domestic Meter Regulator Domestic regulator offering high performance in a compact unit. Sizes:

More information

APCO SLOW CLOSING AIR/VACUUM VALVES

APCO SLOW CLOSING AIR/VACUUM VALVES BULLETIN 1 JULY 01 APCO SLOW CLOSING AIR/VACUUM VALVES Series 1900 APCO Slow Closing Air/Vacuum s Maximum Air Flow Velocity in Good Pipeline Design The Air/Vacuum operates in the normal fashion allowing

More information

SELECTION, APPLICATION AND MAINTENANCE

SELECTION, APPLICATION AND MAINTENANCE DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine

More information

BULLETIN 70.00-1 OCTOBER 2012. DeZURIK ROTARY DIAPHRAGM ACTUATORS

BULLETIN 70.00-1 OCTOBER 2012. DeZURIK ROTARY DIAPHRAGM ACTUATORS BULLETIN 70.00-1 OCTOBER 2012 DeZURIK ROTARY DIAPHRAGM ACTUATORS 2 2012 DeZURIK, Inc. Design & Construction DeZURIK rotary diaphragm actuators are available for use on rotary control valves including:

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...

More information

FRL/AirCare Air Controls & Accessories

FRL/AirCare Air Controls & Accessories FRL/irare ir ontrols & ccessories Lincoln Regulators, Filters & Lubricators well-planned compressed air system ensures minimum pressure loss in the system, and the removal of contaminants: water, compressor

More information

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS INTRODUCTION Rupture discs are often used as primary pressure relief devices and to isolate pressure relief valves. When used as a primary pressure relief

More information

Tubing Data. Contents. Tubing Selection. Tubing Handling. Tubing Material. Tubing Outside Diameter Hardness. Tubing Wall Thickness

Tubing Data. Contents. Tubing Selection. Tubing Handling. Tubing Material. Tubing Outside Diameter Hardness. Tubing Wall Thickness www.swagelok.com Tubing Data Contents Tubing Selection... 1 Tubing Handling.... 1 Gas Service... 2 Tubing Installation.... 2 Suggested Allowable Working Pressure Tables Carbon Steel Tubing... 3 Stainless

More information

Type 119 Control Valve

Type 119 Control Valve Instruction Manual Form 5204 Type 119 December 2009 Type 119 Control Valve Introduction Scope of the Manual This instruction manual provides installation, spring adjustment, maintenance, and parts information

More information

Side-Trak 830/840. Process Gas Mass Flow Meters and Controllers. www.sierrainstruments.com

Side-Trak 830/840. Process Gas Mass Flow Meters and Controllers. www.sierrainstruments.com Process Gas Mass Flow Meters and Controllers Features n Direct monitoring of mass flow eliminates need for ancillary pressure and temperature sensing n Patented straight sensor tube with access ports permits

More information

Model 4418F. www.amot.com. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Model 4418F. www.amot.com. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve High Pressure Control Valve Model 4418F Overview The 4418F has been designed specifically for use as an air start valve for diesel engines or as a fuel shut-off valve for gas turbine applications. Its

More information

Thermostatic valve Type AVTA

Thermostatic valve Type AVTA MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The

More information

Type 92S Pilot-Operated Steam Regulator

Type 92S Pilot-Operated Steam Regulator Type 92S Pilot-Operated Steam Regulator Introduction The Type 92S steam regulator is piston actuated for high cycle steam service which includes a Type 6492L, 6492H or pilot (see Figure 1). These pilots

More information

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC) APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines

More information

Baumann 24003 3 Way Bronze or Stainless Steel Control Valve

Baumann 24003 3 Way Bronze or Stainless Steel Control Valve Product Bulletin D1039X012 24003 Valve Baumann 24003 3 Way Bronze or Stainless Steel Control Valve 3 Way Rugged Industrial Control Valve For Mixing and Diverting Applications The Baumann 24003 3 way control

More information

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation Instruction Manual 1052 Size 20 Actuator (F & G) Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation Contents Introduction... 1 Scope of manual... 1 Description... 1 Specifications...

More information

3/2-way Mini Solenoid Valve

3/2-way Mini Solenoid Valve 3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug

More information

Fisher 2625, 2625SST, and 2625NS Volume Boosters

Fisher 2625, 2625SST, and 2625NS Volume Boosters Instruction Manual 2625, 2625SST, and 2625NS Volume Booster Fisher 2625, 2625SST, and 2625NS Volume Boosters Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 2 Educational

More information

Thermostatic expansion valves type TR6 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Thermostatic expansion valves type TR6 REFRIGERATION AND AIR CONDITIONING. Technical leaflet Thermostatic expansion valves type REFRIGERATION AND AIR CONDITIONING Technical leaflet Thermostatic expansion valves, type Contents Page Introduction........................................................................................3

More information

Automatic Bypass Control AVDO

Automatic Bypass Control AVDO Application AVDO is a self-acting constant flow control primarily used either to maintain minimum flow rates through e.g. a low-capacity gas boiler or to control the differential pressure in a central

More information

Type 99 Pressure Reducing Regulator

Type 99 Pressure Reducing Regulator Instruction Manual Form 589 Type 99 February 2016 Type 99 Pressure Reducing Regulator! WARNINg Since a pilot-operated regulator is constructed of both a pilot and a main valve, care should be used not

More information

POWERS Controls No. 4 Pneumatic Damper Actuator

POWERS Controls No. 4 Pneumatic Damper Actuator POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000

More information

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented / Unattended Type

More information

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9 Pumping Systems, Intensifiers, Gas Boosters and High Pressure Generators High Pressure Equipment Company produces a number of components and systems for general industrial, elevated pressure applications.

More information

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications May 2016 W8962 Figure 1. Type EZL Pressure Reducing Regulator Features Main Diaphragm The main diaphragm is Nitrile (NBR)

More information

API Flanged Safety Relief Valves Series 526 CATALOG

API Flanged Safety Relief Valves Series 526 CATALOG API Flanged Safety Relief Valves Series 26 CATALOG The-Safety-Valve.com 1 Valve finder How to find the right product group High operating to set pressure ratio, high backpressure or low total height? Yes

More information

Type 99 Pressure Reducing Regulator

Type 99 Pressure Reducing Regulator Bulletin 7: February 2016 Type Pressure Reducing Regulator W27 W76 Figure 1. Typical Type Regulator Introduction The Type gas regulators provide a broad capacity for controlled pressure ranges and capacities

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

G670 Intermittent Pilot Ignition Controls

G670 Intermittent Pilot Ignition Controls Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin Issue Date 0300 Intermittent Pilot Ignition Controls Figure 1: Intermittent Pilot Ignition Control

More information

Type 3510-1 and Type 3510-7 Pneumatic Control Valves Type 3510 Micro-flow Valve

Type 3510-1 and Type 3510-7 Pneumatic Control Valves Type 3510 Micro-flow Valve Type 3510-1 and Type 3510-7 Pneumatic Control Valves Type 3510 Micro-flow Valve ANSI version Application Control valve especially designed for controlling low flow rates in pilot plants and technical research

More information

REGULATORS 175/153 Series

REGULATORS 175/153 Series 175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially

More information

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing 408-409

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing 408-409 Engineering Data Table of Contents Page No. I II Formulas, Conversions & Guidelines Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Sizing 408-409 Steam

More information

DV-5 Deluge Valve with Remote-Resetting, Pressure-Reducing Trim 4 Inch and 6 Inch (DN100 and DN150) General Description.

DV-5 Deluge Valve with Remote-Resetting, Pressure-Reducing Trim 4 Inch and 6 Inch (DN100 and DN150) General Description. Worldwide Contacts www.tyco-fire.com DV-5 Deluge Valve with Trim 4 Inch and 6 Inch (DN and DN5) General Description The TYCO DV-5 Deluge Valve with Trim is a diaphragm-style valve that depends upon water

More information

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description Worldwide Contacts www.tyco-fire.com Model F thru F3 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description The Mulsifyre Nozzles are open (nonautomatic) nozzles and they are designed

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in cooling California NOx

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS VGBQ SERIES CONVERSION KIT VIKING RANGE CORPORATION 111 Front Street Greenwood, Mississippi (MS) 38930 USA (662) 455-1200 IMPORTANT: PLEASE READ AND FOLLOW 1. Before beginning,

More information

Electronic Wallmount Faucet 1500T4 & 1501T4 Series

Electronic Wallmount Faucet 1500T4 & 1501T4 Series Electronic Wallmount Faucet 1500T4 & 1501T4 Series Specification: (example) Battery (4 C cell) or Hardwire (24 VAC) infrared electronic handwash system H 2OPTICS technology no external adjustments required

More information

High Pressure Equipment High Pressure Valves, Fittings and Tubing

High Pressure Equipment High Pressure Valves, Fittings and Tubing igh quipment igh Valves, ittings and Tubing 0,000, 40,000 and psi service igh quipment Company has developed a line of igh products to assure safe and easy plumbing for 0,000, 40,000 and psi. These needle

More information

VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)

VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01) VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,

More information

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure MAKING MODERN LIVING POSSIBLE Thermostatic valve AVTA Technical brochure 2 IC.PD.500.A3.02-520B3728 Danfoss A/S 07-2009/ RA-MC/mr Contents Page Features............................................................................................4

More information

NFPA31FuelOilPiping 1 Revised 3-1-11

NFPA31FuelOilPiping 1 Revised 3-1-11 NFPA 31 Fuel Oil Piping, Installation and Testing Chapter 8 Fuel Piping Systems and Components 8.1 Scope. This chapter shall apply to piping systems and their components used to transfer fuel oil from

More information

Shut-off & Lockout Valves 1/4" to 1-1/2" port size

Shut-off & Lockout Valves 1/4 to 1-1/2 port size Section 16 Shut-off & Lockout Valves 1/4" to 1-1/2" port size Contents T72 Excelon Shut-off & Lockout Valves 1/4", 3/8" Port Sizes....................................ALE-16-2 T73 Excelon Shut-Off & Lockout

More information

VALVES FOR REFRIGERATING SYSTEMS

VALVES FOR REFRIGERATING SYSTEMS VALVES FOR REFRIGERATING SYSTEMS FROM QUALITY OUR NATURAL DEVELOPMENT Achieved the goal of fi fty years working in the industry of Refrigeration and Air Conditioning, Castel Quality Range of Products is

More information

Fig B36 Stainless Steel 'T' Type or Basket Type Strainers

Fig B36 Stainless Steel 'T' Type or Basket Type Strainers Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Welding Reels HANNAY REELS. For use for: Arc Welding Gas Welding Cutting Operations H-9422-W Rev. 5. The reel leader.

Welding Reels HANNAY REELS. For use for: Arc Welding Gas Welding Cutting Operations H-9422-W Rev. 5. The reel leader. Welding Reels HANNAY REELS For use for: The reel leader. Arc Welding Gas Welding Cutting Operations H-9422-W Rev. 5 Series SWCR/WCR Arc Welding Reels: Power or Manual Rewind To handle cable to 400 amps.

More information