Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace FREEDOM 80 TDD-D-1 PUB. NO
|
|
- Laureen Osborne
- 7 years ago
- Views:
Transcription
1 Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace FREEDOM 80 TDD-D- AUDA00A92A, AUDA00A930A, AUDA060A92A, AUDA060A936A, AUDB060A936A, AUDB080A92A, AUDB080A936A, AUDB080A98A, AUDC080A960A, AUDB00A936A, AUDB00A95A, AUDC00A98A, AUDC00A960A, AUDD00A972A, AUDCA95A, AUDDA960A, AUDD0A960A Single-Stage Fan Assisted Combustion System PUB. NO
2 General Features NATURAL GAS MODELS Central Heating furnace designs are certified by the American and Canadian Gas Associations for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. SAFE OPERATION The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide extra safety. QUICK HEATING Durable, cycle tested, heavy gauge aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure. BURNERS burners will give years of quiet and efficient service. All models can be converted to L.P. gas. INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connection points for E.A.C./humidifier. AIR DELIVERY The -speed, direct drive blower motor, has sufficient airflow for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed. STYLING Heavy gauge steel and wrap-around cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass. FEATURES AND GENERAL OPERATION The FREEDOM 80 High Efficiency Gas Furnaces empoys an adaptive Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access. a. Low energy power venter b. Vent proving pressure switch. 08 American Standard Heating & Air Conditioning 2 Pub
3 Contents General Features 2 Features and Benefits Standard Equipment Optional Equipment General Data 5 AUDA00A92A 5 AUDA00A930A 5 AUDA060A92A 6 AUDA060A936A 6 AUDB060A936A 6 AUDB080A92A 7 AUDB080A936A 7 AUDB080A98A 7 AUDC080A960A 7 AUDB00A936A 8 AUDB00A95A 8 AUDC00A98A 8 AUDC00A960A 8 AUDD00A972A 9 AUDCA95A 9 AUDDA960A 9 AUDD0A960A 9 Performance Data 0 Field Wiring 2 Dimensions Electrical Data 5 Pub
4 Features and Benefits Power supply Multi-port In-shot burners Integrated solid state control with self diagnostics Silicon Nitride hot surface igniter with adaptive heat up Complete front service access Heavy guage aluminized steel heat exchanger Slide out blower assembly Blower door safety switch Direct drive, -speed motor Optional L.P. conversion kit Common vent Alternate bottom/left/right return air Hinged blower door Perfect Fit door latches FREEDOM 80 UPFLOW/HORIZONTAL RIGHT or LEFT STANDARD EQUIPMENT Gasketed blower door Single wire twinning Selectable cooling fan off delay Left-right gas connection Optional L.P. conversion kit Common vent capability 2 volt fuse Manual reset flame roll out switches Insulated blower door Insulated blower compartment Accessory hook-up capability - Hum and EAC Blower door safety switch n-prorated -year heat exchanger limited warranty 5-year limited parts warranty FREEDOM 80 OPTIONAL EQUIPMENT Thermostat... BAYSTAT388 [ ] Thermostat, Heating/Cooling Single Stage (Mounts Horizontally)... AY28X092 [ ] Thermostat, Heating/Cooling Single Stage (Mounts Vertically)... BAYSTAT305 [ ] Thermostat, Electronic Programmable -Stage Heating/-Stage Cooling... TAYSTAT300C [ ] Propane Conversion Kit... BAYLPKTA [ ] Electronic Air Filter, Perfect Fit Super Efficiency (-" Wide Gas Furnace)... TFE5A9FR [ ] Electronic Air Filter, Perfect Fit Super Efficiency (7-" Wide Gas Furnace)... TFE75A9FR [ ] Electronic Air Filter, Perfect Fit Super Efficiency (2" Wide Gas Furnace)... TFEA9FR [ ] Electronic Air Filter, Perfect Fit Super Efficiency (2-" Wide Gas Furnace)... TFE25A9FR [ ] Electronic Air Filter, Perfect Fit High Efficiency (-" Wide Gas Furnace)... TFM5A9FR [ ] Electronic Air Filter, Perfect Fit High Efficiency (7-" Wide Gas Furnace)... TFM75A9FR [ ] Electronic Air Filter, Perfect Fit High Efficiency (2" Wide Gas Furnace)... TFMA9FR [ ] Electronic Air Filter, Perfect Fit High Efficiency (2-" Wide Gas Furnace)... TFM25A9FR [ ] Electronic Air Filter, Perfect Fit Standard Efficiency (7-" Wide Gas Furnace)... TFP75A9FR0 [ ] Electronic Air Filter, Perfect Fit Standard Efficiency (2" Wide Gas Furnace)... TFPA9FR0 [ ] Electronic Air Filter, Perfect Fit Standard Efficiency (2-" Wide Gas Furnace)... TFP25A9FR0 [ ] Coil Enclosure (-" Wide Cabinets)... BAYCLE00C [ ] Coil Enclosure (7-" Wide Cabinets)... BAYCLE700C [ ] Coil Enclosure (2" Wide Cabinets)... BAYCLE0C [ ] Coil Enclosure (2-" Wide Cabinets)... BAYCLE0C [ ] High Altitude Pressure Switch Kit... BAYHALT28 [ ] Masonry Chimney Vent Kit... BAYVENT800B [ ] Filter Rack Kit... BAYRACK960A [ ] Pub
5 General Data PRODUCT SPECIFICATIONS MODEL TYPE RATINGS 2 Input BTUH Capacity BTUH (ICS) 3 AFUE Temp. rise (Min.-Max.) F. BLOWER DRIVE Diameter - Width (In.). Used Speeds (.) CFM vs. in. w.g. Motor HP R.P.M. COMBUSTION FAN - Type Drive -. Speeds Motor HP - RPM FLA FILTER Furnished? Type Recommended Hi Vel. (.-Size-Thk.) VENT Size (in.) HEAT EXCHANGER Type-Fired -Unfired Gauge (Fired) ORIFICES Main Nat. Gas. Qty. Drill Size L.P. Gas Qty. Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS Type Number POWER CONN. V / Ph / Hz Ampacity (In Amps) Max Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) AUDA00A92A 0,000 32,000 0 x 6 /5 080 Direct - / x25 - in. Round / x 6- x 30-9 / 0 AUDA060A92A 60,000 7, x 6 /5 080 Direct - / x25 - in. Round / x 6- x 30-2 / 5 AUDA00A930A 0,000 32,000 0 x 6 /3 075 Direct - / x25 - in. Round / x 6- x / 3 Central Furnace heating designs are certified by AGA and CSA. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate % per,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to,500 feet, derate % per,000 feet for elevations above,500 feet above sea level. 3 Based on U.S. government standard tests. The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. Pub
6 General Data PRODUCT SPECIFICATIONS MODEL TYPE RATINGS 2 Input BTUH Capacity BTUH (ICS) 3 AFUE Temp. rise (Min.-Max.) F. BLOWER DRIVE Diameter - Width (In.). Used Speeds (.) CFM vs. in. w.g. Motor HP R.P.M. COMBUSTION FAN - Type Drive -. Speeds Motor HP - RPM FLA FILTER Furnished? Type Recommended Hi Vel. (.-Size-Thk.) VENT Size (in.) HEAT EXCHANGER Type-Fired -Unfired Gauge (Fired) ORIFICES Main Nat. Gas. Qty. Drill Size L.P. Gas Qty. Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS Type Number POWER CONN. V / Ph / Hz Ampacity (In Amps) Max Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) AUDA060A936A 60,000 7,000 0 x 6 /3 075 Direct - / x25 - in. Round / x 6- x / 8 AUDB060A936A 60,000 7,000 0 x 7 /3 075 Direct - / x25 - in. Round / x 9- x / 27 AUDB080A92A 80,000 6, x 7 /5 080 Direct - / x25 - in. Round / x 9- x / 29 Central Furnace heating designs are certified by AGA and CSA. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate % per,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to,500 feet, derate % per,000 feet for elevations above,500 feet above sea level. 3 Based on U.S. government standard tests. The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 6 Pub
7 General Data PRODUCT SPECIFICATIONS MODEL TYPE RATINGS 2 Input BTUH Capacity BTUH (ICS) 3 AFUE Temp. rise (Min.-Max.) F. BLOWER DRIVE Diameter - Width (In.). Used Speeds (.) CFM vs. in. w.g. Motor HP R.P.M. COMBUSTION FAN - Type Drive -. Speeds Motor HP - RPM FLA FILTER Furnished? Type Recommended Hi Vel. (.-Size-Thk.) VENT Size (in.) HEAT EXCHANGER Type-Fired -Unfired Gauge (Fired) ORIFICES Main Nat. Gas. Qty. Drill Size L.P. Gas Qty. Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS Type Number POWER CONN. V / Ph / Hz Ampacity (In Amps) Max Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) AUDB080A936A 80,000 63,000 0 x 7 /3 075 Direct - / x25 - in. Round / x 9- x 30-2 / 32 AUDB080A98A 80,000 6,000 0 x 8 /3 075 Direct - / x25 - in. Round / x 9- x 30-2 / 32 AUDC080A960A 80,000 6, x0 3/ 00 Direct - / x25 - in. Round / x 23 x / 5 C Pub
8 General Data PRODUCT SPECIFICATIONS MODEL TYPE RATINGS 2 Input BTUH Capacity BTUH (ICS) 3 AFUE Temp. rise (Min.-Max.) F. BLOWER DRIVE Diameter - Width (In.). Used Speeds (.) CFM vs. in. w.g. Motor HP R.P.M. COMBUSTION FAN - Type Drive -. Speeds Motor HP - RPM FLA FILTER Furnished? Type Recommended Hi Vel. (.-Size-Thk.) VENT Size (in.) HEAT EXCHANGER Type-Fired -Unfired Gauge (Fired) ORIFICES Main Nat. Gas. Qty. Drill Size L.P. Gas Qty. Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS Type Number POWER CONN. V / Ph / Hz Ampacity (In Amps) Max Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) AUDB00A936A 00,000 79, x 7 /3 075 Direct - / x25 - in. Round / x 9- x 30-5 / AUDB00A95A 00,000 79, x 8 /3 075 Direct - / x25 - in. Round / x 9- x / 3 AUDC00A98A 00,000 79, x Direct - / x25 - in. Round / x 23 x / 5 AUDC00A960A 00,000 79,000 x Direct - / x25 - in. Round / x 23 x / 5 Central Furnace heating designs are certified by AGA and CSA. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate % per,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to,500 feet, derate % per,000 feet for elevations above,500 feet above sea level. 3 Based on U.S. government standard tests. The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 8 Pub
9 General Data PRODUCT SPECIFICATIONS MODEL TYPE RATINGS 2 Input BTUH Capacity BTUH (ICS) 3 AFUE Temp. rise (Min.-Max.) F. BLOWER DRIVE Diameter - Width (In.). Used Speeds (.) CFM vs. in. w.g. Motor HP R.P.M. COMBUSTION FAN - Type Drive -. Speeds Motor HP - RPM FLA FILTER Furnished? Type Recommended Hi Vel. (.-Size-Thk.) VENT Size (in.) HEAT EXCHANGER Type-Fired -Unfired Gauge (Fired) ORIFICES Main Nat. Gas. Qty. Drill Size L.P. Gas Qty. Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS Type Number POWER CONN. V / Ph / Hz Ampacity (In Amps) Max Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) AUDD00A972A 00, x 0 3/ 00 Direct - / x25 - in. Round / x 26- x / 63 AUDCA95A,000 96, x Direct - / x25 - in. Round / x 23 x / 6 AUDDA960A,000 96,000 x Direct - / x25 - in. Round / x 26- x / 7 AUDD0A960A 0,000, x 0 3/ 075 Direct - / x25 - in. Round / x 26- x / 8 Central Furnace heating designs are certified by AGA and CSA. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate % per,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to,500 feet, derate % per,000 feet for elevations above,500 feet above sea level. 3 Based on U.S. government standard tests. The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. Pub
10 Performance Data FURNACE AIRFLOW (CFM) VS. STATIC PRESSURE (ins. w.g.) MODEL SPEED TAP AUDA00A92A - HIGH - Black AUDA00A930A - HIGH - Black AUDA060A92A - HIGH - Black AUDA060A936A - HIGH - Black AUDB060A936A - HIGH - Black AUDB080A92A - HIGH - Black AUDB080A936A - HIGH - Black AUDB080A98A - HIGH - Black AUDC080A960A - HIGH - Black AUDB00A936A - HIGH - Black AUDB00A95A - HIGH - Black AUDC00A98A - HIGH - Black AUDC00A960A - HIGH - Black Pub
11 Performance Data FURNACE AIRFLOW (CFM) VS. STATIC PRESSURE (ins. w.g.) MODEL SPEED TAP AUDD00A972A BOTTOM AND LEFT SIDE RETURN - HIGH - Black AUDD00A972A - HIGH - Black AUDCA95A - HIGH - Black AUDDA960A - HIGH - Black AUDD0A960A - HIGH - Black SEE NOTE te : High speed CFM is based on bottom and left side return option for this model. Medium High, Medium Low, and Low speedtaps for this model do not have improved airflow with the addition of side return. CFM VS. TEMPERATURE RISE MODEL Cubic Feet Per Minute (CFM) AUDA00A92A AUDA00A930A AUDA060A92A AUDA060A936A AUDB060A936A AUDB080A92A AUDB080A936A AUDB080A98A AUDC080A960A AUDB00A936A AUDB00A95A AUDC00A98A AUDC00A960A AUDD00A972A AUDCA95A AUDDA960A AUDD0A960A Pub
12 Field Wiring FIELD WIRING DIAGRAM FOR HEATING ONLY FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) From Dwg.. 2B337 Rev. From Dwg.. 2B336 Rev. 2 Pub
13 Field Wiring From Dwg.. 2B322 Rev. From Dwg.. 2B323 Rev. Pub
14 Dimensions AUD OUTLINE DRAWING (ALL DIMENSIONS ARE IN INCHES) MODEL DIM "A" DIM "B" DIM "C" DIM "D" AUDA00C92A AUDA00C930A AUDA060C92A AUDA060C936A AUDB060A936A AUDB080C92A AUDB080C936A AUDB080C98A AUDB00C936A AUDB00C95A AUDC080C960A AUDC00C98A AUDC00C960A AUDCC95A AUDD00C972A AUDDC960A AUDD0C960A -" 9-5/8" 3-/" 3" 7-" 9-5/8" 6-/" 6" 2" 3-/6" 9-3/" 9-" 2-" 5-5/6" 23-/" 23" Pub
15 Electrical Data WIRING DIAGRAM FOR GAS FURNACES Pub
16 SCHEMATIC DIAGRAM FOR GAS FURNACES American Standard Heating & Air Conditioning 60 Troup Highway Tyler, TX For more information contact your local dealer (distributor) File. PL-UN-FURN-TDD-D- 3/98 P.I. Supersedes TDD-D- 8/95 American Standard Heating & Arir Conditioning has a policy of continuous product and product data improvement, it reserves the right to change design and specifications without notice.
XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE
UPF/HORIZONTAL 2-, VARIABLE SPEED GAS-FIRED FURNACE XV80 MODELS TUD2B060A9V3VB, TUD2B080A9V3VB TUD2C080A9V4VB, TUD2C080B9V4VB TUD2B00A9V3VB, TUD2C00A9V5VB TUD2C00B9V5VB, TUD2DA9V5VB TUD2DB9V5VB, TUD2DA9V5VB
More informationXV 95. Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace PUB. NO.
Upflow/ Horizontal Left, Downflow/ Horizontal Right Speed Two Stage Condensing Gas-Fired Furnace XV 95 TUH2B060A9V3VB TUH2B080A9V3VB TUH2B080A9V4VB TUH2C100A9V4VB TUH2C100A9V5VB TUH2D120A9V5VB Direct Vent
More informationCommercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
More informationM7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace
TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially
More informationCooling Capacity CFM range @.5 in. w.c. (125 Pa)
N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air
More informationCooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in cooling California NOx
More informationCooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in
More informationF9MXE. Product Specifications
96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Select models earn the ENERGY STAR (See below, indicated with check mark.) Xtra SEER ECM blower motor Supports
More informationGas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard
LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled
More informationG9MXE. Product Specifications
Up to 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL Up to 96% AFUE, all models all positions California NOx approved Select models earn the ENERGY STAR (See below, indicated with check mark.)
More informationTECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES
TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S NATURAL GAS 40-130 MBH INPUT Due to continuous product improvement, specifications are subject to change
More informationTECHNICAL MANUAL GDS8 & GHS8
TECHNICAL MANUAL AL GDS8 & GHS8 33-3/8" 80% Gas Furnace Units Refer to Service Manual RS6610004 for installation, operation, and troubleshooting information. All safety information must be followed as
More informationOIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.
FORM NO. O11-608 REV. 2 Supersedes Form No. O11-608 Rev. 1 OIL FURNACES CLASSIC PREMIUM CLASS UPF OIL FURNACES ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.30 kw] The Rheem Classic
More informationG26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS
Service Literature G26 SERIES UNITS G26 series units are high-efficiency upflow gas furnaces manufactured with DuralokPlust aluminized steel clamshell-type heat exchangers. G26 units are available in heating
More informationCooling/Heat Pump Convertible Air Handlers
Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way
More informationResidential/Commercial Gas Condensing High Efficiency Tankless Water Heaters
Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger
More informationARMSTRONG AIR HEAT PUMPS www.armstrongair.com
INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM EFC/EFV... 5-10 electric Heat Kits... 5-11 evaporator coils EC1P / EM1P UPFLOW / COUNTERFLOW APPLICATIONS and upflow / horizontal applications (CASED)... 5-6 5-7
More informationThe formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08
Air Volume Requirement Air conditioning systems are engineered with a specific amount of indoor air passing across the surface of the evaporator coil. The amount of air is measured in cubic feet per minute.
More informationCommercial Gas Water Heaters
POWERED BURNER MODELS LARGE-VOLUME POWERED BURNER FEATURES The large-volume powered burner line includes the largest, most powerful A. O. Smith tanktype gas water heaters. With tank capacities up to 600
More informationOIL FURNACES. Clean, Comfortable Oil Heat From
OIL FURNACES Clean, Comfortable Oil Heat From Features 3 1 2 5 10 9 7 6 8 4 1 Foil-faced high density fi berglass insulation gives durable, insulating heat and sound protection. 2 Heavy-duty 14 gauge steel
More informationAIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency
FORM NO. H11-52 REV. 3 Supersedes Form H11-52 Rev. 2 AIR HANDLERS AIR HANDLERS RHLA- Efficiency featuring R-22 Refrigerant RHLL- Efficiency featuring Earth-Friendly R-10A Refrigerant earth friendly refrigerant
More informationSplit System Cooling Product Data
Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-01 Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess
More informationAluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03
Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03 Aluminum Cooling Coil Nomenclature 4 C X C B 0 3 6 C C 3 C U A A Refrigerant Type 4 - R410A Product Family T-Premium (Heat Pump or Convertible
More informationSECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
More informationHigh efficiency, cast-iron gas boiler
SENTRY High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY SENTRY High efficiency, cast-iron gas boiler A smarter choice for informed The boiler you choose for your home
More informationGCS16-024-030-036-048-060
Packaged Unit & Gas Heat 2-5 Ton Capacity 50,000-120,000 Btuh Input Heating Capacity GCS16-024-030-036-048-060 FEATURES Designed for outdoor rooftop or ground level installations Down-flow or horizontal
More information48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT
48/50E-4SB 48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT GAS HEAT ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED
More informationInstallation Manual CLIFC Fan & Coil Variable Speed
Installation Manual CLIFC Fan & Coil Variable Speed General Description GENERAL DESCRIPTION FANS EQUIPMENT Totally Factory assembled within the unit all piping, wiring, and required controls for operation
More informationSplit System Heat Pump Product Data
Split System Heat Pump Product Silver 14 4A6H4 1 1 /2-5 Tons PUB. NO. 12-1175-07 Contents Features and Benefits 2 Model Nomenclature 3 General 4 Product Specifications 4 A-weighted Sound Power Level [db(a)]
More informationGCS16 GCS20 WARNING CAUTION
Service Literature Corp. 0110 L6 Revised 12 2004 GCS16/GCS20 SERIES UNITS GCS16 GCS20 2 to 5 Ton GCS16/20 series units in the 2 to 5 ton (7.0 to 17.0 kw) cooling size are packaged combination gas heat
More informationhttp://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html APPLY POWER TO APPLIANCE FIELD WIRING CORRECT? DPLAY ERROR CODE 1 OR 2 Intelli-Vent TM Sequence of Operation REQUEST FOR HEAT PRESENT?
More informationSplit System Cooling Product Data
Split System Cooling Product Data XR17 4TTR7 2, 3, 4 & 5 Tons PUB. NO. 22-1884-01 Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER All Aluminum SPINE FIN coil DURATUFF
More informationSeries GM. Peerless Boilers. Residential/Commercial Gas Boilers
Peerless Boilers Series GM Residential/Commercial Gas Boilers The Series GM cast iron, hot water boiler is ideal for use in large residences or commercial applications. This gas-fired, atmospheric boiler
More information80UHG. Service Literature
Service Literature Corp. 9728 L12 Revised 01 2002 80UHG 80UHG series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with tubular heat exchangers formed
More informationWON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin 30-34 / March 2013
Bulletin 30-34 / March 2013 INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES General The information on the following pages is to provide the installer the necessary information to properly install the
More informationHEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
More informationYour safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
More informationSplit System Cooling Product Data
Split System Cooling Product Data 4TTB3018-060 1½ 5 Tons PUB. NO. 22-1843-14 Features and Benefits Efficiency up to 13.25 SEER All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, easy
More informationTHC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER
THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented / Unattended Type
More informationIMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.
QUIET-ONE Environmental Products 2000 Kickspace Heater Series Models: KS 2004, KS 2006 KS 2008, KS 2010 INSTALLATION OPERATING MAINTENANCE Please read these instructions thoroughly before beginning your
More informationPropane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL
Propane Conversion Kit Supersedes: 145.25-IOM2 (708) Form 145.25-IOM2 (908) PROPANE CONVERSION KIT INSTALLATION MANUAL "LPKIT " - PROPANE CONVERSION KIT Kits are available for field conversion from natural
More informationGALAXY. High performance gas boilers HOT WATER AND STEAM NATURAL AND L.P. PROPANE GASES
GALAXY High performance gas boilers HOT AND STEAM NATURAL AND L.P. PROPANE GASES GALAXY Cast-iron boilers Slant/Fin s Galaxy is one of America s most trusted gas boilers. Installed in tens of thousands
More informationReplacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
More informationZEPHAIRE G, ZEPHAIRE G PLUS & ZEPHAIRE-200-G GAS CONVECTION OVENS REPLACEMENT PARTS LIST
ZEPHAIRE G, ZEPHAIRE G PLUS & ZEPHAIRE-200-G GAS CONVECTION OVENS REPLACEMENT PARTS LIST EFFECTIVE JULY 29, 2016 Superseding All Previous s Lists. The Company reserves the right to make substitution in
More informationService Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060
4TTM3-SF-1 Service Facts Split System Cooling 4TTM3018-4TTM3060! CAUTION UNIT CONTAINS R-410A REFRIGERANT! R-410A OPERATING PRESSURE EXCEEDS THE LIMIT OF R-22. PROPER SERVICE EQUIPMENT IS REQUIRED. FAILURE
More informationM SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A
Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000
More informationINDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-213 REV. 4 Supersedes Form No. C11-213 Rev. 3 INDOOR COILS RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM
More informationInstallation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008
Installation Manual Rental Services Air Handling Units July 2008 CHS-SVN01A-EN Copyright 2008 Trane All rights reserved This document and the information in it are the property of Trane and may not be
More informationG234X-55 Conventional Gas Boiler
Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus G234X-55 fl oor standing hot water boiler(s), suitable with natural
More informationEFFECTIVE OCTOBER 2005. Atwood Furnaces. and Digital Thermostats
EFFECTIVE OCTOBER 2005 Atwood Furnaces and Digital Thermostats Unique 2-Stage System Set the temperature, turn the thermostat on automatic and let the furnace take over! During cold start-ups, the furnace
More informationExplosion-Proof Electric Unit Heaters
Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,
More informationVertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water
2 to 15 tons Water-Cooled and Chilled Water Unique Solutions for Challenging HVAC Projects Your Choice for Limited Space Applications Water-Cooled Chilled Water The VertiCool Space Saver allows installation
More informationSplit System Heat Pump Product Data
Split System Heat Pump Product Data XL20i 4TWZ0024, 036, 048 & 060 with ComfortLink II and Charge Assist 2, 3, 4 & 5 Tons PUB. NO. 22-1826-01 Features and Benefits Two Climatuff compressors Efficiency
More informationINDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-211 REV. 7 Supersedes Form No. C11-211 Rev. 6 INDOOR COILS RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM
More informationBoiler Plan II Table of Contents
Cover Page Table Of Contents Introduction Parts List Additional Materials Assembly instructions Drawings 1-15 Boiler Plan II Table of Contents Introduction This will be a very rewarding project, if you
More informationGreensource iseries HY Model Unitary Air Handler/Fan Coil
Engineering Submittal Sheet Overview Model Nomenclature HY 035 00-1 HY - HYDRONIC AIR HANDLER NOMINAL CAPACITY IN THOUSANDS OF BTUH VOLTAGE DESIGNATION 1 = 208-230/1/60 ELECTRIC HEAT KW 00 - NO ELECTRIC
More informationCommercial Gas Water Heater
Commercial Gas Water Heater 3-Year Limited Tank/1-Year Limited Parts Warranty* The Polaris has a high grade 444 stainless steel tank with brass connections for years of dependable, trouble-free service
More informationINDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-212 REV. 1 Supersedes Form No. C11-212 INDOOR COILS RCFM- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES
More informationInstallation Instructions
H5HK Series Installation Instructions 3 Phase Electric Heater Kits 7.5 and 0 TON Package A/C Systems Description Installation of 08/40V and 480V H5HK 3 Phase Heater Kits in 7.5 and 0 TON Packaged Air Conditioners.
More information2/4CXC, 2/4CXA, 2/4TXC 2/4TXFH
Cased and Uncased Heat Pump / Cooling Coils 1 1/2-5 Ton 2/4CXC, 2/4CXA, 2/4TXC 2/4TXFH 13 SEER Heat Pump /Cooling Coils for R-22 and R-410A PUB. NO. 22-1773-01 Heat Pump/ Cooling Coil Nomenclature 2 T
More informationTankless water heaters
imagine RHEEM TANKLESS WATER HEATERS never running out of hot water again Tankless water heaters Continuous hot water continuoushot water from Rheem 1-2 RTG-64 Series RTG-64DV, RTG-64X Natural or LP Gas.
More informationUSER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........
More informationHVAC INDOOR MAKE-UP AIR HANDLERS
GIAC-7 HVAC INDOOR MAKE-UP AIR HANDLERS Application Manual PACKAGED INDOOR ARRANGEMENTS FOR MAKE-UP AIR, HEATING AND COOLING Contents 2 PAGE GENERAL INFORMATION 2, 3 MODEL NUMBER DESCRIPTION 4 INDOOR DUCT
More informationSECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
More informationELITE SERIES Up Flow / Horizontal Precision Speed Blower
G S F U R N C E S G50UHi ELITE SERIES Up Flow / Horizontal Precision Speed Blower E N G I N E E R I N G D T Bulletin No. 210380 ugust 2005 Supersedes May 2004 FUE 80% Input 66,000 to 132,000 Btuh Nominal
More informationE2 Series Electric Furnaces
E2 Series Electric Furnaces Service Manual Table of Contents Electrical Requirements... 10 Codes, Specifications Requirements... 10 Connection Supply Service Wires... 10 Furnace Sequence of Operation...
More informationModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60
ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac II air conditioner is a vertical, wall mounted, cost effective air conditioner
More informationOperation and Installation Manual. Max Series
Operation and Installation Manual Max Series Models 95MAX 155MAX 155ECM 155MAXRX 200MAX 200MAXRX MAXTOP 195DCS 300DCS 200ERV 200ERVD New Auto Dehumidistat Function prevents unwanted use of the dehumidistat
More informationSINGLE PACKAGE VERTICAL AIR CONDITIONERS
SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,
More informationCondensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED
High Efficiency Condensing Boilers Proven Reliability, American-Made Home Heating Comfort. Look for this logo throughout this literature to see the unique features that set U.S. Boiler Company apart from
More informationBoston, Venice, Kodiak. Enviro Wood Fireplace Inserts
Boston, Venice, Kodiak Enviro Wood Fireplace Inserts Why buy an Enviro Wood Insert? Up to 84.7% Efficiency - EPA approved and up to 84.7% efficiency - Enviro makes highly efficient wood inserts to help
More informationCABINET. A Clean Burn Heat Exchanger provides approximately 200% more surface area for capturing combustion heat. You get more heat from less oil.
Lanair Clean Burn CABINET Lanair's lightweight heat exchanger provides very little travel for the heat to be picked-up and ultimately be transferred to your shop. It uses a 2-pass design made up of 12
More informationBuck - Boost Transformers
Buck - Boost Transformers Contents Buck - Boost Transformers - Terms & Definitions... 48 Buck - Boost Transformers - Sizing... 50 Quick Reference Chart - 08, 0, 40 Volts Single & Three Phase... 5 Single
More informationCommunicating Controls Service Manual
Communicating Controls Service Manual History 1977 1991 Theory of Operation Common Components Telephone Access Module Service/Troubleshooting Table of Contents Warnings and Cautions... 2 Theory of Operation
More informationGas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems
H15-10 Direct Vent Gas Stove Model H15-NG10 H15-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa) 11 W.C.
More informationINDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-211 REV. 3 Supersedes Form No. C11-211 Rev. 2 INDOOR COILS RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS
More informationSplit System Cooling Product & Performance Data
Split System Cooling Product & Performance Data XR 13 4TTR3018-060 1½ 5 Tons PUB. NO. 22-1790-02-2607 (EN) Features and Benefits Climatuff compressor Efficiency up to 14.00 SEER All aluminum Spine Fin
More informationMODEL TF, RF & SF GAS-FIRED TUBULAR UNIT HEATERS
CATALOG NO.: TFPC-8 SUPERCEDES: TFPC-4 MODEL TF, RF & SF GAS-FIRED TUBULAR UNIT HEATERS REPLACEMENT PARTS CATALOG INDEX WARRANTY INFORMATION RETURN GOODS...2 CONVERSION KITS...3 SF-30/75 SEPARATED COMBUSTION
More informationHEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.
HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET. AFFORDABLE SOLUTIONS FROM AMERISTAR. We know that heating and cooling systems can be a major investment for homeowners. Our goal is
More informationProduct Data. Split System Cooling 22-1904-1F-EN. March 2015
Product Data Split System Cooling 4TTR4018L1000A 4TTR4024L1000A 4TTR4025L1000A 4TTR4030L1000A 4TTR4031L1000A 4TTR4036L1000A 4TTR4037L1000A 4TTR4042L1000A 4TTR4043L1000A 4TTR4048L1000A 4TTR4060L1000A Note:
More informationAir Conditioning Sign-Off Sheet
Air Conditioning Sign-Off Sheet Printed Technician Name Address Social Security Number Telephone Number City State Zip Code Install Or Verify The Accuracy Of An Air Conditioner s Installation The candidate
More informationTWE+TTA TWE+TWA 6.25-20 T.R.
TWE+TTA TWE+TWA 6.25-20 T.R. Main features : TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drive centrifugal fan motor. Aluminium fin coil with copper-tubes.
More informationSplit System Heat Pump Product Data
Split System Heat Pump Product Three Phase 4TWA3030A3000C 4TWA3030A4000C 4TWA3036A3000C 4TWA3036A4000C 4TWA3042B3000A 2½ 5 Tons 4TWA3042B4000A 4TWA3048A3000C 4TWA3048A4000C 4TWA3060B3000A 4TWA3060B4000A
More informationUSER S INFORMATION MANUAL
USER S INFORMATION MANUAL UPFLOW, DOWNFLOW, UPFLOW/HORIZONTAL & HORIZONTAL ONLY INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this
More informationCB29M Bulletin #490071 February 1996
ENGINEERING DT MTCHED REMOTE SYSTEMS 50hz S LOWER UNITS 50hz ELITE 10 MULTI POSITION LOWER UNITS 20 100 to 49 00 tuh (5.9 to 14.4 kw) Cooling Capacity 19 700 to 49 100 tuh (5.8 to 14.4 kw) Heat Pump Heating
More informationInstaller s Guide 18-AH39D1-13
18-AH39D1-13 Cased Aluminum "Convertible" Coils 4TXCA018BC3HC** 4TXCA024BC3HC** 4TXCB025BC3HC** 4TXCB026BC3HC** 4TXCB031BC3HC** 4TXCB032BC3HC** ALL phases of this installation must comply with NATIONAL,
More informationNew Deluxe Wall Mounted Heat Pump Series EXTERIOS
New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History
More informationwww.regency-fire.com GAS STOVES woo GAS STOVES
www.regency-fire.com GAS STOVES woo GAS STOVES Why choose Regency? Beautiful Home Heating Solutions Regency Fireplace Products was founded over 35 years ago with a mission to produce the finest fireplace
More informationFTQ. Daikin Inverter Ducted Heat Pump
FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative
More informationSplit System Heat Pump Product Data
Split System Heat Pump Product Data XR 13 4TWR3018-060 1½ 5 Tons PUB. NO. 22-1795-12 Features and Benefits Climatuff compressor All aluminum Spine Fin coil Quick-Sess cabinet, service access and refrigerant
More informationSL280UHV SERIES GAS FURNACE WARNING
2010 Lennox Industries Inc. Dallas, Texas, USA 506677 01 11/2010 Supersedes 506409 01 SL280UHV SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could
More informationInnovent LASER Packaged Fresh Air Conditioning Units
LASER Latent And Sensible Energy Reduction Latent And Sensible Energy Reduction For Outside Air Innovent LASER Packaged Fresh Air Conditioning Units Innovent LASER units provide both sensible and latent
More informationRESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00
RESIDENTIAL HEATING OIL SERVICE CONTRACT This service contract covers all routine service and maintenance of your residential oil fired furnace or boiler. In addition this contract covers all service calls
More informationSplit System Cooling Product Data
Split System Cooling Product Data Three Phase 4TTA3 2½ 5 Tons PUB. NO. 22-1791-12 Features and Benefits All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, service access and refrigerant
More informationPRODUCT DESIGN. 5. Furnace awaits call from thermostat.
Goodman / Amana Distinctions Brand Single-Stage 80% or 90% Furnaces White-Rodgers 50A55 Integrated Ignition Control 1. 115 VAC power applied to furnace. 2. Integrated ignition control module performs internal
More informationCustomized Server Cabinets
GOING GREEN WITH CUSTOMIZABLE CABINETS AND RACKS Designed to provide industry leading airflow, CyrusOne s cabinets and rack solutions promote optimal cooling and contribute to reduced power consumption.
More informationHeating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
More informationUSER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat
Builder MODEL 1010 Series Non-Programmable Single Stage Heat/Cool Thermostat USER MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage
More informationLH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_071015. Products that provide lasting solutions.
LH and GH/GL Series UNIT COOLERS Technical Bulletin: LHGH_001_07101 Products that provide lasting solutions. LH Series Unit Coolers Dual Discharge Low Hite Series At 9 1/ maximum height, the LH Series
More informationBUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
More information