NEMA 1 ( IP23 ) NEMA 12 ( IP54 )
|
|
- Edwin Hopkins
- 7 years ago
- Views:
Transcription
1 NEMA 1 ( IP23 ) NEMA 12 ( IP54 )
2 Celebrate Our 100th Anniversary With Us
3 Table of Contents TDL Series NEMA TDE Series NEMA TDA Series NEMA Auxiliary Power TLA Series NEMA Dual Secondary ADL Series NEMA TDG12 Giant Series NEMA TM Series Compact Style TDFM12 Series Slimline Options Description Red on Pilot Light Green on Pilot Light Duplex Receptacle (NEMA 1) Gasketed Duplex Receptacle GFI Receptacle Ground Fault Lights 100K AIC Rating Delete Feature Provides 200K AIC Constant Voltage Lighting Disconnects Suffix R G D C F Z Y X Contact Factory Consult Factory
4 Disconnect Electric Manufacturing Company is pleased to display its new line of Lighting Disconnects. The products in this catalog represent the most advanced series of disconnects available in the market today. Most important, these products have the approvals and certifications needed to compete and ship virtually worldwide. All Disconnects are UL Listed and Canadian UL Listed. UL File E In addition, all series, except Series TDG12, ADL, and ADL12, are CE Marked and Licensed for the European Union T Mark under the EN /30-06 Safety of Machinery Standard. These Disconnects have undergone extensive testing and certification by TÜV Rheinland and Underwriters Labs. With Disconnects, approvals are built in - not a high cost option. Disconnects are manufactured in 11 distinct series with features to meet all your transformer lighting disconnect needs: NEMA 1/IP23 and NEMA 12/IP54/IP65 enclosure styles. Domestic and multitap European voltage combinations. Finger - Safe fuses and transformer terminals. CE Marked, TÜV Bauart Marked, copper wound transformers. European and domestic color coded labels and switches. Custom designs through 15 k and Remote Mount models available. Disconnects comply with automotive specifications. Extensive third party approvals provide great flexibility in design variation. Contact your distributor, your Representative or the factory if the voltage combination, or configuration needed is not shown in this catalog. We would be glad to share our specialty design programs with you to provide disconnects matching the precise specifications required. Note: and weights may vary. Please consult factory for certified drawings. 2 Electric Manufacturing Corporation
5 Lighting Disconnect Series TDL Fuse F1 & F2 Fuse F3* Lighting Duplex Fuse F4 250 TDL TDL TDL TDL TDL TDL TDL NEMA 1 / IP 23 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 50 / 60 Hz. One side of secondary grounded. is copper wound metal screen). All overcurrent protection provided: Primary - Class CC Secondary - Supplementary fuses (13/32 x 1Z\x ). Complies with automotive industry specifications. Duplex on 1000 through 3000, optional on Options: Green, ON pilot light available as additional cost option. Other voltage Series TDL A B C D E F Series TDL Outline Drawings Receptacle Supplied on 1 k and Larger Side View
6 Lighting Disconnect Series TDL12 Fuse F1 & F2 Fuse F3* Lighting Receptacle Fuse F4 250 TDL TDL TDL TDL TDL TDL TDL NEMA 12 / IP 54 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 50 / 60 Hz. One side of secondary grounded. is copper wound metal screen). All overcurrent protection provided: Primary - Class CC Secondary - Supplementary fuses (13/32 x 1 Z\x ). Complies with automotive industry specifications. Gasketed receptacle available as an added cost option on all sizes. Green ON pilot light provided. Options: Other voltage Series TDL12 A B C D E F G Series TDL12 Outline Drawings Optional Receptacle Available Bottom View 4 Electric Manufacturing Corporation
7 Lighting Disconnect Series TDE 380 V Fuse F3* Lighting Duplex Primary max amps for other voltages may be obtained by dividing capacity by line voltage. Fuse F4 250 TDE TDE TDE TDE TDE TDE TDE NEMA 1 / IP 23 enclosure. Primary Voltage: 380/400/ 416/440/460/480/575 C. Secondary Voltage: 110/115/120 C. 50 / 60 Hz. One side of secondary grounded. is copper wound metal screen). Overcurrent protection provided: Primary - Class CC Fuse holders only. Secondary - Supplementary fuses (13/32 x 1 Z\x ). Duplex receptacle available as an added cost option on all sizes. Green ON pilot light provided. Options: Other voltage Series TDE A B C D E F Optional Receptacle Available Series TDE Outline Drawings Side View
8 Lighting Disconnect Series TDE V Fuse F3* Lighting Receptacle Primary max amps for other voltages may be obtained by dividing capacity by line voltage. Fuse F4 250 TDE TDE TDE TDE TDE TDE TDE NEMA 12 / IP 54 enclosure. Primary Voltage: 380/400/ 416/440/460/480/575 C. Secondary Voltage: 110/115/120 C. 50 / 60 Hz. One side of secondary grounded. is copper wound metal screen). Overcurrent protection provided: Primary - Class CC Fuse holders only. Secondary - Supplementary fuses (13/32 x 1 Z\x ). Gasketed receptacle available as an added cost option on all sizes. Green ìon pilot light provided. Options: Other voltage Series TDE12 A B C D E F G Optional Receptacle Available Series TDE12 Outline Drawings Bottom View 6 Electric Manufacturing Corporation
9 Series TDA Disconnect - Auxiliary Power Fuse F1 & F2 * Lighting Duplex * Lighting amps and. duplex amps must not exceed total secondary max amps when used simultaneously. 500 TDA TDA TDA TDA TDA TDA NEMA 1 / IP 23 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 50 / 60 Hz. Both sides of secondary isolated from ground. is copper wound metal screen). Primary overcurrent protection provided: Primary - Class CC Secondary fuse holders only for 13/32 x 1 Z\x fuses. Complies with automotive industry specifications. Duplex on all sizes. Green ON pilot light provided. Options: Other voltage Series TDA A B C D E F Series TDA Outline Drawings Side View
10 Disconnect - Auxiliary Power Series TDA12 Fuse F1 & F2 Fuse F3* & F4 Lighting Receptacle 500 TDA TDA TDA TDA TDA TDA NEMA 12 / IP 54 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 50 / 60 Hz. Both sides of secondary isolated from ground. is copper wound metal screen). All overcurrent protection provided: Primary - Class CC Secondary - Supplementary fuses (13/32 x 1 Z\x ). Complies with automotive industry specifications. Gasketed receptacle available as an added cost option on all sizes. Green ON pilot light provided. Options: Other voltage Series TDA12 A B C D E F G Series TDA12 Outline Drawings Optional Receptacle Available Bottom View 8 Electric Manufacturing Corporation
11 Dual Secondary Lighting Disconnect Series TLA Fuse F1 & F2 One Secondary 1 Secondary 2 One One Fuse F3* & F4 Two Two Two Fuse F TLA TLA TLA TLA TLA TLA TLA TLA NEMA 1 / IP 23 enclosure. Primary Voltage: 480 C. 50 / 60 Hz. Secondary One: 120 C. Secondary Two: 120 C. Disconnect features dual isolated secondaries for load isolation. Secondary One: Both sides ungrounded. Secondary Two: One side grounded. is copper wound metal screen) between primary and secondary and between secondary one and secondary two. All overcurrent protection provided: Primary - Class CC Secondary - Supplementary fuses (13/32 x 1 Z\x ). Duplex receptacle optional on all sizes. Green ON pilot light optional on all sizes. Other options: Other voltage A B C D E F Series TLA Series TLA Outline Drawings Optional Receptacle Available Side View
12 Dual Secondary Lighting Disconnect Series TLA12 Fuse F1 & F2 One Secondary 1 Secondary 2 One One Fuse F3* & F4 Two Two Two Fuse F TLA TLA TLA TLA TLA TLA TLA TLA NEMA 12 / IP 54 enclosure. Primary Voltage: 480 C. 50 / 60 Hz. Secondary One: 120 C. Secondary Two: 120 C. Disconnect features dual isolated secondaries for load isolation. Secondary One: Both sides ungrounded. Secondary Two: One side grounded. is copper wound metal screen) between primary and secondary and between secondary one and secondary two. All overcurrent protection provided: Primary - Class CC Secondary - Supplementary fuses (13/32 x 1 Z\x ). Green ON pilot light provided. Gasketed receptacle optional on all sizes. Other options: Other voltage A B C D E F G Series TLA12 Series TLA12 Outline Drawings Optional Receptacle Available Bottom View 10 Electric Manufacturing Corporation
13 Lighting Disconnect Series ADL Fuse F1 & F2 Fuse F3* Lighting Duplex Fuse F4 250 ADL ADL ADL ADL ADL ADL ADL NEMA 1 / IP 23 enclosure Primary Voltage: 480 C Secondary Voltage: 120 C. 60 Hz. One side of secondary grounded. is copper wound metal screen). All overcurrent protection provided: Primary - Class CC Secondary - Supplementary fuses (13/32 x 1 Z\x ). Complies with automotive industry specifications. Duplex on 1000 through 3000, optional on Options: Green or red ON pilot light available as additional cost option. Other voltage Series ADL A B C D E F Series ADL Outline Drawings Receptacle Supplied on 1 k and Larger Side View
14 Lighting Disconnect Series ADL12 Fuse F1 & F2 Fuse F3* Lighting Receptacle Fuse F4 250 ADL ADL ADL ADL ADL ADL ADL NEMA 12 / IP 54 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 60 Hz. One side of secondary grounded. is copper wound metal screen). Complies with automotive industry specifications. All overcurrent protection provided: Primary - Class CC Secondary - Supplementary fuses (13/32 x 1 Z\x ). Gasketed receptacle available as additional cost option. Green ìon pilot light provided. Options: Other voltage combinations are available. Red ON pilot light available. Series ADL12 A B C D E F G Series ADL12 Outline Drawings Optional Receptacle Available Bottom View 12 Electric Manufacturing Corporation
15 Large Lighting Disconnect Series TDG12 Fuse F1 & F2 Fuse F3* Fuse with Receptacle F3* Fuse with Receptacle F TDG TDG NEMA 12 / IP 54 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 60 Hz. Large capacity and One side of secondary grounded. is copper wound metal screen). Green ON pilot light provided. All overcurrent protection provided: Primary - Class CC Secondary - Supplementary fuses (1 1/16 x 2 C\, ). Gasketed duplex receptacle available as additional cost option. Options: Other voltage Custom sizes to 15 k available. Series TDG12 A B C D E F G Optional Receptacle Available Series TDG12 Outline Drawings Bottom View
16 Compact Lighting Disconnects Series TMA, TMB and TMC The Compact Series Lighting Disconnects are designed to minimize backplate footprints to save valuable control panel space. The Compact Series are available in three standard circuits with four sizes for each circuit configuration. Epoxy encapsulated, the Compact Series offers cool operating temperatures, a green ON pilot light, and circuit options that include a duplex receptacle as well as grounded and ungrounded secondaries. Circuit Style Fuse F1 & F2 Fuse F3* Lighting Duplex Fuse F4 250 TMA-130 A TMA-170 A TMA-190 A TMA-200 A TMB-130 B TMB-170 B TMB-190 B TMB-200 B TMC-130 C TMC-170 C TMC-190 C TMC-200 C Total of lighting amps and duplex amps must not exceed secondary amp rating. Fuse sizes of F3 and F4 are based on the load and maximum secondary amps. NEMA 1 / IP 23 enclosure. Primary Voltage: 480 C. Secondary Voltage: 120 C. 60 Hz. Compact, panel space-saving design. Choice of three circuit designs. is copper wound with electrostatic shield (earth metal screen). Green ON pilot light provided. Primary overcurrent protection provided: Primary - Class CC Options: Other voltage Complies with automotive industry specifications. Please contact your Representative or our offices for literature on the full line of Disconnects, s and other products. 14 Electric Manufacturing Corporation
17 Circuit Configurations Compact Lighting Disconnects Series TMA Series TMB Series TMC A B C D E F Series TMA Series TMB & TMC
18 OEM Product Groups Series TDFM12 TDFM12 series is a flange mount lighting disconnect in a NEMA 12 enclosure. The enclosure has provisions for side mounting or base mounting. This is used predominantly in automotive plants. Standard voltage is 480 to 120. s from Power-on pilot light All overcurrent protection provided Lockable Allen Bradley 30 amp switch Continuous welded seams Hinged door with gasketing Special voltages available Other options- consult factory RATING CATALOG NUMBER WEIGHT (LBS) 1000 TDFM TDFM TDFM TDFM General Purpose Dry Type Distribution Single Phase, Three Phase, Buck Boost, Motor Drive Isolation, Custom Designs Single Phase, k - Series 35, 80, 85, 61 Three Phase, 3 k k - Series 63, 76 Buck - Boost, 50-5 k - Series 35, 80, 85 Motor Drive Isolation, 3 k k - Series 63 CE Marked Single and Three Phase Units - Series ES-11, Series ES-31 K Factor, 15 k k - Series TK Custom Designs - Core and Coil Designs - Autotransformers - UL and CSA Family Approvals Industrial Control s, Servo Drive Isolation s Century Series , 103, 107, 109 Primary Installed Fuse Available Series 50, Screw Terminals - Domestic Suffix 052, 053, 054, 056, Export Suffix 058, 059 Series HC, Molded Terminals - Suffix -41, -44, -46, -47 Series HC, Molded Terminals w/ Preconnected Fuse Holders - Suffix -4100, CE Marked Units - Series ES-10 - Suffix.326,.366,.376,.386 Servo Drive Isolation Transfomers - Allen Bradley Type Other Manufacturers Available Custom Designs - UL and CSA Family Approvals 16 Electric Manufacturing Corporation
19 Disconnect EU Declaration of Conformity Declaration of Conformity According to EN/IEC Manufacturerís Name: Electric Mfg. Company Manufacturerís Address: 2987 Franklin Street Detroit, Michigan U.S.A. Electric Mfg. Company declares that the product prefixes cited below: Model Numbers: Series TDL Series TDL12 Series TDE Series TDE12 Series TDA Series TDA12 Series TLA Series TLA12 Series DES ( Specialty / Custom Applications ) Conform to the following standards: Supplementary Information: Safety: EN/IEC , JULY, 2006 Safety of Machinery- Electrical Equipment of Machines EN 61558, Isolating s and Safety Isolating Requirements When properly installed and used, the Disconnect Series cited above meet the essential requirements, are in conformity with, and the CE Marking has been applied, according to the relevant EC Directives listed above and appropriate sections of the Low Voltage Directive 73/23/EEC. Licensed by TÜV Rheinland of North America, Inc, license T , dated December 5, Electric Manufacturing Company Dave Shah Chief Engineer Detroit, Michigan USA January, 1998 Approved By: D. Shah Initial Written By: C. Lincoln Initial Revision 1.3 Date 4/1/
20 Electric Manufacturing Company CE Marked Disconnects Disconnects provide off the shelf solutions for lighting and auxilary power to control panels world wide. All disconnects are UL and Canadian UL Listed. In addition, most series have been tested and licensed by TÜV Rheinland as being in compliance with EN and EN These products bear both the CE Mark and the European Union "T Mark under the Safety of Machinery Standard. With Disconnects, approvals are built in - not a high cost option. CE Marked s also supplies single and three phase CE Marked transformers. Series ES s offer a global solution for transformer acceptability and reliability. Series ES are UL and Canadian UL Listed, CE Marked, and have been tested and licensed by TÜV Rheinland as being in compliance with EC Directives and the relevant sections of the Low Voltage Directive. Request Transfax Bulletin 107 for more information.
Buck - Boost Transformers
Buck - Boost Transformers Contents Buck - Boost Transformers - Terms & Definitions... 48 Buck - Boost Transformers - Sizing... 50 Quick Reference Chart - 08, 0, 40 Volts Single & Three Phase... 5 Single
More informationHPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80
Buck-Boost Transformers Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...
More informationBussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1
How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module
More informationIndustrial Control Power Transformers
Class MT Features Epoxy-encapsulated (50 5000); Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments
More informationCompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
More informationThree Phase Transformers
Three Phase Transformers ontents Three Phase - General Purpose... 26 Three Phase - General Purpose Scott ed... 30 Three Phase - dditional ombinations vailable... 31 Three Phase - ion Diagrams... 32 Series
More informationSURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
More informationDistribution Dry Type Transformers
8 TRASFORMERS Distribution Dry Type Transformers Table (Contact Sales office for List Price) (commonly used) 1a. 115 C Rise F 1b. 80 C Rise B 4. Wall Brackets1 W 6. Low noise XdB below std. LX Type bg
More informationPROPER SELECTION OF CONTROL CIRCUIT TRANSFORMERS WHITE PAPER BULLETIN 1497, 1497A, AND 1497B
WHITE PAPER PROPER SELECTION OF CONTROL CIRCUIT TRANSFORMERS BULLETIN 1497, 1497A, AND 1497B CONTROL CIRCUIT TRANSFORMERS The proper selection of the control circuit transformers is important for suitable
More informationCircuit Breakers. Next Generation of Protection Capabilities
Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many
More informationMetallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features
Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case
More informationLow Voltage Transformers Sealed, General Purpose, Dry Type
Low Voltage Transformers Sealed, General Purpose, Dry Type Catalog 7400CT9601R4/08 08 Class 7400 CONTENTS Description..............................................Page Introduction.................................................
More information8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
More informationTerminal Blocks & Power Distribution Terminal Blocks. Make your connection
Terminal Blocks & Power Distribution Terminal Blocks Make your connection IEC TERMINAL BLOCKS PRODUCT SPOTLIGHT Leading the industry in efficiency and productivity, the Bulletin 1492 family of IEC terminal
More informationREB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 Manually Operated Electronic Speed Controller Single Phase For all applications using suitably specified single-phase induction motor fans 1 GENERAL The
More informationPLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
More informationFilterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000
Filterfans Patented Click & Fit design provides a hardware free installation! Poured-in foam gasket allows for quick NEMA 12 sealing against the enclosure (except PF 1000) Plastic made from strong (ABS-FR),
More informationSECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS
SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section
More informationSingle Phase Three Phase Single Phase Export Model Transformers Single Phase Buck and Boost Transformers Stainless Steel Enclosed Transformers
Transformers Selection Guide Description Page Three Phase Single Phase Aluminum, Copper, 150 Degree Rise Aluminum, Copper, 115 Degree Rise Aluminum, Copper, 80 Degree Rise Epoxy Encapsulated Aluminum,
More informationEmirates Aluminium starts up World s first fully integrated power distribution system from ABB
Reprint from Aluminium World 2009, Volume 2 Emirates Aluminium starts up World s first fully integrated power distribution system from ABB Emirates Aluminium (EMAL), a joint venture between Abu Dhabi s
More information12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST
12VDC MAGNETIC ED DIMMABE POER SUPPIES SPEC SEET DIGEST TM-30-DIM TM-50-DIM T-60-DIM TM100-DIM TM200-DIM TM300-DIM iring Diagram for TM-50-DIM and TM-100-DIM ED 12VDC MAGNETIC DIMMABE 30 POER SUPPY Smallest
More informationPower Generation. Power Control PCL System Generator Set Control
Power Generation Power Control PCL System Generator Set Control Solid State Control The Power Control PCL system uses the latest solid state control technology. Designed for the budget-conscious installation
More informationHMI display Installation Guide
HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC
More informationComponent acceptability for CE product Safety
Component acceptability for CE product Safety Technical Note 37 The following component status table applies to the general approval of electrical or electronic safety critical components (e.g. transformers,
More informationSECTION 26 29 23 VARIABLE FREQUENCY DRIVES
SECTION 26 29 23 VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 SCOPE A. Furnish and install individual freestanding variable frequency AC drives (VFD) as shown on the Drawings and specified herein. 1.02
More informationMEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
More informationBulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
More informationELECTRICAL INSPECTION BULLETIN (Effective 2000-03-01)
ELECTRICAL INSPECTION BULLETIN (Effective 2000-03-01) Rule 28-900 Standby Generator Installations Due to the increasing number of standby generator installations being established to maintain continuity
More informationMini Power-Zone Unit Substation
Catalog 7440CT0901 2009 Class 7440 CONTENTS Description............................................. Page Product Description...........................................2 General Information...........................................3
More informationBT300 HVAC Drives Conventional Bypass (C-Bypass) Options
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC
More informationProject Name: Nortrax Section 26 41 00 Project No: 13-013 SURGE PROTECTION DEVICES Page 1
Page 1 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Divisions 1 Specification sections apply to
More information3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?
Tyco Electronics Corporation Crompton Instruments 1610 Cobb International Parkway, Unit #4 Kennesaw, GA 30152 Tel. 770-425-8903 Fax. 770-423-7194 1) What is a transformer and how does it work? A transformer
More informationSUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches
SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches
More informationMagnum Mobile Generator MMG55 Specifications
Empowering Real People Magnum Mobile Generator MMG55 Specifications ENGINE John Deere PE5030TF270 - turbocharged, diesel engine o Prime - 72 hp @ 1800 rpm o Standby - 80 hp @ 1800 rpm o 4 cylinder o 3.0
More informationSpecifications. Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply. SPECIAL TO THIS PRODUCT:
Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply. SPECIAL TO THIS PRODUCT: INCLUSIONS: S&C Switch Operators Type CS-1A are high-speed
More informationSafe Torque Off Option (Series B) for PowerFlex 40P and PowerFlex 70 Enhanced Control AC Drives
User Manual Safe Torque Off Option (Series B) for PowerFlex 40P and PowerFlex 70 Enhanced Control AC Drives Catalog Number 20A-DG01 Topic Page General Description 2 What Is the DriveGuard Safe Torque Off
More information5 Non-Ventilated Automation Transformers
5 Non-Ventilated Automation Transformers Automation Transformers - Non-Ventilated 50 VA to 45 SolaHD encapsulated transformers are rated for Hazardous Locations as well as harsh industrial environments.
More informationCAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a
More informationAMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5
AMFA-27 AMFA-29 Operator s Manual & Installation Instructions Rev. 2.5 Date: 17 July, 2010 Permanently-connected, utility Interactive, single-phase, inverters Model AMFA-27 WIND TURBINE INVERTER (240 VAC
More informationAMPSEAL* Automotive Plug Connector and Header Assembly
AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2
More informationActuator-Sensor-Interface
Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current
More informationPDS-375-TR Touring CB Power/Data Supply Operator s Manual Rev 1.2
PDS-375-TR Touring CB Power/Data Supply Operator s Manual Rev 1.2 2005 City Theatrical, Inc. Patent Pending The PDS-375 TR Power Supply page 2 CONTENTS The City Theatrical PDS-375 TR...3 Cautions...3 Compliance
More informationExplosion-Proof Electric Unit Heaters
Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,
More informationAC SERIES DUAL 1/4 (6.35mm) / XLR
AC SERIES DUAL 1/4 (6.35mm) / XLR The AC Series C type chassis receptacles feature two connectors in the one space saving housing. A combined XLR female receptacle together with a 6.35mm (1/4 ) phone jack
More informationElectrical Grounding. Appendix C
Appendix C Electrical Grounding Low-Voltage Equipment Grounding The most frequently cited Office of Safety and Health Administration (OSHA) electrical violation is improper occupational grounding of equipment
More informationSubmit shop drawings for equipment provided under this section Shop drawings shall indicate:
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,
More informationWhite Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5
White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code June 2015 Revision 1.5 Shalhevet Bar-Asher; SolarEdge Technologies, Inc. Bill Brooks, PE; Brooks Engineering LLC
More informationPump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationGTEC transfer switch open transition
GTEC transfer switch open transition 40-1250 Amp Description The GTEC automatic transfer switch combines reliability and flexibility in a small, economical package for transferring loads between a utility
More informationProduct Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com
Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer
More informationMERSEN. Safety & Reliability for Electrical Power
MERSEN Safety & Reliability for Electrical Power About Mersen Mersen is a global expert in materials and solutions for extreme environments as well as in the safety and reliability of electrical equipment
More informationBuilding an Auto-Start Rotary Three Phase Converter. by: Matt Isserstedt
Building an Auto-Start Rotary Three Phase Converter by: Matt Isserstedt Disclaimer: Electrical wiring is inherently dangerous. No warranties are issued or implied about the safety or success of this system.
More informationCorner-Grounded Delta (Grounded B Phase) Systems
Data Bulletin 2700DB0202R03/12 09/2012 Replaces 2700DB0202R2/09 dated 02/2009 Corner-Grounded Delta (Grounded B Phase) Systems Class 2700 Retain for future use. Introduction Corner-grounded delta systems
More informationDemystifying the European Machinery Directive and SEMI Requirements for the Industrial Automation and Semiconductor Markets
Demystifying the European Machinery Directive and SEMI Requirements for the Industrial Automation and Semiconductor Markets An Overview of Current Changes and Directions By Andras Szende Senior Engineer
More informationRugged & Reliable Power Connections
Rugged & Reliable Power Connections featuring: DECONTACTOR TM Series Switch Rated Plugs & Receptacles High Amperage Plugs & Receptacles Multipin Connectors Benefit from Meltric Plugs, Receptacles, and
More information47000 SERIES - ELECTRONIC TRANSFORMERS
7000 SERIES - ELECTRONIC TRANSFORMERS MYRRA encapsulated electronic transformers are Switched Mode Power Supplies based on Flyback topology. They constitute an interesting alternative to the traditional
More informationProduct Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fire pumps
More informationNRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting
NRG Intelligent Engine Start Battery Charger The Smart Choice for Mission-Critical Engine Starting Fast, accurate, mission-critical charging gives best starting reliability 4-rate, temperature-compensated
More informationMini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications
Product Description Product Description The Mini Power-Zone Unit Substation from Schneider Electric is a miniaturized version of our Power-Zone Unit Substation. Included are: Circuit Breaker Sealed Step-Down
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More informationINSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
More informationSKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function
SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function Document No. 155-751 SKP15U.. Description Only when assembled to Series VGU Gas valves SKP15 electro-hydraulic actuators combine with
More informationPOINT OBSTRUCTION LIGHTS POL EX LED v5 HAZARDOUS LOCATION
Compliances: Class I, Division 2, Groups A B C D, T5 at -40 deg C to +55 deg C* Class I, Zone 2, Groups IIA IIB+H2 IIC, T5 at -40 deg C to +55 deg C* Certified FAA L-810 by Intertek Testing Service (ETL)
More informationNetScanner System. Toronto: 416 754 7008, Montreal: 514 695 5147, Toll Free:1888 754 7008, Email: sales@a-tech.ca; www.a-tech.ca
Networking Solutions NetScanner System 9IFC/90DB/90DC FEATURES Ethernet Interface for NetScanner System Modules Provides Power and Hardware Trigger Interface 10/100 Base-T Auto-Negotiating Universal AC
More informationChrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range
More informationSimplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT
Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT Are You Ready For The New SCCR Marking Requirements? What Is A Short-Circuit Current Rating (SCCR)? SCCRs on components
More informationI nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.
FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More information6 Buck Boost Transformers
6 uck oost Transformers uck-oost transformers are small, single phase, dry type distribution transformers designed and shipped as insulating/isolating transformers. They have a dual voltage primary and
More informationBERTHOLD ELECTRIC GENERATOR CONNECTION CABINET
BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service
More informationAS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves
More informationLTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
More informationD-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns
for harsh & hazardous (classfied) locations Construction Demolition Maintenance Turnarounds Shutdowns D-13 temporary / mobile power Temporary power products are used on industrial and construction sites
More informationR4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
More informationAdvantages of a Company Switch vs. a Safety Switch Receptacle Combination:
Advantages of a Company Switch vs. a Safety Switch Receptacle Combination: Why a Company Switch Delivers Greater Benefits A Lex Products Corporation Whitepaper. Copyright 2012. Overview: Advantages of
More informationIIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel
Explosion protection Description Flameproof enclosures BARTEC B or EJB series are designed to be installed in industrial plants, where potential hazardous atmospheres occur. These areas are either classified
More informationSWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions
SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS POWER DISTRIBUTION RACKS IN A MISSION CRITICAL SYSTEM MODULES IN A MISSION CRITICAL SYSTEM UPS Convertor Main Inverter Load Battery BPC UPS & BATTERY
More informationUniversal MATE-N-LOK Connector System
Universal MATE-N-LOK Connector System 2011 Tyco Electronics Corporation. All Rights Reserved. MATE-N-LOK, TE Connectivity, TE Connectivity (logo) and TE (logo) are trademarks. Other logos, products and/or
More informationShort-circuit current rating (SCCR) of. industrial control panels. NEC Article 409 and UL 508A
Short-circuit current rating (SCCR) of industrial control panels NEC Article 409 and UL 508A Short-circuit current rating (SCCR) of industrial control panels 1 Introduction 2 Overview of NEC Article 409
More informationChrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited
More informationCENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit
Instructions CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit Catalog Number 2100-SD1 Description The Bulletin 2100 smoke detector unit is a 0.5 space factor unit for use in Bulletin
More informationT7079A,B Solid State Remote Temperature Controllers
T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature
More informationMedium Voltage Motor Control Assemblies
Medium Voltage Motor Control Assemblies Arc Resistant AMPGARD.1 Product............................................. 2 Application........................................... 2 Features, Benefits and Functions...................................
More informationProduct Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
More informationInstalling the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Product overview The Tracer ZN517 controller is a field-installed, application-specific controller that provides directdigital
More informationAnalog Servo Drive 25A8
Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit
More informationDimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140)
9-10N Supersedes Selection Data 9-10N, pages, 1-, dated dated March March 1995 1995 Mailed to: E, D, C/9-100A, 31-A, INTERRUPTING CAPACITY RATINGS IEC 947- Interrupting Capacity s➀ Interrupting Capacity
More informationWhale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty.
Whale 3 DC Servo drive User Manual and Installation Guide Contents 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. 2. Electric specifications. 2.1.Operation ranges. 3. Connections
More informationDistribution Dry Type Transformers
Distribution Dry Type s Sentron Power Centers Bolt-in Breaker Option The same economical space saving package, NEMA 3R rated enclosure, and UL listed transformer of the original Sentron Power Center but
More informationElectronic, Digital and Mechanical Vibration Switches
PT500 Electro-Mechanical Vibration Switch Introduction The PT500 is an economical solution that provides basic vibration protection for rotating reciprocating machines. The PT500 uses an inertia sensitive
More informationGeneral Purpose Relays Types K, R, N, and C
General Purpose Relays s K, R, N, and C Catalog 0CT00R/0 00 Class 0 CONTENTS Description............................................. Page R Miniature Plug-in Relays.............................. K Plug-in
More informationVLT Series 3500 Adjustable Frequency Drive Instruction Manual
Adjustable Frequency Drive Instruction Manual VLT Series 3500 Instruction Manual 175R5237 - Document Version 5.00 This manual applies to all VLT Series 3502-3800 Adjustable Frequency Drives with software
More informationAC SERIES-C TYPE DUAL CONNECTORS JACK/XLR
AC SERIES-C TYPE DUAL CONNECTORS JACK/XLR The AC Series C type chassis receptacles feature two connectors in the one space saving housing. A combined XLR female receptacle together with a 6.35mm (1/4 )
More informationDead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms
Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms ABB innovations for changing demands ABB (www.abb.com) is a leader in power and automation technologies that enables utility
More informationis then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
More informationUL 508A Industrial Control Panels Power Distribution and Control. Lunch & Learn Training. 2002 Eaton Corporation. All rights reserved.
UL 508A Industrial Control Panels Power Distribution and Control Lunch & Learn Training 2002 Eaton Corporation. All rights reserved. Agenda Who is UL and what role do they play? What is the UL 508A Standard?
More informationUL TEST REPORT AND PROCEDURE
Issue Date: 2011-12-17 Page 1 of 19 Report Reference # E146893-V1-S24 Revised: 2013-03-21 UL TEST REPORT AND PROCEDURE Standard: ANSI/AAMI ES 60601-1:2005 (Medical electrical equipment Part 1: General
More informationGeneral Purpose, Interposing, Solid-State and Specialty Relays. Bulletin 700
General Purpose, Interposing, Solid-State and Specialty Relays Bulletin 700 Breadth of Product. Ease of Selection. World-class Allen-Bradley relays and timing relays by Rockwell Automation are designed,
More information2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to
More informationCircuit Breakers. NRC Series. NRC Series. 900 www.idec.com
Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,