Wall-Mount Cabinets Product Selection Guide. Rear mounting studs, panel-ready and wall-mounting provisions

Size: px
Start display at page:

Download "Wall-Mount Cabinets Product Selection Guide. Rear mounting studs, panel-ready and wall-mounting provisions"

Transcription

1 Wall-Mount Cabinets Wall-Mount Cabinets Product Selection Guide Wall-Mount Cabinets Product Selection Guide Wall-Mount Wall-Mount Cabinets Cabinets Product Product Selection Selection Guide Guide Wall-Mount FaMily ACCESSPLUS II PROTEK PROTEK DOUBLE-HINGED Description ACCESSPLUS II Double-Hinged Wall- Mount provides both security and accessibility. Designed to hold multiple pieces of voice data equipment. Perfect where space is at a premium. Double hinged wall mount PROTEK Wall-Mount Cabinets are ideal for protecting network equipment beyond typical Type 1 enclosures. Harsh environments Models with A/C units Construction Mild steel Mild steel Mild steel Application Rating Indoors with built-in ventilation areas Indoors and outdoors. Protects from dust, dirt and splashing water. DiMensions Rack Units (RU) Range RUs RUs 7 26 RUs Offers the flexibility and accessibility of a double-hinged wall-mount and the environmental protection of the PROTEK Type 4/12 ratings. Double-hinged wall-mount Harsh environments Models with A/C units Protects from dust, dirt and splashing water. Height in in in. Width in., in in in. Depth in in in. Ratings Loading - Static lbs lbs lbs. Certifications and Listings UL 508A, CSA, NEMA, IEC UL 508A, CSA, NEMA, IEC UL 508A, CSA, NEMA, IEC Type / NEMA / IP Rating Type 1, IP40 Type 1, 4, 12, IP55/IP66 Type 1, 4, 12, IP55/IP66 Plenum Rated Yes Yes Yes structure Front Door Window or solid Window or solid Window or solid Back Keyhole mounting slots, accessory raised pads, cable tie-down points, large cable knock-out Rear mounting studs, panel-ready and wall-mounting provisions Rear mounting studs, panel-ready and wall-mounting provisions Top / Bottom Gland Plate/Cable knock-outs, fan-ready Solid sheet steel construction Solid sheet steel construction Sides Cable knock-outs, fan-ready Solid sheet steel construction Solid sheet steel construction Rack Angles 1 set tapped fully adjustable, plated 1 set tapped fully adjustable, plated 1 set tapped fully adjustable, plated applications Most frequently utilized model for mounting network equipment. Gland-plate offering great for retrofit applications. Ideal for remote areas with harsh environments for network equipment. Extra-deep to accommodate rack equipment. Ideal for remote areas with harsh environments for network equipment. Extra-deep to accommodate rack equipment. Unique Features Single person mounting Latch-free sides permit flush-mounting to adjacent equipment, enclosures and walls Safety glass window units Pole mounting kit available Reversible hinges (left/right) Grounding and bonding provisions Available with T4 A/C units Extra-deep sizes Fully vented with foam-in-place gasket Safety Glass Rack angle standard Grounding and bonding provisions Available with T4 A/C units Extra deep sizes Fully vented with foam-in-place gasket Safety Glass Rack Angle Standard Front and Rear Access Grounding and bonding provisions 894 Subject to Subject change to without change notice without notice PH 763 PH 422 (763) FX FX (763) hoffmanonline.com hoffmanonline.com 2009 Hoffman 2011 Pentair Enclosures Technical Inc. Products Spec C 1

2 Wall-Mount Cabinets Product Selection Guide Wall-Mount Cabinets Product Selection Guide L-BOX D-BOX WIFI ENCLOSURE 2 MODELS COMLINE L-BOX provides convenient mounting and storage for patch panels in a space-saving design. Horizontal cable distribution Copper to fiber Consolidation points Vertical rack angles D-BOX provides convenient mounting and storage for patch panels. Horizontal cable distribution Copper to fiber Consolidation points Fixed and rotating rack angles Provides a secure enclosure for WiFi and other network equipment. Fiberglass does not impede WiFi/WLAN signals. Corrosion resistant Plenum rated Plywood back panel provided Mild steel Mild steel Fiberglass Aluminum Indoors with built-in ventilation areas. Indoors with built-in ventilation areas. Indoors and outdoors plus hazardous areas. Protects from dust, dirt and splashing water. Lightweight, corrosion-resistant aluminum enclosure provides long-lasting protection for electrical and network components for both indoor and outdoor environments. Corrosion-resistant Outdoor applications (OSP) Indoors and outdoors plus hazardous areas. Protects from dust, dirt and splashing water RUs 4 6 RUs Not applicable for smaller model. Optional RU for large model. Not supplied as standard. Optional RUs in in in in in in in in in in in in. 75 lbs. 100 lbs lbs lbs. UL 1863/508A/60905, CSA NEMA, IEC, EIA 310-D UL 1863/508A/60905, CSA, NEMA, IEC, EIA 310-D UL 508A, CSA,NEMA, IEC UL 508A, CSA, NEMA, IEC Type 1, IP40 Type 1, IP40 Type 4, 4X, 12, 13 IP66 Type 3, 3R, 4, 4X, 12, IP66 Yes Yes Yes Solid door only Not applicable Vented wrap-around door Solid with vents Solid or window Solid Keyhole mounting slots, accessory raised pads, cable tie-down points, large cable knock-out Keyhole mounting slots, accessory raised pads, cable tie-down points, large cable knock-out Wood panel standard Rear mounting studs, panel-ready and wall-mounting provisions Cable knock-outs, fan-ready Cable knock-outs, fan-ready Solid fiberglass construction Solid aluminum construction Cable knock-outs, fan-ready Cable knock-outs, fan-ready Solid fiberglass construction Solid aluminum construction 1 set tapped 10-32, plated 1 set fixed tapped 10-32, plated 1 set tapped 10-32, fully adjustable Optional on largest size Optional based on size 1 set tapped 10-32, fully adjustable Vertical equipment mounting provides horizontal cable distribution. Offers a lower-profile installation. Fixed and rotating rack angles for easy equipment mounting. Offers a lowerprofile installation. Indoors and outdoors: Great for tunnels, marinas, outside walls and rooftops. Ideal for wireless applications; signals pass unimpeded through fiberglass. Indoors and outdoors: Great for rooftop, pole mount and tower mounting. Lightweight with corrosion resistance. Removable door Quarter-turn latches with keyed lock Cable tie-down points Mounting screws provided Top and bottom knockouts Cable spool mounting Complete accessories fans, shelves and others Grounding and bonding provisions Removable and reversible door Quarter-turn latches with keyed lock Cable tie-down points Mounting screws provided Grounding and bonding provisions Top and bottom knockouts Cable spool mounting Complete accessories fans, shelves and others Fiberglass is easily punched or drilled Foam-in-place gasketing Removable door with stainless steel hinge pins Window models are scratch-resistant GE Lexan Margard Small model screw cover Large model key lock knob Solar shield provides cooler interior for outdoor applications Foam-in-place gasketing Latching one- and three-point options Door stop Door options removable and heavyduty continuous Grounding and bonding provisions 2 PH (763) PH FX 2211 (763) FX hoffmanonline.com 2600 hoffmanonline.com 2011 Pentair 2009 Technical Hoffman Products Enclosures Inc. Spec C 895

3 II Double-Hinge ACCESSPLUS II Double-Hinge, Type 1 ACCESSPLUS II Double-Hinge Industry Standards UL 508A; Type 1; File No. E61997 cul Listed per CSA C22.2 No ; File No. E EIA 310-D NEMA/EEMAC Type 1 EIC IP20 Per BICSI TDMM Tenth edition, Chapter 7, Telecommunication Enclosures (TE) Application ACCESSPLUS II Cabinets provide security, equipment access, cooling and support for network and other 19-in. rack-mount equipment. The cabinet has three components: front door, center section and wall section. Features Double-hinged for easy equipment access; center section provides 19-in. rack mounting per EIA universal spacing and is accessed through the front door or swing the center section away from the wall section for rear access Round corners; no sharp edges Front door has either a solid steel or hardened, tinted safety-glass window door for superior scratch resistance Center section easily removed from rear section; tool-less oneperson installation possible Self-grounding, plated steel rack angles fully adjustable within center section Wall section provides cable entry and cable management with knockouts or gland plates Gland plate model provides easy retrofit and fast installation and allows for pre-terminated cables or pre-wired patch panels; no need to re-terminate and test Self-locking center-to-wall section latches in two locations Front access to all latches (no exposed side latches); cabinet can be installed tightly in corners Vented sides provide cross flow ventilation to improve heat dissipation Vertical cable manager included in 28-in.-wide models A full line of accessories is available Specifications Front Door (window or solid steel) Composite frame (injection molded top and bottom with extruded composite sides) 140-degree opening door Field-reversible (left or right) hinge Quarter-turn key lock, two keys included Window door is scratch-resistant 1/4-in. tinted safety glass Solid door has 16 gauge steel insert with matching black finish Center Section Welded 14 gauge steel Solid top of center sections provides protection against falling debris Ventilated sides (to which fans can be added) Self-latching closure connects center section to wall section Self-alignment ramp supports center section to wall section Heavy duty center-to-rear section hinge with quick-release selfretained hinge pin eases wall installation Rack-Mounting Angles 12 gauge, plated steel EIA universal spaced 19-in. rack-mounting holes RU marked from bottom to top Tapped holes, 20 mounting screws included Rear Wall Section Welded 14 gauge steel Radius corners; no sharp edges Available with knockouts or gland plates Raised pads for accessory mounting Cable tie-down points for cable management Keyhole mounting holes allow wall section to be mounted over fasteners and eases installation Three cable-entry grommets Finish Pretreated steel coated with RAL 9005 black light-textured, low-gloss polyester powder paint. Other finishes available contact Hoffman Customer Service. Bulletin: DWDH1 896

4 Standard Product Window Door ACCESSPLUS II Double-Hinge Catalog Number AxBxC in. AxBxC mm Rack Units Additional Rack Angles (S=Square Hole) (T=Tapped Hole) EWMW x x x 600 x EWMR24T or EWMR24S EWMW x x x 600 x EWMR36T or EWMR36S EWMW x x x 600 x EWMR48T or EWMR48S EWMW x x x 600 x EWMR60T or EWMR60S EWMW x x x 600 x EWMR72T or EWMR72S EWMW x x x 600 x EWMR24T or EWMR24S EWMW x x x 600 x EWMR36T or EWMR36S EWMW x x x 600 x EWMR48T or EWMR48S EWMW x x x 600 x EWMR60T or EWMR60S EWMW x x x 600 x EWMR72T or EWMR72S EWMW x x x 600 x EWMR24T or EWMR24S EWMW x x x 600 x EWMR36T or EWMR36S EWMW x x x 600 x EWMR48T or EWMR48S B dimension does not include wall-to-center section hinge. 897

5 Standard Product Solid Door ACCESSPLUS II Double-Hinge Catalog Number AxBxC in. AxBxC mm Rack Units Additional Rack Angles (S=SquareHole) (T=Tapped Hole) EWMS x x x 600 x EWMR24T or EWMR24S EWMS x x x 600 x EWMR36T or EWMR36S EWMS x x x 600 x EWMR48T or EWMR48S EWMS x x x 600 x EWMR24T or EWMR24S EWMS x x x 600 x EWMR36T or EWMR36S EWMS x x x 600 x EWMR48T or EWMR48S B dimension does not include wall-to-center section hinge. Standard Product Window Door with Cable Manager Catalog Number AxBxC in. AxBxC mm Rack Units Additional Rack Angles (S=Square Hole) (T=Tapped Hole) Vertical Cable Mgr. Catalog Number a EWMW x x x 700 x EWMR24T or EWMR24S EWMC24 EWMW x x x 700 x EWMR36T or EWMR36S EWMC36 EWMW x x x 700 x EWMR48T or EWMR48S EWMC48 B dimension does not include wall-to-center section hinge. a For additional rack angles, also order vertical cable manager. 898

6 Standard Product Window Door with Gland Plate ACCESSPLUS II Double-Hinge Catalog Number AxBxC in. AxBxC mm Rack Units Additional Rack Angles (S=Square Hole) (T=Tapped Hole) EWMWG x x x 600 x EWMR24T or EWMR24S EWMWG x x x 600 x EWMR36T or EWMR36S EWMWG x x x 600 x EWMR48T or EWMR48S EWMWG x x x 600 x EWMR24T or EWMR24S EWMWG x x x 600 x EWMR36T or EWMR36S EWMWG x x x 600 x EWMR48T or EWMR48S B dimension does not include wall-to-center section hinge. Load Rating Height Load Capacity 24 in. 250 lb. 36 in. 300 lb. 48 in. 350 lb. 60 in. 400 lb. 72 in. 500 lb. 899

7 Vertical Cable Managers for 28-in.-Wide Cabinet ACCESSPLUS II Double-Hinge Use ACCESSPLUS Cable Managers when ordering additional rack angles for 28-in.-wide cabinet. Bulletin: DWDH1 Catalog Number Description Fits Cabinet EWMC24 ACCESSPLUS Vertical Cable Manager in. A = 24.00; B = EWMC36 ACCESSPLUS Vertical Cable Manager in. A = 36.00; B = EWMC48 ACCESSPLUS Vertical Cable Manager in. A = 48.00; B = Vertical Cable Manager Capacity Number of cables at 60 percent filled Cross Section (Area) 5e (0.22 in. dia.) 6 (0.28 in. dia.) 6A (0.35 in. dia.) 24.5 in Rack Angles Bulletin: DWDH1 Catalog Number Description Rack Units Fits Cabinet EWMR24T Fits 24-in. tapped 12 A = EWMR36T Fits 36-in. tapped 19 A = EWMR48T Fits 48-in. tapped 26 A = EWMR60T Fits 60-in. tapped 32 A = EWMR72T Fits 72-in. tapped 39 A = EWMR24S Fits 24-in. square 12 A = EWMR36S Fits 36-in. square 19 A = EWMR48S Fits 48-in. square 26 A = EWMR60S Fits 60-in. square 32 A = EWMR72S Fits 72-in. square 39 A = Fan Kits Bulletin: DWDH1 Catalog Number Description Fits Cabinet EWMF1 4-in. fan with plug and blocking plates, Fits all C = VAC, 100 CFM small EWMF2 4-in. fan with plug and blocking plates, 115 VAC, 100 CFM, large Fits all C = or

8 ACCESSPLUS II Double-Hinge ACCESSPLUS II Double-Hinged DataCom Wall-Mount Cabinet with Gland Plate Application DataCom Wall-Mount Cabinet with Gland Plate Application This cabinet offers significant advantages in retrofit applications. The gland plate is mounted at the top and the bottom to accommodate cable runs from above, below or both. The gland plate casing can be removed while patch panels and associated wiring are brought to the cabinet. 1. Once the wall section is installed on the wall, lay in the patch panel. 2. Install the cable gland plate onto the wall section. 3. Use wire ties or cable wraps to secure the cable to the cabinet. 4. Install the center section, then mount patch panels on rack angles. 5. Close and lock the door. 1 PH FX hoffmanonline.com 2010 Hoffman Enclosures Inc. Spec D 901

9 PROTEK Wall-Mount and Double-Hinge Cabinets PROTEK, Single-Door UL and NEMA Type 4 or 12 Industry Standards UL 508A Listed; Type 4 or 12; File Number E cul Listed per CSA C22.2 No. 94; Type 4 or 12; File Number E61997 NEMA/EEMAC Type 4 or 12 IEC 60529, IP66 or IP55 Application PROTEK Cabinets are an excellent, off-the-shelf choice for mounting 19-in. rack network equipment in wet or dirty environments where floor space is at a premium. Solid or safety glass window door models provide application flexibility. PROTEK Wall-Mount and Double-Hinge Cabinets Features Solid door provides complete physical and visual protection Window door, made with scratch-resistant safety glass, provides equipment monitoring without opening the door to minimize contamination Fully welded and ground body and door construction for longterm good appearance and durability Foam-in-place seamless gasket around door seals against outdoor air infiltration; is non-absorbing and chemical resistant Type 12 cabinets have solid or window doors and a locking wing knob with two keys. They provide security and convenience in indoor applications. Type 4 cabinets have solid doors and a padlock-capable quarterturn latch. They provide easy operation and locking options in indoor and outdoor applications. One set of adjustable, tapped rack angles included Optional square-hole (.375 in.) rack angles available for equipment mounting flexibility Rack angles are plated and self-grounding for durability and safety Collar studs provided on back of cabinet for mounting accessory panels Accessory panels for mounting additional accessories at the back of the cabinet include tie-down points and pre-drilled holes Plenum rated for use in air exchange areas Specifications Doors and body made of 14 gauge steel Convenient studs provided on both door and body for bonding and grounding Rack angles tapped per EIA standards; made of 12 gauge self-grounding plated steel Window is clear,.25-in. thick, scratch- and impact-resistant safety glass Optional polycarbonate window (not plenum rated) can be fieldor factory-installed. Contact Hoffman Customer Service for factory installation. Twenty screws included Finish Pretreated steel coated with RAL 7035 light-gray or RAL 9005 black textured, low-gloss polyester powder paint. Other finishes available contact Hoffman Customer Service. Bulletin: DWS12 Standard Product Window Door, NEMA 12, IP55 Catalog Number AxBxC Finish Rack Units Standard Panel Accessory Panel Additional Optional Rack Angles (Tapped Holes) Additional Optional Rack Angles (Square Holes) PTDW242412B x x Black 12 CP2424 PTP2424A PTRA1924TPL PTRA1924THL 610 x 610 x 305 PTDW242412G x x Gray 12 CP2424 PTP2424A PTRA1924TPL PTRA1924THL 610 x 610 x 305 PTDW362412B x x Black 19 CP3624 PTP3624A PTRA1936TPL PTRA1936THL 927 x 610 x 305 PTDW362412G x x Gray 19 CP3624 PTP3624A PTRA1936TPL PTRA1936THL 927 x 610 x 305 PTDW482412B x x Black 26 CP4824 PTP4824A PTRA1948TPL PTRA1948THL 1232 x 610 x 305 PTDW482412G x x Gray 26 CP4824 PTP4824A PTRA1948TPL PTRA1948THL 1232 x 610 x 305 PTDW242424B x x Black 12 CP2424 PTP2424A PTRA1924TPL PTRA1924THL 610 x 610 x 610 PTDW242424G x x Gray 12 CP2424 PTP2424A PTRA1924TPL PTRA1924THL 610 x 610 x 610 PTDW362424B x x Black 19 CP3624 PTP3624A PTRA1936TPL PTRA1936THL 927 x 610 x 610 PTDW362424G x x Gray 19 CP3624 PTP3624A PTRA1936TPL PTRA1936THL 927 x 610 x 610 PTDW482424B x x Black 26 CP4824 PTP4824A PTRA1948TPL PTRA1948THL 1232 x 610 x 610 PTDW482424G x x x 610 x 610 Gray 26 CP4824 PTP4824A PTRA1948TPL PTRA1948THL 902

10 PROTEK Wall-Mount and Double-Hinge Cabinets Standard Product Solid Door, NEMA 4, IP66 Catalog Number AxBxC Finish Rack Units Standard Panel Accessory Panel Additional Optional Rack Angles (Tapped Holes) Additional Optional Rack Angles (Square Holes) PTDS242412G x x Gray 12 CP2424 PTP2424A PTRA1924TPL PTRA1924THL 610 x 610 x 305 PTDS362412G x x Gray 19 CP3624 PTP3624A PTRA1936TPL PTRA1936THL 927 x 610 x 305 PTDS482412G x x Gray 26 CP4824 PTP4824A PTRA1948TPL PTRA1948THL 1232 x 610 x 305 PTDS242424G x x Gray 12 CP2424 PTP2424A PTRA1924TPL PTRA1924THL 610 x 610 x 610 PTDS362424G x x Gray 19 CP3624 PTP3624A PTRA1936TPL PTRA1936THL 927 x 610 x 610 PTDS482424G x x x 610 x 610 Gray 26 CP4824 PTP4824A PTRA1948TPL PTRA1948THL Standard Product Solid Door, NEMA 12, IP55 Catalog Number AxBxC PTDS242412B x x x 610 x 305 PTDS242412G x x x 610 x 305 PTDS362412B x x x 610 x 305 PTDS362412G x x x 610 x 305 PTDS482412B x x x 610 x 305 PTDS482412G x x x 610 x 305 PTDS242424B x x x 610 x 610 PTDS242424G x x x 610 x 610 PTDS362424B x x x 610 x 610 PTDS362424G x x x 610 x 610 PTDS482424B x x x 610 x 610 PTDS482424G x x x 610 x 610 Rack Units Standard Panel Accessory Panel Additional Optional Rack Angles (Tapped Holes) Additional Optional Rack Angles (Square Holes) 12 CP2424 PTP2424A PTRA1924TPL PTRA1924THL 12 CP2424 PTP2424A PTRA1924TPL PTRA1924THL 19 CP3624 PTP3624A PTRA1936TPL PTRA1936THL 19 CP3624 PTP3624A PTRA1936TPL PTRA1936THL 26 CP4824 PTP4824A PTRA1948TPL PTRA1948THL 26 CP4824 PTP4824A PTRA1948TPL PTRA1948THL 12 CP2424 PTP2424A PTRA1924TPL PTRA1924THL 12 CP2424 PTP2424A PTRA1924TPL PTRA1924THL 19 CP3624 PTP3624A PTRA1936TPL PTRA1936THL 19 CP3624 PTP3624A PTRA1936TPL PTRA1936THL 26 CP4824 PTP4824A PTRA1948TPL PTRA1948THL 26 CP4824 PTP4824A PTRA1948TPL PTRA1948THL 903

11 Industry Standards UL 508A Listed; Type 1; File Number E cul Listed per CSA C22.2 No. 94; Type 1; File Number E61997 NEMA / EEMAC: Type 1 IEC 60529, IP 30 Application PROTEK Fan and Filter Packages are ideal for protecting sensitive 19- in. rack equipment from harmful environmental contaminants such as falling dirt, dust and dripping water. Use where the ambient air can be used to cool the internal equipment and where protection from falling dirt and dripping water is needed. Filters assist in removing contaminants and are easily removed for periodic cleaning without accessing the cabinet. Top-mounted fans provide increased airflow and maximize heat dissipation of internally mounted equipment. Both top-mounted fans and bottom-mounted intake filters are positioned away from 19-in. rack-mounting areas. Features Solid door provides complete physical and visual protection Window door, made with scratch-resistant safety glass, provides equipment monitoring without opening the door to minimize contamination Fully welded and ground body and door construction for longterm good appearance and durability Foam-in-place seamless gasket around door seals against outdoor air infiltration; is non-absorbing and chemically resistant PROTEK Wall-Mount and Double-Hinge Cabinets PROTEK Single-Door Fan and Filter Thermal Packages, UL and NEMA Type 1 Type 12 cabinets have window doors and a locking wing knob with two keys. They provide security and convenience in indoor applications. Type 4 cabinets have solid doors and a padlock-capable, tamperresistant, quarter-turn latch (tool included). They provide easy operation and locking options in indoor and outdoor applications. One set of adjustable tapped rack angles included Optional square-hole (.375-in.) rack angles available for equipment mounting flexibility Rack angles are plated and self-grounding for durability and safety Collar studs provided on back of cabinet for mounting accessory panels Accessory panels for mounting additional accessories at the back of the cabinet include tie-down points and pre-drilled holes Plenum rated for use in air exchange areas Standard Product PROTEK Single Window Door UL Type 1 Fan and Filter Packages Specifications Doors made of 16 gauge steel; body made of 14 gauge steel Convenient studs provided on both door and body for bonding and grounding Rack angles tapped per EIA standards; made of 12 gauge self-grounding plated steel Window is clear,.25-in. thick, scratch- and impact-resistant safety glass Optional polycarbonate window (not plenum rated) can be fieldor factory-installed. Contact Hoffman Customer Service for factory installation. Twenty screws included Pagoda top-mounted 6-in. fan and bottom-mounted 10-in. filter inlet Top shroud protects cabinet and fan from falling debris and dripping water Bottom-mounted air inlet with outside removable and cleanable filter Regular filter cleaning required for optimum thermal performance Operates on 110/115 VAC 50/60 Hz line voltage Standard NEMA 15 A plug internal to the cabinet (5-15P) Finish Pretreated steel coated with RAL 7035 light gray textured, low-gloss polyester powder paint. Other paint finishes available contact Hoffman Customer Service for details. Load Rating WARNING: The cabinet must be safely and correctly mounted to the wall to support the total weight of the cabinet and its contents. Due to various applications and wall constructions, consultation with a structural engineer and analysis of the mounting wall is advised. Bulletin: DWS12 Additional Optional Rack Angles (Tapped Holes) Additional Optional Rack Angles (Square Holes) Catalog Number AxBxC in. AxBxC mm Rack Units Accessory Panels Standard Panels PTDW242424GF x x x 610 x PTP2424A CP2424 PTRA1924TPL PTRA1924THL PTDW362424GF x x x 610 x PTP3624A CP3624 PTRA1936TPL PTRA1936THL PTDW482424GF x x x 610 x PTP4824A CP4824 PTRA1948TPL PTRA1948THL Technical Operating Information Fan Unit (6-in. Fan with Cord) Replacement Filter No. AFLTR10 Hz Voltage VAC CFM 50/60 Hz Full Load 50/60 Hz Noise SIL (db) 50/ /240 36/32.45/.36 50/56 904

12 PROTEK Wall-Mount and Double-Hinge Cabinets Thermal Performance for Fan and Filter Packages PROTEK Fan and Filter Packages calculated thermal performance Max. Internal Temperature: 100 F Voltage / Hertz: 115 VAC/60 Hz Filters: Clean (Regular cleaning required to maintain airflow) Air Volume: 200 CFM (Exact CFM dependant on Voltage, Frequency, and filter efficiency) Max. Elevation: 6,000 ft. (Contact Hoffman for elevations above 6,000 ft.) Thermal Performance PROTEK Fan and Filter Packages Ambient Temperature ( F) Watts (Heat) Dissipated 100 or above Not recommended Consider PROTEK Air Conditioner Package Watts =.316 x CFM x delta T (degrees F) (at sea level) Delta T = Max internal temperature (degrees F) Ambient external temperature (degrees F) Ambient temperature is the air temperature in and around the intake opening of the cabinet. Fan cooling can never cool the equipment below ambient temperature. 905

13 Industry Standards PROTEK Air Conditioner Packages Indoor (Type 12) UL 508A Listed; Type 12; File Number E cul Listed per CSA C22.2 No. 94; Type 12; File Number E61997 NEMA / EEMAC: Type 12 IEC 60529, IP 55 PROTEK Air Conditioner Packages Outdoor (Type 4) UL 508A Listed; Type 12, 4; File Number E cul Listed per CSA C22.2 No. 94; Type 12, 4; File Number E61997 NEMA / EEMAC: Type 12, 4 IEC 60529, IP 66 Application The PROTEK Thermal Package is an excellent, off-the-shelf choice for mounting 19-in. rack network equipment in wet or dirty environments where filtration or air conditioning is required and floor space is at a premium. Complete Fan and Filter and Air Conditioner Packages are available to match application requirements. Features Solid door provides complete physical and visual protection Window door, made with scratch-resistant safety glass, provides equipment monitoring without opening the door to minimize contamination Fully welded and ground body and door construction for longterm good appearance and durability Foam-in-place seamless gasket around door seals against outdoor air infiltration; is non-absorbing and chemically resistant Type 12 cabinets have window doors and a locking wing knob with two keys. They provide security and convenience in indoor applications. PROTEK Wall-Mount and Double-Hinge Cabinets PROTEK Single-Door Thermal AC Package, UL and NEMA Type 4 or 12 Type 4 cabinets have solid doors and a padlock-capable, tamperresistant, quarter-turn latch (tool included). They provide easy operation and locking options in indoor and outdoor applications. One set of adjustable tapped rack angles included Optional square-hole (.375-in.) rack angles available for equipment mounting flexibility Rack angles are plated and self-grounding for durability and safety Collar studs provided on back of cabinet for mounting accessory panels Accessory panels for mounting additional accessories at the back of the cabinet include tie-down points and pre-drilled holes Plenum rated for use in air exchange areas Cabinet shipped with air conditioner uninstalled Standard Product Single Window-Door UL Type 12 Air Conditioner Packages Specifications Doors made of 16 gauge steel; body made of 14 gauge steel Convenient studs provided on both door and body for bonding and grounding Rack angles tapped per EIA standards; made of 12 gauge self-grounding plated steel Window is clear,.25-in. thick, scratch- and impact-resistant safety glass Optional polycarbonate window (not plenum rated) can be fieldor factory-installed. Contact Hoffman Customer Service for factory installation. Twenty screws included Right-side-mounted T4 Line Indoor/Outdoor Air Conditioner Operates on 110/115 VAC 50/60 Hz line voltage Standard NEMA 15 A plug internal to the cabinet (5-15P) See table for technical operating information Routine maintenance required for optimum performance (see service manual) Finish Pretreated steel coated with RAL 7035 light gray textured, low-gloss polyester powder paint. Other paint finishes available contact Hoffman Customer Service for details. Load Rating WARNING: The cabinet must be safely and correctly mounted to the wall to support the total weight of the cabinet and its contents. Due to various applications and wall constructions, consultation with a structural engineer and analysis of the mounting wall is advised. Bulletin: DWS12 Additional Optional Rack Angles (Tapped Holes) Additional Optional Rack Angles (Square Holes) Catalog Number AxBxC in. AxBxC mm Rack Units Accessory Panels Standard Panel PTDW242424GA x x x 610 x PTP2424A CP2424 PTRA1924TPL PTRA1924THL PTDW362424GA x x x 610 x PTP3624A CP3624 PTRA1936TPL PTRA1936THL PTDW482424GA x x x 610 x PTP4824A CP4824 PTRA1948TPL PTRA1948THL Standard Product Single Solid-Door UL Type 4 Air Conditioner Packages Additional Optional Rack Angles (Tapped Holes) Additional Optional Rack Angles (Square Holes) Catalog Number AxBxC in. AxBxC mm Rack Units Accessory Panels Standard Panel PTDS242424GA x x x 610 x PTP2424A CP2424 PTRA1924TPL PTRA1924THL PTDS362424GA x x x 610 x PTP3624A CP3624 PTRA1936TPL PTRA1936THL PTDS482424GA x x x 610 x PTP4824A CP4824 PTRA1948TPL PTRA1948THL Technical Operating Information AC Unit (T150116G100) Replacement Filter No Hz Voltage VAC Phase Max. Amb. Temp. (E) Full Load Amp Max. Amb. Temp. (ºF) Max. Amb. Temp. (ºC) Cord and Plug 60 (50) (235 watts) 3.6 (3.8) 131 (125) 52 (52) 24-in. cord length 5-15PPlug 906

14 PROTEK Wall-Mount and Double-Hinge Cabinets Thermal Performance for Air Conditioner Packages PROTEK Air Conditioner calculated thermal performance AC Performance: 800 BTU/hour or 235 watts Voltage / Hertz: 115 VAC/60 Hz Max. Ambient Temperature: 131 F Min. Ambient Temperature: -40 F Max. Internal Temperature: 100 F (Allowable) Thermal Performance PROTEK Air Conditioner Packages Ambient Temperature ( F) Watts (Heat) Dissipated Cabinet Height: 24 in. Watts (Heat) Dissipated Cabinet Height: 36 in. Watts (Heat) Dissipated Cabinet Height: 48 in N/A N/A N/A = Not applicable and not recommended in these applications 1 BTU = watts 907

15 PROTEK DH Double-Hinge, UL and NEMA Type 4 or 12 PROTEK Wall-Mount and Double-Hinge Cabinets Self-Closing Latch Type 4 Enclosures Industry Standards UL 508A Listed; Type 4 or 12; File Number E cul Listed per CSA C22.2 No. 94; Type 4 or 12; File Number E61997 NEMA/EEMAC: Type 4 or 12 IEC 60529, IP66 or IP55 Application PROTEK DH Cabinets protect equipment in wet or dirty environments and can be pole- or wall-mounted. Available with reversible left or right hinging, the cabinet swings open to provide easy equipment service and installation access. Features Type 12 cabinets available with solid or window doors and have a locking wing knob with two keys. They provide security and convenience in indoor applications. Type 4 cabinets have solid doors and a padlock-capable quarterturn latch. They provide easy operation and locking options in indoor and outdoor applications. Solid door provides complete physical and visual protection Window door, made with scratch resistant safety glass, allows equipment monitoring without opening the door to minimize contamination Double-hinged for easy equipment access Front access to center body hinging and back section latches Exclusive toolless self-fastening latch is easy to open, yet automatically closes securely Latch on front of door eliminates need to access sides to open door or back section latches Latch-free sides permit side of cabinet to be installed tightly into a corner Fully welded and ground body and door construction for longterm good appearance and durability Foam-in-place seamless gasket around door seals against outdoor air infiltration; is non-absorbing and chemical resistant One set of adjustable tapped rack angles included Optional square hole rack angles available for equipment mounting flexibility Rack angles are plated and self-grounding for durability and safety Collar studs provided on back of cabinet for mounting accessory panels Accessory panels for mounting additional accessories at the back of the cabinet include tie-down points and pre-drilled holes Plenum rated for use in air exchange areas Available modifications include paint colors, holes and cutouts, and custom sizes Specifications Doors and body made of 14 gauge steel Convenient studs provided on center section for bonding and grounding Rack angles tapped per EIA standards; made of 12 gauge self-grounding plated steel Window is clear,.25 in. thick, scratch and impact resistant safety glass Optional polycarbonate window (not plenum rated) can be fieldor factory-installed. Contact Hoffman Customer Service for factory installation. Twenty screws included Finish Pretreated steel coated with RAL 7035 light gray textured, low gloss polyester powder paint. Other finishes available contact Hoffman Customer Service. Load Rating HEIGHT RATING (in.) 100 lb. (45.4 kg) (in.) 100 lb. (45.4 kg) (in.) 100 lb. (45.4 kg) (in.) 125 lb. (56.7 kg) (in.) 175 lb. (79.4 kg) Options See the appropriate option for more information. Options include: PROTEK DH Type 1, 4 or 12 Double-Hinged Wall-Mount Cabinet Accessory Panels PROTEK Polycarbonate Window Inserts PROTEK Rack Angles Bulletin: DWS12 908

16 Standard Product PROTEK Wall-Mount and Double-Hinge Cabinets Additional Optional Rack Angles (Tapped Holes) Additional Optional Rack Angles (Square Holes) Catalog Number AxBxC in. AxBxC mm Rack Units Door Style UL/NEMA Type IP Rating Accessory Panel Standard Panel PTDHS162415G x x x 610 x Solid 4 IP66 PTPDH1624A A24P16 PTRA1916TPL PTRA1916THL PTDHS162415G x x x 610 x Solid 12 IP55 PTPDH1624A A24P16 PTRA1916TPL PTRA1916THL PTDHW162415G x x x 610 x Window 12 IP55 PTPDH1624A A24P16 PTRA1916TPL PTRA1916THL PTDHS202415G x x x 610 x Solid 4 IP66 PTPDH2024A A24P20 PTRA1920TPL PTRA1924THL PTDHS202415G x x x 610 x Solid 12 IP55 PTPDH2024A A24P20 PTRA1920TPL PTRA1924THL PTDHW202415G x x x 610 x Window 12 IP55 PTPDH2024A A24P20 PTRA1920TPL PTRA1924THL PTDHS242415G x x x 610 x Solid 4 IP66 PTPDH2424A A24P24 PTRA1924TPL PTRA1924THL PTDHS242415G x x x 610 x Solid 12 IP55 PTPDH2424A A24P24 PTRA1924TPL PTRA1924THL PTDHW242415G x x x 610 x Window 12 IP55 PTPDH2424A A24P24 PTRA1924TPL PTRA1924THL PTDHS362415G x x x 610 x Solid 4 IP66 PTPDH3624A A36P24 PTRA1936TPL PTRA1936THL PTDHS362415G x x x 610 x Solid 12 IP55 PTPDH3624A A36P24 PTRA1936TPL PTRA1936THL PTDHW362415G x x x 610 x Window 12 IP55 PTPDH3624A A36P24 PTRA1936TPL PTRA1936THL PTDHS482415G x x x 610 x Solid 4 IP66 PTPDH4824A A48P24 PTRA1948TPL PTRA1948THL PTDHS482415G x x x 610 x Solid 12 IP55 PTPDH4824A A48P24 PTRA1948TPL PTRA1948THL PTDHW482415G x x x 610 x Window 12 IP55 PTPDH4824A A48P24 PTRA1948TPL PTRA1948THL PTDHS242424G x x x 610 x Solid 4 IP66 PTPDH2424A A24P24 PTRA1924TPL PTRA1924THL PTDHS242424G x x x 610 x Solid 12 IP55 PTPDH2424A A24P24 PTRA1924TPL PTRA1924THL PTDHW242424G x x x 610 x Window 12 IP55 PTPDH2424A A24P24 PTRA1924TPL PTRA1924THL PTDHS362424G x x x 610 x Solid 4 IP66 PTPDH3624A A36P24 PTRA1936TPL PTRA1936THL PTDHS362424G x x x 610 x Solid 12 IP55 PTPDH3624A A36P24 PTRA1936TPL PTRA1936THL PTDHW362424G x x x 610 x Window 12 IP55 PTPDH3624A A36P24 PTRA1936TPL PTRA1936THL PTDHS482424G x x x 610 x Solid 4 IP66 PTPDH4824A A48P24 PTRA1948TPL PTRA1948THL PTDHS482424G x x x 610 x Solid 12 IP55 PTPDH4824A A48P24 PTRA1948TPL PTRA1948THL PTDHW482424G x x x 610 x Window 12 IP55 PTPDH4824A A48P24 PTRA1948TPL PTRA1948THL 909

17 Industry Standards UL 508A Listed; Type 1; File Number E cul Listed per CSA C22.2 No. 94; Type 1; File Number E61997 NEMA / EEMAC: Type 1 IEC 60529, IP 55 Application PROTEK Fan and Filter Packages are ideal for protecting sensitive 19-in. rack equipment from harmful environmental contaminants such as falling dirt, dust and dripping water. Use for applications where the ambient air can be used to cool the internal equipment and where protection from falling dirt and dripping water is needed. Filters assist in removing contaminants and are easily removed for periodic cleaning without accessing the cabinet. Top-mounted fans provide increased airflow and maximize heat dissipation of internally mounted equipment. Both top-mounted fans and bottom-mounted intake filters are positioned away from 19-inch rack-mounting areas. Features Solid door provides complete physical and visual protection Window door, made with scratch-resistant safety glass, provides equipment monitoring without opening the door to minimize contamination Fully welded and ground body and door construction for longterm good appearance and durability Foam-in-place seamless gasket around door seals against outdoor air infiltration; is non-absorbing and chemically resistant Type 1 cabinets have window doors and a locking wing knob with two keys. They provide security and convenience in indoor applications. One set of adjustable tapped rack angles included PROTEK Wall-Mount and Double-Hinge Cabinets PROTEK DH Double-Hinge Fan and Filter Thermal Packages, UL and NEMA Type 1 Optional square hole (.375 in.) rack angles available for equipment mounting flexibility Rack angles are plated and self-grounding for durability and safety Collar studs provided on back of cabinet for mounting accessory panels Accessory panels for mounting additional accessories at the back of the cabinet include tie-down points and pre-drilled holes Plenum rated for use in air exchange areas Double-hinged for easy equipment access Front access to center body hinging and back section latches Exclusive tool-less self-fastening latch is easy to open, yet automatically closes securely Latch on front of door eliminates need to access sides to open door or back section latches Latch-free sides permit cabinet to be installed tightly into a corner Specifications Doors made of 16 gauge steel and body made of 14 gauge steel Convenient studs provided on both door and body for bonding and grounding Rack angles tapped per EIA standards; made of 12 gauge self-grounding plated steel Window is clear,.25-in. thick, scratch- and impact-resistant safety glass Optional polycarbonate window (not plenum rated) can be fieldor factory-installed. Contact Hoffman Customer Service for factory installation. Twenty screws included Pagoda top-mounted 6-in. fan and bottom-mounted 10-in. filter inlet Top fan shroud protects cabinet and fan from falling debris and dripping water Bottom-mounted air inlet with outside removable and cleanable filter Regular filter cleaning required for optimum thermal performance Operates on 110/115 VAC 50/60 Hz line voltage Standard NEMA 15 A plug internal to the cabinet (5-15P) Finish Pretreated steel coated with RAL 7035 light-gray, textured, low-gloss polyester powder paint. Other paint finishes available contact Hoffman Customer Service for details. Load Rating WARNING: The cabinet must be safely and correctly mounted to the wall to support the total weight of the cabinet and its contents. Due to various applications and wall constructions, consultation with a structural engineer and analysis of the mounting wall is advised. Bulletin: DWDH2 Standard Product Double-Hinged Window-Door Type 1 Fan and Filter Packages Additional Optional Rack Angles (Tapped Holes) Additional Optional Rack Angles (Square Holes) Catalog Number AxBxC in. AxBxC mm Rack Units Accessory Panels Standard Panel PTDHW242424GF x x x 610 x PTPDH2424A A24P24 PTRA1924TPL PTRA1924THL PTDHW362424GF x x x 610 x PTPDH3624A A36P24 PTRA1936TPL PTRA1936THL PTDHW482424GF x x x 610 x PTPDH4824A A48P24 PTRA1948TPL PTRA1948THL Load Ratings Height Max. Load Rack Angles Mounted to Center Section Max. Load Accessory Panel Mounted Rear Section to Collar Studs 16 in. 100 lb. 50 lb. 20 in. 100 lb. 80 lb. 24 in. 100 lb. 100 lb. 36 in. 125 lb. 200 lb. 48 in. 175 lbs. 300 lb. 910

18 PROTEK Wall-Mount and Double-Hinge Cabinets Technical Operating Information Fan Unit (6-in. Fan with Cord) Replacement Filter No. AFLTR10 Hz Voltage VAC CFM 50/60 Hz Full Load 50/60 Hz Noise SIL 50/ /240 36/32.45/.36 50/56 db Thermal Performance for Fan and Filter DH Packages PROTEK Fan and Filter Packages calculated thermal performance Max. Internal Temperature: 100 F Voltage / Hertz: 115 VAC/60 Hz Filters: Clean (Regular cleaning required to maintain airflow) Air Volume: 200 CFM (Exact CFM dependant on Voltage, Frequency, and filter efficiency) Max. Elevation: 6,000 ft. (Contact Hoffman for elevations above 6,000 ft.) Thermal Performance PROTEK Fan and Filter Packages Ambient Temperature ( F) Watts (Heat) Dissipated 100 or above Not recommended Consider PROTEK Air conditioner Package Watts =.316 x CFM x Delta T ( F) (at sea level) Delta T = Max internal Temperature (degrees F) Ambient external Temperature (degrees F) Ambient temperature is the air temperature in and around the intake opening of the cabinet. Fan cooling can never cool the equipment below ambient temperature. 911

19 Application PROTEK DH Thermal Packages are an excellent, off-the-shelf choice for mounting 19-in. rack network equipment in wet or dirty environments where filtration or air conditioning is required and floor space is at a premium. These complete packages can be mounted to a pole or wall and hinged on the left or right. The mounted cabinet swings open to provide easy equipment service and installation access. Complete Fan and Filter and Air Conditioner Packages are available to match application requirements. Features Solid door provides complete physical and visual protection Window door, made with scratch-resistant safety glass, provides equipment monitoring without opening the door to minimize contamination Fully welded and ground body and door construction for longterm good appearance and durability Foam-in-place seamless gasket around door seals against outdoor air infiltration; is non-absorbing and chemically resistant Type 12 cabinets have window doors and a locking wing knob with two keys. They provide security and convenience in indoor applications. Type 4 cabinets have solid doors and a padlock-capable, tamperresistant, quarter-turn latch (tool included). They provide easy operation and locking options in indoor and outdoor applications. PROTEK Wall-Mount and Double-Hinge Cabinets PROTEK DH Double-Hinge Thermal AC Package, UL and NEMA Type 4 or 12 One set of adjustable tapped rack angles included Optional square hole (.375 in.) rack angles available for equipment mounting flexibility Rack angles are plated and are self-grounding for durability and safety Collar studs provided on back of cabinet for mounting accessory panels Accessory panels for mounting additional accessories at the back Self-Closing Latch Type 4 Enclosures of the cabinet include tie-down points and pre-drilled holes Plenum rated for use in air exchange areas Double-hinged for easy equipment access Front access to center body hinging and back section latches Exclusive tool-less self-fastening latch is easy to open, yet automatically closes securely Industry Standards Latch on front of door eliminates need to access sides to open door or back section latches PROTEK Air Conditioner Packages Indoor (Type 12) Cabinet shipped with air conditioner uninstalled UL 508A Listed; Type 12; File Number E Specifications cul Listed per CSA C22.2 No. 94; Type 12; File Number E61997 Doors made of 16 gauge steel and body made of 14 gauge steel NEMA / EEMAC: Type 12 IEC 60529, IP 66 PROTEK Air Conditioner Packages Outdoor (Type 4) Convenient studs provided on both door and body for bonding and grounding Rack angles tapped per EIA standards; made of 12 gauge UL 508A Listed; Type 12, 4; File Number E self-grounding plated steel cul Listed per CSA C22.2 No. 94; Type 12, 4; File Number E61997 Window is clear,.25-in. thick, scratch- and impact-resistant safety glass NEMA / EEMAC: Type 12, 4 IEC 60529, IP 66 Optional polycarbonate window (not plenum rated) can be fieldor factory-installed. Contact Hoffman Customer Service for factory installation. Twenty screws included Right-side-mounted T4 Line Indoor/Outdoor Air Conditioner Operates on 110/115 VAC 50/60 Hz line voltage Standard NEMA 15 A plug internal to the cabinet (5-15P) See table for technical operating information Routine maintenance required for optimum performance (see service manual) Standard Product Double-Hinged Window-Door Type 12 Air Conditioner Packages Finish Pretreated steel coated with RAL 7035 light-gray, textured, low-gloss polyester powder paint. Other paint finishes available contact Hoffman Customer Service for details. Load Rating WARNING: The cabinet must be safely and correctly mounted to the wall to support the total weight of the cabinet and its contents. Due to various applications and wall constructions, consultation with a structural engineer and analysis of the mounting wall is advised. Bulletin: DWDH2 Additional Optional Rack Anglesl (Tapped Holes) Additional Optional Rack Angles (Square Holes) Catalog Number AxBxC in. AxBxC mm Rack Units Accessory Panels Standard Panel PTDHW242429GA x x x 610 x PTPDH2424A A24P24 PTRA1924TPL PTRA1924THL PTDHW362429GA x x x 610 x PTPDH3624A A36P24 PTRA1936TPL PTRA1936THL PTDHW482429GA x x x 610 x PTPDH4824A A48P24 PTRA1948TPL PTRA1948THL Standard Product Double-Hinged Solid-Door Type 4 Air Conditioner Packages Additional Optional Rack Anglesl (Tapped Holes) Additional Optional Rack Angles (Square Holes) Catalog Number AxBxC in. AxBxC mm Rack Units Accessory Panels Standard Panel PTDHS242429GA x x x 610 x PTPDH2424A A24P24 PTRA1924TPL PTRA1924THL PTDHS362429GA x x x 610 x PTPDH3624A A36P24 PTRA1936TPL PTRA1936THL PTDHS482429GA x x x 610 x PTPDH4824A A48P24 PTRA1948TPL PTRA1948THL 912

20 PROTEK Wall-Mount and Double-Hinge Cabinets Load Ratings Height Max. Load Rack Angles Mounted to Center Section Max. Load Accessory Panel Mounted Rear Section to Collar Studs 16 in. 100 lb. 50 lb. 20 in. 100 lb. 80 lb. 24 in. 100 lb. 100 lb. 36 in. 125 lb. 200 lb. 48 in. 175 lb. 300 lb. Thermal Performance for Air Conditioner DH Packages PROTEK Air Conditioner calculated thermal performance AC Performance: 800 BTU/hour or 235 Watts Voltage / Hertz: 115 VAC/60 Hz Max. Ambient Temperature: 131 F Min. Ambient Temperature: -40 F Max. Internal Temperature: 100 F (Allowable) Thermal Performance PROTEK Air Conditioner Ambient Temperature ( F) Watts (Heat) Dissipated Cabinet Height: 24 in. Watts (Heat) Dissipated Cabinet Height: 36 in. Watts (Heat) Dissipated Cabinet Height: 48 in. 130 N/A N/A N/A N/A N/A = Not applicable and not recommended in these applications 1 BTU = watts 913

Free-Stand Cabinets PROLINE Network Switch Cabinets

Free-Stand Cabinets PROLINE Network Switch Cabinets 763.422.2588 Spec-00525 M763.422.2661 Free-Stand Cabinets PROLINE Network s Free-Stand Cabinets PROLINE Network s PROLINE Network INDUSTRY STANDARDS EIA 310-D APPLICATION PROLINE Network Switch cabinet

More information

PROLINE Go l d Se r i e s. Desk Consoles and Accessories

PROLINE Go l d Se r i e s. Desk Consoles and Accessories Modular Enclosure Systems Application PROLINE Gold Series desk consoles are ergonomically designed for use in either a sitting or standing position. Single-access consoles have a front door and solid back.

More information

Cabinets 101: Configuring A Network Or Server Cabinet

Cabinets 101: Configuring A Network Or Server Cabinet Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What

More information

Type 1, 3, & 3R Enclosures

Type 1, 3, & 3R Enclosures Junction oxes Type 1 Screw over....................................................................... 50-53 Junction oxes Type 1 Hinge over........................................................................

More information

DCF Optimized Rack System

DCF Optimized Rack System Integrated Cabinet Solutions For Business-Critical Continuity DCF Optimized Rack System User Manual IMPORTANT SAFETY GUIDELINES SAVE THESE INSTRUCTIONS This manual contains important instructions that

More information

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

19 Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted. 19" Data Racks Attractive design and high quality are characteristic. Basic framework is welded from multiple bent metal plate, which assures great rigidity suitable for heavier equipment. All profile

More information

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels

More information

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Lighting Packages. 230 VAC Fluorescent Enclosure Light: Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for

More information

Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?

Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT? Data Bulletin April 2001 Raleigh, NC, USA Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW Variable frequency drives are available from manufacturers as enclosed engineered

More information

Rack Cabinets. Rack Configuration. 19 inch

Rack Cabinets. Rack Configuration. 19 inch Rack Cabinets Rack Configuration 19 inch 19 RACK COMPONENTS FEATURES Hallam Manufacturing s range of 19 inch racks and cabinets for today s data/communications installations are designed and manufactured

More information

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS STANDARD & ECONOMICAL BasicRack A complete low-cost, high-quality basic equipment management system. Design Six web channel holes per side allow

More information

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures SX 8 The SX range comprises 14 sizes of enclosure manufactured in either stainless steel or mild steel. 11 sizes are available in depths of 140 or 200mm and 8 sizes are available in depths of 140, 200

More information

Series 18 Pass Thru Air Lock Cleanroom Entry System

Series 18 Pass Thru Air Lock Cleanroom Entry System OPERATION & MAINTENANCE INSTRUCTIONS FOR Series 18 Pass Thru Air Lock Cleanroom Entry System SOLUTIONS BUILT TO YOUR SPECIFICATIONS 8605 Wyoming Ave. N. Minneapolis MN 55445 fax: 763.425.2004 e-mail: sales@cleanairproducts.com

More information

Customized Server Cabinets

Customized Server Cabinets GOING GREEN WITH CUSTOMIZABLE CABINETS AND RACKS Designed to provide industry leading airflow, CyrusOne s cabinets and rack solutions promote optimal cooling and contribute to reduced power consumption.

More information

SPECTRACOOL AIR CONDITIONERS PENTAIR EQUIPMENT PROTECTION MCLEAN IS NOW HOFFMAN COOLING

SPECTRACOOL AIR CONDITIONERS PENTAIR EQUIPMENT PROTECTION MCLEAN IS NOW HOFFMAN COOLING SPECTRACOOL AIR CONDITIONERS PENTAIR EQUIPMENT PROTECTION MCLEAN IS NOW HOFFMAN COOLING HOFFMAN SPECTRACOOL INDOOR/OUTDOOR AIR CONDITIONERS ENERGY-EFFICIENT, FILTERLESS AIR CONDITIONERS NOW AVAILABLE WITH

More information

DIGITUS Network & Server Cabinets. UNIQUE Series

DIGITUS Network & Server Cabinets. UNIQUE Series DIGITUS Network & Server Cabinets UNIQUE Series Benefits - Server Rack 4-Point locking system front door 3-point locking system rear door Swing handle lock with profile zylinder in front and rear door

More information

Linkeo 19" freestanding cabinets

Linkeo 19 freestanding cabinets 87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3

More information

Fresh Air Enclosure Cooling Filter Fans

Fresh Air Enclosure Cooling Filter Fans 763.576.3200 SPEC-00306 K763.422.2211 COOLING FRESH AIR ENCLOSURE COOLING FILTER FANS Fresh Air Enclosure Cooling Filter Fans TFP SIDE-MOUNT TFP10 215 CFM (365 m3/hr.) TFP6 140 CFM (238 m3/hr.) TFP4 55

More information

Filterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000

Filterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000 Filterfans Patented Click & Fit design provides a hardware free installation! Poured-in foam gasket allows for quick NEMA 12 sealing against the enclosure (except PF 1000) Plastic made from strong (ABS-FR),

More information

REFRIGERATION. Standard Features & Accessories. Model Options. Built-In 30 W. Full-Height Wine Cellar. All models include. VCWB300 Professional

REFRIGERATION. Standard Features & Accessories. Model Options. Built-In 30 W. Full-Height Wine Cellar. All models include. VCWB300 Professional Standard Features & Accessories All models include Capacity accommodates up to 150 full-size bottles o 84 H./24 D. Exclusive TriTemp storage system o Three independent temperature zones o Settings are

More information

Data Centre Solutions

Data Centre Solutions Issue 6 Data Centre Solutions RACKS POWER COOLING MONITORING SECURITY SERVICE & SUPPORT The simple route to the perfect data centre Data centres are complex systems. Software, hardware and IT infrastructure

More information

Cabinet V800 V800 CABINETS

Cabinet V800 V800 CABINETS V800 Cabinet Siemon s V800 cabinets provide a robust, cost-effective enclosure solution that provides valuable Zero-U space on each side of the equipment rails for cable management, PDU mounting or connectivity

More information

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre IT infrastructure Efficiency-boosting solutions nextlevel for data centre 2 Rittal IT infrastructure The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind,

More information

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case

More information

STB Series Enclosures

STB Series Enclosures STB Series Enclosures Features/Applications: The STB series of sheet steel enclosures are designed to meet the requirement for distribution and lighting junction boxes. Available in 14 sizes with standard

More information

Screen Enclosure Protect your Screen against: rain, temperature, vandalism damage and theft

Screen Enclosure Protect your Screen against: rain, temperature, vandalism damage and theft Screen Enclosure Protect your Screen against: rain, temperature, vandalism damage and theft When should I use a LCD enclosure? Designed to tolerate outdoor wet and wash down environments an LCD enclosure

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

JIC CONTINUOUS HINGE BOXES

JIC CONTINUOUS HINGE BOXES JIC CONTINUOUS HINGE BOXES Austin JIC Continuous Hinge (JH) boxes are Underwriters Laboratories Listed and are designed for use as electrical junction boxes, terminal wiring boxes, and instruments housing.

More information

Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to 1.22 1.11

Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to 1.22 1.11 Knürr Miracel 19 Network and Server Rack Platform 1.12 to 1.22 1.11 19" Server Rack: Knürr Miracel Strong points 1.13 Knürr Miracel ASP ASP/Server Rack 1.16 Knürr Miracel Server Rack 1.18 Knürr Miracel

More information

Cooktop Low-Profile Ventilation Hoods

Cooktop Low-Profile Ventilation Hoods INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............

More information

Knürr Smaract. Knürr Smaract. CompactRack

Knürr Smaract. Knürr Smaract. CompactRack CompactRack Features Ample space for components and cabling provided in an efficient, compact design. The innovative frame concept with triangular extrusions ensures low weight while maintaining high stability.

More information

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

SINGLE PACKAGE VERTICAL AIR CONDITIONERS SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,

More information

19" GERMANY EXPORT RACK QUALITY PRODUCT FOR THE BEST WORK NEW DESIGN CABLE MANAGEMENT PANEL WALL RACK CABINET 15 U VENTILATING FAN

19 GERMANY EXPORT RACK QUALITY PRODUCT FOR THE BEST WORK NEW DESIGN CABLE MANAGEMENT PANEL WALL RACK CABINET 15 U VENTILATING FAN NEW DESIGN CABLE MANAGEMENT PANEL WALL RACK CABINET 15 U VENTILATING FAN AC SOCKET STRIP (AC Power Distribution) BLANK PANELS x U OPEN RACK THERMOSTAD PANEL SET CABLE MANAGEMENT PANEL WITH COVER BAYING

More information

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11 Cluster Box Units (CBU s) continued on pages 7-11 CLUSTER BOX UNITS FRONT LOADING Made of heavy duty aluminum and stainless steel hardware, Salsbury 3300 series U.S.P.S. approved Cluster Box Units (CBU

More information

BLADE S-MAX Cabinet for Blade Server

BLADE S-MAX Cabinet for Blade Server Cabinet for Blade Server 1 2 Overview Material specification Corner verticals: 1.5 mm steel End frames: 1.5 mm steel Panel mounts: 2.0 mm steel Panel mount supports: 1.5 mm steel Side panels, door and

More information

Locks, Latches, Inserts, & Handles Flush Locks Illustration Sheet and Catalog Number. Type 1 Enclosure Flush Lock. New Flush lock

Locks, Latches, Inserts, & Handles Flush Locks Illustration Sheet and Catalog Number. Type 1 Enclosure Flush Lock. New Flush lock Locks, Latches, Inserts, & Handles Flush Locks Illustration Sheet and Type 1 Panel Enclosure Flush Lock Type 1 Enclosure Flush Lock T1EFL New Flush lock.886 dia. (22) Hole Pattern Detail Flush Locks are

More information

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009 Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal

More information

CFM @.0 SP H/M/L AFLR-12 12 3.033 1565/1464/1309 60 1836/1469/1175 24/22/20 115 AFLR-20 20 3 1/8 1468/1209/1063 60 7562/6050/4840 34/31/28 115

CFM @.0 SP H/M/L AFLR-12 12 3.033 1565/1464/1309 60 1836/1469/1175 24/22/20 115 AFLR-20 20 3 1/8 1468/1209/1063 60 7562/6050/4840 34/31/28 115 Air Circulators High Velocity Floor Fans Circulate Large Volumes of Air Product Specifications Size Spd HP HZ CFM/WATT @.0 SP AFLR-12 12 3.033 1565/1464/1309 60 1836/1469/1175 24/22/20 115 AFLR-20 20 3

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in

More information

Knürr DCM. Knürr DCM. 19 Server Rack System 19 Heavy Duty Rack 1.2 to 1.9 1.1

Knürr DCM. Knürr DCM. 19 Server Rack System 19 Heavy Duty Rack 1.2 to 1.9 1.1 Knürr DCM 19 Server Rack System 19 Heavy Duty Rack 1.2 to 1.9 1.1 Knürr DCM conquers the world Standardization in the data center begins with the Knürr DCM! The Knürr DCM is the modular building block

More information

Table of Contents. RimatriX5 IT Solutions from Rittal. Product Overview Section 1... Pages 3-11. Enclosures Section 2...

Table of Contents. RimatriX5 IT Solutions from Rittal. Product Overview Section 1... Pages 3-11. Enclosures Section 2... Rittal IT Solutions Table of Contents RimatriX5 IT Solutions from Rittal Product Overview Section 1... Pages 3-11 Enclosures Section 2... Pages 12-51 Cooling Section 3... Pages 52-73 Monitoring and Security

More information

Packaged Terminal Air Conditioner Wall Sleeve Installation

Packaged Terminal Air Conditioner Wall Sleeve Installation Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation

More information

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

LIEBERT VNSA Installation Sheet

LIEBERT VNSA Installation Sheet LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display

More information

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending Patent Pending DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications DuroSite Series LED High Bay Features & Benefits L70 rated for >100,000 hours @ 25 C ambient 5 year full performance

More information

InstaPATCH ZERO Solution Guide

InstaPATCH ZERO Solution Guide SYSTIMAX Solutions InstaPATCH ZERO Solution Guide Rapid Server Deployment and Change Management North, South and Central Americas 1 As data centers face ever-increasing IT demands, growth demands and evolving

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs

More information

Low Voltage Transformers Sealed, General Purpose, Dry Type

Low Voltage Transformers Sealed, General Purpose, Dry Type Low Voltage Transformers Sealed, General Purpose, Dry Type Catalog 7400CT9601R4/08 08 Class 7400 CONTENTS Description..............................................Page Introduction.................................................

More information

Rack Systems Solutions

Rack Systems Solutions Rack Systems Solutions Designed to simplify cable management and improve power distribution Engineered by APC by Schneider Electric for Dell, NetShelter S is the next-generation rack enclosure solution

More information

Temperature Controlled Enclosures

Temperature Controlled Enclosures 7 Indoors or Outdoors - We ve Got You Covered! Temperature Controlled Enclosures Protect your electronics and control their environment! FC Series - NEMA 3R outdoor enclosures with UL Listed fans, filters,

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in cooling California NOx

More information

Secure your IT equipment with confidence... secure with NetClosure

Secure your IT equipment with confidence... secure with NetClosure Secure your IT equipment with confidence... secure with NetClosure SERVER CABINETS NetClosure s REM Series Server Cabinet is the ultimate solution designed and engineered for demanding data center environments.

More information

Explosion-Proof Electric Unit Heaters

Explosion-Proof Electric Unit Heaters Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,

More information

Mini USB and USB 2.0-IP67 Connector System

Mini USB and USB 2.0-IP67 Connector System Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet

More information

Scraper Passage Indicator. Electrical Indicator. Features

Scraper Passage Indicator. Electrical Indicator. Features IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage

More information

ANI-64S-xRU. Single Section Wall Cabinet INSTRUCTION MANUAL

ANI-64S-xRU. Single Section Wall Cabinet INSTRUCTION MANUAL ANI-64S-xRU Single Section Wall Cabinet INSTRUCTION MANUAL 122 Rose Ln., Suite 303, Frisco, Texas 75034 TOLL FREE: 1-877-ANEUTRON TOLL: (469) 362-9228 Email: sales@a-neutronics.com A-Neutronics.com SAFETY

More information

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers An intelligent physical infrastructure is required

More information

PS6500 Storage Arrays Rack Mount Instructions

PS6500 Storage Arrays Rack Mount Instructions PS6500 Storage Arrays Rack Mount Instructions Part Number: R724M Rev. A01 Copyright 2010 Dell, Inc. All rights reserved. Dell is a trademark of Dell, Inc. EqualLogic is a registered trademark. All trademarks

More information

Networking Cabinets > Part No Capacity Available Colors Height(mm) Width(mm) Depth(mm)

Networking Cabinets > Part No Capacity Available Colors Height(mm) Width(mm) Depth(mm) Wall Mount Cabinets Link IT Single Sided Wall Mount Cabinets Welded frame, reliable structure Standing or wall mounting installation Easy mounting installation 19 standard installation Removable side panels,

More information

ADC Structured Cabling Solutions

ADC Structured Cabling Solutions ADC Structured Cabling Solutions The highest performing cross-connect system in the world HighBand Wall Mount Patching Solution Reliable, secure and cost effective ADC s HighBand cross connect solution

More information

SECTION 25110 TELECOMMUNICATION ROOMS

SECTION 25110 TELECOMMUNICATION ROOMS PART 1 - GENERAL 1.1 SUMMARY A. SCOPE SECTION 25110 TELECOMMUNICATION ROOMS 1. This section includes the minimum installation requirements for equipment and cabling infrastructure in Telecommunication

More information

MODEL HSR-007 Direct Drive Rolling Steel

MODEL HSR-007 Direct Drive Rolling Steel MODEL HSR-007 Direct Drive Rolling Steel 200 Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8 Tel: 866-792-9968 or 705-792-9968 Fax: 705-735-9564 www.tnrdoors.com email: info@tnrdoors.com Model HSR-007

More information

Easy Installation All five standard monitors fit into shallow mounting areas, requiring about 3" of depth. The XT1502, SXT1811, and SXT2011 models hav

Easy Installation All five standard monitors fit into shallow mounting areas, requiring about 3 of depth. The XT1502, SXT1811, and SXT2011 models hav Flat Panel Industrial Monitors FEATURES 10.4 to 20.1 bright, easy-to-read color TFT flat panel display with screen resolution from VGA to SXGA Large viewing area and viewing angles Operator input through

More information

F9MXE. Product Specifications

F9MXE. Product Specifications 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Select models earn the ENERGY STAR (See below, indicated with check mark.) Xtra SEER ECM blower motor Supports

More information

Installation Manual CLIFC Fan & Coil Variable Speed

Installation Manual CLIFC Fan & Coil Variable Speed Installation Manual CLIFC Fan & Coil Variable Speed General Description GENERAL DESCRIPTION FANS EQUIPMENT Totally Factory assembled within the unit all piping, wiring, and required controls for operation

More information

CHAPTER7. Base with Cutout for Sloped Front... 591 Support Bracket... 591 Bases for Sloped Front... 592 Wall-Mount Kit... 592

CHAPTER7. Base with Cutout for Sloped Front... 591 Support Bracket... 591 Bases for Sloped Front... 592 Wall-Mount Kit... 592 63.422.22 63.422.2600 HMI - Human-Machine Interface CHAPTER Human Machine Interface Chapter Contents HMI Product Selection Guide Overview HMI Product Selection Guide... 548 INLINE HMI System and Accessories

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air

More information

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES. QUIET-ONE Environmental Products 2000 Kickspace Heater Series Models: KS 2004, KS 2006 KS 2008, KS 2010 INSTALLATION OPERATING MAINTENANCE Please read these instructions thoroughly before beginning your

More information

FOXAIR 60/50 ALL MODELS

FOXAIR 60/50 ALL MODELS FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,

More information

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS RELATED SECTIONS: Section 27 00 00 General Requirements Section 27 02 00 Communication General Requirements Section 27 05 28 Pathways for Communications

More information

EXTRUDED HEAT SINKS FOR POWER SEMICONDUCTORS

EXTRUDED HEAT SINKS FOR POWER SEMICONDUCTORS WTS001_p26-49 6/14/07 10:56 AM Page 45 EXTRUDED HEAT SINS FOR POWER S 621/623 SERIES Low-Profile for All Metal-Case Power Semiconductors TO-3 Footprint Thermal Performance at Typical Load Standard Dimensions

More information

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service

More information

CABINET OPTIONS AND DESIGNATORS

CABINET OPTIONS AND DESIGNATORS CABINET OPTIONS AND DESIGNATORS Hinges: ~Stainless steel lift off Nuts and Bolts: ~ Stainless steel Hardware: ~ Handles and Corbin locks are stainless steel or zinc plated Windows: ~ Lexan Backboards:

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

Vigilant LED High Bay for Indoor and Outdoor Industrial Applications

Vigilant LED High Bay for Indoor and Outdoor Industrial Applications for Indoor and Outdoor Industrial Applications for Indoor and Outdoor Industrial Applications About Dialight Dialight (LSE: DIA.L) is leading the energy efficient LED lighting revolution around the world

More information

Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks

Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks 19-inch Industry Standard Rack Systems The trend to consolidation as a result of virtualization and optimization

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

Installation. Smart-UPS VT MGE Galaxy 3500. Maintenance Bypass Panel. 10-40 kva 400 V

Installation. Smart-UPS VT MGE Galaxy 3500. Maintenance Bypass Panel. 10-40 kva 400 V Installation Smart-UPS VT MGE Galaxy 3500 Maintenance Bypass Panel 10-40 kva 400 V Contents Safety.................................................. 1 Save these instructions...................................

More information

I/A Series HARDWARE Product Specifications. G50 Server Enclosure PSS 21H-2X50 B4 FEATURES

I/A Series HARDWARE Product Specifications. G50 Server Enclosure PSS 21H-2X50 B4 FEATURES I/A Series HARDWARE Product Specifications G50 Server Enclosure PSS 21H-2X50 B4 Note: Shown without Cable Base (Included) The I/A Series G50 Server Enclosure with front and rear access provides environmental

More information

Single Package Vertical Air Conditioners. Vert-I-Pak

Single Package Vertical Air Conditioners. Vert-I-Pak Single Package Vertical Air Conditioners Vert-I-Pak Installs easily in a closet for quiet operation and provides a more homelike appearance for your guests. THE EXPERTS IN ROOM AIR CONDITIONING A Better

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

PACKAGED TERMINAL AIR CONDITIONER (PTAC) / PACKAGED TERMINAL HEAT PUMP (PTHP) AND ACCESSORY INSTALLATION INSTRUCTIONS

PACKAGED TERMINAL AIR CONDITIONER (PTAC) / PACKAGED TERMINAL HEAT PUMP (PTHP) AND ACCESSORY INSTALLATION INSTRUCTIONS PACKAGED TERMINAL AIR CONDITIONER (PTAC) / PACKAGED TERMINAL HEAT PUMP (PTHP) AND ACCESSORY INSTALLATION INSTRUCTIONS PTAC/PTHP AND ACCESSORY SAFETY... PLANNING THE INSTALLATION... Typical Unit Components...

More information

K17.12 Door closers K17. Doors 01.09.2013

K17.12 Door closers K17. Doors 01.09.2013 K17 Doors K17.12 01.09.2013 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com Contents 1. OPTIC door closer TS40(V) with scissor

More information

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM D400E Data Module (60Hz) The EDGE D400E is designed to meet high power density requirements for both the HPC and Web Scale environments while

More information

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications Dialight Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications Case Study: Rockline Case Study (Manufacturing)

More information

ASCO SERIES 185 Power Transfer Switches

ASCO SERIES 185 Power Transfer Switches ASCO SERIES 185 Power Transfer Switches 4-hour protection no matter when trouble strikes ASCO Series 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... Your business or home from

More information

CELO5. User & Installation Manual. www.audac.eu

CELO5. User & Installation Manual. www.audac.eu CELO5 User & Installation Manual www.audac.eu 2 Introduction 5 High-end Slim Ceiling Speaker The CELO5 is the 5 version of AUDAC s CELO High-end Slim ceiling speaker series with an RMS power of 50 Watt

More information

SERVER ROOM CABINET INSTALLATION CONCEPTS

SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS ZPAS 169 EXAMPLES OF SERVER ROOMS PROJECTS WITH ZPAS CABINETS Data Box in the

More information

Cabinet Overview Frame Material & Construction. Shelves Fan Options Cable Trays Blank Panels Brush Cable Entry

Cabinet Overview Frame Material & Construction. Shelves Fan Options Cable Trays Blank Panels Brush Cable Entry i Q S E R I E S S P E C I F I C A T I O N S P a g e s 2-5 Cabinet Overview Frame Material & Construction Quality Assurance Freestanding Specifications i Q S E R I E S B A S I C C A B I N E T F R A M E

More information

STRONG AND RELIABLE WWW.BATKO.COM

STRONG AND RELIABLE WWW.BATKO.COM STRONG AND RELIABLE WWW.BATKO.COM MINIATURE CAMERA ENCLOSURES FB-1301 A discreet low-cost triangular corner housing for small rooms This very compact, triangular board camera housing is easy to install

More information

ARTS AND CRAFTS 10.1.0. 5410 (open) 5412 (doors) H : 84" Tote Tray Storage. Damp Storage. Tote Tray Storage. Notebook Board Storage, Doors

ARTS AND CRAFTS 10.1.0. 5410 (open) 5412 (doors) H : 84 Tote Tray Storage. Damp Storage. Tote Tray Storage. Notebook Board Storage, Doors Drawing Board Storage, Open Drawing Board Storage, Doors Drawing Board Storage Notebook Storage, Open 1670 D : 23.25" holds 32 drawing boards 1 shelf, adjustable on 1¼" increments maximum board height

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

French Door Refrigerator E23BC78IPS professional series

French Door Refrigerator E23BC78IPS professional series French Door Refrigerator E23BC78IPS professional series 23 CU. FT. COUNTER-DEPTH FRENCH DOOR REFRIGERATOR Custom Temp Drawer Enjoy the ultimate in versatility with 9 preset selections including White/Sparkling

More information

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing

More information

Remote Power Panels with Breakers

Remote Power Panels with Breakers Remote Power Panels with Breakers 8 Series Panels & Enclosures N/A N/A Remote power panels with breakers are available in two different sizes, each of which may be either surfacemounted or recess-mounted,

More information

Racks & Enclosures. Deliver. Design. Define. Three simple words that clearly describe how we approach a Data Center project.

Racks & Enclosures. Deliver. Design. Define. Three simple words that clearly describe how we approach a Data Center project. Three simple words that clearly describe how we approach a Data Center project. Eclipse Racks & Enclosures DELIVERING THE RIGHT INFRASTRUCTURE FOR YOUR MISSION-CRITICAL NEEDS SERVER RACKS & NETWORKING

More information

HARTING Ethernet Cabling 8-poles Overview

HARTING Ethernet Cabling 8-poles Overview Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs

More information

Rack installation instructions

Rack installation instructions Rack installation instructions Review the documentation that comes with the rack cabinet for safety and cabling information. Before you install the server in a rack cabinet, review the following guidelines:

More information

Unpacking, Installation, and Customization

Unpacking, Installation, and Customization Unpacking, Installation, and Customization NetShelter WX Enclosure AR100 AR100HD Contents Unpacking... 1 How to Unpack the Enclosure............................... 1 Please Recycle..........................................

More information