Contactors and Contactor Assemblies

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Contactors and Contactor Assemblies"

Transcription

1 Contactors and Contactor Assemblies SIRIUS Overview The contactor assemblies can be ordered as follows: Sizes S00 to S3 Fully wired and tested, open type, with mechanical and electrical interlock. 1 ) Sizes S00 to S12 As components for customer assembly. There is also a range of accessories (auxiliary switch blocks, surge suppressors, etc.) that must be ordered separately. For overload relays for motor protection, see section 3. The 3RA13 have screw connections and are available for screwing or snapping onto 35 mm standard mounting rails. The s and u approvals only apply to the complete contactor assemblies and not to the components for customer assembly. AC and IEC , EN (VDE 0660) horsepower rating at 460 V AC Size Order No. Contactor Mechanical interlock 2 ) Mechanical interlock 3 ) Mechanical interlock 4 ) Installation kit Fully wired and tested contactor HP A assembly 3 7 S00 3RT ) 3RA A 6 ) 3RA XB RT RA XB RT RA XB S0 3RT RA A 3RA B 3RA A 7 ) 3RA XB RT RA XB RT RA XB RT RA XB S2 3RT RA A 3RA B 3RA A 8 ) 3RA XB RT RA XB RT RA XB RT RA XB S3 3RT RA A 3RA B 3RA A 9 ) 3RA XB RT RA XB RT RA XB S6 3RT RA A 3RA A 10 ) RT RT S10 3RT RA A 3RA A 10 ) RT RT S12 3RT RA A 3RA A 10 ) RT10 76 For dimension drawings, see page 2/ /64 1) An additional dead interval of 50 ms is necessary on reversing at voltages > 500 V. 2) Laterally mountable with one auxiliary contact. 3) For front mounting with one auxiliary contact. 4) Laterally mountable without auxiliary contact. 5) Interlock must be ordered with installation kit. 6) Installation kit contains: mechanical interlock; 2 connecting clips for 2 contactors; wiring connectors on the top and bottom. 7) Installation kit contains: wiring connectors on the top and bottom. 8) Installation kit contains: 2 connecting clips for 2 contactors; wiring connectors on the top and bottom. 9) Installation kit contains: 2 connecting clips for 2 contactors; wiring connectors on the top and bottom. 10) Installation kit contains: wiring connector on the top and bottom.

2 SIRIUS Contactors and Contactor Assemblies Design Complete equipment assemblies The fully wired reversing contactor assemblies are suitable for use in any climate. They are safe from touch to DIN VDE 106 Part 100. The each consist of two contactors with identical ratings and one NC contact in the basic unit. The contactors are mechanically and electrically interlocked (NC contact interlock). The main and control circuits are wired according to the circuit diagrams on page 2/161. For motor protection, either 3RU11 overload relays for direct mounting or individual mounting or thermistor motor protection tripping units must be ordered separately. Components for customer assembly Installation kits for all sizes are available for customer assembly of reversing contactor assemblies. Contactors, overload relays, the mechanical interlock (as of size S0) and - for momentary-contact operation - auxiliary switch blocks for latching must be ordered separately. The following points should be noted: Size S00 For maintained-contact operation: use contactors with an NC contact in the basic unit for the electrical interlock. For momentary-contact operation: use contactors with an NC contact in the basic unit for the electrical interlock; in addition, an auxiliary switch block with at least one NO contact for latching is required per contactor. Sizes S0 to S3 For maintained-contact operation: the contactors have no auxiliary contact in the basic unit; NC contacts for the electrical interlock are therefore integrated in the mechanical interlock that can be mounted on the side of each contactor (one contact each for the left and right-hand contactors). For momentary-contact operation: the electrical interlock is the same as for maintained-contact operation; in addition, an auxiliary switch with one NO contact for latching is required per contactor. This contact can be snapped onto the top of the contactors. Alternatively, auxiliary switch blocks mounted on the side can be used; they must be fitted onto the outside of each contactor. If the front-mounted mechanical interlock is used for size S0 to S3 contactors, two location holes for single-pole auxiliary switch blocks are provided on the front of each S0 or S2 contactor, while three additional, single-pole auxiliary switch blocks can be snapped onto S3 contactors. The auxiliary switch complements per contactor stated on page 2/12 must not be exceeded. When size S2 and S3 contactors are combined with a frontmounted mechanical interlock, the 3RA B and 3RA B installation kits cannot be used. Sizes S6 to S12 To insert the mechanical interlock, the prestamped location holes positioned opposite on the contactor must be knocked out. The internal auxiliary contacts (up to 1 NO + 1 NC per contactor) can be used for the electrical interlock and latching. The mechanical interlock itself does not contain any auxiliary contacts. Additional auxiliary contacts can be used on the outside and front (on the front in the case of 3RT10) of the reversing contactor assembly. Principle of operation The operating times of the individual 3RT10 contactors are rated in such a way that no overlapping of the contact making and the arcing time between two contactors can occur on reversing, providing they are interlocked via their auxiliary switches (NC contact interlock) and the operating mechanisms. An additional dead interval of 50 ms is necessary on reversing if the individual contactors are used at voltages > 500 V. The operating times of the individual contactors are not affected by the mechanical interlock. Surge suppression Sizes S00 to S3 All can be fitted with RC elements or varistors for damping opening surges in the coil. As with the individual contactors, the surge suppressors can either be plugged onto the top of the contactors (S00) or fitted onto the coil terminals on the top or bottom (S0 to S3). Sizes S6 to S12 The contactors are fitted with varistors as standard. 2/65

3 Contactors and Contactor Assemblies SIRIUS Size S00 up to 5.5 kw Rated control supply voltage Horsepower ratings of three-phase motors 200 V 230 V 460 V 575 V Order No. Fully wired and tested contactor assembly 3 ) V, 50/60 Hz 3RA XB30-1AB V, 60 Hz 3RA XB30-1AK V, 60 Hz 3RA XB30-1AP V, 50/60 Hz 3RA XB30-1AB V, 60 Hz 3RA XB30-1AK V, 60 Hz 3RA XB30-1AP V, 50/60 Hz 3RA XB30-1AB V, 60 Hz 3RA XB30-1AK V, 60 Hz 3RA XB30-1AP DC 24 V 3RA XB30-1BB DC 24 V 3RA XB30-1BB DC 24 V 3RA XB30-1BB Accessory Order No. Page 13 Solder pin adapter 3RT KA1 2/51 14 mountable on the front 3RH /41 (only auxiliary switch blocks to DIN EN can be used) 16 Surge suppressor 3RT /47, 2/ Contactors, 3 HP 3RT RT / Contactors, 5 HP 3RT RT / Contactors, 7.5 HP 3RT RT / Installation kit 3RA A 2/71 The installation kit contains: Mechanical interlock 2 connecting clips for 2 contactors Wiring connectors on the top and bottom for connecting the main conducting paths, electrical interlock included 2 ), interruptible (NC contact interlock) 2/66 1) 3RT10 1. contactors with one NC contact in the basic unit are required for the electrical interlock. 2) The contactors integrated in the contactor assemblies have no unassigned auxiliary contacts.

4 SIRIUS Contactors and Contactor Assemblies Size S0 up to 15 HP Rated control supply voltage HP ratings of three-phase motors 200/208 V 230/240 V 460/480 V 575/600 V Order No. Fully wired and tested contactor assembly V, 50/60 Hz 3RA XB30-1AC V, 60 Hz 3RA XB30-1AK V, 60 Hz 3RA XB30-1AP V, 50/60 Hz 3RA XB30-1AC V, 60 Hz 3RA XB30-1AK V, 60 Hz 3RA XB30-1AP V, 50/60 Hz 3RA XB30-1AC V, 60 Hz 3RA XB30-1AK V, 60 Hz 3RA XB30-1AP V, 50/60 Hz 3RA XB30-1AC V, 60 Hz 3RA XB30-1AK V, 60 Hz 3RA XB30-1AP DC 24 V 3RA XB30-1BB DC 24 V 3RA XB30-1BB DC 24 V 3RA XB30-1BB DC 24 V 3RA XB30-1BB The connecting leads are not shown. Accessory Order No. Page mountable on the front 3RA A 2/70 mountable on the front 3RH CA.. 2/42 laterally mountable 3RH EA.. 2/43 Surge suppressor 3RT / Contactors, 5 HP 3RT RT / Contactors, 7.5 HP 3RT RT / Contactors, 10 HP 3RT RT / Contactors, 15 HP 3RT RT / laterally mountable 3RA B 2/70 Installation kit 3RA A 2/71 The installation kit contains wiring connectors on the top and bottom (they also form the mechanical connection between the contactors). 2/67

5 Contactors and Contactor Assemblies SIRIUS Size S2 up to 40 HP Rated control Fully wired and tested HP ratings of three-phase motors supply voltage 1 ) contactor assembly 200/208 V 230/240 V 460/480 V 575/600 V Order No V, 50/60 Hz 3RA XB30-1AC V, 60 Hz 3RA XB30-1AK V, 60 Hz 3RA XB30-1AP V, 50/60 Hz 3RA XB30-1AC V, 60 Hz 3RA XB30-1AK V, 60 Hz 3RA XB30-1AP V, 50/60 Hz 3RA XB30-1AC V, 60 Hz 3RA XB30-1AK V, 60 Hz 3RA XB30-1AP V, 50/60 Hz 3RA XB30-1AC V, 60 Hz 3RA XB30-1AK V, 60 Hz 3RA XB30-1AP DC 24 V 3RA XB30-1BB DC 24 V 3RA XB30-1BB DC 24 V 3RA XB30-1BB DC 24 V 3RA XB30-1BB The connecting leads are not shown. Accessory Order No. Page mountable on the front 3RA A 2/70 mountable on the front 3RH CA.. 2/42 laterally mountable 3RH EA.. 2/43 Surge suppressor 3RT /48 3RT Contactors, 20 HP 3RT RT / Contactors, 25 HP 3RT RT / Contactors, 30 HP 3RT RT / Contactors, 40 HP 3RT RT /18 4 laterally mountable 3RA B 2/ Installation kit 3RA A 2/71 The installation kit contains: connecting clips for 2 contactors with a clearance of 10 mm Wiring connectors on the top and bottom for connecting the main conducting paths 2/68

6 SIRIUS Contactors and Contactor Assemblies Size S3 up to 45 kw Rated control Fully wired and tested HP ratings of three-phase motors supply voltage contactor assembly 200/208 V 230/240 V 460/480 V 575/600 V Order No V, 50/60 Hz 3RA XB30-1AC V, 60 Hz 3RA XB30-1AK V, 60 Hz 3RA XB30-1AP V, 50/60 Hz 3RA XB30-1AC V, 60 Hz 3RA XB30-1AK V, 60 Hz 3RA XB30-1AP V, 50/60 Hz 3RA XB30-1AC V, 60 Hz 3RA XB30-1AK V, 60 Hz 3RA XB30-1AP DC 24 V 3RA XB30-1BB DC 24 V 3RA XB30-1BB DC 24 V 3RA XB30-1BB The connecting leads are not shown. Accessory Order No. Page mountable on the front 3RA A 2/70 mountable on the front 3RH CA.. 2/42 laterally mountable 3RH EA.. 2/43 Surge suppressor 3RT /48 3RT ) Coil voltage tolerance at 50 Hz: x U s at 60 Hz: x U s 1 2 Contactors, 50 HP 3RT RT / Contactors, 60 HP 3RT RT / Contactors, 75 HP 3RT RT /18 4 laterally mountable 3RA B 2/ Installation kit 3RA A 2/71 The installation kit contains: 5 2 connecting clips for 2 contactors with a clearance of 10 mm 6 Wiring connectors on the top and bottom 2/69

3RA13 Reversing Contactor Assemblies

3RA13 Reversing Contactor Assemblies 3RA3 Reversing Contactor Assemblies SIRIUS 3R Overview The 3RA3 reversing contactor assemblies can be ordered as follows:, open type, with mechanical and electrical interlock. ) As components for customer

More information

5,5 5,5 20-1 HKM11V HKM11X K1W12D01MC... LA1W12W. 01 1 0,32 5,5 5,5 20 1 - - HKM.. K1W12D10MC... LA1W12W. 10 1 0,32

5,5 5,5 20-1 HKM11V HKM11X K1W12D01MC... LA1W12W. 01 1 0,32 5,5 5,5 20 1 - - HKM.. K1W12D10MC... LA1W12W. 10 1 0,32 Mini Reversing Contactors, Mechanical Interlocked AC Operated Power Ratings Rated Aux. Contacts 2) Type Coil voltage 1) Current Built-in Additional 24 24V 50/60Hz 0 AC2, AC3 on left on right 230 220-230V

More information

SIRIUS Controls Contactors and Contactor Assemblies

SIRIUS Controls Contactors and Contactor Assemblies SIRIUS Controls Contactors and Contactor Assemblies / Introduction RT Power Contactors for Switching Motors / General data /5 RT0 contactors, -pole,... 5 HP RA, RA4 Contactor Assemblies RA Reversing Contactor

More information

DLA starters General information

DLA starters General information General information The construction of is based on ABB A Line contactors. The mounting plate, including a built-in A contactor, is designed to integrate an ABB manual motor starter type MS325. Starters

More information

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V, Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41

More information

Switching Devices Contactors and Contactor Assemblies Special Applications

Switching Devices Contactors and Contactor Assemblies Special Applications Switching Devices Contactors and Contactor Assemblies Special Applications Price groups PG 1B, 1H /2 Introduction Contactors for special applications / SIRIUS 3RT1 contactors for resistive loads (AC-1),

More information

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Reversing Contactors Open Type Version

Reversing Contactors Open Type Version BEM... A9...A40 VE5.1 BEM... A9...A40 E1112D1 VOA..-0M version >> VOA..-0M, VNA..-0M Reversing contactors... page /1 >> Reversing contactors in kit form... page /6 /0 ABB Control VOA..-0M, VNA..-0M A1

More information

Motor Starting Solutions

Motor Starting Solutions Application Guide Motor Starting Solutions Open Type Version In Kit Form Complete ange of Products and Accessories to Create all Motor Starter Types Manual motor starter Short-Circuit Protection... Type

More information

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No. RFV Key features: Compact and EN compliant RFV force guided relays Force guided contact mechanism (EN00 Type A TÜV approved) Contact configuration -pole (NO-NC, 3NO-NC) 6-pole (NO-NC, NO-NC, 3NO-3NC) Built-in

More information

Electric resistors for Roof Top ACTIVA

Electric resistors for Roof Top ACTIVA Electric resistors for Roof Top ACTIVA 045-090 Options and Accessories, Installation manual Ref.: N-40334_EN 0909 Index Index 1 Electric resistors for Roof top ACTIVA 045-090... 1 1.1 Electric resistor

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according

More information

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

More information

How can a charging station for electric vehicles be set up simply and safely?

How can a charging station for electric vehicles be set up simply and safely? SB18 Building > Electromobility > Charging Station Design How can a charging station for electric vehicles be set up simply and safely? Requirement In order to supply electric vehicles with electric power,

More information

Contactors Motor Protection Accessories

Contactors Motor Protection Accessories Main Catalogue Contactors Motor Protection Accessories Main Catalogue Contactors Motor Protection Accessories 1 2 3 4 5 6 Product Range A, AE, BC, EH, EK Contactors N and KC Contactor Relays Accessories

More information

PSR The compact range Description

PSR The compact range Description Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides

More information

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide - long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and

More information

ABB Motor Starter Solutions Contactors Motor Protection Contactors, Motor Pr Accessories otection, Accessories

ABB Motor Starter Solutions Contactors Motor Protection Contactors, Motor Pr Accessories otection, Accessories 3299, boul. J.B. Deschamps Lachine, QC CANADA H8T 3E4 Tel.: (514) 420-3100 Fax: (514) 420-3137 Web Site: www.abb.ca ABB Motor Starter Solutions ABB provides the complete solution to all your motor starting

More information

D-Line Contactors, Overload Relays and Accessories

D-Line Contactors, Overload Relays and Accessories D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

A.., AF.., 3-pole Contactors

A.., AF.., 3-pole Contactors A.., AF.., pole Contactors a.c. Circuit Switching Switching of phase Cage Motors M AC uti li za tion category When making, the mo tor cur rent is about 6 x I n. Breaking while the mo tor is run ning at

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Control Devices Catalogue. Control Devices. Preferred and Standard Products Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface

More information

Low Voltage Controls & Distribution

Low Voltage Controls & Distribution SIRIUS Datasheet 2009 Low Voltage Controls & Distribution Answers for industry. s Pressing, equipping, transporting. These functions run in many automated production environments. You ll find everything

More information

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data. Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated

More information

3NP, 3NJ4, 3NJ5 Fuse Switch Disconnectors

3NP, 3NJ4, 3NJ5 Fuse Switch Disconnectors 3NP, 3NJ4, 3NJ5 Fuse Switch Diss General data Application SENTRON 3NP4 and 3NP5 fuse switch diss are controls for the occasional manual switching/isolating of loads and distribution boards. They are able

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

60 Series - General purpose relays 6-10 A. Features

60 Series - General purpose relays 6-10 A. Features 60 Series - General purpose relays 6-10 A Features 60.12 60.13 Plug-in mount 10 A General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listing

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories s RT series Miniature Printed Circuit oard Relays, Sockets and ccessories pplied Coil Voltage (% of rated nom.) RT series (DC Coil) 6 mp PC oard Miniature Relay Meets VDE 0mm Spacing, KV Dielectric File

More information

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary

More information

Contactors - True DC Coil

Contactors - True DC Coil - True DC Coil Three Pole - Series C7 C7 Non-Reversing, Three Pole With True DC Coil, Series C7 (Open type only) ➊➍ Ratings for Switching C Motors (C2 / C3 / C4) Open Type I e [] uxiliary kw (5 Hz) UL/CS

More information

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2

More information

Schneider Electric. TeSys Vacuum Contactors. June. Building a New Electric World

Schneider Electric. TeSys Vacuum Contactors. June. Building a New Electric World TeSys Vacuum Contactors June 2002 Building a New Electric World Selection guide, characteristics Contactors 5 Selection guide Contactor size LC1-V160 LC1-V320 LC1-V610 For utilisation category AC-3 Maximum

More information

Manual Motor Starter MS 116 up to 16 A Technical Data

Manual Motor Starter MS 116 up to 16 A Technical Data Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates

More information

Thermal Circuit Breaker / Switch Series 3131

Thermal Circuit Breaker / Switch Series 3131 Description Combination of single pole circuit breaker and N/FF switch with soft-touch rocker actuation. Contoured rockers are available with a choice of colours and legends, with optional illumination.

More information

Relays & Sockets. RH Series Compact Power Relays. Part Number Selection

Relays & Sockets. RH Series Compact Power Relays. Part Number Selection RH Key features SPDT through PDT, 0A contacts Compact power type relays Miniature power relays with a large capacity 0A contact capacity Compact size saves space Contact SPDT DPDT PDT PDT RH Series Compact

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Panorama. Motor protection and control Manual motor starters, contactors and overload relays

Panorama. Motor protection and control Manual motor starters, contactors and overload relays Panorama Motor protection and control Manual motor starters, contactors and overload relays ABB sets a new standard in motor control and power switching Featuring AF technology as standard, the latest

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

Solid-State Timer H3G

Solid-State Timer H3G Solid-State Timer Low-Cost, Plug-In Timer with Large Switching Capacity Up to 7-amp switching capacity Choose SPDT or DPDT contact form 12 time ranges Fits standard 8-pin sockets Ideal replacement for

More information

Lighting contactors A9 A300

Lighting contactors A9 A300 Lighting contactors Lighting contactors A9 A00 Lighting Features CE mark Compact space saving design Standard auxiliary contact configurations: A9 - A40 1 NO or 1 NC A50 - A110 1 NO & 1 NC Additional

More information

A full featured model in one small package. Low input current, high switching capabilities

A full featured model in one small package. Low input current, high switching capabilities PIR6W Slim Interface Terminal Block Relays The Relpol PIR6W Slim Interface Terminal Block Relay is ideally compact, designed for a variety of high-density isolation and interposing applications. A full

More information

1 CO 10 A (5 mm pin pitch) 1 CO 10 A 3.5 mm pin pitch PCB or 95 Series socket mount. Copper side view. Pin length 5.3 mm for PCB or sockets

1 CO 10 A (5 mm pin pitch) 1 CO 10 A 3.5 mm pin pitch PCB or 95 Series socket mount. Copper side view. Pin length 5.3 mm for PCB or sockets 40 PCB/Plug-in relays from 8 to 16 40 Power relays 1 and 2 pole for direct PCB or socket mount Type 40.31 -- 1 CO 10 (3.5 mm pin pitch) Type 40.51 -- 1 CO 10 (5 mm pin pitch) Type 40.52 -- 2 CO 8 (5 mm

More information

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) 4 NC1 D09-D18 NC1 -D32 US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) Standards: UL508, CSA C22.2, IEC 60947, and CE Marked Integral DIN Rail & Base Mounting in One Compact

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

SWITCHGEAR. 4G cam switches

SWITCHGEAR. 4G cam switches SWITCHGEAR 164 4G cam switches ENERGY SAFELY SWITCHED 165 SWITCHGEAR 166 GENERAL INFORMATION 4G-series cam switches are low voltage switches, designed according to the latest knowledge about switchgear

More information

4291 & 4295 / Type 4291 Type 4295 & Resistor Discharge 15 amp to 175 amp. Varistor Discharge 50 amp to 350 amp

4291 & 4295 / Type 4291 Type 4295 & Resistor Discharge 15 amp to 175 amp. Varistor Discharge 50 amp to 350 amp Hubbell Industrial Controls, Inc. Euclid Full Voltage Magnet Controller Instructions/Parts Manual - September 2012, Replaces Dec. 2010 4291 & 4295 / 4296 Type 4291 Type 4295 & 4296 Varistor Discharge 50

More information

5SV Residual Current Protective Devices

5SV Residual Current Protective Devices s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201 Technical Catalogue Installation Contactors Type ESB abb ABB STOTZ-KONTAKT GmbH 1 CDC 10300 C001 ABB STOTZ-KONTAKT GmbH CDC 10300 C001 Low Voltage Products and Systems We ensure safety and comfort for

More information

Panorama. R contactors Control of AC and DC power circuits up to 5000 A

Panorama. R contactors Control of AC and DC power circuits up to 5000 A Panorama R contactors Control of AC and DC power circuits up to 5000 A R contactors Tailored to your needs With over 100 years of experience in control, ABB has designed its R contactors to meet the particular

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

55 SERIES. General purpose relays 7 to 10 A General purpose relays For printed circuit mounting. Type Type Type 55.

55 SERIES. General purpose relays 7 to 10 A General purpose relays For printed circuit mounting. Type Type Type 55. 55 General purpose relays 7 to 10 55 General purpose relays For printed circuit mounting 55.12 55.13 55.14 Type 55.12 -- 2 CO 10 Type 55.13 -- 3 CO 10 Type 55.14 -- 4 CO 7 C & DC coils Cadmium Free contacts

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW ADS8 IP54 Direct-On-Line Starter Technical Focus Replaces ADS7 Rated up to 9kW New ADS8 Motor Starter The new ADS8 range of motor starters replaces the successful ADS7 range which was introduced 20 years

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: ABB FRANCE ACTIVITE PROTECTION ET CONTROL 3 RUE JEAN PERRIN CS90009 69687 CHASSIEU CEDEX FRANCE This is to certify that representative samples of MOTOR CONTROLLERS, MAGNETIC See Addendum Pages

More information

2 pole, 10 A power contacts 8 pin plug-in

2 pole, 10 A power contacts 8 pin plug-in 60 General purpose relays 6-10 60 Plug-in mount 10 General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) C coils & DC coils UL Listing (certain relay/socket combinations)

More information

Accessories to PR A 28. Shunt trip Vc. Technical data. Dimensional drawing of VC - PR 60. Instructions guide for the mounting of ashunt trip VC-PR 60

Accessories to PR A 28. Shunt trip Vc. Technical data. Dimensional drawing of VC - PR 60. Instructions guide for the mounting of ashunt trip VC-PR 60 Shunt trip Vc accessories to the circuit-breaker RI 60, RI 60J, PRe 60, PRe 40 and modular switches RV 60... utilized for the tripping of circuit-breaker (modular switch) by means of outer source of voltage

More information

Plug-in relays Mini ISO relays

Plug-in relays Mini ISO relays Powertrain Systems Chassis Systems Safety Security Body Driver Information Convenience Description Features Limiting continuous current 70 A Dimensional characteristics and the functional allocation of

More information

Section 5. IEC Power Devices. www.geindustrial.com Control Catalog 5-1

Section 5. IEC Power Devices. www.geindustrial.com Control Catalog 5-1 Contactors Overview ()...5-3 Mini Contactors () Overview...5-4 Features and Benefits...5-5 Accessory Features...5-6 Product Offering...5-7 Product Number Selection Instructions...5-7 Product Descriptions...5-8

More information

40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52

40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52 Features 40.31 40.51 40.52 1 & 2 Pole relay range 40.31-1 Pole 10 A (3.5 mm pin pitch) 40.51-1 Pole 10 A (5 mm pin pitch) 40.52-2 Pole 8 A (5 mm pin pitch) PCB mount - direct or via PCB socket 35 mm rail

More information

Omega.com TM. RELAY-URM SERIES Universal Relay Module

Omega.com TM.    RELAY-URM SERIES Universal Relay Module Omega.com TM http://www.omega.com e-mail: info@omega.com RELAY-URM SERIES Universal Relay Module SPECIFICATIONS... 2 DESCRIPTION... 3 POWER CONNECTION... 3 INPUT CONNECTIONS Relays 1-4... 4 Figure 2:

More information

Low Voltage Switch Gear J7 SERIES

Low Voltage Switch Gear J7 SERIES Advanced Industrial Automation Low Voltage Switch Gear J7 SERIES minimum size, maximum performance Omron, a leading global manufacturer in Low Voltage Switch Gear, introduces the new J7 series of high-quality

More information

E-Series. Circuit Breaker

E-Series. Circuit Breaker E-Series Circuit Breaker The E-Series hydraulic/magnetic circuit breaker is ideally suited for higher current and voltage applications. It is UL listed and CSA certified for branch circuit protection,

More information

Circuit diagram. Inteded use. Function

Circuit diagram. Inteded use. Function SNA 4043 K SNA 4063 K SNA 4044 K SNA 4064 K Basic unit for emergency stop and guard door applications Basic unit as per EN 62061 and EN ISO 13849-1 For safety category 4 and stop category 0 Single or twin

More information

ELFA E90S MINI BREAKERS

ELFA E90S MINI BREAKERS ELFA E90S MINI BREAKERS - ELFA E90S SERIES UL Approved (UL1077) 10KA INTERUPTION CAPACITY OPTIONS FIELD KITS Auxiliary Contacts Alarm Contact Shunt Trip UV Trip Current Limiting Design (Class 3) 3 Different

More information

3RV Motor Starter Protectors up to 100 A

3RV Motor Starter Protectors up to 100 A General data Overview S0 motor 3RV1 motor are compact, current limiting motor which are optimized for load feeders. The motor are used for switching and protecting three-phase induction motors of up to

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information. Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Class 525/580 CONTENTS Description Page General characteristics............................................... 1 Circuit breaker......................................................

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

mecotron Safety relay ESTOP-2 For emergency stop monitoring

mecotron Safety relay ESTOP-2 For emergency stop monitoring E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated

More information

Power Supplies 3. SDN-P DIN Rail Series

Power Supplies 3. SDN-P DIN Rail Series SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.

More information

Electronic timer CT-TGD.12

Electronic timer CT-TGD.12 2CDC 251 098 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1 MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

Solid-State Timer H3G

Solid-State Timer H3G ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-11000(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : sales@ashalain.com Solid-State Timer Low-Cost, Plug-In

More information

Series 427. 1/16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Series 427. 1/16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS Series 427 1/16 DIN Multi-Mode Bar Graph Display Timer PRODUCT HIGHLIGHTS Digital Setting with 0.1% Accuracy Unique LED Bargraph Indicates Time Cycle in 20% Increments 8 Field Selectable Modes of Operation

More information

DC Alarm Kit K76-G0537 for HS670 and SL540/570/580 Operators

DC Alarm Kit K76-G0537 for HS670 and SL540/570/580 Operators DC Alarm Kit K6-G05 for HS60 and SL50/50/580 Operators CARTON INVENTORY Alarm with wire harness (1) Extra blue wire stripped on both sides (connects J1- to J1-15) (1) Wire ties () Flange (1-G058) (1) TOOLS

More information

Disconnect switches Non-fusible Fusible

Disconnect switches Non-fusible Fusible Disconnect switches Non-fusible Fusible Low voltage disconnect switches from ABB ABB is committed to offering high quality and innovative low voltage products. ABB s disconnect switch lines are no exception.

More information

E3 and E3 Plus Electronic Overload Relays with Integrated DeviceNet Communications

E3 and E3 Plus Electronic Overload Relays with Integrated DeviceNet Communications Specification Guide 1.0 General 1.01 The electronic overload relay shall be available in NEMA and IEC contactor mount configurations. 1.02 The electronic overload relay shall be capable of being applied

More information

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050 Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage

More information

SIB Enclosed Soft Start User Guide

SIB Enclosed Soft Start User Guide SIB Enclosed Soft Start User Guide (7.5kW~55kW) V1.0.0 Contents 1 Safety information...1 2 Technical Data...2 3 Operation...4 4 SIB circuit diagram...6 SIB Enclosed Soft Start User Guide 1 Safety information

More information

EU Declaration of Conformity

EU Declaration of Conformity Product: Name and address of the manufacturer: Rockwell Automation, Inc. 101 South nd Street Milwaukee, WI 5304 U.S.A. EU Declaration of Conformity IEC Contactors, Reversing Contactors and Accessories

More information

Contact expansion modules

Contact expansion modules Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts

More information

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules CHIEF EN TERPRISES INC. M a s t e r I n t e r n a t i o n a l D i s t r i b u t o r Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules M AS TER IN

More information

Classification Contact form Mounting method Terminals Rated voltage Model Equipped with operation indicator and diode to absorb coil surge.

Classification Contact form Mounting method Terminals Rated voltage Model Equipped with operation indicator and diode to absorb coil surge. Terminal Relay CSM_G6B-4 ND_DS_E_3_1 Compact Terminal Relay with 4 Independent Outputs Equipped with four G6B Mini-relays that are compact, highly sensitive, and highly resistant to dielectric surges,

More information

Series C H y d r a u l i c - M agnetic Circuit Breakers

Series C H y d r a u l i c - M agnetic Circuit Breakers Series C H y d r a u l i c - M agnetic Circuit Breakers Compact E-Frame circuit breaker Single and multipole VDE/UL/CSA recognized UL 489 listed to 10000 A International Approvals Ratings: 0.1 A to 100

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

Electronic Circuit Breaker ESS20-0...

Electronic Circuit Breaker ESS20-0... Description Electronic circuit breaker type ESS0-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode power supply. DC 4 V power supplies,

More information

Crane Control Class 9055

Crane Control Class 9055 Catalog 03 CONTENTS Description.....................................................Page pplication Data................................................... General Information and Pricing.......................................

More information

Switching Devices Contactors and Contactor Assemblies Contactor Relays and Relays

Switching Devices Contactors and Contactor Assemblies Contactor Relays and Relays Siemens AG 2013 Switching Devices Contactors and Contactor Assemblies Contactor Relays and Relays Price groups 41A, 41B, 41H, 4N1 /2 Introduction Contactor relays /4 SIRIUS 3RH2 contactor relays, 4- and

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

is then retained absolutely without interruption.

is then retained absolutely without interruption. Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection

More information

Timing relay module DC 24 110 V, programmable

Timing relay module DC 24 110 V, programmable Subject to technical modification 815000.00 Identification Type ZR6-5000.00 Product version Datasheet version 00 Use/Area of application Description The programmable timing relay consists of 2 changeover

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information