1 777 Bay Street, 2 nd Floor Toronto, Ontario, M5G 2E5 Tel: Fax: Web: Date of Authorization April 26, 2007 BMEC Authorization Number BMEC Application BMEC A AUTHORIZATION REPORT : Remote Non-Destructive Pipe Restoration Process 1. Applicant 2. Manufacturing Nu Flow Technologies 2000 Inc Thornton Road South Oshawa, Ontario L1J 7E Thornton Road South Oshawa, Ontario L1J 7E2 Tel: Fax: Web: 3. Description The, Remote Non-Destructive Pipe Restoration Process (The A Nu Flow System ) is intended for the restoration of metallic potable water pipes, specifically galvanized metal, copper, and stainless steel. The can repair pipes 12.7 mm (1/2 ) in diameter to 150 mm (6 ) in diameter. The, using existing access points along the water line riser, cleans the pipes with air pressure and a garnet abrasive grit. After removing the abrasive grit from the cleaned pipes, air pressure is used to test the lines for leaks and a video scope is employed to visually examine the cleaned surfaces on a sample basis. Air pressure is utilized to apply the two component NSF approved APL 2000 epoxy, which cures in 24 hours. Upon completion, a final pressure test is conducted to verify that the system is leak free. The performance level of the restored pipe is not less than that which existed prior to the application of the. Page 1 of 6

2 4. Authorization Requested The applicant sought a Building Materials Evaluation Commission (BMEC) authorization for the as an alternative to repairing potable metallic water pipes in existing buildings, as required by Division B, Section 7.2. AMaterials and and Division B, Article Extension, Material Alteration or Repair of Ontario s 2006 Building Code. 5. Assessment Reports and assessment provided by the applicant demonstrate that if the Nu Flow System is constructed, installed, operated, maintained and monitored in accordance with the limitations of the manufacturer specifications and conditions stated in this authorization, a level of performance equivalent to that required by the Ontario s 2006 Building Code will be provided. The following are reports that were submitted and reviewed, but were not limited to: 1. Nu Flow Technologies 2000 Inc. Equipment Description List. 2. Nu Flow Technologies 2000 Inc. Potable Water Training and Installation Manual. 3. Nu Flow Technologies 2000 Inc. Sample Survey Forms, Pre-Bid Check List and Bid Forms. 4. Nu Flow Technologies 2000 Inc. Sample Quality Control Work Sheets 5. CRT Laboratories, Inc. Test Report IAPMO IGC : Internal Pipe Epoxy Barrier Coating Material for Application in Pressurized (Closed) Metallic Water Piping System, ANSI/NSF Standard 61, dated July 18, CRT Laboratories, Inc. Test Report ANSI/AWWA C standard for liquid epoxy Coating System for the Interior and Exterior of Steel Water Pipelines, dated July 18, Certification NSF/ANSI Standard 61 Drinking Water System Components Health Effects, dated August 26, Certification, IAPMO Research and Testing Inc. Nu Flow Potable water Stem #700 Dated November Fact Sheet from the Navy Pollution Prevention Conference on the Restoration if Drinking Water Piping with Nontoxic Epoxy Lining, dated June 6, Nu Flow Technologies 2000 Inc. Quality Control and Assurance Manual. 11. Certification, IAPMO Research and Testing Inc. Nu Flow Potable Water System #7000, dated November Page 2 of 6

3 12. Nu Flow Technologies 2000 Inc. Usage and Limitations. 13. Nu Flow Technologies 2000 Inc. Potable Water Training and Installation Manual. 14. Material Safety Data Sheet Product ID LA Nu Flow Technologies 2000 Inc. Warranty 6. Authorization The is authorized as an alternative to repairing potable metallic water pipes in existing buildings, as required by Division B, Section 7.2. AMaterials and and Division B, Article Extension, Material Alteration or Repair of Ontario s 2006 Building Code, all other requirements pertaining to the design, installation, and construction are subject to the requirements of Ontario s 2006 Building Code, and subject to the following terms and conditions: Note 1: If a conflict arises between this document and the provisions of the documents listed below, the most restrictive provision shall apply. A. Specific Terms and Conditions 1. This authorization is valid only for Nu Flow Technologies 2000 Inc. s Nu Flow System. 2. The shall be installed only by installers who are trained and approved by Nu Flow Technologies 2000 Inc. 3. Nu Flow Technologies 2000 Inc. s shall provide field training to all installers, before the installer uses this process, and such training will be delivered by an experienced technician approved by Nu Flow Technologies 2000 Inc. 4. shall be installed in accordance with Nu Flow Technologies 2000 Inc. s installation manuals. 5. The shall be used only in galvanized steel, copper, and stainless steel potable water pipes of 12.7 mm (1/2 ) in diameter to 150 mm (6 ) in diameter, and in single pipe segments up to 152 m (500-0 ) in length, varying in length with pipe diameter in accordance with Nu Flow Technologies 2000 Inc. s Potable Water Training and Installation Manual. 6. The shall not be used in fire protection systems, such as standpipe and sprinkler systems. 7. The APL 2000 epoxy shall be certified to the ANSI/NSF Drinking Water System Components Health Effects. Page 3 of 6

4 8. Confirmation that APL 2000 epoxy has maintained its certification to ANSI/NSF shall form a part of the permit documents to be submitted to the chief building official. 9. The thickness of the epoxy coating shall be determined by the epoxy manufacturer process instructions. The reduction in pipe diameter from the coating should be considered minimal and not essential for the flows in the pipes. 10. The curing process shall be supervised at all times by Nu Flow Technologies 2000 Inc. in accordance with Nu Flow Technologies 2000 Inc. s installation manuals. 11. All materials including the pipe cleaning and the two-component epoxy coating equipment used in the shall be supplied by Nu Flow Technologies 2000 Inc. and shall be handled in accordance with the manufacturer=s specifications. 12. Trained and authorized Nu Flow Technologies 2000 Inc. personnel, in accordance with the Nu Flow Technologies 2000 Inc. s instruction manuals shall, upon completion of the work or segment of the work, perform a visual inspection, on a sample basis, using a video scope to ensure the continuity and integrity of the applied lining. 13. Upon completion of the work or a segment of the work, the New Flow System installation shall be tested in accordance with the provisions of Division B, Subsection Testing of Potable Water Systems of Ontario s 2006 Building Code. 14. In addition to further documentation that may be requested, Nu Flow Technologies 2000 Inc. shall provide completed copies of the following reports to the chief building official and the building owner for each installation: (a) Flow Test Chart before (b) Daily Epoxy Check List (c) Flow Test Chart after (d) Post Job Check List (e) Closing Form (f) Material Safety Data Sheet Product ID LA8344 (g) Warranty Certificate 15. Non-removable stickers or labels recording the following information shall be applied near the water shut off valve on each riser treated; (a) a name and telephone label - identifying Nu Flow Technologies 2000 Inc. as having treated the pipe and including the phone number to call for information, (b) a warning - that the pipe has been coated with an epoxy lining, and (c) warning - not to torch, not to solder and to use pressure fittings only. Page 4 of 6

5 B. General Conditions 1. The use of the s and as described in the specific terms and conditions set out in 6.A. must comply with the Building Code Act, 1992 (the as amended or re-enacted from time to time and except as specifically authorized. 2. A copy of this Authorization shall accompany each application for a building permit and shall be maintained on the site of the construction with the building permit. 3. The Applicant named in Part 1 hereof shall promptly notify the BMEC of: (a) (b) the failure of the Applicant, or of the material, system or building design that is the subject matter of this Authorization, to comply with any of the terms and conditions set out in 6.A. above; or the occurrence of any of the events described in conditions 6.B.4.(a) and (b)(ii) below. 4. The BMEC may amend or revoke this Authorization where it determines that: (a) any change has been made to: (i) the material, system or building design that is the subject matter of this Authorization; (ii) the address of the applicant specified in Part 1 of this Authorization; or, (iii) the ownership of the applicant specified in Part 1 of this Authorization. (b) the use of the material, system or building design authorized herein; (i) does not comply with the Act any relevant legislation as they may be amended or re-enacted from time to time; or (ii) provides an unsatisfactory level of performance, in situ. (c) the Applicant, or the material, system or building design that is the subject matter of this Authorization, has failed to comply with any of the terms and conditions set out in this Authorization; or Page 5 of 6

6 (d) any provision of Ontario s 2006 Building Code relevant to this Authorization has been amended or remade. 5. Where the BMEC receives additional information concerning the material, system or building design authorized herein, the BMEC may review this Authorization and the BMEC may after the review amend or revoke this Authorization as in the opinion of the BMEC may be necessary. Dated at Toronto this 26 day of April BUILDING MATERIALS EVALUATION COMMISSION Edward Link, P. Eng. Chair, Building Materials Evaluation Commission Page 6 of 6

Date of Authorization November 30, 2006 BMEC Authorization Number 06-09-329 BMEC Application BMEC A2006-11. AUTHORIZATION REPORT The AcornVac System

Date of Authorization November 30, 2006 BMEC Authorization Number 06-09-329 BMEC Application BMEC A2006-11. AUTHORIZATION REPORT The AcornVac System 777 Bay Street, 2 nd Floor Toronto, Ontario, M5G 2E5 Tel: 416 585 4234 Fax: 416 585 7531 Web: www.obc.mah.gov.on. Date of Authorization BMEC Authorization Number 06-09-329 BMEC Application BMEC A2006-11

More information

DIVISION: 22 00 00 PLUMBING SECTION: 22 11 16 DOMESTIC WATER PIPING REPORT HOLDER: CURAFLO IP LLC 4035 E. OASIS STREET MESA, AZ 85215

DIVISION: 22 00 00 PLUMBING SECTION: 22 11 16 DOMESTIC WATER PIPING REPORT HOLDER: CURAFLO IP LLC 4035 E. OASIS STREET MESA, AZ 85215 0 ICC ES Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted PMG 1057 Valid: 02/15 to 02/16 DIVISION: 22 00 00 PLUMBING SECTION: 22 11 16 DOMESTIC WATER PIPING

More information

BUILDING MATERIALS EVALUATION COMMISSION (BMEC) AUTHORIZATION REPORT

BUILDING MATERIALS EVALUATION COMMISSION (BMEC) AUTHORIZATION REPORT BUILDING MATERIALS EVALUATION COMMISSION (BMEC) AUTHORIZATION REPORT DATE OF AUTHORIZATION July 26, 2001 BMEC REFERENCE BMEC # 01-11-263 BMEC APPLICATION # BMEC # A2001-13 TYCO FIRE PRODUCTS CENTRAL MODEL

More information

Date of Authorization March 25, 2010 BMEC Authorization Number 10-02-349 BMEC Application A2008-01 BMEC Expiration Date March 26, 2015

Date of Authorization March 25, 2010 BMEC Authorization Number 10-02-349 BMEC Application A2008-01 BMEC Expiration Date March 26, 2015 777 Bay Street, 2 nd Floor 777, rue Bay, 2 e etage Toronto, Ontario, M5G 2E5 Toronto, Ontario, M5G 2E5 T: 416 585 7531 T: 416 585 4234 F: 416 585 4234 TC: 416 585 7531 W: www.ontario.ca/buildingcode/ W:

More information

POLYURETHANE LINING AND COATING ON PIPE RAW WATER

POLYURETHANE LINING AND COATING ON PIPE RAW WATER POLYURETHANE LINING AND COATING ON PIPE RAW WATER PART 1 -- GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents. 1.2

More information

SMALL GAS OPERATOR OPERATION AND MAINTENANCE PLAN

SMALL GAS OPERATOR OPERATION AND MAINTENANCE PLAN SMALL GAS OPERATOR OPERATION AND MAINTENANCE PLAN Facility Name: Address: QUALIFIED PERSONNEL All tasks shall be completed by a person that is qualified to that task (see operators qualification of individuals

More information

A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents.

A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents. POLYURETHANE COATING ON STEEL PIPE PART 1 -- GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents. 1.2 REFERENCE SPECIFICATIONS,

More information

TORONTO MUNICIPAL CODE CHAPTER 470, FIRE SAFETY BOXES. Chapter 470 FIRE SAFETY BOXES

TORONTO MUNICIPAL CODE CHAPTER 470, FIRE SAFETY BOXES. Chapter 470 FIRE SAFETY BOXES Chapter 470 FIRE SAFETY BOXES 470-1. Interpretation. 470-2. Administration. 470-3. Fire safety box and lock box. 470-4. One fire safety box and one lock box. 470-5. Location. 470-6. Contents. 470-7. Service

More information

Where life interacts with infrastructure.

Where life interacts with infrastructure. Where life interacts with infrastructure. Nu Flow Technologies began as a new technology company in 1998, manufacturing and installing trenchless drain and sewer lining solutions. Today, Nu Flow Technologies

More information

STANDARD SPECIFICATIONS SECTION 02512 CLEANING AND LINING WATER MAINS

STANDARD SPECIFICATIONS SECTION 02512 CLEANING AND LINING WATER MAINS STANDARD SPECIFICATIONS SECTION 02512 CLEANING AND LINING WATER MAINS PART 1 GENERAL 1.1 DESCRIPTION A. Section includes requirements for cleaning and lining existing cast iron and ductile iron water mains

More information

The Pipelines Regulations, 2000

The Pipelines Regulations, 2000 PIPELINES, 2000 P-12.1 REG 1 1 The Pipelines Regulations, 2000 being Chapter P-12.1 Reg 1 (effective April 1, 2000) as amended by the Statutes of Saskatchewan, 2014, c.21. NOTE: This consolidation is not

More information

The Embassy of the United States of America invites you to submit an offer for supply and install the following A/Cs:

The Embassy of the United States of America invites you to submit an offer for supply and install the following A/Cs: RFQ number PR4877728 The Embassy of the United States of America invites you to submit an offer for supply and install the following A/Cs: A- Supplying and installing 30 high wall A/C split unit 3HP- 24,000

More information

CATHODIC PROTECTION SPECIFICATION

CATHODIC PROTECTION SPECIFICATION CATHODIC PROTECTION SPECIFICATION AUTOMATICALLY CONTROLLED IMPRESSED CURRENT CATHODIC PROTECTION SYSTEM FOR THE INTERIOR OF STEEL WATER TANKS A. SCOPE The cathodic protection design/install constructor

More information

Engineering Specifications

Engineering Specifications PUREFLOW PEX PRODUCTS PART 1 GENERAL 1.1 SUMMARY 1.1.1 This specification covers Branch & Main, Parallel Water Distribution Systems (MANABLOC), Cross-linked Polyethylene tubing and fittings using PEX Press

More information

B. In the event of conflicts between specifications this is the order of precedence:

B. In the event of conflicts between specifications this is the order of precedence: PART 1 GENERAL 1.1 SCOPE: A. This section includes the materials, equipment, procedures, and requirements to disinfect new and repaired water mains to acceptable levels as provided by the State of Oregon

More information

SAN ANTONIO WATER SYSTEM SPECIFICATIONS FOR DRY-BARREL FIRE HYDRANTS ANSI/AWWA C502-05 Revised February 2013

SAN ANTONIO WATER SYSTEM SPECIFICATIONS FOR DRY-BARREL FIRE HYDRANTS ANSI/AWWA C502-05 Revised February 2013 21-30 SAN ANTONIO WATER SYSTEM SPECIFICATIONS FOR DRY-BARREL FIRE HYDRANTS ANSI/AWWA C502-05 Revised February 2013 1. SCOPE This product specification covers post-type, dry-barrel fire hydrants with compression

More information

Superior Pipe Restoration Solutions. Proven, state-of-the-art technology that saves money, time and inconvenience. belcopipe.com

Superior Pipe Restoration Solutions. Proven, state-of-the-art technology that saves money, time and inconvenience. belcopipe.com Superior Pipe Restoration Solutions Proven, state-of-the-art technology that saves money, time and inconvenience. belcopipe.com About Us Belco Pipe Restoration was founded with the concept of using British

More information

SECTION DISINFECTION OF WATER DISTRIBUTION SYSTEMS

SECTION DISINFECTION OF WATER DISTRIBUTION SYSTEMS SECTION 02501 DISINFECTION OF WATER DISTRIBUTION SYSTEMS PART 1 GENERAL 2.1 SECTION INCLUDES A. Procedures for disinfecting new and repaired water distribution systems. All new water mains and repairs

More information

Fire Alarm System Monitoring, a Primer for the Property Owner David Duggan, 2005

Fire Alarm System Monitoring, a Primer for the Property Owner David Duggan, 2005 Fire Alarm System Monitoring, a Primer for the Property Owner David Duggan, 2005 Problem: How does a property owner / manager know when a fire alarm system is required for his premises, and just as important,

More information

AMERICAN SOCIETY OF CERTIFIED ENGINEERING TECHNICIANS

AMERICAN SOCIETY OF CERTIFIED ENGINEERING TECHNICIANS GREEN TAG/RED TAG AMERICAN SOCIETY OF CERTIFIED ENGINEERING TECHNICIANS ORLANDO CHAPTER ORLANDO, FL February 7, 2013 2012 FLORIDA STATUTES 633.082 Inspection of fire control systems, fire hydrants, and

More information

Recent outbreaks of pinhole leaks nationally are a significant issue. Figure 1.1 shows the

Recent outbreaks of pinhole leaks nationally are a significant issue. Figure 1.1 shows the CHAPTER 1 - INTRODUCTION 1. 1 Motivation Recent outbreaks of pinhole leaks nationally are a significant issue. Figure 1.1 shows the national distribution of pinhole leaks based on the data gathered by

More information

Section Four: Linings and Coatings

Section Four: Linings and Coatings Section Four: Linings and Coatings SPIRALWELD PIPE The majority of steel water pipe furnished today is specified to be provided with both an interior lining and an exterior coating. AMERICAN offers a wide

More information

MERCER ISLAND FIRE DEPARTMENT FIRE COMMERCIAL SPRINKLER STANDARDS

MERCER ISLAND FIRE DEPARTMENT FIRE COMMERCIAL SPRINKLER STANDARDS MERCER ISLAND FIRE DEPARTMENT FIRE COMMERCIAL SPRINKLER STANDARDS COMMERCIAL FIRE SPRINKLER SYSTEMS Page 1-5 SCOPE: Fire sprinkler systems in the City of Mercer Island shall meet the criteria as set forth

More information

Overview of Hotel Fire Safety Requirements

Overview of Hotel Fire Safety Requirements Overview of Hotel Fire Safety Requirements in the Fire Code Susan Clarke, P.Eng. Office of the Fire Marshal - January 10, 2012 1 Agenda Regulation History - Hotels Fire Code Overview (Parts 1 to 8) Defined

More information

Fire Alarm System Monitoring - CAN/ULC-S561-03

Fire Alarm System Monitoring - CAN/ULC-S561-03 Fire Alarm System Monitoring - CAN/ULC-S561-03 Brian McBain ULC Regulatory Services May 4, 2011 Copyright 1995-2007 Underwriters' Laboratories of Canada. All rights reserved. No portion of this material

More information

ACCREDITATION OF OWNER/USER SELF-INSPECTION REPAIR PROGRAM

ACCREDITATION OF OWNER/USER SELF-INSPECTION REPAIR PROGRAM ACCREDITATION OF OWNER/USER SELF-INSPECTION REPAIR PROGRAM TSSA GUIDE FOR REVIEW TEAMS The Technical Standards and Safety Authority Boilers and Pressure Vessels Safety Division 3300 Bloor Street West 14th

More information

Vertical & Horizontal Bladder Tanks Models MTB-A

Vertical & Horizontal Bladder Tanks Models MTB-A DATA SHEET Vertical & Horizontal Bladder Tanks Models MTB-A General Description The SKUM MTB-A bladder tank is a steel pressure vessel which stores a foam concentrate contained within an elastomeric bladder.

More information

Owner-User Pressure Equipment Integrity Management Requirements

Owner-User Pressure Equipment Integrity Management Requirements the pressure equipment safety authority Owner-User Pressure Equipment Integrity Management Requirements AB-512 Edition 2, Revision 0 Issued 2015-06-25 Owner-user Pressure Equipment Integrity Management

More information

Proposed New City of Toronto Water Supply By-law CONTENTS. Water Supply By-law. Index of Fee Schedules A, B, C. Orders Fines Tickets (reference list)

Proposed New City of Toronto Water Supply By-law CONTENTS. Water Supply By-law. Index of Fee Schedules A, B, C. Orders Fines Tickets (reference list) Proposed New City of Toronto Water Supply By-law CONTENTS Water Supply By-law Index of Fee Schedules A, B, C Schedule of Fines Summary General plus D, E, F Orders Fines Tickets (reference list) Backflow

More information

DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Environmental Cleanup and Brownfields. Storage Tank Modification and Maintenance Issues

DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Environmental Cleanup and Brownfields. Storage Tank Modification and Maintenance Issues DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Environmental Cleanup and Brownfields DOCUMENT NUMBER: 263-0900-011 TITLE: Storage Tank Modification and Maintenance Issues EFFECTIVE DATE: March 29, 2014

More information

HVAC Super Pro FAQ. Can HVAC SUPER PRO be used on both hard and soft copper and aluminum tubing?

HVAC Super Pro FAQ. Can HVAC SUPER PRO be used on both hard and soft copper and aluminum tubing? HVAC Super Pro FAQ Application What is the working time for HVAC SUPER PRO? HVAC SUPER PRO can be left on the tubing and connector for several minutes, but when the tubing is inserted into the connector

More information

Design & Construction Standards, Revised January 2013 5.21.10-1

Design & Construction Standards, Revised January 2013 5.21.10-1 PART 1 GENERAL 1.01 Scope of Standard A. This standard provides general requirements of The University of Texas at Austin for the design and construction of standpipe systems to include combination standpipe

More information

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2 STANDARD for Plumbing, Heating, Hot Water, Cold Water & Electrical work undertaken by owners within the building known as Sussex Lodge London W2 & 16 Stanhope Terrace London W2 BPME Consulting Engineers

More information

TORONTO MUNICIPAL CODE CHAPTER 851, WATER SUPPLY. Chapter 851 WATER SUPPLY

TORONTO MUNICIPAL CODE CHAPTER 851, WATER SUPPLY. Chapter 851 WATER SUPPLY Chapter 851 WATER SUPPLY 851-1. Definitions. 851-2. Administration. 851-3. Use and receipt of water. 851-4. Water service connections. 851-5. Metering of water. 851-6. Water meter inspection. 851-7. Maintenance.

More information

STATEMENT OF WORK (SOW) On-Call Certified Welding Inspections and Nondestructive Testing

STATEMENT OF WORK (SOW) On-Call Certified Welding Inspections and Nondestructive Testing 1.0 INTRODUCTION Colorado Springs Utilities (UTILITIES) is seeking qualified firms to provide verification welding inspection services, nondestructive testing services, and technical reporting to Colorado

More information

ATTACHMENT 3: SPECIFICATION FOR SEWER CLEANING

ATTACHMENT 3: SPECIFICATION FOR SEWER CLEANING ATTACHMENT 3: SPECIFICATION FOR SEWER CLEANING 1.0 General 1.1 The work covered by this section consists of providing all labor, equipment, material and supplies, insurance, accessories, tools, transportation,

More information

SECTION 07 61 13 STANDING SEAM METAL ROOFING

SECTION 07 61 13 STANDING SEAM METAL ROOFING SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced

More information

FIRE SPRINKLER SYSTEM SUPERVISORY SERVICE User s Guide (DamarNet RAR Service)

FIRE SPRINKLER SYSTEM SUPERVISORY SERVICE User s Guide (DamarNet RAR Service) FIRE SPRINKLER SYSTEM SUPERVISORY SERVICE User s Guide (DamarNet RAR Service) The information provided in this user guide pertains to fire suppression sprinkler system monitoring service provided over

More information

DEPARTMENT OF CONSUMER AND INDUSTRY SERVICES DIRECTOR'S OFFICE

DEPARTMENT OF CONSUMER AND INDUSTRY SERVICES DIRECTOR'S OFFICE DEPARTMENT OF CONSUMER AND INDUSTRY SERVICES DIRECTOR'S OFFICE CERTIFICATION OF FIRMS FOR FIRE ALARM SYSTEMS AND FIRE SUPPRESSION SYSTEMS IN STATE-REGULATED FACILITIES (By authority conferred on the state

More information

Price List January 1, 2015

Price List January 1, 2015 Price List January 1, 2015 Cement Lined Price List Certification and General Installation Certification All Ductile Iron Spooling manufactured by is made in accordance with current ANSI/AWWA- C115/A21.15

More information

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES AIR RELEASE, CLEANOUT, AND SEWER MANHOLES **From Hartford IM BLDG(10) DESCRIPTION. This work shall consist of the construction of air release, cleanout, and sanitary sewer manholes; and the furnishing

More information

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1 KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1 PART 1 - GENERAL 1.01 RELATED DOCUMENTS: SECTION 16050 A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1

More information

Amendment 1 Preliminary Engineering Report for the City of Salida

Amendment 1 Preliminary Engineering Report for the City of Salida Amendment 1 Preliminary Engineering Report for the City of Salida Galleries Water Tank Rehabilitation Project February 11, 2010 Prepared by 1.0 Executive Summary The work of this Preliminary Engineering

More information

Township of Enniskillen. Asset Management Plan

Township of Enniskillen. Asset Management Plan Township of Enniskillen Asset Management Plan 2014 1 TABLE OF CONTENTS Page A. Introduction 3 B. State of Local Infrastructure 4 C. Desired Levels of Service 7 D. Asset Management Strategy 8 E. Financing

More information

Introduction to Nu Flow

Introduction to Nu Flow Introduction to Nu Flow About Nu Flow Nu Flow technologies began as a new technology company in 1998, manufacturing and installing trenchless drain and sewer lining solutions. Today, Nu Flow technologies

More information

NFPA 25 FAQs. 1. When inspecting an old system (60 years or older), when/where does NFPA 25 require a system to be upgraded to present standards?

NFPA 25 FAQs. 1. When inspecting an old system (60 years or older), when/where does NFPA 25 require a system to be upgraded to present standards? NFPA 25 FAQs Responses to FAQs are prepared by NFPA technical staff to assist users in reading and understanding NFPA codes and standards. The responses, however, are not Formal Interpretations issued

More information

Enclosures 1-866-338-0988. DuraSystems Barriers, Inc. www.durasystems.com Email: sales@durasystems.com. The Passive Fire Protection Specialists

Enclosures 1-866-338-0988. DuraSystems Barriers, Inc. www.durasystems.com Email: sales@durasystems.com. The Passive Fire Protection Specialists Enclosures Sturdy single and double wall fire protection construction Impact resistant Fast & easy installation Pre-manufactured and modular Available in galvanized, stainless steel & other specialty metals

More information

Small Business Permit Service

Small Business Permit Service Small Business Permit Service Building Permit Requirements For a Unit Finish or Interior Alteration Industrial, Commercial or Institutional Occupancies Building Permit Application The following documents

More information

MODEL: UC 150 ICE DISPENSER

MODEL: UC 150 ICE DISPENSER MODEL: UC 150 ICE DISPENSER Installation Manual Revision Date: August, 1999 Publication Number: 620917312 Revision Date: August 3, 2010 Revision: C Visit the IMI Cornelius web site at www.cornelius.com

More information

Canada Pipe Lining Technology. www.cpltech.com

Canada Pipe Lining Technology. www.cpltech.com Canada Pipe Lining Technology www.cpltech.com CB Canada Pipe Lini CB SERVICES ng Technologies 4 SERVICES Canada Pipe Lining Technology FEBRUARY 2013 The Canadian Business Journal 5 Plumbing and water transportation

More information

EXHIBIT A SCOPE OF WORK

EXHIBIT A SCOPE OF WORK EXHIBIT A SCOPE OF WORK 1. (Contractor) shall provide fire alarm system maintenance/repair/testing services as described herein to the California Department of Veterans Affairs (hereinafter CDVA, CalVet,

More information

AMENDED ENVIRONMENTAL COMPLIANCE APPROVAL NUMBER 2152-A3YN6H Issue Date: November 13, 2015 L. & G. General Auto Body Limited. ite4656 Yonge Street

AMENDED ENVIRONMENTAL COMPLIANCE APPROVAL NUMBER 2152-A3YN6H Issue Date: November 13, 2015 L. & G. General Auto Body Limited. ite4656 Yonge Street Ministry of the Environment and Climate Change Ministère de l Environnement et de l Action en matière de changement climatique AMENDED ENVIRONMENTAL COMPLIANCE APPROVAL NUMBER 2152-A3YN6H Issue Date: November

More information

PLEASE NOTE. For more information concerning the history of these regulations, please see the Table of Regulations.

PLEASE NOTE. For more information concerning the history of these regulations, please see the Table of Regulations. PLEASE NOTE This document, prepared by the Legislative Counsel Office, is an office consolidation of this regulation, current to June 1, 2014. It is intended for information and reference purposes only.

More information

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description Worldwide Contacts www.tyco-fire.com Model F thru F3 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description The Mulsifyre Nozzles are open (nonautomatic) nozzles and they are designed

More information

WATERMAIN Testing Procedures. shall be the Consulting Engineer, or their designate.

WATERMAIN Testing Procedures. shall be the Consulting Engineer, or their designate. INTRODUCTION Scope WATERMAIN Testing Procedures This procedure covers the cleaning, disinfection, hydrostatic testing and sampling of watermains. Unless specified otherwise this procedure applies to all

More information

Replacement of Heat System Components

Replacement of Heat System Components STATEMENT OF WORK FOR Replacement of Heat System Components At Warehouse Takoraudantie 4 08/17/2013 REV 8-24-13 Project 2013-021 Page 1 of 6 1.0 INTRODUCTION 1.1 Overview: The U.S. Embassy Helsinki has

More information

FIRING RANGE PHASE 1 DESIGN 224500-1

FIRING RANGE PHASE 1 DESIGN 224500-1 FIRING RANGE PHASE 1 DESIGN 224500-1 SECTION 224500 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS I. APPLICATION AND DEFINITIONS 1.01 Authorization for Standards 1.02 Application of Standards 1.03 Definitions

More information

PROTECTO 401 Price List

PROTECTO 401 Price List Price List January 1, 2015 Protecto 401 Price List Certification and General Installation Certification All Ductile Iron Spooling manufactured by is made in accordance with current ANSI/AWWA- C115/A21.15

More information

UNIVERSITY OF CHICAGO ELEVATOR PIT LEAK REPAIR

UNIVERSITY OF CHICAGO ELEVATOR PIT LEAK REPAIR ITEM: UNIVERSITY OF CHICAGO ELEVATOR PIT LEAK REPAIR DESCRIPTION: General Furnish all labor, equipment, and materials necessary and incidental thereto to perform all required operations to eliminate the

More information

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS January 1997 PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS 1.0 PERMIT 1.1 After receipt of a Building Permit from the City of San Jose Building Department, submit

More information

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities. SECTION 224500 - EMERGENCY PLUMBING FIXTURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS

SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS PART 1: GENERAL 1.01 COORDINATION OF WORK Connection to existing pipelines may require shutdown of AW facilities. Closely coordinate construction work

More information

ATTACHMENT 2: SPECIFICATION FOR SEWER CCTV VIDEO INSPECTION

ATTACHMENT 2: SPECIFICATION FOR SEWER CCTV VIDEO INSPECTION ATTACHMENT 2: SPECIFICATION FOR SEWER CCTV VIDEO INSPECTION 1.0 General 1.1 The work covered by this section consists of providing all labor, equipment, insurance, accessories, tools, transportation, supplies,

More information

Summary Of The Reduction Of Lead In Drinking Water Act And Frequently Asked Questions

Summary Of The Reduction Of Lead In Drinking Water Act And Frequently Asked Questions The Reduction of Lead in Drinking Water Act was enacted on January 4, 2011 to amend Section 1417 of the Safe Drinking Water Act (SDWA or Act) respecting the use and introduction into commerce of lead pipes,

More information

RAMAPO COLLEGE OF NEW JERSEY PHASE I HOUSING REHABILITATION C 2012

RAMAPO COLLEGE OF NEW JERSEY PHASE I HOUSING REHABILITATION C 2012 SECTION 04235 - BRICK PANEL SYSTEMS PART 1 - PRODUCT & DESCRIPTION Structural Support Panel System for Thin Brick shale be Tabs II, manufactured by Tabs Wall System, LLC, Grandville, MI 49468, (616) 261-5656.or

More information

FIRE SAFETY MANUAL INSPECTION FORMS...48 FORM F-1 AUTOMATIC SPRINKLER SYSTEMS WEEKLY INSPECTION...48 FORM F-2 AUTOMATIC SPRINKLER SYSTEMS MONTHLY

FIRE SAFETY MANUAL INSPECTION FORMS...48 FORM F-1 AUTOMATIC SPRINKLER SYSTEMS WEEKLY INSPECTION...48 FORM F-2 AUTOMATIC SPRINKLER SYSTEMS MONTHLY FIRE SAFETY MANUAL INSPECTION FORMS...48 FORM F-1 AUTOMATIC SPRINKLER SYSTEMS WEEKLY INSPECTION...48 FORM F-2 AUTOMATIC SPRINKLER SYSTEMS MONTHLY INSPECTION...49 FORM F-3 AUTOMATIC SPRINKLER SYSTEMS QUARTERLY

More information

Procedures for New Watermains 5/7/2007

Procedures for New Watermains 5/7/2007 INTRODUCTION These procedures cover the cleaning, disinfection, hydrostatic testing and sampling of watermains. Unless specified otherwise this procedure applies to all new watermains and includes above

More information

1.02 Scope of Work A. Provide a complete fire pump system as defined by the latest edition of NFPA 20

1.02 Scope of Work A. Provide a complete fire pump system as defined by the latest edition of NFPA 20 PART 1 GENERAL 1.01 Scope of Standard A. This standard provides general requirements of The Sam Houston State University for fire pumps. This document is not intended to serve as a guide specification.

More information

SECTION 33 12 19 FIRE HYDRANTS

SECTION 33 12 19 FIRE HYDRANTS SECTION 33 12 19 FIRE HYDRANTS PART 1: GENERAL 1.01 SCOPE A. Fire hydrants. B. Adjustment of fire hydrants and gate valves. 1.02 SUBMITTALS A. Conform to requirements of Section 01 33 00 - Submittals.

More information

A comprehensive range

A comprehensive range The professionals in coated pipelines A comprehensive range We have reduced our machine set-up times to offer a fast turnaround for fusion bonded epoxy, multi-layer and internal pipe coatings. All coating

More information

MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water

MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water 105 Decker Court, Suite 825, Irving, TX 75062 P: 469-499-1044 F: 469-499-1063 www.plasticpipe.org HDPE

More information

BELCO PIPE RESTORATION

BELCO PIPE RESTORATION superior PIPE RESTORATION SOLUTIONS BELCO PIPE RESTORATION Proven, state-of-the-art technology that saves money, time and inconvenience. Replacing pipes is expensive and time consuming. It disrupts businesses,

More information

Essentials Welding QA/QC Plan Sample

Essentials Welding QA/QC Plan Sample Essentials Welding QA/QC Plan Sample Good for smaller projects and bid qualifications Has All the Essential Elements of a well-founded Quality Control Plan Contact: Ed Caldeira 410-451-8006 Pat [Pick the

More information

APPENDIX B. Magna Reservoir Leak Detection & Water Quality Sampling Plan (Revised June 2011)

APPENDIX B. Magna Reservoir Leak Detection & Water Quality Sampling Plan (Revised June 2011) APPENDIX B Magna Reservoir Leak Detection & Water Quality Sampling Plan (Revised June 2011) 1.0 Introduction The Magna Reservoir System, located in the North Concentrator facilities area, acts as a central

More information

SECTION 33 05 16.13 PRECAST CONCRETE UTILITY STRUCTURES

SECTION 33 05 16.13 PRECAST CONCRETE UTILITY STRUCTURES SECTION 33 05 16.13 PRECAST CONCRETE PART 1 - GENERAL 1.01 SECTION INCLUDES A. This item shall consist of the construction of both sanitary and storm sewer precast concrete manholes in accordance with

More information

Public Health Considerations for Installation/Repair of Mains

Public Health Considerations for Installation/Repair of Mains Public Health Considerations for Installation/Repair of Mains Public Health Considerations for Installation/Repair of Mains Public Health Considerations Hydrostatic Testing Disinfection and Bacteriological

More information

FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011

FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011 Office of the Fire Marshal 1.0 PERMITS FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011 1.1 To acquire an installation

More information

COMMISSIONING OF FIRE PROTECTION SYSTEMS

COMMISSIONING OF FIRE PROTECTION SYSTEMS COMMISSIONING OF FIRE PROTECTION SYSTEMS OWNER FURNISHED The owner directly contracts an independent third party commissioning agent for this project. This Commissioning Plan has been included for reference

More information

WEKO-SEAL Internal Joint Sealing WEKO-SEAL. internal pipe-joint sealing

WEKO-SEAL Internal Joint Sealing WEKO-SEAL. internal pipe-joint sealing WEKO-SEAL Internal Joint Sealing WEKO-SEAL internal pipe-joint sealing We know seals inside and out. Retaining Band Test Valve WEKO-SEAL WEKO-SEAL is the leading trenchless system for internally and economically

More information

A World Class Manufacturer of Induction Bends

A World Class Manufacturer of Induction Bends A World Class Manufacturer of Induction Bends COFELY FABRICOM BENDING A leading position in bending High Flexibility and Close Tolerances As a world leading manufacturer of pipe bends, produced by induction

More information

Guide on the Segregation, Packaging, Labelling and Storage of Laboratory Chemical Wastes for Schools

Guide on the Segregation, Packaging, Labelling and Storage of Laboratory Chemical Wastes for Schools APPENDIX II Guide on the Segregation, Packaging, Labelling and Storage of Laboratory Chemical Wastes for Schools (Prepared by Environmental Protection Department) 1. Introduction The Waste Disposal (Chemical

More information

New Door and Window Openings - Building Permit Application Requirements

New Door and Window Openings - Building Permit Application Requirements New Door and Window Openings - Building Permit Application Requirements A building permit is required when installing a new door or window opening in an exterior wall (e.g. new side door) or when increasing

More information

The following definitions apply with regard to requirements specified in this document:

The following definitions apply with regard to requirements specified in this document: GUIDELINES FOR INSTALLATION OF TEMPORARY AND PERMANENT ABOVEGROUND DIESEL FUEL TANKS FOR EMERGENCY AND STANDBY POWER SYSTEMS LOCATED OUTSIDE OF BUILDINGS For Use by Unidocs Member Agencies or where approved

More information

UNIVERSITY OF TOLEDO

UNIVERSITY OF TOLEDO UNIVERSITY OF TOLEDO SUBJECT: INTERIM LIFE SAFETY MEASURES AND INFECTION Procedure No: LS-08-008 CONTROL PROCEDURE STATEMENT Interim life safety and infection control measures will be implemented to protect

More information

City facilities that are currently part of the System are listed below. Other City facilities may be added in the future.

City facilities that are currently part of the System are listed below. Other City facilities may be added in the future. Equipment and Building Services Department, Security Division Introduction The City of Dallas (City) Equipment and Building Service (EBS) Security Division is requesting Bids to provide Security System

More information

Georgia State Amendments to the International Mechanical Code (2012 Edition)

Georgia State Amendments to the International Mechanical Code (2012 Edition) Georgia State Amendments to the International Mechanical Code (2012 Edition) Georgia Department of Community Affairs Community Development Division 60 Executive Park South, N.E. Atlanta, Georgia 30329-2231

More information

Element D Services Plumbing

Element D Services Plumbing Laboratory Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses laboratory vacuum, compressed air, gaseous nitrogen, and carbon dioxide systems within and to five feet beyond building

More information

CHAPTER 69A-46 FIRE PROTECTION SYSTEM CONTRACTORS AND SYSTEMS

CHAPTER 69A-46 FIRE PROTECTION SYSTEM CONTRACTORS AND SYSTEMS CHAPTER 69A-46 FIRE PROTECTION SYSTEM CONTRACTORS AND SYSTEMS 69A-46.001 69A-46.010 69A-46.015 69A-46.016 69A-46.0165 69A-46.017 69A-46.025 69A-46.030 69A-46.035 69A-46.040 69A-46.041 Scope Submission

More information

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Rancho Cucamonga Fire Protection District Prevention Bureau Standard Rancho Cucamonga Fire Protection District Prevention Bureau Standard Title: Fire Alarm and Monitoring Systems Standard # 9-3 Effective: May 2002 Number of Pages: 7 Revised: January 2014 INTENT The intent

More information

SECTION 02110 - ASBESTOS CEMENT PIPE REPAIRS, DEMOLITION, AND DISPOSAL

SECTION 02110 - ASBESTOS CEMENT PIPE REPAIRS, DEMOLITION, AND DISPOSAL SECTION 02110 - ASBESTOS CEMENT PIPE REPAIRS, DEMOLITION, AND DISPOSAL PART 1 - GENERAL 1.1 WORK INCLUDED IN THIS SECTION A. The WORK of this Section includes the repair, demolition, and disposal of asbestos

More information

Request for Proposals Sanitary Sewer System Condition Assessment (PILOT PROJECT)

Request for Proposals Sanitary Sewer System Condition Assessment (PILOT PROJECT) Request for Proposals Sanitary Sewer System Condition Assessment (PILOT PROJECT) Utilizing CCTV equipment, equipment use training, NASSCO PACP defect coding, and infrastructure program management software

More information

Section A SPCC Plan Implementation Checklist This section of the report addresses compliance with certain requirements of Federal Regulations 40 CFR 112. I. STATUS OF SPCC PLAN (40 CFR 112.3) YES NO A.

More information

F.Y.I. Specifying Fire Protection Systems Using Division 13

F.Y.I. Specifying Fire Protection Systems Using Division 13 F.Y.I. Specifying Fire Protection Systems Using Division 13 Automatic fire sprinkler systems and fire alarm and detection systems are increasingly installed in modern buildings. Even where building codes

More information

2014 Limited Plan Submittal Checklist

2014 Limited Plan Submittal Checklist City of Aurora Public Works Department WET AND DRY CHEMICAL HOOD SUPPRESSION SYSTEM 2014 Limited Plan Submittal Checklist Building Division 15151 E. Alameda Parkway, Ste 2400 Aurora, CO 80012 303-739-7420

More information

FVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY

FVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY FVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fire-alarm control unit. 2. Addressable interface

More information

Select Radiators Installation Guide

Select Radiators Installation Guide Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall

More information

Defense Technical Information Center Compilation Part Notice

Defense Technical Information Center Compilation Part Notice UNCLASSIFIED Defense Technical Information Center Compilation Part Notice ADP017725 TITLE: Restoration of drinking Water Piping with Nontoxic Epoxy Linings DISTRIBUTION: Approved for public release, distribution

More information

LIST PRICE BOOK MALLEABLE CAST IRON PRESS FITTINGS FOR SCH. 10 40 BLACK & GALVANIZED STEEL PIPE

LIST PRICE BOOK MALLEABLE CAST IRON PRESS FITTINGS FOR SCH. 10 40 BLACK & GALVANIZED STEEL PIPE FASTLOCK fittings are not currently approved for use with gas or fire protection applications. FITTINGS FOR STEEL PIPE LIST PRICE BOOK MALLEABLE CAST IRON FITTINGS FOR SCH. 10 40 BLACK & GALVANIZED STEEL

More information

Fuels Safety Program. Liquid Fuels Handling Code Adoption Document Amendment

Fuels Safety Program. Liquid Fuels Handling Code Adoption Document Amendment Fuels Safety Program Liquid Fuels Handling Code Adoption Document Amendment Ref. No.: FS-207-14 Date: IN THE MATTER OF: Technical Standards and Safety Act 2000, S.O. 2000, c. 16, and Ontario Regulation