How To Get A Better Pay Out Of A Car

Size: px
Start display at page:

Download "How To Get A Better Pay Out Of A Car"

Transcription

1 VA / V / V WET ROTOR CIRCUATORS VA V V TECNICA ATA Operating range: from. to 3, m3/h with head up to metres. Pumped liquid temperature range: from -1 C to +11 C. Pumped liquid: clean, free from solids and mineral oils, non viscous, chemically neutral, close to the characteristics of water (max 3% glycol). Maximum operating pressure: 1 bar (1 kpa). Minimum suction pressure: the values are given in the relative tables. Installation: with ORIZONTA MOTOR SAT on discharge or return pipe, with suction port as close as possible to expansion vessel, above maximum boiler level and as far as possible from bends, elbows, and circuit branches to avoid water turbulence with consequent noise. Protection level: corresponding to IP Insulation class: Cable groet: PG 11 Special executions on requests: alternative voltages and/or frequencies. Optional accessories: r 3 / / / M unions N-N-N3 oval counter-flanges N3/PN round counter-flanges APPICATIONS Pump for hot water circulation in domestic central heating and air conditioning systems of the closed circuit pressurized type or open circuit type. CONSTRUCTION EATURES Enbloc body composed of hydraulic section in cast iron and wet rotor motor. Motor casing in die cast aluminium. Impeller in technopolymer. Motor shaft in hardened stainless steel held in graphite bearings lubricated by the pumping medium. Rotor protective jacket, stator jacket, and closing flange in stainless steel. Ceramic thrust ring, ethylene-propylene seal rings and brass air breather plug. The two-pole asynchronous wet-rotor motor is resistance protected and does not require any form of overload protection. Three-speed operation. Protection rating: IP Insulation class: Cable gland: PG 11 Installation: with horizontal motor shaft. Standard voltage input: single-phase 3 V / z Special versions on request - alternative voltages and/or frequencies WET ROTOR CIRCUATORS A PUMPS reserves the right to make modifications without notice. 1

2 VA / V / V WET ROTOR CIRCUATORS MATERIAS N. PARTS MATERIAS PUMP OY CAST IRON IMPEER TECNOPOYMER 7A MOTOR SAT STAINESS STEE 7 ROTOR 13 7A STATOR 9 CAPACITOR 1 VA 1 MOTOR CASING IE CAST AUMINIUM 11 REATER PUG RASS WET ROTOR CIRCUATORS 1 TERMINA OX 17 SEA RING ETYENE POYPROPYENE 1 STATOR JACKET STAINESS STEE 19 ROTOR JACKET STAINESS STEE 13 COSING ANGE STAINESS STEE 131 TRUST RING SUPPORT ETYENE PROPYENE 13 7A USINGS GRAPITE 133 TRUST RING CERAMIC V egend: (example) VA / 1 X VA V V = single circulator = circulator with N oval flanges = twin circulator maximum head (dm) centre distance () standard (no ref.) 1 / X 3 = 1 1 / threaded ports = 1 threaded ports = threaded ports = N3/PN/1 flanged ports A PUMPS reserves the right to make modifications without notice. 1

3 VA / V / V WET ROTOR CIRCUATORS PERORMANCE RANGE 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. GRAPIC SEECTION TAE P kpa m, , Q US gpm Q IMP gpm ft A - - M P 3 WET ROTOR CIRCUATORS 3 3 M P 1 VA - V - V VS 1 1,1,,3,,, Q /h,1, Q l/s Q l/min A PUMPS reserves the right to make modifications without notice. 17

4 VA / V / V WET ROTOR CIRCUATORS SEECTION TAE - VA SINGE WIT UNIONS VA /13 Q= /h, 1, 1,, 3, Q=l/min 1 3 7,71,,1 1,7 1,, VA /1,71,,1 1,7 1,, VA /1X,71,,1 1,7 1,, VA 3/13,3 3,9 3,,,1 1, VA 3/13-1 /,3 3,9 3,,,1 1, VA 3/1,3 3,9 3,,,1 1, VA 3/1 X,3 3,9 3,,,1 1, VA /13 (m),,7, 3,3, 1,7, WET ROTOR CIRCUATORS VA /13-1 /,,7, 3,3, 1,7, VA /1,,7, 3,3, 1,7, VA /1 X,,7, 3,3, 1,7, VA /13,3,,3,3 3,, VA /13-1 /,3,,3,3 3,, VA /1,3,,3,3 3,, VA /1 X,3,,3,3 3,, SEECTION TAE - V SINGE WIT OVA ANGES V 3/1 Q= /h, 1, 1,, 3, Q=l/min 1 3 7,3 3,9 3,,,1 1, V /1 (m),,7 3,3, 1,7, V /1,3,,3,3 3,, SEECTION TAE - V TWIN WIT ANGES Q= /h, 1, 1,, 3, Q=l/min V /.3,,7, 3,3, 1,7, V /.3 (m),3,,3,3 3,, A PUMPS reserves the right to make modifications without notice. 1

5 VA /13 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h.... Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z VA / x3 V ~ 1 ¾ - 1¼ M UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A µ Vc t 9 3 3,19 3 3,17 1, m.c.a. 1, ,1 1 VA / , 7, 1, 7, ,7, VOUME WEIGT WET ROTOR CIRCUATORS VA /1 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h.... Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z VA /1 1 1x3 V ~ 1 ¾ - 1¼ M UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A µ Vc t 9 3 3,19 3 3,17 1, m.c.a. 1, ,1 1 VOUME WEIGT VA / , 7, 1, 7, ,37, A PUMPS reserves the right to make modifications without notice. 19

6 VA /1X - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h.... Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. WET ROTOR CIRCUATORS z VA /1X 1 1x3 V ~ 1 ¼ UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPEE 1/min W A µ Vc t 9 3 3,19 3 3,17 1, m.c.a. 1, ,1 1 VA /1X , 7, 1, 7, ,37, VOUME WEIGT VA 3/13 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h.... Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z VA 3/ x3 V ~ 1 ¾ - 1¼ M UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A µ Vc t 9 3, 193, 1,7 m.c.a. 1, ,1 1 VOUME WEIGT VA 3/ , 7, 1, 7, ,7, A PUMPS reserves the right to make modifications without notice. 11

7 VA 3/13-1 / - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h.... Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z VA 3/13-1 / 13 1x3 V ~ UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A µ Vc t 9 3, 193, 1,7 m.c.a. 1, ,1 1 VA 3/13-1 / , 7, 1, 7, ,7, VOUME WEIGT WET ROTOR CIRCUATORS VA 3/1 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h.... Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z VA 3/1 1 1x3 V ~ 1 ¾ - 1¼ M UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A µ Vc t 9 3, 193, 1,7 m.c.a. 1, ,1 1 VOUME WEIGT VA 3/ , 7, 1, 7, ,37, A PUMPS reserves the right to make modifications without notice. 111

8 VA 3/1X - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h.... Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. WET ROTOR CIRCUATORS z VA 3/1X 1 1x3 V ~ UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A µ Vc t 9 3, 193, 1,7 m.c.a. 1, ,1 1 VA 3/1X , 7, 1, 7, ,37, VOUME WEIGT VA /13 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z VA / x3 V ~ 1 ¾ - 1¼ M UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A µ Vc t 9 3 7,3 1, 1,7 m.c.a. 1, ,17 1 VOUME WEIGT VA / , 7, 1, 7, ,7, A PUMPS reserves the right to make modifications without notice. 11

9 VA /13-1 / - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z VA /13-1 / 13 1x3 V ~ UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A µ Vc t 9 3 7,3 1, 1,7 m.c.a. 1, ,17 1 VA /13-1 / , 7, 1, 7, ,7, VOUME WEIGT WET ROTOR CIRCUATORS VA /1 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z VA /1 1 1x3 V ~ 1 ¾ - 1¼ M UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A µ Vc t 9 3 7,3 1, 1,7 m.c.a. 1, ,17 1 VOUME WEIGT VA / , 7, 1, 7, ,37, A PUMPS reserves the right to make modifications without notice. 113

10 VA /1X - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. WET ROTOR CIRCUATORS z VA /1X 1 1x3 V ~ 1 ¼ UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPEE 1/min W A µ Vc t 9 3 7,3 1, 1,7 m.c.a. 1, ,17 1 VA /1X , 7, 1, 7, ,37, VOUME WEIGT VA /13 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z VA / x3 V ~ 1 ¾ - 1¼ M UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A µ Vc t ,3 13 9, m.c.a., 1 37,17 1 VOUME WEIGT VA / , 7, 1, 7, ,7, A PUMPS reserves the right to make modifications without notice. 11

11 VA /13-1 / - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z VA /13-1 / 13 1x3 V ~ UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A µ Vc t ,3 13 9, m.c.a., 1 37,17 1 VA /13-1 / , 7, 1, 7, ,7, VOUME WEIGT WET ROTOR CIRCUATORS VA /1 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z VA /1 1 1x3 V ~ 1 ¾ - 1¼ M UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A µ Vc t ,3 13 9, m.c.a., 1 37,17 1 VOUME WEIGT VA / , 7, 1, 7, ,37, A PUMPS reserves the right to make modifications without notice. 11

12 I I VA /1X - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. WET ROTOR CIRCUATORS z VA /1X 1 1x3 V ~ 1 ¼ UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPEE 1/min W A µ Vc t ,3 13 9, m.c.a., 1 37,17 1 VA /1X , 7, 1, 7, ,37, VOUME WEIGT V 3/1 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm 1 1 Q IMP gpm m t Q /h.... Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z V 3/1 1 1x3 V ~ N UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A t 9 µ Vc 3, N 193, 1,7 m.c.a. 1, N ,1 1 1 I VOUME WEIGT V 3/ M ,7,7 A PUMPS reserves the right to make modifications without notice. 11

13 I I I I V /1 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z V /1 1 1x3 V ~ N UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A t 9 µ Vc 3 7,3 N 1, 1,7 m.c.a. 1, N , I V / M ,7,7 VOUME WEIGT WET ROTOR CIRCUATORS V /1 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z V /1 1 1x3 V ~ N UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A t 9 µ Vc ,3 N 13 9, m.c.a., N ,17 1 I 1 VOUME WEIGT V / M ,7,7 A PUMPS reserves the right to make modifications without notice. 117

14 V /.3 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. WET ROTOR CIRCUATORS z UNIONS ON REQUEST V /.3 1x3 V ~ N 3 / PN / PN 1 SPEE 3 1 REV. 1/min 1 93 EECTRICA ATA P1 MAX W In A 7,3, 3,17 CAPACITOR µ Vc MINIMUM SUCTION PRESSURE t 9 1,7 m.c.a. 1, 1 1 PN PN1 PN PN1 V / , 1, ,9, VOUME WEIGT V /.3 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z UNIONS ON REQUEST V /.3 1x3 V ~ N 3 / PN / PN 1 SPEE 3 1 REV. 1/min EECTRICA ATA P1 MAX W In A 7,3 9, 37,17 MINIMUM SUCTION PRESSURE CAPACITOR t 9 µ Vc m.c.a., 1 1 PN PN1 PN PN1 VOUME WEIGT V /.3 91, 1, ,9, A PUMPS reserves the right to make modifications without notice. 11

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS 2CP Twin-impeller pumps PERFORMANCE RANGE Flow rate up to 40 l/min (27 m³/h) Head up to 112 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C Ambient temperature

More information

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100 CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 90 203 PERFORMANCE CHART 120 204 PERFORMANCE CHART 200 205 - CONSTRUCTIONS 300 SECTIONAL

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS

More information

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to: OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND

More information

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design, The Company QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design, manufacturing and service needs in the field of submersible pumps. Our engineering

More information

RPT SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS 426 2.98 23.01

RPT SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS 426 2.98 23.01 SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS RPT SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +4 581 661 111, fax: +4 581 602 587 Email: sigmahra@sigmahra.cz 426

More information

1.0 2.0 3.0 4.0 5.0 6.0 7.0. Q [m 3 /h] Wilo-Star Cast iron body 60 Hz. Star 30 F. Star 21. Star 17 FX. 4 8 12 16 20 24 28 Q [US gpm]

1.0 2.0 3.0 4.0 5.0 6.0 7.0. Q [m 3 /h] Wilo-Star Cast iron body 60 Hz. Star 30 F. Star 21. Star 17 FX. 4 8 12 16 20 24 28 Q [US gpm] Product review: Range: Wilo-Star....... Star F Star Star Star F Star Star FX [m /h] Wilo-Star Cast iron body Hz [US gpm].......... [m /h] Wilo-Star Bronze body 9 Hz [US gpm] Star Star Star Star Star BF

More information

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html

More information

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html

More information

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

Laing industrial pumps

Laing industrial pumps Laing industrial pumps... with spherical motor, robust and reliable! Normal suction centrifugal pumps! Self-priming pumps! Ecocirc DC pumps Summary Chapter Page Normal suction centrifugal pumps... 3 Application...

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

SJT / SJM / SJP Large Vertical Pumps

SJT / SJM / SJP Large Vertical Pumps SJT / SJM / SJP Large Vertical Pumps The Heart of Your Process SJT, SJM, SJP Large Vertical Pumps Product Overview SJT Turbine Ns 1800 < 5000 nq 35 < 110 SJM Mixed Flow Ns 5800 < 8300 nq 113 < 161 SJP

More information

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS 426 2.98 12.06

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS 426 2.98 12.06 SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS LV SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +420 581 661 111, fax: +420 581 602 587 Email: sigmahra@sigmahra.cz

More information

Series description: Wilo-Star-Z

Series description: Wilo-Star-Z H[m] Series description: Wilo-Star-Z 4 3 Wilo-Star-Z Star-Z 2/5 2/4 2 1 Star St ar- Z1 5T Design Glandless circulation pump with threaded connection Application Potable water circulation systems in industry

More information

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Ergo-Pro Single Line Solar Station Installation and Operating Instructions Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating

More information

Horizontal Jet Pumps 1/3-1-1/2 HP

Horizontal Jet Pumps 1/3-1-1/2 HP Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The

More information

Series description: Wilo-Yonos MAXO

Series description: Wilo-Yonos MAXO 16 88 / Series description: Wilo-Yonos MAXO /,5-1 1 Wilo-Yonos MAXO 1 5/,5-1 8 6 /,5-5/3/,5-7 5/3/,5-1 /5/,5-8 65/,5-9 5/,5-9 5/3/,5-1 5 1 15 5 Design Glandless circulation pump with threaded connection

More information

MEMBRANE VACUUM MINI PUMPS

MEMBRANE VACUUM MINI PUMPS MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free

More information

Max. Head (m) LVR3-7-220V 3 32 5 44 0,55 10 50Hz ~ 220 V Oval Flange G1. LVR3-7-380V 3 32 5 44 0,55 10 50Hz ~ 380 V Oval Flange G1

Max. Head (m) LVR3-7-220V 3 32 5 44 0,55 10 50Hz ~ 220 V Oval Flange G1. LVR3-7-380V 3 32 5 44 0,55 10 50Hz ~ 380 V Oval Flange G1 Description NordicFlow s keep the system pressurized during normal conditions and prevent unnecessary activation of the main pump. They have compact design, high efficiency, low noise, reliable sealing

More information

The conditions below apply to the curves shown on the following pages.

The conditions below apply to the curves shown on the following pages. GENERAL INFORMATION STAINLESS STEEL, SILVERLINE, EVERGREEN & GOLDLINE SERIES PERFORMANCE CURVE CONDITIONS The conditions below apply to the curves shown on the following pages. a. The Performance curves

More information

PUMP AND MOTOR DIVISION

PUMP AND MOTOR DIVISION INSTALLATION MANUAL SERIES P2 and P3 MOBILE PISTON PUMP 1 Check model code / compare with your paper work Nameplate of the pump Ordering / Sales Acknowledgement 2 Check rotation of the pump Clockwise rotation

More information

Series description: Wilo-Yonos MAXO-D

Series description: Wilo-Yonos MAXO-D ATAC Solutions LTD / 1 / Series description: 1 /,5-1 1 5/,5-1 3/,5-7 3 3 5/ /, / 11 5-,5-,5-9 Design Glandless circulation pump with threaded connection or flange connection, EC motor with automatic power

More information

Vertical Multistage Centrifugal Electric Pumps SV2-4-8-16 Series NEW LASER TECHNOLOGY

Vertical Multistage Centrifugal Electric Pumps SV2-4-8-16 Series NEW LASER TECHNOLOGY Vertical Multistage Centrifugal Electric Pumps SV2-4-8-16 Series NEW LASER TECHNOLOGY TYPICAL APPLICATIONS Water supply Transfer and distribution from water systems Pressure boosting in apartment buildings

More information

Series description: Wilo-Drain TC 40

Series description: Wilo-Drain TC 40 Series description: Wilo-Drain TC 40 H[m] Wilo-Drain TC 40 10 8 6 4 2 TC 40/8 TC 40/10 0 0 2 4 6 8 10 12 14 Q[m³/h] Design Submersible sewage pump Application Pumping heavily contaminated fluids for House/site

More information

Rules for Classification and Construction Additional Rules and Guidelines

Rules for Classification and Construction Additional Rules and Guidelines VI Rules for Classification and Construction Additional Rules and Guidelines 5 Pumps 1 Guidelines for the Design, Construction and Testing of Pumps Edition 2007 The following Guidelines come into force

More information

SVA SIGMA PUMPY HRANICE SELF PRIMING PUMPS 426 2.98 16.05

SVA SIGMA PUMPY HRANICE SELF PRIMING PUMPS 426 2.98 16.05 SIGMA PUMPY HRANICE SELF PRIMING PUMPS SVA SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +40 581 661 111, fax: +40 581 60 587 Email: sigmahra@sigmahra.cz 46.98 16.05 Applications

More information

Dry Pit Solids Handling Pumps

Dry Pit Solids Handling Pumps Dry Pit Solids Handling Pumps A Time-Tested Leader Chicago Pump Dry Pit Solids Handling Pumps have an established reputation of efficiency, long life and reliable operation First in: Quality 3Reliability

More information

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages 2448LSG_P1 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

Flygt N-Pumps 3085, 3102 & 3127. For reliable and efficient wastewater handling

Flygt N-Pumps 3085, 3102 & 3127. For reliable and efficient wastewater handling Flygt N-Pumps 3085, 3102 & 3127 For reliable and efficient wastewater handling The Concept Flygt N-Pump series Reduced pumping efficiency, high energy and maintenance costs shouldn t be a fact of life

More information

Ecocirc, EB, EBV, TLCB, TLCHB Series

Ecocirc, EB, EBV, TLCB, TLCHB Series Hz Ecocirc, EB, EBV, TLCB, TLCHB Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS ErP 9//EC Cod. 97 Rev ev.a.a Ed./ Lowara is a trademark of Lowara srl Unipersonale, subsidiary of

More information

Turbine Flow Sensor Series VTR

Turbine Flow Sensor Series VTR Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates

More information

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

MARKET SECTORS CIVIL, AGRICULTURAL, INDUSTRIAL.

MARKET SECTORS CIVIL, AGRICULTURAL, INDUSTRIAL. Twin- Impeller Centrifugal Electric Pumps CA-CA(N) Series Standard supplied IE2 motors are compliant with Regulation (EC) no. 640/2009. MARKET SECTORS CIVIL, AGRICULTURAL, INDUSTRIAL. APPLICATIONS Version

More information

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR INLINE SD-PUMPS WITH IEC-STANDARD MOTOR AT_-1/ Hz DN1 3 r/min min H G 1/ G 1/ 17 11 3xM, Depth 1 1 Ø1 Ø1 xø19 7 3xØ1 9 17 1 xø1 17 1 kw A kg H OKN-13 E1 F19 7. (9). 9 OKN-13 C1 F19. (.) 11. 1 9 OKN-1 E1

More information

SIGMA GROUP a. s. Divize průmyslová čerpadla

SIGMA GROUP a. s. Divize průmyslová čerpadla SIGMA GROUP a. s. Divize průmyslová čerpadla SIGMA GROUP a. s. INDUSTRIAL PUMP DIVISION Jana Sigmunda 79, 783 50 LUTÍN SEWAGE PUMPS NFPH, NFVH, NFJH, NFRH, NFPV, NFVV, NFJV, NFRV, NFPW NFVW Tel.: +420

More information

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications. The

More information

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from

More information

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com Model 62A MODEL 41A MODEL 44A AURORA 40A/60A Series SINGLE STAGE END PUMPS www.aurorapump.com SINGLE STAGE END PUMPS AURORA 40A/60A Series Single Stage End Suction Pumps Capacities to 4500 G.P.M. (1022

More information

Operating instructions Mechatronic flow sensor. SBY33x 704465/06 03/2011

Operating instructions Mechatronic flow sensor. SBY33x 704465/06 03/2011 Operating instructions Mechatronic flow sensor SBY33x 7065/06 03/2011 Contents 1 Safety instructions...2 2 Functions and features...3 3 Installation...3 Electrical connection... 5 Switch point setting...

More information

ZOP, ZOT SIGMA PUMPY HRANICE GEAR PUMPS 426 1.99 21.04

ZOP, ZOT SIGMA PUMPY HRANICE GEAR PUMPS 426 1.99 21.04 SIGMA UMY HRANICE GEAR UMS SIGMA UMY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +420 581 661 111, fax: +420 581 602 587 Email: sigmahra@sigmahra.cz, 426 1.99 21.04 Application In

More information

Product Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz

Product Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz Product Catalogue ETX, Stainless steel threaded centrifugal pumps, Hz Contents Introduction... ETX... Choosing the right pump There are a wide range of pumps to select from. In order to find the right

More information

Conlift1, Conlift2, Conlift2 ph+

Conlift1, Conlift2, Conlift2 ph+ GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications

More information

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products. Our Other Products OUR PRODUCTS Liquid Ring & Rotary Vane Vacuum Pumps and Systems Liquid Ring Vacuum Pumps: 3 CFM to,000 CFM Liquid Ring Compressors up to 1 psig Heat Transfer Pumps for hot thermal oils

More information

08.08 Vic-Check Valves

08.08 Vic-Check Valves The check valves are a product of computer-assisted innovative engineering with quality features including a new hydrodynamically efficient profile. The Vic-Check valve utilizes a spring-assisted, single-disc

More information

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:

More information

Butterfly Valves PN 6/10/16 for flanged connection

Butterfly Valves PN 6/10/16 for flanged connection 4 136 ACVATIX Butterfly Valves PN 6/10/16 for flanged connection tight-closing VKF46.. VKF46..TS Grey cast iron housing EN-GJL-250 (to DN 300) nodular cast iron housing EN-GJS-400-15 (from DN 350) DN 40

More information

KTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

KTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet KTZ32.2-5 data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str.6 40472 Düsseldorf Germany Tel.: +49-2-479373 Fax: +49-2-479429

More information

Multistage high-pressure multistage centrifugal pumps

Multistage high-pressure multistage centrifugal pumps Series description Wilo-Helix V 2 4 6 8 Wilo-Helix V 19-27 7 6 6 Hz - North America 22 2 18 5 16 14 4 12 3 1 V 1 V 19 V 27 8 2 6 1 5 1 15 2 25 3 4 2 35Q[US gpm] H[ft] H[m] Design Vertical multi-stage,

More information

Flygt 3068, 50Hz. Technical Specification

Flygt 3068, 50Hz. Technical Specification Flygt 3068, 50Hz Technical Specification Table of Contents Table of Contents B-pump...2 Product description...2 Motor rating and performance curves...4 C-pump...6 Product description...6 Motor rating

More information

50/60 Hz. ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS. ErP 2009/125/EC. Cod.

50/60 Hz. ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS. ErP 2009/125/EC. Cod. / Hz ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS ErP 9//EC Cod. 9 Rev ev.a.a Ed./ ecocirc BASIC SERIES INSTALLA ALLATION POSITIONS Lowara, ecocirc, Xylect are trademarks

More information

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS. Redi-Flo2, 2 Environmental Submersible Pumps MP1 Submittal Data QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS Technical Data Motor Type: Water-Filled, variable speed submersible Maximum Fluid

More information

Model 1210C Battery Powered Pump Shown. Description

Model 1210C Battery Powered Pump Shown. Description 12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with

More information

SUPER-TITAN. Split-case pumps with power, performance and reliability for a world of applications

SUPER-TITAN. Split-case pumps with power, performance and reliability for a world of applications SUPER-TITAN Split-case pumps with power, performance and reliability for a world of applications The Prestige. The Performance. SUPER-TITAN PUMPS Features The TKL Super-Titan pump makes a significant contribution

More information

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO) SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY

More information

Catalogue Wilo- Stratos PARA

Catalogue Wilo- Stratos PARA Heating, ir Condition, Cooling, Geothermal heat, Solar heat 25-50W 100W 200W Catalogue Wilo- Stratos PR Wilo-Stratos PR 15/1-5; 20/1-5; 25/1-5; 30/1-5 Wilo-Stratos PR 15/1-7; 20/1-7; 25/1-7; 30/1-7 Wilo-Stratos

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA/UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance

More information

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version instrumentation for fluids Electromagnetic sensor Series FLOMID FX Instructions Manual! Conforms with the Pressure Equipment Directive 97/23/EC. 0830 This equipment is considered as being a pressure accessory

More information

Vertical selfpriming Side-Channel Pumps Type WPV

Vertical selfpriming Side-Channel Pumps Type WPV Vertical selfpriming Side-Channel Pumps Type WPV FIELD OF APPLICATION The side-channel pumps are selfpriming and operate more economically (better efficiency) than normal centrifugal pumps when handling

More information

2- and 3-port valves with flanged connections, PN 10

2- and 3-port valves with flanged connections, PN 10 4 402 VVF32.. VXF32.. ACVATIX 2 and 3port valves with flanged connections, PN 10 From the largestroke valve line VVF32.. VXF32.. Performance valves for medium temperatures from 10 150 C Valve body of grey

More information

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of

More information

Globo P. Ball valves Pump ball valve made of gunmetal

Globo P. Ball valves Pump ball valve made of gunmetal Globo Ball valves ump ball valve made of gunmetal IMI EIMEIER / Shut-off valves / Globo Globo Globo and Globo -S are used in pump warm water heating systems for direct connection to circulating pumps with

More information

MULTISTAGE CENTRIFUGAL PUMPS

MULTISTAGE CENTRIFUGAL PUMPS MULTISTAGE CENTRIFUGAL PUMPS MULTISTAGE CENTRIFUGAL PUMPS TK - TKR - VTK - TKK series TK-VTK-TKR-TKK are high pressure multistage pumps. Connection to the driving machine (generally an electrical motor)

More information

Pumps SELECTION OF A PUMP

Pumps SELECTION OF A PUMP Pumps SELECTION OF A PUMP A water system needs to move the water produced from the source to its customers. In almost all cases in Minnesota, the source is at a lower elevation than the user so the water

More information

Slide 1. Slide 2. Slide 3 288,817,200,000. Thank you for attending the session on Hot Water Re-Circulation.

Slide 1. Slide 2. Slide 3 288,817,200,000. Thank you for attending the session on Hot Water Re-Circulation. Slide 1 Thank you for attending the session on Hot Water Re-Circulation. Hot Water Re-Circulation National Conference Center Lansdowne, VA March 25 th & 26 th, 2010 Slide 2 AGENDA Water Waste Statistics

More information

FAIRBANKS NIJHUIS FIRE PUMPS. www.fairbanksnijhuis.com

FAIRBANKS NIJHUIS FIRE PUMPS. www.fairbanksnijhuis.com FAIRBANKS NIJHUIS FIRE PUMPS www.fairbanksnijhuis.com FAIRBANKS NIJHUIS Long established as a leading fire pump manufacturer, Fairbanks Nijhuis offers a broad range of horizontal and vertical split case,

More information

Transformer oil cooler ALFA A02

Transformer oil cooler ALFA A02 A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using

More information

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?

More information

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE. SUBMERSIBLE PUMP selection A submersible pump consists of the following basic elements: < Bowl Assembly < Motor < Cable < Drop Pipe < Surface Plate (with)(without) discharge elbow DATA REQUIRED FOR SELECTION

More information

CRK 2-130 A-W-A-BUBV 85805906

CRK 2-130 A-W-A-BUBV 85805906 GRUNDFOS DATA BOOKLET CRK 2-13 A-W-A-BUBV 858596 Grundfos Pump 497113 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crk2/497113/crk-2-13-13-a-w-a-auuv.html

More information

3/2-way Mini Solenoid Valve

3/2-way Mini Solenoid Valve 3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug

More information

VERTICAL TURBINE AND PROPELLER PUMPS

VERTICAL TURBINE AND PROPELLER PUMPS VERTICAL TURBINE AND PROPELLER PUMPS INTRODUCTION Vertical Turbine and Propeller Pumps Model 7000 Series Turbine Pump Model 800 Series Axial Flow Propeller Pump Model 800 Series Mixed Flow Propeller Pump

More information

Heating, air-conditioning, cooling

Heating, air-conditioning, cooling Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft

More information

dp pumps the dynamics of water HVAC centrifugal (norm) pumps

dp pumps the dynamics of water HVAC centrifugal (norm) pumps dp pumps the dynamics of water HVAC centrifugal (norm) pumps 2 HVAC centrifugal (norm) pumps HVAC efficient solutions for comfortable living conditions To be comfortable in a building, both at home and

More information

BASIS RANGE TMB SERIES

BASIS RANGE TMB SERIES BASIS RANGE SERIES magnetic driven pumps BASIS The pumps belong to Argal s BASIS range and feature, single stage, centrifugal impeller and magnetic drive. The range of pumps includes five models to deliver

More information

Vertical Pumps for the Oil & Gas Industry

Vertical Pumps for the Oil & Gas Industry Vertical Pumps for the Oil & Gas Industry ITT API Expert ITT Commitment ITT is committed to the Oil and Gas market, which is the largest segment of our business. We have been investing in technology to

More information

AURORA. 1030 AND 1040 Series SUCTION DIFFUSERS, COMBINATION AND TRIPLE DUTY VALVES WWW.AURORAPUMP.COM

AURORA. 1030 AND 1040 Series SUCTION DIFFUSERS, COMBINATION AND TRIPLE DUTY VALVES WWW.AURORAPUMP.COM UROR 1030 ND 1040 Series SUCTION DIFFUSERS, COMINTION ND TRIPLE DUTY VLVES WWW.URORPUMP.COM UROR 1030 ND 1040 Series Suction Diffusers, Combination and Triple Duty Valves Designed for Direct Mounting on

More information

MFP14, MFP14S and MFP14SS Automatic Pumps

MFP14, MFP14S and MFP14SS Automatic Pumps Page 1 of 6 TI-P136-02 ST Issue 12 Cert. No. LRQ 0963008 ISO 9001, S and SS utomatic Pumps Description The Spirax Sarco automatic pump is a displacement receiver operated by steam or compressed air. It

More information

1.1 DIMENSIONS AND WEIGHT PAG. 2 1.2 LOAD CENTRE FOR LIFTING PAG. 2 1.3 STORAGE CONDITIONS PAG. 2

1.1 DIMENSIONS AND WEIGHT PAG. 2 1.2 LOAD CENTRE FOR LIFTING PAG. 2 1.3 STORAGE CONDITIONS PAG. 2 TRANSPORT AND INSTALLATION. DIMENSIONS AND WEIGHT PAG.. LOAD CENTRE FOR LIFTING PAG..3 STORAGE CONDITIONS PAG. STARTING. INSTALLATION PAG.. SPACE REQUIREMENTS PAG. 3.3 ELECTRIC CONNECTION PAG. 3 3 DESCRIPTION

More information

A technical guide to Shell tactic emv

A technical guide to Shell tactic emv A technical guide to Shell Tactic EMV TABLE OF CONTENTS SECTION PAGES Introduction 3 Benefits of Short Re-Lubrication Intervals 5 Contamination Prevention Strategies 6 Workplace Safety and Efficiency Gains

More information

4" SUBMERSIBLE PUMPS

4 SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 50/60 HZ Multi-stage centrifugal submersible pumps for clean water in 4" wells. The 4" VSP pump series is carefully designed and manufactured for maximum resistant

More information

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz VM, VMC, VMN Vertical Multistage Centrifugal Pump, 60Hz Approvals CERTIFICATE IQNet and SQS hereby certify that the organisation Swiss Pump Company AG 3645 Thun-Gwatt Switzerland Whole Company Design,

More information

Solenoid valves 2/2-way direct-operated Type EV210A

Solenoid valves 2/2-way direct-operated Type EV210A Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral

More information

! WARNING. Before using product, read and understand instructions.

! WARNING. Before using product, read and understand instructions. McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

AURORA. 110A Series "APCO" ONE AND TWO STAGE TURBINE PUMPS WWW.AURORAPUMP.COM

AURORA. 110A Series APCO ONE AND TWO STAGE TURBINE PUMPS WWW.AURORAPUMP.COM UROR 0 Series "PO" ONE N TWO STGE TURINE PUMPS WWW.URORPUMP.OM ONE N TWO STGE TURINE PUMPS UROR 0 Series "PO" One and Two Stage Turbine Pumps apacities to 0 G.P.M. Heads to 700 Feet Temperatures to 7 F

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron. D e s c r i p t i o n 500 The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron. A major feature of these

More information

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II 1 For your safety Table of Contents 1 For your safety... 3 1.1 About this manual... 3 1.2 Designated use... 3 1.3 Qualification

More information

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB Compact automatic flow rate regulator with polymer cartridge 127 series REGISTERED BS EN ISO 9001:2000 Cert. n FM 21654 UNI EN ISO 9001:2000 Cert. n 0003 CALEFFI 01166/09 GB Function The AUTOFLOW devices

More information

Pump Maintenance - Repair

Pump Maintenance - Repair Pump Maintenance - Repair Brian Trombly Mo Droppers Cummins Bridgeway, Gaylord, Mi The basic centrifugal pump consists of two main elements: 1. The rotating element which includes an impeller and a shaft.

More information

How To Pump A Pump

How To Pump A Pump Multistage Pumps P, PVa, MP 300 Technical Data Performance range: m Capacities up to 1800m 3 /h (8800USgpm) m Head up to 300m (1000feet) m Max. speed up to 1750rpm Multistage pumps of series MP with smaller

More information

WATER pressure. Issue 3 / 2014. Clear water pumps for domestic and commercial applications

WATER pressure. Issue 3 / 2014. Clear water pumps for domestic and commercial applications Issue 3 / 214 WATER pressure PUMPS AND washdown transfer pumps Clear water pumps for domestic and commercial applications Email: enquiries@dlmwallace.co.nz Web: www.dlmwallace.co.nz Auckland: Maurice Road,

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

Series DFMT Digital Paddlewheel Flowmeter

Series DFMT Digital Paddlewheel Flowmeter Series DFMT Digital Paddlewheel Flowmeter Bulletin F-DFMT Specifications - Installation Operating Instructions -/8 [00] -/ [8] -/8 [00] A The Series DFMT Digital Paddlewheel Flow Transmitter provides instantaneous

More information

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS PRINCIPLE OF OPERATION A hydraulically and dynamically balanced impeller with raised vane sections discharges liquid as a result of the centrifugal force developed in rotation. The head developed is entirely

More information

BOWIE PUMPS OPERATION - MAINTENANCE

BOWIE PUMPS OPERATION - MAINTENANCE BOWIE PUMPS OPERATION - MAINTENANCE PUMPING PRINCIPLE: The meshing owieeof the gears cause a slight depression, with the resulting enmeshing of the gears causing a vacuum drawing the fluid being pumped

More information

WATER & OIL 12/24v DC ELECTRIC CIRCULATION PUMPS

WATER & OIL 12/24v DC ELECTRIC CIRCULATION PUMPS WATER & OIL 12/24v DC ELECTRIC CIRCULATION PUMPS BAT Inc. 7630 Matoaka Road., Sarasota, FL. 34243 (941) 355-0005 fax (941) 355-4683 Heavy Duty Oil Scavenge/Circulation Pump When high temperature and continuous

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information