How To Get A Better Pay Out Of A Car
|
|
- Harry Powers
- 3 years ago
- Views:
Transcription
1 VA / V / V WET ROTOR CIRCUATORS VA V V TECNICA ATA Operating range: from. to 3, m3/h with head up to metres. Pumped liquid temperature range: from -1 C to +11 C. Pumped liquid: clean, free from solids and mineral oils, non viscous, chemically neutral, close to the characteristics of water (max 3% glycol). Maximum operating pressure: 1 bar (1 kpa). Minimum suction pressure: the values are given in the relative tables. Installation: with ORIZONTA MOTOR SAT on discharge or return pipe, with suction port as close as possible to expansion vessel, above maximum boiler level and as far as possible from bends, elbows, and circuit branches to avoid water turbulence with consequent noise. Protection level: corresponding to IP Insulation class: Cable groet: PG 11 Special executions on requests: alternative voltages and/or frequencies. Optional accessories: r 3 / / / M unions N-N-N3 oval counter-flanges N3/PN round counter-flanges APPICATIONS Pump for hot water circulation in domestic central heating and air conditioning systems of the closed circuit pressurized type or open circuit type. CONSTRUCTION EATURES Enbloc body composed of hydraulic section in cast iron and wet rotor motor. Motor casing in die cast aluminium. Impeller in technopolymer. Motor shaft in hardened stainless steel held in graphite bearings lubricated by the pumping medium. Rotor protective jacket, stator jacket, and closing flange in stainless steel. Ceramic thrust ring, ethylene-propylene seal rings and brass air breather plug. The two-pole asynchronous wet-rotor motor is resistance protected and does not require any form of overload protection. Three-speed operation. Protection rating: IP Insulation class: Cable gland: PG 11 Installation: with horizontal motor shaft. Standard voltage input: single-phase 3 V / z Special versions on request - alternative voltages and/or frequencies WET ROTOR CIRCUATORS A PUMPS reserves the right to make modifications without notice. 1
2 VA / V / V WET ROTOR CIRCUATORS MATERIAS N. PARTS MATERIAS PUMP OY CAST IRON IMPEER TECNOPOYMER 7A MOTOR SAT STAINESS STEE 7 ROTOR 13 7A STATOR 9 CAPACITOR 1 VA 1 MOTOR CASING IE CAST AUMINIUM 11 REATER PUG RASS WET ROTOR CIRCUATORS 1 TERMINA OX 17 SEA RING ETYENE POYPROPYENE 1 STATOR JACKET STAINESS STEE 19 ROTOR JACKET STAINESS STEE 13 COSING ANGE STAINESS STEE 131 TRUST RING SUPPORT ETYENE PROPYENE 13 7A USINGS GRAPITE 133 TRUST RING CERAMIC V egend: (example) VA / 1 X VA V V = single circulator = circulator with N oval flanges = twin circulator maximum head (dm) centre distance () standard (no ref.) 1 / X 3 = 1 1 / threaded ports = 1 threaded ports = threaded ports = N3/PN/1 flanged ports A PUMPS reserves the right to make modifications without notice. 1
3 VA / V / V WET ROTOR CIRCUATORS PERORMANCE RANGE 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. GRAPIC SEECTION TAE P kpa m, , Q US gpm Q IMP gpm ft A - - M P 3 WET ROTOR CIRCUATORS 3 3 M P 1 VA - V - V VS 1 1,1,,3,,, Q /h,1, Q l/s Q l/min A PUMPS reserves the right to make modifications without notice. 17
4 VA / V / V WET ROTOR CIRCUATORS SEECTION TAE - VA SINGE WIT UNIONS VA /13 Q= /h, 1, 1,, 3, Q=l/min 1 3 7,71,,1 1,7 1,, VA /1,71,,1 1,7 1,, VA /1X,71,,1 1,7 1,, VA 3/13,3 3,9 3,,,1 1, VA 3/13-1 /,3 3,9 3,,,1 1, VA 3/1,3 3,9 3,,,1 1, VA 3/1 X,3 3,9 3,,,1 1, VA /13 (m),,7, 3,3, 1,7, WET ROTOR CIRCUATORS VA /13-1 /,,7, 3,3, 1,7, VA /1,,7, 3,3, 1,7, VA /1 X,,7, 3,3, 1,7, VA /13,3,,3,3 3,, VA /13-1 /,3,,3,3 3,, VA /1,3,,3,3 3,, VA /1 X,3,,3,3 3,, SEECTION TAE - V SINGE WIT OVA ANGES V 3/1 Q= /h, 1, 1,, 3, Q=l/min 1 3 7,3 3,9 3,,,1 1, V /1 (m),,7 3,3, 1,7, V /1,3,,3,3 3,, SEECTION TAE - V TWIN WIT ANGES Q= /h, 1, 1,, 3, Q=l/min V /.3,,7, 3,3, 1,7, V /.3 (m),3,,3,3 3,, A PUMPS reserves the right to make modifications without notice. 1
5 VA /13 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h.... Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z VA / x3 V ~ 1 ¾ - 1¼ M UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A µ Vc t 9 3 3,19 3 3,17 1, m.c.a. 1, ,1 1 VA / , 7, 1, 7, ,7, VOUME WEIGT WET ROTOR CIRCUATORS VA /1 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h.... Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z VA /1 1 1x3 V ~ 1 ¾ - 1¼ M UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A µ Vc t 9 3 3,19 3 3,17 1, m.c.a. 1, ,1 1 VOUME WEIGT VA / , 7, 1, 7, ,37, A PUMPS reserves the right to make modifications without notice. 19
6 VA /1X - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h.... Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. WET ROTOR CIRCUATORS z VA /1X 1 1x3 V ~ 1 ¼ UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPEE 1/min W A µ Vc t 9 3 3,19 3 3,17 1, m.c.a. 1, ,1 1 VA /1X , 7, 1, 7, ,37, VOUME WEIGT VA 3/13 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h.... Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z VA 3/ x3 V ~ 1 ¾ - 1¼ M UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A µ Vc t 9 3, 193, 1,7 m.c.a. 1, ,1 1 VOUME WEIGT VA 3/ , 7, 1, 7, ,7, A PUMPS reserves the right to make modifications without notice. 11
7 VA 3/13-1 / - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h.... Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z VA 3/13-1 / 13 1x3 V ~ UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A µ Vc t 9 3, 193, 1,7 m.c.a. 1, ,1 1 VA 3/13-1 / , 7, 1, 7, ,7, VOUME WEIGT WET ROTOR CIRCUATORS VA 3/1 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h.... Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z VA 3/1 1 1x3 V ~ 1 ¾ - 1¼ M UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A µ Vc t 9 3, 193, 1,7 m.c.a. 1, ,1 1 VOUME WEIGT VA 3/ , 7, 1, 7, ,37, A PUMPS reserves the right to make modifications without notice. 111
8 VA 3/1X - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h.... Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. WET ROTOR CIRCUATORS z VA 3/1X 1 1x3 V ~ UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A µ Vc t 9 3, 193, 1,7 m.c.a. 1, ,1 1 VA 3/1X , 7, 1, 7, ,37, VOUME WEIGT VA /13 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z VA / x3 V ~ 1 ¾ - 1¼ M UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A µ Vc t 9 3 7,3 1, 1,7 m.c.a. 1, ,17 1 VOUME WEIGT VA / , 7, 1, 7, ,7, A PUMPS reserves the right to make modifications without notice. 11
9 VA /13-1 / - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z VA /13-1 / 13 1x3 V ~ UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A µ Vc t 9 3 7,3 1, 1,7 m.c.a. 1, ,17 1 VA /13-1 / , 7, 1, 7, ,7, VOUME WEIGT WET ROTOR CIRCUATORS VA /1 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z VA /1 1 1x3 V ~ 1 ¾ - 1¼ M UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A µ Vc t 9 3 7,3 1, 1,7 m.c.a. 1, ,17 1 VOUME WEIGT VA / , 7, 1, 7, ,37, A PUMPS reserves the right to make modifications without notice. 113
10 VA /1X - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. WET ROTOR CIRCUATORS z VA /1X 1 1x3 V ~ 1 ¼ UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPEE 1/min W A µ Vc t 9 3 7,3 1, 1,7 m.c.a. 1, ,17 1 VA /1X , 7, 1, 7, ,37, VOUME WEIGT VA /13 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z VA / x3 V ~ 1 ¾ - 1¼ M UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A µ Vc t ,3 13 9, m.c.a., 1 37,17 1 VOUME WEIGT VA / , 7, 1, 7, ,7, A PUMPS reserves the right to make modifications without notice. 11
11 VA /13-1 / - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z VA /13-1 / 13 1x3 V ~ UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A µ Vc t ,3 13 9, m.c.a., 1 37,17 1 VA /13-1 / , 7, 1, 7, ,7, VOUME WEIGT WET ROTOR CIRCUATORS VA /1 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z VA /1 1 1x3 V ~ 1 ¾ - 1¼ M UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A µ Vc t ,3 13 9, m.c.a., 1 37,17 1 VOUME WEIGT VA / , 7, 1, 7, ,37, A PUMPS reserves the right to make modifications without notice. 11
12 I I VA /1X - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. WET ROTOR CIRCUATORS z VA /1X 1 1x3 V ~ 1 ¼ UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPEE 1/min W A µ Vc t ,3 13 9, m.c.a., 1 37,17 1 VA /1X , 7, 1, 7, ,37, VOUME WEIGT V 3/1 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm 1 1 Q IMP gpm m t Q /h.... Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z V 3/1 1 1x3 V ~ N UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A t 9 µ Vc 3, N 193, 1,7 m.c.a. 1, N ,1 1 1 I VOUME WEIGT V 3/ M ,7,7 A PUMPS reserves the right to make modifications without notice. 11
13 I I I I V /1 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z V /1 1 1x3 V ~ N UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A t 9 µ Vc 3 7,3 N 1, 1,7 m.c.a. 1, N , I V / M ,7,7 VOUME WEIGT WET ROTOR CIRCUATORS V /1 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z V /1 1 1x3 V ~ N UNIONS ON REQUEST EECTRICA ATA MINIMUM SUCTION PRESSURE STANARISE SPECIA SPEE 1/min W A t 9 µ Vc ,3 N 13 9, m.c.a., N ,17 1 I 1 VOUME WEIGT V / M ,7,7 A PUMPS reserves the right to make modifications without notice. 117
14 V /.3 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. WET ROTOR CIRCUATORS z UNIONS ON REQUEST V /.3 1x3 V ~ N 3 / PN / PN 1 SPEE 3 1 REV. 1/min 1 93 EECTRICA ATA P1 MAX W In A 7,3, 3,17 CAPACITOR µ Vc MINIMUM SUCTION PRESSURE t 9 1,7 m.c.a. 1, 1 1 PN PN1 PN PN1 V / , 1, ,9, VOUME WEIGT V /.3 - EATING AN AIR CONITIONING SYSTEMS Pumped liquid temperature range: from -1 C to +11 C - Maximum operating pressure: 1 bar (1 kpa) Q US gpm Q IMP gpm m t Q /h Q l/sec 1 3 Q l/min 1 /s and density equal to 1 /. Curve tolerance according to ISO 99. z UNIONS ON REQUEST V /.3 1x3 V ~ N 3 / PN / PN 1 SPEE 3 1 REV. 1/min EECTRICA ATA P1 MAX W In A 7,3 9, 37,17 MINIMUM SUCTION PRESSURE CAPACITOR t 9 µ Vc m.c.a., 1 1 PN PN1 PN PN1 VOUME WEIGT V /.3 91, 1, ,9, A PUMPS reserves the right to make modifications without notice. 11
2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS
2CP Twin-impeller pumps PERFORMANCE RANGE Flow rate up to 40 l/min (27 m³/h) Head up to 112 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C Ambient temperature
More informationCDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100
CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 90 203 PERFORMANCE CHART 120 204 PERFORMANCE CHART 200 205 - CONSTRUCTIONS 300 SECTIONAL
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS
More informationSIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:
OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND
More informationThe Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,
The Company QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design, manufacturing and service needs in the field of submersible pumps. Our engineering
More informationRPT SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS 426 2.98 23.01
SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS RPT SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +4 581 661 111, fax: +4 581 602 587 Email: sigmahra@sigmahra.cz 426
More information1.0 2.0 3.0 4.0 5.0 6.0 7.0. Q [m 3 /h] Wilo-Star Cast iron body 60 Hz. Star 30 F. Star 21. Star 17 FX. 4 8 12 16 20 24 28 Q [US gpm]
Product review: Range: Wilo-Star....... Star F Star Star Star F Star Star FX [m /h] Wilo-Star Cast iron body Hz [US gpm].......... [m /h] Wilo-Star Bronze body 9 Hz [US gpm] Star Star Star Star Star BF
More informationCRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html
More informationCRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ
GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html
More informationPump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationLaing industrial pumps
Laing industrial pumps... with spherical motor, robust and reliable! Normal suction centrifugal pumps! Self-priming pumps! Ecocirc DC pumps Summary Chapter Page Normal suction centrifugal pumps... 3 Application...
More informationPump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationSJT / SJM / SJP Large Vertical Pumps
SJT / SJM / SJP Large Vertical Pumps The Heart of Your Process SJT, SJM, SJP Large Vertical Pumps Product Overview SJT Turbine Ns 1800 < 5000 nq 35 < 110 SJM Mixed Flow Ns 5800 < 8300 nq 113 < 161 SJP
More informationSIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS 426 2.98 12.06
SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS LV SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +420 581 661 111, fax: +420 581 602 587 Email: sigmahra@sigmahra.cz
More informationSeries description: Wilo-Star-Z
H[m] Series description: Wilo-Star-Z 4 3 Wilo-Star-Z Star-Z 2/5 2/4 2 1 Star St ar- Z1 5T Design Glandless circulation pump with threaded connection Application Potable water circulation systems in industry
More informationErgo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
More informationHorizontal Jet Pumps 1/3-1-1/2 HP
Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The
More informationSeries description: Wilo-Yonos MAXO
16 88 / Series description: Wilo-Yonos MAXO /,5-1 1 Wilo-Yonos MAXO 1 5/,5-1 8 6 /,5-5/3/,5-7 5/3/,5-1 /5/,5-8 65/,5-9 5/,5-9 5/3/,5-1 5 1 15 5 Design Glandless circulation pump with threaded connection
More informationMEMBRANE VACUUM MINI PUMPS
MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free
More informationMax. Head (m) LVR3-7-220V 3 32 5 44 0,55 10 50Hz ~ 220 V Oval Flange G1. LVR3-7-380V 3 32 5 44 0,55 10 50Hz ~ 380 V Oval Flange G1
Description NordicFlow s keep the system pressurized during normal conditions and prevent unnecessary activation of the main pump. They have compact design, high efficiency, low noise, reliable sealing
More informationThe conditions below apply to the curves shown on the following pages.
GENERAL INFORMATION STAINLESS STEEL, SILVERLINE, EVERGREEN & GOLDLINE SERIES PERFORMANCE CURVE CONDITIONS The conditions below apply to the curves shown on the following pages. a. The Performance curves
More informationPUMP AND MOTOR DIVISION
INSTALLATION MANUAL SERIES P2 and P3 MOBILE PISTON PUMP 1 Check model code / compare with your paper work Nameplate of the pump Ordering / Sales Acknowledgement 2 Check rotation of the pump Clockwise rotation
More informationSeries description: Wilo-Yonos MAXO-D
ATAC Solutions LTD / 1 / Series description: 1 /,5-1 1 5/,5-1 3/,5-7 3 3 5/ /, / 11 5-,5-,5-9 Design Glandless circulation pump with threaded connection or flange connection, EC motor with automatic power
More informationVertical Multistage Centrifugal Electric Pumps SV2-4-8-16 Series NEW LASER TECHNOLOGY
Vertical Multistage Centrifugal Electric Pumps SV2-4-8-16 Series NEW LASER TECHNOLOGY TYPICAL APPLICATIONS Water supply Transfer and distribution from water systems Pressure boosting in apartment buildings
More informationSeries description: Wilo-Drain TC 40
Series description: Wilo-Drain TC 40 H[m] Wilo-Drain TC 40 10 8 6 4 2 TC 40/8 TC 40/10 0 0 2 4 6 8 10 12 14 Q[m³/h] Design Submersible sewage pump Application Pumping heavily contaminated fluids for House/site
More informationRules for Classification and Construction Additional Rules and Guidelines
VI Rules for Classification and Construction Additional Rules and Guidelines 5 Pumps 1 Guidelines for the Design, Construction and Testing of Pumps Edition 2007 The following Guidelines come into force
More informationSVA SIGMA PUMPY HRANICE SELF PRIMING PUMPS 426 2.98 16.05
SIGMA PUMPY HRANICE SELF PRIMING PUMPS SVA SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +40 581 661 111, fax: +40 581 60 587 Email: sigmahra@sigmahra.cz 46.98 16.05 Applications
More informationDry Pit Solids Handling Pumps
Dry Pit Solids Handling Pumps A Time-Tested Leader Chicago Pump Dry Pit Solids Handling Pumps have an established reputation of efficiency, long life and reliable operation First in: Quality 3Reliability
More informationPump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages
Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages 2448LSG_P1 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationFlygt N-Pumps 3085, 3102 & 3127. For reliable and efficient wastewater handling
Flygt N-Pumps 3085, 3102 & 3127 For reliable and efficient wastewater handling The Concept Flygt N-Pump series Reduced pumping efficiency, high energy and maintenance costs shouldn t be a fact of life
More informationEcocirc, EB, EBV, TLCB, TLCHB Series
Hz Ecocirc, EB, EBV, TLCB, TLCHB Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS ErP 9//EC Cod. 97 Rev ev.a.a Ed./ Lowara is a trademark of Lowara srl Unipersonale, subsidiary of
More informationTurbine Flow Sensor Series VTR
Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates
More informationQPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems
The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system
More informationHow To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationMARKET SECTORS CIVIL, AGRICULTURAL, INDUSTRIAL.
Twin- Impeller Centrifugal Electric Pumps CA-CA(N) Series Standard supplied IE2 motors are compliant with Regulation (EC) no. 640/2009. MARKET SECTORS CIVIL, AGRICULTURAL, INDUSTRIAL. APPLICATIONS Version
More informationINLINE SD-PUMPS WITH IEC-STANDARD MOTOR
INLINE SD-PUMPS WITH IEC-STANDARD MOTOR AT_-1/ Hz DN1 3 r/min min H G 1/ G 1/ 17 11 3xM, Depth 1 1 Ø1 Ø1 xø19 7 3xØ1 9 17 1 xø1 17 1 kw A kg H OKN-13 E1 F19 7. (9). 9 OKN-13 C1 F19. (.) 11. 1 9 OKN-1 E1
More informationSIGMA GROUP a. s. Divize průmyslová čerpadla
SIGMA GROUP a. s. Divize průmyslová čerpadla SIGMA GROUP a. s. INDUSTRIAL PUMP DIVISION Jana Sigmunda 79, 783 50 LUTÍN SEWAGE PUMPS NFPH, NFVH, NFJH, NFRH, NFPV, NFVV, NFJV, NFRV, NFPW NFVW Tel.: +420
More informationSeated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange
Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications. The
More informationOUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter
D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from
More informationModel 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com
Model 62A MODEL 41A MODEL 44A AURORA 40A/60A Series SINGLE STAGE END PUMPS www.aurorapump.com SINGLE STAGE END PUMPS AURORA 40A/60A Series Single Stage End Suction Pumps Capacities to 4500 G.P.M. (1022
More informationOperating instructions Mechatronic flow sensor. SBY33x 704465/06 03/2011
Operating instructions Mechatronic flow sensor SBY33x 7065/06 03/2011 Contents 1 Safety instructions...2 2 Functions and features...3 3 Installation...3 Electrical connection... 5 Switch point setting...
More informationZOP, ZOT SIGMA PUMPY HRANICE GEAR PUMPS 426 1.99 21.04
SIGMA UMY HRANICE GEAR UMS SIGMA UMY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +420 581 661 111, fax: +420 581 602 587 Email: sigmahra@sigmahra.cz, 426 1.99 21.04 Application In
More informationProduct Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz
Product Catalogue ETX, Stainless steel threaded centrifugal pumps, Hz Contents Introduction... ETX... Choosing the right pump There are a wide range of pumps to select from. In order to find the right
More informationConlift1, Conlift2, Conlift2 ph+
GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications
More informationOUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.
Our Other Products OUR PRODUCTS Liquid Ring & Rotary Vane Vacuum Pumps and Systems Liquid Ring Vacuum Pumps: 3 CFM to,000 CFM Liquid Ring Compressors up to 1 psig Heat Transfer Pumps for hot thermal oils
More information08.08 Vic-Check Valves
The check valves are a product of computer-assisted innovative engineering with quality features including a new hydrodynamically efficient profile. The Vic-Check valve utilizes a spring-assisted, single-disc
More informationTECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP
TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:
More informationButterfly Valves PN 6/10/16 for flanged connection
4 136 ACVATIX Butterfly Valves PN 6/10/16 for flanged connection tight-closing VKF46.. VKF46..TS Grey cast iron housing EN-GJL-250 (to DN 300) nodular cast iron housing EN-GJS-400-15 (from DN 350) DN 40
More informationKTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet
KTZ32.2-5 data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str.6 40472 Düsseldorf Germany Tel.: +49-2-479373 Fax: +49-2-479429
More informationMultistage high-pressure multistage centrifugal pumps
Series description Wilo-Helix V 2 4 6 8 Wilo-Helix V 19-27 7 6 6 Hz - North America 22 2 18 5 16 14 4 12 3 1 V 1 V 19 V 27 8 2 6 1 5 1 15 2 25 3 4 2 35Q[US gpm] H[ft] H[m] Design Vertical multi-stage,
More informationFlygt 3068, 50Hz. Technical Specification
Flygt 3068, 50Hz Technical Specification Table of Contents Table of Contents B-pump...2 Product description...2 Motor rating and performance curves...4 C-pump...6 Product description...6 Motor rating
More information50/60 Hz. ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS. ErP 2009/125/EC. Cod.
/ Hz ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS ErP 9//EC Cod. 9 Rev ev.a.a Ed./ ecocirc BASIC SERIES INSTALLA ALLATION POSITIONS Lowara, ecocirc, Xylect are trademarks
More informationJOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.
Redi-Flo2, 2 Environmental Submersible Pumps MP1 Submittal Data QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS Technical Data Motor Type: Water-Filled, variable speed submersible Maximum Fluid
More informationModel 1210C Battery Powered Pump Shown. Description
12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with
More informationSUPER-TITAN. Split-case pumps with power, performance and reliability for a world of applications
SUPER-TITAN Split-case pumps with power, performance and reliability for a world of applications The Prestige. The Performance. SUPER-TITAN PUMPS Features The TKL Super-Titan pump makes a significant contribution
More informationREVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)
SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY
More informationCatalogue Wilo- Stratos PARA
Heating, ir Condition, Cooling, Geothermal heat, Solar heat 25-50W 100W 200W Catalogue Wilo- Stratos PR Wilo-Stratos PR 15/1-5; 20/1-5; 25/1-5; 30/1-5 Wilo-Stratos PR 15/1-7; 20/1-7; 25/1-7; 30/1-7 Wilo-Stratos
More informationGRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps
GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA/UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance
More informationInstructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version
instrumentation for fluids Electromagnetic sensor Series FLOMID FX Instructions Manual! Conforms with the Pressure Equipment Directive 97/23/EC. 0830 This equipment is considered as being a pressure accessory
More informationVertical selfpriming Side-Channel Pumps Type WPV
Vertical selfpriming Side-Channel Pumps Type WPV FIELD OF APPLICATION The side-channel pumps are selfpriming and operate more economically (better efficiency) than normal centrifugal pumps when handling
More information2- and 3-port valves with flanged connections, PN 10
4 402 VVF32.. VXF32.. ACVATIX 2 and 3port valves with flanged connections, PN 10 From the largestroke valve line VVF32.. VXF32.. Performance valves for medium temperatures from 10 150 C Valve body of grey
More informationSCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.
SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of
More informationGlobo P. Ball valves Pump ball valve made of gunmetal
Globo Ball valves ump ball valve made of gunmetal IMI EIMEIER / Shut-off valves / Globo Globo Globo and Globo -S are used in pump warm water heating systems for direct connection to circulating pumps with
More informationMULTISTAGE CENTRIFUGAL PUMPS
MULTISTAGE CENTRIFUGAL PUMPS MULTISTAGE CENTRIFUGAL PUMPS TK - TKR - VTK - TKK series TK-VTK-TKR-TKK are high pressure multistage pumps. Connection to the driving machine (generally an electrical motor)
More informationPumps SELECTION OF A PUMP
Pumps SELECTION OF A PUMP A water system needs to move the water produced from the source to its customers. In almost all cases in Minnesota, the source is at a lower elevation than the user so the water
More informationSlide 1. Slide 2. Slide 3 288,817,200,000. Thank you for attending the session on Hot Water Re-Circulation.
Slide 1 Thank you for attending the session on Hot Water Re-Circulation. Hot Water Re-Circulation National Conference Center Lansdowne, VA March 25 th & 26 th, 2010 Slide 2 AGENDA Water Waste Statistics
More informationFAIRBANKS NIJHUIS FIRE PUMPS. www.fairbanksnijhuis.com
FAIRBANKS NIJHUIS FIRE PUMPS www.fairbanksnijhuis.com FAIRBANKS NIJHUIS Long established as a leading fire pump manufacturer, Fairbanks Nijhuis offers a broad range of horizontal and vertical split case,
More informationTransformer oil cooler ALFA A02
A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using
More information2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications
Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?
More informationBOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.
SUBMERSIBLE PUMP selection A submersible pump consists of the following basic elements: < Bowl Assembly < Motor < Cable < Drop Pipe < Surface Plate (with)(without) discharge elbow DATA REQUIRED FOR SELECTION
More informationCRK 2-130 A-W-A-BUBV 85805906
GRUNDFOS DATA BOOKLET CRK 2-13 A-W-A-BUBV 858596 Grundfos Pump 497113 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crk2/497113/crk-2-13-13-a-w-a-auuv.html
More information3/2-way Mini Solenoid Valve
3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug
More informationVERTICAL TURBINE AND PROPELLER PUMPS
VERTICAL TURBINE AND PROPELLER PUMPS INTRODUCTION Vertical Turbine and Propeller Pumps Model 7000 Series Turbine Pump Model 800 Series Axial Flow Propeller Pump Model 800 Series Mixed Flow Propeller Pump
More informationHeating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
More informationdp pumps the dynamics of water HVAC centrifugal (norm) pumps
dp pumps the dynamics of water HVAC centrifugal (norm) pumps 2 HVAC centrifugal (norm) pumps HVAC efficient solutions for comfortable living conditions To be comfortable in a building, both at home and
More informationBASIS RANGE TMB SERIES
BASIS RANGE SERIES magnetic driven pumps BASIS The pumps belong to Argal s BASIS range and feature, single stage, centrifugal impeller and magnetic drive. The range of pumps includes five models to deliver
More informationVertical Pumps for the Oil & Gas Industry
Vertical Pumps for the Oil & Gas Industry ITT API Expert ITT Commitment ITT is committed to the Oil and Gas market, which is the largest segment of our business. We have been investing in technology to
More informationAURORA. 1030 AND 1040 Series SUCTION DIFFUSERS, COMBINATION AND TRIPLE DUTY VALVES WWW.AURORAPUMP.COM
UROR 1030 ND 1040 Series SUCTION DIFFUSERS, COMINTION ND TRIPLE DUTY VLVES WWW.URORPUMP.COM UROR 1030 ND 1040 Series Suction Diffusers, Combination and Triple Duty Valves Designed for Direct Mounting on
More informationMFP14, MFP14S and MFP14SS Automatic Pumps
Page 1 of 6 TI-P136-02 ST Issue 12 Cert. No. LRQ 0963008 ISO 9001, S and SS utomatic Pumps Description The Spirax Sarco automatic pump is a displacement receiver operated by steam or compressed air. It
More information1.1 DIMENSIONS AND WEIGHT PAG. 2 1.2 LOAD CENTRE FOR LIFTING PAG. 2 1.3 STORAGE CONDITIONS PAG. 2
TRANSPORT AND INSTALLATION. DIMENSIONS AND WEIGHT PAG.. LOAD CENTRE FOR LIFTING PAG..3 STORAGE CONDITIONS PAG. STARTING. INSTALLATION PAG.. SPACE REQUIREMENTS PAG. 3.3 ELECTRIC CONNECTION PAG. 3 3 DESCRIPTION
More informationA technical guide to Shell tactic emv
A technical guide to Shell Tactic EMV TABLE OF CONTENTS SECTION PAGES Introduction 3 Benefits of Short Re-Lubrication Intervals 5 Contamination Prevention Strategies 6 Workplace Safety and Efficiency Gains
More information4" SUBMERSIBLE PUMPS
4" SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 50/60 HZ Multi-stage centrifugal submersible pumps for clean water in 4" wells. The 4" VSP pump series is carefully designed and manufactured for maximum resistant
More informationVM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz
VM, VMC, VMN Vertical Multistage Centrifugal Pump, 60Hz Approvals CERTIFICATE IQNet and SQS hereby certify that the organisation Swiss Pump Company AG 3645 Thun-Gwatt Switzerland Whole Company Design,
More informationSolenoid valves 2/2-way direct-operated Type EV210A
Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral
More information! WARNING. Before using product, read and understand instructions.
McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes
More information3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
More informationAURORA. 110A Series "APCO" ONE AND TWO STAGE TURBINE PUMPS WWW.AURORAPUMP.COM
UROR 0 Series "PO" ONE N TWO STGE TURINE PUMPS WWW.URORPUMP.OM ONE N TWO STGE TURINE PUMPS UROR 0 Series "PO" One and Two Stage Turbine Pumps apacities to 0 G.P.M. Heads to 700 Feet Temperatures to 7 F
More informationArt.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
More informationThe SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.
D e s c r i p t i o n 500 The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron. A major feature of these
More informationInstallation and Commissioning Manual Solar Stations FlowCon Max Evolution II
Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II 1 For your safety Table of Contents 1 For your safety... 3 1.1 About this manual... 3 1.2 Designated use... 3 1.3 Qualification
More informationCALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB
Compact automatic flow rate regulator with polymer cartridge 127 series REGISTERED BS EN ISO 9001:2000 Cert. n FM 21654 UNI EN ISO 9001:2000 Cert. n 0003 CALEFFI 01166/09 GB Function The AUTOFLOW devices
More informationPump Maintenance - Repair
Pump Maintenance - Repair Brian Trombly Mo Droppers Cummins Bridgeway, Gaylord, Mi The basic centrifugal pump consists of two main elements: 1. The rotating element which includes an impeller and a shaft.
More informationHow To Pump A Pump
Multistage Pumps P, PVa, MP 300 Technical Data Performance range: m Capacities up to 1800m 3 /h (8800USgpm) m Head up to 300m (1000feet) m Max. speed up to 1750rpm Multistage pumps of series MP with smaller
More informationWATER pressure. Issue 3 / 2014. Clear water pumps for domestic and commercial applications
Issue 3 / 214 WATER pressure PUMPS AND washdown transfer pumps Clear water pumps for domestic and commercial applications Email: enquiries@dlmwallace.co.nz Web: www.dlmwallace.co.nz Auckland: Maurice Road,
More informationAssisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
More informationSeries DFMT Digital Paddlewheel Flowmeter
Series DFMT Digital Paddlewheel Flowmeter Bulletin F-DFMT Specifications - Installation Operating Instructions -/8 [00] -/ [8] -/8 [00] A The Series DFMT Digital Paddlewheel Flow Transmitter provides instantaneous
More informationBSM MOTOR DRIVEN CENTRIFUGAL PUMPS
PRINCIPLE OF OPERATION A hydraulically and dynamically balanced impeller with raised vane sections discharges liquid as a result of the centrifugal force developed in rotation. The head developed is entirely
More informationBOWIE PUMPS OPERATION - MAINTENANCE
BOWIE PUMPS OPERATION - MAINTENANCE PUMPING PRINCIPLE: The meshing owieeof the gears cause a slight depression, with the resulting enmeshing of the gears causing a vacuum drawing the fluid being pumped
More informationWATER & OIL 12/24v DC ELECTRIC CIRCULATION PUMPS
WATER & OIL 12/24v DC ELECTRIC CIRCULATION PUMPS BAT Inc. 7630 Matoaka Road., Sarasota, FL. 34243 (941) 355-0005 fax (941) 355-4683 Heavy Duty Oil Scavenge/Circulation Pump When high temperature and continuous
More informationFluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
More information