Model: EB-50GU-A Standard Package
|
|
- Alannah Holmes
- 7 years ago
- Views:
Transcription
1 Model: EB-50GU-A Standard Package Job Name: Schedule Reference: Date: EB-50GU-A STANDARD PACKAGE EB-50GU-A Centralized Controller PAC-SC51KUA Power Supply Monitoring Annual and Weekly Scheduling, Sending Error , Online Maintenance Tool, Interlock Control and Data Monitoring OPTIONAL SOFTWARE SW-Charge: Tenant Billing - Calculates per tenant CITY MULTI energy usage based on the refrigerant capacity used of the outdoor unit(s) divided among the associated indoor units - Requires TG-2000 software Ver or later installed on a dedicated, networked PC connected to a RS-485 watt hour meter (WHM) SW-PWeb: Online Personal Browser - Allows individual users (up to 50) to control their respective zone conditions via personal networked PC with or without local remote controllers installed in the space EB-50GU-A CENTRALIZED CONTROLLER SPECIFICATIONS Manages up to 50 Indoor Units individually, in a group or in a collective batch operation Supports dual set point functionality (connected model dependent) Displays: - CITY MULTI compressor speed and hi/low pressure - Advanced HVAC Controller (DC-A2IO) input/output status - Indoor unit free contact input/output status - Space Temperature and Humidity (from Smart ME or AI controller) - Error code - Unoccupied setback up temperature range Functions - Hold function (temporarily disables schedules indoor unit model dependent) - Initial setting - Operation data back-up Permits or prohibits remote controller functions: - On/Off - Change Operation Mode - Change Set point Temperature - Filter Status - Change Fan Speed - Change Air Direction External input/output signals can be used for batch operations such as Start/Stop and Emergency Stop (Requires PAC-YG10HA) Temperature set point range limits can be set for local remote controllers User defined indoor unit functions: - On/Off - Monitoring and Operation - Operation mode: Auto* (Dual or Single set point) Cool Heat Fan Drying Setback* Note: *R2 Series only (connected equipment dependent) Temperature Setting Fan Speed Airflow Direction Monitoring and Control: - CITY MULTI indoor units - M & P Series units (Requires M-Net adapter) - Lossnay units - PWFY hydronic heat pump units - DIDO controllers - CITY MULTI DOAS - Interlock setting enables integration of general equipment inputs/outputs and indoor units Scheduling - Daily - Annually - Five pattern weekly seasonal schedule Twenty four scheduled events per day, indoor unit model dependent: - ON/OFF - Mode - Temperature Setting - Vane Direction - Fan - Speed - Operation Prohibits Trend data: - Fan operation time - Thermo-on time - Set temperature - Room temperature - AI Controller temperature and humidity (Requires PAC-YG63 MCA, 2 inputs total for each controller)
2 Models: EB-50GU-A - System Configuration 4. System configuration The figure below only shows the transmission cable connections. Power cables are omitted. Power supply unit PAC-SC51KUA (sold separately) Power (24 VDC) outdoor unit (Y) Centralized controller EB-50 [000] LAN AHC Indoor unit Local remote controller Advanced HVAC CONTROLLER transmission cable remote controller cable TB7 [051] TB3 Group 2 Group 1 Numbers in the parentheses indicate address numbers. [004] [005] [001] [002] [003] outdoor unit (R2) TB7 [056] [057] TB3 BC controller Group 3 LOSSNAY [006] [007] [008] [009] [010] ME [106] AHC [201] Mr. Slim/M- and P-Series outdoor unit Mr. Slim/M- and P-Series outdoor unit [11] [12] adapter Group 4 Group 5 14 Fig. 4-1
3 EB-50GU-A Centralized Controller Model: EB-50GU-A - Specifications Specifications Power Supply Controller Drive 24VDC ± 5% *Power Supply: PAC-SC51KUA Operating Range -10 C +55 C [+14 F +131 F] Temperature Environmental Conditions Non-operating Range -20 C +60 C [-4 F +140 F] Humidity 30-90% RH (No condensation) Weight 2 lbs. (0.7 kg) Dimensions (W x H x D) 6-1/2 4-3/4 1-13/16 in. ( mm) Web Browser Requirements CPU Memory Screen Resolution Compatible Browser Windows Macintosh Onboard LAN Port or LAN Card Other Requirements 1 GHz or faster 512 MB or more 1024 x 768 or higher recommended Microsoft Internet Explorer 8.0 Microsoft Internet Explorer 9.0 * Java execution environment is required. (Oracle Java Plug-in Ver _11) * Install Oracle Java Plug-in that is appropriate for your operating system. When using a 64-bit Internet Explorer, install a 64-bit Java Plug-in. * The version of the Oracle Java Plug-in can be verified by clicking [Java] in the Control Panel. Safari 6 * Java execution environment is required. (Oracle Java Plug-in Ver _11) * The version of the Oracle Java Plug-in can be verified by clicking [Help]-[Installed Plug-ins] on the Safari browser. One connector (100BASE-TX) Pointing device such as a mouse.
4 External dimension Model: EB-50GU-A - Dimensions Unit:mm[in.] 225 (8-7/8) 205 (8-3/32) 165 (6-1/2) 46 (1-13/16) 50 (1-31/32) 60 (2-3/8) 120 (4-3/4) L-fitting 30 (1-3/16) 10 (13/32) 4.5 (3/16) 4.5 (3/16) 36 (1-7/16) Notes:
5 POWER SUPPLY (PAC-SC51KUA) SPECIFICATIONS Source Power Requirements Output Voltage / Current Load Capacity Environmental Conditions Dimensions (H x W x D) Weight Model: PAC-SC51KUA Rated input voltage and current: VAC ±10 %; 0.8A 0.4A; 50Hz/60Hz single-phase. Fuse: 6.3A time delay type. Output voltage/current: : VDC; DC power supply: 24VDC ±5% A. Dimensions: (H x W x D) 6-11/16 x 10-11/16 x 2-7/8. Weight: 3-1/8 lbs. Indoor installation in field-supplied control panel or surface mount attachment (sold separately). Installation Environment Specifications Rated Input Voltage / VAC ±10%; 0.8A - 0.4A, 50/60Hz Current single phase Fuse: 6.3 time delay type (IEC127-2 S.S.5) VDC DC Power Supply 24VDC ±5%; A One EB-50GU-A Centralized Controller Operating Range F ( C) Temperature F (-20 - Storage Range +60 C) Humidity 30-90% RH (no condensation) 6-11/16 x 10-11/16 x 2-7/8" (169 x 271 x 72mm) 3-1/8 lbs. (1.4kg) Indoor installation in field-supplied control panel or surface mount attachment (sold separately). PAC-SC51KUA POWER SUPPLY DIMENSIONS 271 (10-11 /16) 90 (3-9 /16) 72 (2-7 / 8) 130 (5-1 / 8) 155 (6-1 / 8) 169 (6-11 / 16) T TB2,TB3 TB1 FORM# EB-50GU-A Standard Package Satellite Boulevard Suwanee, GA Tele: Fax: Toll Free:
Model: DC-A2IO Advanced HVAC Controller
Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA
More informationAir Conditioning Control System Centralized Controller AE-200A/AE-50A AE-200E/AE-50E Instruction Book Web Browser for Initial Settings
Air Conditioning Control System Centralized Controller AE-200A/AE-50A AE-200E/AE-50E Instruction Book Web Browser for Initial Settings Contents 1. Introduction...2 1-1. Terms Used in This Manual...2 1-2.
More informationTemperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
More informationCommunication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities.
Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities. More Freedom to Administrators Connectable up to 128 Indoor Unit Groups (256 indoor
More informationCentral Controller G-50A/GB-50A Web Browser Operation Manual (For System Maintenance Engineer)
Mitsubishi Electric Building Air-conditioner Control System Central Controller G-50A/GB-50A Web Browser Operation Manual (For System Maintenance Engineer) Contents 1 Introduction...1 1-1 Conventions Used
More informationCLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability
PFD-P250VM-E PUHY-P250YJM-A(-BS) PUHY-P500YSJM-A(-BS) PQHY-P250YHM-A CLOSE CONTROL SYSTEM MITSUBISHI ELECTRIC s Close Control System (PFD series) is specifically designed for computer rooms, laboratories
More informationPower supply unit Model: PAC-SC50KUA
Building Air Conditioning Control System Power supply unit Model: PAC-SC50KUA Installation Manual Contents 1. Safety precautions... 1 2. Product feature... 2 1. Specification... 2 2. Appearance... 2 3.
More informationIntesisBox KNX LG Air Conditioning
IntesisBox KNX LG Air Conditioning Gateway for integration of LG Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB) bus. Direct connection to LG outdoor unit
More informationsip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved
Sanyo Section : Section : Section : Section : Section : sip Modbus Guide Configuration Modbus Table Technical Specification Pinouts, Cable Connections & Wiring Alarm Fault Codes Issue : February 009 Section
More informationResearch RF Sputtering Packages
Research RF Sputtering Packages Shown with 3" Polaris Adjustable Position Source with Tilt and Shutter 300 or 600 Watt Low Cost Packages for Those With Limited Budgets Desiring Full Capability 13.56 MHz
More informationQuick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Table of Contents Introduction.. Power Over Ethernet (PoE) & Features.... Unpacking and
More informationTrueAlarm Fire Alarm Systems
TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Fire Alarm System Accessories, 4190 Series PC Annunciator with Multi-Client Capability Features Fire alarm control
More informationThe THERMOSTAT THE EVOLUTION OF CAPABILITIES INTO A PLATFORM FOR ENERGY MANAGEMENT
The THERMOSTAT THE EVOLUTION OF CAPABILITIES INTO A PLATFORM FOR ENERGY MANAGEMENT Presented by: Michael Kuhlmann President Residential Control Systems Inc The Basics Thermostat Functions Measure Room
More informationElectronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
More informationLGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34) 985 113 339 tecnico@ingeniumsl.com
Integrations LGAC-KNX V1.0 PROGRAMMING MANUAL Parque Tecnológico de Asturias, Parcela 50, 33428 Llanera Asturias - Spain Tel (+34) 985 118 859 Fax (+34) 984 283 560 ingeniumsl@ingeniumsl.com www.ingeniumsl.com
More informationIntesisBox Modbus Server - Mitsubishi Electric G50
IntesisBox Server - Mitsubishi Electric G50 Gateway for monitor and control Mitsubishi Electric City Multi Air Conditioning systems from any master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel )
More informationIntesisBox KNX Mitsubishi Heavy Industries AC
IntesisBox KNX Mitsubishi Heavy Industries AC Gateway for integration of Mitsubishi Heavy Indsutries (MHI) Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB)
More informationDISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual
Infrastructure Management & Monitoring For Business-Critical Continuity Liebert icom-do User Manual TABLE OF CONTENTS 1.0 INTRODUCTION............................... 1 2.0 INSTALLATION...............................
More informationKNX Panasonic Air Conditioners
IntesisBox KNX Panasonic Air Conditioners Gateway for Panasonic ECOi and PACi system integration into KNX networks Up to 30 Outdoor units Up to 64 Indoor units PA-AC-KNX-64/128 EIA485 U1U2 line U1U2 line
More informationMulti-Range Programmable DC Power Supplies 9115 Series
Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional
More informationWorkshop 7 PC Software - Tracker
Workshop 7 PC Software - Tracker Goal: You will startup and perform advanced setup functions using Tracker PC software. You will also setup equations to control MP503 binary outputs. The Binary Output
More informationElectronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
More informationIntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.
IntesisBox KNX SAMSUNG Air Conditioning Gateway for integration of Samsung air conditioners into KNX control systems. Integrate Samsung Air Conditioners into KNX. KNX EIB Bus IntesisBox RS485 MIM-B13x/B04A
More informationREGULINE 600VA / 1000VA REGULATOR USER MANUAL
REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate
More informationR22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power
R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor
More informationModbus Server SAMSUNG Air Conditioners
IntesisBox Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung Air Conditioning Systems from any master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel ) Master TCP Master
More informationCentralized Controller Model: AG-150A
Air-conditioner Network System Centralized Controller Model: AG-150A Contents Instruction Book (Web browser for Initial Settings) 1 Introduction...1 1-1 Terms Used in This Manual... 1 1-2 Computer Requirements...
More informationzseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s
TECHNICAL SPECIFICATIONS zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s 2015 LitePoint, A Teradyne Company. All rights reserved. The LitePoint zseries 18-slot chassis is an
More informationPRODUCT LIST Facility DDC Access WebXL DDC
PRODUCT LIST Facility DDC Access WebXL DDC Effective from 01/10/2014 Sphere Systems Pty Ltd Unit 6 / 9 Mirra Crt Bundoora Victoria Australia 3083 ABN 98 006 579 004 Phone +61 3 9470 8844 Fax +61 3 9470
More information8-Port PoE Network Switch
Page 1 of 12 8-Port PoE Network Switch User s Guide Document Number 91I00-1 Rev A August, 2009 FCC Warning: Page 2 of 12 This devices has been tested and found to comply with the regulations for Class
More information3.5in esata USB Dual Removable SATA RAID External Hard Drive Enclosure StarTech ID: S352U2RER
3.5in esata USB Dual Removable SATA RAID External Hard Drive Enclosure StarTech ID: S352U2RER This esata/usb External Dual SATA Hot-swap Hard Drive Enclosure lets you install two 3.5in SATA (SATA, SATA
More informationJNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More informationThyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
More informationDuct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
More informationIntesisBox Modbus Server SAMSUNG Air Conditioners
IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,
More informationVariable Air Volume - VAV
Mode Enable Sensor Options Variable Air Volume - VAV The temperature of this sensor will determine if the unit is in heating, cooling or vent mode during occupied operation. The following options are available:
More informationDCS Series 1 kw, 1.2 kw, & 3 kw
DCS Series 1 kw, 1.2 kw, & 3 kw AVAILABLE WITH LXI STANDARD COMPLIANT ETHERNET Applications Automotive Electronics Rackmount ATE System Battery Charging DCS Series DCS Series: 1 kw, 1.2 kw, & 3 kw DCS
More informationMAJORSINE Power Inverter
MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions
More information4-CH Hybrid Digital Video Recorder
4-CH Hybrid Digital Video Recorder Key Features Hardware Embedded, highly-reliable standalone HDVR Supports 4-ch BNC connectors Supports dual local display (VGA and HDMI) Supports 3.5" SATA x 1 HDD Supports
More informationHD WIRELESS VIDEO SECURITY SYSTEM WIRELESS CONVENIENCE, HIGH DEFINITION QUALITY
HD WIRELESS LH0412W, LH04141TC2W, LH04141TC2WP, LH04141TC2WB LH0414WB, LH04141TC4W, LH04141TC4WP WIRELESS CONVENIENCE, HIGH DEFINITION QUALITY Experience crystal clear HD 720p video day or night. No need
More informationData Loggers for Real Time Temperature Monitoring - WiFi
Data Loggers for Real Time Temperature Monitoring - WiFi Main Features Complete standalone system. Even if computer/network does not operate the recording system will continue to record without any interruption.
More informationCommunicate and view data from meters with one simple device
Communicate and view data from meters with one simple device PowerLogic EGX300 integrated gateway-server Web Monitoring Communications Plug and Play Plug into your energy usage with a simple mouse click
More informationENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM
ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM MAKING SMART TOWNS, BUILDING SMART COMMUNITIES WHY PANASONIC? RESIDENTIAL STORAGE BATTERY SYSTEM The next evolution in solar energy solutions. Panasonic
More informationCE6500 Energy Recovery Ventilator
ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge
More informationNetwork Video Recorder
Network Video Recorder XC-4CH-NVR-1TB and XC-8CH-NVR-2TB Username: admin Password: 12345 Quick Operation Guide XC-4CH-NVR-1TB and XC-8CH-NVR-2TB quick guide TABLE OF CONTENTS NVR Pre-Installation... 2
More informationAPC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,
More informationCisco 7816-I5 Media Convergence Server
Cisco 7816-I5 Media Convergence Server Cisco Unified Communications Solutions unify voice, video, data, and mobile applications on fixed and mobile networks, enabling easy collaboration every time from
More informationPower Proportional Distribution (PPD)
1. Description The feature supplies the user with a reasonably calculated apportionment of the total power consumption by the Daikin air-conditioning system to individual indoor units in the system. Because
More informationDATA/SPEC SHEET VIRTUAL MATRIX DISPLAY CONTROLLER VERSION 8
DATA/SPEC SHEET VIRTUAL MATRIX DISPLAY CONTROLLER VERSION 8 V920 - PRODUCT DESCRIPTION Virtual Matrix Display Controller The Virtual Matrix Display Controller (VMDC) is a selfcontained, matrix control
More information1.44 kw Programmable DC Power Supplies XLN Series
Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable
More informationTAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM
TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution
More informationWATCH OVER YOUR WORLD FROM ANYWHERE IN THE WORLD
WATCH OVER YOUR WORLD FROM ANYWHERE IN THE WORLD THE VERSATILE SOLUTION TO PROTECT YOUR HOME OR BUSINESS INSTANT REMOTE CONNECTIVITY DAY & NIGHT, INDOOR/OUTDOOR REAL-TIME RECORDING UP TO 9 MONTHS EXPANDABLE
More informationComputer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC
Technical Teaching Equipment Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC Teaching Technique used EDIBON SCADA System 2 Control Interface Box 5 Cables and Accessories 6 Manuals 3
More informationSales Bulletin #CT016a
Sales Bulletin #CT016a Date: June 5, 2014 To: Daikin Sales, Service, and Distribution Subject: The intelligent Touch Manager (itm) Version 2.0 Daikin is pleased to announce the release of its new software
More informationRack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
More informationTemperature & Humidity SMS Alert Controller
Smart Energy Control... Temperature & Humidity SMS Alert Controller Energy Saving, Environment & Proper es Protec on 2 temperature sensors or 1 x temperature & 1 x humidity sensor Keep track of temperature
More informationOutdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
More informationCisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem
Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem The Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem (DPC3010) provides DOCSIS broadband service providers with a cost-effective solution for delivering high-speed
More informationAIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass
AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass APC AIS 3000, 12 kw / 15 kva,input 208V 3PH / Output 120V, 208V, 208V 3PH, Interface Port DB-9 RS-232,
More information100 240VAC 50/60Hz Power Adapter
DGS-1224T D-Link 24-Port 10/100/1000Mbps + 2 Combo Mini GBIC Gigabit Smart Switch Broadband Router Before Your Begin This Quick Installation Guide gives step-by-step instructions for setting up the D -Link
More informationNETWORK SOLUTIONS. www.daikin.eu
NETWORK SOLUTIONS www.daikin.eu A l l o w s d e ta i l e d a n d e a s y m o n i t o r i n g a n d o p e r at i o n o f V R V s y s t e m s ( m a x i m u m 2 x 6 4 g r o u p s / i n d o o r u n i t s )
More informationTo ensure you have the appropriate equipment and settings please review the following: Software and Hardware Recommendations.
Step 2- Computer Check Before you attempt to login to University resources it is important to make sure your computer will support an online course, or an accelerated course with an online component. It
More informationChassis, Power Supply, and Element Management
Chassis, Power Supply, and Element Management C-COR CHP Max5000 Converged Headend Platform Accelerate deployment of new, revenue generating advanced services Innovative technology creating converged high-
More informationVOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421
VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications...1 2-2 Electrical Specifications... 2 3. FRONT PANEL DESCRIPTION... 4 3-1
More informationXIV. Electrical / Electronics
Mobile Climate Control 261 MCC Reference Manual 2014 Temperature Controllers Mini Vehicle Controller P/N: 35-0748 P/N: 35-8071 Specifications Operating Voltage: Operating Temperature: Inputs: Outputs:
More informationSpecifications for the Gateway M1300 Tablet PC
Specifications for the Gateway M1300 Tablet PC Specifications are subject to change without notice or obligation. Processor and Core Logic Processor options Chipset Processor packaging Level 2 cache Core
More informationElectric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions
Self-Retracts 30 ft. Charge Cable Length Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions Safe, Convenient & Clean EV Charging The EVoReel cable management solutions
More informationSECURITY CAMERA SYSTEM
SECURITY CAMERA SYSTEM WATCH OVER YOUR WORLD FROM ANYWHERE IN THE WORLD PROFESSIONAL-GRADE VIDEO SURVEILLANCE A high quality system connecting you to your entire property, expandable up to 16 cameras.
More informationFROM ANYWHERE IN THE WORLD
WATCH OVER YOUR WORLD FROM ANYWHERE IN THE WORLD Remote Connectivity & Compatibility iphone ipad 8/16 CHANNELS 1TB OR 2TB 960H PREMIUM SERIES ADVANCED 960H RECORDING RESOLUTION MAC & PC INTERNET MONITORING
More informationApplication Server V240 Platform
Application Server V240 Platform The V240 Application Server (V240) features four hot-swappable disks with redundant power supplies for reliable system performance. The server also has three PCI slots
More informationBasic Specifications. Electrical. EPSON Perfection 3170. Color EPSON MatrixCCD TM line sensor. device Effective pixels
Scanner Parts Document table Power cord Document cover Transparency unit (TPU) under lid Web Transparency unit (TPU) connector TPU indicator light e-mail Carriage and lamp (in the home position) USB port
More informationRecording. http://www.qnap.com/nvr/compatibilityx01.html. Smart recording (depending on the camera models)
VS-2108L Hardware Spec. CPU Marvell 1.6GHz DRAM 512MB DDRIII RAM Flash Memory 512MB Hard Disk Drive 2 x 3.5" SATA I/II hard disk drive (HDD) NOTE: 1. The system is shipped without hard disk drives. 2.
More informationHCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply
1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,
More informationGain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server
Gain energy insight and control with PowerLogic PowerLogic EGX300 integrated gateway-server Plug into your energy usage with a simple mouse click The PowerLogic EGX300 is an integrated gateway-server that
More informationThe Totaline Premier Series of thermostats consists of programmable and non programmable air conditioner, heat pump and thermidistat control.
The Totaline Premier Series of thermostats consists of programmable and non programmable air conditioner, heat pump and thermidistat control. These units feature mercury free non lead based electronic
More informationZlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
More informationSage Grant Management System Requirements
Sage Grant Management System Requirements You should meet or exceed the following system requirements: One Server - Database/Web Server The following system requirements are for Sage Grant Management to
More informationIntesisBox KNX Modbus RTU master
IntesisBox KNX RTU master Gateway for integration of RTU devices into KNX control systems. Integrate RTU devices (Chillers, Roof Tops, electricity meters, heating floors, heat pumps, PLCs ) into KNX control
More informationRISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
More informationT-6232 10 Zone Weekly Timer
Economy 10 Zone BGM Solution for School and Factory Zone 1 Microphone cable T-105 5" Ceiling Speaker Aux cable Speaker cable T-6232 (with SD input) 10 Zone Weekly Timer Zone 2 T-601 6W Wall Mount Speaker
More informationDaker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
More informationTelephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
More informationTHE NEW 4X8 PANEL PCs INNOVATIVE HMI TECHNOLOGY FOR HAZARDOUS AREAS
THE NEW 4X8 PANEL PCs INNOVATIVE HMI TECHNOLOGY FOR HAZARDOUS AREAS WWW.EXICOM.DE 1 The latest in PC technology specially designed for the oil and gas industries 2 2 WWW.STAHL-HMI.DE The new 4X8 Panel
More informationSMS GSM Alarm Messenger
SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up
More information2 1. 5 O pen F ram e Tou c h M on i t or
M TM G T- R TL 2 2 W- A 21.5" RE AR TOU C H MONITOR Trade SpA - Official European Distributor R eo O ar M ount R T L 1 7 3 2 1. 5 O pen F ram e Tou c h M on i t or R TL 2 2 W- A on i t or D at as h eet
More informationNetwork Video Recorder Quick Operation Guide
Network Video Recorder Quick Operation Guide UD.6L0202B1119A01 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable
More informationQuickSpecs. HP Compaq t5525 Thin Client. Overview
Overview 1. 10/100 RJ-45 6. PS/2 Connector 2. Security lock 7. DC Power Input 3. Parallel Connector 8. Video Connector 4. USB Connectors 9. Serial Connector 5. Audio connector (mic in/line out) DA - 12265
More informationOverview of the Cisco 2500 Series Access Server
CHAPTER 1 Overview of the Cisco 2500 Series Access Server The Cisco 2500 series access server is a full-featured communication server with multiprotocol routing capability between synchronous serial, LAN,
More informationSympodium Interactive Pen Display
Physical Specifications Sympodium Interactive Pen Display Specifications Model DT770 Size Display Area Weight Shipping Size Shipping Weight (Carton and Contents) 19" W 18" H 3 5/8" D (48.3 cm 45.7 cm 9.2
More information543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
More information1. Introduction. 2. Components. 3. Optical Specifications. 4. Electric Specifications. 5. Dimension. 6. Operating Environment. 7.
SPECIFICATIONS Super Model: XHS-220S1 Class Solar Simulator 1. Introduction 2. Components 3. Optical Specifications 4. Electric Specifications 5. Dimension 6. Operating Environment 7. Warranty SAN-EI ELECTRIC
More informationBM ADAPTER Model: BAC-HD150
Air-conditioner Control System BM ADAPTER Model: BAC-HD150 Installation Manual Contents Page Safety Precautions... 2 1. Specifications... 4 1-1. Product Specifications... 4 1-2. External dimensions...
More informationMegapixall Security Tools & Accessories
Megapixall Security Tools & Accessories Table of Contents Code Product Page MPIX-POEINJ Single Port POE 30w Injector 3 MPIX-POE4 8 Port POE switch, 4 Ports of POE 4 MPIX-POE8 8 Port POE Switch with 1 Gigabit
More informationwww.smarcom.biz BARCODE TICKET SOLUTION RF CARD SOLUTION MAGNETIC TICKET SOLUTION
BARCODE TICKET SOLUTION RF CARD SOLUTION MAGNETIC TICKET SOLUTION C A R PA R K M A N A G E M E N T S Y S T E M C A R Barcode ticket application PA R K M A N A G E M E N T S Y S T E M RF card application
More informationwww.inspection-for-industry.com
Quality Control Form (TEST RUNNING RECORD FOR AIR HANDLING UNIT) SUB POWER SUPPLY: MAIN POWER V, Hz, CONTROL V, Blower 1 kw, Blower 2 kw, Compressor: (1) kw (2) kw (3) kw (4) kw Heating Element: kw 1.
More informationNetwork Video Recorder Quick Operation Guide
Network Video Recorder Quick Operation Guide UD.6L0202B1283A01 TABLE OF CONTENTS NVR Pre-Installation... 2 NVR Installation... 2 Hard Disk Installation... 2 Front Panel... 4 Rear Panel... 5 Specifications...
More informationTABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C
Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the
More informationPRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE
Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface
More informationSmart Thermostat page 1
Smart Thermostat page 1 3. APPROACH In today s home appliances market, automation is becoming the norm and Smart Thermostat is a typical automation appliance able to be applied easily at home. With Smart
More informationTrueAlarm Fire Alarm Systems
TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es
More information