1040 Sliding Mall Front

Size: px
Start display at page:

Download "1040 Sliding Mall Front"

Transcription

1 JULY, 0 EC Sliding Mall Front INDEX ELEVATIONS/VERTICAL SECTION DETAILS... HORIZONTAL SECTION DETAILS... EGRESS DOOR... - STACK AREA LAYOUT... - SIZE LIMITATIONS... HARDWARE...0 Kawneer Company, Inc., 00 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. The following metric (SI ) units are found in these details: m meter cm centimeter mm millimeter s second Pa pascal MPa megapascal Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. ADMB00EN

2 00 Sliding Mall Front ELEVATIONS/VERTICAL SECTION DETAILS JULY, 0 EC -0 SCALE " = '-0" *POSSIBLE CONDITION VARY WIDELY. CONSULT THE KAWNEER REPRESENTATIVE FOR APPLICATION NOT SHOWN IN THESE DETAILS. ELEVATIONS ARE NUMBERED KEYED BELOW AND ON PAGE. -/" /" (.) /" (.) SURFACE HEAD APPLICATION HEAD /" (.) -/" WEATHERING ANGLE OPTIONAL RECESSED HEAD APPLICATION HEAD /" (.) -/" 0 RECESSED HEAD APPLICATION HEAD /" (.) -/" NOTE: FOR PROPER OPERATION ON SURFACE APPLICATIONS, THE FINISH FLOOR MUST BE LEVEL WITHIN /" PER EACH WIDTH AND WITHIN /" OVER THE ENTIRE AREA. NOTE: PROPER SUPPORT MUST BE PROVIDED FOR FLOOR AND HEAD INCLUDING THE STACK AREA. /" (.) RAMP ADAPTER -/" (.) -/" (.) -/" (.) BOTTOM SURFACE SILL -/" (.) MIN. CHASE DEPTH -/" (.) -/" -/" (.) -/" MIN. CHASE WIDTH (.) INTERMEDIATE HORIZONTAL -/" (.) -/" BOTTOM RECESSED SILL SUPPORT - COMPRESSIBLE SHIM FINISH FLOOR -/ (.0) / (.) NOM. 0-0 DRAIN TUBE INTERMEDIATE HORIZONTAL BOTTOM DRAINING / (.) NOM. (.) MIN CHASE DEPTH DRAIN SUPPORT Kawneer Company, Inc., 00 DRAIN CONNECTIONS TO 0-0 TO BE BY OTHERS " (.) TO -/"(.) O.D. DRAIN TUBING RECOMMENDED EVERY ' (. METERS) AND AT EACH END. / MIN. CHASE WIDTH (.) ADMB00EN

3 JULY, 0 EC Sliding Mall Front HORIZONTAL SECTION DETAILS SCALE " = '-0" C L *-/ (.) -/ (.) C L -/ (.) CLOSING NOT BY KAWNEER. DESIGN MUST CONSIDER RELATIVE LOCATION OF STACK -/ -/ (0.) -/ (.) -/ NARROW TERMINATOR IS REQUIRED. WHEN LAST IS LOCKED IN PLACE BY HINGED OF STORAGE POCKET. / (.) -/ (.) -/ -/ (.) -/ (.) -/ -/ (0.) -/ (.) -/ *-/"(.) ALLOWS FOR CHASE ONLY. JOB DESIGN MUST ALLOW FOR CLEARANCE BETWEEN / CLOSURE DOOR AND MOVING (.) S. NOM. TERMINATOR STILE C L TERMINATOR STILE -/ (.) / (.) RECEIVING JAMB ASSEMBLY -/ -/ / (.) (.) / (.) NOM. -/ RECESSED JAMB CHANNEL / (.) ALTERNATE SURFACE APPLIED JAMB CHANNEL SHIM AS REQUIRED TO PLUM RECEIVING JAMB / (.) -/ (.) -/ (.) Kawneer Company, Inc., 00 TERMINATOR STILE C L -/ (.) -/ (.) -/ (0.) -/ (.) -/" / NOM. -/ (.) -/" MEETING STILES -/ -/ RECEIVING JAMB ASSEMBLY W/ SIDELIGHT MEETING STILES FOR 0 TWO WAY STACK -/ (0.) -/ (0.) -/ (.) -/ (.) 0 NOTE: CYLINDER LOCKS SHOWN FOR ILLUSTRATION ON LY (SPECIFY EXACT LOCATION.) ADMB00EN

4 00 Sliding Mall Front EGRESS DOOR SCALE " = '-0" NOTE: REFER TO PAGES 0 AND FOR STANDARD 00 SLIDING MALL FRONT DETAILS. JULY, 0 EC -0 0 ELEVATIONS ARE NUMBERED KEYED BELOW AND ON PAGE. -/" /" (.) OPTIONAL /" (.) SURFACE HEAD APPLICATION /" (.) -/" HEAD STANDARD CLEARANCE / (.) -/ / (.) OPTIONAL 0 SURFACE HEAD APPLICATION HEAD / (.) -/ -/ / (.) STANDARD CLEARANCE DOOR DOOR OPENING RAMP ADAPTER /" (.) /" (.) /" (.) -/" (.) -/ -/ -/" (.) -/ -/" (.) TRANSOM DOOR DOOR BOTTOM SURFACE SILL NOTE: TO COMPLY WITH /" MAX. THRESHOLD HEIGHT AT EGRESS DOOR, SURFACE OF FLOOR MUST BE FLUSH WITH FINISHED FLOOR. FINISH FLOOR -/ (.) - COMPRESSIBLE SHIM MIN. CHASE DEPTH -/ -/ (.) -/ / MIN. CHASE WIDTH (.) BOTTOM / (.) RECESSED SUPPORT Kawneer Company, Inc., 00 ADMB00EN

5 JULY, 0 EC -0 SCALE " = '-0" 00 Sliding Mall Front EGRESS DOOR ELEVATIONS ARE NUMBER KEYED TO DETAILS -/ (.) DOOR OPENING -/ -/ TERMINATOR STILE DOOR HINGE STILE -/ (.) STILE DOOR HINGE STILE -/ (.) -/ -/ -/ -/ -/ DOOR OPENING 0 STILE -/ (.) DOOR LOCK STILE STILE -/ (.) STILE DOOR LOCK STILE DOOR LOCK STILE STILE Kawneer Company, Inc., 00. Maximum door opening width: (Per Uniform Building Code) "(.) - (" (.) clear at 0 degrees).. Maximum door opening width: " (0.) (requires sidelight and/or transom for stability).. Minimum door opening height: (Per Uniform Building Code) 0" (0).. Maximum door opening height: 0" (). Maximum threshold height: (Per uniform Building Code) /" (.).. Door cannot be hinged off of sidelight.. Minimum light opening width of sidelight: /" (.).. Maximum light opening width of sidelight: " (.).. Standard Hardware: Reference Page for hardware information). EGRESS DOOR LIMITATIONS/ HARDWARE 0. Optional Hardware: A. Thumbturn inside in lieu of cylinder. B. Adams Rite 0 latchlock with handle in lieu of A.R.M.S.0 A. C. Adams Rite 0 exit indicator. D. Cylinder guard. E. Flush pull in door. Note: When using optional hardware, due to its greater projection, the placement of the exit panel in the stack is critical to prevent interference with adjacent panels.. Not available: A. Closers. B. Panic Decives. C. Push-pull Hardware. A. Walking beam top pivot with modified center bottom pivot. B. Adams Rite M.S. 0 A lock with two () cyclinders. D. Pairs of doors or double sidelighted units.. Door is not intended for use by general public.. Door is to be locked closed before moving panel. ADMB00EN

6 00 Sliding Mall Front STACK AREA LAYOUT JULY, 0 EC -0 PARALLEL STAGGERED STACK WIDTH NO. OF S '-"/'-0" (/) -/" x " (0 x ) -/" x " ( x 0) -/" x " ( x ) -/" x 0 ( x 0) -/" x " (0 x ) -/"x " ( x 0) -/" x " ( x 0) '-0"/'" (/0) -/" x " ( x ) -/" x " ( x 0) -/" x " (0 x ) 0-/" x 0" ( x 0) -/" x " ( x ) -/" x " ( x 0) -/" x " (0 x 0) '-"/'-0" (0/) -/" x " ( x ) -/" x " ( x 0) -/" x " ( x ) -/" x 0" ( x 0) -/" x " (0 x ) -/" x " ( x 0) -/" x " ( x 0) '-0"/'-" (/) -/" x " ( x ) 0-/" x " ( x 0) -/" x " ( X ) -/" x 0" ( x 0) -/" x " ( x ) -/" x " ( x 0) -/" x " (0 x 0) '-"/'-0" (/) -/" x " ( x ) -/" x " ( x 0) -/" x " ( x ) -/" x 0" ( x 0) -/" x " 0 x ) 0-/" x " (0 x 0) -/" x " (0 x 0) '-0"/'" (/) -/" x " (0 x ) -/" x " (0 x 0) -/" x " ( x ) -/" x 0" ( x 0 -/" x " ( x ) -/" x " ( x 0) -/" x " ( x 0) '-"/'-0" (/) -/" x " ( x ) -/" x " ( x 0) -/" x " ( x ) 0-/" x 0" ( x 0) -/" x " ( x ) -/" x " ( x 0) -/" x " ( x 0) '-0"/'-" (/) -/" x " ( x ) -/" x " (00 x 0) -/" x " ( x ) -/" x 0" ( x 0 -/" x " ( x ) -/" x " ( x 0) -/" x " ( x 0) '-"/'-0" (x) -/" x " ( x ) 00-/" x " ( x 0) 0-/" x " ( x ) 0-/" x 0" (00 x 0) 0-/" x " ( x ) 0-/" x " ( x 0) 0-/" x " ( x 0) 0 -/" x " ( x ) -/" x " ( x ) 0-/" x " ( x ) -/" x " ( x ) -/" x " (0 x ) -/" x " ( x ) -/" x " ( x ) 00-/" x " ( x ) 0-/" x " ( x ) D CLOSET WALL W REFER TO LAYOUT CHART ABOVE FOR "W" AND "D" DIMENSIONS. -/ (.) STANDARD C L CLEAR OPENING -/ (.) MINIMUM Kawneer Company, Inc., 00 NOTE:. CHASE AREA MUST BE A MINIMUM OF -/" (.) DEEP.. STACK AREA MUST BE ACCESSIBLE FOR MAINTENANCE AND CLEANING. ADMB00EN

7 JULY, 0 EC Sliding Mall Front STACK AREA LAYOUT PARALLEL EVEN STACK WIDTH* NO. OF S '-" / '-0" ( / ) " x " ( x ) '-0" / '" ( / 0) 0-/" x " ( x ) '-" / '-0" (0 / ) -/" x " (0 x ) -/" x " ( x 0) -/" x " ( x ) '-0" / '-" ( / ) -/" x " ( x ) -/" x " ( x 0) -/" x " ( x ) -/" x 0" ( x 0) -/" x " (x) '-" / '-0" ( / ) -/" x " (0 x ) -/" x " (0 x 0) -/" x " (0 x ) -/" x 0" (0 x 0) -/" x " (0 x ) -/" x " ( x 0) -/" x " ( x 0) '-0" / '" ( / ) -/" x " ( x ) -/" x " ( x 0) -/" x " ( x ) -/" x 0" ( x 0) -/" x " ( x ) -/" x " ( x 0) -/" x " ( x 0) '-" / '-0" ( / ) -/" x " (0 x ) -/" x " (0 x 0) -/" x " (0 x 0) -/" x 0" (0 x 0) -/" x " (0 x ) -/" x " (0 x 0) -/" x " (0 x 0) '-0" / '-" ( / ) -/" x " ( x ) -/" x " ( x 0) -/" x " ( x ) -/" x 0" ( x 0) -/" x " ( x ) -/" x " ( x 0) -/" x " ( x 0) '-" / '-0" ( x ) -/ x " ( x ) -/" x " ( x 0) -/" x " ( x ) -/" x 0" ( x 0 -/" x " ( x ) -/" x " ( x 0) -/" x " ( x 0) 0 -/" x " ( x ) -/" x " (0 x ) -/" x " ( x ) -/" x " ( x ) *THE CASTER SPACING DIMENSION SHOWN BELOW SHOULD BE AT LEAST / OF THE HEIGHT. THE CASTER VARIES FROM A EDGE BY -/" FOR S AS SHOWN PLUS ABOUT " FOR EACH ADDITIONAL. Kawneer Company, Inc., 00 D CLOSET WALL CASTER SPACING W REFER TO LAYOUT CHART ABOVE FOR "W" AND "D" DIMENSIONS. -/ (.) STANDARD C L CLEAR OPENING -/ (.) MINIMUM NOTE:. CHASE AREA MUST BE A MINIMUM OF -/" (.) DEEP.. STACK AREA MUST BE ACCESSIBLE FOR MAINTENANCE AND CLEANING.. MAXIMUM NUMBER OF S FOR THIS STACK AREA DEPENDS UPON WIDTHS. CONTACT FACTORY REPRESENTATIVE.. EDGE PULLS REQUIRED ON LAST TWO S INTO STACK AREA. ADMB00EN

8 00 Sliding Mall Front STACK AREA LAYOUT JULY, 0 EC -0 0 STACK NO. OF S 0 '-"/'-0" ( / ) -/" x -/" ( x ) -/" x -/" ( x ) -/" x -/" ( x 0) -/" x 0-/" ( x ) -/" x -/" ( x 0) -/" x -/" ( x ) -/" x -/" ( x ) -/" x -/" ( x 0) '-0"/'" ( / 0) -/" x -/" ( x ) -/" x -/" (x ) -/"x-/" (x) -/"x-/" (x) -/"X-/" (X) -/"x-/" (x) -/"x-/" (x0) -/"x0-/" (x) '-"/'-0" (0 / ) -/" x -/" ( x ) -/" x 0-/" ( x ) -/" x -/" ( x ) -/" x -/" ( x ) -/" x -/" ( x ) -/" x -/" ( x ) -/" x -/" ( x ) -/" x -/" ( x ) '-0"/'-" ( / ) -/" x -/" ( x 0) -/" x -/" ( x ) -/" x -/" ( x ) -/" x -/" ( x ) -/" x -/" ( x ) -/" x 0-/" ( x ) -/" x -/" ( x ) -/" x -/" ( x ) WIDTH '-"/'-0" ( / ) -/" x -/" ( x ) -/" x -/" ( x ) -/" x -/" ( x 0) -/" x -/" ( x ) -/" x -/" ( x ) -/ x -/" ( x ) -/" x -/" ( x ) -/" x -/" ( x ) '-0"/'" ( / ) -/" x -/" ( x ) -/" x -/" ( x ) -/" x -/" ( x 0) -/" x 0-/" ( x 0) -/" x -/" ( x 00) -/" x -/" ( x 0) -/" x -/" ( x ) -/" x -/" ( x ) '-"/'-0" ( / ) -/" x -/" ( x ) -/" x -/" ( x ) -/" x -/" ( x ) -/" x -/" ( x ) -/" x -/" ( x ) -/" x -/" ( x ) -/" x -/" ( x 0) -/" x 0-/" ( x ) '-0"/'-" ( / ) -/" x -/" ( x 0) -/" x 0-/" ( x 0) -/" x -/" ( x ) -/" x -/" ( x ) -/" x -/" ( x ) -/" x -/" ( x ) -/" x -/" (x ) -/" x -/" ( x ) '-"/'-0" ( x ) -/" x -/" ( x ) -/" x -/" ( x ) -/" x -/" ( x 0) -/" x -/" ( x 0) -/" x -/" ( x ) -/" x 00-/" ( x ) -/" x 0-/" ( x ) -/" x 0-/" ( x ) D DIM C -/ STANDARD C L MIN. STACK OPENING '" (0.) -/ (.) MINIMUM DIM E WIDTH IN FEET CLEARANCE (DIM. C.) (.)(.) 0 () 0 () (0.) (.) (0.) 0 (0) 0 () STACK OPENING (DIM. E.).. MIN. STACK OPENING " (.) EXAMPLE: A ' WIDTH WITH AN " CLEARANCE (DIM. C) WOULD REQUIRE A 0" STACK OPENING (DIM. "E.) (.) WIDTH IN METERS Kawneer Company, Inc., 00 W CLEAR OPENING NOTE:. CHASE AREA MUST BE A MINIMUM OF -/" (.) DEEP.. STACK AREA MUST BE ACCESSIBLE FOR MAINTENANCE AND CLEANING. ADMB00EN

9 JULY, 0 EC Sliding Mall Front SIZE LIMITATIONS/GENERAL INFORMATION Mullions are designed for /0 deflection ratio. These curve are for mullions WITH and WITHOUT HORIZONTALS and are based on precise engineering calculations for stress, deflection and buckling. Allowable windload stress for Aluminum, P.S.I. ( MPa) STEEL, P.S.I, ( MPa). Charted curves in all cases are for the limiting value. For special situations not covered by the curves, contact your Kawneer representative for additional information. MAXIMUM SIZE LIMITATIONS HEIGHT IN FEET 0 EXTERIOR APPLICATION DEFLECTIONS L/0 WIDTH IN METERS I=. (. x 0 ) S=.0(. x 0 ).... HEIGHT IN METERS A = PSF (0 PA) B = 0 PSF (0 Pa) C = PSF (00 Pa) HEIGHT IN FEET 0 INTERIOR APPLICATION (WINDLOAD NOT APPLICABLE) WIDTH IN METERS I=. (. x 0 ) S=.0(. x 0 ).... HEIGHT IN METERS 0 0 WIDTH IN FEET WIDTH IN FEET Kawneer Company, Inc., 00 NOTE:. WIDTHS (CATER SPACING) SHOULD BE AT LEAST / OF HEIGHT FOR ROLLING STABILITY THE MAJOR EXCEPTION TO THIS RULE IS THE PARALLEL EVEN STACK LAYOUT (SEE ASTERISK ON PAGE OF SECTION B). ON S OVER 0' IN HEIGHT AN INTERMEDIATE HORIZONTAL MOUNTING IS RECOMMENDED. GENERAL INFORMATION GENERAL DESCRIPTION: THE "00" SLIDING FRONT CONSISTS OF SINGLE AGE WITH MULTIPLE STACKING OPTIONS FOR INTERIOR OR EXTERIOR APPLICATIONS. IT IS IDEALLY SUITED FOR THE FOLLOWING COMMERCIAL APPLICATIONS: ENCLOSED SHOPPING MALLS EXTERIOR MOVEABLE WALLS AUTOMOBILE SHOWROOMS SLIDING ROOM DIVIDERS EDUCATIONAL MOVEABLE PARTITIONS INSTITUTIONAL SLIDING DOORS ADMB00EN

10 0 00 Sliding Mall Front HARDWARE JULY, 0 EC HARDWARE EDGE PULL OUTBOARD RECESSED CASTER FACE PULL (OPTIONAL) MS 0A LOCK INBOARD CASTER INBOARD HEAD GUIDE OUTBOARD RECESSED HEAD GUIDE Kawneer Company, Inc., 00 REFER TO HARDWARE SECTION FOR INFORMATION ON ADAMS RITE 0 LATCHLOCK, 0 LEVER HANDLE AND 0 EXIT INDICATOR USED OPTIONALLY ON THE EGRESS DOOR. ADMB00EN

1070 SLIDING MALL FRONT

1070 SLIDING MALL FRONT 70 SLIDING MALL FRONT INDEX 1 PICTORIAL VIEW.................................... ELEVATION / VERTICAL SECTION DETAILS................ HORIZONTAL SECTION DETAILS...................... 5 STACK AREA LAYOUT...............................

More information

Frame The fixed parts of the window or door. The frame includes the head jambs, sill and mullions. The frame does not include the sash.

Frame The fixed parts of the window or door. The frame includes the head jambs, sill and mullions. The frame does not include the sash. Terminology, Cross Sections & Profiles Frame The fixed parts of the window or door. The frame includes the head jambs, sill and mullions. The frame does not include the sash. Stile Sash Head Frame Jamb

More information

Features. Optional Features

Features. Optional Features AUGUST, 2006 190/350/500 STANDARD ENTRANCES 1 FEATURES Features 190 narrow stile has 2-1/8" vertical stile, 2-1/4" top and 3-7/8" bottom rail 350 medium stile has 3-1/2" vertical stile, 3-1/2" top and

More information

glass entrance systems

glass entrance systems All Glass Entrance Systems: Entrance Configurations/Fitting Designations og-43410 og-47210 og-43410 og-43410 og-43410 og-44610 og-43410 og-44010 og-46700 og-46700 og-47210 og-47210 og-44010 og-43410 og-44610

More information

ENTRANCES AND FRAMES INSTALLATION MANUAL

ENTRANCES AND FRAMES INSTALLATION MANUAL ENTRANCES AND FRAMES INSTALLATION MANUAL 11/18/13 Tubelite Inc. 0 of 31 11/18/13 Tubelite Inc. 1 of 31 INSTALLATION NOTES Allow 1/4" minimum shim and sealant space at sides and top of door frame. Door

More information

2.02. Specifications. General. Products. Execution. Offset Pivots P-694 Top and Bottom Pivots

2.02. Specifications. General. Products. Execution. Offset Pivots P-694 Top and Bottom Pivots 2.02 Standard Specifications General Entrances Description Furnish all necessary materials, labor and equipment for the complete installation of aluminum entrance doors, door frames and hardware as shown

More information

HMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES

HMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES HOLLOW METAL MANUAL NAAMM STANDARD HMMA 810-87 8d METAL DOORS & FRAMES NAAMM 2 87 HOLLOW METAL HOLLOW METAL DOORS FOURTH EDITION NAAMM 2 87 8d METAL DOORS & FRAMES A Division of NATIONAL ASSOCIATION OF

More information

190/350/500 Standard Entrances

190/350/500 Standard Entrances AUGUST, 2015 FEATURES 1 Features 190 narrow stile has 2-1/8" (54) vertical stile, 2-1/4" (57.2) top and 3-7/8" (98.4) bottom rail 350 medium stile has 3-1/2" (88.9) vertical stile, 3-1/2" (88.9) top and

More information

Sample Calculations...V-CR-12. Door and Window Typical Combinations... V-CR-12 Horizontal and Vertical Typical Combinations...

Sample Calculations...V-CR-12. Door and Window Typical Combinations... V-CR-12 Horizontal and Vertical Typical Combinations... SECTION DIRECTORY General Information Definitions...V-CR- Design Considerations...V-CR- Composite Configurations...V-CR-4 Design Considerations and Examples for Typical Window and Door Combinations...V-CR-5

More information

Thermal Block Entrance Installation Manual. Thermal Entrances. Installation Instructions. 05/21/14 Tubelite Inc. Page 0 of 20

Thermal Block Entrance Installation Manual. Thermal Entrances. Installation Instructions. 05/21/14 Tubelite Inc. Page 0 of 20 Thermal Entrances Installation Instructions 2010 05/21/14 Tubelite Inc. Page 0 of 20 TABLE OF CONTENTS INSTALLATION NOTES........................................ 2 PARTS LIST........................................

More information

Introduction...COMB-2 Design Considerations and Examples...COMB-3

Introduction...COMB-2 Design Considerations and Examples...COMB-3 SECTION DIRECTORY General Information Introduction...COMB-2 Design Considerations and Examples...COMB-3 Combination Assembly Recommendations and Limitations Composite Configurations...COMB-4 Typical Sealant

More information

CONFIGURATION 0 = fixed X = sliding. DOOR HEIGHT: 2100(h) Unit height 2090. DOOR HEIGHT: 2100(h) Unit height 2090

CONFIGURATION 0 = fixed X = sliding. DOOR HEIGHT: 2100(h) Unit height 2090. DOOR HEIGHT: 2100(h) Unit height 2090 ORIGIN PATIO DOOR SIDELIGHTS 0 = fixed X = sliding X Optional: Fly screen head and sill option. HEIGHT: Unit 10mm smaller 2210 2660 2960 3110 3560 4010 4460 Unit width as shown 300 600 900 PALACE SLIDING

More information

Fabrication Illustration Part No. Description Door Frame. P092 Mortised Butt Hinge P092D P092F (includes P2092 $ 48 $ 21 frame/door reinforcing)

Fabrication Illustration Part No. Description Door Frame. P092 Mortised Butt Hinge P092D P092F (includes P2092 $ 48 $ 21 frame/door reinforcing) Custom Blank Entrances - Applied Hardware & Preps - Tubelite Standard Hardware Butt Hinges Pivots C2 Page 1 P092 Mortised Butt Hinge P092D P092F (includes P2092 $ 48 $ 21 frame/door reinforcing) P795S

More information

SECTION 6. Glass Storefront Doors:

SECTION 6. Glass Storefront Doors: SECTION 6 Glass Storefront Doors: Table of Contents 3070 Storefront Door System Description & Dimensions 6070 Storefront Door System Description & Dimensions Door Leaf Detail Optional 10 Bottom Rail Detail

More information

REQUIREMENT 3. Usable Doors

REQUIREMENT 3. Usable Doors Chapter Three: REQUIREMENT 3 Usable Doors 3...covered multifamily dwellings with a building entrance on an accessible route shall be designed in such a manner that all the doors designed to allow passage

More information

CLEAR-DIVISIONS APERTO

CLEAR-DIVISIONS APERTO CLEAR-DIVISIONS Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS moveable glass wall system. The yellow highlighted areas in the

More information

A. Extent of hardware required is indicated on drawings and in schedules.

A. Extent of hardware required is indicated on drawings and in schedules. SECTION 087100 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division -1 Specification Sections, apply

More information

EZ Wire. Product Guide. Product Web Page

EZ Wire. Product Guide. Product Web Page EZ Wire Product Guide Product Web Page http://huskyrackandwire.com/products_ patented hook fastener Step 1: Align hooks and insert into slots Step 2: Hammer drive pin for a secure connection Value The

More information

TERRASPAN LIFT & SLIDE DOOR

TERRASPAN LIFT & SLIDE DOOR TERRASPAN LIFT & SLIDE DOOR BUILDING OPENING PREPARATION GUIDE READ THESE INSTRUCTIONS COMPLETELY BEFORE STARTING ANY INSTALLATION Kolbe & Kolbe Millwork, Co., Inc. 1323 S. 11th Ave. Wausau, Wisconsin

More information

CLEAR-DIVISIONS VARIOTEC TRIMLESS

CLEAR-DIVISIONS VARIOTEC TRIMLESS CLEAR-DIVISIONS VARIOTEC TRIMLESS Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS VARIOTEC TRIMLESS moveable glass wall system.

More information

CLEAR-DIVISIONS VARIOFOLD

CLEAR-DIVISIONS VARIOFOLD CLEAR-DIVISIONS VARIOFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS VARIOFOLD moveable The yellow highlighted areas in the

More information

CLEAR-DIVISIONS CENTERFOLD

CLEAR-DIVISIONS CENTERFOLD CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in

More information

GLASS WALL POCKET DOORS

GLASS WALL POCKET DOORS GLASS WALL POCKET DOORS KWIK-WALL... One Source for Wall Systems. KWIK-WALL s Pocket Doors for glass wall systems bring you the clear solution to your space division requirements. The beauty and elegance

More information

Black Sand Bronze We are a creative team based in New Zealand, we have been designing and making things for over 20 years, from the small scale of gold smithing to large civic projects, our passion is

More information

DE Frame with C Series Sidelight

DE Frame with C Series Sidelight TOOLS REQUIRED Tape measure 6' magnetic level 3' magnetic level Screw gun with clutch adjusted #2 phillips tip #3 phillips tip Screwdriver (used to adjust frame on will using oval slots) Pry Bar Powder

More information

BI-FOLDING GLASS WALL SYSTEM C.R. LAURENCE COMPANY

BI-FOLDING GLASS WALL SYSTEM C.R. LAURENCE COMPANY DOORS 08 3513 MONTEREY BI-FOLDING GLASS WALL SYSTEM Manufactured By U.S. ALUMINUM Cat. No. MO5580 Transform an Ordinary Space into the Extraordinary with the New C.R. LAURENCE COMPANY Worldwide Manufacturer

More information

Lori Greene, AHC/CDC, CCPR, FDAI

Lori Greene, AHC/CDC, CCPR, FDAI Lori Greene, AHC/CDC, CCPR, FDAI Manager, Codes & Resources 25+ years in the industry 20 years with Allegion and Ingersoll Rand Security Technologies Previous Positions Specification Team Leader New England

More information

SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word

More information

Architectural Information Page: Magnum Sliding Door Introduction

Architectural Information Page: Magnum Sliding Door Introduction Design Features Architectural Information Page: 72. 1 Introduction This sliding door has been designed to complement the Magnum window systems. The frame is 133mm wide and will snap to the 102mm wide Magnum

More information

HARDWARE LOCATIONS FOR HOLLOW METAL DOORS AND FRAMES

HARDWARE LOCATIONS FOR HOLLOW METAL DOORS AND FRAMES HOLLOW METAL MANUAL NAAMM STANDARD HMMA 831-11 8d NAAMM HMMA 831-11 METAL DOORS & FRAMES HARDWARE LOCATIONS FOR HOLLOW METAL DOORS AND FRAMES 8d NAAMM HMMA 831-11 METAL DOORS & FRAMES A Division of HOLLOW

More information

Wire Security Partitions & Cages Specification Guide

Wire Security Partitions & Cages Specification Guide Wire Security Partitions & Cages Specification Guide www.cisco-eagle.com/barriers Wire Partitions It doesn t have to be complicated... Cisco-Eagle publishes fully-illustrated, priced fast to order units

More information

LOCK BOLT ADJUSTMENT SCREW EXTERIOR SIDE DOOR FRAME WIDTH ROUGH FRAMED OPENING ROUGH OPENING. (Figure 1)

LOCK BOLT ADJUSTMENT SCREW EXTERIOR SIDE DOOR FRAME WIDTH ROUGH FRAMED OPENING ROUGH OPENING. (Figure 1) 160 SERIES OUT SWING ALUMINUM SINGLE OR PAIR DOOR WITH OR WITHOUT SIDELITE(S) INSTALLATION INSTRUCTIONS READ INSTRUCTIONS COMPLETELY BEFORE ATTEMPTING THE INSTALLATION These instructions are provided as

More information

Check rail (or meeting rail) One of the two adjacent horizontal sash members that come together when in the closed position.

Check rail (or meeting rail) One of the two adjacent horizontal sash members that come together when in the closed position. GLOSSARY OF TERMS Airspace The space between adjacent layers in a multi-layer glazing system. Awning Window A single-sash window that s hinged at the top of the sash and uses a handle crank that allows

More information

Window Replacement Information Sheet (Use this form only when windows are replaced with same size and type and no plans are provided)

Window Replacement Information Sheet (Use this form only when windows are replaced with same size and type and no plans are provided) Window Replacement Information Sheet (Use this form only when windows are replaced with same size and type and no plans are provided) WINDOW SIZE OPENING TYPE ROOM U-VALUE OF (N) WINDOW (.32 maximum) Existing

More information

The replacement or modification of existing windows shall comply with the following requirements:

The replacement or modification of existing windows shall comply with the following requirements: City of La Habra Heights Building Division 1245 N. Hacienda Road La Habra Heights, CA 90631 Office: (562) 694-6302 ext. 228 Fax: (562) 690-5010 WINDOW REPLACEMENT 2010 CALIFORNIA RESIDENTIAL CODE (CRC)

More information

Fire-rated Aluminum Doors

Fire-rated Aluminum Doors Fire-rated Aluminum Doors Langebjergvænget 13 ALUFLAM has pioneered the innovative solution to what was long considered an impossible dream (and a barrier to truly beautiful commercial architectural design),

More information

Sliding Patio Door Milgard Aluminum Door

Sliding Patio Door Milgard Aluminum Door Sliding Door Sliding Patio Door Milgard Aluminum Door The Series Sliding Door has been specially designed to meet the building practices and climatic conditions of the West Coast market. The door features

More information

CDW Systems Ltd Contemporary Doors & Windows

CDW Systems Ltd Contemporary Doors & Windows CDW Systems Ltd Contemporary Doors & Windows The comprehensive product overview A complete specification guide to CDW Systems range of Aluminium windows, doors and curtain walling for commercial and residential

More information

Hinge, Blocker, and Tab Adjustment Guide

Hinge, Blocker, and Tab Adjustment Guide Hinge, Blocker, and Guide for Andersen A-Series Hinged Outswing; 400 Series Frenchwood Hinged Outswing Patio Doors and 400 Series Frenchwood Hinged Outswing Patio Doors with Stormwatch Protection Hinge,

More information

Priority 2 Access to Goods & Services

Priority 2 Access to Goods & Services Based on the 2010 ADA Standards for Accessible Design Project Building Location Date Surveyors Contact Information The layout of the building should allow people with disabilities to obtain goods and services

More information

4x4 Pocket Door Slide

4x4 Pocket Door Slide KV 8090 Series TM 4x4 Pocket Door Slide Specifications: 75-pound maximum per door. Designed to mount to side of case for vertical pocket doors. Maximum door dimension of 26 x 72. Not recommended for square

More information

ROUGH OPENING DIMENSION OPP. OPP. NET DOOR WIDTH NET DOOR WIDTH 1/8" OVERALL NET DOOR WIDTH DOOR OPENING ROUGH OPENING DIMENSION

ROUGH OPENING DIMENSION OPP. OPP. NET DOOR WIDTH NET DOOR WIDTH 1/8 OVERALL NET DOOR WIDTH DOOR OPENING ROUGH OPENING DIMENSION 1.5 2.1 2.3 1.1 OVERALL 1.5 2.8 2.8 2.2 2.3 2.1 3/8" NET DOOR HEIGHT 2.4 1.1 2.2 OVERALL 2.3 2.1 1.7 1.8 1.3 1.8 1.6 1.2 1.4 1.6 1.2 1.4 1.6 1.6 1.2 1.4 1.6 1 3/ 2.10 2.1 2.3 2.5 2.1 3/8" NET DOOR HEIGHT

More information

Beauty-Line Windows (1957 to 1979)

Beauty-Line Windows (1957 to 1979) Beauty-Line Windows (1957 to 1979) Parts Catalog Main Menu Section TOC Search What s in This Section Standard Windows................................................ Page 3 Parts Illustration...........................................................

More information

FINISHES DESIGNATIONS... 2 PAINTED FINISHES...3, 4 STANDARD HARDWARE FINISH OFFERINGS...5, 6

FINISHES DESIGNATIONS... 2 PAINTED FINISHES...3, 4 STANDARD HARDWARE FINISH OFFERINGS...5, 6 FEBRUARY, 2014 FINISHES INDEX 1 FINISHES DESIGNATIONS... 2 PAINTED FINISHES...3, 4 STANDARD HARDWARE FINISH OFFERINGS...5, 6 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE,

More information

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER: Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER: SECTIONS 1, 2, 3, AND 4 MUST BE COMPLETED BY APPLICANT BEFORE INSPECTION

More information

BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401

BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401 BASIC FIRE DOOR REQUIREMENTS SHEET NO. 401 Fire door openings are classified by their locations in the building. The location determines the length of exposure protection required, based on the potential

More information

INSTALLATION INSTRUCTIONS CLAD INSWING BI-FOLD DOOR AND WINDOW SYSTEM WITH U-CHANNEL

INSTALLATION INSTRUCTIONS CLAD INSWING BI-FOLD DOOR AND WINDOW SYSTEM WITH U-CHANNEL INSTALLATION INSTRUCTIONS CLAD INSWING BI-FOLD DOOR AND WINDOW SYSTEM WITH U-CHANNEL Please read these instructions in their entirety prior to beginning the installation process. Sierra Pacific Windows

More information

WINDOW FRAMES FIRE WINDOWS FIRE RATED PRODUCTS

WINDOW FRAMES FIRE WINDOWS FIRE RATED PRODUCTS FIRE WINDOWS FIRE RATED PRODUCTS WINDOW FRAMES s FIRE RATED WINDOW FRAMES: The fire window (borrowed light) frames covered in this section, have been tested in accordance with NFPA 257, and UL9 and listed

More information

DOOR CONTROL C.R. LAURENCE COMPANY

DOOR CONTROL C.R. LAURENCE COMPANY DOOR HARDWARE 08 7100 DOOR CONTROL HARDWARE AND ACCESSORIES C.R. LAURENCE COMPANY Worldwide Manufacturer and Supplier Glazing, Architectural, Railing, Screen, Construction, Industrial, and Automotive Supplies

More information

Automatic Door Selection Guide

Automatic Door Selection Guide Automatic Door Selection Guide AAADM 1300 Sumner Avenue Cleveland, OH 44115 P: 216-241-7333 F: 216-241-0105 aaadm@aaadm.com Automatic Door Selection Guide General: The members of AAADM manufacture an assortment

More information

DOORS HOLLOW METAL MANUAL NAAMM STANDARD NAAMM HMMA 810-09 METAL DOORS & FRAMES METAL. A Division of

DOORS HOLLOW METAL MANUAL NAAMM STANDARD NAAMM HMMA 810-09 METAL DOORS & FRAMES METAL. A Division of HOLLOW METAL MANUAL NAAMM STANDARD HMMA 810-09 8d NAAMM HMMA 810-09 METAL DOORS & FRAMES HOLLOW METAL DOORS 8d NAAMM HMMA 810-09 METAL DOORS & FRAMES A Division of HOLLOW METAL MANUFACTURERS A S S O C

More information

MINNESOTA DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division STATEMENT OF POLICY. State Fire Marshal

MINNESOTA DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division STATEMENT OF POLICY. State Fire Marshal MINNESOTA DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division STATEMENT OF POLICY Policy #: Subject of Policy: INS-04 (2007) Escape Windows Revised and Approved By: Title: Jerry Rosendahl State Fire

More information

ALDUS Composite Bi-Fold Doors

ALDUS Composite Bi-Fold Doors ALDUS Composite Bi-Fold Doors ALDUS Composite Bi-Fold Doors Rationel s range of ALDUS Bi-Folding doors offers you peace of mind. A system that has been installed internationally for over 25 years, providing

More information

Walking and Working Surface Checklist:

Walking and Working Surface Checklist: Walking and Working Surfaces Purpose: This information is presented to improve the level of safety in our operations, and to inform you that we will comply with the OSHA Standard 29 CFR 1910.23. Responsibility:

More information

Size & Range. for windows & doors. Company

Size & Range. for windows & doors. Company Size & Range for windows & doors A Company B General information windows and doors Sizes This catalogue contains all Airlite s standard sizes for windows and doors. These are the ones that we make every

More information

Number of Sides Required to Have a Handrail

Number of Sides Required to Have a Handrail Excerpt from 2012 B.C. Building Code HANDRAILS & GUARDS 9.8.7. Handrails 9.8.7.1. Required Handrails 1) Except as provided in Sentences (2) to (4), handrails shall be installed on stairs and ramps in accordance

More information

Architectural Door Specifications Flush Doors 20 minute rating

Architectural Door Specifications Flush Doors 20 minute rating Section FRD Page 1 Architectural Door Specifications Flush Doors 20 minute rating Materials: Stiles: Laminated Timberstrand 38mm X 43mm Rails: Timberstrand 38 mm x 43 mm, extending the full width of the

More information

DECKS/PORCHES. 2. Final inspection required 2. Framing inspection required 3. Insulation inspection if requested 4. Final inspection required

DECKS/PORCHES. 2. Final inspection required 2. Framing inspection required 3. Insulation inspection if requested 4. Final inspection required DECKS/PORCHES Building Department 507-437-9950 Fax: 507-437-7101 City of Austin 500 4 th Ave NE Austin, MN 55912 PERMITS: A building permit is required for construction of deck or porch that is more than

More information

Flexivent Windows (1952 to 1979)

Flexivent Windows (1952 to 1979) Flexivent Windows (1952 to 1979) Parts Catalog Main Menu Section TOC Search What s in This Section Standard Windows................................................ Page 3 Parts Illustration...........................................................

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

Access Control Systems Compliance with the DDA

Access Control Systems Compliance with the DDA Technical Bulletin Product: Topic: Access Control Systems Compliance with the DDA Bulletin Number: B 020 Prepared by: Hugh Lawson File: I:\Technical Bulletins\Technical Bulletin B020 - Access Control Systems

More information

ISSUE 2. Installation Guide

ISSUE 2. Installation Guide ISSUE 2 Installation Guide Here at Slide and Fold, we LOVE our Bi-Fold Plus range of folding-sliding doors. We want to ensure that your customers love them too. So we have created a new, detailed installation

More information

Vestibule Case Study. Vestibule Requirement Intent [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, 90.1-2001, 90.1-2004]

Vestibule Case Study. Vestibule Requirement Intent [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, 90.1-2001, 90.1-2004] Vestibule Case Study [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, 90.1-2001, 90.1-2004] Vestibule Requirement Intent Page 1 of 14 The primary intent behind the requirement for a vestibule is to reduce infiltration

More information

AC-3200 ALUMINUM PLATE SYSTEM (DRY JOINT)

AC-3200 ALUMINUM PLATE SYSTEM (DRY JOINT) ALUMINUM PLATE SYSTEM (DRY JOINT) C D E G P J L A H M B Q F A B C D E F G H J K L M N P Q R HORIZONTAL JOINT DETAIL VERTICAL JOINT DETAIL COPING DETAIL (1) COPING DETAIL (2) COPING DETAIL (3) OUTSIDE CORNER

More information

Class A Office Buildings Commercial Facilities College and University Campuses K-12 Buildings Healthcare Facilities Government & Military Structures

Class A Office Buildings Commercial Facilities College and University Campuses K-12 Buildings Healthcare Facilities Government & Military Structures Bringing New Light to Interior Architecture Expansive New Light Frameworks brings new light to interior architecture with doors, frames and windows that pair custom and standard glazing options with an

More information

I N T E R N A T I O N A L R E S I D E N T I A L CO D E

I N T E R N A T I O N A L R E S I D E N T I A L CO D E Visual Interpretation Of The I N T E R N A T I O N A L R E S I D E N T I A L CO D E 2003 STAIR BUILDING CODE Portions of this document reproduce sections from the 2003 International Residential Code, International

More information

Aluminium systems profile selection

Aluminium systems profile selection Aluminium systems profile selection The purpose of this document is to summarise the way that aluminium profile selection should be made, based on the strength requirements for each application. Curtain

More information

I N T E R N A T I O N A L R E S I D E N T I A L CO D E

I N T E R N A T I O N A L R E S I D E N T I A L CO D E Visual Interpretation Of The I N T E R N A T I O N A L R E S I D E N T I A L CO D E 2006 STAIR BUILDING CODE Portions of this document reproduce sections from the 2006 International Residential Code, International

More information

http://www.iccsafe.org/

http://www.iccsafe.org/ Sections R311 and R312 from the 2006 International Residential Code These sections of Chapter 3 of the 2006 International Residential Code for One and Two Family Dwellings (R311 and R312) including the

More information

Base Cabinet with Self-storing Folding Doors and Floor

Base Cabinet with Self-storing Folding Doors and Floor Usable Kitchens When designing a kitchen for use by persons with mobility impairments, especially those who use wheelchairs, careful layout of the kitchen is crucial to maintaining accessibility. People

More information

5621, 5621F Sliding Doors

5621, 5621F Sliding Doors 5621, 5621F Sliding Doors 5621, 5621F SLIDING DRS - 2, 3, 4 - panel - Special size doors available* - - fixed panel - Keyed lock available (Schlage -compatible) 2-panel 2-panel 2-PANEL - Min 5 0 6 8 Max

More information

TECNA Partition wall 10 TECNA is universal partition wall. Unique in richness and configuration possibilities, it can be enhanced with natural wood pa

TECNA Partition wall 10 TECNA is universal partition wall. Unique in richness and configuration possibilities, it can be enhanced with natural wood pa tecna TECNA Partition wall 10 TECNA is universal partition wall. Unique in richness and configuration possibilities, it can be enhanced with natural wood panels and accessory components. Intrinsically

More information

Doors and Windows. Construction Methods and Materials. Doors and Windows

Doors and Windows. Construction Methods and Materials. Doors and Windows Doors Door provide: Privacy Safety/Security Beauty Ventilation (screen and Dutch doors) Light (with glazing in door or sidelights) Swinging Door A door that moves via a hinged point. Classified as either

More information

How to Measure for Exterior Shutters

How to Measure for Exterior Shutters Tools you may need: Measuring Tape Pencil Paper Ladder How to Measure for Exterior Shutters Measuring your windows properly is an important step to ensure your installation goes both smoothly and that

More information

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS 1009.1 Stairway width. The width of stairways shall be determined as specified in Section 1005.1, but such width shall not be less than 44

More information

TRIANGLE BRASS MANUFACTURING COMPANY, INC. Fine Builders Hardware

TRIANGLE BRASS MANUFACTURING COMPANY, INC. Fine Builders Hardware TRIANGLE BRASS MANUFACTURING COMPANY, INC. Fine Builders Hardware 3528 Emery Street, P.O. Box 23277 Los Angeles, California 90023, U.S.A. Telephone (323) 262-4191 Fax (323) 264-7214 or (800) 637-TRIM (8746)

More information

Installation instructions for Pella Storm Door on a Clad Frame Pella or Architect Series Entry Door

Installation instructions for Pella Storm Door on a Clad Frame Pella or Architect Series Entry Door Pella Storm Door Installation Instructions lad Frame pplication Traditional Installation lternative Installation instructions for Pella Storm Door on a lad Frame Pella or rchitect Series Entry Door dditional

More information

glass entrance systems

glass entrance systems glass entrance systems Hardware: Center-Hung Pivots Top-Pivot Walking Beam Provides top pivot for center-pivoted, all-glass doors. Bottom-Pivot-Floor or Threshold Provides an adjustable bottom pivot for

More information

Basic Fire Door Requirements

Basic Fire Door Requirements TECHNICAL DATA SERIES S D I 118-01 Basic Fire Door Requirements 2001 Steel Door Institute STEEL DOOR INSTITUTE 30200 DETROIT ROAD - CLEVELAND, OHIO 44145 Technical Data Series SDI 118-2001 Basic Fire Door

More information

PUBLIC RESTROOMS, DESIGN INTENT

PUBLIC RESTROOMS, DESIGN INTENT PUBLIC RESTROOMS, DESIGN INTENT 1.01 STRUCTURAL A. Where feasible, metal stud partitions will be constructed on a 6 high concrete curb. 1.02 MECHANICAL A. Restrooms will have a minimum of 15 air changes

More information

An ASSA ABLOY Group brand. 2700 Series. Architectural Door Closers

An ASSA ABLOY Group brand. 2700 Series. Architectural Door Closers An ASSA ABLOY Group brand 2700 Series Architectural Door Closers Page Revised Electronically 11/12 2700 series door closers introduction Yale 2700 series architectural door closers are ideal for commercial

More information

TRANSOM AND SIDELIGHT FRAMES:

TRANSOM AND SIDELIGHT FRAMES: TRANSOM & SIDELIGHTS FIRE RATED PRODUCTS TRANSOM AND SIDELIGHT FRAMES: s Sidelight Frame Sidelight Frame Transom/Sidelight Frame Transom Frames with Bar FIRE RATED TRANSOM AND SIDELIGHTS: The transom and

More information

ACCESSIBILITY DETAILS FOR DOORS, MANEUVERING SPACES & ROUTES

ACCESSIBILITY DETAILS FOR DOORS, MANEUVERING SPACES & ROUTES INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LABC Sec. 11B-304,305,404 Effective: 01/01/2014 DOCUMENT NO.: Revised: 07/01/2015 Previously Issued As: P/BC 2011-086 ACCESSIBILITY DETAILS

More information

glass & Glazing Products

glass & Glazing Products glass & Glazing Products WallMaker Create an unlimited variety of bright, beautiful and secure interior environments with the easy-to-install Stylmark WallMaker glass wall system. This versatile system

More information

LCN 2030 SERIES FEATURES CONCEALED (IN 1 3/4 HEADER) MOUNTING. The concealed 2030 Series. PACER is a heavy duty closer. designed to fit in a narrow,

LCN 2030 SERIES FEATURES CONCEALED (IN 1 3/4 HEADER) MOUNTING. The concealed 2030 Series. PACER is a heavy duty closer. designed to fit in a narrow, CONCEALED (IN 1 3/4 HEADER) MOUNTING The concealed 2030 Series PACER is a heavy duty closer designed to fit in a narrow, minimum 1 3/4 aluminum transom. The single lever arm and roller assembly provide

More information

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11 K. D. FRAME ASSEMBLY FOR MASONRY WALLS...........................Ins 2 FRAME INSTALLATION DETAILS FOR MASONRY WALLS......................Ins 3 INSTALLING EXISTING MASONRY WALL ANCHORS IN FRAME..................Ins

More information

LLOYD INDUSTRIES INC. DAMPER INSTALLATION INSTRUCTIONS

LLOYD INDUSTRIES INC.  DAMPER INSTALLATION INSTRUCTIONS DAMPER Installation and Maintenance Instructions 1-1/2 Hour Rated, UL Classified model 75 fire dampers For use in fire barriers with ratings of less than 3 hours INSPECTION 1. Inspect for shipping damage.

More information

InsulView Window Installation Instructions

InsulView Window Installation Instructions InsulView Window Installation Instructions 1. The entire building is normally sheeted with the 2" 2 ½ OR 3 wall panel and the windows installed at a later time. A window retrofit of an existing building

More information

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: CORAL ARCHITECTURAL PRODUCTS

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: CORAL ARCHITECTURAL PRODUCTS Architectural Testing ASTM E 1886 and ASTM E 1996 TEST REPORT Rendered to: CORAL ARCHITECTURAL PRODUCTS SERIES/MODEL: PW 256 with Door Openings PRODUCT TYPE: Aluminum Impact Resistant Curtain Wall System

More information

Drum Dispensing Stations

Drum Dispensing Stations Drum Dispensing Stations O Safely Dispense from 55 Gallon Drums over a Spill Compliant Sump. 1-2-and 4 drum models available Drums are securely held on racks by galvanized positioners Sump and frame constructed

More information

WINDOW PANNING AND TRIMS

WINDOW PANNING AND TRIMS OCTOBER, 2010 PANNING AND TRIMS GENERAL INFORMATION 1 EXTERIOR PANNING Panning is primarily used to cover the perimeters of existing building openings prior to the installation of replacement windows.

More information

Stadium Chairs. Table of Contents. Products for Construction and Expansion Joints. Products for ADA Compliance

Stadium Chairs. Table of Contents. Products for Construction and Expansion Joints. Products for ADA Compliance Table of Contents Products for Construction and Expansion Joints Products for ADA Compliance Floor and Riser Design Requirements/ Guidelines Chair Sizing Chart Row Spacing Chart Sightline Formula Profile

More information

Content MCELROY. TABLE of CONTENTS

Content MCELROY. TABLE of CONTENTS Content MCELROY TABLE of CONTENTS Max-Rib Typical framing and Stitch Fastener Patterns 1 MESA Typical Framing and Stitch Fastener Patterns 2 Base Trim Detail 3 Outside Corner Detail 4 Inside Corner Detail

More information

Installation Instructions

Installation Instructions Installation Instructions READ BEFORE INSTALLING UNIT For Low Profile Window Air Conditioner INSTALLATION WARNINGS AND CAUTION Carefully read the installation manual before beginning. Follow each step

More information

Wood Sound Retardant Door Hardware Information Bulletin

Wood Sound Retardant Door Hardware Information Bulletin overly overly 574 West Otterman Street Greensburg, PA 15601 Toll Free: (800) 979-7300 Local: (724) 834-7300 Fax: (724) 830-2871 Email: overly@overly.com DOOR COMPANY Wood Sound Retardant Door Hardware

More information

Where can you use door gear?

Where can you use door gear? 04.12.2015 1 We will do this by looking at 3 key areas - What is sliding, sliding folding and sliding stacking door gear? We will explain the differences between different types of door gear and look in

More information

Table of Contents. IV. Interior Doors. 1. Product Training 2. Bilco Quote/Order Checklist

Table of Contents. IV. Interior Doors. 1. Product Training 2. Bilco Quote/Order Checklist Table of Contents IV. Interior Doors 1. Product Training 2. Bilco Quote/Order Checklist Interior Doors (non-drainage units) 1. Bilco T, TD, K, and KD Type doors A. T - single leaf aluminum construction

More information

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B8049.01-401-18. Rendered to: AMERICAN PRODUCTS, INC Tampa, Florida

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B8049.01-401-18. Rendered to: AMERICAN PRODUCTS, INC Tampa, Florida Architectural Testing MIAMI-DADE COUNTY PERFORMANCE TEST REPORT Report No.: B8049.01-401-18 Rendered to: AMERICAN PRODUCTS, INC Tampa, Florida PRODUCT TYPE: Aluminum Storefront with Double Doors SERIES/MODEL:

More information

Measuring Guide Roller Blind

Measuring Guide Roller Blind Face Fix (Outside Mount) This measurement will fit on the outside of your window frame, on the face of your architrave. It is recommended that you under roll to minimise light and increase privacy. Please

More information

Guide Specification Section Interior Sliding Glass Doors

Guide Specification Section Interior Sliding Glass Doors Guide Specification Section 08 32 13 Interior Sliding Glass Doors SECTION 08 32 13 The Sliding Door Company s namesake product combines operable sliding glass doors with stationary glazed panels to create

More information