3. OUTDOOR UNITS DTV_V2E011E_21--CHAPTER

Size: px
Start display at page:

Download "3. OUTDOOR UNITS DTV_V2E011E_21--CHAPTER03 2013.04.01"

Transcription

1 3. DTV_V2E011E_21--CHAPTER

2 CONTENTS SPECIFICATIONS SPACE SAVING COMBINATION ENERGY EFFICIENCY COMBINATION DIMENSIONS SINGLE UNIT COMBINATION INSTALLATION SPACE WHEN INSTALL NEAR BY LIMITED HEIGHT WALL WHEN INSTALL NEAR BY UNLIMITED HEIGHT WALL WHEN THERE IS AN OBSTRUCTION ABOVE THE PRODUCT CONCENTRATED INSTALLATION EXAMPLE INSTALLATION ON EACH FLOOR REFRIGERANT CIRCUIT WIRING DIAGRAM OPERATION RANGE NOISE LEVEL CURVE ELECTRIC CHARACTERISTICS SAFETY DEVICES LOCALLY PROCURED PARTS AIR DISCHARGE DUCT SNOW HOOD PRESSURE GAUGE CENTRAL DRAIN PAN

3 111SPECIFICATIONS 11111SPACE SAVING COMBINATION Nominal system capacity HP Model name AJ A90LALH Power source 3 Phase ~ 400 V, 50Hz Available voltage range 342 to 456V Capacity Cooling kw Heating Input power Cooling kw Heating EER Cooling W / W COP Heating Type x Quantity Propeller fan x 1 Airflow rate High m 3 / h 11,100 11,100 11,100 (l / s) (3,084) (3,084) (3,084) Fan External static pressure (Max) Pa Motor Type x Quantity DC motor 1 Output W Sound pressure Cooling db(a) level Heating Length 1,760 1,760 1,760 Fin pitch Rows x Stages 3 x 60 Heat exchanger Face area m Pipe type (Material) Grooved H-pin (Copper) Fin Type (Material) Corrugate (Aluminium) Surface treatment Corrosion resistance (Blue fin) Rotary(inv) x 1 Type x Quantity Rotary(inv) x 1 Rotary(inv) x 1 Scroll x 1 Compressor Motor output kw Crankcase heater W Refrigerant Type R410A Charge kg Refrigerant oil Type PVE Enclosure Material Painted galvanized steel Colour Beige (10YR 7.5/1.0NN) Dimensions Net 1, , , (H x W x D) Gross 1,811 1, ,811 1, ,811 1, Weight Net kg Gross Pipe Liquid diameter Gas Connection pipe Method Liquid Brazing Gas Brazing Max. length 150 m Max. height difference 50 / 40 (Outdoor unit : Upper / Lower) Operation temper- Cooling -15 to 46 *1 CDB ature range Heating -20 to 21 Defrost method Reversed cycle Compressor capacity control (Steps / Range) 71 Steps / % 127 Steps / % Connectable indoor units Number Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. *1 : In case of use multiple outdoor units : -5 to 46 C - (03-01) -

4 Nominal system capacity HP Model name AJ 144LALH Power source 3 Phase ~ 400 V, 50Hz Available voltage range 342 to 456V Capacity Cooling kw Heating Input power Cooling kw Heating EER Cooling W / W COP Heating Type x Quantity Propeller fan x 1 Airflow rate High m 3 / h 13,000 13,000 (l / s) (3611) (3611) Fan External static pressure (Max) Pa Motor Type x Quantity DC motor 1 Output W Sound pressure Cooling db(a) level Heating Length 2,070 2,070 Fin pitch Rows x Stages 3 x 60 Heat exchanger Face area m Pipe type (Material) Grooved H-pin (Copper) Fin Type (Material) Corrugate (Aluminium) Surface treatment Corrosion resistance (Blue fin) Rotary(inv) x 1 Rotary(inv) x 1 Type x Quantity Scroll x 1 Scroll x 1 Compressor Motor output kw Crankcase heater W Refrigerant Type R410A Charge kg Refrigerant oil Type PVE Enclosure Material Painted galvanized steel Colour Beige (10YR 7.5/1.0NN) Dimensions Net 1,690 x 1,240 x 765 1,690 x 1,240 x 765 (H x W x D) Gross 1,811 1, ,811 1, Weight Net kg Gross Pipe Liquid diameter Gas Connection pipe Method Liquid Brazing Gas Brazing Max. length 150 m Max. height difference 50 / 40 (Outdoor unit : Upper / Lower) Operation temper- Cooling -15 to 46 *1 CDB ature range Heating -20 to 21 Defrost method Reversed cycle Compressor capacity control (Steps / Range) 127 Steps / % Connectable indoor units Number Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. *1 : In case of use multiple outdoor units : -5 to 46 C - (03-02) -

5 Nominal system capacity HP Set model name AJ 162LALH AJ 1LALH AJ 198LALH AJ 216LALH Model name (combination) AJ A90LALH AJ A90LALH Power source 3 Phase ~ 400 V, 50Hz Available voltage range 342 to 456 V Capacity Cooling kw Heating Input power Cooling kw Heating EER Cooling W / W COP Heating Type x Quantity Propeller fan x 2 Airflow rate High m 3 / h 11, , , ,100 2 (l / s) (3,084 2) (3,084 2) (3,084 2) (3,084 2) Fan External static pressure (Max) Pa Motor Type x Quantity DC motor 2 Output W 700 x x x x 2 Sound pressure level Cooling db(a) Heating Length 1, , , ,760 2 Fin pitch Rows x Stages 3 x 60 Heat exchanger Face area m Pipe type (Material) Grooved H-pin (Copper) Fin Type (Material) Corrugate (Aluminium) Surface treatment Corrosion resistance (Blue fin) Type x Quantity Rotary(inv) x 2 Rotary(inv) x 2 Rotary(inv) x 2 Rotary(inv) x 2 Scroll x 1 Scroll x 1 Scroll x 2 Compressor Motor output kw Crankcase heater W Refrigerant Type R410A Charge kg Refrigerant oil Type PVE Enclosure Material Painted galvanized steel Colour Beige (10YR 7.5/1.0NN) Dimensions (H x W x D) Net Gross (1, ) 2 (1,811 1, ) 2 (1, ) 2 (1,811 1, ) 2 (1, ) 2 (1,811 1, ) 2 (1, ) 2 (1,811 1, ) 2 Net Weight kg Gross Pipe Liquid diameter Gas Liquid Brazing Connection pipe Method Gas Brazing Max. length 150 m Max. height difference 50 / 40 (Outdoor unit : Upper / Lower) Operation temper- Cooling -5 to 46 CDB ature range Heating -20 to 21 Defrost method Reversed cycle Connectable indoor units Number Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. - (03-03) -

6 Nominal system capacity HP Set model name AJ 234LALH AJ 252LALH AJ 270LALH AJ 288LALH Model name (combination) AJ 144LALH AJ 144LALH AJ 144LALH AJ 144LALH Power source 3 Phase ~ 400 V, 50Hz Available voltage range 342 to 456 V Capacity Cooling kw Heating Input power Cooling kw Heating EER Cooling W / W COP Heating Type x Quantity Propeller fan x 2 Airflow rate High m 3 / h 13, ,100 13, ,100 13, ,000 2 (l / s) (3, ,084) (3, ,084) (3,611 2) (3,611 2) Fan External static pressure (Max) Pa Motor Type x Quantity DC motor 2 Output W 700 x x x x 2 Sound pressure Cooling db(a) level Heating Length 2, ,760 2, ,760 2, ,070 2 Fin pitch Rows x Stages (3 x 60) x 2 Heat exchanger Face area m Pipe type (Material) Grooved H-pin (Copper) Fin Type (Material) Corrugate (Aluminium) Surface treatment Corrosion resistance (Blue fin) Rotary(inv) x 2 Rotary(inv) x 2 Rotary(inv) x 2 Rotary(inv) x 2 Type x Quantity Scroll x 2 Scroll x 2 Scroll x 2 Scroll x 2 Compressor Motor output kw Crankcase heater W Refrigerant Type R410A Charge kg Refrigerant oil Type PVE Enclosure Material Painted galvanized steel Colour Beige (10YR 7.5/1.0NN) 1,690 1, ,690 1, (1,690 1, ) (1,690 1, ) Net Dimensions 1, , (H x W x D) 1,811 1, ,811 1, (1,811 1, ) (1,811 1, ) Gross 1,811 1, ,811 1, Weight Net kg Gross Pipe Liquid diameter Gas Connection pipe Method Liquid Brazing Gas Brazing Max. length 150 m Max. height difference 50 / 40 (Outdoor unit : Upper / Lower) Operation temper- Cooling -5 to 46 CDB ature range Heating -20 to 21 Defrost method Reversed cycle Connectable indoor units Number Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. - (03-04) -

7 Nominal system capacity HP Set model name AJ 306LALH AJ 324LALH AJ 342LALH AJ 360LALH Model name (combination) AJ A90LALH AJ 144LALH Power source 3 Phase ~ 400 V, 50Hz Available voltage range 342 to 456 V Capacity Cooling kw Heating Input power Cooling kw Heating EER Cooling W / W COP Heating Type x Quantity Propeller fan x 3 Dimensions (H x W x D) Airflow rate High m 3 / h (l / s) 11,100 3 (3,084 3) 11,100 3 (3,084 3) Net (1, ) 3 (1, ) 3 Gross (1,811 1, ) 3 (1,811 1, ) 3 13, , , ,100 2 (3, ,084 2) (3, ,084 2) Fan External static pressure (Max) Pa Motor Type x Quantity DC motor 3 Output W 700 x x x x 3 Sound pressure Cooling db(a) level Heating Length 1, , , , , ,760 2 Fin pitch Rows x Stages (3 x 60) x 3 Heat exchanger Face area m Pipe type (Material) Grooved H-pin (Copper) Fin Type (Material) Corrugate (Aluminium) Surface treatment Corrosion resistance (Blue fin) Rotary(inv) x 3 Rotary(inv) x 3 Rotary(inv) x 3 Rotary(inv) x 3 Type x Quantity Scroll x 2 Scroll x 3 Scroll x 3 Scroll x 3 Compressor Motor output kw Crankcase heater W Refrigerant Type R410A Charge kg Refrigerant oil Type PVE Enclosure Material Painted galvanized steel Colour Beige (10YR 7.5/1.0NN) (1,690 1, ) (1,690 1, ) (1, ) 2 (1, ) 2 (1,811 1, ) (1,811 1, ) (1,811 1, ) 2 (1,811 1, ) Weight Net kg Gross Pipe Liquid diameter Gas Connection pipe Method Liquid Brazing Gas Brazing Max. length 150 m Max. height difference 50 / 40 (Outdoor unit : Upper / Lower) Operation temper- Cooling -5 to 46 CDB ature range Heating -20 to 21 Defrost method Reversed cycle Connectable indoor units Number Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. - (03-05) -

8 Nominal system capacity HP Set model name AJ 378LALH AJ 396LALH AJ 414LALH AJ 432LALH Model name (combination) AJ 144LALH AJ 144LALH AJ 144LALH AJ 144LALH AJ 144LALH AJ 144LALH AJ 144LALH AJ 144LALH Power source 3 Phase ~ 400 V, 50Hz Available voltage range 342 to 456 V Capacity Cooling kw Heating Input power Cooling kw Heating EER Cooling W / W COP Heating Type x Quantity Propeller fan x 3 Airflow rate High m 3 / h (l / s) 13, ,100 (3, ,084) 13, ,100 (3, ,084) 13,000 3 (3,611 3) 13,000 3 (3,611 3) Fan External static pressure (Max) Pa Motor Type x Quantity DC motor 3 Output W 700 x x x x 3 Sound pressure Cooling db(a) level Heating Length 2, ,760 2, ,760 2, ,070 3 Fin pitch Rows x Stages (3 x 60) x 3 Heat exchanger Face area m Pipe type (Material) Grooved H-pin (Copper) Fin Type (Material) Corrugate (Aluminium) Surface treatment Corrosion resistance (Blue fin) Rotary(inv) x 3 Rotary(inv) x 3 Rotary(inv) x 3 Rotary(inv) x 3 Type x Quantity Scroll x 3 Scroll x 3 Scroll x 3 Scroll x 3 Compressor Motor output kw Crankcase heater W Refrigerant Type R410A Charge kg Refrigerant oil Type PVE Enclosure Material Painted galvanized steel Colour Beige (10YR 7.5/1.0NN) Dimensions (H x W x D) Net Gross (1,690 1, ) 2 (1, ) (1,811 1, ) 2 (1,811 1, ) (1,690 1, ) 2 (1, ) (1,811 1, ) 2 (1,811 1, ) (1,690 1, ) 3 (1,690 1, ) 3 (1,811 1, ) 3 (1,811 1, ) 3 Weight Net kg Gross Pipe Liquid diameter Gas Connection pipe Method Liquid Brazing Gas Brazing Max. length 150 m Max. height difference 50 / 40 (Outdoor unit : Upper / Lower) Operation temper- Cooling -5 to 46 CDB ature range Heating -20 to 21 Defrost method Reversed cycle Connectable indoor units Number Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. - (03-06) -

9 11111ENERGY EFFICIENCY COMBINATION Nominal system capacity HP Set model name AJ 144LALHH AJ 198LALHH Model name (combination) Power source 3 Phase ~ 400 V, 50Hz Available voltage range 342 to 456V Capacity Cooling kw Heating Input power Cooling kw Heating EER Cooling W / W COP Heating Type x Quantity Propeller fan x 2 Airflow rate High m 3 / h 11, , ,100 (l / s) (3,084 2) (3, ,084) Fan External static pressure (Max) Pa Motor Type x Quantity DC motor 2 Output W 700 x x 2 Sound pressure Cooling db(a) level Heating Length 1, , ,760 Fin pitch Rows x Stages (3 x 60) x 2 Heat exchanger Face area m Pipe type (Material) Grooved H-pin (Copper) Fin Type (Material) Corrugate (Aluminium) Surface treatment Corrosion resistance (Blue fin) Rotary(inv) x 2 Type x Quantity Rotary(inv) x 2 Scroll x 1 Compressor Motor output kw Crankcase heater W Refrigerant Type R410A Charge kg Refrigerant oil Type PVE Enclosure Material Painted galvanized steel Colour Beige (10YR 7.5/1.0NN) (1,690 1, ) Net (1, ) 2 Dimensions (1, ) (H x W x D) (1,811 1, ) Gross (1,811 1, ) 2 (1,811 1, ) Weight Net kg Gross Pipe Liquid diameter Gas Connection pipe Method Liquid Brazing Gas Brazing Max. length 150 m Max. height difference 50 / 40 (Outdoor unit : Upper / Lower) Operation temper- Cooling -5 to 46 CDB ature range Heating -20 to 21 Defrost method Reversed cycle Connectable indoor units Number Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. - (03-07) -

10 Nominal system capacity HP Set model name AJ 216LALHH AJ 234LALHH AJ 252LALHH AJ 270LALHH Model name (combination) AJ A90LALH Power source 3 Phase ~ 400 V, 50Hz Available voltage range 342 to 456 V Capacity Cooling kw Heating Input power Cooling kw Heating EER Cooling W / W COP Heating Type x Quantity Propeller fan x 3 Dimensions (H x W x D) Airflow rate High m 3 / h (l / s) 11,100 3 (3,084 3) 11,100 3 (3,084 3) 11,100 3 (3,084 3) Net (1, ) 3 (1, ) 3 (1, ) 3 Gross (1,811 1, ) 3 (1,811 1, ) 3 (1,811 1, ) 3 13, ,100 2 (3, ,084 2) Fan External static pressure (Max) Pa Motor Type x Quantity DC motor 3 Output W 700 x x x x 3 Sound pressure Cooling db(a) level Heating Length 1, , , , ,760 2 Fin pitch Rows x Stages (3 x 60) x 2 Heat exchanger Face area m Pipe type (Material) Grooved H-pin (Copper) Fin Type (Material) Corrugate (Aluminium) Surface treatment Corrosion resistance (Blue fin) Rotary(inv) x 3 Rotary(inv) x 3 Type x Quantity Rotary(inv) x 3 Rotary(inv) x 3 Scroll x 1 Scroll x 1 Compressor Motor output kw Crankcase heater W Refrigerant Type R410A Charge kg Refrigerant oil Type PVE Enclosure Material Painted galvanized steel Colour Beige (10YR 7.5/1.0NN) (1,690 1, ) (1, ) 2 (1,811 1, ) (1,811 1, ) Weight Net kg Gross Pipe Liquid diameter Gas Connection pipe Method Liquid Brazing Gas Brazing Max. length 150 m Max. height difference 50 / 40 (Outdoor unit : Upper / Lower) Operation temper- Cooling -5 to 46 CDB ature range Heating -20 to 21 Defrost method Reversed cycle Connectable indoor units Number Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. - (03-08) -

11 Nominal system capacity HP Set model name AJ 288LALHH AJ 306LALHH AJ 324LALHH Model name (combination) Power source 3 Phase ~ 400 V, 50Hz Available voltage range 342 to 456 V Capacity Cooling kw Heating Input power Cooling kw Heating EER Cooling W / W COP Heating Type x Quantity Propeller fan x 3 Dimensions (H x W x D) Airflow rate High m 3 / h (l / s) 11,100 3 (3,084 3) Net (1, ) 3 Gross (1,811 1, ) 3 13, ,100 2 (3, ,084 2) 13, ,100 (3, ,084) Fan External static pressure (Max) Pa Motor Type x Quantity DC motor 3 Output W 700 x x x 3 Sound pressure Cooling db(a) level Heating Length 1, , , , ,760 Fin pitch Rows x Stages (3 x 60) x 3 Heat exchanger Face area m Pipe type (Material) Grooved H-pin (Copper) Fin Type (Material) Corrugate (Aluminium) Surface treatment Corrosion resistance (Blue fin) Rotary(inv) x 3 Rotary(inv) x 3 Rotary(inv) x 3 Type x Quantity Scroll x 2 Scroll x 2 Scroll x 2 Compressor Motor output kw x Crankcase heater W x Refrigerant Type R410A Charge kg 11.8x Refrigerant oil Type PVE Enclosure Material Painted galvanized steel Colour Beige (10YR 7.5/1.0NN) (1,690 1, ) (1,690 1, ) 2 (1, ) 2 (1, ) (1,811 1, ) (1,811 1, ) 2 (1,811 1, ) 2 (1,811 1, ) Weight Net kg Gross Pipe Liquid diameter Gas Connection pipe Method Liquid Brazing Gas Brazing Max. length 150 m Max. height difference 50 / 40 (Outdoor unit : Upper / Lower) Operation temper- Cooling -5 to 46 CDB ature range Heating -20 to 21 Defrost method Reversed cycle Connectable indoor units Number Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. - (03-09) -

12 Nominal system capacity HP Set model name AJ 360LALHH AJ 378LALHH AJ 396LALHH Model name (combination) AJ 144LALH Power source 3 Phase ~ 400 V, 50Hz Available voltage range 342 to 456V Capacity Cooling kw Heating Input power Cooling kw Heating EER Cooling W / W COP Heating Type x Quantity Propeller fan x 3 Airflow rate High m 3 / h (l / s) 13, ,100 (3, ,084) 13,000 3 (3,611 3) 13,000 3 (3,611 3) Fan External static pressure (Max) Pa Motor Type x Quantity DC motor 3 Output W 700 x x x 3 Sound pressure Cooling db(a) level Heating Length 2, ,760 2, ,070 3 Fin pitch Rows x Stages (3 x 60) x 3 Heat exchanger Face area m Pipe type (Material) Grooved H-pin (Copper) Fin Type (Material) Corrugate (Aluminium) Surface treatment Corrosion resistance (Blue fin) Rotary(inv) x 3 Rotary(inv) x 3 Rotary(inv) x 3 Type x Quantity Scroll x 3 Scroll x 3 Scroll x 3 Compressor Motor output kw Crankcase heater W Refrigerant Type R410A Charge kg Refrigerant oil Type PVE Enclosure Material Painted galvanized steel Colour Beige (10YR 7.5/1.0NN) (1,690 1, ) 2 Net (1,690 1, ) 3 (1,690 1, ) 3 Dimensions (1, ) (H x W x D) (1,811 1, ) 2 Gross (1,811 1, ) 3 (1,811 1, ) 3 (1,811 1, ) Weight Net kg Gross Pipe Liquid diameter Gas Connection pipe Method Liquid Brazing Gas Brazing Max. length 150 m Max. height difference 50 / 40 (Outdoor unit : Upper / Lower) Operation temper- Cooling -5 to 46 CDB ature range Heating -20 to 21 Defrost method Reversed cycle Connectable indoor units Number Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating : Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. - (03-10) -

13 222DIMENSIONS 22222SINGLE UNIT MODELS :, AJ A90LALH, 690 (Bolt pitch) 530 (Bolt pitch) 8-12x17 (Hole) (Unit : ) 732 (Bolt pitch) Top view Left view B A, C Front view Right view 930 Rear view - (03-11) -

14 MODELS :, AJ 144LALH 1000 (Bolt pitch) 840 (Bolt pitch) 8-12x17 (Hole) (Unit : ) Top view 732 (Bolt pitch) Left view B A, C Front view Right view 1240 Rear view - (03-12) -

15 KNOCKOUT HOLE POSITION (Unit : ) Ø 50 Power supply cable port Ø 34.5 Power supply cable port Ø 43.7 Power supply cable port Ø 22.2 Transmission cable port Ø 22.2 Transmission cable port Pipe port Ø 50 Power supply cable port Ø 22.2 Transmission cable port Ø 34.5 Power supply cable port Detail A : Front view Detail B : Left view Pipe port 82 Ø 43.7 Power supply cable port Ø 22.2 Transmission cable port Detail C : Top view - (03-13) -

16 VALVE POSITION (Unit : ) Liquid valve Gas valve Liquid valve Gas valve D : Front view E : Left view ACCESSORY PIPE Liquid Gas Liquid Gas F : Left view (Accessory pipe A setting) G : Left view (Accessory pipe B setting) - (03-14) -

17 INSTALLATION (FOUNDATION) (Unit : ) Model A B AJ A90LALH AJ 144LALH x 17 (Hole) Bottom view Installation example Bolt (M10) No good OK OK *Do not use a four-corner support foundation. More than 200 When installing pipe from the bottom of the outdoor units, the required space under the outdoor unit (03-15) -

18 CENTER OF GRAVITY POSITION zmodels :, AJ A90LALH, (Unit : ) AJ A72 AJ A90 AJ 108 : Center of gravity zmodels :, AJ 144LALH : Center of gravity - (03-16) -

19 22222COMBINATION Combination Set model name Outdoor unit1 Outdoor unit2 Space Saving AJ 162LALH (18HP) 10HP 8HP Space Saving AJ 1LALH (20HP) 12HP 8HP Space Saving AJ 198LALH (22HP) 12HP 10HP Space Saving AJ 216LALH (24HP) 12HP 12HP Energy Efficiency AJ 144LALHH (16HP) 8HP 8HP 610 (Bolt pitch) 610 (Bolt pitch) (Unit : ) 8-12x17 (Hole) 8-12x17 (Hole) 732 (Bolt pitch) Top view 1690 Outdoor unit 1 Outdoor unit Front view - (03-17) -

20 Combination Set model name Outdoor unit1 Outdoor unit2 Space Saving AJ 234LALH (26HP) 14HP 12HP Space Saving AJ 252LALH (28HP) 16HP 12HP Energy Efficiency AJ 198LALHH (22HP) 14HP 8HP 920 (Bolt pitch) 610 (Bolt pitch) (Unit : ) 8-12x17 (Hole) 8-12x17 (Hole) Top view (Bolt pitch) Outdoor unit 1 Outdoor unit Front view - (03-18) -

21 Combination Set model name Outdoor unit1 Outdoor unit2 Space Saving AJ 270LALH (30HP) 16HP 14HP Space Saving AJ 288LALH (32HP) 16HP 16HP 920 (Bolt pitch) 920 (Bolt pitch) (Unit : ) 8-12x17 (Hole) 8-12x17 (Hole) Top view (Bolt pitch) Outdoor unit 1 Outdoor unit Front view - (03-19) -

22 Combination Set model name Outdoor unit1 Outdoor unit2 Outdoor unit3 Space Saving AJ 306LALH (34HP) 12HP 12HP 10HP Space Saving AJ 324LALH (36HP) 12HP 12HP 12HP Energy Efficiency AJ 216LALHH (24HP) 8HP 8HP 8HP Energy Efficiency AJ 234LALHH (26HP) 10HP 8HP 8HP Energy Efficiency AJ 252LALHH (28HP) 12HP 8HP 8HP Energy Efficiency AJ 288LALHH (32HP) 12HP 12HP 8HP (Unit : ) 610 (Bolt pitch) 610 (Bolt pitch) 610 (Bolt pitch) 8-12x17 (Hole) 8-12x17 (Hole) Top view (Bolt pitch) 8-12x17 (Hole) Outdoor unit 1 Outdoor unit 2 Outdoor unit Front view - (03-20) -

23 Combination Set model name Outdoor unit1 Outdoor unit2 Outdoor unit3 Space Saving AJ 342LALH (38HP) 14HP 12HP 12HP Space Saving AJ 360LALH (40HP) 16HP 12HP 12HP Energy Efficiency AJ 270LALHH (30HP) 14HP 8HP 8HP Energy Efficiency AJ 306LALHH (34HP) 14HP 12HP 8HP 920 (Bolt pitch) 610 (Bolt pitch) 610 (Bolt pitch) (Unit : ) 8-12x17 (Hole) 8-12x17 (Hole) 732 (Bolt pitch) Top view x17 (Hole) Outdoor unit 1 Outdoor unit 2 Outdoor unit Front view - (03-21) -

24 Combination Set model name Outdoor unit1 Outdoor unit2 Outdoor unit3 Space Saving AJ 378LALH (42HP) 16HP 14HP 12HP Space Saving AJ 396LALH (44HP) 16HP 16HP 12HP Energy Efficiency AJ 324LALHH (36HP) 14HP 14HP 8HP Energy Efficiency AJ 360LALHH (40HP) 14HP 14HP 12HP 920 (Bolt pitch) 920 (Bolt pitch) 610 (Bolt pitch) (Unit : ) 8-12x17 (Hole) 8-12x17 (Hole) 732 (Bolt pitch) Top view x17 (Hole) Outdoor unit 1 Outdoor unit 2 Outdoor unit Front view - (03-22) -

25 Combination Set model name Outdoor unit1 Outdoor unit2 Outdoor unit3 Space Saving AJ 414LALH (46HP) 16HP 16HP 14HP Space Saving AJ 432LALH (48HP) 16HP 16HP 16HP Energy Efficiency AJ 378LALHH (42HP) 14HP 14HP 14HP Energy Efficiency AJ 396LALHH (44HP) 16HP 14HP 14HP 920 (Bolt pitch) 920 (Bolt pitch) 920 (Bolt pitch) (Unit : ) 8-12x17 (Hole) 8-12x17 (Hole) Top view (Bolt pitch) 8-12x17 (Hole) Outdoor unit 1 Outdoor unit 2 Outdoor unit Front view - (03-23) -

26 333INSTALLATION SPACE Caution When installing the outdoor unit, pay attention to the following items. To prevent stopping of operation by short circuit and worsening of performance and high pressure protection, refer to the installation space shown in the figure and secure enough space. Install in sufficient space considering the carrying in route, installation space, maintenance space, passage of people, etc. Do not place obstructions in the air flow outlet direction. If there is an obstruction in the outlet direction, install an outlet duct. When there is a wall in front of the unit, provide a space of 500 as maintenance space. When there is a wall at the left side of the unit, provide a space of 30 as maintenance space. When installing, also consider the refrigerant piping space. An outdoor temperature of 35 C (DB) in air-conditioned operation is assumed for the installation space in this item. If the outdoor temperature exceeds 35 C (DB) and the outdoor unit is operating at a load exceeding its rated ability, provide a larger inlet space WHEN INSTALL NEAR BY LIMITED HEIGHT WALL SINGLE AND MULTIPLE INSTALLATIONS There are no restrictions on the height of the side wall. Provide installation spaces L1 and L2 in accordance with the table below according to the wall height (front side, side) conditions. Provide installation spaces other than L1 and L2 in accordance with the conditions shown in the figure below. Ventilation resistance can be ignorable when the distance from a wall or product, etc. is larger than 2m. Wall height condition When H1 is 1500() or less When H1 is 1500() When H2 is 500() or less When H2 is 500() Necessary installation space L1 500 () L h1 2 () L2 100 () L h2 2 () Front Rear 1500 H1 h1 Side wall Side wall 500 h2 H2 <Front view> Wall L1 <Side view> L2 Wall Single installation Multiple installations L2 Rear Rear L2 Side wall Front L1 Side wall Side wall Front L1 Side wall <Top view> <Top view> (03-24) -

27 CONCENTRATED INSTALLATION Provide installation spaces L3, L4, and L5 in accordance with the table below according to the wall height (front side, side) conditions. Provide installation spaces other than L3, L4, and L5 in accordance with the conditions shown in the figure below. Ventilation resistance can be ignorable when the distance from a wall or product, etc. is larger than 2m. Wall height condition When H3 is 1500() or less When H3 is 1500() When H4 is 500() or less When H4 is 500() When H5 is 500() or less When H5 is 500() Necessary installation space L3 500 () L h3 2 () L4 200 () L h4 2 () L5 200 () L h5 2 () Front Rear 500 h4 H4 H5 500 h5 500 h5 H H3 h3 Wall L3 <Side view> L4 Wall Wall L5 <Front view> L5 Wall Rear L4 Rear L4 Front Rear 0 Front Front 500 Front Rear 0 Rear Rear 1000 Front <Top view> L3 Front <Top view> L3 L L5 L L5 - (03-25) -

28 33333WHEN INSTALL NEAR BY UNLIMITED HEIGHT WALL SINGLE AND MULTIPLE INSTALLATIONS There are no restrictions on the height of the wall. The wall (without height restrictions) must not exist on the both sides (left / right) of outdoor unit. Also, must not exist on the both sides (front / ) of outdoor unit. Provide installation spaces other than L6 in accordance with the conditions shown in the figure below. Ventilation resistance can be ignorable when the distance from a wall or product, etc. is larger than 2m. zwhen installing with the REAR of the outdoor unit facing the wall side Condition When B 400 () When 20 B < 400 () Necessary installation space L6 200 () L (400 - B) x 3 () Single installation Multiple installations <Top view> Rear Wall 100 Rear <Top view> Wall L6 Wall Front Wall Front B <Top view> B Wall Wall Example : When B is made 200 L6 200+( )x3=0 Rear Front zwhen installing with the FRONT of the outdoor unit facing the wall side <Top view> Wall <Top view> Wall Wall Front 500 Wall Front Rear 200 Rear (03-26) -

29 CONCENTRATED INSTALLATION The wall (without height restrictions) must not exist on the both sides (left / right) of outdoor unit. Also, must not exist on the both sides (front / ) of outdoor unit. Ventilation resistance can be ignorable when the distance from a wall or product, etc. is larger than 2m. <Top view> Wall Rear 400 Front Rear 0 Front Rear 0 Front <Top view> Wall Rear 400 Front Front 500 Wall Wall Rear Rear 1000 Front (03-27) -

30 33333WHEN THERE IS AN OBSTRUCTION ABOVE THE PRODUCT When there is an obstruction above the product, observe the minimum installation height and install an outlet duct as shown in the figure. When an outlet duct, etc. is installed; the high static pressure mode must be set by pushbutton switch. (Also applies when a snow hood was installed) Outlet duct 500 zhigh static pressure mode setting Select the high static pressure mode in accordance with the table below. Condition High static pressure mode setting *2 Static Pressure(SP) *1 : 0 SP 30 (Pa) Set to Mode 1 Static Pressure(SP) *1 : 30 < SP (Pa) Set to Mode 2 *1 : Static pressure is the air flow resistance that includs the discharge duct resistance & the other additional resistance like discharge grill and so on. *2 : Refer to the section on Push Switch Setting in "6-6.FUNCTION SETTING". zwhen an outlet duct is not installed, install the product as shown below. 1) Make the ceiling height after setting 1m or greater. 2) Be sure there is no wall at the side. 3) When installing products adjacently, install up to 3 units front (03-28) -

31 33333CONCENTRATED INSTALLATION EXAMPLE When installing units in a group, in the worst case, the drop of capacity of outdoor units due to short circuiting of the outlet air of the outdoor units installed at the periphery may reach stopping of the equipment. Basic installation examples of 12 and 24 units are shown below. Always secure the distances of the given value or greater. To prevent a drop of capacity due to a short circuit, install a mount at the bottom of the body and consider design which secures a ventilation path, etc. at the bottom of the wall. In addition, when installing more than the above number of units, provide ample space of the dimension shown below or greater, or when you cannot make a judgment, contact your dealer. CONCENTRATED INSTALLATION EXAMPLE (1) *Wall height: All 500 z12 units installation example front front front front front front z24 units installation example 200 front front front front (03-29) -

32 CONCENTRATED INSTALLATION EXAMPLE (2) *Wall height: All *However, the height of the wall can be unrestricted. z12 units installation example 0 front front front front front front z24 units installation example 0 front front front front (03-30) -

33 CONCENTRATED INSTALLATION EXAMPLE (3) *Wall height is unrestricted. * Of the 4 directions, leave at least 2 directions open. Leave either the front or back direction open. z12 units installation example Installation of more than the number of units shown below is not recoended because short circuit easily occurs at the corners. front front front front front front (03-31) -

34 33333INSTALLATION ON EACH FLOOR Precautions when installing on each floor z When installing the product on each floor, be careful because updraft may cause a short circuit. If a short circuit occurred, the cooling and heating capacity and EER, COP (efficiency) may drop and in the worst case, high pressure protection may cause operation to stop. Regarding the installation dimensions, refer to the figure below and provide an ample intake space. Provide service space and refrigerant piping and electric wiring space. Install an outlet duct at each outdoor unit. zinstallation example when installed on each floor An installation example assuming conditions like those shown in the table below is shown in the figure below Height / floor Capacity / floor Number of installable floors HP 20 floors When substantially different from this installation example, be amply careful of short circuit, etc Make the outlet wind velocity Vo = 5.5m/s to 7.5m/s. Make the intake wind velocity of opening Vi = 1.2m/s or less [Example of each floor] Vi (4000) 500 Vo front or less zwhen installing a louver When installing a louver, pay attention to the following: Fit the outlet duct tightly to the louver so that short circuit will not occur. Make the louver angle 0 to 20 down. If installed facing up, short circuit is easily generated by updraft. Make the opening ratio of the outlet louver 75% or greater. - (03-32) -

35 444REFRIGERANT CIRCUIT MODELS :, AJ A90LALH Outdoor unit FAN1 TH5 EEV2 TH8 HPS HEX EEV1 TH6 SCHEX TH9 TH7 HPSW1 TH4 TH3 TH1 OS SV1 LPS TH10 CMP1 INV SV2 CMP ACM ACM SV3 Indoor unit1 TH21 FAN21 TH23 HEX21 TH22 EEV21 LIQUID LINE GAS LINE Indoor unit2 TH21 FAN21 TH23 HEX21 TH22 EEV21 : Check valve : Capillary : Strainer : 3-way valve : Service port : Pressure regulation valve - (03-33) -

36 MODEL : Outdoor unit FA N1 TH5 EEV 2 TH8 H PS HEX EEV 1 TH6 SC H EX TH9 TH7 H PSW1 H PSW2 TH4 TH3 TH1 C M P1 IN V OS OS SV 1 TH2 TH11 C M P2 SV 2 LPS CMP A CM SV 6 SV 3 Indoor unit1 TH21 FAN21 TH23 HEX21 TH22 EEV21 LIQUID LINE GAS LINE Indoor unit2 TH21 FAN21 TH23 HEX21 TH22 EEV21 : Check valve : Capillary : Strainer : 3-way valve : Service port : Pressure regulation valve - (03-34) -

37 MODELS :, AJ 144LALH Outdoor unit FA N1 TH5 SV 5 EEV 2 TH8 H PS HEX EEV 1 TH6 SC H EX TH9 TH7 H PSW1 H PSW2 TH4 TH3 TH10 TH1 C M P1 IN V OS OS SV 1 TH2 TH11 SV 2 C M P2 LPS CMP A CM SV 3 Indoor unit1 TH21 FAN21 TH23 HEX21 TH22 EEV21 LIQUID LINE GAS LINE Indoor unit2 TH21 FAN21 TH23 HEX21 TH22 EEV21 : Check valve : Capillary : Strainer : 3-way valve : Service port : Pressure regulation valve - (03-35) -

38 SYMBOL DESCRIPTION zoutdoor unit MARK DESCRIPTION CMP 1 Compressor 1 (Inverter type) CMP 2 Compressor 2 (Constant speed type) HEX Heat exchanger FAN 1 Fan 1 ACM Accumulator RCV Receiver tanker OS Oil separator SCHEX Sub-cool heat exchanger HPS High pressure sensor LPS Low pressure sensor HPSW1 High pressure sensor switch 1 4WV 4-way valve EEV 1 Electric expansion valve 1 EEV 2 Electric expansion valve 2 SV 1 Solenoid valve 1 SV 2 Solenoid valve 2 SV 3 Solenoid valve 3 SV 5 Solenoid valve 5 SV 6 Solenoid valve 6 Marking (Tube) TH 1 Discharge temperature thermistor 1 Blue TH 2 Discharge temperature thermistor 2 Yellow TH 3 Outdoor temperature thermistor TH 4 Suction temperature thermistor Red TH 5 Heat exchanger (outlet) thermistor TH 6 Liquid temperature thermistor 1 Gray TH 7 Liquid temperature thermistor 2 Green TH 8 Sub-cool heat exchanger (inlet) thermistor White TH 9 Sub-cool heat exchanger (outlet) thermistor TH 10 Compressor 1 temperature thermistor TH 11 Compressor 2 temperature thermistor zindoor unit MARK DESCRIPTION HEX 21 Heat exchanger FAN 21 Fan EEV 21 Electric expansion valve TH 21 Room temperature thermistor TH 22 Heat exchanger (inlet) thermistor TH 23 Heat exchanger (outlet) thermistor - (03-36) -

39 555WIRING DIAGRAM MODELS :, AJ A90LALH Note : *1 X1, X2 : To be connected to indoor units Z1, Z2 : To be connected to other master outdoor unit H1, H2 : To be connected to outdoor unit within same refrigerant system *1 - (03-37) -

40 MODEL : *1 Note : *1 X1, X2 : To be connected to indoor units Z1, Z2 : To be connected to other master outdoor unit H1, H2 : To be connected to outdoor unit within same refrigerant system - (03-38) -

41 MODELS :, AJ 144LALH Note : *1 X1, X2 : To be connected to indoor units Z1, Z2 : To be connected to other master outdoor unit H1, H2 : To be connected to outdoor unit within same refrigerant system *1 - (03-39) -

42 666OPERATION RANGE SINGLE USE Operation mode Cooling / Dry Operation range Indoor unit Outdoor unit 18 to 32 C DB R.H. % or less -15 to 46 C DB Heating 10 to 30 C DB -20 to 21 C DB R.H. : Relative Humidity. MULTIPLE USE Operation mode Cooling / Dry Operation range Indoor unit Outdoor unit 18 to 32 C DB R.H. % or less -5 to 46 C DB Heating 10 to 30 C DB -20 to 21 C DB R.H. : Relative Humidity. - (03-40) -

43 777NOISE LEVEL CURVE MODEL : zcooling Heating Rated Rated NC-65 NC-65 Octave band sound pressure level, db:(0db=0.0002µbar) Low noise mode level 2 Low noise mode level 1 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 Octave band sound pressure level, db:(0db=0.0002µbar) Low noise mode level 2 Low noise mode level 1 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC-15 NC ,000 2,000 4,000 8,000 Octave band center frequency, Hz MODEL : AJ A90LALH zcooling Heating ,000 2,000 4,000 8,000 Octave band center frequency, Hz 70 Rated 70 Rated Octave band sound pressure level, db:(0db=0.0002µbar) Low noise mode level 1 Low noise mode level 2 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 Octave band sound pressure level, db:(0db=0.0002µbar) Low noise mode level 1 Low noise mode level 2 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC-15 NC ,000 2,000 4,000 8,000 Octave band center frequency, Hz ,000 2,000 4,000 8,000 Octave band center frequency, Hz - (03-41) -

44 MODEL : zcooling Heating Rated Rated Octave band sound pressure level, db:(0db=0.0002µbar) Low noise mode level 1 Low noise mode level 2 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 Octave band sound pressure level, db:(0db=0.0002µbar) Low noise mode level 1 Low noise mode level 2 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC-15 NC ,000 2,000 4,000 8,000 Octave band center frequency, Hz MODEL : zcooling Heating ,000 2,000 4,000 8,000 Octave band center frequency, Hz 70 Rated 70 Rated Octave band sound pressure level, db:(0db=0.0002µbar) Low noise mode level 1 Low noise mode level 2 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 Octave band sound pressure level, db:(0db=0.0002µbar) Low noise mode level 1 Low noise mode level 2 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC-15 NC ,000 2,000 4,000 8,000 Octave band center frequency, Hz ,000 2,000 4,000 8,000 Octave band center frequency, Hz - (03-42) -

45 MODEL : AJ 144LALH zcooling Heating 70 Rated 70 Rated Octave band sound pressure level, db:(0db=0.0002µbar) Low noise mode level 1 Low noise mode level 2 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 Octave band sound pressure level, db:(0db=0.0002µbar) Low noise mode level 1 Low noise mode level 2 NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC-15 NC ,000 2,000 4,000 8,000 Octave band center frequency, Hz ,000 2,000 4,000 8,000 Octave band center frequency, Hz - (03-43) -

46 SOUND LEVEL CHECK POINT Microphone 1 m 1 m - (03-44) -

47 888ELECTRIC CHARACTERISTICS SPACE SAVING COMBINATION HP Model name Hz Rated Value Electric Characteristics Power Supply Full Load Characteristics Wiring Specifications *1 Compresser Voltage (V) MCA (A) TOCA (A) MSC (A) MFA (A) Power Cable ( 2 ) Earth Cable ( 2 ) Limied Wiring Length (m) *2 RLA (A) Outdoor Fan Motor Output (kw) FLA (A) 8HP HP AJ A90LALH HP HP HP AJ 144LALH Select the breaker based on MCA of the table above. Select the wire diameter based on the larger value of MCA or TOCA of the table above and select a wire diameter which withstands the breaker capacity. *1 Wiring Spec : These values are recoended data. Please select the wiring spec in accordance with local rules. *2 Limited Wiring Length : This wiring length is in case voltage drop less than 2%. When wiring length extend longer, select the wiring size of larger diameter. RLA : Rated Load Amp of compressor under the standard condition. MCA : Min Circuit Amp = Max Operating Current (Full Load) MSC : Max Starting Current TOCA : Total Value of Each Over Current Set MFA : Main Fuse (Circuit Breaker) Current - (03-45) -

48 Rated Value Power Supply Electric Characteristics Full Load Characteristics HP Set model name Model name Hz Voltage (V) MCA (A) TOCA (A) MSC (A) 18HP AJ 162LALH AJ A90LALH HP AJ 1LALH HP AJ 198LALH AJ A90LALH HP 26HP AJ 216LALH AJ 234LALH HP AJ 252LALH AJ 144LALH HP AJ 270LALH AJ 144LALH HP AJ 288LALH AJ 144LALH AJ 144LALH HP AJ 306LALH AJ A90LALH HP AJ 324LALH HP AJ 342LALH HP AJ 360LALH AJ 144LALH HP AJ 378LALH AJ 144LALH HP AJ 396LALH AJ 144LALH AJ 144LALH HP AJ 414LALH AJ 144LALH AJ 144LALH HP AJ 432LALH AJ 144LALH AJ 144LALH AJ 144LALH Select the breaker based on MCA of the table above. Select the wire diameter based on the larger value of MCA or TOCA of the table above and select a wire diameter which withstands the breaker capacity. *1 Wiring Spec : These values are recoended data. Please select the wiring spec in accordance with local rules. *2 Limited Wiring Length : This wiring length is in case voltage drop less than 2%. When wiring length extend longer, select the wiring size of larger diameter. RLA : Rated Load Amp of compressor under the standard condition. MCA : Min Circuit Amp = Max Operating Current (Full Load) MSC : Max Starting Current TOCA : Total Value of Each Over Current Set MFA : Main Fuse (Circuit Breaker) Current - (03-46) -

49 ENERGY EFFICIENCY COMBINATION Rated Value Power Supply Electric Characteristics Full Load Characteristics HP Set model name Model name Hz Voltage (V) MCA (A) TOCA (A) MSC (A) 16HP AJ 144LALHH HP AJ 198LALHH HP AJ 216LALHH HP 28HP AJ 234LALHH AJ 252LALHH AJ A90LALH HP AJ 270LALHH HP AJ 288LALHH HP AJ 306LALHH HP AJ 324LALHH HP AJ 360LALHH HP AJ 378LALHH HP AJ 396LALHH AJ 144LALH Select the breaker based on MCA of the table above. Select the wire diameter based on the larger value of MCA or TOCA of the table above and select a wire diameter which withstands the breaker capacity. *1 Wiring Spec : These values are recoended data. Please select the wiring spec in accordance with local rules. *2 Limited Wiring Length : This wiring length is in case voltage drop less than 2%. When wiring length extend longer, select the wiring size of larger diameter. RLA : Rated Load Amp of compressor under the standard condition. MCA : Min Circuit Amp = Max Operating Current (Full Load) MSC : Max Starting Current TOCA : Total Value of Each Over Current Set MFA : Main Fuse (Circuit Breaker) Current - (03-47) -

50 999SAFETY DEVICES Safety device AJ A90LALH AJ 144LALH Fuse (Main PCB) AC 250V 3.15A AC 500V 15A Protector (INV PCB) AC 500V 25A INV Overcurrent protection - COMP Temperature protection Off : 110 C On : C Temperature protection Compressor Off:155 C±5(0A) On: C±11(0A) Protector CONST Minimum operation current COMP On:14.4A(120 C) Off:20.0A(120 C) Over current protection 3-10sec 59.0A High Pressure Protection Off : 4.2MPa On : 3.2MPa Low Pressure Protection Off : 0.05MPa - (03-48) -

51 LOCALLY PROCURED PARTS AIR DISCHARGE DUCT PRECAUTION (Unit : ) All the components/parts such as the duct, frame, and screws are to be locally procured. Do not install the duct where seasonal wind blow directly against to the discharge port. Install so that the static pressure of the air flow path, including the duct is Pa or less. Note that installation of the duct increases the height of the cabinet. If installation space may narrow, like as consecutive unit layout, be sure to fix the duct to the unit before placing the unit. When the duct is installed, the noise may become louder. DUCT LAYOUT EXAMPLE Chamfer or a round the corner Model AJ A90LALH AJ 144LALH Dimension C (Minimum) (Maximum) Caution Make the height A of the duct opening section 500 or greater. Make the height B of the duct, excluding the flange 500 or greater. Make the width (dimension C) of the duct within the range of the table shown above. Provide a Chamfer or round the corner at the air flow path. Design the duct weight with 100kg or less as the standard. Design the duct so that maintenance of the motor is possible. When the length of the duct is long, provide support material at suitable intervals. - (03-49) -

HP switch LP switch Discharge thermo Comp. Surface thermo

HP switch LP switch Discharge thermo Comp. Surface thermo 1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................

More information

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1 SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH

More information

Appendix - Controllers 179

Appendix - Controllers 179 Version: 200703 Appendix - Controllers 179 -3- -4- -5- -6- -7- -8- 2. Specifications 2.1 Specifications for inverter units item Model AB182ACERA Function cooling heating Capacity kw 5.01.8--5.8 5.22.0---6.2

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED

More information

Air Conditioners. Technical Data. Wall Mounted Unit. www.daikin.eu RX-JV/GV

Air Conditioners. Technical Data. Wall Mounted Unit. www.daikin.eu RX-JV/GV Air Conditioners Technical Data Wall Mounted Unit www.daikin.eu RX-JV/GV Air Conditioners Technical Data Wall Mounted Unit www.daikin.eu RX-JV/GV TABLE OF CONTENTS RX-JV/GV 1 Features.............................................................

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LECA AS G09LECA AS G12LECA AS G14LECA OUTDOOR AO G07LEC AO G09LEC AO G12LEC AO G14LEC 1. INDOOR UNIT : AS G07LECA AS G09LECA AS

More information

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LKC AS A12LKC OUTDOOR AO R09LKC AO R12LKC 1.INDOOR UNIT : AS A09LKC AS A12LKC DTR_AS039E_01 2010.02.24 1. INDOOR UNIT CONTENTS 1.

More information

NEW 3-PIPE ECOi MF2 SERIES

NEW 3-PIPE ECOi MF2 SERIES NEW 3-PIPE ECOi MF2 SERIES SIMULTANEOUS HEATING AND COOLING VRF SYSTEM Internet Control Ready INTERNET CONTROL NEW Energy Environmentally friendly refrigerant R410A Down to -20 ºC in heating mode OUTDOOR

More information

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability PFD-P250VM-E PUHY-P250YJM-A(-BS) PUHY-P500YSJM-A(-BS) PQHY-P250YHM-A CLOSE CONTROL SYSTEM MITSUBISHI ELECTRIC s Close Control System (PFD series) is specifically designed for computer rooms, laboratories

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05 TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation

More information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor

More information

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system. ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2

More information

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER

More information

Inverter Air Conditioning for Light Commercial Use

Inverter Air Conditioning for Light Commercial Use Inverter Air Conditioning for Light Commercial Use 02 Cost Saving Comfort An efficient use of time 03 SDISuper Digital Inverter Very efficient energy consumption Keeps down operating costs Heater operation

More information

DM13-01.01.01en. Service manual MIV V5 HEAT PUMP DC INVERTER R410A MVUH252B-VA3 MVUH280B-VA3 MVUH335B-VA3 MVUH400B-VA3 MVUH450B-VA3 MVUH500B-VA3

DM13-01.01.01en. Service manual MIV V5 HEAT PUMP DC INVERTER R410A MVUH252B-VA3 MVUH280B-VA3 MVUH335B-VA3 MVUH400B-VA3 MVUH450B-VA3 MVUH500B-VA3 DM13-01.01.01en Service manual MIV V5 HEAT PUMP DC INVERTER R410A MVUH252B-VA3 MVUH280B-VA3 MVUH335B-VA3 MVUH400B-VA3 MVUH450B-VA3 MVUH500B-VA3 Contents Part 1 General Information... 1 Part 2 Selection

More information

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ SERVICE MANUAL Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ FS2MI-147HFD FS2MI-187HFD FS3MI-217HFD FS3MI-277HFD FS4MI-277HFD FS4MI-367HFD FS5MI-367HFD NOTE: Before servicing the

More information

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating

More information

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO.

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO. TECHNICAL & SERVICE MANUAL SAP K161GJA SAP K181GJA SAP K181MBA SAP K241GJA SAP K241MBA + SAP C161GA + SAP C161JA + SAP C181GA + SAP C181JA + SAP C181MA + SAP C181BA + SAP C241GA + SAP C241JA + SAP C241MA

More information

FULL DC INVERTER SYSTEMS

FULL DC INVERTER SYSTEMS FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation

More information

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy LG Air conditioning Company Multi V Water Ⅱ Air Conditioning Academy 1.1 What is Multi V Water II? High Performance Prospect rights Water pipe Refrigerant pipe Indoor unit Beautiful Exterior Convenience

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS

More information

Condensing unit type EPSILON-ECHOS LE Technical information manual

Condensing unit type EPSILON-ECHOS LE Technical information manual Condensing unit type EPSILON-ECHOS LE Technical information manual 2 > EPSILON ECHOS Water chiller > EPSILON ECHOS /HP Reversible heat pump > EPSILON ECHOS /ST Water chiller with storage tank and pumps

More information

Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and

Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and 1 Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and cost-effective, Toshiba aims at the heart of growing

More information

Air Conditioning For Large Buildings

Air Conditioning For Large Buildings Air Conditioning For Large Buildings Index Introduction 3 Industry leading energy savings 6 New smart & sensitive VRF control 10 Industry leading layout flexibility 14 Other features 18 Outdoor units Outdoor

More information

CRAC Precision climate control units for data centres

CRAC Precision climate control units for data centres CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have

More information

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.

More information

SECTION 15732 AIR CONDITIONING UNIT

SECTION 15732 AIR CONDITIONING UNIT SECTION 15732 AIR CONDITIONING UNIT PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Packaged, split system air conditioning unit No. 1. 1.02 REFERENCES A. Air-Conditioning, Heating, and Refrigeration

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : AEMI0AH AEMIAHB AEMIAH AEMI0AH FILE NO. Destination: Europe DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity.0k.k.k.0k Outdoor Model No. AEMI0AH AEMIAHB AEMIAH

More information

AquaFREE system. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE

AquaFREE system. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE AquaFREE system Technical Catalogue Outdoor units: RAS(3~5)HVRNE RAS(4/5)HRNE Indoor units: RWM(3~5)FSN1E RWM(3~5)FSN1E(4.5/6)H(1/3) RWM(3~5)FSN1ES1 RWM(3~5)FSN1E(4.5/6)SH(1/3) Specifications in this

More information

TWE+TTA TWE+TWA 6.25-20 T.R.

TWE+TTA TWE+TWA 6.25-20 T.R. TWE+TTA TWE+TWA 6.25-20 T.R. Main features : TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drive centrifugal fan motor. Aluminium fin coil with copper-tubes.

More information

SECTION 23 81 43 HEAT PUMPS

SECTION 23 81 43 HEAT PUMPS SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XR17 4TTR7 2, 3, 4 & 5 Tons PUB. NO. 22-1884-01 Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER All Aluminum SPINE FIN coil DURATUFF

More information

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

REGULINE 600VA / 1000VA REGULATOR USER MANUAL REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate

More information

SERVICE MANUAL MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUZ-GE18NA MUZ-GE24NA MUY-GE09NA MUY-GE12NA MUY-GE15NA MUY-GE18NA MUY-GE24NA OUTDOOR UNIT

SERVICE MANUAL MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUZ-GE18NA MUZ-GE24NA MUY-GE09NA MUY-GE12NA MUY-GE15NA MUY-GE18NA MUY-GE24NA OUTDOOR UNIT SPLIT-TYPE AIR CONDITIONERS Revision B: Descriptions regarding the outdoor fan motor have been corrected. Please void OBH549 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH549 REVISED

More information

Unico Inverter. Unique and efficient.

Unico Inverter. Unique and efficient. Unico Inverter. Unique and efficient. INTERNATIONAL PATENT PENDING The first fixed air conditioner without outdoor unit featuring DC Inverter technology. Great performance, reduced consumption. Designed

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-01 Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess

More information

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4. AquaFREE System Technical Catalogue Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.5/6)H(1/3) Specifications in this manual are subject to change without notice

More information

Failure code manual. content

Failure code manual. content Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一

More information

MAC-120HE-01 Air-Cooled Chiller

MAC-120HE-01 Air-Cooled Chiller MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01

More information

Multi Air Conditioning System for Buildings

Multi Air Conditioning System for Buildings Multi Air Conditioning System for Buildings 6, Suenaga, Takatsuku, Kawasaki 238502, Japan http://www.fujitsugeneral.com/ ISO 900 ISO 400 ISO 900 ISO 400 Certified number : 0 00 89394 Certified number :

More information

AIR CONDITIONER INSTALLATION MANUAL

AIR CONDITIONER INSTALLATION MANUAL INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by

More information

SERVICE MANUAL OUTDOOR UNIT MUZ-A09NA,- 1,- U1,- U2 MUZ-A12NA,- U1 MUZ-A15NA,- U1 MUZ-A17NA,- U1 MUY-A15NA MUY-A17NA MUY-A24NA,- 1,- U1,- U2

SERVICE MANUAL OUTDOOR UNIT MUZ-A09NA,- 1,- U1,- U2 MUZ-A12NA,- U1 MUZ-A15NA,- U1 MUZ-A17NA,- U1 MUY-A15NA MUY-A17NA MUY-A24NA,- 1,- U1,- U2 SPLIT-TYPE AIR CONDITIONERS Revision E: MUZ-GA24NA and MUY-GA24NA have been added. Please void OB451 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OB451 REVISED EDITION-E Models MUZ-A09NA,-

More information

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-A Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs

More information

SWIMMING POOL HEAT PUMP

SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical

More information

AIR-TO-WATER HEAT PUMP (50Hz/R410A) 5BPU0-03C(Replace:5BPU0-03B)

AIR-TO-WATER HEAT PUMP (50Hz/R410A) 5BPU0-03C(Replace:5BPU0-03B) AIR-TO-WATER HEAT PUMP (50Hz/R410A) 5BPU0-03C(Replace:5BPU0-03B) CONTENTS Part 1. Indoor Unit(Hydro kit) Part 2. Outdoor Unit Part 3. Accessories Part 1. Indoor Unit (Hydro kit) 1. Features 2. Nomenclature

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Silver 14 4A6H4 1 1 /2-5 Tons PUB. NO. 12-1175-07 Contents Features and Benefits 2 Model Nomenclature 3 General 4 Product Specifications 4 A-weighted Sound Power Level [db(a)]

More information

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Hitachi Air Conditioning Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Contents Page 04 Product Range 08-09 RAC Summit Wall Mounted 10 RAC Shirokuma Wall mounted 11 RAC S Series - Wall

More information

Product Data. Split System Cooling 22-1904-1F-EN. March 2015

Product Data. Split System Cooling 22-1904-1F-EN. March 2015 Product Data Split System Cooling 4TTR4018L1000A 4TTR4024L1000A 4TTR4025L1000A 4TTR4030L1000A 4TTR4031L1000A 4TTR4036L1000A 4TTR4037L1000A 4TTR4042L1000A 4TTR4043L1000A 4TTR4048L1000A 4TTR4060L1000A Note:

More information

VRF CATALOGUE HEAT PUMP & HEAT RECOVERY. for Europe. Variable Refrigerant Flow System

VRF CATALOGUE HEAT PUMP & HEAT RECOVERY. for Europe. Variable Refrigerant Flow System VRF Variable Refrigerant Flow System CATALOGUE HEAT PUMP & HEAT RECOVERY for Europe Fujitsu General have been developing and manufacturing high quality and energy efficient products for more than 35 years.

More information

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español Split-type Air-Conditioner MXZ-3A30NA MXZ-4A36NA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Français Español ATTENTION This manual mentions

More information

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Data XL20i 4TWZ0024, 036, 048 & 060 with ComfortLink II and Charge Assist 2, 3, 4 & 5 Tons PUB. NO. 22-1826-01 Features and Benefits Two Climatuff compressors Efficiency

More information

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems Universal Split Systems If there is a fault on any LG Universal unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the fault will

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF ASU5RLS AOU 9RLFW AOURLFW AOU5RLS R40A CONTENTS. DESCRIPTION OF EACH CONTROL

More information

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp

More information

Air Conditioning for Small and Medium-size Buildings

Air Conditioning for Small and Medium-size Buildings Air Conditioning for Small and Medium-size Buildings Defining a HIGHER standard The all-new MiNi-SMMS air conditioner lineup lets you cool or warm as many as 12 *1 rooms with a single system. Outdoor units

More information

SiBE12-625. D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump

SiBE12-625. D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump SiBE12-625 D-Series / E-Series [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump SUPER MULTI NX D-Series / E-Series Cooling Only Indoor Unit FTKS20D3VMW FTKS20CAVMB FDKS25CAVMB

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CM97 CM7 CM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No. CM97

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402 TECHNICAL & SERVICE MANUAL SA 79G SA 99G FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-79G-A 1 851 005 18 General (50Hz) & Europe SA-99G-A 1 851 005 19 SA 79G SA 99G REFERENCE

More information

catalog Single Package Vertical Air Conditioners and Heat Pumps

catalog Single Package Vertical Air Conditioners and Heat Pumps catalog Single Package Vertical Air Conditioners and Heat Pumps Catalog: SK145.00-EG1 (1008) TABLE OF CONTENTS Single Package Vertical Units Introduction...............................................................................

More information

14. Troubleshooting Guide

14. Troubleshooting Guide 14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include

More information

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner

More information

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,

More information

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS NOR-LAKE, INCORPORATED 727 Second Street P.O. Box 248 Hudson, Wisconsin 54016 800-955-5253 715-386-2323 866-961-5253 Parts 800-388-5253 Service 715-386-4291 FAX www.norlake.com Split-Pak Pre-Assembled

More information

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW -

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW - AIR-COOLED CHILLERS APPLIED SYSTEMS www.daikin.eu Cooling Only Heat pump EUWA*5-24KAZW - EUWY*5-24KAZW - Environmental Awareness Daikin and the Environment In recent years, motivated by a global awareness

More information

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety

More information

Operating Instructions Split System Air Conditioner

Operating Instructions Split System Air Conditioner Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This

More information

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER ( Split system, air to air heat pump type )

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER ( Split system, air to air heat pump type ) Manual No. 06. SRK-T. 050 updated September 29, 2009 INVERTER WALL MOUNTED TYPE ROOM AIR-CDITIER ( Split system, air to air heat pump type ) SRK20ZD-S1, SRK25ZD-S1, SRK35ZD-S1, SRK50ZD-S1 SRK63ZE-S1, SRK71ZE-S1

More information

How To Measure Temperature On A Thermostat

How To Measure Temperature On A Thermostat Кондиционеры Mitsubishi Heavy Техническое руководство Кондиционеры настенного типа SRK20HD-S, SRK28HD-S, SRK40HD-S, SRK20CD-S, SRK28CD-S, SRK40CD-S CTENTS 1. GENERAL INFORMATI... 1 1.1 Specific features...

More information

DUCTED AIR CONDITIONING SOLUTIONS

DUCTED AIR CONDITIONING SOLUTIONS DUCTED AIR CONDITIONING SOLUTIONS H I G H E N E R G Y E F F I C I E N C Y B A C K E D B Y A 5 Y E A R F U L L P A R T S & L A B O U R W A R R A N T Y DUCTED RANGE WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE

More information

Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain Ship. Wt. Lbs.

Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain Ship. Wt. Lbs. COMPACT UNIT FOR CEILING OR WALL MOUNT Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain. MJ-40 400 600 7 13 5/8 8 125 5 1/4" 0.65 0.35

More information

Technical data UNIBLOCK UBSF 180 625

Technical data UNIBLOCK UBSF 180 625 Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power

More information

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0 Air Conditioner Service Manual 2 3 Model: AC-S13CG x 2 3 Content Technical specification.. 4 Performance curve.5 Outline & dimension of indoor unit..10 Outline & dimension of outdoor unit 11 Exploded view

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

SERVICE MANUAL MUZ-FE09NA MUZ-FE12NA MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-A. Models HFC

SERVICE MANUAL MUZ-FE09NA MUZ-FE12NA MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-A. Models HFC SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FE18NA has been added. Please void OBH543. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH543 REVISED EDITION-A Models MUZ-FE09NA MUZ-FE12NA MUZ-FE18NA Indoor

More information

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR (For NEW 2007 ALL WHITE KWIK-KITS ONLY) Warning do not attempt to install A/C units unless you are experienced with servicing

More information

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and

More information

Air conditioners Heating & Cooling

Air conditioners Heating & Cooling Air conditioners Heating & Cooling Replacement VRV Cost effective upgrade for R-22 s High efficiency Possibility to increase capacity Limited and planned downtime Limited and phased investment cost www.daikin.eu

More information

Local Dealer: www.cebrands.com

Local Dealer: www.cebrands.com Local Dealer: C.E. LLC - Miami, FL USA www.cebrands.com Res2012-Rev2 QUALITY YOU CAN FEEL Residential Product Line >TCA7,9 Tempstar SmartComfort TXT + Air Conditioner Featuring The Observer Communication

More information

AIR CONDITIONER OUTDOOR UNIT. 1. Precautions. 2. Product Specifications. 3. Disassembly and Reassembly. 4. Troubleshooting

AIR CONDITIONER OUTDOOR UNIT. 1. Precautions. 2. Product Specifications. 3. Disassembly and Reassembly. 4. Troubleshooting SYSTEM AIR CONDITIONER OUTDOOR UNIT AIR CONDITIONER CONTENTS 1. Precautions 2. Product Specifications 3. Disassembly and Reassembly 4. Troubleshooting 5. PCB Diagram and Parts List 6. Wiring Diagram 7.

More information

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 Technical Specifications Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 For chiller storage of all sorts of items Chiller storage temperature: 2-5 C Provides excellent thermal efficiency

More information

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None 1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements

More information

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE

More information

How To Power A Car With A Fan And A Fan (Power)

How To Power A Car With A Fan And A Fan (Power) SPLIT TYPE ROO AIR CONDITIONER CEILING WALL TYPE INVERTER Indoor unit AWYZLBC AWYZLBC AWYZLBC AWYZLBC Outdoor unit AOYZLBC AOYZLBL AOYZLBC AOYZLBL CONTENTS SPECIFICATIONS................... OUTLINE AND

More information

Engineering Specifications

Engineering Specifications Engineering Specifications NORDIC W-85-H-B-*S-PD Water to Water Heat Pump Single-Stage R134a Nominal 7.5 Ton With Double Wall Condenser for Domestic Hot Water Production Maritime Geothermal Ltd. P.O. Box

More information

Multi Air Conditioner SVC MANUAL(Exploded View)

Multi Air Conditioner SVC MANUAL(Exploded View) Internal Use nly http://biz.lgservice.com Multi Air Conditioner SVC MANUAL(Exploded View) MDEL : A5UW306FA3 CAUTIN Before Servicing the unit, read the safety precautions in Standard SVC manual. nly for

More information

CoolTeg Plus Chilled Water (CW) version: AC-TCW

CoolTeg Plus Chilled Water (CW) version: AC-TCW version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420

More information

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER

More information

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History

More information

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting

More information

PANASONIC TROUBLE SHOOTING GUIDE

PANASONIC TROUBLE SHOOTING GUIDE A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling

More information

Versati Air to Water Heat Pump

Versati Air to Water Heat Pump Versati Air to Water Heat Pump VERSATI DC Inverter Multifunctional Air To Water Heat Pump Nowadays, people are increasingly focusing on heating costs as well as environmental issues. Traditional heating

More information

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data 4TTB3018-060 1½ 5 Tons PUB. NO. 22-1843-14 Features and Benefits Efficiency up to 13.25 SEER All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, easy

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information