Molded Case Circuit Breakers
|
|
- Daniela Stephens
- 7 years ago
- Views:
Transcription
1 Specifications Molded Case Circuit Breakers TD/TS series circuit breakers have built in thermal-magnetic trip units. Some models of the TD/TS series circuit breakers are UL Listed to be applied at up to 100% of their current rating. Because of the additional heat generated, the use of specificallydesigned enclosures and 90 C rated wire are required when using circuit breakers at 100% of their current rating. Markings on the circuit breaker indicate the minimum enclosure size and ventilation requirements. The 90 C wire size shall be based on UL 489. Circuit breakers with 100% rating can also be used in applications requiring only 80% continuous loading. Molded Case Circuit Breakers TD/TS Series Frame size Rated current ln Number of poles Rated operational voltage, Ue AC UL interupting rating 120V 240V AC 50/60Hz 480V 600V Reference standard Available breaker types Accessories Mechanical life Electrical AC Weight 3-pole lbs (kg) Basic dimension, Wx Hx D 3-Pole in (mm) A V ka Operations Operations TD AF 15, 20, 30, 40, 50, 60, 80, 100, NU HU UL 489 Fixed thermal, fixed magnetic FTU Adjustable-thermal, fixed-magnetic FMU - AX - Auxiliary switch AL - Alarm switch SHT - Shunt trip UVT - Undervoltage trip EHU - Extended rotary handle FH - Flange handle PL, PHL - Locking devices (Removable, fixed) MIT - Mechanical interlock device 4,000 4, lbs (1.2kg) 3.54 x 6.46 x 3.39in (90 x 164 x 86mm)
2 Specifications TS250 TS400 TS AF 400AF 800AF 150, 175, 200, , , 600, NU HU NU HU NU HU UL489 Fixed thermal, fixed magnetic, FTU Fixed thermal, fixed magnetic, FTU Fixed thermal, fixed magnetic, FTU Adjustable-thermal, fixed-magnetic, FMU Adjustable-thermal, fixed-magnetic, FMU Adjustable-thermal, fixed-magnetic, FMU Adjustable-thermal, Adjustable-magnetic (3 pole), ATU Adjustable-thermal, Adjustable-magnetic (3 pole), ATU Adjustable-thermal, Adjustable-magnetic (3 pole), ATU AX - Auxiliary switch AX - Auxiliary switch AX - Auxiliary switch AL - Alarm switch AL - Alarm switch AL - Alarm switch SHT - Shunt trip SHT - Shunt trip SHT - Shunt trip UVT - Undervoltage trip UVT - Undervoltage trip UVT - Undervoltage trip EHU - Extended rotary handle EHU - Extended rotary handle EHU - Extended rotary handle FH - Flange handle FH - Flange handle FH - Flange handle PL, PHL - Locking devices (removable, fixed) PL, PHL - Locking devices (removable, fixed) PL, PHL - Locking devices (removable, fixed) MIT - Mechanical interlock device MIT - Mechanical interlock device MIT - Mechanical interlock device 5,000 5,000 3,000 1,000 1, lbs (1.9kg) 12.57lbs (5.7kg) 29.98lbs (13.6kg) 4.13 x 7.01 x 3.39in (105 x 178 x 86mm) 5.51 x x 4.33in (140 x 292 x 110mm) 8.27 x x 5.31in (210 x 428 x 135mm)
3 Ordering Information TD/TS Series Circuit Breakers (FTU) UL Interrupting Rating (ka) Frame Amp Size Rating 240V 480V 600V NU HU NU HU NU HU 125AF 250AF 400AF 800AF 15A Magnetic Trip Setting HU Series (High Interrupting) TD125HU FTU A NU Series (Normal Interrupting) TD125NU FTU A 20A TD125HU FTU A TD125NU FTU A 30A TD125HU FTU A TD125NU FTU A 40A TD125HU FTU A TD125NU FTU A 50A X TD125HU FTU A TD125NU FTU A 60A TD125HU FTU A TD125NU FTU A 80A TD125HU FTU A TD125NU FTU A 100A TD125HU FTU A TD125NU FTU A 125A TD125HU FTU A TD125NU FTU A 150A TS250HU FTU A TS250NU FTU A 200A X TS250HU FTU A TS250NU FTU A 250A TS250HU FTU A TS250NU FTU A 300A TS400HU FTU A TS400NU FTU A X 400A TS400HU FTU A TS400NU FTU A 500A TS800HU FTU A TS800NU FTU A 600A X TS800HU FTU A TS800NU FTU A 800A TS800HU FTU A TS800NU FTU A TD/TS Series Circuit Breakers (FMU) UL Interrupting Rating (ka) Frame Amp Size Rating 240V 480V 600V NU HU NU HU NU HU 125AF 250AF 400AF 800AF 40A Magnetic Trip Setting HU Series (High Interrupting) TD125HU FMU A NU Series (Normal Interrupting) TD125NU FMU A 50A TD125HU FMU A TD125NU FMU A 60A TD125HU FMU A TD125NU FMU A X 80A TD125HU FMU A TD125NU FMU A 100A TD125HU FMU A TD125NU FMU A 125A TD125HU FMU A TD125NU FMU A 150A TS250HU FMU A TS250NU FMU A 200A X TS250HU FMU A TS250NU FMU A 250A TS250HU FMU A TS250NU FMU A 300A TS400HU FMU A TS400NU FMU A X 400A TS400HU FMU A TS400NU FMU A 500A TS800HU FMU A TS800NU FMU A 600A X TS800HU FMU A TS800NU FMU A 800A TS800HU FMU A TS800NU FMU A TD/TS Series Circuit Breakers (ATU) UL Interrupting Rating (ka) Frame Amp Size Rating 240V 480V 600V NU HU NU HU NU HU 250AF 400AF 800AF 150A Magnetic Trip Setting HU Series (High Interrupting) TS250HU ATU A NU Series (Normal Interrupting) TS250NU ATU A 200A X TS250HU ATU A TS250NU ATU A 250A TS250HU ATU A TS250NU ATU A 300A TS400HU ATU A TS400NU ATU A X 400A TS400HU ATU A TS400NU ATU A 500A TS800HU ATU A TS800NU ATU A 600A X TS800HU ATU A TS800NU ATU A 800A TS800HU ATU A TS800NU ATU A
4 Technical Information Application Circuit Breakers for 400Hz Networks When circuit breakers are used at high frequencies, the breakers are required to be derated due to increased resistance of the copper sections resulting from the skin effect produced by eddy currents at 400Hz. Standard production breakers can be used with alternating currents with frequencies other than 50/60Hz when appropriate derating coefficients should be applied. Thermal Magnetic Trip Thermal trip: From the data shown below, the tripping threshold of the thermal element (ln) decreases as the frequency increases because of the reduced conductivity of the materials and the increase of the associated thermal phenomena. Rated current (A) at 400Hz= K1x rated current (A) at 50/60Hz. Instantaneous trip: The magnetic threshold increases with the increase in frequency. Instantaneous current (A) AT 400Hz= 2x Instantaneous current (A) at 50/60Hz Thermal Magnetic Trip Units TD and TS Series Performance Table at 400Hz Rated current (A) In at 400Hz MCCB MCCB Style K1 (Thermal trip units) Multiplier factors (K1, K2) K2 (Magnetic trip units) TD125NU, TD125HU FTU FMU TS250NU, TS250HU FTU 300 FMU 350 TS400NU,TS400HU ATU TS800NU, TS800HU *K1x multiplier factor of rated current (ln) K2-multiplier factor of instantaneous current due to the induced magnetic fields FTU-Fixed Thermal and magnetic trip unit FMUx-Adjustable thermal and fixed magnetic trip unit ATUx-Adjustable thermal and magnetic trip unit
5 BREAKER BO NEMA 3R Enclosed Circuit Breaker AF NEMA Rated Enclosed Breaker for Harsh Environments Simplified product range AF: 125, 250, 400, 800 Ampere range: 15A ~ 800A Superior technology results in high performance Cerus TD and TS circuit breakers provide superior performance in a compact package, with adjustable thermal trip settings and magnetic trip settings for ultimate flexibility Advanced arc quenching technology ensures excellent trip performance and long life Standardized internal accessories are interchangeable on all models and are field or factory installed Accessories mount on right or left side to simplify panel wiring Perfect for main disconnect applications Variable accessories Common use of electrical auxiliaries Motor operator Plug-in kit Terminals Communication module Cerus support & service Live tech support Made in USA Same day shipping 5 year warranty World class customer service High Interrupting Capacity TS800HU TS400HU TS250HU TD125HU TD125NU TS800NU TS400NU TS250NU Rated current (A) 800A 400A 250A 125A
6 Ordering Information *Please refer to page 92 for Molded Case Circuit Breaker part numbers TD/TS Series Accessories Alarm & Auxiliary Switches Description Alarm Switch for TD/TS Series MCCB Auxiliary Switch for TD/TS Series MCCB Part Number AL-TD/TS AX-TD/TS Under Voltage Trip, UVT Control Voltage AC/DC 24V AC/DC 48V AC/DC 110~130V AC/DC 200~240V/DC 250V AC/DC 380~440v AC/DC 440~480v Part Number UVT-24V UVT-48V UVT-120V UVT-230V UVT-400V UVT-480V Shunt Trip, SHT Control Voltage DC 12V AC/DC 24V AC/DC 48V AC/DC 110~130V AC/DC 220~240V/DC250V AC/DC 380~500V Part Number SHT-12VDC SHT-120V SHT-230V SHT-24V SHT-48V SHT-480V Enclosures AF 125AF 250AF 400AF 800AF Part Number CER1-TD125CB-ENCL CER1-TS250CB-ENCL CER1-TS400CB-ENCL CER1-TS800CB-ENCL
7 Breaker Box Dimensions CER1-TD125CB-ENCL MTG MTG FRONT VIEW RIGHT VIEW BACK VIEW Ø1.750 KNOCKOUT (x2) Ø1.125 KNOCKOUT (x2) BOTTOM VIEW CER1-TS250CB-ENCL MTG MTG FRONT VIEW SCALE 1/5 Ø.250 LOCKOUT Ø2.500 KNOCKOUT (x2) RIGHT VIEW SCALE 1/5 BACK VIEW SCALE 1/5 Ø1.500 KNOCKOUT (x2) BOTTOM VIEW SCALE 1/
8 Breaker Box Dimensions CER1-TS400CB-ENCL 8 3/4 6 1/2 MTG. 3/8 THRU 37 1/16 OD 25 MTG. FRONT VIEW RIGHT VIEW BACK VIEW 11 11/16 OD BOTTOM VIEW CER1-TS800CB-ENCL MTG MTG. FRONT VIEW RIGHT VIEW BACK VIEW BOTTOM VIEW
NEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION. Super Solution
NEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION Super Solution Low voltage circuit breakers Susol LV circuit breakers Super Solution Contents Overview Electrical characteristics Trip units Accessories
More informationGeneral information Circuit breakers for power distribution T1 T3
Circuit breakers for power distribution T1 T3 T1 T2 T3 T1 1P T1 T2 T3 UL 489 CSA C22.2 Frame size A 100 100 100 225 Number of poles Nr 1 3, 4 3, 4 3, 4 Rated voltage AC (50-60 Hz) V 277 600Y / 347V 480
More informationTmax MCCBs. Molded case circuit breakers. Tmax
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
More informationCircuit Breakers. Next Generation of Protection Capabilities
Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many
More informationMolded case circuit breakers
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high
More information8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
More informationLow voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
More informationSUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according
More informationDecision-Maker Paralleling System. Power Distribution Switchboards and Circuit Breakers. Standard Features
Decision-Maker Paralleling System Power Distribution Switchboards and Circuit Breakers Power Distribution Switchboards and Circuit Breakers The generator paralleling circuit breakers for the Kohler Decision-Maker
More informationDimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140)
9-10N Supersedes Selection Data 9-10N, pages, 1-, dated dated March March 1995 1995 Mailed to: E, D, C/9-100A, 31-A, INTERRUPTING CAPACITY RATINGS IEC 947- Interrupting Capacity s➀ Interrupting Capacity
More informationPRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2
More informationNM8, NM8S NM8, NM8S. Moulded Case Circuit Breakers. 3. Type designation. 4. Product overview N M 8 / / /
Moulded Case Circuit Breakers NM8, NM8S 3. Type designation 4. Product overview N M 8 / / / NM8 Moulded Case Circuit Breaker Application code Blank: for power distribution; NM8, NM8S Moulded Case Circuit
More informationVL circuit breakers. Information guide. www.usa.siemens.com/circuitbreakers
VL circuit breakers Information guide www.usa.siemens.com/circuitbreakers Table of contents Technical data 2 8 DG 150A frame 9 14 FG 250A frame 15 20 JG 400A frame 21 26 LG 600A frame 27 32 MG 800A frame
More informationMolded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data
Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors Technical Data Table of Contents Introduction... 4 Definitions... 5 Product Range... 8 Product Line Overview...11
More informationSentron Series Circuit Breakers
Sentron Series Circuit Breakers Siemens Sentron Series circuit breakers are available in nine frame sizes: ED, FD, JD, LD, LMD, MD, ND, PD, and RD. Sentron Series circuit breakers have a wide range of
More informationSubmit shop drawings for equipment provided under this section Shop drawings shall indicate:
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,
More informationBulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
More informationBussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1
How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module
More informationTmax. Molded case circuit breakers. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com. Tmax.
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
More informationLow Voltage Disconnect Switches. NFPA79 and UL508A Industrial Machinery Operating Handle Requirements White Paper
Low Voltage Disconnect Switches NFPA79 and UL508A Industrial Machinery Operating Handle Requirements White Paper Scope This document is intended to discuss the functional requirements for the disconnecting
More informationMolded Case Circuit Breaker Specifications Bulletin Number 140U-D
Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents
More informationThermal-Magnetic / Magnetic Only Molded Case Circuit Breakers
Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Catalog 2004 Class 601 CONTENTS Description..............................................Page INTRODUCTION.............................................
More informationCircuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services
Circuit Breakers and Switchgear Thomas Greer Director of Engineering TLG Services Presentation Outline Switchgear Definition Overcurrent Protection Devices Circuit Breaker Trip Curves and Coordination
More informationThermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
More informationELFA MINIATURE CIRCUIT BREAKERS
ELFA MINIATURE CIRCUIT BREAKERS Standard Accesories CATALOG NO. ITEM LIST M ELFA-714 3 Phase Bus connection $101.00 39 inches (1000 mm) M ELFA-085 Protective Cap for Finger Safe $ 1.70 M ELFA-760 Bus Bar
More informationSecondary Unit Substations
14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically
More informationMining service breakers with true rms sensing designed specifically for trailing cable applications
Eaton Mining Service Circuit Breakers E 2 Series 15 2000 Amperes 600 and 1000 Vac Mining service breakers with true rms sensing designed specifically for trailing cable applications E 2 mining service
More informationCatalog January. Heavy industrial power applications Motor contactors and starters
Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type
More informationDistribution Dry Type Transformers
8 TRASFORMERS Distribution Dry Type Transformers Table (Contact Sales office for List Price) (commonly used) 1a. 115 C Rise F 1b. 80 C Rise B 4. Wall Brackets1 W 6. Low noise XdB below std. LX Type bg
More informationMetallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features
Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case
More informationAlternate Methods to Short Circuit Breaker Coordination
Alternate Methods to Short Circuit Breaker Coordination Nguyen Perez, PE Senior Electrical Engineer 2600 Douglas Road, Suite 301 Coral Gables, Florida 305.529.1515 (p) www.brplusa.com Importance in Healthcare
More informationManual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
More informationBulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable
More informationLow Voltage Products. Switches Automatic Transfer Switches
Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. High energy prices,
More informationIndex. 17 - Molded case circuit breakers. Molded case circuit breakers. Tmax UL489B Photovoltaic circuit breakers...17.67-17.70
Molded case circuit breakers Index Molded case circuit breakers - Molded case circuit breakers Formula...1 -.10 General information Introduction...1 Circuit breakers for power distribution...2 explanation...3
More informationHow To Operate A Gec Transfer Switch Open Transition 40 2000 Amp Power Supply
GTEC Transfer switch open transition 40 2000 amp Description GTEC transfer switches combine reliability and flexibility in a small, economical package for transferring loads between a utility and a generator
More informationSENTRON Switching and Protection Devices Air Circuit Breakers
Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General
More informationGTEC transfer switch open transition
GTEC transfer switch open transition 40-1250 Amp Description The GTEC automatic transfer switch combines reliability and flexibility in a small, economical package for transferring loads between a utility
More informationPSR The compact range Description
Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides
More informationPrimary and Secondary Electrical Distribution Systems
Primary and Secondary Electrical Distribution Systems Critical Facilities Round Table 12th Quarterly Membership Meeting June 2, 2006 David D. Roybal. P.E. Eaton Electrical Cutler-Hammer Products Utility
More informationSUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches
SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More informationA sophisticated design for a demanding field. prima series
A sophisticated design for a demanding field prima series 2 nd edition 2003 prima compact horizontal interlocked sockets carefully studied A size for all versions with or without fuses. Extends horizontally
More informationCIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS
CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS David D. Roybal, P.E. Senior Member, IEEE Eaton Electrical 3697 Mount Diablo Boulevard Lafayette, CA 94549 Abstract Low-voltage circuit
More informationElectronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600
Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600 Data Bulletin 0600DB1104 03/2012 Retain for future use. Electronic Trip Circuit Breaker Basics 0600DB1104 Table of Contents
More informationMining service breakers with true rms sensing designed specifically for trailing cable applications
Eaton mining service circuit breakers E 2 Series 15 2000 Amperes 600 and 1000 Vac Mining service breakers with true rms sensing designed specifically for trailing cable applications E 2 mining service
More informationMotor circuit-breakers
Thermal-magnetic motor circuit-breakers type GV2-M GV2-M Thermal-magnetic motor circuit-breakers GV2-M Pushbutton control Standard power ratings Setting Magnetic Thermal Reference Weight of 3-phase motors
More informationPREFACE. The products covered by this Guide are:
PREFACE UL has developed the Molded-Case Circuit Breaker (MCCB) Marking Guide for code authorities, electric utilities, contractors, installers, users, designers, and other interested parties to aid in
More informationManual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
More informationConnecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations
Connecting the Power of the Sun DC Disconnects for Solar Photovoltaic Installations DC disconnects for solar photovoltaic installations Solar energy is heating up Interest in renewable energy sources has
More informationSIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.
The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved
More informationSECTION 26 29 23 VARIABLE FREQUENCY DRIVES
SECTION 26 29 23 VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 SCOPE A. Furnish and install individual freestanding variable frequency AC drives (VFD) as shown on the Drawings and specified herein. 1.02
More informationHPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80
Buck-Boost Transformers Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...
More informationRotary Disconnect Switch Specifications
Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources
More informationTransfer switch BTPC open, closed or delayed transition
Transfer switch BTPC open, closed or delayed transition 150-4000 Amp Description The Cummins Power Generation BTPC series bypass isolation transfer switch combines an automatic transfer switch with a drawout
More informationMCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
More informationHow To Test A Power Switch On A Power Supply
transfer switches Soft load Innovative, reliable, integrated solution Built with years of experience Powered with innovation Delivered with reliability A history of experience, innovation and reliability
More informationAUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL
ATS-220 AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL For Use in 208 to 240 Volts Single and 3 Phase ATS Systems With 110Volt AC or DC Control Motors and selenoids 4501 NW 27 ave Miami FL 33142
More informationLow and Medium Voltage Division Erlangen, February 18, 2014. New MCCBs for Increased Line Protection and Availability
Infrastructure & Cities Sector Press Low and Medium Voltage Division Erlangen, February 18, 2014 Hannover Messe 2014, hall 9, booth D35 New MCCBs for Increased Line Protection and Availability The 3VA
More informationBT300 HVAC Drives Conventional Bypass (C-Bypass) Options
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC
More informationDead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms
Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms ABB innovations for changing demands ABB (www.abb.com) is a leader in power and automation technologies that enables utility
More informationDoc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC
TM 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM D400E Data Module (60Hz) The EDGE D400E is designed to meet high power density requirements for both the HPC and Web Scale environments while
More informationCAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a
More informationUNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation
Basis of Design This section applies to the design relating to low voltage switchboards. Design Criteria UW Class N1 facilities main switchboards shall be rear accessible. The main, tie and feeder breakers
More informationAC1645. System pro M compact Supplementary Protectors Miniature MCCBs
AC1645 System pro M compact Supplementary Protectors Miniature MCCBs Table of Content 1 2 3 4 5 pro M compact General information...1.1 S200 - Supplementary protectors...1.7 S200U - Miniature MCCBs...1.12
More informationData Bulletin. Circuit Breaker Characteristic Trip Curves and Coordination Class 0600 TRIP CURVES AND COORDINATION CIRCUIT BREAKER TRIP CURVES
Data Bulletin Bulletin No. 000DB0 August 0 Cedar Rapids, IA, USA Class 000 TRIP CURVES AND COORDINATION CIRCUIT BREAKER TRIP CURVES Thermal Tripping Characteristics agnetic Tripping Characteristics A coordination
More informationP 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.
This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product
More informationMODEL HSR-007 Direct Drive Rolling Steel
MODEL HSR-007 Direct Drive Rolling Steel 200 Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8 Tel: 866-792-9968 or 705-792-9968 Fax: 705-735-9564 www.tnrdoors.com email: info@tnrdoors.com Model HSR-007
More informationBulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
More informationABB Inc. April 19, 2011 Slide 1
ABB Automation & Power World: April 18-21, 2011 Allen Austin - Solar Segment Manager North America, Low Voltage Products WLP-123-1-CEU Solar applications for low voltage products ABB Inc. April 19, 2011
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationMini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional
More information26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
More informationBolted contact switches. Pringle switches
Bolted contact switches Pringle switches Eaton s Pringle bolted contact switches History Eaton s PringleT switches have helped pioneer the development of high-quality electrical products for commercial
More informationType: DILM9 10(24VDC) Article No.: 276705
Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
More informationPREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:
PREFACE UL has developed the Molded-Case Circuit Breaker (MCCB) Marking Guide for electrical inspectors, electric utilities, contractors, installers, users, designers, and other interested parties to aid
More informationTechnical catalog. FORMULA UL New low voltage molded case circuit breakers up to 250A. Power and productivity for a better world TM
Technical catalog FORMULA UL New low voltage molded case circuit breakers up to 2A Power and productivity for a better world TM Index Main characteristics 1 Circuit breakers for power distribution 2 Accessories
More informationThe HVAC SOLUTION DELIVERING POWER...SAVING ENERGY
The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY PowerGate - Cost effective solutions for F 1 Horsepower Rating 001 1-40 HP (208V) 075 1-75 HP (480V) Input Voltage 2V 208-240V 4V 380-480V Disconnect
More informationQUICK REFERENCE PRICE GUIDE JULY 2015
QUICK REFERENCE PRICE GUIDE JULY 2015 ISO 9001: 2008 OUR CUSTOMER CARE COMMITMENTS Quality is Guaranteed All products supplied from this Quick Price Guide carry a guarantee against defects in materials
More informationData Bulletin. Choosing a Trip Unit for PowerPact H-, J-, and L-Frame Circuit Breakers. Introduction. Thermal-Magnetic or Electronic Trip Unit?
Data Bulletin 011DB110 07/01 Choosing a Trip Unit for PowerPact H-, J-, and L-Frame Circuit Breakers ENGLISH Inoduction Thermal-Magnetic or Eleconic Trip Unit? Thermal-Magnetic Trip Units 01171 t 0119
More informationDC disconnects for solar photovoltaic installations. Connecting the. power of the sun
DC disconnects for solar photovoltaic installations Connecting the power of the sun Solar energy is heating up Interest in renewable energy sources has never been greater, and the fastest growing of these
More information3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold 41-759.3C
41-759.3C the magnetic core upon energizing of the switch. When the switch closes, the moving contacts bridge two stationary contacts, completing the trip circuit. Also during this operation two fingers
More informationSmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial
SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU5000RT4UHV Description Tripp Lite SU5000RT4UHV 5000VA / 5kVA /
More informationTechnical catalog - Edition 2015. SACE Tmax PV Adaptability, versatility and complete freedom continue
Technical catalog - Edition 205 SCE Tmax PV daptability, versatility and complete freedom continue SCE Tmax PV automatic molded case circuit-breakers and molded case switch-disconnectors The Tmax PV line
More informationP70, P72, and P170 Series Controls for Dual Pressure Applications
P70, P72, and P170 Series Controls for Dual Pressure Applications Product Bulletin Code No. LIT-125455 Issued August 30, 2012 Supersedes September 1, 2000 The P70, P72, and P170 controls for dual pressure
More informationPhone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC
More informationINSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
More information32VFD Variable Frequency Drives for Centrifugal Chillers
32VFD 32VFD Variable Frequency Drives for Centrifugal Chillers ENERGY-SAVING CONTROL FOR CENTRIFUGAL CHILLERS Reduce energy consumption in your existing centrifugal chiller Your chiller was specified to
More informationMTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation
MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability
More informationFundamentals of Power
Fundamentals of Power Fundamentals of Power 2008 American Power Conversion Corporation. All rights reserved. All trademarks provided are the property of their respective owners. Learning Objectives At
More informationFigure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.
Crydom RHP Series 3 Phase Hybrid Solid State Contactor By Paul Bachman Fellow Engineer, Crydom, Inc. ABSTRACT Solid State Relays and Contactors (SSRs) have been available in one form or the other for over
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationThe complete range of consumer switchboards and switchgear
Power Distribution The complete range of consumer switchboards and switchgear www.nhp.com.au/mod6 The MOD6 range of consumer switchboards and switchgear is specifically designed for domestic and commercial
More informationAP/UP, AP/MIL Series. Magnetic Circuit Protectors
AP/UP, AP/MIL Series Magnetic Circuit Protectors Introduction Poles Configurations Operating Characteristics Delay Curves Specifications Decision Tables 71 72 75 76 77 78 79 AP/UP, AP/MIL Series Hydraulic
More informationPowerFlex 700 and 700H Packaged Drives. Technical Data
PowerFlex 700 and 700H Packaged Drives Technical Data Overview The heart of every PowerFlex 700/700H packaged drive package is a PowerFlex Adjustable Frequency Drive. The packaged drives program provides
More informationElectrical auxiliaries 0 For i DPN (DPN), C60 and C120
Circuit protection For i DPN (DPN), C60 and C120 Function They remotely trip or indicate circuit-breakers, with or without Vigi module. Description b They are mounted to the left of the circuit-breaker
More informationOperation and Maintenance manual. fusible shunt trip switch
Operation and Maintenance manual fusible shunt trip switch Table of Contents Fusible Shunt Trip Switch Device Overview... 2 Installation Instructions... 3 Catalog Number Selection Table... 4 Motor Fuse
More informationSelf Monitoring Power Supply (BPSM)
LIFETIME REPLACEMENT WARRANTY Self Monitoring Power Supply (BPSM) Application - When interfacing with a fire alarm system where the system s auxiliary relay cannot handle the full current potential of
More informationASCO SERIES 185 Power Transfer Switches
ASCO SERIES 185 Power Transfer Switches 4-hour protection no matter when trouble strikes ASCO Series 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... Your business or home from
More informationNew SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager
New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager 2 1SDC200039B0201 New SACE Emax 2 for UL 1066 Circuit breakers switch power SACE Emax 2 manages it. SACE Emax 2 is the new benchmark of
More information