1 K1MICROBEAD MAN UK English INSTALLATION AND INSTRUCTION MANUAL PLEASE READ INSTALLATION INSTRUCTIONS THOROUGHLY BEFORE INSTALLATION. PLEASE NOTE: Do not operate the multi-port valve with the circulating pump switched on. The ball valve on the air blower line must be closed when the circulating pump is switched on. Evolution Aqua Ltd. - Evolution House - Kellet Close - Wigan - Lancashire - United Kingdom - WN5 0LP t +44 (0) f +44 (0) e [email protected] - w
2 INTRODUCING THE K1 MICRO BEAD FILTER SYSTEM Congratulations on purchasing an Evolution Aqua K1 Micro Bead Filter system. The K1 Micro Bead Filter systems are a range of pressurised systems that deliver incredible levels of filtration for ponds. By using the new K1 Micro filter media instead of conventional beads, these filters offer better mechanical filtration along with unparalleled biological filtration. This is due to the vast PROTECTED SURFACE AREA of K1 Micro filter media. The media also improves flow through the filter meaning lower energy pumps can be used. This protected surface area safely houses friendly filter bacteria and prevents them from being flushed to waste during the cleaning cycle. This results in better nitrification. The K1 Micro Bead Filter has been designed to allow improved flow of water through the unit meaning a lower wattage pump can be used saving you money. All in all, the K1 Micro Bead Filters offer unsurpassed mechanical filtration, tremendous biological performance, saves you money and can be installed on any type of installation. Please read this instruction manual carefully from start to finish before attempting to install your new K1 Micro Bead Filter. 2
3 CONTENTS K1 Micro Bead Filter parts list PAGE 4 Specifications PAGE 5 K1 Micro Bead Filter dimensions PAGE 6 How the K1 Micro Bead Filter works PAGE 8 The Multi-Port Valve PAGE 9 K1 Micro Bead Filter installations PAGE 10 K1 Micro Bead Filter installation instructions PAGE 11 K1 Micro Bead Filter cleaning instructions PAGE 12 Quick cleaning / backwash instructions PAGE 13 How to get the best from your K1 Micro Bead Filter PAGE 13 Winter Maintenance PAGE 14 Troubleshooting PAGE 15 Warranty PAGE 16 Warranty Card PAGE 17 3
4 K1 MICRO BEAD FILTER PARTS LIST Your K1 Micro Bead Filter comes complete with the following items: 1) K1 MICRO BEAD FILTER (Including lid and collar) 2) MULTI-PORT VALVE + BALL VALVE + FITTINGS 20 model supplied with 1½ MPV. 24, 30 and 36 models supplied with 2 MPV. 3) AIR BLOWER 20 and 24 models supplied with 200W Air Blower. 30 and 36 models supplied with 300W Air Blower. 4) PRESSURE GAUGE 5) DRAIN VALVE 5) AIR PRESSURE RELEASE VALVES 4
5 K1 MICRO BEAD FILTER SPECIFICATIONS MODEL NO. K1MICROBEAD20 K1MICROBEAD24 K1MICROBEAD30 K1MICROBEAD36 Diameter Volume of K1 Micro Media Multi-Port Valve size Maximum pond size 50 Litres 100 Litres 150 Litres 250 Litres 1½ ,000 UK Gallons 8,000 UK Gallons 12,000 UK Gallons 20,000 UK Gallons 18,000 Litres 36,000 Litres 54,500 Litres 91,000 Litres 4,800 US Gallons 9,600 US Gallons 14,500 US Gallons 24,000 US Gallons The maximum working pressure of all K1 Micro Bead Filters is 2.5 Bar. AIR BLOWER SIZE K1 MICRO BEAD 20 FILTER (20 ) = 200W Air Blower K1 MICRO BEAD 24 FILTER (24 ) = 200W Air Blower K1 MICRO BEAD 30 FILTER (30 ) = 300W Air Blower K1 MICRO BEAD 36 FILTER (36 ) = 300W Air Blower BALL VALVE FITTED BELOW THE AIR BLOWER On the pipe run between the MPV and the Air Blower there is a 1½ ball valve fitted. Figure 1a. IMPORTANT PLEASE READ The ball valve handle must always be closed when the circulating pump is switched on. This indicates that the ball valve is CLOSED. This is designed to prevent water flowing back into the air blower. Only open the ball valve when the pump is switched off and before operating the air blower. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY INVALIDATE THE WARRANTY. AIR BLOWER Figure 1b BALL VALVE CLOSED POSITION 5
6 DIMENSIONS Please allow an additional 15mm in length if you are installing a pressure gauge. K1 MICRO BEAD 20 FILTER Figure 2. K1 MICRO BEAD 24 FILTER Figure 3. 6
7 DIMENSIONS Please allow an additional 15mm in length if you are installing a pressure gauge. K1 MICRO BEAD 30 FILTER Figure 4. K1 MICRO BEAD 36 FILTER Figure 5. 7
8 HOW THE K1 MICRO BEAD FILTER WORKS Water enters the filter from the pond into the multi-port valve (MPV) and is directed to the bottom of the unit. As the water is pumped through the K1 Micro Bead Filter, dirt, debris and waste are trapped by the K1 Micro and then the massive protected surface area housing the filter bacteria biologically breaks down the Ammonia and Nitrite into Nitrate. The filtered water is returned to the top of the unit through the multi-port valve and back to the return line flowing back into the pond. Figure 6a. MULTI-PORT VALVE AIR PRESSURE RELEASE VALVES INLET WASTE OUTLET (Rear of MPV) LID COLLAR K1 MICRO PRESSURE GAUGE AUTOMATIC AIR BLEED OUTLET DRAIN VALVE Figure 6b. AIR BLOWER AIR BLOWER BALL VALVE BALL VALVE SIGHT GLASS 8
9 THE MULTI-PORT VALVE The K1 Micro Bead Filter is operated by a multi-port valve. This multi-port valve functions by pushing down on the handle, turning it and relocating it into one of the operating positions shown on the multi-port valve (see figure 7). The valve must always be operated with the circulating pump switched OFF. The ball valve positioned below the air blower must be closed when the pump is running. Below we offer an explanation of each of the multi-port valve s functions: close waste backwash filter recirculate rinse 1) FILTER: Incoming water from the pond enters the MPV at point (A) (see figure 8). The water enters the vessel at point (D) then flows upwards through the K1 Micro filter media to the top exit bar (B). The filtered water is returned through the multi-port valve at point (C) and back into the pond. A Figure 7. E WASTE OUTLET ON REAR OF MPV B 2) BACKWASH: This is the position the multi-port valve should be in for cleaning the K1 Micro filter media. With the valve in this position, water flow is reversed through the filter bed so that the water flow is directed to the top of the unit (B) and exits the unit at (D) and goes out to the waste line (E). 3) RINSE: This is the position the multi-port valve should be in for agitating the K1 Micro filter media. With the valve in this position, air (supplied by the air blower) is used to agitate the filter media. Later on in the cleaning process, water is used to rinse the K1 Micro and exit to waste (E). C Figure 8. D 4) WASTE: This is the position the multi-port valve should be in to allow water to by-pass the filter bed and drain to waste (E). With the multi-port valve in this position, the water flow is directed straight to waste by-passing the unit. This function can be used to lower the water level or for vacuuming your pond without soiling the filter. 5) RE-CIRCULATE: This is the position the multi-port valve should be in to allow water to completely by-pass the filter. With the valve in this position, water is pumped from the pond to the multi-port valve and directly back to the pond, without flowing through the K1 Micro Bead Filter. This is particularly handy if you are treating your pond. 6) CLOSED: This is the position the multi-port valve should be in for closing all flow to the filter. This position is not to be used with the pump running. Do not operate the multi-port valve with the circulating pump switched on. The ball valve must be closed when the circulating pump is running. 9
10 K1 MICRO BEAD FILTER INSTALLATIONS The K1 Micro Bead Filter is a versatile unit. It can be used: as a filter on its own in conjunction with a pre-filter on skimmer lines as a polisher at the end of a system on pump-fed systems on gravity fed systems installed at any height or location Here is a diagram showing a typical installation for a K1 Micro Bead Filter: Recommended Installation Air Blower Ball Valve UV CLARIFIER WATER LEVEL CETUS SIEVE INLET RETURN TO POND 2 Pipe* POND K1 MICRO BEAD FILTER 2 Pipe* 4 (110mm) Pipe Slide Valve NON RETURN VALVE PUMP Figure 9. The K1 Micro Bead Filter can be installed as shown above if you are planning to use a pre-filter such as the Evolution Aqua Cetus Sieve. If you are not planning to use a pre-filter we highly recommend that you fit a strainer basket to the pump. This will prevent leaves, string algae etc. from entering the filter and pump. 10 * It is recommended that all pipework on the pump side (from the pump to the filter and back to the pond) is installed on 2 pipe. Please note on the K1MicroBead20 Filter you will have to reduce your pipe down to 1½ to connect to the multi-port valve. This will ensure that your pump is working at its maximum flow. Do not operate the multi-port valve with the circulating pump switched on. The ball valve must be closed when the circulating pump is running.
11 K1 MICRO BEAD FILTER INSTALLATION INSTRUCTIONS We recommend following these instructions to install the K1 Micro Bead Filter. 1. Remove the K1 Micro Bead Filter, the multi-port valve, air blower, lid, collar, pressure gauge, air pressure release valves and drain plug from the box. (See page 4 for parts list). 2. Install the pressure gauge onto the multi-port valve as shown in figure 6a. 3. Screw the air pressure release valves onto the lid as shown in figure 6a. 4. Install drain valve as shown in figure 6a. 5. Position the filter as close as possible to the pond. IMPORTANT: The unit must be installed on a flat, level base, on firm ground or equivalent. Ensure the ground will not subside and strain pipework. We recommend using a flat solid concrete surface as a base for installation. Depending on the model of your K1 Micro Bead Filter the dimensions of this base will be different. Please see pages 7 and 8 for a full list of filter dimensions. 6. The filter should also be in a location that is free from flooding, is away from sumps, guttering, garden hollows and areas that may experience sub-zero conditions etc. 7. Allow room all the way around the K1 Micro Bead Filter to enable easy maintenance and servicing. Do not install the unit in a tight space. 8. Attach the multi-port valve and fittings ensuring the O-Rings are properly positioned. Hand tighten the unions only. The multi-port valve must not move during operation. 9. Make pipe connections onto the valve. Pump line (inlet), return line and waste lines are marked on the valve. A ball valve, slide valve or non-return valve needs to be installed on the pumps suction line from the pond / pre-filter to the pump. We highly recommend a non-return valve (see figure 9). Refer to your pump manufacturer s manual to see if the pump is self-priming. For the avoidance of doubt install your pump below the pond water level. Allow a full 24 hours for all glued pipework joints to harden. 10. Install a UV on the return line back to the pond. 11. Connect the air blower to the manifold (Figure 6b). Ensure the ball valve is attached, connected properly and the handle can be moved without restriction for cleaning. The air blower should be installed higher than the top of the filter. The air blower is only operated during the cleaning procedure. IMPORTANT: The ball valve must be in the CLOSED position when the circulating pump is running. 12. Pour the K1 Micro into the filter from the top. Then push the lid into position and hand tighten the collar. 13. Set the multi-port valve to the FILTER position. Turn on the pump and allow the unit to fill with water. Check for any leaks. Your K1 Micro Bead Filter will be operational. 14. When the unit is running, the biological side of the K1 Micro Bead Filter will take approximately 8 weeks to mature. We recommend adding PUREPOND to the unit to drastically speed up this process. See our top tips section on page 13. Do not operate the multi-port valve with the circulating pump switched on. The ball valve must be closed when the circulating pump is running. 11
12 K1 MICRO BEAD FILTER CLEANING INSTRUCTIONS Do not operate the multi-port valve with the circulating pump switched on. The ball valve must be closed when the circulating pump is running. The function of rinsing and backwashing is to separate the deposited particles of waste from the filter media and to flush these particles to waste. On the initial start up of the unit it is sound advice to let the unit run for a full 2 weeks before you perform the first rinse and backwash. Frequency of cleaning will depend on your pond size, feeding rates, algae levels, loss of flow etc. We recommend, after the first 2 weeks, to rinse and backwash the unit once or twice a week. The instructions below are relevant for installations that include a non-return valve on the pumps suction line. If you have installed a slide valve or ball valve then you will need to close this valve every time you switch the pump off. CLEANING - RINSE & BACKWASH INSTRUCTIONS Follow the instructions below to clean (rinse and backwash) the K1 Micro Bead Filter. 1. Switch off the pump. 2. Turn the handle on the ball valve fitted just below the air blower to OPEN. 3. Turn the multi-port valve to the RINSE position. 4. Switch the air blower on for 2 minutes. This will agitate the K1 Micro media. Some water will exit the filter to waste. After 2 minutes switch off the blower. 5. IMPORTANT: Turn the handle on the ball valve fitted just below the blower to CLOSE. 6. Leaving the MPV in the RINSE position, loosen one of the air pressure release valves and switch on the water pump. Look at the sight glass on the MPV and when the water runs clear, switch off the pump. 7. Turn the MPV to the BACKWASH position. Switch the pump on and look at the sightglass on the manifold. Water is going to waste. After a very short while, the sight glass will run dirty. When this runs clear, switch the pump off. It is important when performing the BACKWASH that the filter is full with water to remove the waste properly. Release any trapped air by using the air pressure release valve. This will keep the unit filled with water. 8. Move the MPV to the RINSE position again. Switch on the water pump only, and bleed off any air using the air pressure valve and again look at the sight glass. This will flush out any remaining dirt in the unit and pipework. Failure to do this may result in a cloud of debris going back to the pond. When water is running clear, switch off the pump. 9. Move the MPV to the FILTER position and switch the pump back on, ensuring all the air has been bled from the unit. The filter is now clean and fully operational. In extreme cases when the unit has not been backwashed for some time, extend the length of time the blower is running for a more thorough clean or perform a couple of extra rinses. In extreme conditions, performing a backwash first and then following the cleaning instructions can free up any packed media. Do not operate the multi-port valve with the circulating pump switched on. The ball valve must be closed when the circulating pump is running.
13 QUICK CLEANING / BACKWASH INSTRUCTIONS Do not operate the multi-port valve with the circulating pump switched on. The ball valve must be closed when the circulating pump is running. PUMP OFF RINSE AND BLOWER FOR 2 MINUTES RINSE AND PUMP UNTIL CLEAR BACKWASH AND PUMP UNTIL CLEAR RINSE AND PUMP UNTIL CLEAR FILTER AND PUMP Switch PUMP OFF. Turn the ball valve to OPEN. Turn the MPV to the RINSE position. Switch the AIR BLOWER ON for 2 minutes. After 2 minutes switch the AIR BLOWER OFF. Turn the ball valve to CLOSE. Leave the MPV in the RINSE position, switch the WATER PUMP ON. When water runs clear through the sight glass, switch the WATER PUMP OFF. Turn the MPV to the BACKWASH position. Switch the WATER PUMP ON. When water runs clear through the sight glass, switch the pump WATER PUMP OFF. Move the MPV to the RINSE position. Switch the WATER PUMP ON. When water is running clear, switch off the WATER PUMP OFF. Move the MPV to the FILTER position. Switch the WATER PUMP ON. The filter is now clean and fully operational. HOW TO GET THE BEST FROM YOUR K1 MICRO BEAD FILTER The biological side of the filter can take anywhere between 4 to 8 weeks to fully mature. To speed up this process, add the award winning PUREPOND to the filter. Top tips for optimum biological performance: For best results for the prevention of green water use an evouv pond clarifier. A UV-C is recommended on every pond installation. Maintain a stable pond ph of 7 or higher. Maintain a pond Nitrate reading of 50mg/l or less. Always dechlorinate your mains water. Use an Evolution Aqua Dechlorinator for removal of harmful chlorine when topping up with mains water. Add PUREPOND to the filter media inside the K1 Micro Bead Filter. Feed your fish Evolution Aqua s own food range which has been designed to create less fish waste. Ask your local EA dealer for advice. 13
14 WINTER MAINTENANCE Shutting down for Winter If you live in an area, or have installed the K1 Micro Bead Filter in a position that will experience sub zero temperatures, you may decide to shut your filter down for the Winter. Here is a guide on how to do this: 1. Perform a thorough rinse and backwash of the filter, then move the MPV to the CLOSE position. 2. Close any in-line valves before and after the K1 Micro Bead Filter. 3. Open the air pressure release valve at the top of the unit. 4. Open the drain plug at the base of the unit. Water will drain from the vessel. 5. Loosen all connections and drain water from valves, pipes, pumps and UVs. Ensure that no water is trapped. Remember water can expand by 10% when it is ice and can cause permanent damage. Starting up for Spring 1. Add PUREPOND balls to the K1 Micro Bead Filter. 2. Tighten up all connections that were undone over Winter, including the drain plug. 3. Tighten the air pressure release valve. 4. Move the multi-port valve to the FILTER position and switch pump on. Check for leaks. Your K1 Micro Bead Filter is fully operational. 5. The K1 Micro Bead Filter Media will mature quickly. Monitor water readings for the first 2 weeks. 14
15 TROUBLE SHOOTING Dirty Water Short filtration cycles Above normal or excessive force is needed to operate the multi-port valve Filter media has gelled / stuck together 1. Insufficient filtration time 2. Low flow 3. Dirty filter requires rinsing and backwashing 4. Pump has blocked. 5. Inlet line is blocked. 6. Pump is not primed. 7. Incorrect water chemistry. Check ph and other water readings. Check UV is working correctly (replace UV bulbs older than 6-12 months). 8. Clogged or channelled media. Perform an extra long rinse and backwash. Too much algae. Excessive water flow and pressure. Check pump size. Overloaded with fish. Excessive feeding. Filter blocked through calcium. Scoring or jamming with foreign matter or debris. If this condition persists after rinsing, disassemble the valve to clear. Continued operation may result in leaking due to damage to the multi-port valve (spider gasket). See dealer or installer. Switching the Air Blower ON and OFF 2 or 3 times and performing multiple rinses can free up media. Performing a backwash prior to following the cleaning instructions can free up the media. Operating the filter on re-circulate will determine if the restriction is in the filter. If you don t succeed when following the two points above, switch off the pump, isolate and drain the filter. Manually drain the filter, remove the lid and inspect the inside of the unit. The media may need to be removed and cleaned. 15
16 WARRANTY Your K1 Micro Bead Filter comes with a one year warranty. To activate an extra one year warranty please complete and tear out the warranty card and send it to the address below. Warranties Evolution Aqua, Kellet Close, Wigan, Lancashire, WN5 0LP WARRANTY 1. Your K1 Micro Bead Filter is covered by your warranty for 1 year from the date of purchase (2 years if the warranty card is correctly completed and returned) provided that: a. It is installed, operated and regularly maintained in accordance with the instruction manual. b. Any warranty repairs to the K1 Micro Bead Filter must be undertaken by Evolution Aqua Ltd or its authorised representatives. c. A proof of purchase will be required when making a warranty claim. 2. Though the warranty period may not have expired, payment for repairs must be made in the following cases: a. When the fault is due to misuse or unauthorised repairs have been attempted. b. When the fault is due to fire, natural disaster, act of God etc. c. If the warranty has been lost, incorrectly completed or details fraudulently changed. Evolution Aqua Ltd. accepts no responsibility or liability for any consequential loss caused by or arising from the use of any Evolution Aqua products. Therefore, any dispute arising from the provisions of the warranty will be dealt with under the laws of England and Wales subject to the exclusive jurisdiction of the English Courts. 16
17 WARRANTY CARD WARRANTY PROVISIONS WARRANTY CARD 1. Your K1 Micro Bead Filter is covered by your warranty for 1 year from the date of purchase (2 years if the warranty card is correctly completed and returned) provided that: a. It is installed, operated and regularly maintained in accordance with the instruction manual. b. Any warranty repairs to the K1 Micro Bead Filter must be undertaken by Evolution Aqua Ltd or its authorised representatives. c. A proof of purchase will be required when making a warranty claim. 2. Though the warranty period may not have expired, payment for repairs must be made in the following cases: a. When the fault is due to misuse or unauthorised repairs have been attempted. b. When the fault is due to fire, natural disaster, act of God etc. c. If the warranty has been lost, incorrectly completed or details fraudulently changed. Evolution Aqua Ltd. accepts no responsibility or liability for any consequential loss caused by or arising from the use of any Evolution Aqua products. Therefore, any dispute arising from the provisions of the warranty will be dealt with under the laws of England and Wales subject to the exclusive jurisdiction of the English Courts. ACTIVATE YOUR 1 YEAR EXTRA FREE WARRANTY COVER, COMPLETE THE FORM & POST IT TODAY, OR GO TO AND COMPLETE ONLINE. WARRANTIES - EVOLUTION AQUA - KELLET CLOSE - WIGAN - LANCASHIRE - WN5 0LP - TEL:
18 WARRANTY CARD Your Name: Customer Address: Postcode: Country: Tel: Mobile: Purchased From: Address: Postcode: Country: Tel: Web: Date of Purchase: / / Model: Serial Number: I have read and accept the terms and conditions listed in the warranty card, and understand the obligations of the Customer under this warranty. Signature: Date: / / Returning this registration form will amount to your consent for us to disclose your details and other personal information to other companies within the Evolution Aqua group including any subsidiary company or subcontractor of Evolution Aqua for the purposes of performing our obligations under the warranty. Evolution Aqua Ltd. may contact you in the future with product updates or offers, which may be of interest to you. If you do not wish to receive this information please tick this box. WARRANTIES - EVOLUTION AQUA - KELLET CLOSE - WIGAN - LANCASHIRE - WN5 0LP - TEL:
19 NOTES 19
20 Evolution Aqua are the award winning pond filtration manufacturer who put innovation, research and development at the top of their agenda. With a proven track record for delivering the latest technology to the aquatics and fish farming markets - we are the first choice for everyone from the general hobbyist to the serious fishkeeper. Find out more about the K1 Micro Bead Filter and all of our other innovative products at The difference is clear. Evolution Aqua Ltd Evolution House Kellet Close Wigan Lancashire United Kingdom WN5 0LP t: +44 (0) f: +44 (0) e: [email protected] w:
Installation & Operating Instructions
MANEP08082011 Installation & Operating Instructions Note: Please read this manual thoroughly before installation and operation Thank you for purchasing your new EazyPod filter. We are sure you will be
WARNING: Ensure that the UV is switched off at the mains before you attempt to conduct any type of maintenance on the EazyPod Complete.
EPC12204151MAN UK English INSTALLATION AND OPERATING MANUAL WARNING: Ensure that the UV is switched off at the mains before you attempt to conduct any type of maintenance on the EazyPod Complete. Evolution
Installation & Operating Instructions
300 G R A V I T Y F E D Installation & Operating Instructions Note: Do not attempt to operate this unit before reading the manual thoroughly Manufactured by Evolution Aqua Ltd. Evolution House Kellett
A Guide to Trouble-Free Cooling Towers
A Guide to Trouble-Free Cooling Towers A basic understanding of cooling tower operation and maintenance will help keep a cooling water system running in top condition, year after year By David M. Suptic
ClearView 100. Instruction Manual
ClearView 100 Instruction Manual Important Safeguards This appliance is not intended for use by children or infirm persons without supervision. Young children should be supervised to ensure that they do
BF Series Sa S n u d p Fe i r l C t l e e r a n Installation Manual -1-
Installation Manual -1- What happens to the water in your pool? This should be a question of prime consideration for all pool owners. In the past some pools did not use filtering systems, the owner was
SWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor
Maintenance Guide For Above Ground Pools
Maintenance Guide For Above Ground Pools Includes: General Operations/Overview......... page 2 The Five Keys to Pool Care............ page 2 Pump Operations............... page 3 Filter Operations...............
FAQ s & Product & Troubleshooting Guide 37
FAQ s & TROUBLESHOOTING GUIDE Pool Water Treatment SIMPLE DIRECTIONS FOR THE TREATMENT OF AUSTRALIAN SWIMMING POOL WATER SANITISATION: The approved form for sanitisation for Australian swimming pools is
POOL SUNSHINE IONIZER MODELS SPD, SPD2 AND SPS INSTALLATION INSTRUCTIONS
Sunshine Pool Products, LLC Manufacturer of Quality Pool & Spa Products 902 W 2010 S, Syracuse, Utah 84075 USA Voice: 801-825-4523 Website: www.sunshinepool.com Email: [email protected] POOL SUNSHINE
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
Design Utility Lever Thermostatic Bath Shower Mixer
Design Utility Lever Thermostatic Bath Shower Mixer Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts General Information Thank
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER Part Number PCD E3 009B MM Rev 1 Nov. 2010 INTRODUCTION The purpose of this manual
CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)
CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive
100 Series Maxi Internal Filters. Instruction Manual
100 Series Maxi Internal Filters Instruction Manual Important Safeguards This appliance is not intended for use by children or infirm persons without supervision. Young children should be supervised to
ETL listed for installations within 5 ft. (1.5M) of outer edge of water www.srsmith.com 79-15152-00 Rev E2 9.14 Page 1 of 10
Color Light Streams Large Laminar Installation Manual (CLSLL) Input Power: Total Power: 12V AC 5W 4008814 ETL listed for installations within 5 ft. (1.5M) of outer edge of water 79-15152-00 Rev E2 9.14
CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual
CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual Goodway Technologies Corporation 420 West Avenue Stamford, CT 06902-6384 (203)359-4708 Sales: 1-800-333-7467 Customer Service: 1-800-370-2855
WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS
1 WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS Please read and follow all these instructions carefully before proceeding with the installation,
Standard Hydraulic Piping Flushing Procedure
Page 1 of 6 1.0 Scope This procedure covers the minimum technical requirements for cleaning and flushing of Hydraulic and Piping, and related accessories. 2.0 Introduction In hydraulic fluid power systems,
AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS
AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS Products Include: 60 gpm eductors Style 3060, 3061, 3062 & 3070 95 gpm eductors Style
Troubleshooting Salt Generators
Troubleshooting Salt Generators NOTE Turn off power to unit prior to attempting service or repair. Problems and Corrective Action Problem Possible Cause Corrective Action Low or no chlorine. Low stabilizer
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com INTRODUCTION The purpose of this manual is to assist you in the assembly, operation and maintenance of your sprayer
Compact Skimmerfilter
Customer Service Information SAViO Engineering, Inc. 6701 Jefferson NE Albuquerque, NM 87109 USA http://www.savio.com email: [email protected] Warranty (Send in the enclosed warranty card) SAViO Engineering,
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet
Operation & Maintenance Manual
Manual # OMAV2-SUMP1 High Performance Air & Dirt Separators Manual # 9636-1230 Rev. A Operation & Maintenance Manual 340 West 8 th Street Peru, IN 46970 PH: 765 472 3351 FX: 765 472 3968 www.thrushco.com
Please read and keep these instructions. Run water through your machine before first use
47070 Rev 1 24/3/05 2:23 PM Page 1 12 cup filter coffee maker Please read and keep these instructions getting the best from your new coffee maker Safety first Caution must be used when handling hot water,
Operating Manual Color Changing Fountains
Operating Manual Color Changing Fountains 1-877-80-PONDS www.atlanticwatergardens.com Introduction Thank you for purchasing Atlantic s Color Changing Fountains overflowing features that glow from within.
INTRODUCTION WARNING S!!! VOC SHOULD BE BETWEEN 78 95. MUST NOT EXCEED 96 VOC USE DC CIRCUIT BREAKER/ISOLATOR BETWEEN SOLAR PANELS & CONTROLLER
INTRODUCTION Thank you for purchasing a WATERBOY pumping system. We set the standard for quality and economy in solar pumping. The WATERBOY range incorporates the best solar pump technologies that were
Chapter 7 Hydraulic System Troubleshooting
Chapter 7 Hydraulic System Troubleshooting General The following troubleshooting information is provided as a general guide to identify, locate and correct problems that may be experienced with the hydraulic
MODEL 300505 INSTALLATION INSTRUCTIONS
WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 [email protected] Your pump has been carefully packaged at the factory to prevent damage during shipping.
Instruction Manual. Filter System Bioflow Super. www.juwel-aquarium.com
Instruction Manual Filter System Bioflow Super www.juwel-aquarium.com Introduction Thank you for choosing a JUWEL Aquarium product. Our products represent over 40 years experience in the manufacturing
The Worcester Greenstar System Filter. An innovative solution for reducing system contaminants
The Worcester Greenstar System Filter An innovative solution for reducing system contaminants Protect your customer s heating system with the Greenstar System Filter Modern condensing boilers are precision
Rules for Safe Operation
Rules for Safe Operation Important: Do not attempt to operate the CleanStation until you have read and understand all of the instructions in this manual. Failure to do so may result in injury. The machine
Hydraulic Air Riveter. Operation Manual RC197 RC198. Recommend for mass production line industrial area. Page 1
Hydraulic Air Riveter Recommend for mass production line industrial area Operation Manual RC197 RC198 Page 1 CONTENTS 1 Important Safety Rules 2 Tool Specification 2.1 Nomenclature 2.2 Technical Data 3
1/3 HP Submersible Sump Pump with Vertical Float Switch
1/3 HP Submersible Sump with Vertical Float Switch Item 68476 Specifications Float Switch Operation Height 7.1 IN. ON / 2.8 IN. OFF Electrical Requirements 120V~ / 60Hz / 7.6A Power Length Maximum Capacity
IMPORTANT INFORMATION SERIAL NUMBER
O W N E R S M A N U A L IMPORTANT INFORMATION SERIAL NUMBER English For customer service or support: Please mail Warranty Card immediately. For on-line support: To contact Polaris: US and Canada Australia
ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.
ITE Indirect calorifier ITE - 400/500/600/750/1000 0310 117 Installation, User and Service Manual Innovation has a name. Read this manual carefully Warning Read this manual carefully before starting the
Coolflo Safe Touch Shower Mixing Valve ST20015CP
Coolflo Safe Touch Shower Mixing Valve ST20015CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept
OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS
OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS THE LOUISVILLE AND JEFFERSON COUNTY METROPOLITAN SEWER DISTRICT
Bradlee Boilers Ltd. Instruction Manual for starting up Bradlee Hire Boiler from Cold
Bradlee Boilers Ltd Instruction Manual for starting up Bradlee Hire Boiler from Cold To be read in conjunction with Bradlee Boiler guide to Commissioning Boilers Document Ref: HM001 1. Ensure that all
TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES EFFECTIVE: OCTOBER 2007
TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES 301.010 ANNUAL SERVICE TEST FOR FIRE HOSE EFFECTIVE: OCTOBER 2007 The Department will test all fire hose annually. The testing of fire hose determines its serviceability.
Trouble Shooting. Pump
Trouble Shooting Pump Trouble Possible Cause Remedy Oil leaking in the area of water pump crankshaft Worn crankshaft seal, bad bearing, grooved shaft, or failure of retainer o-ring. Excessive play on crankshaft
WATER VALVE OWNER S MANUAL 004-027-8742-00 REV051811
WATER VALVE OWNER S MANUAL 004-027-8742-00 REV051811 295 East Corporate Place Suite 100 Chandler, AZ 85225 Toll Free: 1.800.621.5886 Phone: 480.893.7607 Fax: 480.753.3397 [email protected] www.1paramount.com
Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE
Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent
STABITHERM INSTALLATION & SERVICE BOOKLET
STABITHERM INSTALLATION & SERVICE BOOKLET TABLE OF CONTENTS Introduction...3 Warranty...3 Product Range and Physical Description...4 Method of Operation...5 Recommended Pressures and Temperatures...6 Flow
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com INTRODUCTION The purpose of this manual is to assist you in the assembly, operation and maintenance of your sprayer
User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.
User s Guide Oreck Air Purifier with HEPA Filtration Important! Read this manual carefully, and keep for future reference. Enjoy Congratulations on your purchase of the Oreck Air Purifier with HEPA Filtration.
Fiberstars Lighted Laminar Flow Fountain Installation Manual
Fiberstars Lighted Laminar Flow Fountain Installation Manual 79-15037-00 REV Xx http://www.fiberstars.com Page 1 of 8 SAVE THESE DIRECTIONS! These directions are provided to ensure the proper installation
Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.
OFF COOL 0 3 2 1 OFF Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use ON SPEED ON SWING OWNER S MANUAL Read and save these instructions before use Model: CO60PM Power rating: 220 Watts
Float and Thermostatic Traps Series H, C and X
Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT
A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps
A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps Troubleshooting Submersible Pumps Fuse overload or circuit breaker trips when motor is started 1. Incorrect line voltage. Check the line
O W N E R S M A N U A L SERIAL NUMBER
O W N E R S M A N U A L IMPORTANT INFORMATION SERIAL NUMBER Important Information Before installing the Polaris, make sure the pool filter is clean. New plumbing lines should be flushed out before installing
HAYWARD POOL PRODUCTS, INC. 620 Division Street Elizabeth, NJ 07207 Tel: 908-351-5400 WWW.HAYWARDPOOL.COM
IS170TSC Rev. B OWNER S MANUAL INSTALLATION, OPERATION & PARTS MODELS: S170TSCPE S190TSCPE S190TSCPFT S190TSCPT HIGH-RATE SAND FILTER Basic safety precautions should always be followed, including the following:
Colonial Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts
Colonial Tap Range Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the UK s leading
93052/1115-V05. C260 User Manual
93052/1115-V05 C260 User Manual QUICK GUIDE Preparing waste-holding tank 1 2 3 4 5 6 7 8 9 10 11 12 Preparing flush-water tank (only for C262-models) 13 14 15 16 Preparing Electric Ventilator (if applicable)
Vaillant s plain English guide to. simple, concise and precise
Vaillant s plain English guide to simple, concise and precise Introduction Contents Installing a new boiler 05 Servicing and repairing 13 What s a diverter valve? Why do you need a TRV? And happens when
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50
Back Pack Sprayer Operator's Manual MODELS MS - 40 MS - 50 WARNING DANGER Read rules for safe operation and all instructions carefully. ECHO provides this Operator's Manual which must be read and understood
Hydraulics Trouble Shooting Guide. TS-Guide_R.doc
Hydraulics Trouble Shooting Guide TS-Guide_R.doc Table of Contents Condensed Table... 1 Valves... 3 Cylinders... 3 Boosters... 4 Fluid Motors... 5 Vane Pumps... 6 Radial Piston Pumps... 9 Hydraulic Systems...
Liquorice Kitchen Sink Tap
Liquorice Kitchen Sink Tap Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the UK s
Artisan Thermostatic basin mixer. Fitting Instructions & Contents List
Artisan Thermostatic basin mixer Fitting Instructions & Contents List Please keep these instructions for future reference and request of replacement parts 1. Introduction Thank you for choosing Bristan,
Artisan Thermostatic Bath Shower Mixer
Artisan Thermostatic Bath Shower Mixer Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts General Information Thank you for choosing
POOL ROVER SERIES 2 ROBOTIC POOL CLEANER PRODUCT SETTINGS AND TROUBLESHOOTING GUIDE
820406 POOL ROVER SERIES 2 ROBOTIC POOL CLEANER PRODUCT SETTINGS AND TROUBLESHOOTING GUIDE PLEASE READ CAREFULLY BEFORE USING YOUR POOL CLEANER Aqua Products, Inc 282 Grove Avenue Cedar Grove, NJ 07009
Iron Air Charge 2510-SXT Installation & Start-Up Guide
Iron Air Charge 2510-SXT Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your system will be providing iron free water
Technical Guide 08/15/14
Technical Guide 08/15/14 1 Table of Contents Contact information.3 Identifying your system..4-8 Model Number Serial number location Parts of your fuel system..9-14 Fuel pump diagram Wire harness schematics
Installation Instructions 4508 4508S
SYMPHONY Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect
Overheating limit control
Pahlén electric heater Maxi Heat with digital control is a compact and effective heater for swimming pools. It consists of a glassfibre reinforced polypropylene tank containing resistance-type heating
Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL25AE
Portable Evaporative Air Cooler for Indoor Use OWNER S MANUAL Read and save these instructions before use Model: CL25AE Power rating: 230 Watts Voltage rating: 120 Volt AC, 60Hz For product inquiries or
Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC
Portable Evaporative Air Cooler OWNER S MANUAL Read and save these instructions before use Model: CL30XC Power rating: 250 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C. QUICK START GUIDE Fill with
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
Operating Manual & Specifications
SS0000 Read entire instructions prior to installing the unit. SAViO Skimmerfilter Operating Manual & Specifications Congratulations on purchasing the highest quality Skimmerfilter available. Familiarize
Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual
Speedflow Undersink Unvented Water Heater Models SF10K and SF15K Instruction Manual Version 2.0 May 2009 Hyco SpeedFLOW UnVENTED WATER HEATER Models SF10K (10 Litres) and SF15K (15 Litres) 1. Introduction
Swimming Pool Equipment Maintenance Tips What You Need To Know To Avoid Frustration AND Save Money
Swimming Pool Equipment Maintenance Tips What You Need To Know To Avoid Frustration AND Save Money Re: Proper equipment maintenance From: The desk of Terry Duff. If you re frustrated with taking care of
Troubleshoot resources for homeowner http://waterheatertimer.org/troubleshoot-bosch-tankless-water-heater.html
Troubleshoot resources for homeowner http://waterheatertimer.org/troubleshoot-bosch-tankless-water-heater.html Installation / Operating Instructions GOOD.BEETER>BOSCH Water Wizard 600 Continuous Flow Gas
Select Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL
Electric Kettle Model: SK-1717 INSTRUCTIONS MANUAL Thank you for your purchase. Please read this Instruction Manual thoroughly before use and keep in a safe place for future reference. READ ALL INSTRUCTIONS
Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer
Overview READ ENTIRE INSTRUCTIONS BEFORE STARTING INSTALLATION PARTS LIST A. Flush valve B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve
CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.
CAST IRON THE BASICS 1. DO NOT LIFT ON YOUR OWN. 2. ONLY LIFT THE RADIATOR VERTICALLY. 3. DO NOT LIFT MORE THAN 8/10 SECTIONS AT ANY ONE TIME. 4. POSITION THE RADIATOR BEFORE FINAL ASSEMBLY. 5. THIS PRODUCT
MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS with the 263/742 Logix Control Valve June 2010 Table of Contents Page No.
Water Garden Workshop
The Water Garden Workshop Company Under-Gravel Spider Filter System. INSTALLATION GUIDELINES Crystal clear water, naturally We are very pleased that you have selected to use the revolutionary under-gravel
STREAMLINE. Products for the Pure Water Cleaning Industry INSTRUCTION MANUAL
STREAMLINE Products for the Pure Water Cleaning Industry INSTRUCTION MANUAL PRODUCT DENVER Honda Powered Pressure Washing Bowser. TANK SIZES 450Ltr, 600Ltr, 800Ltr WARRANTY Covered for one year from recorded
OZOMATIC OWNERS MANUAL
P/N 401833 OZOMATIC OWNERS MANUAL Page 1. INTRODUCTION: 3 2. RUNNING TIME: 3 3. SPA/POOL BALANCE: 4 4. TROUBLE SHOOTING: 4 5. GENERAL INFORMATION: 5 6. OZOMATIC INJECTION SYSTEMS: 5-9 7. 24 HOUR CIRCULATION
TABLE OF CONTENTS 2 CONGRATULATIONS 3 THE BOSCH STORY 3 PRODUCT OVERVIEW 3 PRODUCT DIAGRAM 4 OPERATING INSTRUCTIONS 5 TROUBLE SHOOTING 6
1 TABLE OF CONTENTS 2 CONGRATULATIONS 3 THE BOSCH STORY 3 PRODUCT OVERVIEW 3 PRODUCT DIAGRAM 4 OPERATING INSTRUCTIONS 5 TROUBLE SHOOTING 6 CARE & SERVICING OF THE UNI T 6 10 BASIC STEPS FOR INSTALLATION
Rexroth Hydraulic Pump A10VO Series User Manual
Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)
INSTRUCTION MANUAL A-00-091-376 REVISION A. Series E1 and E3 Instant Hot Water Recirculating Systems
INSTRUCTION MANUAL A-00-091-376 REVISION A Series E1 and E3 Instant Hot Water Recirculating Systems HOT WATER HEATER HOT WATER HEATER BS Models A. Return into Cold Water Line at Top of Water Heater fig.
STEAM HEATING SYSTEM TROUBLESHOOTING GUIDE
Page 1 of 9 PURPOSE Steam is the most commonly used heating medium for maintaining process temperatures. Compared to other heating media, steam contains a significant amount of heat energy, and this heat
INSTALLATION & OPERATING INSTRUCTIONS
INSTALLATION & OPERATING INSTRUCTIONS WARNING RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A CIRCUIT PROTECTED BY A GROUND-FAULT CIRCUIT-INTERRUPTER. THE UNIT SHOULD BE INSTALLED BY A QUALIFIED SERVICE REPRESENTATIVE.
OTF Oil Fired Pool Heater
OTF Oil Fired Pool Heater Installation Operation Maintenance Manual Service Policy 722010 Congratulations on the purchase of your new pool heater. In order to maintain peak performance of your pool heater
PRIVATE WATER SUPPLY - WATER SAFETY MAINTENANCE PLAN
PRIVATE WATER SUPPLY - WATER SAFETY MAINTENANCE PLAN WHY ROUTINE MAINTENANCE? Compared to the public water supply, private water supplies are more likely to be contaminated with bacteria, protozoa, viruses
Volkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)
17 Engine-Lubrication (Page GR-17) Lubrication system components, removing and installing Oil filter housing, disassembling and assembling Oil pan, removing and installing Oil pressure and oil pressure
HEAT PUMP FOR SWIMMING POOL Installation and Instruction Manual
HEAT PUMP FOR SWIMMING POOL Installation and Instruction Manual Revision 1.0 12.11.2013 Table of contents Table of contents... 2 1. Preface... 3 2. Specifications... 4 2.1 Performance data... 4 3. Installation
NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL
NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. Esenboğa Yolu 22 km Akyurt - ANKARA / TURKEY Tel : (00 90 312)
AquaMode 300. Instruction Manual
AquaMode 300 Instruction Manual Important Safeguards This appliance is not intended for use by children or infirm persons without supervision. Young children should be supervised to ensure that they do
Cadet Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference
Cadet Tap Range Installation Instructions & User Guide Please keep these instructions for future reference Contents Thank you for choosing Bristan, the UK s leading showers and taps expert. We have designed
Instruction Manual. Image of SP-3015 & SP-3815. Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function
Important Safeguards READ ALL INSTRUCTIONS BEFORE USE. Instruction Manual Automatic Dispensing Hot Water Pot with Reboil Function Image of SP-3015 & SP-3815 SP-3015: 3.0L SP-3815: 3.8L SP-3017: 3.0L (Stainless
Global Water Instrumentation, Inc.
Global Water Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 6 Tipping Bucket: RG200 02/05/10 01-343 - 1 - Congratulations on your
Maxi Pressurisation Units (Maxi, Maxi Plus & HP)
Maxi Pressurisation Units (Maxi, Maxi Plus & HP) Installation and Maintenance Instructions Contents 1 Dimensions 3 1.1 Installation 4 1.1 Mains/boosted cold water inlet 4 1.2 Connection to the system 5
Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation
Solar Pool Heating System Installation Manual Read the complete manual before beginning the installation 1. Sizing the System Visit www.techno-solis.com to size the system using the sizing calculator.
TYPE E Main Valve Sizes 3 /8 through 12
SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,