3 3RG78 45 program overview

Size: px
Start display at page:

Download "3 3RG78 45 program overview"

Transcription

1 Overview RG78 45 light curtains and arrays with integrated processing unit for type 4 in accordance with IEC/EN With "Standard" function package Resolutions: 14, 0, 50, and 90 Protective zone height: 150 to beam, -beam or 4-beam light arrays Cascading of host and guest devices for greater protective zone heights or lengths or for an angular arrangement (optional). Two standard RG AB mounting brackets each are enclosed with all devices (can also be ordered as accessories). RG78 45 program overview Unit type Function package Output Connection type For light curtains: Resolution For light arrays and transceivers: Range Light curtains N Standard Transistor M12 plug connector /6 Light arrays N Standard Transistor M12 plug connector 0.8 m to 18 m; 6 to 60 m /8 Transceiver N Standard Transistor M12 plug connector 6.5 m /8 Light curtains N Standard Transistor Hirschmann /9 Light arrays N Standard Transistor Hirschmann 0.8 m to 18 m; 6 to 60 m /40 Transceiver N Standard Transistor Hirschmann 6.5 m /40 Light curtains N Standard Transistor Brad Harrison (MIN) 1) /41 Light arrays N Standard Transistor Brad Harrison (MIN) 1) 0.8 m to 18 m; 6 to 60 m /4 Transceiver N Standard Transistor Brad Harrison (MIN) 1) 6.5 m /4 Light curtains N Standard Transistor Cable gland /44 Light arrays N Standard Transistor Cable gland 0.8 m to 18 m; 6 to 60 m /46 Transceiver N Standard Transistor Cable gland 6.5 m /46 Accessories Electrical connection Hirschmann type cables and cable plugs /85 Brad-Harrison type cable (MIN series) /85 Connecting cable with M12 connection /86 Assembly materials Fixing columns, reflecting mirror /8 Muting mounting systems /84 Muting accessories /86 Laser alignment aids, diagnostic software /84 see Page 1) Required primarily for applications in the NAFTA market /4 Siemens FS

2 Technical specifications Type RG78 45 Safety category to Type 4 (self-monitoring) EN, IEC , - Detection capability (resolution) 14, 0, 50, 90 or whole person with 2, or 4 beams Protective field height for 14 and 0 resolution for 50 resolution for 90 resolution Protective field width, sensing field for 14 resolution m for 0, 50 and 90 resolution m for 18 m light array m for 60 m light array m Supply voltage (emitter and receiver) Current consumption Emitter Receiver Vibration resistance Shock resistance Infrared stray light suppression Standard d-scan Synchronization between emitter and receiver Ambient temperature 24 V DC ± 20% (external power pack with safe isolation and 20 ms voltage power loss ride-through) 75 ma 180 ma (without external load) 5 g, Hz to IEC/EN g, 16 ms to IEC/EN procedures may be selected High suppression Very high suppression (response time increases in units with more than 15 beams) Optical; 2 transmission channels can be selected Operation C Storage C Humidity % Type of protection IP65 Electrical connection via Pg 1 screw-type terminals and pluggable wiring space Connecting cable Emitter 7-pin: Receiver 7-pin: (shielded, if necessary) Cable length for m Inputs Emitter test input Minimum opening duration Closed-circuit principle 50 ms Outputs Safety outputs 2 failsafe pnp outputs with cross-circuit monitoring (short circuit proof) Output voltage U a min U vers 2.7 V Output current I a max 0. A Peak current 0.4 A Continuous current at 5 C 0. A at 55 C 0.22 A Max. load capacity per output 00 nf (100 nf at channel 2) Response time from the protective field interrupt to disconnection of the safety outputs Increases with higher number of beams for 14 resolution ms (d-scan ms) for 0 resolution ms (d-scan ms) for 50 resolution 17 ms (d-scan ms) for 90 resolution 1 ms (d-scan 20 ms) for 2,, or 4-beam light arrays 5 ms (d-scan 8 ms) Reactivation time from release of the protective field to connection of the safety outputs For all resolutions 0.5 ms After very brief protective 100 ms field interrupts Pollution and error message output pnp output, short circuit proof Output current, max. 70 ma Safety and diagnostic interfaces RS485, 57.6 kbaud Siemens FS /5

3 Selection and Ordering Data Light curtains with standard function package transistor output with M12 plug connector N Protection Version Standard device Host device Guest device height 14 resolution 150 Receiver A RG78 45-BB01 RG BB Emitter A RG78 45-BB00 RG BB Receiver A RG78 45-BC01 A RG78 45-BC11 RG BC Emitter A RG78 45-BC00 A RG78 45-BC10 RG BC20 00 Receiver A RG78 45-BD01 A RG78 45-BD11 RG BD21 00 Emitter A RG78 45-BD00 A RG78 45-BD10 RG BD Receiver A RG78 45-BE01 A RG78 45-BE11 RG BE Emitter A RG78 45-BE00 A RG78 45-BE10 RG BE Receiver A RG78 45-BF01 A RG78 45-BF11 RG BF Emitter A RG78 45-BF00 A RG78 45-BF10 RG BF Receiver A RG78 45-BG01 A RG78 45-BG11 RG BG Emitter A RG78 45-BG00 A RG78 45-BG10 RG BG Receiver A RG78 45-BH01 A RG78 45-BH11 RG BH Emitter A RG78 45-BH00 A RG78 45-BH10 RG BH Receiver A RG78 45-BJ01 A RG78 45-BJ11 RG BJ Emitter A RG78 45-BJ00 A RG78 45-BJ10 RG BJ Receiver A RG78 45-BK01 A RG78 45-BK11 RG BK Emitter A RG78 45-BK00 A RG78 45-BK10 RG BK Receiver A RG78 45-BL01 A RG78 45-BL11 RG BL Emitter A RG78 45-BL00 A RG78 45-BL10 RG BL Receiver A RG78 45-BM01 A RG78 45-BM11 RG BM Emitter A RG78 45-BM00 A RG78 45-BM10 RG BM Receiver A RG78 45-BN01 A RG78 45-BN11 RG BN Emitter A RG78 45-BN00 A RG78 45-BN10 RG BN Receiver A RG78 45-BP01 A RG78 45-BP11 RG BP Emitter A RG78 45-BP00 A RG78 45-BP10 RG BP20 0 resolution 150 Receiver A RG78 45-DB01 RG DB Emitter A RG78 45-DB00 RG DB Receiver A RG78 45-DC01 A RG78 45-DC11 RG DC Emitter A RG78 45-DC00 A RG78 45-DC10 RG DC20 00 Receiver A RG78 45-DD01 A RG78 45-DD11 RG DD21 00 Emitter A RG78 45-DD00 A RG78 45-DD10 RG DD Receiver A RG78 45-DE01 A RG78 45-DE11 RG DE Emitter A RG78 45-DE00 A RG78 45-DE10 RG DE Receiver A RG78 45-DF01 A RG78 45-DF11 RG DF Emitter A RG78 45-DF00 A RG78 45-DF10 RG DF Receiver A RG78 45-DG01 A RG78 45-DG11 RG DG Emitter A RG78 45-DG00 A RG78 45-DG10 RG DG Receiver A RG78 45-DH01 A RG78 45-DH11 RG DH Emitter A RG78 45-DH00 A RG78 45-DH10 RG DH Receiver A RG78 45-DJ01 A RG78 45-DJ11 RG DJ Emitter A RG78 45-DJ00 A RG78 45-DJ10 RG DJ Receiver A RG78 45-DK01 A RG78 45-DK11 RG DK Emitter A RG78 45-DK00 A RG78 45-DK10 RG DK20 /6 Siemens FS

4 Protection Version Standard device Host device Guest device height 150 Receiver A RG78 45-DL01 A RG78 45-DL11 RG DL Emitter RG78 45-DL00 A RG78 45-DL10 RG DL Receiver A RG78 45-DM01 A RG78 45-DM11 RG DM Emitter A RG78 45-DM00 A RG78 45-DM10 RG DM Receiver A RG78 45-DN01 A RG78 45-DN11 RG DN Emitter A RG78 45-DN00 A RG78 45-DN10 RG DN Receiver A RG78 45-DP01 A RG78 45-DP11 RG DP Emitter A RG78 45-DP00 A RG78 45-DP10 RG DP20 50 resolution 450 Receiver A RG78 45-EE01 A RG78 45-EE11 RG EE Emitter A RG78 45-EE00 A RG78 45-EE10 RG EE Receiver A RG78 45-EF01 A RG78 45-EF11 RG EF Emitter A RG78 45-EF00 A RG78 45-EF10 RG EF Receiver A RG78 45-EG01 A RG78 45-EG11 RG EG Emitter A RG78 45-EG00 A RG78 45-EG10 RG EG Receiver A RG78 45-EH01 A RG78 45-EH11 RG EH Emitter A RG78 45-EH00 A RG78 45-EH10 RG EH Receiver A RG78 45-EJ01 A RG78 45-EJ11 RG EJ Emitter A RG78 45-EJ00 A RG78 45-EJ10 RG EJ Receiver A RG78 45-EK01 A RG78 45-EK11 RG EK Emitter A RG78 45-EK00 A RG78 45-EK10 RG EK Receiver A RG78 45-EL01 A RG78 45-EL11 RG EL Emitter A RG78 45-EL00 A RG78 45-EL10 RG EL Receiver A RG78 45-EM01 A RG78 45-EM11 RG EM Emitter A RG78 45-EM00 A RG78 45-EM10 RG EM Receiver A RG78 45-EN01 A RG78 45-EN11 RG EN Emitter A RG78 45-EN00 A RG78 45-EN10 RG EN Receiver A RG78 45-EP01 A RG78 45-EP11 RG EP Emitter A RG78 45-EP00 A RG78 45-EP10 RG EP Receiver A RG78 45-ER01 A RG78 45-ER11 RG ER Emitter A RG78 45-ER00 A RG78 45-ER10 RG ER Receiver A RG78 45-ES01 A RG78 45-ES11 RG ES Emitter A RG78 45-ES00 A RG78 45-ES10 RG ES Receiver A RG78 45-ET01 A RG78 45-ET11 RG ET Emitter A RG78 45-ET00 A RG78 45-ET10 RG ET Receiver A RG78 45-EU01 A RG78 45-EU11 RG EU Emitter A RG78 45-EU00 A RG78 45-EU10 RG EU20 90 resolution 750 Receiver A RG78 45-JG01 A RG78 45-JG11 RG JG Emitter A RG78 45-JG00 A RG78 45-JG10 RG JG Receiver A RG78 45-JH01 A RG78 45-JH11 RG JH Emitter A RG78 45-JH00 A RG78 45-JH10 RG JH Receiver A RG78 45-JJ01 A RG78 45-JJ11 RG JJ Emitter A RG78 45-JJ00 A RG78 45-JJ10 RG JJ Receiver A RG78 45-JK01 A RG78 45-JK11 RG JK Emitter A RG78 45-JK00 A RG78 45-JK10 RG JK Receiver A RG78 45-JL01 A RG78 45-JL11 RG JL Emitter A RG78 45-JL00 A RG78 45-JL10 RG JL Receiver A RG78 45-JM01 A RG78 45-JM11 RG JM Emitter A RG78 45-JM00 A RG78 45-JM10 RG JM20 Siemens FS /7

5 Protection Version Standard device Host device Guest device height 1650 Receiver A RG78 45-JN01 A RG78 45-JN11 RG JN Emitter A RG78 45-JN00 A RG78 45-JN10 RG JN Receiver A RG78 45-JP01 A RG78 45-JP11 RG JP Emitter A RG78 45-JP00 A RG78 45-JP10 RG JP Receiver A RG78 45-JR01 A RG78 45-JR11 RG JR Emitter A RG78 45-JR00 A RG78 45-JR10 RG JR Receiver A RG78 45-JS01 A RG78 45-JS11 RG JS Emitter A RG78 45-JS00 A RG78 45-JS10 RG JS Receiver A RG78 45-JT01 A RG78 45-JT11 RG JT Emitter A RG78 45-JT00 A RG78 45-JT10 RG JT Receiver A RG78 45-JU01 A RG78 45-JU11 RG JU Emitter A RG78 45-JU00 A RG78 45-JU10 RG JU20 Light arrays with standard function package transistor output with M12 plug connector N m range 4-beam 00 Receiver A RG78 45-MH01 4-beam 00 Emitter A RG78 45-MH00 -beam 400 Receiver A RG78 45-PG01 -beam 400 Emitter A RG78 45-PG00 2-beam 500 Receiver A RG78 45-SE01 2-beam 500 Emitter A RG78 45-SE m range 4-beam 00 Receiver A RG78 45-MH51 4-beam 00 Emitter A RG78 45-MH50 -beam 400 Receiver A RG78 45-PG51 -beam 400 Emitter A RG78 45-PG50 2-beam 500 Receiver A RG78 45-SE51 2-beam 500 Emitter A RG78 45-SE50 Transceiver with standard function package transistor output with M12 plug connector N 6.5 m range 2-beam 500 Transceiver A RG78 45-TE01 Reflective mirror for transceiver RG TL /8 Siemens FS

6 Light curtains with standard function package transistor output with Hirschmann plug connector N SIMATIC FS400 light curtains and arrays Protection height Version Standard device Host device Guest device 14 resolution 150 Receiver A RG BB01 RG BB Emitter A RG BB00 RG BB Receiver A RG BC01 On request RG BC Emitter A RG BC00 On request RG BC20 00 Receiver A RG BD01 On request RG BD21 00 Emitter A RG BD00 On request RG BD Receiver A RG BE01 On request RG BE Emitter A RG BE00 On request RG BE Receiver A RG BF01 On request RG BF Emitter A RG BF00 On request RG BF Receiver A RG BG01 On request RG BG Emitter A RG BG00 On request RG BG Receiver A RG BH01 On request RG BH Emitter A RG BH00 On request RG BH Receiver A RG BJ01 On request RG BJ Emitter A RG BJ00 On request RG BJ Receiver A RG BK01 On request RG BK Emitter A RG BK00 On request RG BK Receiver A RG BL01 On request RG BL Emitter A RG BL00 On request RG BL Receiver A RG BM01 On request RG BM Emitter A RG BM00 On request RG BM Receiver A RG BN01 On request RG BN Emitter A RG BN00 On request RG BN Receiver A RG BP01 On request RG BP Emitter A RG BP00 On request RG BP20 0 resolution 150 Receiver A RG DB01 RG DB Emitter A RG DB00 RG DB Receiver A RG DC01 On request RG DC Emitter A RG DC00 On request RG DC20 00 Receiver A RG DD01 On request RG DD21 00 Emitter A RG DD00 On request RG DD Receiver A RG DE01 On request RG DE Emitter A RG DE00 On request RG DE Receiver A RG DF01 On request RG DF Emitter A RG DF00 On request RG DF Receiver A RG DG01 On request RG DG Emitter A RG DG00 On request RG DG Receiver A RG DH01 On request RG DH Emitter A RG DH00 On request RG DH Receiver A RG DJ01 On request RG DJ Emitter A RG DJ00 On request RG DJ Receiver A RG DK01 On request RG DK Emitter A RG DK00 On request RG DK Receiver A RG DL01 On request RG DL Emitter A RG DL00 On request RG DL20 Siemens FS /9

7 Protection height Version Standard device Host device Guest device 1500 Receiver A RG DM01 On request RG DM Emitter A RG DM00 On request RG DM Receiver A RG DN01 On request On request 1650 Emitter A RG DN00 On request On request 1800 Receiver A RG DP01 On request On request 1800 Emitter A RG DP00 On request On request Light arrays with standard function package transistor output with Hirschmann plug connector N m range 4-beam 00 Receiver A RG MH01 4-beam 00 Emitter A RG MH00 -beam 400 Receiver A RG PG01 -beam 400 Emitter A RG PG00 2-beam 500 Receiver A RG SE01 2-beam 500 Emitter A RG SE m range 4-beam 00 Receiver A RG MH51 4-beam 00 Emitter A RG MH50 -beam 400 Receiver A RG PG51 -beam 400 Emitter A RG PG50 2-beam 500 Receiver A RG SE51 2-beam 500 Emitter A RG SE50 Transceiver with Standard function package transistor output with Hirschmann plug connector N 6.5 m range 2-beam 500 Transceiver A RG TE01 Reflective mirror for transceiver RG TL /40 Siemens FS

8 Light curtains with standard function package transistor output with Brad Harrison connection (MIN-Series) 1) N SIMATIC FS400 light curtains and arrays Protection height Version Standard device Host device Guest device 14 resolution 150 Receiver A RG BB01 A RG BB Emitter A RG BB00 A RG BB Receiver A RG BC01 A RG BC11 RG BC Emitter A RG BC00 A RG BC10 RG BC20 00 Receiver A RG BD01 A RG BD11 RG BD21 00 Emitter A RG BD00 A RG BD10 RG BD Receiver A RG BE01 A RG BE11 RG BE Emitter A RG BE00 A RG BE10 RG BE Receiver A RG BF01 A RG BF11 RG BF Emitter A RG BF00 A RG BF10 RG BF Receiver A RG BG01 A RG BG11 RG BG Emitter A RG BG00 A RG BG10 RG BG Receiver A RG BH01 A RG BH11 RG BH Emitter A RG BH00 A RG BH10 RG BH Receiver A RG BJ01 A RG BJ11 RG BJ Emitter A RG BJ00 A RG BJ10 RG BJ Receiver A RG BK01 A RG BK11 RG BK Emitter A RG BK00 A RG BK10 RG BK Receiver A RG BL01 A RG BL11 RG BL Emitter A RG BL00 A RG BL10 RG BL Receiver A RG BM01 A RG BM11 RG BM Emitter A RG BM00 A RG BM10 RG BM Receiver A RG BN01 A RG BN11 RG BN Emitter A RG BN00 A RG BN10 RG BN Receiver A RG BP01 A RG BP11 RG BP Emitter A RG BP00 A RG BP10 RG BP20 0 resolution 150 Receiver A RG DB01 A RG DB Emitter A RG DB00 A RG DB Receiver A RG DC01 A RG DC11 RG DC Emitter A RG DC00 A RG DC10 RG DC20 00 Receiver A RG DD01 A RG DD11 RG DD21 00 Emitter A RG DD00 A RG DD10 RG DD Receiver A RG DE01 A RG DE11 RG DE Emitter A RG DE00 A RG DE10 RG DE Receiver A RG DF01 A RG DF11 RG DF Emitter A RG DF00 A RG DF10 RG DF Receiver A RG DG01 A RG DG11 RG DG Emitter A RG DG00 A RG DG10 RG DG Receiver A RG DH01 A RG DH11 RG DH Emitter A RG DH00 A RG DH10 RG DH Receiver A RG DJ01 A RG DJ11 RG DJ Emitter A RG DJ00 A RG DJ10 RG DJ Receiver A RG DK01 A RG DK11 RG DK Emitter A RG DK00 A RG DK10 RG DK Receiver A RG DL01 A RG DL11 RG DL Emitter A RG DL00 A RG DL10 RG DL20 1) Required primarily for applications in the NAFTA market Siemens FS /41

9 Protection height Version Standard device Host device Guest device 1500 Receiver A RG DM01 A RG DM11 RG DM Emitter A RG DM00 A RG DM10 RG DM Receiver A RG DN01 A RG DN11 RG DN Emitter A RG DN00 A RG DN10 RG DN Receiver A RG DP01 A RG DP11 RG DP Emitter A RG DP00 A RG DP10 RG DP20 50 resolution 450 Receiver A RG EE01 A RG EE11 RG EE Emitter A RG EE00 A RG EE10 RG EE Receiver A RG EF01 A RG EF11 RG EF Emitter A RG EF00 A RG EF10 RG EF Receiver A RG EG01 A RG EG11 RG EG Emitter A RG EG00 A RG EG10 RG EG Receiver A RG EH01 A RG EH11 RG EH Emitter A RG EH00 A RG EH10 RG EH Receiver A RG EJ01 A RG EJ11 RG EJ Emitter A RG EJ00 A RG EJ10 RG EJ Receiver A RG EK01 A RG EK11 RG EK Emitter A RG EK00 A RG EK10 RG EK Receiver A RG EL01 A RG EL11 RG EL Emitter A RG EL00 A RG EL10 RG EL Receiver A RG EM01 A RG EM11 RG EM Emitter A RG EM00 A RG EM10 RG EM Receiver A RG EN01 A RG EN11 RG EN Emitter A RG EN00 A RG EN10 RG EN Receiver A RG EP01 A RG EP11 RG EP Emitter A RG EP00 A RG EP10 RG EP Receiver A RG ER01 A RG ER11 RG ER Emitter A RG ER00 A RG ER10 RG ER Receiver A RG ES01 A RG ES11 RG ES Emitter A RG ES00 A RG ES10 RG ES Receiver A RG ET01 A RG ET11 RG ET Emitter A RG ET00 A RG ET10 RG ET Receiver A RG EU01 A RG EU11 RG EU Emitter A RG EU00 A RG EU10 RG EU20 90 resolution 750 Receiver A RG JG01 A RG JG11 RG JG Emitter A RG JG00 A RG JG10 RG JG Receiver A RG JH01 A RG JH11 RG JH Emitter A RG JH00 A RG JH10 RG JH Receiver A RG JJ01 A RG JJ11 RG JJ Emitter A RG JJ00 A RG JJ10 RG JJ Receiver A RG JK01 A RG JK11 RG JK Emitter A RG JK00 A RG JK10 RG JK Receiver A RG JL01 A RG JL11 RG JL Emitter A RG JL00 A RG JL10 RG JL Receiver A RG JM01 A RG JM11 RG JM Emitter A RG JM00 A RG JM10 RG JM Receiver A RG JN01 A RG JN11 RG JN Emitter A RG JN00 A RG JN10 RG JN20 /42 Siemens FS

10 Protection height Version Standard device Host device Guest device 1800 Receiver A RG JP01 A RG JP11 RG JP Emitter A RG JP00 A RG JP10 RG JP Receiver A RG JR01 A RG JR11 RG JR Emitter A RG JR00 A RG JR10 RG JR Receiver A RG JS01 A RG JS11 RG JS Emitter A RG JS00 A RG JS10 RG JS Receiver A RG JT01 A RG JT11 RG JT Emitter A RG JT00 A RG JT10 RG JT Receiver A RG JU01 A RG JU11 RG JU Emitter A RG JU00 A RG JU10 RG JU20 Light arrays with standard function package transistor output with Brad Harrison connection (MIN-Series) 1) N m range 4-beam 00 Receiver A RG MH01 4-beam 00 Emitter A RG MH00 -beam 400 Receiver A RG PG01 -beam 400 Emitter A RG PG00 2-beam 500 Receiver A RG SE01 2-beam 500 Emitter A RG SE m range 4-beam 00 Receiver A RG MH51 4-beam 00 Emitter A RG MH50 -beam 400 Receiver A RG PG51 -beam 400 Emitter A RG PG50 2-beam 500 Receiver A RG SE51 2-beam 500 Emitter A RG SE50 Transceiver with standard function package transistor output with Brad Harrison connection (MIN-Series) 1) N 6.5 m range 2-beam 500 Transceiver A RG TE01 Reflective mirror for transceiver RG TL 1) Required primarily for applications in the NAFTA market Siemens FS /4

11 Light curtains with standard function package transistor output with cable gland N Protection Version Standard device Host device Guest device height 14 resolution 150 Receiver A RG BB01 RG BB Emitter A RG BB00 RG BB Receiver A RG BC01 A RG BC11 RG BC Emitter A RG BC00 A RG BC10 RG BC20 00 Receiver A RG BD01 A RG BD11 RG BD21 00 Emitter A RG BD00 A RG BD10 RG BD Receiver A RG BE01 A RG BE11 RG BE Emitter A RG BE00 A RG BE10 RG BE Receiver A RG BF01 A RG BF11 RG BF Emitter A RG BF00 A RG BF10 RG BF Receiver A RG BG01 A RG BG11 RG BG Emitter A RG BG00 A RG BG10 RG BG Receiver A RG BH01 A RG BH11 RG BH Emitter A RG BH00 A RG BH10 RG BH Receiver A RG BJ01 A RG BJ11 RG BJ Emitter A RG BJ00 A RG BJ10 RG BJ Receiver A RG BK01 A RG BK11 RG BK Emitter A RG BK00 A RG BK10 RG BK Receiver A RG BL01 A RG BL11 RG BL Emitter A RG BL00 A RG BL10 RG BL Receiver A RG BM01 A RG BM11 RG BM Emitter A RG BM00 A RG BM10 RG BM Receiver A RG BN01 A RG BN11 RG BN Emitter A RG BN00 A RG BN10 RG BN Receiver A RG BP01 A RG BP11 RG BP Emitter A RG BP00 A RG BP10 RG BP20 0 resolution 150 Receiver A RG DB01 RG DB Emitter A RG DB00 RG DB Receiver A RG DC01 A RG DC11 RG DC Emitter A RG DC00 A RG DC10 RG DC20 00 Receiver A RG DD01 A RG DD11 RG DD21 00 Emitter A RG DD00 A RG DD10 RG DD Receiver A RG DE01 A RG DE11 RG DE Emitter A RG DE00 A RG DE10 RG DE Receiver A RG DF01 A RG DF11 RG DF Emitter A RG DF00 A RG DF10 RG DF Receiver A RG DG01 A RG DG11 RG DG Emitter A RG DG00 A RG DG10 RG DG Receiver A RG DH01 A RG DH11 RG DH Emitter A RG DH00 A RG DH10 RG DH Receiver A RG DJ01 A RG DJ11 RG DJ Emitter A RG DJ00 A RG DJ10 RG DJ Receiver A RG DK01 A RG DK11 RG DK Emitter A RG DK00 A RG DK10 RG DK Receiver A RG DL01 A RG DL11 RG DL Emitter A RG DL00 A RG DL10 RG DL20 /44 Siemens FS

12 Protection Version Standard device Host device Guest device height 1500 Receiver A RG DM01 A RG DM11 RG DM Emitter A RG DM00 A RG DM10 RG DM Receiver A RG DN01 A RG DN11 RG DN Emitter A RG DN00 A RG DN10 RG DN Receiver A RG DP01 A RG DP11 RG DP Emitter A RG DP00 A RG DP10 RG DP20 50 resolution 450 Receiver A RG EE01 A RG EE11 RG EE Emitter A RG EE00 A RG EE10 RG EE Receiver A RG EF01 A RG EF11 RG EF Emitter A RG EF00 A RG EF10 RG EF Receiver A RG EG01 A RG EG11 RG EG Emitter A RG EG00 A RG EG10 RG EG Receiver A RG EH01 A RG EH11 RG EH Emitter A RG EH00 A RG EH10 RG EH Receiver A RG EJ01 A RG EJ11 RG EJ Emitter A RG EJ00 A RG EJ10 RG EJ Receiver A RG EK01 A RG EK11 RG EK Emitter A RG EK00 A RG EK10 RG EK Receiver A RG EL01 A RG EL11 RG EL Emitter A RG EL00 A RG EL10 RG EL Receiver A RG EM01 A RG EM11 RG EM Emitter A RG EM00 A RG EM10 RG EM Receiver A RG EN01 A RG EN11 RG EN Emitter A RG EN00 A RG EN10 RG EN Receiver A RG EP01 A RG EP11 RG EP Emitter A RG EP00 A RG EP10 RG EP Receiver A RG ER01 A RG ER11 RG ER Emitter A RG ER00 A RG ER10 RG ER Receiver A RG ES01 A RG ES11 RG ES Emitter A RG ES00 A RG ES10 RG ES Receiver A RG ET01 A RG ET11 RG ET Emitter A RG ET00 A RG ET10 RG ET Receiver A RG EU01 A RG EU11 RG EU Emitter A RG EU00 A RG EU10 RG EU20 90 resolution 750 Receiver A RG JG01 A RG JG11 RG JG Emitter A RG JG00 A RG JG10 RG JG Receiver A RG JH01 A RG JH11 RG JH Emitter A RG JH00 A RG JH10 RG JH Receiver A RG JJ01 A RG JJ11 RG JJ Emitter A RG JJ00 A RG JJ10 RG JJ Receiver A RG JK01 A RG JK11 RG JK Emitter A RG JK00 A RG JK10 RG JK Receiver A RG JL01 A RG JL11 RG JL Emitter A RG JL00 A RG JL10 RG JL Receiver A RG JM01 A RG JM11 RG JM Emitter A RG JM00 A RG JM10 RG JM Receiver A RG JN01 A RG JN11 RG JN Emitter A RG JN00 A RG JN10 RG JN20 Siemens FS /45

13 Protection Version Standard device Host device Guest device height 1800 Receiver A RG JP01 A RG JP11 RG JP Emitter A RG JP00 A RG JP10 RG JP Receiver A RG JR01 A RG JR11 RG JR Emitter A RG JR00 A RG JR10 RG JR Receiver A RG JS01 A RG JS11 RG JS Emitter A RG JS00 A RG JS10 RG JS Receiver A RG JT01 A RG JT11 RG JT Emitter A RG JT00 A RG JT10 RG JT Receiver A RG JU01 A RG JU11 RG JU Emitter A RG JU00 A RG JU10 RG JU20 Light arrays with standard function package transistor output with cable gland N m range 4-beam 00 Receiver A RG MH01 4-beam 00 Emitter A RG MH00 -beam 400 Receiver A RG PG01 -beam 400 Emitter A RG PG00 2-beam 500 Receiver A RG SE01 2-beam 500 Emitter A RG SE m range 4-beam 00 Receiver A RG MH51 4-beam 00 Emitter A RG MH50 -beam 400 Receiver A RG PG51 -beam 400 Emitter A RG PG50 2-beam 500 Receiver A RG SE51 2-beam 500 Emitter A RG SE50 Transceiver with standard function package transistor output with cable gland N 6.5 m range 2-beam 500 Transceiver A RG TE01 Reflective mirror for transceiver RG TL /46 Siemens FS

14 + * % ) * % SIMATIC FS400 light curtains and arrays Dimensional drawings Standard RG78 45 light curtains and RG78 45 light arrays " $ Pg 9 sealing cap (receiver only, for local interface) A Height of protective field (see selection and ordering data) B Total length = protection field height A + 14 # 5 + $ " % # # RG78 45 light arrays, additional dimensions " " Additional dimensions for light arrays only: Type B () C () Beams RG M 1, RG P 1, RG S # 5 + $ " & # # Siemens FS /47

SAFETY LIGHT CURTAINS

SAFETY LIGHT CURTAINS SAFETY LIGHT CURTAINS Overview Safety Light Curtains with resolutions that can be reduced guarantee protection and tolerate work equipment in the protective field The Safety Light Curtains comply with

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output

More information

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector. Photoelectric Sensor with Built-in Amplifier Photoelectric Sensor with built-in amplifier is applicable to a wide variety of lines and ensures a longer sensing distance than any other model. User-friendly

More information

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm Characteristics XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm Complementary Detection system Kit composition [EAA] effective aperture angle Emission Main Range of product Product or

More information

BZT52H series. Single Zener diodes in a SOD123F package

BZT52H series. Single Zener diodes in a SOD123F package Rev. 3 7 December 2010 Product data sheet 1. Product profile 1.1 General description General-purpose Zener diodes in a SOD123F small and flat lead Surface-Mounted Device (SMD) plastic package. 1.2 Features

More information

Manpower Codes Lookup

Manpower Codes Lookup 00 NO PREFERENCE RECORDED 01 NO RELIGIOUS PREFERENCE 02 SEVENTH-DAY ADVENTIST 04 ASSEMBLIES OF GOD 05 GRACE GOSPEL FELLOWSHIP 06 AMERICAN BAPTIST CHURCHES 07 INDEPENDENT BAPTIST BIBLE MISSION 08 SOUTHERN

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Barcode Reader Series BCL 31, BCL 32, BCL 34

Barcode Reader Series BCL 31, BCL 32, BCL 34 P R O D U C T I N F O R M A T I O N Barcode Reader Series BCL 31, BCL 32, BCL 34 BCL 31, BCL 32 and BCL 34: Barcode readers for universal use in conveyor and storage technology. 3 models: numerous advantages.

More information

W150: Miniature photoelectric switch series with completely integrated electronics

W150: Miniature photoelectric switch series with completely integrated electronics Product group W50 Photoelectric proximity switch BGS Photoelectric proximity switch energ. Photoelectric reflex switch W50: iniature photoelectric switch series with completely integrated electronics Through-beam

More information

Victims Compensation Claim Status of All Pending Claims and Claims Decided Within the Last Three Years

Victims Compensation Claim Status of All Pending Claims and Claims Decided Within the Last Three Years Claim#:021914-174 Initials: J.T. Last4SSN: 6996 DOB: 5/3/1970 Crime Date: 4/30/2013 Status: Claim is currently under review. Decision expected within 7 days Claim#:041715-334 Initials: M.S. Last4SSN: 2957

More information

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS MSI-s/R, MSI-sx/Rx Configurable MSI provide important functions for the efficient flow of automated production processes Special features Combined guarding types by connecting up to 4 AOPDs Additional

More information

MULTI-BEAM LS10 Light Screen System

MULTI-BEAM LS10 Light Screen System For Sensing Small Parts at High Speeds Emitter and receiver pair produce a strobed array of modulated light beams to produce a light screen Simple, economical and highly reliable means of sensing small

More information

Preset Counter signo 721

Preset Counter signo 721 Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage

More information

Future Trends in Airline Pricing, Yield. March 13, 2013

Future Trends in Airline Pricing, Yield. March 13, 2013 Future Trends in Airline Pricing, Yield Management, &AncillaryFees March 13, 2013 THE OPPORTUNITY IS NOW FOR CORPORATE TRAVEL MANAGEMENT BUT FIRST: YOU HAVE TO KNOCK DOWN BARRIERS! but it won t hurt much!

More information

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity Photoelectric Sensor with Built-in Amplifier Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity H Photo-IC provides long sensing distance: 15 m for through-beam, 4 m for retroreflective,

More information

Electronic Pressure Switch EDS 300

Electronic Pressure Switch EDS 300 Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

The consensus of the Pharmacy Practice Model Summit Am J Health-Syst Pharm. 2011; 68:1148-52 This list of the Pharmacy Practice

The consensus of the Pharmacy Practice Model Summit Am J Health-Syst Pharm. 2011; 68:1148-52 This list of the Pharmacy Practice The consensus of the summit The consensus of the Pharmacy Practice Model Summit Am J Health-Syst Pharm. 2011; 68:1148-52 This list of the Pharmacy Practice Model Summit s 147 points of consensus about

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

Adjustment functions for both span and shift have been incorporated

Adjustment functions for both span and shift have been incorporated SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

T360 Barbecue. Assembly Manual. 85-3052-6 (G30531) Propane 1 YEAR LIMITED WARRANTY

T360 Barbecue. Assembly Manual. 85-3052-6 (G30531) Propane 1 YEAR LIMITED WARRANTY T360 Barbecue Assembly Manual 85-3052-6 (G30531) Propane 1 YEAR LIMITED WARRANTY READ AND SAVE MANUAL FOR FUTURE REFERENCE. If pre-assembled, leave this manual with unit for consumer s future reference.

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output. Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6

More information

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049

More information

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up

More information

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur. egment Protector for Cabinet nstallation Features Assembly 4... 12 outputs Ex ic (FCO or Entity) or non-incendive (Div 2) Advanced fault isolation at the spur egment Protector in Zone 2/Div. 2 nstruments

More information

W 27-2: The photoelectric switch series with expanded possibilities

W 27-2: The photoelectric switch series with expanded possibilities W - Photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W -: The photoelectric switch series with expanded possibilities metres

More information

Conductive Level Switch FK 2 Technical Data:

Conductive Level Switch FK 2 Technical Data: Level switch for conductive liquids Optional electrode length adjustment Hygienic installation in accordance with EHEDG Wetted parts compatible with FDA requirements Potted electronic Not influenced by

More information

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Analog value representation

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

g9sp Programmable Safety controllers compact Stand-Alone Programmable controller NEW! example of System configuration G9SP

g9sp Programmable Safety controllers compact Stand-Alone Programmable controller NEW! example of System configuration G9SP Programmable Safety controllers g9sp G9SP compact Stand-Alone Programmable controller Stand-alone safety controller for small and mid-sized machinery Easy programming for complex safety control Three types

More information

W 36: Mastering complex tasks reliably

W 36: Mastering complex tasks reliably Lichtschranken W Photoelectric Baureihe switches WL - Photoelectric proximity switches, BGS Photoelectric reflex switches W : astering complex tasks reliably Through-beam photoelectric switches for temperatures

More information

6ES7 313-6BE01-0AB0 6ES7 313-5BE01-0AB0

6ES7 313-6BE01-0AB0 6ES7 313-5BE01-0AB0 4 SIMATIC S7-300 Central processing units CPU 312C to CPU 317F-2 DP CPU 317F-2 DP The failsafe CPU with a large program memory and quantity framework for demanding applications For configuration of a failsaf

More information

DS 600. A contact free flux gate based current measurement sensor 600A rms

DS 600. A contact free flux gate based current measurement sensor 600A rms DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum

More information

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male

More information

W 260: Standard photoelectric switch series for a broad range of applications

W 260: Standard photoelectric switch series for a broad range of applications W 0 Photoelectric switches Photoelectric proximity switches, BGS Photoelectric proximity switches, energetic Photoelectric reflex switches W 0: Standard photoelectric switch series for a broad range of

More information

Barcode positioning systems BPS 8, BPS 34/37 Innovations that truly move you forwards.

Barcode positioning systems BPS 8, BPS 34/37 Innovations that truly move you forwards. Barcode positioning systems BPS 8, BPS 34/37 Innovations that truly move you forwards. PRODUCT INFORMATION Flexible, tolerant and millimetre precision. The Leuze electronic barcode positioning system.

More information

Universal Voltage Terminal Photoelectric E3JM

Universal Voltage Terminal Photoelectric E3JM Universal Voltage Terminal Photoelectric Universal AC/DC Photoelectric Sensor with Built-in Timer Easy-to-wire terminal block Built-in timer offers selectable ON-delay, OFF-delay and one-shot Relay or

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute

More information

TECHNICAL DATASHEET Incremental Encoder RI 58-H

TECHNICAL DATASHEET Incremental Encoder RI 58-H Through hollow shaft High accuracy by means of integrated flexible coupling Safe shaft mounting Applications: textile machines, motors, drives, copiers NUMBER OF PULSES 1 / 2 / 3 / 4 / 5 / 10 / 15 / 20

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M. Inductive sensor, IE series, IE08, DC-wire, Standard series, Flush Inductive sensor Sensing range.5 mm Short-circuit protection (pulsed) Dimensional drawing 8x Robust brass housing, nickelplated with fine

More information

Color Mark Sensor with Red or Green LED E3S-VS

Color Mark Sensor with Red or Green LED E3S-VS Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical

More information

Electronic Pressure Switch EDS 3000

Electronic Pressure Switch EDS 3000 For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or

More information

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications Bar Code Reader Series BCL 20 A flexible reader for a variety of applications PRODUCT INFORMATION The benchmark for flexibility. Laser scanners of the BCL 20 series as variable as your requirements demand.

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

Safety Light Curtains. We make safety easy.

Safety Light Curtains. We make safety easy. Safety Light Curtains. We make safety easy. When Safety Matters, We ve got you covered. TR Electronic is an industry leader in manufacturing and supporting a complete line of absolute rotary encoders,

More information

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular

More information

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall

More information

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.

More information

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A 6ES7313-5BF03-0AB0 Page 1 Product data sheet 6ES7313-5BF03-0AB0 SIMATIC S7-300, CPU 313C, COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO 1 PT100, 3 FAST COUNTERS (30 KHZ), INTEGRATED 24V DC POWER SUPPLY,

More information

Option field bus: without bus with profibus DP. Design-Index (Subject to change)

Option field bus: without bus with profibus DP. Design-Index (Subject to change) Amplifier / controller cards ED1 Digital amplifier / controller card ED1 for 1 or 2 proportional solenoids 4 analogue inputs, of which 2 for differential inputs 8 digital inputs Card setting via PC, multi-function

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS Online data sheet PET-1CB010N10SVMC PET B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Pressure type Measuring range Ordering information Other models and

More information

Digital Expansion Modules Specifications

Digital Expansion Modules Specifications S7200 Programmable Controller System anual Digital Expansion odules Specifications Table A11 Digital Expansion odules Order umbers Order umber Expansion odel Digital Inputs Digital Outputs Removable Connector

More information

EGSTON Standard E2xFxWx 12W

EGSTON Standard E2xFxWx 12W General description The family of switchmode power supplies offers an unmatched degree of flexibility and performance fulfilling even the most stringent requirements. Highly flexible electrical configuration

More information

DATING YOUR GUILD 1952-1960

DATING YOUR GUILD 1952-1960 DATING YOUR GUILD 1952-1960 YEAR APPROXIMATE LAST SERIAL NUMBER PRODUCED 1953 1000-1500 1954 1500-2200 1955 2200-3000 1956 3000-4000 1957 4000-5700 1958 5700-8300 1959 12035 1960-1969 This chart displays

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar. CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension

More information

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series Programmable Terminal NPSeries Easy Setup with the Low-cost, Compact NP Series Simpler and More Versatile.OMRON s Compact NP Series Connect! Easier connection to OMRON PLCs and Temperature Controllers,

More information

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology Tilt switches MEMS technology, one or two axis N3 / N4... + long lifetime and highly reliability due to mechanism-free MEMS technology + combinable output signals + one or two axis measurement + tilt range

More information

LCM Design Engineering SPECIFICATION FOR LCD MODULE TYPE ITEM NO.: MDLS16265-04 MDLS16265-LV-G-LED04G (BB) (DOC. REVISION 1.0)

LCM Design Engineering SPECIFICATION FOR LCD MODULE TYPE ITEM NO.: MDLS16265-04 MDLS16265-LV-G-LED04G (BB) (DOC. REVISION 1.0) VARITRONIX LIMITED LCM Design Engineering SPECIFICATION FOR LCD MODULE TYPE ITEM NO.: MDLS16265-04 MDLS16265-LV-G-LED04G (BB) (DOC. REVISION 1.0) DEPARTMENT NAME SIGNATURE EFFECTIVE DATE PREPARED BY PHILIP

More information

Vehicle Identification Numbering System 00.03

Vehicle Identification Numbering System 00.03 Vehicle Identification Numbering System 00.03 IMPORTANT: See Subject 050 for the vehicle identification numbering system for vehicles built before May 1, 2000. Federal Motor Vehicle Safety Standard 115

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED) NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate

More information

is then retained absolutely without interruption.

is then retained absolutely without interruption. Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection

More information

Transient Voltage Suppressor SMBJ5.0 - SMBJ440CA

Transient Voltage Suppressor SMBJ5.0 - SMBJ440CA Features: Glass passivated junction Low incremental surge resistance, excellent clamping capability 600W peak pulse power capability with a 10/1,000μs waveform, repetition rate (duty cycle): 0.01% Very

More information

NX safety stand-alone

NX safety stand-alone NX-S@ NX safety stand-alone stand-alone into machine automation Expandable safety system up to 32 safety connections or 63 standard connections controller flexible system lets your freely mix safety I/O

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm Model Number Features Increased operating distance 8 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications

More information

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA w VOLTAGE MONITORING RELAY UR5U1011 w SCHRACK-INFO AC/DC voltage monitoring in 1-phase mains Undervoltage monitoring 1 change over contact Width 17.5 mm Installation design w TECHNICAL DATA 502 1. Functions

More information

Plug-in relays Mini ISO relays

Plug-in relays Mini ISO relays Powertrain Systems Chassis Systems Safety Security Body Driver Information Convenience Description Features Limiting continuous current 70 A Dimensional characteristics and the functional allocation of

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

SINEAX U553 Transducer for AC Voltage

SINEAX U553 Transducer for AC Voltage With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load

More information

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection Specifications and description Leuze electronic LS 78 Throughbeam photoelectric sensors Dimensioned drawing 180m 10-30 V DC! Voltage range from 12 30VDC with NPN, PNP and/or relay outputs! Light/dark switching!

More information

DISCRETE SEMICONDUCTORS DATA SHEET. BZX384 series Voltage regulator diodes. Product data sheet Supersedes data of 2003 Apr 01.

DISCRETE SEMICONDUCTORS DATA SHEET. BZX384 series Voltage regulator diodes. Product data sheet Supersedes data of 2003 Apr 01. DISCRETE SEMICONDUCTORS DATA SHEET Supersedes data of 2003 Apr 01 2004 Mar 22 FEATURES Total power dissipation: max. 300 mw Two tolerance series: ±2% and approx. ±5% Working voltage range: nominal 2.4

More information

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2 Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened

More information

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS MSI-m/R, MSI-mx/Rx Configurable MSI Safety Relay with function for efficient material flow in a packaging application Special features Sequential or Parallel with automatic mode detection MSI-mx for separate

More information

My first Hirschmann: The SPIDER family of switches.

My first Hirschmann: The SPIDER family of switches. My first Hirschmann: The SPIDER family of switches. Large selection of entry level switches Compact design Simple rail installation Industry standard 24 V supply voltage Plug & Play gets you up and running

More information

BOS 73K... BOS 74K...

BOS 73K... BOS 74K... BFB/BOS When there s no space for a photoelectric sensor, there is only one solution: user fiber optics! If there are no particular demands for toughness an ambient temperature or chemical resistance,

More information

How To Make An Ultrasonic Sensor

How To Make An Ultrasonic Sensor crm+ ultrasonic sensors Microsonic : TR Electronic: Tel: +49 231 975151-0 USA: 248-244-2280 Fax: +49 231 975151-51 Canada: 519-452-1233 www.microsonic.de www.trelectronic.com info@microsonic.de Description

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval series Light Curtain Sensors New type with radial cross ray method Small objects and flat tape-like objects detected Convenient simplified wiring requiring no clock (synchronization) line Compact and flat

More information

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment

More information

intelligent solutions

intelligent solutions Lichtschranken W 8- Photoelectric Baureihe switches WL - Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W 8-: Integrated stateof-the-art technology

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

Floodlight Range Installation Guide

Floodlight Range Installation Guide SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected

More information

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:

More information

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4 Cable max. 50 m between interface and read/write head Connection of up to 4 read/write heads via BL ident extension cables Mixed operation of HF and UHF read/ write heads Connectors /S2500 Type code Ident

More information