3 3RG78 45 program overview

Size: px
Start display at page:

Download "3 3RG78 45 program overview"

Transcription

1 Overview RG78 45 light curtains and arrays with integrated processing unit for type 4 in accordance with IEC/EN With "Standard" function package Resolutions: 14, 0, 50, and 90 Protective zone height: 150 to beam, -beam or 4-beam light arrays Cascading of host and guest devices for greater protective zone heights or lengths or for an angular arrangement (optional). Two standard RG AB mounting brackets each are enclosed with all devices (can also be ordered as accessories). RG78 45 program overview Unit type Function package Output Connection type For light curtains: Resolution For light arrays and transceivers: Range Light curtains N Standard Transistor M12 plug connector /6 Light arrays N Standard Transistor M12 plug connector 0.8 m to 18 m; 6 to 60 m /8 Transceiver N Standard Transistor M12 plug connector 6.5 m /8 Light curtains N Standard Transistor Hirschmann /9 Light arrays N Standard Transistor Hirschmann 0.8 m to 18 m; 6 to 60 m /40 Transceiver N Standard Transistor Hirschmann 6.5 m /40 Light curtains N Standard Transistor Brad Harrison (MIN) 1) /41 Light arrays N Standard Transistor Brad Harrison (MIN) 1) 0.8 m to 18 m; 6 to 60 m /4 Transceiver N Standard Transistor Brad Harrison (MIN) 1) 6.5 m /4 Light curtains N Standard Transistor Cable gland /44 Light arrays N Standard Transistor Cable gland 0.8 m to 18 m; 6 to 60 m /46 Transceiver N Standard Transistor Cable gland 6.5 m /46 Accessories Electrical connection Hirschmann type cables and cable plugs /85 Brad-Harrison type cable (MIN series) /85 Connecting cable with M12 connection /86 Assembly materials Fixing columns, reflecting mirror /8 Muting mounting systems /84 Muting accessories /86 Laser alignment aids, diagnostic software /84 see Page 1) Required primarily for applications in the NAFTA market /4 Siemens FS

2 Technical specifications Type RG78 45 Safety category to Type 4 (self-monitoring) EN, IEC , - Detection capability (resolution) 14, 0, 50, 90 or whole person with 2, or 4 beams Protective field height for 14 and 0 resolution for 50 resolution for 90 resolution Protective field width, sensing field for 14 resolution m for 0, 50 and 90 resolution m for 18 m light array m for 60 m light array m Supply voltage (emitter and receiver) Current consumption Emitter Receiver Vibration resistance Shock resistance Infrared stray light suppression Standard d-scan Synchronization between emitter and receiver Ambient temperature 24 V DC ± 20% (external power pack with safe isolation and 20 ms voltage power loss ride-through) 75 ma 180 ma (without external load) 5 g, Hz to IEC/EN g, 16 ms to IEC/EN procedures may be selected High suppression Very high suppression (response time increases in units with more than 15 beams) Optical; 2 transmission channels can be selected Operation C Storage C Humidity % Type of protection IP65 Electrical connection via Pg 1 screw-type terminals and pluggable wiring space Connecting cable Emitter 7-pin: Receiver 7-pin: (shielded, if necessary) Cable length for m Inputs Emitter test input Minimum opening duration Closed-circuit principle 50 ms Outputs Safety outputs 2 failsafe pnp outputs with cross-circuit monitoring (short circuit proof) Output voltage U a min U vers 2.7 V Output current I a max 0. A Peak current 0.4 A Continuous current at 5 C 0. A at 55 C 0.22 A Max. load capacity per output 00 nf (100 nf at channel 2) Response time from the protective field interrupt to disconnection of the safety outputs Increases with higher number of beams for 14 resolution ms (d-scan ms) for 0 resolution ms (d-scan ms) for 50 resolution 17 ms (d-scan ms) for 90 resolution 1 ms (d-scan 20 ms) for 2,, or 4-beam light arrays 5 ms (d-scan 8 ms) Reactivation time from release of the protective field to connection of the safety outputs For all resolutions 0.5 ms After very brief protective 100 ms field interrupts Pollution and error message output pnp output, short circuit proof Output current, max. 70 ma Safety and diagnostic interfaces RS485, 57.6 kbaud Siemens FS /5

3 Selection and Ordering Data Light curtains with standard function package transistor output with M12 plug connector N Protection Version Standard device Host device Guest device height 14 resolution 150 Receiver A RG78 45-BB01 RG BB Emitter A RG78 45-BB00 RG BB Receiver A RG78 45-BC01 A RG78 45-BC11 RG BC Emitter A RG78 45-BC00 A RG78 45-BC10 RG BC20 00 Receiver A RG78 45-BD01 A RG78 45-BD11 RG BD21 00 Emitter A RG78 45-BD00 A RG78 45-BD10 RG BD Receiver A RG78 45-BE01 A RG78 45-BE11 RG BE Emitter A RG78 45-BE00 A RG78 45-BE10 RG BE Receiver A RG78 45-BF01 A RG78 45-BF11 RG BF Emitter A RG78 45-BF00 A RG78 45-BF10 RG BF Receiver A RG78 45-BG01 A RG78 45-BG11 RG BG Emitter A RG78 45-BG00 A RG78 45-BG10 RG BG Receiver A RG78 45-BH01 A RG78 45-BH11 RG BH Emitter A RG78 45-BH00 A RG78 45-BH10 RG BH Receiver A RG78 45-BJ01 A RG78 45-BJ11 RG BJ Emitter A RG78 45-BJ00 A RG78 45-BJ10 RG BJ Receiver A RG78 45-BK01 A RG78 45-BK11 RG BK Emitter A RG78 45-BK00 A RG78 45-BK10 RG BK Receiver A RG78 45-BL01 A RG78 45-BL11 RG BL Emitter A RG78 45-BL00 A RG78 45-BL10 RG BL Receiver A RG78 45-BM01 A RG78 45-BM11 RG BM Emitter A RG78 45-BM00 A RG78 45-BM10 RG BM Receiver A RG78 45-BN01 A RG78 45-BN11 RG BN Emitter A RG78 45-BN00 A RG78 45-BN10 RG BN Receiver A RG78 45-BP01 A RG78 45-BP11 RG BP Emitter A RG78 45-BP00 A RG78 45-BP10 RG BP20 0 resolution 150 Receiver A RG78 45-DB01 RG DB Emitter A RG78 45-DB00 RG DB Receiver A RG78 45-DC01 A RG78 45-DC11 RG DC Emitter A RG78 45-DC00 A RG78 45-DC10 RG DC20 00 Receiver A RG78 45-DD01 A RG78 45-DD11 RG DD21 00 Emitter A RG78 45-DD00 A RG78 45-DD10 RG DD Receiver A RG78 45-DE01 A RG78 45-DE11 RG DE Emitter A RG78 45-DE00 A RG78 45-DE10 RG DE Receiver A RG78 45-DF01 A RG78 45-DF11 RG DF Emitter A RG78 45-DF00 A RG78 45-DF10 RG DF Receiver A RG78 45-DG01 A RG78 45-DG11 RG DG Emitter A RG78 45-DG00 A RG78 45-DG10 RG DG Receiver A RG78 45-DH01 A RG78 45-DH11 RG DH Emitter A RG78 45-DH00 A RG78 45-DH10 RG DH Receiver A RG78 45-DJ01 A RG78 45-DJ11 RG DJ Emitter A RG78 45-DJ00 A RG78 45-DJ10 RG DJ Receiver A RG78 45-DK01 A RG78 45-DK11 RG DK Emitter A RG78 45-DK00 A RG78 45-DK10 RG DK20 /6 Siemens FS

4 Protection Version Standard device Host device Guest device height 150 Receiver A RG78 45-DL01 A RG78 45-DL11 RG DL Emitter RG78 45-DL00 A RG78 45-DL10 RG DL Receiver A RG78 45-DM01 A RG78 45-DM11 RG DM Emitter A RG78 45-DM00 A RG78 45-DM10 RG DM Receiver A RG78 45-DN01 A RG78 45-DN11 RG DN Emitter A RG78 45-DN00 A RG78 45-DN10 RG DN Receiver A RG78 45-DP01 A RG78 45-DP11 RG DP Emitter A RG78 45-DP00 A RG78 45-DP10 RG DP20 50 resolution 450 Receiver A RG78 45-EE01 A RG78 45-EE11 RG EE Emitter A RG78 45-EE00 A RG78 45-EE10 RG EE Receiver A RG78 45-EF01 A RG78 45-EF11 RG EF Emitter A RG78 45-EF00 A RG78 45-EF10 RG EF Receiver A RG78 45-EG01 A RG78 45-EG11 RG EG Emitter A RG78 45-EG00 A RG78 45-EG10 RG EG Receiver A RG78 45-EH01 A RG78 45-EH11 RG EH Emitter A RG78 45-EH00 A RG78 45-EH10 RG EH Receiver A RG78 45-EJ01 A RG78 45-EJ11 RG EJ Emitter A RG78 45-EJ00 A RG78 45-EJ10 RG EJ Receiver A RG78 45-EK01 A RG78 45-EK11 RG EK Emitter A RG78 45-EK00 A RG78 45-EK10 RG EK Receiver A RG78 45-EL01 A RG78 45-EL11 RG EL Emitter A RG78 45-EL00 A RG78 45-EL10 RG EL Receiver A RG78 45-EM01 A RG78 45-EM11 RG EM Emitter A RG78 45-EM00 A RG78 45-EM10 RG EM Receiver A RG78 45-EN01 A RG78 45-EN11 RG EN Emitter A RG78 45-EN00 A RG78 45-EN10 RG EN Receiver A RG78 45-EP01 A RG78 45-EP11 RG EP Emitter A RG78 45-EP00 A RG78 45-EP10 RG EP Receiver A RG78 45-ER01 A RG78 45-ER11 RG ER Emitter A RG78 45-ER00 A RG78 45-ER10 RG ER Receiver A RG78 45-ES01 A RG78 45-ES11 RG ES Emitter A RG78 45-ES00 A RG78 45-ES10 RG ES Receiver A RG78 45-ET01 A RG78 45-ET11 RG ET Emitter A RG78 45-ET00 A RG78 45-ET10 RG ET Receiver A RG78 45-EU01 A RG78 45-EU11 RG EU Emitter A RG78 45-EU00 A RG78 45-EU10 RG EU20 90 resolution 750 Receiver A RG78 45-JG01 A RG78 45-JG11 RG JG Emitter A RG78 45-JG00 A RG78 45-JG10 RG JG Receiver A RG78 45-JH01 A RG78 45-JH11 RG JH Emitter A RG78 45-JH00 A RG78 45-JH10 RG JH Receiver A RG78 45-JJ01 A RG78 45-JJ11 RG JJ Emitter A RG78 45-JJ00 A RG78 45-JJ10 RG JJ Receiver A RG78 45-JK01 A RG78 45-JK11 RG JK Emitter A RG78 45-JK00 A RG78 45-JK10 RG JK Receiver A RG78 45-JL01 A RG78 45-JL11 RG JL Emitter A RG78 45-JL00 A RG78 45-JL10 RG JL Receiver A RG78 45-JM01 A RG78 45-JM11 RG JM Emitter A RG78 45-JM00 A RG78 45-JM10 RG JM20 Siemens FS /7

5 Protection Version Standard device Host device Guest device height 1650 Receiver A RG78 45-JN01 A RG78 45-JN11 RG JN Emitter A RG78 45-JN00 A RG78 45-JN10 RG JN Receiver A RG78 45-JP01 A RG78 45-JP11 RG JP Emitter A RG78 45-JP00 A RG78 45-JP10 RG JP Receiver A RG78 45-JR01 A RG78 45-JR11 RG JR Emitter A RG78 45-JR00 A RG78 45-JR10 RG JR Receiver A RG78 45-JS01 A RG78 45-JS11 RG JS Emitter A RG78 45-JS00 A RG78 45-JS10 RG JS Receiver A RG78 45-JT01 A RG78 45-JT11 RG JT Emitter A RG78 45-JT00 A RG78 45-JT10 RG JT Receiver A RG78 45-JU01 A RG78 45-JU11 RG JU Emitter A RG78 45-JU00 A RG78 45-JU10 RG JU20 Light arrays with standard function package transistor output with M12 plug connector N m range 4-beam 00 Receiver A RG78 45-MH01 4-beam 00 Emitter A RG78 45-MH00 -beam 400 Receiver A RG78 45-PG01 -beam 400 Emitter A RG78 45-PG00 2-beam 500 Receiver A RG78 45-SE01 2-beam 500 Emitter A RG78 45-SE m range 4-beam 00 Receiver A RG78 45-MH51 4-beam 00 Emitter A RG78 45-MH50 -beam 400 Receiver A RG78 45-PG51 -beam 400 Emitter A RG78 45-PG50 2-beam 500 Receiver A RG78 45-SE51 2-beam 500 Emitter A RG78 45-SE50 Transceiver with standard function package transistor output with M12 plug connector N 6.5 m range 2-beam 500 Transceiver A RG78 45-TE01 Reflective mirror for transceiver RG TL /8 Siemens FS

6 Light curtains with standard function package transistor output with Hirschmann plug connector N SIMATIC FS400 light curtains and arrays Protection height Version Standard device Host device Guest device 14 resolution 150 Receiver A RG BB01 RG BB Emitter A RG BB00 RG BB Receiver A RG BC01 On request RG BC Emitter A RG BC00 On request RG BC20 00 Receiver A RG BD01 On request RG BD21 00 Emitter A RG BD00 On request RG BD Receiver A RG BE01 On request RG BE Emitter A RG BE00 On request RG BE Receiver A RG BF01 On request RG BF Emitter A RG BF00 On request RG BF Receiver A RG BG01 On request RG BG Emitter A RG BG00 On request RG BG Receiver A RG BH01 On request RG BH Emitter A RG BH00 On request RG BH Receiver A RG BJ01 On request RG BJ Emitter A RG BJ00 On request RG BJ Receiver A RG BK01 On request RG BK Emitter A RG BK00 On request RG BK Receiver A RG BL01 On request RG BL Emitter A RG BL00 On request RG BL Receiver A RG BM01 On request RG BM Emitter A RG BM00 On request RG BM Receiver A RG BN01 On request RG BN Emitter A RG BN00 On request RG BN Receiver A RG BP01 On request RG BP Emitter A RG BP00 On request RG BP20 0 resolution 150 Receiver A RG DB01 RG DB Emitter A RG DB00 RG DB Receiver A RG DC01 On request RG DC Emitter A RG DC00 On request RG DC20 00 Receiver A RG DD01 On request RG DD21 00 Emitter A RG DD00 On request RG DD Receiver A RG DE01 On request RG DE Emitter A RG DE00 On request RG DE Receiver A RG DF01 On request RG DF Emitter A RG DF00 On request RG DF Receiver A RG DG01 On request RG DG Emitter A RG DG00 On request RG DG Receiver A RG DH01 On request RG DH Emitter A RG DH00 On request RG DH Receiver A RG DJ01 On request RG DJ Emitter A RG DJ00 On request RG DJ Receiver A RG DK01 On request RG DK Emitter A RG DK00 On request RG DK Receiver A RG DL01 On request RG DL Emitter A RG DL00 On request RG DL20 Siemens FS /9

7 Protection height Version Standard device Host device Guest device 1500 Receiver A RG DM01 On request RG DM Emitter A RG DM00 On request RG DM Receiver A RG DN01 On request On request 1650 Emitter A RG DN00 On request On request 1800 Receiver A RG DP01 On request On request 1800 Emitter A RG DP00 On request On request Light arrays with standard function package transistor output with Hirschmann plug connector N m range 4-beam 00 Receiver A RG MH01 4-beam 00 Emitter A RG MH00 -beam 400 Receiver A RG PG01 -beam 400 Emitter A RG PG00 2-beam 500 Receiver A RG SE01 2-beam 500 Emitter A RG SE m range 4-beam 00 Receiver A RG MH51 4-beam 00 Emitter A RG MH50 -beam 400 Receiver A RG PG51 -beam 400 Emitter A RG PG50 2-beam 500 Receiver A RG SE51 2-beam 500 Emitter A RG SE50 Transceiver with Standard function package transistor output with Hirschmann plug connector N 6.5 m range 2-beam 500 Transceiver A RG TE01 Reflective mirror for transceiver RG TL /40 Siemens FS

8 Light curtains with standard function package transistor output with Brad Harrison connection (MIN-Series) 1) N SIMATIC FS400 light curtains and arrays Protection height Version Standard device Host device Guest device 14 resolution 150 Receiver A RG BB01 A RG BB Emitter A RG BB00 A RG BB Receiver A RG BC01 A RG BC11 RG BC Emitter A RG BC00 A RG BC10 RG BC20 00 Receiver A RG BD01 A RG BD11 RG BD21 00 Emitter A RG BD00 A RG BD10 RG BD Receiver A RG BE01 A RG BE11 RG BE Emitter A RG BE00 A RG BE10 RG BE Receiver A RG BF01 A RG BF11 RG BF Emitter A RG BF00 A RG BF10 RG BF Receiver A RG BG01 A RG BG11 RG BG Emitter A RG BG00 A RG BG10 RG BG Receiver A RG BH01 A RG BH11 RG BH Emitter A RG BH00 A RG BH10 RG BH Receiver A RG BJ01 A RG BJ11 RG BJ Emitter A RG BJ00 A RG BJ10 RG BJ Receiver A RG BK01 A RG BK11 RG BK Emitter A RG BK00 A RG BK10 RG BK Receiver A RG BL01 A RG BL11 RG BL Emitter A RG BL00 A RG BL10 RG BL Receiver A RG BM01 A RG BM11 RG BM Emitter A RG BM00 A RG BM10 RG BM Receiver A RG BN01 A RG BN11 RG BN Emitter A RG BN00 A RG BN10 RG BN Receiver A RG BP01 A RG BP11 RG BP Emitter A RG BP00 A RG BP10 RG BP20 0 resolution 150 Receiver A RG DB01 A RG DB Emitter A RG DB00 A RG DB Receiver A RG DC01 A RG DC11 RG DC Emitter A RG DC00 A RG DC10 RG DC20 00 Receiver A RG DD01 A RG DD11 RG DD21 00 Emitter A RG DD00 A RG DD10 RG DD Receiver A RG DE01 A RG DE11 RG DE Emitter A RG DE00 A RG DE10 RG DE Receiver A RG DF01 A RG DF11 RG DF Emitter A RG DF00 A RG DF10 RG DF Receiver A RG DG01 A RG DG11 RG DG Emitter A RG DG00 A RG DG10 RG DG Receiver A RG DH01 A RG DH11 RG DH Emitter A RG DH00 A RG DH10 RG DH Receiver A RG DJ01 A RG DJ11 RG DJ Emitter A RG DJ00 A RG DJ10 RG DJ Receiver A RG DK01 A RG DK11 RG DK Emitter A RG DK00 A RG DK10 RG DK Receiver A RG DL01 A RG DL11 RG DL Emitter A RG DL00 A RG DL10 RG DL20 1) Required primarily for applications in the NAFTA market Siemens FS /41

9 Protection height Version Standard device Host device Guest device 1500 Receiver A RG DM01 A RG DM11 RG DM Emitter A RG DM00 A RG DM10 RG DM Receiver A RG DN01 A RG DN11 RG DN Emitter A RG DN00 A RG DN10 RG DN Receiver A RG DP01 A RG DP11 RG DP Emitter A RG DP00 A RG DP10 RG DP20 50 resolution 450 Receiver A RG EE01 A RG EE11 RG EE Emitter A RG EE00 A RG EE10 RG EE Receiver A RG EF01 A RG EF11 RG EF Emitter A RG EF00 A RG EF10 RG EF Receiver A RG EG01 A RG EG11 RG EG Emitter A RG EG00 A RG EG10 RG EG Receiver A RG EH01 A RG EH11 RG EH Emitter A RG EH00 A RG EH10 RG EH Receiver A RG EJ01 A RG EJ11 RG EJ Emitter A RG EJ00 A RG EJ10 RG EJ Receiver A RG EK01 A RG EK11 RG EK Emitter A RG EK00 A RG EK10 RG EK Receiver A RG EL01 A RG EL11 RG EL Emitter A RG EL00 A RG EL10 RG EL Receiver A RG EM01 A RG EM11 RG EM Emitter A RG EM00 A RG EM10 RG EM Receiver A RG EN01 A RG EN11 RG EN Emitter A RG EN00 A RG EN10 RG EN Receiver A RG EP01 A RG EP11 RG EP Emitter A RG EP00 A RG EP10 RG EP Receiver A RG ER01 A RG ER11 RG ER Emitter A RG ER00 A RG ER10 RG ER Receiver A RG ES01 A RG ES11 RG ES Emitter A RG ES00 A RG ES10 RG ES Receiver A RG ET01 A RG ET11 RG ET Emitter A RG ET00 A RG ET10 RG ET Receiver A RG EU01 A RG EU11 RG EU Emitter A RG EU00 A RG EU10 RG EU20 90 resolution 750 Receiver A RG JG01 A RG JG11 RG JG Emitter A RG JG00 A RG JG10 RG JG Receiver A RG JH01 A RG JH11 RG JH Emitter A RG JH00 A RG JH10 RG JH Receiver A RG JJ01 A RG JJ11 RG JJ Emitter A RG JJ00 A RG JJ10 RG JJ Receiver A RG JK01 A RG JK11 RG JK Emitter A RG JK00 A RG JK10 RG JK Receiver A RG JL01 A RG JL11 RG JL Emitter A RG JL00 A RG JL10 RG JL Receiver A RG JM01 A RG JM11 RG JM Emitter A RG JM00 A RG JM10 RG JM Receiver A RG JN01 A RG JN11 RG JN Emitter A RG JN00 A RG JN10 RG JN20 /42 Siemens FS

10 Protection height Version Standard device Host device Guest device 1800 Receiver A RG JP01 A RG JP11 RG JP Emitter A RG JP00 A RG JP10 RG JP Receiver A RG JR01 A RG JR11 RG JR Emitter A RG JR00 A RG JR10 RG JR Receiver A RG JS01 A RG JS11 RG JS Emitter A RG JS00 A RG JS10 RG JS Receiver A RG JT01 A RG JT11 RG JT Emitter A RG JT00 A RG JT10 RG JT Receiver A RG JU01 A RG JU11 RG JU Emitter A RG JU00 A RG JU10 RG JU20 Light arrays with standard function package transistor output with Brad Harrison connection (MIN-Series) 1) N m range 4-beam 00 Receiver A RG MH01 4-beam 00 Emitter A RG MH00 -beam 400 Receiver A RG PG01 -beam 400 Emitter A RG PG00 2-beam 500 Receiver A RG SE01 2-beam 500 Emitter A RG SE m range 4-beam 00 Receiver A RG MH51 4-beam 00 Emitter A RG MH50 -beam 400 Receiver A RG PG51 -beam 400 Emitter A RG PG50 2-beam 500 Receiver A RG SE51 2-beam 500 Emitter A RG SE50 Transceiver with standard function package transistor output with Brad Harrison connection (MIN-Series) 1) N 6.5 m range 2-beam 500 Transceiver A RG TE01 Reflective mirror for transceiver RG TL 1) Required primarily for applications in the NAFTA market Siemens FS /4

11 Light curtains with standard function package transistor output with cable gland N Protection Version Standard device Host device Guest device height 14 resolution 150 Receiver A RG BB01 RG BB Emitter A RG BB00 RG BB Receiver A RG BC01 A RG BC11 RG BC Emitter A RG BC00 A RG BC10 RG BC20 00 Receiver A RG BD01 A RG BD11 RG BD21 00 Emitter A RG BD00 A RG BD10 RG BD Receiver A RG BE01 A RG BE11 RG BE Emitter A RG BE00 A RG BE10 RG BE Receiver A RG BF01 A RG BF11 RG BF Emitter A RG BF00 A RG BF10 RG BF Receiver A RG BG01 A RG BG11 RG BG Emitter A RG BG00 A RG BG10 RG BG Receiver A RG BH01 A RG BH11 RG BH Emitter A RG BH00 A RG BH10 RG BH Receiver A RG BJ01 A RG BJ11 RG BJ Emitter A RG BJ00 A RG BJ10 RG BJ Receiver A RG BK01 A RG BK11 RG BK Emitter A RG BK00 A RG BK10 RG BK Receiver A RG BL01 A RG BL11 RG BL Emitter A RG BL00 A RG BL10 RG BL Receiver A RG BM01 A RG BM11 RG BM Emitter A RG BM00 A RG BM10 RG BM Receiver A RG BN01 A RG BN11 RG BN Emitter A RG BN00 A RG BN10 RG BN Receiver A RG BP01 A RG BP11 RG BP Emitter A RG BP00 A RG BP10 RG BP20 0 resolution 150 Receiver A RG DB01 RG DB Emitter A RG DB00 RG DB Receiver A RG DC01 A RG DC11 RG DC Emitter A RG DC00 A RG DC10 RG DC20 00 Receiver A RG DD01 A RG DD11 RG DD21 00 Emitter A RG DD00 A RG DD10 RG DD Receiver A RG DE01 A RG DE11 RG DE Emitter A RG DE00 A RG DE10 RG DE Receiver A RG DF01 A RG DF11 RG DF Emitter A RG DF00 A RG DF10 RG DF Receiver A RG DG01 A RG DG11 RG DG Emitter A RG DG00 A RG DG10 RG DG Receiver A RG DH01 A RG DH11 RG DH Emitter A RG DH00 A RG DH10 RG DH Receiver A RG DJ01 A RG DJ11 RG DJ Emitter A RG DJ00 A RG DJ10 RG DJ Receiver A RG DK01 A RG DK11 RG DK Emitter A RG DK00 A RG DK10 RG DK Receiver A RG DL01 A RG DL11 RG DL Emitter A RG DL00 A RG DL10 RG DL20 /44 Siemens FS

12 Protection Version Standard device Host device Guest device height 1500 Receiver A RG DM01 A RG DM11 RG DM Emitter A RG DM00 A RG DM10 RG DM Receiver A RG DN01 A RG DN11 RG DN Emitter A RG DN00 A RG DN10 RG DN Receiver A RG DP01 A RG DP11 RG DP Emitter A RG DP00 A RG DP10 RG DP20 50 resolution 450 Receiver A RG EE01 A RG EE11 RG EE Emitter A RG EE00 A RG EE10 RG EE Receiver A RG EF01 A RG EF11 RG EF Emitter A RG EF00 A RG EF10 RG EF Receiver A RG EG01 A RG EG11 RG EG Emitter A RG EG00 A RG EG10 RG EG Receiver A RG EH01 A RG EH11 RG EH Emitter A RG EH00 A RG EH10 RG EH Receiver A RG EJ01 A RG EJ11 RG EJ Emitter A RG EJ00 A RG EJ10 RG EJ Receiver A RG EK01 A RG EK11 RG EK Emitter A RG EK00 A RG EK10 RG EK Receiver A RG EL01 A RG EL11 RG EL Emitter A RG EL00 A RG EL10 RG EL Receiver A RG EM01 A RG EM11 RG EM Emitter A RG EM00 A RG EM10 RG EM Receiver A RG EN01 A RG EN11 RG EN Emitter A RG EN00 A RG EN10 RG EN Receiver A RG EP01 A RG EP11 RG EP Emitter A RG EP00 A RG EP10 RG EP Receiver A RG ER01 A RG ER11 RG ER Emitter A RG ER00 A RG ER10 RG ER Receiver A RG ES01 A RG ES11 RG ES Emitter A RG ES00 A RG ES10 RG ES Receiver A RG ET01 A RG ET11 RG ET Emitter A RG ET00 A RG ET10 RG ET Receiver A RG EU01 A RG EU11 RG EU Emitter A RG EU00 A RG EU10 RG EU20 90 resolution 750 Receiver A RG JG01 A RG JG11 RG JG Emitter A RG JG00 A RG JG10 RG JG Receiver A RG JH01 A RG JH11 RG JH Emitter A RG JH00 A RG JH10 RG JH Receiver A RG JJ01 A RG JJ11 RG JJ Emitter A RG JJ00 A RG JJ10 RG JJ Receiver A RG JK01 A RG JK11 RG JK Emitter A RG JK00 A RG JK10 RG JK Receiver A RG JL01 A RG JL11 RG JL Emitter A RG JL00 A RG JL10 RG JL Receiver A RG JM01 A RG JM11 RG JM Emitter A RG JM00 A RG JM10 RG JM Receiver A RG JN01 A RG JN11 RG JN Emitter A RG JN00 A RG JN10 RG JN20 Siemens FS /45

13 Protection Version Standard device Host device Guest device height 1800 Receiver A RG JP01 A RG JP11 RG JP Emitter A RG JP00 A RG JP10 RG JP Receiver A RG JR01 A RG JR11 RG JR Emitter A RG JR00 A RG JR10 RG JR Receiver A RG JS01 A RG JS11 RG JS Emitter A RG JS00 A RG JS10 RG JS Receiver A RG JT01 A RG JT11 RG JT Emitter A RG JT00 A RG JT10 RG JT Receiver A RG JU01 A RG JU11 RG JU Emitter A RG JU00 A RG JU10 RG JU20 Light arrays with standard function package transistor output with cable gland N m range 4-beam 00 Receiver A RG MH01 4-beam 00 Emitter A RG MH00 -beam 400 Receiver A RG PG01 -beam 400 Emitter A RG PG00 2-beam 500 Receiver A RG SE01 2-beam 500 Emitter A RG SE m range 4-beam 00 Receiver A RG MH51 4-beam 00 Emitter A RG MH50 -beam 400 Receiver A RG PG51 -beam 400 Emitter A RG PG50 2-beam 500 Receiver A RG SE51 2-beam 500 Emitter A RG SE50 Transceiver with standard function package transistor output with cable gland N 6.5 m range 2-beam 500 Transceiver A RG TE01 Reflective mirror for transceiver RG TL /46 Siemens FS

14 + * % ) * % SIMATIC FS400 light curtains and arrays Dimensional drawings Standard RG78 45 light curtains and RG78 45 light arrays " $ Pg 9 sealing cap (receiver only, for local interface) A Height of protective field (see selection and ordering data) B Total length = protection field height A + 14 # 5 + $ " % # # RG78 45 light arrays, additional dimensions " " Additional dimensions for light arrays only: Type B () C () Beams RG M 1, RG P 1, RG S # 5 + $ " & # # Siemens FS /47

SAFETY LIGHT CURTAINS

SAFETY LIGHT CURTAINS SAFETY LIGHT CURTAINS Overview Safety Light Curtains with resolutions that can be reduced guarantee protection and tolerate work equipment in the protective field The Safety Light Curtains comply with

More information

E3FS. Safety Photoelectric Switch. Safety design for category 2. Suitable for detecting human bodies in hazardous area.

E3FS. Safety Photoelectric Switch. Safety design for category 2. Suitable for detecting human bodies in hazardous area. Safety Photoelectric Switch Safety design for category 2. Suitable for detecting human bodies in hazardous area. ± Main features The is a Type 2 Safety Single Beam intended to be used with the control

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector. Photoelectric Sensor with Built-in Amplifier Photoelectric Sensor with built-in amplifier is applicable to a wide variety of lines and ensures a longer sensing distance than any other model. User-friendly

More information

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output

More information

Photoelectrics Through-beam Type PH18CNT..., DC

Photoelectrics Through-beam Type PH18CNT..., DC Photoelectrics Through-beam Type PH8CNT..., DC Miniature sensor range Range: 20 m Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: 0 to 0 VDC Output: 00 ma, NPN

More information

Manpower Codes Lookup

Manpower Codes Lookup 00 NO PREFERENCE RECORDED 01 NO RELIGIOUS PREFERENCE 02 SEVENTH-DAY ADVENTIST 04 ASSEMBLIES OF GOD 05 GRACE GOSPEL FELLOWSHIP 06 AMERICAN BAPTIST CHURCHES 07 INDEPENDENT BAPTIST BIBLE MISSION 08 SOUTHERN

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm Characteristics XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm Complementary Detection system Kit composition [EAA] effective aperture angle Emission Main Range of product Product or

More information

Barcode Reader Series BCL 31, BCL 32, BCL 34

Barcode Reader Series BCL 31, BCL 32, BCL 34 P R O D U C T I N F O R M A T I O N Barcode Reader Series BCL 31, BCL 32, BCL 34 BCL 31, BCL 32 and BCL 34: Barcode readers for universal use in conveyor and storage technology. 3 models: numerous advantages.

More information

BZT52H series. Single Zener diodes in a SOD123F package

BZT52H series. Single Zener diodes in a SOD123F package Rev. 3 7 December 2010 Product data sheet 1. Product profile 1.1 General description General-purpose Zener diodes in a SOD123F small and flat lead Surface-Mounted Device (SMD) plastic package. 1.2 Features

More information

MULTI-BEAM LS10 Light Screen System

MULTI-BEAM LS10 Light Screen System For Sensing Small Parts at High Speeds Emitter and receiver pair produce a strobed array of modulated light beams to produce a light screen Simple, economical and highly reliable means of sensing small

More information

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS MSI-s/R, MSI-sx/Rx Configurable MSI provide important functions for the efficient flow of automated production processes Special features Combined guarding types by connecting up to 4 AOPDs Additional

More information

W150: Miniature photoelectric switch series with completely integrated electronics

W150: Miniature photoelectric switch series with completely integrated electronics Product group W50 Photoelectric proximity switch BGS Photoelectric proximity switch energ. Photoelectric reflex switch W50: iniature photoelectric switch series with completely integrated electronics Through-beam

More information

Pressure transmitter (2 wire) / switch for continuous or On/Off Control

Pressure transmitter (2 wire) / switch for continuous or On/Off Control transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Programmable Relays. ZEN Series. ZEN Programmable Relays. Applications

Programmable Relays. ZEN Series. ZEN Programmable Relays. Applications Programmable Relays ZEN Series Relay, Timer, Counter, and Time Switch Functions Weekly Timer and Calendar Timer Functions Twin Timer Function (Separate ON/OFF Times) Two Analog Input Channels (DC Models

More information

Assembly. Front view. Switch S1. Power Rail

Assembly. Front view. Switch S1. Power Rail Temperature Repeater Features Assembly 1-channel isolated barrier V DC supply (Power Rail) Resistance and RTD input (Pt100, Pt500, Pt1000) Resistance output Accuracy 0.1 % Line fault detection (LFD) for

More information

Adjustment functions for both span and shift have been incorporated

Adjustment functions for both span and shift have been incorporated SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8

More information

Electronic Pressure Switch EDS 300

Electronic Pressure Switch EDS 300 Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5

More information

Preset Counter signo 721

Preset Counter signo 721 Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage

More information

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity Photoelectric Sensor with Built-in Amplifier Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity H Photo-IC provides long sensing distance: 15 m for through-beam, 4 m for retroreflective,

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

Measurement range. Protection class. Resolution 0.03 % ( ); 0.1 % ( ) Repeatability ±0.03 % ( ); ±0.1 % (15...

Measurement range. Protection class. Resolution 0.03 % ( ); 0.1 % ( ) Repeatability ±0.03 % ( ); ±0.1 % (15... Magnetic Angle Sensor with Analog Output Magnetic angle 0-360 Measurement range 0-360 Protection class IP60 Analog output Non-contact with external position magnet Wear free Compact, low profile housing

More information

Measurement range. Protection class. Resolution 0.03 % ( ); 0.1 % ( ) Repeatability ±0.03 % ( ); ±0.1 % (15...

Measurement range. Protection class. Resolution 0.03 % ( ); 0.1 % ( ) Repeatability ±0.03 % ( ); ±0.1 % (15... Magnetic Angle Sensor with Analog Output Magnetic angle 0-360 Measurement range 0-360 Protection class IP60 Analog output Non-contact with external position magnet Wear free Compact, low profile housing

More information

T360 Barbecue. Assembly Manual. 85-3052-6 (G30531) Propane 1 YEAR LIMITED WARRANTY

T360 Barbecue. Assembly Manual. 85-3052-6 (G30531) Propane 1 YEAR LIMITED WARRANTY T360 Barbecue Assembly Manual 85-3052-6 (G30531) Propane 1 YEAR LIMITED WARRANTY READ AND SAVE MANUAL FOR FUTURE REFERENCE. If pre-assembled, leave this manual with unit for consumer s future reference.

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

LONWORKS Fibre Optic Converter

LONWORKS Fibre Optic Converter LONWORKS Fiber Optic Converter LRW-102 and LRW-102/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-102 is a fibre optic modem designed for multidrop and redundant ring

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

Future Trends in Airline Pricing, Yield. March 13, 2013

Future Trends in Airline Pricing, Yield. March 13, 2013 Future Trends in Airline Pricing, Yield Management, &AncillaryFees March 13, 2013 THE OPPORTUNITY IS NOW FOR CORPORATE TRAVEL MANAGEMENT BUT FIRST: YOU HAVE TO KNOCK DOWN BARRIERS! but it won t hurt much!

More information

Victims Compensation Claim Status of All Pending Claims and Claims Decided Within the Last Three Years

Victims Compensation Claim Status of All Pending Claims and Claims Decided Within the Last Three Years Claim#:021914-174 Initials: J.T. Last4SSN: 6996 DOB: 5/3/1970 Crime Date: 4/30/2013 Status: Claim is currently under review. Decision expected within 7 days Claim#:041715-334 Initials: M.S. Last4SSN: 2957

More information

W 12 L-2: Laser photoelectric switches -- long-sighted, certainly, and no need for extra safety precautions

W 12 L-2: Laser photoelectric switches -- long-sighted, certainly, and no need for extra safety precautions Lichtschranken W L- Laser photoelectric Baureihe WL switches - Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W L-: Laser photoelectric switches

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output. Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling

More information

Long-distance capacitive proximity sensor. Ordering Information EB-74. Sensors. Accessories (Order Separately) Mounting Brackets. Unshielded.

Long-distance capacitive proximity sensor. Ordering Information EB-74. Sensors. Accessories (Order Separately) Mounting Brackets. Unshielded. Long-distance capacitive proximity sensor Capacitive Proximity Sensor with Adjustable Sensitivity Detects both metallic and non-metallic objects (glass, lumber, water, oil, plastic, etc.) without direct

More information

Pressure Sensors. for neutral and slightly aggressive liquids and gases

Pressure Sensors. for neutral and slightly aggressive liquids and gases 1909P01 Pressure Sensors for neutral and slightly aggressive liquids and gases QBE2003-P QBE2103-P High-precision measuring Measuring range 0 to 60 bar relative Supply voltage AC 24 V / DC 12...33 V or

More information

Wind Sensor type WSS REC

Wind Sensor type WSS REC USER s MANUAL/INSTALLATION NOTE Wind Sensor type WSS REC Mounting Connection Technical specifications References Document no.: 4189350037B Table of contents 1. INTRODUCTION... 3 UNPACKING... 4 LEGAL INFORMATION

More information

Differential pressure sensors

Differential pressure sensors 1 923 1923P01 Differential pressure sensors for neutral or slightly aggressive gases and liquids QBE61.3-DP.. Operating voltage AC 24 V or DC 18...33 V Output signal DC 0...10 V Connecting male thread

More information

E2K-C. Long-distance Capacitive Proximity Sensor. Ordering Information. Sensors. Accessories (Order Separately) Mounting Brackets.

E2K-C. Long-distance Capacitive Proximity Sensor. Ordering Information. Sensors. Accessories (Order Separately) Mounting Brackets. Long-distance Capacitive Proximity Sensor Capacitive Proximity Sensor with Adjustable Sensitivity Detects both metallic and non-metallic objects (glass, lumber, water, oil, plastic, etc.) without direct

More information

W 260: Standard photoelectric switch series for a broad range of applications

W 260: Standard photoelectric switch series for a broad range of applications W 0 Photoelectric switches Photoelectric proximity switches, BGS Photoelectric proximity switches, energetic Photoelectric reflex switches W 0: Standard photoelectric switch series for a broad range of

More information

Analog output module. 4 outputs, voltage and current

Analog output module. 4 outputs, voltage and current 2 Bosch Rexroth AG Electric Drives and Controls Documentation 4 outputs: M12, 0 to 10 V, ±10 V; 0 to 20 ma, ±20 ma, 4 to 20 ma Technical data S67-AO4-U/I-M12 Local bus interface Designation System bus

More information

Linear encoders without bearings incremental System for linear motion feedback

Linear encoders without bearings incremental System for linear motion feedback Features Robust magnetic sensing method Output signals A 90 B with index signal Output circuits: HTL/push-pull and TTL/RS422 Resolution up to 5 µm (4-times evaluation) Non-contact, wear-free sensing system

More information

Data Sheet SIMATIC S7-200 CPU 226 DC/DC/DC and CPU 226 AC/DC/Relay

Data Sheet SIMATIC S7-200 CPU 226 DC/DC/DC and CPU 226 AC/DC/Relay SIMATIC S7-200 and Table 1 Specifications for and Physical Size Dimensions (W x H x D) Weight Power loss (dissipation) CPU Features On-board digital inputs On-board digital outputs High speed counters

More information

Exposed Linear Encoder Compact Model Range

Exposed Linear Encoder Compact Model Range we set the standards LIK 41 Exposed Linear Encoder Compact Model Range Exposed Linear Encoder; compact model range Features Extremly small dimensions of scanning head for crowded installation conditions

More information

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur. egment Protector for Cabinet nstallation Features Assembly 4... 12 outputs Ex ic (FCO or Entity) or non-incendive (Div 2) Advanced fault isolation at the spur egment Protector in Zone 2/Div. 2 nstruments

More information

Measurement range. Protection class. Resolution 0.03 % ( ); 0.1 % ( ) Repeatability ±0.03 % ( ); ±0.1 % (15...

Measurement range. Protection class. Resolution 0.03 % ( ); 0.1 % ( ) Repeatability ±0.03 % ( ); ±0.1 % (15... Magnetic Angle Sensor with Analog Output Magnetic angle 0-360 Measurement range 0-360 Protection class IP60 Analog output Non-contact with external position magnet Wear free Compact, low profile housing

More information

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049

More information

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male

More information

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Magnetic field sensor magnet-inductive proximity sensor BIM-M12E-Y1X-H1141

Magnetic field sensor magnet-inductive proximity sensor BIM-M12E-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M12 x 1 Chrome-plated brass Rated operating distance 90 mm with DMR31-15-5 magnet DC 2-wire, nom.

More information

Conveyors Electronic fences Forming operations Robot Cells Presses Workstations Washdown applications (use IP 67 tube accessory)

Conveyors Electronic fences Forming operations Robot Cells Presses Workstations Washdown applications (use IP 67 tube accessory) Point of Operation Control (POC) Light Curtains Features/Benefits Point of Operation Control light curtains are placed close to the hazard, at the point of operation where personnel may frequently interact

More information

Monitor for Measurement of Speed and Detection of Direction Series D224.xxS2

Monitor for Measurement of Speed and Detection of Direction Series D224.xxS2 D Monitor for Measurement of Speed and Detection of Series D.xxS KEY FEATURES Speed and Monitor with sensor monitoring and self-test function Frequency range 0 Hz 00 khz Analog Output 0/ 0 ma Bright red

More information

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Analog value representation

More information

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute

More information

Barcode positioning systems BPS 8, BPS 34/37 Innovations that truly move you forwards.

Barcode positioning systems BPS 8, BPS 34/37 Innovations that truly move you forwards. Barcode positioning systems BPS 8, BPS 34/37 Innovations that truly move you forwards. PRODUCT INFORMATION Flexible, tolerant and millimetre precision. The Leuze electronic barcode positioning system.

More information

W 27-2: The photoelectric switch series with expanded possibilities

W 27-2: The photoelectric switch series with expanded possibilities W - Photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W -: The photoelectric switch series with expanded possibilities metres

More information

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up

More information

The consensus of the Pharmacy Practice Model Summit Am J Health-Syst Pharm. 2011; 68:1148-52 This list of the Pharmacy Practice

The consensus of the Pharmacy Practice Model Summit Am J Health-Syst Pharm. 2011; 68:1148-52 This list of the Pharmacy Practice The consensus of the summit The consensus of the Pharmacy Practice Model Summit Am J Health-Syst Pharm. 2011; 68:1148-52 This list of the Pharmacy Practice Model Summit s 147 points of consensus about

More information

6ES7 313-6BE01-0AB0 6ES7 313-5BE01-0AB0

6ES7 313-6BE01-0AB0 6ES7 313-5BE01-0AB0 4 SIMATIC S7-300 Central processing units CPU 312C to CPU 317F-2 DP CPU 317F-2 DP The failsafe CPU with a large program memory and quantity framework for demanding applications For configuration of a failsaf

More information

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications Bar Code Reader Series BCL 20 A flexible reader for a variety of applications PRODUCT INFORMATION The benchmark for flexibility. Laser scanners of the BCL 20 series as variable as your requirements demand.

More information

Conductive Level Switch FK 2 Technical Data:

Conductive Level Switch FK 2 Technical Data: Level switch for conductive liquids Optional electrode length adjustment Hygienic installation in accordance with EHEDG Wetted parts compatible with FDA requirements Potted electronic Not influenced by

More information

Watt-hour Meter Interface Module

Watt-hour Meter Interface Module Watt-hour Meter Interface Module MIM-B16* PIM (Pulse Input Module) Watt-hour Meter Interface Module can be exclusively used for DMS 2 power distribution, displaying power consumption for each watt-hour

More information

W 36: Mastering complex tasks reliably

W 36: Mastering complex tasks reliably Lichtschranken W Photoelectric Baureihe switches WL - Photoelectric proximity switches, BGS Photoelectric reflex switches W : astering complex tasks reliably Through-beam photoelectric switches for temperatures

More information

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range) Description The sensors provide excellent results even with difficult-to-detect objects, e.g. small or thin parts, wires or bright metals. A variety of types cover a wide range of individual requirements

More information

S 130: Ultra-miniature photoelectric switches for new sensing opportunities

S 130: Ultra-miniature photoelectric switches for new sensing opportunities Barrières S 0 Photoelectric S 0 switches Photoelectric proximity switches, energetic Contrast scanners Through-beam photoelectric switches S 0: Ultra-miniature photoelectric switches for new sensing opportunities

More information

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.

More information

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service

More information

Cylinder Series PNC, to ISO 6431 and VDMA

Cylinder Series PNC, to ISO 6431 and VDMA Cylinder Series PNC, ISO 6431 and VDMA 24 562 Page 1 of11 Cylinder Series PNC, to ISO 6431 and VDMA 24 562 How to Order PNC ---------------- Ø ---------------------------- Stroke --------- S PNC: basic

More information

Electronic Pressure Switch EDS 3000

Electronic Pressure Switch EDS 3000 For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or

More information

DS 600. A contact free flux gate based current measurement sensor 600A rms

DS 600. A contact free flux gate based current measurement sensor 600A rms DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum

More information

Option field bus: without bus with profibus DP. Design-Index (Subject to change)

Option field bus: without bus with profibus DP. Design-Index (Subject to change) Amplifier / controller cards ED1 Digital amplifier / controller card ED1 for 1 or 2 proportional solenoids 4 analogue inputs, of which 2 for differential inputs 8 digital inputs Card setting via PC, multi-function

More information

Timing relay module DC 24 110 V, programmable

Timing relay module DC 24 110 V, programmable Subject to technical modification 815000.00 Identification Type ZR6-5000.00 Product version Datasheet version 00 Use/Area of application Description The programmable timing relay consists of 2 changeover

More information

Color Mark Sensor with Red or Green LED E3S-VS

Color Mark Sensor with Red or Green LED E3S-VS Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

PROFIBUS DP ACTIVE TERMINATOR

PROFIBUS DP ACTIVE TERMINATOR USER S MANUAL PROFIBUS DP ACTIVE TERMINATOR AT303 A T 3 0 3 M E smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is available on our

More information

Differential Pressure Sensor

Differential Pressure Sensor 1 921 1921P01 Differential Pressure Sensor for neutral and mildly corrosive liquids and gases QBE64-DP4 Differential pressure sensor, suitable for gases or liquids, for the measurement of positive or negative

More information

TECHNICAL DATASHEET Incremental Encoder RI 58-H

TECHNICAL DATASHEET Incremental Encoder RI 58-H Through hollow shaft High accuracy by means of integrated flexible coupling Safe shaft mounting Applications: textile machines, motors, drives, copiers NUMBER OF PULSES 1 / 2 / 3 / 4 / 5 / 10 / 15 / 20

More information

Application. 13 green/(brown) 14 yellow/(blue) 23 brown/(black) 24 white/(white) 13 (brown) 14 (blue) 23 (black) 24 (white) 32 (pink +U B )

Application. 13 green/(brown) 14 yellow/(blue) 23 brown/(black) 24 white/(white) 13 (brown) 14 (blue) 23 (black) 24 (white) 32 (pink +U B ) afety Technique Accessories for afety Applications Magnetic witch coded NE 5021 093 Function Diagram Usable for safety application by using a correctly installed and, security module (e. g. BG 5925/920

More information

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M. Inductive sensor, IE series, IE08, DC-wire, Standard series, Flush Inductive sensor Sensing range.5 mm Short-circuit protection (pulsed) Dimensional drawing 8x Robust brass housing, nickelplated with fine

More information

CBT-120 LEDs. CBT-120 Product Datasheet. Features: Table of Contents. Applications

CBT-120 LEDs. CBT-120 Product Datasheet. Features: Table of Contents. Applications CBT-2 LEDs Features: Table of Contents Technology Overview.... 2 Test Specifications... 2 Bin Codes.... 3 Product Shipping & Labeling Information.... 4 Optical & Electrical Characteristics.... 5 Flux &

More information

DATING YOUR GUILD 1952-1960

DATING YOUR GUILD 1952-1960 DATING YOUR GUILD 1952-1960 YEAR APPROXIMATE LAST SERIAL NUMBER PRODUCED 1953 1000-1500 1954 1500-2200 1955 2200-3000 1956 3000-4000 1957 4000-5700 1958 5700-8300 1959 12035 1960-1969 This chart displays

More information

Differential Pressure Sensors

Differential Pressure Sensors 1 920 1920P01 Differential Pressure Sensors for neutral and mildly corrosive liquids and gases QBE63-DP... Differential pressure sensor, suitable for gases and liquids, for the measurement of positive

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 1 semiconductor output Connection

More information

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall

More information

Universal Voltage Terminal Photoelectric E3JM

Universal Voltage Terminal Photoelectric E3JM Universal Voltage Terminal Photoelectric Universal AC/DC Photoelectric Sensor with Built-in Timer Easy-to-wire terminal block Built-in timer offers selectable ON-delay, OFF-delay and one-shot Relay or

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

Photoelectric Sensor

Photoelectric Sensor Photoelectric Sensor Photoelectric Sensor with Built-in Supply and Wiring Terminal Block for Easy Maintenance and Reliable Operation Available for both AC and DC, with self-contained timer function Easy-to-wire

More information

LCM Design Engineering SPECIFICATION FOR LCD MODULE TYPE ITEM NO.: MDLS16265-04 MDLS16265-LV-G-LED04G (BB) (DOC. REVISION 1.0)

LCM Design Engineering SPECIFICATION FOR LCD MODULE TYPE ITEM NO.: MDLS16265-04 MDLS16265-LV-G-LED04G (BB) (DOC. REVISION 1.0) VARITRONIX LIMITED LCM Design Engineering SPECIFICATION FOR LCD MODULE TYPE ITEM NO.: MDLS16265-04 MDLS16265-LV-G-LED04G (BB) (DOC. REVISION 1.0) DEPARTMENT NAME SIGNATURE EFFECTIVE DATE PREPARED BY PHILIP

More information

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series Programmable Terminal NPSeries Easy Setup with the Low-cost, Compact NP Series Simpler and More Versatile.OMRON s Compact NP Series Connect! Easier connection to OMRON PLCs and Temperature Controllers,

More information

is then retained absolutely without interruption.

is then retained absolutely without interruption. Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

MINI MCR-SL-UI-UI-NC. Extract from the online catalog. Order No.:

MINI MCR-SL-UI-UI-NC. Extract from the online catalog. Order No.: Extract from the online catalog MINI MCR-SL-UI-UI-NC Order No.: 2864150 MCR 3-way isolating amplifier for electrical isolation of analog signals, input/output configurable via DIP switch, with screw connection,

More information

My first Hirschmann: The SPIDER family of switches.

My first Hirschmann: The SPIDER family of switches. My first Hirschmann: The SPIDER family of switches. Large selection of entry level switches Compact design Simple rail installation Industry standard 24 V supply voltage Plug & Play gets you up and running

More information

Final Review Chapter 5

Final Review Chapter 5 Name: Class: Date: Final Review Chapter 5 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. Find the length of the midsegment. The diagram is not to scale.

More information