At Ancon, it s all part of the service
|
|
- Oswin Craig
- 7 years ago
- Views:
Transcription
1 1 At Ancon, it s all part of the service
2 CE Marking to the CPR: What does it all mean?
3 What do we mean by CE Marking? CE marking is a method of identifying those products that comply with a harmonised European Standard or have a European Technical Approval. With effect from 1st July 2013, under the new Construction Products Regulation (CPR), virtually all construction products must carry the CE mark before they can legally be sold in Europe. There are various exceptions. Many new or innovative products, for instance, fall outside the scope of current European Standards/Technical Approvals and therefore cannot be CE marked. Where it is applied, CE marking makes it easy for specifiers, distributors and end users across Europe to see immediately that a product has a standard technical specification and, as the information and layout is standardised too, it helps simplify comparisons between products manufactured in different countries, encouraging trade. The CE mark is applied either directly to a product, its packaging or to its accompanying documentation. CE marking, however, does not replace local Building Regulations. Users in the UK still need to ensure that a product complies with any local market requirements. For example, in addition to declaring performance in tension and compression to the European Standard EN 845 Part 1, cavity wall ties in England and Wales should also meet the acoustic requirements of Approved Document E: Resistance to the passage of sound. Did you know? CE is an abbreviation of the French, Conformité Européenne, meaning European Conformity. 3
4 How does CE Marking work? CE marking is not new it has been compulsory for a wide range of everyday products for many years for instance, toys, machinery and electrical items. Under the new Construction Products Regulation, it is mandatory to apply the mark to a construction product covered by a harmonised European Standard or when it conforms to a European Technical Assessment that has been issued for it. To qualify for a CE mark, manufacturers must undertake several tasks. These are specific to each product type and are given in the Standard. Tasks include: Testing of each product type Ensuring the necessary factory production controls are in place to guarantee consistency Publishing a signed Declaration of Performance (DoP) for each product Issuing the CE mark with the product, accompanied by any essential additional information In some cases, the tasks must be undertaken by an approved external body, rather than the manufacturer. The Declaration of Performance, also referred to as an EC Declaration of Conformity by many current European Standards, must be readily available and translated into the language of the country in which the product is supplied. A hard copy must be available on request. Once the DoP has been completed, and the CE mark applied, the manufacturer has a legal responsibility to ensure the product continues to conform to the Standard. Failure to CE mark a product where required, or to ensure ongoing conformity, leaves a manufacturer open to legal action. Products concerned can be removed from sale by enforcement agencies e.g. Trading Standards in the UK. 4
5 Ancon products that carry the CE mark Ancon Product(s) Relevant European Key Requirements Standard/Approval of CE Marking Masonry supports Windposts Tension systems Compression systems Steel balcony connectors Other fabricated components EN Part 1. Execution of steel structures and aluminium structures. Requirements for conformity assessment of structural components Legal Requirement: 1 July 2014 Designs to EN 1993 (Eurocode 3) Inspection of factory production controls by an approved body including welding certification* Cavity wall ties Frame cramps Movement ties Head restraints Channel ties Stone fixings EN 845. Part 1. Specification for ancillary components for masonry: Ties, tension straps, hangars and brackets Legal Requirement: 1 July 2013 Extensive independent product testing Lintels EN 845. Part 2. Lintels Legal Requirement: 1 July 2013 Extensive independent product testing Masonry reinforcements AMR, AMR-X and AMR-CJ EN 845. Part 3. Bed joint reinforcement of steel meshwork Legal Requirement: 1 July 2013 Extensive independent product testing *Ancon is certified to undertake welded fabrication work to Execution Class 2 to EN This covers the majority of building applications and is the default class when unspecified. For more information on Execution Classes, please visit or contact Ancon. 5
6 What Ancon has done to ensure CE Marking compliance As a leading manufacturer of steel construction products, with established sales throughout Europe, Ancon has been working with CE Marking legislation for many years. In fact, it has been mandatory in many of our key European markets for some time. To prepare for its adoption in the UK and Ireland, where we sell a slightly different portfolio of products, we successfully carried out extensive independent product testing, passed external audits of our manufacturing facilities, published the necessary collection of Declarations (DoP s) and have applied the CE mark to all affected Ancon products. Employees from across the business, in purchasing, production, engineering, marketing and sales, worked together to meet the CE marking deadline, and have ensured all necessary working practices, procedures and skills are in place to achieve and maintain compliance with all aspects of the Construction Products Regulations. Since 1st July 2013, all Ancon products have carried a CE mark where required. CE mark and additional essential information Issued on the product, packaging or with associated product delivery documentation 6
7 Declaration of Performance Declaration Number: A EN ANCON hereby declares that the product range identified as, ST1 225mm conforms to the provisions of, ZA Annex, EN 845-1: A1: 2008 as a, Symmetrical Wall Tie covered in clause 1 of the standard Intended Use: Supporting documentation Declaration of Performance (DoP) available for each product. Type 1 wall tie for connecting two leaves of a cavity wall. Suitable for mm cavities. Declaration of Performance Notified Body: Declaration Number: A EN ANCON hereby declares that the product identified as CERAM Research Limited Queens Road, Penkhull STOKE-ON-TRENT ST4 7LQ United Kingdom Tel: +44 (0) AMR/S/D5.0/W60 Notified Body Number: 1289 conforms to the provisions of Annex ZA, BS EN 845-3:2003+A1:2008, as Bed Joint Reinforcement defined in of the Standard This product conforms to System 3 - Assessment and Verification of Constancy of Performance. All necessary testing was conducted at the above notified body. For structural uses in walls and partitions Intended Use: Essential Characteristics CERAM Research Limited Compressive Load Capacity: 4600N (M2 (iv) Mortar), 5640N (M12 (i) Mortar) Queens Road, Penkhull Tensile Load Capacity: ST4 7LQ 4060N (M2 (iv) Mortar), 5490N (M12 (i) Mortar) STOKE-ON-TRENT Notified Body: United Kingdom Water Shedding Capability: Resistant Tel: +44 (0) Durability: Material/coating reference 3, Steel grade Notified Body Number: Dangerous 1289 Substances: None Conditions conforms to System 3 - Assessment and Verification of Constancy of Performance. All necessary testing was conducted at the above notified body. min. 62.5mm Embedment Depth: Manufactured by: This product Minimum Mortar Joint Width: Product Dimensions, Performance and Durability Recommended Spacing: Ancon Building Products Length: President Way President Park Width: Sheffield S4 7UR United Kingdom Authorised by: Profile Height: Tel: +44 (0) Fax: +44 (0) Wire Longitudinal info@ancon.co.uk Web: Cross Wire Size: Size: Tel: +44 (0) Fax: +44 (0) info@ancon.co.uk Web: ±0.4mm 7.35 ±0.1mm Characteristic Yield Strength of Longitudinal Wires: Ancon Building Products President Way President Park Sheffield S4 7UR United Kingdom 60 ±5mm 2.30 ±0.1mm Stuart Maxwell, Managing Director, on 16th May 2013 Pitch of Cross Wires: Manufactured by: 10mm Refer to Clause PD 6697: ±1.5% 450 ±3.0% 500N/mm2 Characteristic Yield Strength of Cross Wires: 500N/mm2 Bond Strength: 21150N Lap Length: 225mm (to include at least one cross wire) Shear Load Capacity of Welds: 2000N Ductility: Normal Durability - Material/Coating Reference: R3 (Stainless Steel) Dangerous Substances: None Authorised by: Stuart Maxwell, Managing Director, on 1st May 2013 Certification documents Factory production control certificates from an approved third party including welding certification. 7
8 Your CE Marking questions answered Q: I am a distributor, does CE Marking affect me? A: You need to be sure that all of the construction products you sell meet the requirements of the CPR and carry the CE mark where appropriate. You also need to ensure products are accompanied by the correct documentation and that relevant additional information is supplied when requested. Ancon distributors can be confident that all of our products meet the CPR requirements and are CE marked where appropriate. You can download any Declaration of Performance (DoP) and other relevant information from Q: I am a distributor, what about old stock which does not carry a CE mark? A: Only construction products manufactured after 1st July 2013 are affected. Stock supplied before this date is unaffected. Q: I am a contractor, CE Marking doesn t affect me, does it? A: You need to be satisfied that the products you use meet the requirements of the CPR, as well as meeting the performance criteria for the project involved. The project engineer s specification should take all this into account. You should also be aware that if you modify a CE marked product in any way that may affect the DoP, you effectively become the manufacturer. You must therefore carry out any necessary testing, draw up your own Declaration of Performance and ensure continuing compliance with the Regulation. All Ancon products are CE marked where required and we offer free technical support on product suitability. Our DoP s are available from Some Ancon products can be modified on site to our instructions, without affecting the validity of the CE mark e.g. AnconOptima masonry support. 8
9 Q: I am an engineer, do I need to make any changes to how I specify products? A: Product specifications should be amended to include CE marked items only, where the product is covered by a harmonised European Standard e.g. masonry support systems, windposts, wall ties and bed joint reinforcement. A list of harmonised standards is available from NANDO By specifying Ancon, engineers are guaranteed CE marked products, backed by Eurocode designs and third party assessed production controls where required. Ancon provides technical advice and specification assistance. Q: What about Ancon products that are not currently covered by a harmonised European standard (hen) or ETA can I still specify, sell or use them? A: Yes, this is completely acceptable. Some Ancon products are legitimately outside of CE marking requirements. Ancon uses independent test houses and holds a number of voluntary, third party approvals for its products (see page 10). Our test regimes and approvals have similar or sometimes even more stringent requirements than those of CE marking. We are continuing to monitor the position with regards to new European Standards, and will publish any changes at 9
10 Ancon products excluded from CE Marking legislation These products are outside the scope of CE marking. They have been independently tested and most carry a voluntary mark from a recognised third party to provide greater assurance of our product performance data and/or manufacturing controls. Punching Shear Reinforcement Shearfix Reinforcing Bar Couplers MBT/TT/Bartec Reinforcement Continuity Systems Eazistrip/KSN Balcony Connectors Isolan Shear Load Connectors DSD/HLD/Lockable Dowel Wall Starters Universal/Quickstart Tested at EMPA Tested at Tested at Wall Ties Teplo Cast-in Channels with Crimped Anchor Pairs Warm Roof Helical Fixings 10 Tested to BS 5080, Parts 1 & 2 Tested at
11
12 First published June 2013 Updated June 2016 Ancon Building Products President Way President Park Sheffield S4 7UR Tel: +44(0) Fax: +44(0)
Policy Briefing. Frequently Asked Questions on the Construction Products Regulation and CE marking. December 2012. Background
Frequently Asked Questions on the Construction Products Regulation and CE marking December 2012 Background The following list of frequently asked questions has been produced by an MPA Working Group and
More informationGuidance Note on the Construction Products Regulation
Guidance Note on the Construction Products Regulation Version 1 - April 2012 APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS FOR CONSTRUCTION Guidance Note on the Construction Products Regulation
More informationMandate M/116 MASONRY AND RELATED PRODUCTS
Mandate M/116 Page 1 sur 19 Mandate M/116 MANDATE TO CEN/CENELEC CONCERNING THE EXECUTION OF STANDARDISATION WORK FOR HARMONIZED STANDARDS ON CReatE MASONR AND RELATED PRODUCTS RELATED TO THE FOLLOWING
More informationConstruction Products Regulation
Construction Products Regulation (305/2011/EU) Engineers Ireland 27 th September 2013 Sarah Neary BE MBA CEng MIEI Senior Adviser Building Standards Environment, Community and Local Government What has
More informationWelded Fabric. The CARES Guide to Reinforcing Steels Part 5. Installation of welded fabric on a major contract. 1.0 Introduction
Welded Fabric 1.0 Introduction Welded fabric, often referred to as mesh, is a machine welded grid arrangement of reinforcing bars or wires. It is covered by British Standard BS4483. This was revised in
More informationTechnical Application Document. Hilti HIT-RE 500-SD
Technical Application Document Technical Evaluation Report 3/10-649 Injection system for rebar connections Hilti HIT-RE 500-SD Subject to European Technical Approval ATE-09/0295 Holder of approval: HILTI
More informationThe Danish Energy Agency will carry out inspections in October 2013. We will check the CE marking of the smoke alarms you sell or use.
Table of Contents Table of Contents... 1 The Danish Energy Agency will carry out inspections in September and October 2013... 2 What is CE marking of a construction product?... 3 Where can you find the
More informationStandards, Codes and Regulations
Standards, Codes and Regulations 1.0 Introduction The production of a European standard for reinforcing steels began in 1988. The key stumbling block to bringing what may be regarded as a normal European
More informationEuropean Technical Assessment ETA-10/0153 of 10/06/2015
ETA-Danmark A/S Göteborg Plads 1 DK-2150 Nordhavn Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet ww.etadanmark.dk Authorised and notified according to Article 29 of the Regulation (EU) No 305/2011 of
More informationYour essential guide to CE Marking
Your essential guide to CE Marking CE marking A guide for window and door fabricators This guide provides essential information that will help you with your preparations for CE marking. A flowchart is
More informationStandards, Codes and Regulations
Standards, Codes and Regulations 1.0 Introduction The production of a European standard for reinforcing steels began in 1988. The key stumbling block to bringing this to fruition was the inability to agree
More informationEurocode 2: Design of concrete structures
Eurocode 2: Design of concrete structures Owen Brooker, The Concrete Centre Introduction The transition to using the Eurocodes is a daunting prospect for engineers, but this needn t be the case. Industry
More informationCE mark now! Mandatory CE marking of construction products 1 July 2013
CE mark now! Mandatory CE marking of construction products 1 July 2013 Mandatory CE marking of construction products 1 July 2013 From 1 July 2013, construction products covered by a harmonised standard
More informationConstruction Products Regulation Are you ready?
Construction Products Regulation Are you ready? Sarah Neary BE MBA CEng MIEI Senior Adviser Building Standards Environment, Community and Local Government What s going to change and for who? From July
More informationSteel procurement in major projects: Guidance on the application of social issues. Purpose
Steel procurement in major projects: Guidance on the application of social issues Purpose 1. This is a practical guide on how to incorporate social issues in major projects with a significant steel component.
More informationIntroduction. Eurocodes. Specification. Cost
Introduction Eurocodes Specification Cost Structural Eurocodes BS EN 1990 (EC0): BS EN 1991 (EC1): Basis of structural design Actions on Structures BS EN 1992 (EC2): BS EN 1993 (EC3): BS EN 1994 (EC4):
More informationUnderstanding BS EN 771-3: Aggregate concrete masonry units
60 Charles Street, Leicester LE1 1FB Tel: 0116 253 6161 Fax: 0116 251 4568 Email: enquiries@cba-blocks.org.uk Website: www.cba-blocks.org.uk February 2006 Understanding BS EN 771-3: Aggregate concrete
More informationAssessment Report Construction Product Regulation* * CPR - REGULATION (EU) No 305/2011
1. plan 1) Goal: Assessment and verification of the constancy of performance of the products as described by the manufacturer in his Declaration of Performance through: initial inspection of the manufacturing
More informationGeorgios Katsarakis Europäische Kommission
Georgios Katsarakis Europäische Kommission Implementing the Construction Products Regulation (EU) 305/2011 G. Katsarakis European Commission, DG Enterprise and Industry Unit B-1: Sustainable Industrial
More informationGuiding Principles for the contents of Particular Materials Appraisals (Version approved at the WGP on 21 November 2006)
PE- 03-28 - rev 5 21 November 2006 Page 1 of 5 Guiding Principles for the contents of Particular Materials Appraisals (Version approved at the WGP on 21 November 2006) Introduction A Particular Material
More informationDOCUMENT CAESAS/1: SCHEME DESCRIPTION AND BENEFITS
CONFORMITY ASSESSMENT FOR THE EXECUTION OF STEEL & ALUMINIUM STRUCTURES DOCUMENT CAESAS/1: SCHEME DESCRIPTION AND BENEFITS 2nd Edition July 2012 Issued under the authority of the Governing Board for Certification
More informationQuality Regulations for Profiles
Quality Regulations for Profiles September 2010 Quality Regulations for Profiles Page 2/42 Contents Preface... 4 1. Terms and Definitions... 5 1.1 Third parties... 5 1.2 Independent laboratories... 5 1.3
More informationConnection Solutions
Connection Solutions DESIGN BUILD SYSTEM Connection Solutions for Cold formed Steel Construction Complies with; AS/NZS 4600:2005 AISI S100:2007 AS/NZ 1397 ASTM A653 DESIGN & BUILD SYSTEM FRAMECAD Construction
More informationScope of EN 1090-1 Clarification Document
Scope of EN 1090-1 Clarification Document This document has been submitted to the European Commission as the UK view on the scope of EN 1090-1. After discussions, including with the European Technical
More informationSTEEL CONSTRUCTION CE Marking
STEEL CONSTRUCTION CE Marking 2 CE MARKING Foreword The construction industry is facing one of the most significant changes for a decade as CE Marking of construction products becomes mandatory in all
More informationCavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.
CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,
More informationIRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION
IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION Bill Robinson BSc. C. Eng. M. I. Struct. E. Timber Design Services 1 IS440 Timber frame
More informationEuropean Technical Approval ETA-12/0500
ETA-Danmark A/S Kollegievej 6 DK-2920 Charlottenlund Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet www.etadanmark.dk Authorised and notified according to Article 10 of the Council Directive 89/106/EEC
More informationINSTRUCTIONS FOR USE
2/2013 ANCHOR BOLTS INSTRUCTIONS FOR USE - Threaded rebars ATP, AHP, AJP - Threaded high strength steel bolts ALP-L, ALP-P, AMP ATP AHP ALP-L ALP-P AMP Eurocode design according to EN1993-1-8 (2005) &
More informationFire safety in buildings and implementation of European fire test standards
Fire safety in buildings and implementation of European fire test standards Dr Debbie Smith OBE Chair of CEN TC127 Fire Safety BRE Global Ltd, UK 18 th June 2014 Part of the BRE Trust Construction Products
More informationThe Work at Height Safety Association. Guidance on inspecting eyebolts used for personal fall protection purposes
The Work at Height Safety Association Technical Guidance Note 6 Guidance on inspecting eyebolts used for personal fall protection purposes A series of informative notes for all industries involved with
More informationMaterials and workmanship
The Materials and workmanship APPROVED DOCUMENT Regulation 7 2013 edition for use in England* 7 Main changes in the 2013 edition This approved document supports regulation 7: Materials and workmanship.
More informationFLOORS REINFORCEMENT Shear Stud Connector for steel- concrete composite structures cold applied by pins
www.tecnaria.com FLOORS REINFORCEMENT Shear Stud Connector for steel concrete composite structures cold applied by pins HIGHPERFORMANCE FLOORS COMPOSITE STEEL AND CONCRETE STRUCTURES: STATIC AND ECONOMIC
More informationEXTENSION OF PERIODIC INSPECTION INTERVAL FOR LPG CYLINDERS
EXTENSION OF PERIODIC INSPECTION INTERVAL FOR LPG CYLINDERS VCA guidance for gaining authorisation in Great Britain Page 1 of 7 EXTENSION OF PERIODIC INSPECTION INTERVAL FOR LPG CYLINDERS VCA guidance
More informationPRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta
PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE By H P Gupta & D K Gupta DIFFERENT TYPES OF DAMAGES 1.Minor cracks 0.5 to 5 mm wide in load or non-load bearing walls 2.Major
More informationEuropean Organisation for Technical Approvals
Warrington Certification Limited, Holmesfield Road, Warrington, WA1 2DS Tel. +44 (0) 1925-646777 Fax +44 (0) 1925-646667 Member of EOTA Authorised and notified according to Article 10 of the Council Directive
More informationDetailing of Reinforcment in Concrete Structures
Chapter 8 Detailing of Reinforcment in Concrete Structures 8.1 Scope Provisions of Sec. 8.1 and 8.2 of Chapter 8 shall apply for detailing of reinforcement in reinforced concrete members, in general. For
More informationDesign and Construction of Cantilevered Reinforced Concrete Structures
Buildings Department Practice Note for Authorized Persons, Registered Structural Engineers and Registered Geotechnical Engineers APP-68 Design and Construction of Cantilevered Reinforced Concrete Structures
More informationThe Danish Enterprise and Construction Authority to inspect CE marking of windows and pedestrian doors
23. december 2010 The Danish Enterprise and Construction Authority to inspect CE marking of windows and pedestrian doors The Danish Enterprise and Construction Authority s market surveillance of construction
More informationDubai Municipality Standard DMS 1: Part 5: 2004
Specification for precast concrete blocks Part 5: Normal-weight concrete-polystyrene sandwich masonry blocks Issue Date Revision Revision Description Prepared by Approved by Authorized by 19/12/2004 Issue
More informationCertificate of Conformity of the Factory Production Control
Certificate of Conformity of the Factory Production Control 0836 CPR 14/F097 In compliance with the Regulation 305/2011/EU of the European Parliament and of the Council of 9 March 2011 (the Construction
More informationNATIONAL ALTERATIONS OF THE OVERSEEING ORGANISATIONS OF SCOTLAND, WALES AND NORTHERN IRELAND SERIES NG 100 PRELIMINARIES. Amendment May 2014 1
MANUAL OF CONTRACT DOCUMENTS FOR HIGHWAY WORKS VOLUME 2 NOTES FOR GUIDANCE ON THE SPECIFICATION FOR HIGHWAY WORKS SERIES NG 100 PRELIMINARIES Contents Clause Title Page NG 101 (05/14) Temporary Accommodation
More informationModule 7. CE marking of Vehicle Restraint Systems EN 1317 5. Göran Fredriksson, SSBA
Module 7. CE marking of Vehicle Restraint Systems EN 1317 5 Göran Fredriksson, SSBA The Construction Products Regulation (CPR) is the basis The Construction Products Regulation (CPR) lays down harmonised
More informationEuropean Technical Approval ETA 13/0526
European Technical Approval ETA 13/0526 Trade Name Holder of the approval Website Generic type and use of construction product DOLCEA i3 PCIM S.A. Rue du Péquet 54 5590 Achene (Ciney) Belgium www.isoproc.eu
More informationPartitioning & Ceiling Product Information
Partitioning & Ceiling Product Information tel + 44 (0) 1384 412448 fax + 44 (0) 1384 4494 email enquiries@drywallsteelsections.co.uk web www.drywallsteelsections.co.uk tel + 44 (0) 1384 412448 fax + 44
More informationEuropean Technical Approval ETA-10/0153
ETA-Danmark A/S Kollegievej 6 DK-2920 Charlottenlund Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet www.etadanmark.dk Authorised and notified according to Article 10 of the Council Directive 89/106/EEC
More informationMETHOD OF STATEMENT FOR STATIC LOADING TEST
Compression Test, METHOD OF STATEMENT FOR STATIC LOADING TEST Tension Test and Lateral Test According to the American Standards ASTM D1143 07, ASTM D3689 07, ASTM D3966 07 and Euro Codes EC7 Table of Contents
More informationRegulation (EU) No 305/2011 (CPR) and its mechanisms and potential consequences on environmental and sustainability tools in the construction sector
Regulation (EU) No 305/2011 (CPR) and its mechanisms and potential consequences on environmental and sustainability tools in the construction sector 57th LCA Discussion Forum 2 December 2014 Andreas J.
More informationEuropeiskt Tekniskt Godkännande European Technical Approval
SITAC Box 553 SE 371 23 Karlskrona SWEDEN MEMBER OF EOTA Tfn.: +46-(0)10-516 63 00 Fax: +46-(0)455-206 88 E-mail: info@sitac.se Europeiskt Tekniskt Godkännande European Technical Approval Handelsnamn Trade
More informationDesign Manual to BS8110
Design Manual to BS8110 February 2010 195 195 195 280 280 195 195 195 195 195 195 280 280 195 195 195 The specialist team at LinkStudPSR Limited have created this comprehensive Design Manual, to assist
More informationGuide to Gate Safety Legislation & the Machinery Directive. In Association with:
Guide to Gate Safety Legislation & the Machinery Directive In Association with: Tel: 0191 267 4922 info@primeautomation.co.uk Tel: 0191 267 4922 Email: info@primeautomation.co.uki Guide to Gate Safety
More informationEuropean Technical Assessment ETA-15/0028 of 23/02/2015
ETA-Danmark A/S Göteborg Plads 1 DK-2150 Nordhavn Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet ww.etadanmark.dk Authorised and notified according to Article 29 of the Regulation (EU) No 305/2011 of
More informationDECLARATION OF PERFORMANCE
Flooring Declaration of Performance Edition 01.07.2013 Identification no. Version no. 01 EN 1504-2: 2004 08 0921 EN 13813: 2002 DECLARATION OF PERFORMANCE Declaration of performance 1. Product Type Unique
More informationNEW AUSTRALIAN STANDARDS FOR MASONRY IN SMALL STRUCTURES S.J. LAWRENCE
NEW AUSTRALIAN STANDARDS FOR MASONRY IN SMALL STRUCTURES S.J. LAWRENCE Conjoint Professor Centre for Infrastructure Performance and Reliability The University of Newcastle Callaghan, NSW, Australia A.W.
More informationEurocode 4: Design of composite steel and concrete structures
Eurocode 4: Design of composite steel and concrete structures Dr Stephen Hicks, Manager Structural Systems, Heavy Engineering Research Association, New Zealand Introduction BS EN 1994 (Eurocode 4) is the
More informationRockwool Cladding Roll
Rockwool Cladding Roll High performance industrial insulation has been specifically developed for use in lightweight cladding applications to commercial or industrial framed buildings. Cladding Roll U/F
More informationEuropean Technical Approval ETA-06/0259
European Technical Approval ETA-06/0259 - Original version in German language Handelsbezeichnung Trade name Zulassungsinhaber Holder of approval Zulassungsgegenstand und Verwendungszweck Generic type and
More informationDraft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI 318-14
Draft Table of Contents Building Code Requirements for Structural Concrete and Commentary ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318 14) Chapter 1 General 1.1 Scope of ACI 318
More informationSERIES NG 1800 STRUCTURAL STEELWORK
MANUAL OF CONTRACT DOCUMENTS FOR HIGHWAY WORKS VOLUME 2 NOTES FOR GUIDANCE ON THE SPECIFICATION FOR HIGHWAY WORKS SERIES NG 1800 STRUCTURAL STEELWORK Contents Clause Title Page NG 1800 (08/14) General
More informationBuilt-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5
Cl Sfb (27-9) Rn7 M2 December 2004 Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5 Fesco, Fesco S, Retrofit, Retrofit S, Fesco Fillet, PF,
More informationRockwool Flexi Insulation Application Guide
Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed
More informationGuide to Safety Edge Systems
Guide to Safety Edge Systems Tel: 0845 054 5070 asosafety@egduk.com Guide to Safety Edges All new automatic gate & door systems installed in the UK should comply to BS-EN13241-1 & EN-138491-1 harmonised
More informationSteel construction. Solutions for the renewable energy and offshore sectors. published by energyengineering magazine
Steel construction Solutions for the renewable energy and offshore sectors published by energyengineering magazine SCI-Energy-Supplement.indd 1 25/10/2010 13:00:22 Introduction SCI is a world leader in
More informationEuropean technical approval
Authorised and notified according to Article 10 of the Council Directive 89/ 106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of Member States relating
More informationLinear Motion & Assembly Technologies - Guarding System
Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Linear Motion & Assembly Technologies - Guarding System EcoSafe Guarding System from Rexroth Guarding
More informationEuropean technical approval
Authorised and notified according to Article 10 of the Council Directive 89/ 106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of Member States relating
More informationIntegrated Manhole Ladder System
Application: This innovative product has been designed to provide safe access and egress to precast concrete manholes and inspection chambers. It can also be used within any other underground concrete
More informationTechnical Notes 3B - Brick Masonry Section Properties May 1993
Technical Notes 3B - Brick Masonry Section Properties May 1993 Abstract: This Technical Notes is a design aid for the Building Code Requirements for Masonry Structures (ACI 530/ASCE 5/TMS 402-92) and Specifications
More informationTHE DEVELOPMENT OF DESIGN METHODS FOR REINFORCED AND UNREINFORCED MASONRY BASEMENT WALLS J.J. ROBERTS
THE DEVELOPMENT OF DESIGN METHODS FOR REINFORCED AND UNREINFORCED MASONRY BASEMENT WALLS J.J. ROBERTS Technical Innovation Consultancy Emeritus Professor of Civil Engineering Kingston University, London.
More information1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona
for Earthen Material and Straw Bale Structures SECTION 70 - GENERAL "APPENDIX CHAPTER 7 - EARTHEN MATERIAL STRUCTURES 70. Purpose. The purpose of this chapter is to establish minimum standards of safety
More informationThe Kingspan Insulation Price List 1 st January 2013
Insulation The Kingspan Insulation Price List 1 st January 2013 FOR BUILDING FABRIC INSULATION, CAVITY CLOSERS AND MEMBRANES Visit our website: www.kingspaninsulation.co.uk Low Energy - Low Carbon Buildings
More informationThe National standardization and Current status of Eurocodes in Turkey
ADOPTION OF THE EUROCODES IN THE BALKAN REGION 5-6 December 2013, Milan & Ispra, Italy The National standardization and Current status of Eurocodes in Turkey Atila ERENLER (Deputy DG-MoEU) Prof. Dr. Ahmet
More informationbest practice guide BS EN 1154 Controlled Door Closing Devices to in association with
CI/SfB (32) Xt7 June 2009 best practice guide Controlled Door Closing Devices to BS EN 1154 in association with Permission to reproduce extracts from BS EN 1154: 1997 + A1: 2003 is granted by BSI. DHF
More informationPRODUCT SHEET 1 MIDLAND LEAD MANUFACTURERS LTD S CAST LEAD SHEET
CI/SfB (49) Mh8 Midland Lead Manufacturers Ltd Kiln Way Woodville Swadlincote Derbyshire DE11 8ED Tel: 01283 224555 Fax: 01283 550284 e-mail: sales@midlandlead.co.uk website: www.midlandlead.co.uk Agrément
More informationDOCUMENT CS/1: SCHEME DESCRIPTION AND BENEFITS
WELDING FABRICATOR CERTIFICATION SCHEME DOCUMENT CS/1: SCHEME DESCRIPTION AND BENEFITS 6 th Edition July 2012 Issued under the authority of the Governing Board for Certification All correspondence should
More informationDesigning with Gabions
Designing with Gabions Volume 2 A Reference Guide for Architectural Gabion Cladding and Free Standing Walls Registered Office: Unit 5, The Cobden Centre, Folly Brook Road, Emerald Park, Emersons Green,
More informationHorizontal Anchorage Device
Horizontal Anchorage Device The Law requires protection against falling from height Building owners and managers must provide safe systems of work! Why fall protection? Gravity kills! Falls from height
More informationElectrical Contractors Association
Electrical Contractors Association Presents BS 7671 2008: Amendment No 1 BS 7671: 2008 Amendment No 1, 2011 IEE Wiring Regulations Now called IET Wiring Regulations History 1882 first edition of the Wiring
More informationATEX 94/9/EC Directive Declaration of Conformity: Tips and FAQ s
ATEX 94/9/EC Directive Intertek Deeside Lane, Chester, CH1 6DD UK hazloc@intertek.com +44 1244 882590 www.intertek-hazloc.com Introduction This technical white paper clarifies some of the basic concepts
More informationCONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS
CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS 1.0 DESIGN 1.1 Scope of Work 1.1.1 This work shall consist of furnishing Isolation Bearings and installing Isolation Bearing Assemblies at the locations
More informationDRAFT GUIDANCE DOCUMENT ON THE LOW VOLTAGE DIRECTIVE TRANSITION
EUROPEAN COMMISSION Directorate-General for Internal Market, Industry, Entrepreneurship and SMEs Industrial Transformation and Advanced Value Chains Advanced Engineering and Manufacturing Systems DRAFT
More informationPivotLoc Ladder Systems
N25 ACCESS AND SAFETY EQUIPMENT SPECIFICATION CLAUSES PivotLoc Ladder Systems To be read with The Main Contract Preliminaries, General Conditions, Sub-Contract Preliminaries. MINIMUM CONTRACTOR STANDARD
More informationPRCP CE. Version 5.0 of 16 June 2013. Date of entry into force: 1 July 2013
npo Founded by SECO and BBRI PARTICULAR RULES FOR THE CERTIFICATION OF PRODUCTS AND PRODUCTION CONTROL SYSTEMS WITHIN DE FRAMEWORK OF THE EUROPEAN CONSTRUCTION PRODUCTS REGULATION N 305/2011 PRCP CE Version
More informationFire safety in timber buildings
Fire safety in timber buildings Introduction Fire spread in buildings is a risk to life safety for which the Building Regulations (for England and Wales 1,2, Scotland 3 and Northern Ireland 4 ) aims to
More informationAuthorised and notified according to Article 10 of the Council Directive 89/106/EEC of 21 December 1988 on the
ÖSTERREICHISCHES I N S T I T U T F Ü R B A U T E C H N I K A-1010 Vienna, Schenkenstrasse 4 Tel.: + 4 3 ( 0 ) 1-5 3 3 6 5 5 0 Fax: + 4 3 ( 0 ) 1-5 3 3 6 4 2 3 relating to construction products E - m a
More informationInstitution of Civil Engineers Republic of Ireland Section
Institution of Civil Engineers Republic of Ireland Section : Implementation in Ireland by 2010 Introduction Jim Mansfield Liaison Engineer EN 1990 and EN 1991 Chairman Liaison Engineers Group Institution
More informationHVU with HAS/HAS-E rod adhesive anchor
HVU with HAS/HAS-E rod HVU with HAS/HAS-E rod adhesive anchor Mortar system Benefits Hilti HVU foil capsule HAS HAS-R HAS-HCR rod - suitable for non-cracked concrete C 20/25 to C 50/60 - high loading capacity
More informationFabrication of Reinforcement
Fabrication of Reinforcement 1.0 Introduction The fabrication of reinforcing steels, into shapes suitable for fixing into the concrete formwork, is normally performed 'off-site' in the UK, by specialist
More informationTimber Frame Construction
Timber Frame Construction Introduction Design and Detailing What is timber? Failure modes History of timber frame construction Forms of timber frame construction Live and dead loads Wind loads Roof construction
More informationPage 1 of 18 28.4.2008 Sven Alexander Last revised 1.3.2010. SB-Produksjon STATICAL CALCULATIONS FOR BCC 250
Page 1 of 18 CONTENT PART 1 BASIC ASSUMPTIONS PAGE 1.1 General 1. Standards 1.3 Loads 1. Qualities PART ANCHORAGE OF THE UNITS.1 Beam unit equilibrium 3. Beam unit anchorage in front..1 Check of capacity..
More informationPART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
More informationCHESTERFLEX ROOF WATERPROOFING MEMBRANES
CI/SfB (47) Ln2 Chesterfelt Ltd CHESTERFLEX ROOF WATERPROOFING MEMBRANES Certificate No 94/3062 DETAIL SHEET 2 Product THIS DETAIL SHEET RELATES TO CHESTERFLEX ROOF WATERPROOFING MEMBRANES, POLYESTER REINFORCED
More informationPRODUCT STANDARDS. Electrical Equipment - Requirements for Plugs & Sockets etc
PRODUCT STANDARDS Electrical Equipment - Requirements for Plugs & Sockets etc Guidance notes on the UK Plugs & Sockets etc. (Safety) Regulations 1994 (S.I. 1994/1768) February 2007 URN 07/615 Contents
More informationEuropean Technical Approval ETA-04/0013
ETA-Danmark A/S Kollegievej 6 DK-2920 Charlottenlund Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet www.etadanmark.dk Authorised and notified according to Article 10 of the Council Directive 89/106/EEC
More informationRC Detailing to Eurocode 2
RC Detailing to Eurocode 2 Jenny Burridge MA CEng MICE MIStructE Head of Structural Engineering Structural Eurocodes BS EN 1990 (EC0): BS EN 1991 (EC1): Basis of structural design Actions on Structures
More informationSealfire W1000 Compound. (2 references for the same product) Fire Stopping and Sealing Product: Penetration Seals
UL INTERNATIONAL (UK) LTD Wonersh House, Building C, The Guildway, Old Portsmouth Road, Guildford. GU3 1LR. United Kingdom. Phone : +44 1483 302130 Fax : +44 1483 302230 Email : Inform.NB@uk.ul.com Website
More informationDOCUMENT. Introduction WG2/01 SEPTEMBER 2012. Future CE marking requirements
GUIDANCE DOCUMENT WG2/01 SEPTEMBER 2012 SPECIFYING PERMANENT TRAFFIC SIGNS Introduction ARTSM is the trade body for companies that manufacture and supply traffic signs in the UK. Its members are committed
More informationTFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING
6.CW.1A TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS wood or gas standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING The Fireplace Ltd is able to design and fabricate custom brick open masonry
More informationDiscussion on Products under the Scope of EN 1090-1 and proposed CEN/TR to clarify the scope
CEN/TC 135 N 686 European Committee for Standardization Comité Européen de Normalisation Europäisches Komitee für Normung CEN/TC 135 Execution of steel structures and aluminium structures N 686 Secretariat:
More informationSmartPly OSB3 SMARTPLY
SMARTPLY SmartPly OSB3 SmartPly OSB3 is a highly engineered, moisture resistant load-bearing panel designed for use in humid conditions and is therefore ideal for many structural and non-structural applications
More information