Government of Nepal Ministry of Environment, Science and Technology Alternative Energy Promotion Centre

Size: px
Start display at page:

Download "Government of Nepal Ministry of Environment, Science and Technology Alternative Energy Promotion Centre"

Transcription

1 Government of Nepal Ministry of Environment, Science and Technology Alternative Energy Promotion Centre Nepal Interim PV Quality Assurance (NIPQA) 2005 (Second Revision of NIPQA ) October 2005

2 1 PREAMBLE NEPAL INTERIM PV QUALITY ASSURANCE (NIPQA) December 2000 First Revision: November 2002 Second Revision: September 2005 This technical standard for components of a Solar Photovoltaic (PV) System called Nepal Interim Photovoltaic Quality Assurance (NIPQA) was first developed and adopted by Alternative Energy Promotion Centre/Energy Sector Assistance Programme (AEPC/ESAP) in December 2000 for dissemination of SHS under ESAP. This interim standard was needed due to absence of Nepal Standard (NS) for the components used in PV systems. AEPC/ESAP used the standard to test Solar Home System (SHS) components at the Solar Energy Test Station (SETS) established with investment and technical assistance from AEPC/ESAP and hosted by Royal Nepal Academy for Science & Technology (RONAST). Nepal Bureau of Standard & Metrology (NBSM) and Solar Electric Manufacturers Association Nepal (SEMAN) are the other two promoters of SETS. After two year of its use it was revised in November 2002 through a participatory process. The NIPQA is again revised in September 2005 after two and half year of use and intensive consultations with stakeholders. While the first drafting and first revision had inputs from external consultants, the second revision was done with inputs entirely from within the country. NIPQA has two categories of parameters. The first category is the mandatory parameters for compliance or failure and second category is the recommended ones. The recommended parameters are primarily for quality enhancement through product development. The second revision attempted to incorporate standards for components of larger PV systems (ISPS and PVPS). The second revision dropped the system sizing part entirely to be taken up in separate system sizing guidelines. The second revision also makes the document a national one in contrary to what it started as a standard for one programme. The next step in the process could very much be transforming NIPQA to NS. 2/13

3 2 DEFINITIONS 1. A "Solar Home System" (hereinafter called SHS) is a photovoltaic system used for domestic purposes for providing primarily lighting services. Additional services such as information and entertainment through DC television sets or radios as well as DC fans may also be provided in addition to lighting. 2. An Institutional Solar PV System (hereafter called ISPS) is a DC or AC photovoltaic system used for lighting and power supply to appliances like computer, telephone, refrigerator, etc., in public institutions like VDC buildings, schools, health posts, religious buildings, clubs, etc. 3. A Photovoltaic Pumping System (hereafter called PVPS) is a DC or AC photovoltaic water pumping system operated by photovoltaic electricity to lift water for drinking and drip irrigation purposes. 4. Insolation: Intensity of sunlight measured in kilo-watt-hours in a square metre area in a day (kwh/m 2 /day). 5. Autonomy Days (N): Maximum number of consecutive days where the daily load can be fulfilled without charging the battery, starting the first day with a fully charged battery. 6. Discharge rate: The discharge rate of the battery is expressed as a ratio of the nominal battery capacity to the discharge time period in hours until the final or end voltage of the battery is reached. The usual discharge rates are C 20 or C 10 or C Watt Peak (Wp): Wattage generated by a PV module under a Standard Test Condition (STC) 8. Depth of Discharge (DoD): This is the measure of state of discharge of a battery, where 100% DoD corresponds to a fully discharged battery. 9. State of Charge (SoC): The level of Ampere-hours remaining in the battery until 100% DoD, relative to the C 20 capacity. 10. STC: Standard Test Condition is defined as 1,000 W/m 2 solar radiation in the plane of the array, 1.5 air-mass ratio and 25 o C cell temperature. 11. Critical indicators in charge controller: The indicators displaying the status of battery charging from PV module, normal and low battery charge level. 3/13

4 3 MINIMUM REQUIREMENTS OF COMPONENTS 3.1 PV Module Compulsory: 1. The PV module must be of the Crystalline Silicon Type or the Thin-film Type. Both types of modules need to be certified by a third party agency as per details below: Crystalline silicon PV modules according to the standard - "IEC Crystalline Silicon Terrestrial Photovoltaic (PV) Modules - Design Qualification and Type Approval" or the IEC equivalent national, regional or international standards Thin-film PV modules according to the standard - "IEC Thin-film Terrestrial Photovoltaic (PV) Modules - Design Qualification and Type Approval" or the IEC equivalent national, regional or international standards The IEC equivalent national, regional or international standard must include test of all the IEC certification parameters as per the codes IEC or IEC The national, regional or international testing laboratory must be accredited by the concerned Government body or IEC. 2. A nameplate must be mounted on the PV module frame containing the following details: Brand and name of the manufacturer Model Manufacturer s serial number Maximum power in Watt Peak Open circuit voltage in Volt Short circuit current in Ampere Maximum rated voltage in Volt Maximum rated current in Ampere 3. Electrical parameters of PV Module The deviation of maximum power from its nominal values stated by the manufacturer must not exceed the limit of -10% to +20% (minus 10% to plus 20%) at STC The maximum rated voltage (V mp ) must be at least 16 Volt at STC 4. The PV module of size 40Wp or above must have inbuilt bypass diodes. The modules of any rating to be used for ISPS and PVPS applications must have by pass diodes. 5. The warranty period of Solar PV Module must be at least 10 years against maximum 10% reduction in output power at STC. 3.2 Battery Compulsory: 1. The battery must be deep cycle type of following categories. 4/13

5 a. Vented (open) lead acid battery Flooded Flat plate Tubular plate b. Sealed (valve regulated) lead acid battery Absorbed Glass Mat Gel Flat plate Flat plate Tubular plate 2. The self-discharge of the batteries at 25 C must not exceed 4% of their rated capacity per month (30 days). 3. The operational life cycle of 12 V or 6 V or 2 V battery for flat and tubular plate type must be as follows: For flat plate type, the operational life cycle of 12 V or 6 V battery must be at least 1,800 cycles at 20% DoD and 250 cycles at 80% DoD. For tubular plate type, the operational life cycle of 12 V or 6 V battery must be at least 3,000 cycles at 20% DoD and 1,000 cycles at 80% DoD. For flat plate type, the operational life cycle of 2 V battery must be at least 3,000 cycles at 20% DoD and 1,000 cycles at 80% DoD. For tubular plate type, the operational life cycle of 2 V battery must be at least 3,600 cycles at 20% DoD and 1,200 cycles at 80% DoD. 4. The deviation of battery capacity from its rated capacity stated by the manufacturer must not exceed the limit of -10% to +10% (minus 10% to plus 10%) within 5 cycles of test. 5. The following minimum information must be included in the label of the battery: Brand and name of the manufacturer Model and type Rated capacity in Ampere-hours at the discharge rate C 20 or C 10 or C 5 Nominal voltage in Volt Recommended: 1. The amount of electrolyte should exceed 1.15 litre per cell per 100 Ah nominal capacity at C 20 (20 hours nominal capacity). 2. The initial density of electrolyte to be used in battery should not exceed 1.25 g/cl at 25 o C. 3. The battery should have terminal caps to protect battery terminals from short circuit. 4. ISPS batteries can be installed in series in order to obtain the required DC Voltage for inverter but, 5/13

6 Voltage drop in interconnecting wire should be less than 0.5% of rated voltage. Array of battery should be formed with perfectly matching battery. 5. The battery acid should be certified according to NS standard. 6. The battery water (distilled or de-mineralised or de-ionised water) should be certified according to NS standard. 3.3 Lamp Compact Fluorescent Lamp (CFL) or Tubular Lamp (TL) Compulsory: 1. Luminous yield of the total ballast and fluorescent lamp system must be at least 35 lumens/watt within 15 minutes warm up time after switching on. 2. Reduction in the output (reference lumen) must not exceed 10% after 1,000 on/off cycles and must not exceed 50% after 5,000 on/off cycles. 3. Ballasts must ensure safe and regulated ignition within 10 seconds in the voltage range from 10.3 to 15V over temperature range of 5 o C to +40 o C. 4. The electrical efficiency of the lamp (ballast and tube combined) must be at least 70% at 12 Volt. 5. The lamp must be protected against reverse polarity. 6. Standby consumption (in no-tube condition) of ballast must be less than 20% of rated or nominal capacity (power consumption). 7. The lamp must be operational at an ambient temperature range of 5 o C to +40 o C. 8. The following minimum information must be included in the label of the lamp: Brand name and model Solar PV company name Nominal power in Watt Permitted tube size(s) in Watt Nominal voltage in Volt Size of fuse(s) in Ampere (if applicable) Recommended: 1. The DC component of the current through the fluorescent lamp should be zero. 2. The lamp electronics should not produce radio frequency interference greater than 50 mv/m under any operating circumstances within 2 metres distance. 3. There should not be any voltage spikes on the output wave-shape at the tube terminal. The maximum crest factor should be less than 2.0 over the voltage range from 11V to 12.5V at an ambient temperature of 25 o C 6/13

7 4. The lamp enclosure (housing) should display good workmanship and should provide protection against dust, water, oil, and smoke Tube for Compact Fluorescent Lamp (CFL) or Tubular Lamp (TL) Compulsory: 1. Tube for compact fluorescent lamp (CFL) or Tubular Lamp (TL) must fulfil criteria mentioned in clause LED Cluster Lamp Compulsory: 1. The luminous intensity of individual low power single WLED must not be less than 6000 mcd per WLED at a viewing angle greater than or equal to 2 x 15 o. 2. The luminous intensity of individual high power single WLED must produce at least 6000 mcd of luminous intensity per 100 mw power input at a viewing angle greater than or equal to 2 x 15 o. 3. The luminous efficiency of each individual WLED lamp or cluster of WLEDs must not be less than 15 Lumen/watt within 15 minutes warm up time after switching on. 4. The WLED lamps must be operational for at least 10,000 cycles with reduction in luminous efficiency not exceeding 5% of its initial value (15 Lumen/watt). 5. The lamp must be protected against reverse polarity. 6. The following minimum information must be included in the label of the WLED lamp: Brand name, type (Single or clustered WLED) and model Solar PV company name Nominal power in Watt Nominal voltage in Volt Size of fuse(s) in ma (if applicable) 7. For portable WLED lamps, the combined resistance of wires, switches, sockets (between battery terminals and WLEDs) must not exceed 10 milli Ohms. 8. If more than one WLED is used in lamp assembly, parameters (current and luminous intensity at specified voltage) of individual WLEDs used in the lamp must not differ by more than 10% Recommended: 1. To protect eyes from localised light, proper diffusion system should be incorporated so as to achieve almost uniform light intensity over a solid angle of at least 45 o. 1 The company must provide the ballast for tube testing. 7/13

8 2. The continuous operating life of the WLEDs should not be less than 50,000 hours and it has to be substantiated by the WLED manufacturer s claim sheet. 3. The Colour Rendering Index (CRI) of the WLEDs should be not less than The lamp enclosure (housing) should display good workmanship and should provide protection against dust, water, oil, and smoke Lamps used in Solar Lanterns Compulsory: 1. For Solar Lanterns to be used in Solar Home System, the lamps used in Lanterns must meet the standards mentioned in clause no or AC Lamp for ISPS Compulsory: 1. For ISPS with an inverter, lamps must be AC 220V and 50 Hz operated CFL or TL. 2. Lamp must ensure safe and regulated ignition between 220 V ±10% and 50 Hz ±2%. 3. The lamps used, must fulfil criteria 1, 2, 6, 7 & 8 mentioned in clause Charge Controller Compulsory: 1. The charge controller must function in accordance with Pulse Width Modulation (PWM) or On/Off working principles. 2. Deep discharge protection must be included and option for manual de-activation of the deep-discharge protection is not permitted. Low Voltage Disconnection (LVD) for flat plate battery must not be less than 11.8 Volt and for tubular plate battery LVD must not be less than 11.4 Volt and the setting must be within ± 2% of the manufacturer s claim at 25 o C. 3. Low Voltage Reconnection (LVR) must not be less than 12.5 Volt and the setting must be within ± 2% of the manufacturer s claim at 25 o C. 4. Over-charge protection must be included. High Voltage Disconnection (HVD) must be within range of 14 Volt to 14.8 Volt and the setting must be within ± 2% of the manufacturer s claim at 25 o C. 5. High Voltage Reconnection (HVR) must be greater than 13.5V and the setting must be within ± 2% of the manufacturer s claim at 25 o C. 6. Usage of electro-mechanical relay is not permitted. 7. The quiescent current consumption must not exceed 7 ma at nominal system voltage while the non-critical indicators are turned off. 8/13

9 8. For 12 V systems, voltage drop across the charge controller while charging (PV panel to battery terminals) must not exceed 1 V and while discharging (battery to load terminals) must not exceed 0.5 V. For 24 V systems, voltage drop across charge controller while charging must not exceed 2 V and while discharging must not exceed 1 V. For 48 V systems, voltage drop across charge controller must not exceed 4 V during charging and must not exceed 2 V during discharging. 9. The charge controller must withstand at least 90% of rated current from the PV module to battery and from battery to load at an ambient temperature range of 5 o C to 40 o C. 10. Protection against reverse polarity must be provided in both the PV module and battery sides. 11. Reverse leakage current must be less than 500 micro-amperes (current from battery to dark module) 12. The following minimum information must be included in the label of the charge controller: Brand name, type (On/Off or PWM) and model Solar PV company name Maximum input current in Ampere Maximum load current in Ampere Nominal voltage in volt Size of fuse(s) in Ampere (if applicable) Type of battery to be used 13. The type of charge controller according to battery type (flat plate or tubular plate) must be printed in front cover of the charge controller as part of its specifications. 14. For ISPS, all criteria are valid except criteria No. 2, 3, 4 & 5 where the value of LVD, LVR, HVD and HVR must be multiplied by factor N. Here N stands for the number of batteries in a series connection Recommended: 1. The charge controller should not produce radio frequency interference greater than 50mV/m within 2 metres distance. 2. Charge controller boxes should display good workmanship and should provide protection against dust, water, oil, and smoke. 3. For sealed batteries, High Voltage Disconnection (HVD) set point should not exceed 14 Volt. 4. The charge controller should have protection against the effect of temperature and humidity variation. In high mountain areas, it is recommended to use charge controller having following properties to minimize the effect a. Sealed type b. Epoxy encapsulation in PCB 9/13

10 c. Large surface area PCB board with sufficient gap between electronic components. 5. The smaller systems (less than 5 Wp) using other types of batteries should omit the charge controllers from the system. 3.5 Support Structure for PV Modules Compulsory: 1. Support frame structures must be made of stainless steel, aluminium, galvanised iron or electroplated iron and must be able to withstand wind speeds of min. 85 km/h so as to be able to resist at least 20 years of outdoor exposure without suffering significant damage or corrosion. 2. Mounting pole must be made of stainless steel, aluminium, galvanised iron, electroplated iron or wood and must be able to withstand wind speeds of min. 85 km/h so as to be able to resist at least 20 years of outdoor exposure without suffering significant damage or corrosion. 3.6 Cables Compulsory: 1. The cables used must be certified according to the standard "NS for PVC insulated copper conductor cables for fixed wiring. 2. Cable sections, which are used out door, especially between the PV module and charge controller must be waterproof and UV resistant. 3. Cables must be colour coded in accordance with the existing electric coding norms. 3.7 Switches, Sockets And Protections Compulsory: 1. Switches must be certified according to the standard NS or "IS 3854 Switches for Domestic and Similar Purpose. 2. DC sockets must be used with a reverse polarity protection. 3.8 Inverter Compulsory: 1. The Inverter must have a rated AC output voltage of 220V ± 10% at battery operating voltage from DC 90% to 120% and load current from 10% to 110% of the rated value. 2. The quiescent current drawn by the inverter must not exceed 3% of the rated input current of the inverter. 3. Inverter or Inverter circuits must include: 10/13

11 Low battery shut down must be at battery voltage not less than 11.8 V for flat plate battery and not less than 11.4 V for tubular plate battery in case of 12 V systems. For 24 V or 48 V systems, low battery shut down voltage must be multiplied by factor N. Here N stands for the number of batteries in a series connection. Short-circuit protection of input and output terminals Reverse polarity protection on DC input terminals 4. Complete documentation for the inverter including the following must be provided: Installation instructions Operating instructions Technical specification and ratings Safety warnings Troubleshooting instructions Information pertaining to the serviceable parts Warranty 5. The minimum information must be included in the label of the inverter: Manufacturers name and model Solar PV company name Rated power in Watt or VA Input and output voltage in Volt Battery connection points & polarity and AC outlet points 6. The inverter input and output terminals must not be exposed to contact by the user. 7. Output frequency must be 50Hz ± 2%. 8. For sine wave inverters, the output waveform s Total Harmonic Distortion (THD) must be less than 5%. 9. Inverter efficiency when operating resistive loads at power levels within 10% to 90% of rated load must be greater than 80%. 10. Inverter must be capable of Operating continuously for at least 4 hours at its rated power under ambient temperature up to 40 C Operating safely for at least one minute at 125% of rated power; Operating safely for at least two seconds at 200% of rated power Recommended: 1. The inverter should automatically switch to sleep mode where there is no consumption for 5 minutes. 11/13

12 2. The audible noise produced by the inverter should not be more than 65 db at a distance of 3 metres from the inverter. 3. Inverter or Inverter circuits should include: Low battery alarm Over temperature Protection Protection against lightning induced transients. 4. There should be no radio interference greater than 50 mv/m at a distance of 3 metres under all operating conditions. 3.9 Solar Pump for PVPS Compulsory 1. The wire to water efficiency of motor- pump unit must be at least 30%. 2. The following minimum information must be included in the catalogue of the pump: Manufacturer name and model Nominal voltage in Volt Wire to water efficiency Maximum head in metre Maximum flow rate 3. The motor-pump set must include protection against Dry run Sand and silt Reverse polarity (for DC motor-pump set) 3.10 Solar Vaccine Refrigerator for ISPS Compulsory: 1. The solar vaccine Refrigerator must be certified in accordance to WHO standards Grounding for ISPS and PVPS Compulsory: 1. All metallic enclosures and structures of the system must be bonded and grounded using the shortest practical route to an adequate earth contact using an uninterrupted conductor of at least 16 mm 2 cross-section. 12/13

13 2. The earth resistance must not exceed 10 Ohms with the bonding resistance 2 not exceeding 0.2 Ohms Other Loads for ISPS Recommended: 1. The loads connected to ISPS should be energy efficient as far as possible. 4 QUALITY TESTING The Solar Energy Test Station (SETS) or any other national test lab or a reputed third party testing lab accredited by the appropriate authority and accepted by AEPC, should carry out the quality test of the components according to the above mentioned and referred technical standards. Approved on October 2005 by (Signed) (Dr. Madan Bahadur Basnyat) Executive Director, AEPC Office Seals 2 Between the metal parts of the devices and metal parts of the consumer earth terminal. 13/13

Renewable Energy Test Station (RETS) TEST PROCEDURES FOR SOLAR TUKI

Renewable Energy Test Station (RETS) TEST PROCEDURES FOR SOLAR TUKI Renewable Energy Test Station (RETS) TEST PROCEDURES FOR SOLAR TUKI March 2007 A. Test Procedures for Solar Tuki Lamp S. No. Test Parameters Technical Requirements Instruments Required Test Methods A.

More information

NEPAL PHOTOVOLTAIC QUALITY ASSURANCE (NEPQA) 2015.rev1

NEPAL PHOTOVOLTAIC QUALITY ASSURANCE (NEPQA) 2015.rev1 NEPAL PHOTOVOLTAIC QUALITY ASSURANCE (NEPQA) 2015.rev1 Preamble This technical standard for components of a Solar Photovoltaic (PV) System, called Nepal Photovoltaic Quality Assurance (NEPQA), was first

More information

Ministry of New and Renewable Energy. Jawaharlal Nehru National Solar Mission SOLAR PHOTOVOLTAIC WATER PUMPING SYSTEMS (2015-16)

Ministry of New and Renewable Energy. Jawaharlal Nehru National Solar Mission SOLAR PHOTOVOLTAIC WATER PUMPING SYSTEMS (2015-16) Ministry of New and Renewable Energy Jawaharlal Nehru National Solar Mission SOLAR PHOTOVOLTAIC WATER PUMPING SYSTEMS (2015-16) I. INTRODUCTION A Solar Photovoltaic (SPV) Water Pumping System consists

More information

CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN

CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN 5.1 Introduction So far in the development of this research, the focus has been to estimate the available insolation at a particular location on the earth s surface

More information

32/1/2013-14/PVSE(Part-II) Ministry of New and Renewable Energy SPV Off Grid Division

32/1/2013-14/PVSE(Part-II) Ministry of New and Renewable Energy SPV Off Grid Division Annexure-A 32/1/2013-14/PVSE(Part-II) Ministry of New and Renewable Energy SPV Off Grid Division Scheme: Installation of 10,000 nos. of solar photovoltaic water pumping systems for irrigation purpose implemented

More information

User s Manual Before using the inverter, you need to read and save the safety instructions.

User s Manual Before using the inverter, you need to read and save the safety instructions. User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information

More information

Introduction for Photovoltaic Power System Test in China. Zou Xinjing Institute of Electrical Engineering Chinese Academy of Sciences Nov.

Introduction for Photovoltaic Power System Test in China. Zou Xinjing Institute of Electrical Engineering Chinese Academy of Sciences Nov. Introduction for Photovoltaic Power System Test in China Zou Xinjing Institute of Electrical Engineering Chinese Academy of Sciences Nov. 6, 2012 Content Testing Status of PV power systems in China Test

More information

AJ s Technical Tips: Designing a Small Solar PV System Part IV; Selecting Wires for the System

AJ s Technical Tips: Designing a Small Solar PV System Part IV; Selecting Wires for the System AJ s Technical Tips: Designing a Small Solar PV System Part IV; Selecting Wires for the System A little while back Simon Nyukuri of Kitale wrote to ask me about sizing wires and cables for solar PV systems.

More information

BB800 Off-Grid Solar System

BB800 Off-Grid Solar System BB800 Off-Grid Solar System KEY PRODUCT FEATURES Control Box & Charge Controller 1000W of Solar Panels 4x200Ah of SLA Batteries in series 2KW Inverter Output Power Solar Panel & Battery Mounting Our entry

More information

Battery Power Inverters

Battery Power Inverters Battery Power Inverters Renogy 500W 1000W 2000W Pure Sine Wave Inverter Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 1 Version 1.1 Important Safety Instructions Please save these instructions.

More information

12 Volt 30 Amp Digital Solar Charge Controller

12 Volt 30 Amp Digital Solar Charge Controller 12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions

More information

Solar Powered Wireless Sensors & Instrumentation: Energy Harvesting Technology Reduces Operating Cost at Remote Sites

Solar Powered Wireless Sensors & Instrumentation: Energy Harvesting Technology Reduces Operating Cost at Remote Sites Solar Powered Wireless Sensors & Instrumentation: Energy Harvesting Technology Reduces Operating Cost at Remote Sites Standards Certification Education & Training Publishing Conferences & Exhibits Michael

More information

User s Manual AURORA 1.2K/2.2K

User s Manual AURORA 1.2K/2.2K User s Manual AURORA 1.2K/2.2K Uninterruptible Power System Safety CAUTION This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable

More information

How To Use A Power Supply Unit (Upu)

How To Use A Power Supply Unit (Upu) BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.

More information

The Basics of Solar Power for Producing Electricity An excellent place to start for those just beginning. The basics of solar power: 1000 W/m²

The Basics of Solar Power for Producing Electricity An excellent place to start for those just beginning. The basics of solar power: 1000 W/m² The Basics of Solar Power for Producing Electricity Learn the essential basics of using solar power so you can understand your project. Planning your project begins with understanding the basics found

More information

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

What are the basic electrical safety issues and remedies in solar photovoltaic installations? What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety Topics Covered Photovoltaic

More information

LD200-12 Operating Manual S A S A ELECTRONIC USTRALIA ELECTRONIC USTRALIA. Notes

LD200-12 Operating Manual S A S A ELECTRONIC USTRALIA ELECTRONIC USTRALIA. Notes Notes LD200-12 Operating Manual Serial No Purchase Date S A ELECTRONIC USTRALIA Part No ST-M-LD200 Rev 4 18/11/04 Note - Your 2 Year Warranty can only be valid once your warranty card is completed and

More information

USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018

USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018 USER S MANUAL MaxPower 400-600 UPS Uninterruptible Power System 28-2MAXPO0018 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models MaxPower 400 and

More information

Online UPS. PowerWalker VFI 1000R/1U

Online UPS. PowerWalker VFI 1000R/1U Online UPS PowerWalker VFI 1000R/1U Manual Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation... 1 1-4.

More information

Photovoltaic Solar Energy Unit EESFB

Photovoltaic Solar Energy Unit EESFB Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality

More information

Solar power Availability of solar energy

Solar power Availability of solar energy Solar Energy Solar Energy is radiant energy produced in the sun as a result of nuclear fusion reactions. It is transmitted to the earth through space by electromagnetic radiation in quanta of energy called

More information

Stand Alone PV System Sizing Worksheet (example)

Stand Alone PV System Sizing Worksheet (example) Stand Alone PV System Sizing Worksheet (example) Application: Stand alone camp system 7 miles off grid Location: Baton Rouge, La Latitude: 31.53 N A. Loads A1 Inverter efficiency 85 A2 Battery Bus voltage

More information

TruPower-Portable-500W. Solar Starter kit

TruPower-Portable-500W. Solar Starter kit TruPower-Portable-500W Solar Starter kit This Solar starter kit is an easy to use solar power supply system that is the complete solution for all your solar power needs. It is a solar generator that converts

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS 1. Standards BOS Item / System I ii iii TECHNICAL SPECIFICATIONS Applicable BIS /Equivalent IEC Standards / Applicable MNRE Specifications Standard Description Standard Number Crystalline Silicon Terrestrial

More information

Mobile Data Power Model: MDP-25

Mobile Data Power Model: MDP-25 Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss

More information

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting 12 SOLAR PHOTOVOLTAIC POWER by John Ware IT IS PLANNED for BS 7671:2008 to include a new Section 712 providing additional requirements for safety applicable to solar photovoltaic (pv) power supply systems.

More information

Charge Regulator SCR 12 Marine

Charge Regulator SCR 12 Marine Charge Regulator SCR 12 Marine Manual Many thanks for purchasing a superwind product. The SCR 12 Marine is a charge regulator of highest quality and will perfectly and reliably charge your batteries for

More information

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification 08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and

More information

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,

More information

Additional Solar System Information and Resources

Additional Solar System Information and Resources Additional Solar System Information and Resources Background information a. Roughly 400 schools in NJ already have solar systems, producing more than 91 MW, out of approximately 2500 K- 12 schools in NJ.

More information

Installation Guide of Sunrise Solartech PV Modules. Term 2013. Contents. Purpose of this guide. General. Safety precaution for installing a solar

Installation Guide of Sunrise Solartech PV Modules. Term 2013. Contents. Purpose of this guide. General. Safety precaution for installing a solar Installation Guide of Sunrise Solartech PV Modules Term 2013 Contents Purpose of this guide General Safety precaution for installing a solar Photovoltaic system Product Identification Mechanical Installation

More information

PV (photovoltaic) Basics There are generally two types of PV systems. The first and easiest (though the least flexible) is a grid tie system where

PV (photovoltaic) Basics There are generally two types of PV systems. The first and easiest (though the least flexible) is a grid tie system where PV (photovoltaic) Basics There are generally two types of PV systems. The first and easiest (though the least flexible) is a grid tie system where the power generated by the solar panel (panels) runs an

More information

VLT Series 300 Watt True Sine Wave Inverter

VLT Series 300 Watt True Sine Wave Inverter VLT Series 300 Watt True Sine Wave Inverter PURE SINE WAVE INVERTER I ON 0 OFF REMOTE CONTROL AC OUTPUT POWER STATUS Vout Vin Models VLT12-300 VLT24-300 300 Watt VLT Series Inverter - 1 - TABLE OF CONTENTS

More information

ST Series POWER SUPPLIES USER INSTRUCTIONS

ST Series POWER SUPPLIES USER INSTRUCTIONS Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional

More information

TIG INVERTER INSTRUCTION MANUAL

TIG INVERTER INSTRUCTION MANUAL TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4

More information

Solar Home System Kit Quality Standards

Solar Home System Kit Quality Standards Solar Home System Kit Quality Standards Version 1 December 2015 Lighting Global has expanded the quality assurance framework to cover solar home system kits. This document describes the Quality Standards

More information

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS Capacity Technology Inverter Technology Noise Level Operating Temperature Humidity Harmonic Distortion Total DC bus voltage Battery recharge time (After Complete discharge) to 100% charge Crest Factor

More information

SHARP SOLAR Frequently Asked Questions for PV Integrators Revised 05/04/2010

SHARP SOLAR Frequently Asked Questions for PV Integrators Revised 05/04/2010 SHARP SOLAR Frequently Asked Questions for PV Integrators Revised 05/04/2010 How do I determine the PTC rating of a module? PTC refers to PVUSA Test Conditions, which were developed to test and compare

More information

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger Digital echo-charge Owner s Manual Xantrex Digital echo-charge Battery Charger Thank you for purchasing a Xantrex Digital echo-charge. Xantrex Technology Inc. takes pride in manufacturing quality products

More information

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product! EPSOLAR LS0512R / LS0524R Solar Light Controller INSTRUCTION MANUAL Please read this manual carefully before using the product! LandStar LS0512R / LS0524R Solar Light Controller Nominal system voltage

More information

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5 White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code June 2015 Revision 1.5 Shalhevet Bar-Asher; SolarEdge Technologies, Inc. Bill Brooks, PE; Brooks Engineering LLC

More information

When Do Solar Electric & Utility Back-Up Systems Make Sense?

When Do Solar Electric & Utility Back-Up Systems Make Sense? When Do Solar Electric & Utility Back-Up Systems Make Sense? Oil & Gas Industry Presentation Proprietary Information 2010 SunWize Technologies When Do Solar Electric and Utility Back-Up Systems Make Sense?

More information

Solar Wind Microhydro Water Pumping Inverters Batteries Professional system design and installation

Solar Wind Microhydro Water Pumping Inverters Batteries Professional system design and installation Solar Wind Microhydro Water Pumping Inverters Batteries Professional system design and installation BATTERY CHARGING GUIDELINES FOR GLOBAL/DAVIDSON TUBULAR PLATE BATTERIES Introduction Your Global/Davidson

More information

SPECIFICATIONS. Recommended Battery sizes (Maintenance) AUTOMOTIVE 150 650CCA 150 750CCA MARINE 200 700MCA 200 850MCA DEEP CYCLE 17 55Ah 17 80Ah

SPECIFICATIONS. Recommended Battery sizes (Maintenance) AUTOMOTIVE 150 650CCA 150 750CCA MARINE 200 700MCA 200 850MCA DEEP CYCLE 17 55Ah 17 80Ah WARNING Read the operating instructions before use. Lead Acid Batteries can be dangerous. Ensure no sparks or flames are present when working near batteries. Eye protection should be used. Make sure the

More information

Installation Instructions for Solar Pumps USER MANUAL FOR SPS, SPC, SPSC SPQB, SPGJ SERIES SOLAR PUMPS AND PUMP CONTROLLERS

Installation Instructions for Solar Pumps USER MANUAL FOR SPS, SPC, SPSC SPQB, SPGJ SERIES SOLAR PUMPS AND PUMP CONTROLLERS Installation Instructions for Solar Pumps USER MANUAL FOR SPS, SPC, SPSC SPQB, SPGJ SERIES SOLAR PUMPS AND PUMP CONTROLLERS PO Box 80, Tuakau 2342 ph 0800 14 48 65 e-mail: hunkin-garden@xnet.co.nz www.hunkin.co.nz

More information

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual 12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual This 30Amp charge controller is designed to protect your 12Volt Lead-acid or Gel-cell battery from being overcharge by solar

More information

ANTENERGY. Powered By BOSCH Cells Portable Solar Panel Kit. User Manual and Product Specifications

ANTENERGY. Powered By BOSCH Cells Portable Solar Panel Kit. User Manual and Product Specifications ANTENERGY Powered By BOSCH Cells Portable Solar Panel Kit User Manual and Product Specifications IMPORTANT Read instructions before operation. 1 / 12 Index Getting to know your Portable Solar Panel Kit

More information

PHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V

PHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V PHOTOVOLTAIC SYSTEM CONTROLLERS OPERATOR S MANUAL SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V 6A / 12V 10A / 12V 10A / 24V 20A / 12V 20A

More information

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 Technical information Version: 07.14 General Function The speed sensors family DSD.70 are suitable for generating

More information

Thyristor-controlled power supplies and battery chargers

Thyristor-controlled power supplies and battery chargers Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /

More information

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power: PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV

More information

Your Sharp system will be supplied with one of the following sets of panels:

Your Sharp system will be supplied with one of the following sets of panels: Sharp3000 3kW Solar System Panel Specifications Your Sharp system will be supplied with one of the following sets of panels: Manufacturer Mono Or Poly Size (Watts) Panels Required To Achieve Minimum 3000

More information

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps Solar Home System User Manual AEHSHS0110W2L Solar Home System 2 Lamps All rights reserved Specifications subject to change without prior notice 2 Dear Customer, Thank you for purchasing Schneider Electric

More information

LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems

LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems A. General This Net Metering Standard for Customer-Owned Grid Connected Electric Generating Systems sets forth the

More information

Constant Voltage Charger Selection for VRLA Batteries

Constant Voltage Charger Selection for VRLA Batteries TECHNICAL BULLETIN 41-2129 Constant Voltage Charger Selection for VRLA Batteries Please Note: The information in this technical bulletin was developed for C&D Dynasty 12 Volt VRLA products. While much

More information

12 Volt Lighting Products

12 Volt Lighting Products Low voltage DC bulbs are the most efficient light sources for using electrical energy produced with photovoltaic, wind and small hydro power systems. With low voltage DC lights, there are no power penalties

More information

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

REGULINE 600VA / 1000VA REGULATOR USER MANUAL REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate

More information

3000W Power Inverter

3000W Power Inverter 3000W Power Inverter OWNER S MANUAL Model number-4573000 TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND THIS INSTRUCTIONAL MANUAL. THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING THE

More information

Design qualification and type approval of PV modules

Design qualification and type approval of PV modules Design qualification and type approval of PV modules TÜV Immissionsschutz und Energiesysteme GmbH Test Centre for Energy technologies May 2003 Design qualification and type approval of PV-modules in accordance

More information

Charger Output AC Ripple Voltage and the affect on VRLA batteries

Charger Output AC Ripple Voltage and the affect on VRLA batteries TECHNICAL BULLETIN 41-2131 Charger Output AC Ripple Voltage and the affect on VRLA batteries Please Note: The information in this technical bulletin was developed for C&D Dynasty 12 Volt VRLA products.

More information

ENGLISH USER MANUAL. Victron Atlas Combi 12/450. victron energie. user manual 5

ENGLISH USER MANUAL. Victron Atlas Combi 12/450. victron energie. user manual 5 ENGLISH USER MANUAL Victron Atlas Combi 12/450 user manual 5 INTRODUCTION Victron Energie has established an international reputation as a leading designer and manufacturer of power systems. Our R&D department

More information

Section III Schedule of Requirements TECHNICAL SPECIFICATIONS OF THE REQUIRED SYSTEMS

Section III Schedule of Requirements TECHNICAL SPECIFICATIONS OF THE REQUIRED SYSTEMS PART III TECHNICAL SPECIFICATIONS OF THE REQUIRED SYSTEMS I. GENERAL The objective of this specification is to describe a system which uses solar energy to produce electricity. For each site (lot) one

More information

Match. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Match. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy. Match Uninterruptible Power Supply 500-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com

More information

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL 16350 TYPE 12/24EL40-10ET

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL 16350 TYPE 12/24EL40-10ET LESTRONIC DV AUTOMATIC 12 OR 2 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL 16350 TYPE 12/2EL0-10ET PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING INSTRUCTIONS For correct operation of the equipment,

More information

Tamura Closed Loop Hall Effect Current Sensors

Tamura Closed Loop Hall Effect Current Sensors Tamura Closed Loop Hall Effect Current Sensors AC, DC, & Complex Currents Galvanic Isolation Fast Response Wide Frequency Bandwidth Quality & Reliability RoHs Compliance Closed Loop Hall Effect Sensors

More information

MANUAL D250S DUAL. Solar panel + Vehicle ground/solar panel

MANUAL D250S DUAL. Solar panel + Vehicle ground/solar panel MANUAL CONGRATULATIONS on the purchase of your new CTEK professional battery management unit. This unit is part of a range of professional battery chargers from CTEK SWEDEN AB. It represents the latest

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6 User s manual Index Safety Warnings... 2 1 Introduction... 3 2 General Characteristics... 4 3 Receipt and site selection... 4 4 EXTERNAL

More information

Failure code manual. content

Failure code manual. content Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

26 3213.13 Diesel Engine Driven Generators Page 1 of 6

26 3213.13 Diesel Engine Driven Generators Page 1 of 6 Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at

More information

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

A reasonable, new furnace (mid efficiency) has the following electrical requirements: June 2007 Power Backup Systems for Your Home. As promised from a previous safety meeting, a couple of options to protect you home in the event of a power failure. These options are for the most serious,

More information

SOLAR PV SYSTEM MAINTENANCE GUIDE

SOLAR PV SYSTEM MAINTENANCE GUIDE SOLAR PV SYSTEM MAINTENANCE GUIDE GUYANA HINTERLANDS STAND-ALONE SOLAR PV INSTALLATIONS IMPROVING HEALTH FACILITY INFRASTRUCTURE (IHFI) GUYANA CONTRACT NO. EPP-I-00-03-00008-00, TASK ORDER 07 APRIL 2013

More information

Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD)

Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD) Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD) Note: This guidance document is a translation of official Chinese document which is issued by CQC (China Quality Certification Center) on

More information

ADDENDUM #1(BID PACKAGE # 3)

ADDENDUM #1(BID PACKAGE # 3) H2Engineering, Inc. 114 East Fifth Avenue Tallahassee, FL 32303 Phone 850.224.7922 Fax 850.224.5876 ADDENDUM #1(BID PACKAGE # 3) To: Jeff Williams From: Peter Lindstrom Co: Leon County Date: October 04,

More information

victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850

victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850 victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850 SECTIONS ENGLISH 1 NEDERLANDS 27 DEUTSCH 55 This page intentionally left blank. ENGLISH USER MANUAL Victron Atlas

More information

MAJORSINE Power Inverter

MAJORSINE Power Inverter MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions

More information

Technical Data. back-up time in minutes 100% load 6 7 0 5 6 0 5 0 50% load 15 18 0 15 16 0 15 0

Technical Data. back-up time in minutes 100% load 6 7 0 5 6 0 5 0 50% load 15 18 0 15 16 0 15 0 The protectoq is a On-Line double conversion UPS-system according to IEC / EN 62040-3 (VFI-SS-111) with sinus wave output voltage in each operation mode, LCDindication, RS232 interface, USB-connection,

More information

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault

More information

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers Technical Note Freedom/Fleet Power 512-0084-01-01 Rev 1 Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers Overview This document is a guide for troubleshooting inverters, battery chargers,

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

RADIANT PLASMA 4700 Plasma Spark Generator

RADIANT PLASMA 4700 Plasma Spark Generator RADIANT PLASMA 4700 Plasma Spark Generator Installation Guide / User Manual A S P A R K O F F R E S H A I R Aquapulser.com Contents 1 Introduction 2 1.1 About the Product....................................

More information

Kit 27. 1W TDA7052 POWER AMPLIFIER

Kit 27. 1W TDA7052 POWER AMPLIFIER Kit 27. 1W TDA7052 POWER AMPLIFIER This is a 1 watt mono amplifier Kit module using the TDA7052 from Philips. (Note, no suffix.) It is designed to be used as a building block in other projects where a

More information

AutoRanging Digital MultiMeter

AutoRanging Digital MultiMeter Owner's Manual AutoRanging Digital MultiMeter Model No. 82139 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. PSDC 08128 v.1.2 PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. EN** Edition: 9 from 25.05.2015 Supersedes the edition: 8 from 12.12.2014 the 8x 1A/12V DC power output for powering

More information

Specifying a Variable Frequency Drive s

Specifying a Variable Frequency Drive s Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable

More information

www.ringautomotive.co.uk Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

www.ringautomotive.co.uk Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A SmartChargePro7 RSCPR7-12v, 7A SmartChargePro10 RSCPR10-12v, 10A SmartChargePro15 RSCPR15-12v, 15A SmartChargePro25 RSCPR25-12v, 2 / 6 / 12 / 25A SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A SmartChargePro50

More information

Solar Powered Smart Irrigation System

Solar Powered Smart Irrigation System Advance in Electronic and Electric Engineering. ISSN 2231-1297, Volume 4, Number 4 (2014), pp. 341-346 Research India Publications http://www.ripublication.com/aeee.htm Solar Powered Smart Irrigation System

More information

Power consumption (kw)

Power consumption (kw) OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components

More information

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W T5 TC-DEL TC-SEL TC-TEL TC-DD PC BASIC, 4 28 W Electronic ballast for system output < 25 W Product description CELMA Energy Efficiency Index A2 / A3 Nominal life time up to 50,000 h (at ta 50 C with a

More information

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines On customer request it is possible to supply: Benches for PCB Oven for PCB Chemicals

More information

13 Watt PORTABLE SOLAR POWER KIT

13 Watt PORTABLE SOLAR POWER KIT 3 Watt PORTABLE SOLAR POWER KIT User s Manual Thank you for purchasing a Sunforce Portable Solar Power Kit. Please read these instructions carefully and thoroughly before using the product. Your new Portable

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

Fundamentals of Power

Fundamentals of Power Fundamentals of Power Fundamentals of Power 2008 American Power Conversion Corporation. All rights reserved. All trademarks provided are the property of their respective owners. Learning Objectives At

More information

City of Leesburg, Florida I.T. Data Center 130551 APPENDIX A TOSHIBA UPS INFORMATION

City of Leesburg, Florida I.T. Data Center 130551 APPENDIX A TOSHIBA UPS INFORMATION City of Leesburg, Florida I.T. Data Center 130551 APPENDIX A TOSHIBA UPS INFORMATION This Appendix A includes technical documents and specifications for the Toshiba 4200 FA 30 kva Uninterruptable Power

More information

BEIJING EPSOLAR TECHNOLOGY CO.,LTD.

BEIJING EPSOLAR TECHNOLOGY CO.,LTD. WITH TWO BATTERY CHARGING EPSOLAR s duo-battery charging solar controller, For RVs, Caravans,and boats. Adjust options: 1. Battery type selection. 2. Two battery charging priority(from 0-100%) 3. Charging

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled M BASIC 1 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing SEV for output voltage < 60 V DC ow-profile casing (21 x 30 mm cross-section) 5-year

More information

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES Gas explosion protection II 2G Ex d IIC T6 Gb (suitable for Zone1 and Zone 2) Dust explosion protection II 2D Ex tb IIIC

More information

Wolflite Safety Handlamp H-251E

Wolflite Safety Handlamp H-251E Wolflite Safety Handlamp H-251E & H-251 Mk1 & Mk2 Wolflite Safety Handlamp H-251E H 18Y H 17 H 31Y H 21A H 30 H 24 H 26 H 19 H 25 H 03 H 15Y H 22 H 104 H 29 H 66 H 13 H 14 H 09 H 12 H 48 H 11 H 62 H 63

More information