A V K I N T E R N A T I O N A L A / S

Size: px
Start display at page:

Download "A V K I N T E R N A T I O N A L A / S"

Transcription

1 A V K I N T E R N A T I O N A L A / S Va l v e s & H y d r a n t s f o r F i r e F i g h t i n g U L / U L C L i s t e d a n d F M A p p r o v e d

2 2 AVK Builds Long Life and Good Economy into your Fire Fighting Systems Fire plays a decisive part in our developement as human beings. Under control it is invaluable, but out of control it can be devastating. Brave firemen risk their lives to extinguish fires. They rely fully on their equipment to function perfectly when needed. Therefore it is crucial that the products installed are highly reliable, are easy to maintain and last a lifetime. AVK is a leading suppliers of high quality hydrants and valves for fire fighting and sprinkler systems. Our unique design and wide product range is based on the needs of customers worldwide. We offer a wide range of high quality valves and hydrants which, along with a series of accessories, build the optimum solution. The complete fire fighting package complies with international standards and consists of hydrants, NRS post indicator valves, hand wheel operated OS&Y gate valves, post and wall indicators, all UL/ULC listed and. Furthermore AVK holds VDS approval for NRS hand wheel operated gate valves. Hydrants to AWWA Standard Series 24 Wet barrel fire hydrant Series 27 Dry barrel fire hydrant, modern style Dry barrel fire hydrant, nostalgic style Post Indicators to UL and FM Standard Series 34 Post indicator Wall post indicator Valves to DIN Standard Series 06/35 Gate valve with position indicator Valves to AWWA Standard Series 25 Gate valve for post indicator Gate valve with rising stem Series 45 Gate valve

3 Accessories 3 for Hydrants and Valves A wide range of accessories helps completing the wide product package from AVK. If luck runs out it is crucial that the products can be repaired quickly and efficiently without any down time. Maintenance and repair shall be completed without the use of special tools. Besides repair kits for our hydrants AVK has of a number of accessories, such as extension spindles, street covers and different stem caps, which supplements and completes our high quality valves and hydrants. Accessories to AWWA Standard Accessories to AWWA Standard Accessories to DIN Standard Accessories to DIN Standard Series 24 Breakable flange unit for wet barrel hydrants Break ring repair kit for wet barrel hydrants Series 27 Tools for dry barrel hydrants Extension kit for dry barrel hydrants Traffic section repair kit for dry barrel hydrants Series 04 Stem caps for gate valves and service connection valves - DN GG-25 Series 08 Hand wheel for gate valves - DN GG-25

4 4 D r y b a r r e l h y d r a n t s S e r i e s 2 7 a n d S e r i e s 2 4 Series 27/00 dry barrel fire hydrant is primarily designed for frost areas, where the water main is located below ground frost zone. The series 27/00 dry barrel hydrant has two drain outlets located just above the water main level. The main valve disc is designed with the purpose of flushing the drain channels for soil and other impurities during opening. These impurities could lead to damage of the main valve disk. After turning the operation key 2 to 3 times the drain will stop flushing and the barrel will be filled with water, which will flow directly into the hoses and pumper hose or whatever is connected. Furthermore when the hydrant is closed after service the barrel will drain the water through the drain holes in the base. Therefore it is important to make sure that the base is surrounded by gravel allowing the hydrant to drain and flush without washing off the soil. If not, this could result in undermining of the pavement. Series 24 wet barrel fire hydrant is designed for non frost areas. The series 24 wet barrel hydrant is designed with the shut-off device directly at the outflow nozzle for hose or pumper connection. This means that the hydrant is constantly filled with water and thus under pressure. The hydrant is mounted directly on the water main, giving full water pressure instantaniously when needed. Only after 1/8 turns on the stem the water starts to flow, and after 12 turns the full flow capacity can be held against the fire. The hydrant is not for use where the temperature may come below 0 C, due to the risk of frost bursting. In order to service and maintain the hydrant, we recommend installing an isolating gate valve on the upstream side.

5 AV K D r y B a r r e l F i r e H y d r a n t s a r e 5 D e s i g n e d f o r H i g h P e r f o r m a n c e AVK dry or wet barrel fire hydrants meet or exceed AWWA C-502 and are all UL/ULC listed and FM approved. Both types of fire hydrants are designed for high performance, easy repair and minimum end user costs for labor and inventory. Series 27 Series 27 are available in a modern or nostalgic design. All the AVK hydrants offer a numerous features including: Hydrant serviceable under pressure Light-weight, inexpensive hydrant tools available Ductile iron nozzle section, barrel section and base High pressure rating bar (250 PSI) Electrostatically applied polyester coating 360 degree nozzle section rotation possible Removable nozzles secured with external stainless steel allen screw Travel stop nut in the nozzle section for additional safety Pumper nozzle can be changed from 4" - 41/2" Nozzles available in any thread configuration Traffic flange designed for easy repair Stainless steel traffic coupling designed for longer operational life and high corrosion resistance Extensions available in lengths from 6" - 60", bury depths 2' - 13' Patented AVK main valve design -1 piece replaces up to 13 pieces Ductile iron core fully encapsulated with rubber. Completely corrosion resistant (stop pins of stainless steel) 51/4" valve opening for high flow rating 360 degree all bronze drain channel Inlet shoe can be easily changed - available in most configurations (MJ, FL, PO) Series 84/60 The series 84/60 monitor hydrant is particularly made for fire fighting in the chemical and petro-chemical industry, for refineries, tank farms, and airports where large quantities of explosive, flammable liquids are handled and thereby constitute a risk. The hydrant is supplied with two 2 1/2 hose nozzles and one 4 pumper nozzle. The nozzles are supplied with the patented Easy-open system that makes an easy and fast opening of the nozzle possible - even at high pressure. Horizontally the hydrant turns 360º continuously variable, and vertically the monitor can be adjusted from 45º to 70º - also continuously variable. The Monitors HH365 and HH366 are both PN 16. They have a capacity of 2000 respectively 3000 litres/hour and are suitable for both water and foam. The capacity of the spray nozzle is adjustable from 1100 to 3000 litres/hour at 8 bar. Furthermore, the monitor can be supplied with a self-priming foam pipe, and the foam blend can be continuously variable adjusted from 2-6%. Maintenance/repair of the hydrant can be made on location. The well-known ball shut-off principal allows replacement of the inner parts of the hydrant under full pressure without using special tools. In this way, the hydrant does not have to be isolated from the ring main. The spindle rod is made of stainless steel, and the plug is made of polyamide GTW synthetic elastomer.

6 6 Post Indicators Post or wall indicators are mounted end to end with the extension spindel connecting the valve. It is mounted in places where direct access is impossible. It could be gate valves mounted on a water ring main in a factory area, such as oil refineries, chemical plants or airports. The post indicator indicates if the mating valve is in open or closed position. According to government regulations it must be easy for firemen to see if the valve is open or closed, even at a long distance. The post indicator signs OPEN AND SHUT are mounted on the target according to clear locations and according to valve size.

7 7 Post Indicator Valves The post indicator valves are used for underground installation in fire fighting systems. The post indicator flange is incorporated in the top gland giving a compact design. The post indicator indicates the position of the wedge, whether it is open or closed. The basic valve construction is, like valves for water supply, characterized by a fully rubber coated wedge, full and straight bore, low torque operation and O-ring stem seals exchangeable under pressure. The valves are available with flanges, mechanical joints or push-on joint ends in DN (4" - 12"). Picture: MINIMAX GmbH Resilient seated gate valves A published test from City of Roseville, US, has proved that impurities up to Ø 8.7 mm can be handled by a DN 150 mm valve without any problems. The same test has also proved that the unique AVK rubber quality EDK 70 is the only rubber quality which instantly returns to the original shape when the valve is opened again.

8 8 G a t e Va l v e s S e r i e s 0 6 / 3 5 ( D I N ), S e r i e s 2 5 ( A W WA ) a n d S e r i e s 4 5 ( A W WA ) Series 06/35 - The light weight flanged gate valve is very suitable for use in fire fighting systems as an isolating gate valve for maintenance purpose. The pin indicator indicates the wedge position. Micro switches for remote indication of the wedge in open or closed position are available as an optional extra. The basic valve construction is, like valves for water supply, characterized by a fully rubber coated wedge, full and straight bore and 3 independant stem seals. GGG-50 Face to face to DIN 3202, F4 DN VdS-approved Picture: MINIMAX GmbH Series 25 and Series 45 - The OS&Y or NRS gate valves with flanges are used in above ground installations. Due to the rising stem it is easy to recognize the valve position, open or closed, even at a distance. The basic valve design is, like valves for water supply, characterized by a fully rubber coated wedge, full and straight bore, low torque operation and O-ring stem seals exchangeable under pressure. DN (21/2" - 12") UL-listed, FM-approved AVK resilient seated gate valves are designed with a fully vulcanised rubber wedge - internally and externally. With this design no iron parts are exposed to the medium and the excellent rubber vulcanisation prevents creeping corrosion underneath the rubber. The rubber is vulcanized onto the wedge by AVK GUMMI A/S, one of Europe's leading manufacturers of high technology moulded rubber components. The high quality of AVK rubber is characterized by: Smell and taste response characteristics highly suitable for the food industry Very low deformation ensuring optimum sealing High impact resistance preventing corrosion Low friction ensuring low closing torques EPDM rubber for water supply, NBR rubber for gas supply Standard stem sealing system for water applications to DIN standard. NBR wiper ring polyamid bearing with 4 O-rings EPDM rubber manchette Standard stem sealing system for water applications to AWWA standard. NBR wiper ring polyamid bearing with 2 O-rings, exchangeable under pressure with the valve fully opened. O-ring protects the antifriction washers Optional stem material: Low zinc bronze

9 MSPRINKLER-ALAR MSPRINKLER-ALAR 9 Pipework installed above suspended ceiling - pendent sprinklers Sprinkler pipework installed visible - upright sprinklers with riser Sprinkler pipework installed visible - upright sprinklers with riser Pipeworks installed above suspended ceiling - pendent dry sprinklers Escutcheon Wet pipe system for frost-protected rooms Wet pipe valve set Dry pipe valve set Dry pipe system for rooms subject to frost hazard Automatic feed mechanism Test line for pump Water pressure vessel Manifold Town main Overflow drain Control cabinet Suction pipe Town main Pump suction tank Fire pump Compressor unit Jockey pump Feeding tank Picture: MINIMAX GmbH

10 10 H y d r a n t s, G a t e Va l v e s a n d I n d i c a t o r P o s t s f o r F i r e F i g h t i n g Series 27/00 Dry barrel fire hydrant, modern style Bury depth 21/2' - 10' 250 PSI, GGG-50 Inlet options: 4"-6" flanged 4"-6" mechanical joint 6" push-on Series 27/80 Dry barrel fire hydrant, nostalgic style Bury depth 21/2' - 10' 250 PSI, GGG-50 Inlet options: 4"-6" flanged 4"-6" mechanical joint 6" push-on Series 24 Wet barrel fire hydrant 200 PSI GGG-50 UL listed Options: 1 x pumper 2 x hose 1 x pumper 1 x hose Series 25 Flanged gate valve with rising stem 200 PSI DN : GG-25 DN 300: GGG-50 Options: grooved ends or grooved/flanged ends Series 34/00 Post indicator, telescopic for DN P.I. gate valves, bury depth mm GGG-50 Series 45 Gate valve with grooved ends and rising stem GGG-50 Bonnet: GGG-50 Options: flanged ends or grooved/flanged ends Series 34/80 Wall post indicator, DN P.I. gate valves, Stem length mm GGG-50 Series 06/35 Flanged gate valve with position indicator DN PN 10 or 16 GGG-50 VdS approved Series 25 Flanged gate valve for indicator post DN , PN 16 GG-25 Options: push-on ends or mechanical joint ends Series 25 Flanged gate valve for indicator post DN PSI GG-25 Options: push-on ends or mechanical joint ends Series 25 Gate valve with mechanical joint ends for indicator post DN , 200 PSI GG-25 Options: flange ends or IPS push-on ends

11 P o s t I n d i c a t i o r a n d AG ca ct e sva s olr vi e s f o r H y d rf ao nr tfs i ra e n d F i Va g hlt vi ne g s 11 Series 04 Stem caps for gate valves and service connection valves DN GG-25 Series 08 Hand wheel for gate valves DN GG-25 Series 27/70 Extension kit for dry barrel hydrants Series 27/75 Traffic section repair kit for dry barrel hydrants Series 27 Tools for dry barrel hydrants Series 24/82 Break ring repair kit for wet barrel hydrants Series 24/80 Breakable flange unit for wet barrel hydrants Micro Switch for series 06/35 Series 84/60 Dry barrel monitor hydrant According to DIN 3222 Additional ball shut off at inlet Ductile iron, DN 100, PN 16

12 AVK INTERNATIONAL A/S Bizonvej 1, Skovby DK-8464 Galten, Denmark Tel.: Fax: FIREAB

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves 1. General company and product information 2. Flanged gate valves for water 3. Other gate valves for water 4. Combi valves 5. Service connection valves for water 6. Valves and fittings for gas 7. Fire

More information

American- Darling 5¼" B-84-B-5.

American- Darling 5¼ B-84-B-5. -5 Sealed Lubrication Chamber Seals operating threads from water and debris which greatly reduces routine maintenance. Top Travel Stop Nut Helps prevent stem buckling and damage to bronze components which

More information

British Standard Underground Hydrant Range

British Standard Underground Hydrant Range British Standard Underground Hydrant Range 2 THE NEW AVK BRITISH STANDARD HYDRANT RANGE AVK are the renowned market leading innovators, manufacturers and suppliers of BS 750 fire hydrants into the UK,

More information

OPERATION AND MAINTENANCE MANUAL 5-1/4 B-84-B-5 FIRE HYDRANT

OPERATION AND MAINTENANCE MANUAL 5-1/4 B-84-B-5 FIRE HYDRANT OPERATION AND MAINTENANCE MANUAL 5-1/4 B-84-B-5 FIRE HYDRANT INDEX AMERICAN - DARLING 5-1/4 IN. B-84-B-5 FIRE HYDRANT OPERATION AND MAINTENANCE MANUAL OPERATION AND MAINTENANCE REPAIRS Operation and Maintenance...

More information

EWE Ball Valve-Type Tapping Valve. EWE Ball-Type Tapping Valve. EWE GBM Tapping Valves. for water and gas

EWE Ball Valve-Type Tapping Valve. EWE Ball-Type Tapping Valve. EWE GBM Tapping Valves. for water and gas The following overview shows the different EWE tapping valves to help you to make your choice: EWE valve tapping valve for vertical tapping with operating shut-off, for all types of pipe, with external

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information

Fire Hydrant Troubleshooting

Fire Hydrant Troubleshooting Fire Hydrant Troubleshooting Pulsation or chatter during opening and flow of water from hydrant. Loose condition in stem at lower valve plate nut. Tighten lower valve plate nut and secure with SS lock

More information

Sprinkler Guards Model C Model D

Sprinkler Guards Model C Model D Bulletin 208 Rev. M Sprinkler Guards Model C Model D Bulletin 208 Rev. M Model C Sprinkler Guards Model C Series sprinkler guards are designed to be assembled onto installed sprinklers. They are constructed

More information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE

More information

TECHNICAL DATA. 2. LISTINGS AND APPROVALS See Tables 1 & 2.

TECHNICAL DATA. 2. LISTINGS AND APPROVALS See Tables 1 & 2. May 3, 2013 Foam 138a 1. DESCRIPTION Chemguard Water Powered Oscillating Monitors are designed to automatically discharge over a specific design area upon system activation. These are suitable for use

More information

Fire Hydrant Operation and Inspection

Fire Hydrant Operation and Inspection Fire Hydrant Operation and Inspection Fire Hydrant Operation and Inspection What is in this Lesson? 1. Classification of fire hydrants 2. Nomenclature of major hydrant components 3. Operation of compression

More information

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps P/N: DEF-0613A Diesel Exhaust Fluid (DEF) Pumps DEF Solutions Standard Pump has designed a range of unique, preconfigured DEF Pump Packages that are engineered to transfer AdBlue (AUS32) Diesel Exhaust

More information

Buy Karcher Parts Online: www.pressureparts.com. Need Technical Help? Call: 1-800-999-2245 email Requests to: sales@pressureparts.

Buy Karcher Parts Online: www.pressureparts.com. Need Technical Help? Call: 1-800-999-2245 email Requests to: sales@pressureparts. Karcher Model: K 620-M * ( 59556440 ) - Parts Section:1.1 TOP PART Page 1 of 18 1 50346460 1 STRAP 2 63031250 6 SCREW 3 50670230 1 COVER 4 63031940 2 SELF-TAPPING SCREW 5 50309650 1 COVER 6 50635710 1

More information

08.08 Vic-Check Valves

08.08 Vic-Check Valves The check valves are a product of computer-assisted innovative engineering with quality features including a new hydrodynamically efficient profile. The Vic-Check valve utilizes a spring-assisted, single-disc

More information

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features Pressure Relief/Sustaining Valve Prioritizing pressure zones Ensuring controlled pipeline fill-up Preventing pipeline emptying Pump overload & cavitation protection Safeguarding pump minimum flow Excessive

More information

FITTINGS AND VALVES. Ductile Cast Iron Hydrants

FITTINGS AND VALVES. Ductile Cast Iron Hydrants FITTINGS AND VALVES Ductile Cast Iron Hydrants Düker Hydrants Important Elements of a Modern Public Water Supply Ductile cast iron hydrants Düker underground and pillar hydrants Hydrants are an important

More information

RUBBER SLEEVE KNIFE GATE VALVE

RUBBER SLEEVE KNIFE GATE VALVE RUBBER SLEEVE KNIFE GATE VALVE The model knife gate is a wafer valve designed for a wide range of industrial applications. The double-seated design provides bi-directional shut off. The design of the valve

More information

MFP14, MFP14S and MFP14SS Automatic Pumps

MFP14, MFP14S and MFP14SS Automatic Pumps Page 1 of 6 TI-P136-02 ST Issue 12 Cert. No. LRQ 0963008 ISO 9001, S and SS utomatic Pumps Description The Spirax Sarco automatic pump is a displacement receiver operated by steam or compressed air. It

More information

VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)

VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01) VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,

More information

SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS

SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS PART 1: GENERAL 1.01 COORDINATION OF WORK Connection to existing pipelines may require shutdown of AW facilities. Closely coordinate construction work

More information

Vertical selfpriming Side-Channel Pumps Type WPV

Vertical selfpriming Side-Channel Pumps Type WPV Vertical selfpriming Side-Channel Pumps Type WPV FIELD OF APPLICATION The side-channel pumps are selfpriming and operate more economically (better efficiency) than normal centrifugal pumps when handling

More information

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description Style 07 Zero Flex Rigid Coupling The unique angled pad design adjusts to standard pipe tolerances to positively clamp the pipe to resist flexural and torsional loads. Working pressures are based on standard

More information

V47 Series Temperature Actuated Modulating Water Valves

V47 Series Temperature Actuated Modulating Water Valves V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate

More information

API Flanged Safety Relief Valves Series 526 CATALOG

API Flanged Safety Relief Valves Series 526 CATALOG API Flanged Safety Relief Valves Series 26 CATALOG The-Safety-Valve.com 1 Valve finder How to find the right product group High operating to set pressure ratio, high backpressure or low total height? Yes

More information

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description Worldwide Contacts www.tyco-fire.com Model F thru F3 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description The Mulsifyre Nozzles are open (nonautomatic) nozzles and they are designed

More information

61W - Wafer style resilient seated butterfly valve 61L - Lugged style resilient seated butterfly valve

61W - Wafer style resilient seated butterfly valve 61L - Lugged style resilient seated butterfly valve 61W - Wafer style resilient seated butterfly valve 61L - Lugged style resilient seated butterfly valve Features Rounded polished disc edge gives full concentric sealing, lower torques, longer seat life

More information

Materials : Cast iron body

Materials : Cast iron body Size : Ends : Min Temperature : Max Temperature : DN 50 to DN 500 Between flanges ISO PN10-10 C + 90 C Max Pressure : 10 Bars up to DN 200 Specifications : Non rising stem and handwheel Bidirectional tightness

More information

Stainless Steel Single and Dual Circulation Kits

Stainless Steel Single and Dual Circulation Kits Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating

More information

MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS

MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS FIRE DEPARTMENT Bureau of Fire Protection and Life Safety www.cityofsanmateo.org 1900 O Farrell, Suite 140 San Mateo, CA 94403-1332 (650) 522-7940 FAX: (650) 522-7941 TDD: (650) 522-7047 MAINTENANCE AND

More information

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts. www.tyco-fire.com

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts. www.tyco-fire.com Worldwide Contacts www.tyco-fire.com Model EC-HS 80 K-factor, Quick Response Extended Coverage Horizontal Sidewall Sprinklers Installations per VdS CEA 400, Annex E, LH/OH General Description The Model

More information

Flygt Ball Check Valves

Flygt Ball Check Valves 4/13 Supersedes: 6/96 The basic purpose of a check valve is to permit flow in one direction, prevent flow in the opposite direction and perform this function automatically and with minimum maintenance.

More information

Rickmeier Solutions. Gear pumps for superior Lubrication

Rickmeier Solutions. Gear pumps for superior Lubrication Rickmeier Solutions Gear pumps for superior Lubrication P U M P E N T E C H N O L O G I E #1. Introduction Position and significance of Rickmeier products Rickmeier supplies pumps, valves and systems for

More information

VAG Non-Return Valves

VAG Non-Return Valves VAG Non-Return Valves VAG SKR Slanted Seat Tilting Disk Check Valve Body Shaft Disk Bearing bush Seat Technical details Nominal pressure PN 10 / PN 16 Nominal diameter DN 200...1200 Fields of application:

More information

Hydraulic Control Solutions

Hydraulic Control Solutions Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district

More information

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

3, 4, 6 & 8 Model H Series Alarm Check Valve Installation and Maintenance Guide ", ", " & " Model H Series Alarm Check Valve Installation and Maintenance Guide 077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE 99-- 00-2-0 FAX 99--92 www.globesprinkler.com OCTOBER 2 C- BULLETIN A.C.V.I.M.,

More information

Self-operated Temperature Regulators Temperature Regulator Type 1u

Self-operated Temperature Regulators Temperature Regulator Type 1u Self-operated Temperature Regulators Temperature Regulator Type u Application Temperature regulators for cooling installations Control thermostats for set points ) from 0 to 250 C G ½ to G or DN 5 to 50

More information

SunMaxx Solar Filling Station Operating Instructions

SunMaxx Solar Filling Station Operating Instructions SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...

More information

MACHINES RECOVERY SYSTEMS SUPEREVAC CHARGING HOSES VACUUM AND HOSE ADAPTERS, VALVES AND PARTS CHARGING SYSTEMS GAUGES INSTRUMENTS ELECTRONIC

MACHINES RECOVERY SYSTEMS SUPEREVAC CHARGING HOSES VACUUM AND HOSE ADAPTERS, VALVES AND PARTS CHARGING SYSTEMS GAUGES INSTRUMENTS ELECTRONIC RECOVERY SUPEREVAC 29 RECOVERY 1/4" 4-IN-1 BALL VALVE TOOL For vacuum, charge, cores and recovery 18997 18975 18971 18978 18979 Remove and replace Schrader cores without losing charge. Extra 1/4" side

More information

MVX-Series Diesel Engine Air Shut Down Valves

MVX-Series Diesel Engine Air Shut Down Valves MVX-Series Diesel Engine Air Shut Down Valves (Cable operated closure/integral reset lever types) Selection, Application and Maintenance SPECIAL VALVE MVX-304 This is a special version of valve type MVX-303

More information

BROEN UNiFlEx FiTTiNgs FOR BURNiNg gases OEN OEN ifl ifl FOR FOR BURN BURN gas gas

BROEN UNiFlEx FiTTiNgs FOR BURNiNg gases OEN OEN ifl ifl FOR FOR BURN BURN gas gas BROEN UNIFLEX Fittings FOR BURNIN ASES BROEN UniFlex TM Fittings for burning gases BROEN UniFlex TM Fittings for burning gases LAB Table of Contents Content Page Table of Content 2 Product Overview 3 BROEN

More information

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium

More information

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows Application Integrated valves, type RA-N (013G1382) and RA- U (013G1383), with built-in presetting are designed for

More information

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows Application Integrated valves, type RA-N (013G0372) and RA- U (013G0373), with built-in presetting are designed for incorporation

More information

I. Introduction. 10 minutes

I. Introduction. 10 minutes I. Introduction 10 minutes Introduction (1 of 2) An uninterrupted water supply is: The primary weapon for extinguishment Essential for fire fighter safety Ensuring a dependable water supply is a critical

More information

SELECTION, APPLICATION AND MAINTENANCE

SELECTION, APPLICATION AND MAINTENANCE DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine

More information

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value Ball valve C valve ball completely moulded in place, extremely low clearance volume, high k v value Advantage maximum safety due to valve ball completely moulded in place - ball and ball seat cannot be

More information

2013 Edition. Flanged fittings 30"-64" NSF. industrial Applications, water & Wastewater. Certified to ANSI/NSF 61

2013 Edition. Flanged fittings 30-64 NSF. industrial Applications, water & Wastewater. Certified to ANSI/NSF 61 30"-64" Ductile Iron industrial Applications, water & Wastewater 2 Table of Contents Flanged Fittings for Water 3 Flange Details 5 Flanged Fittings 6 90º and 45º Bend 6 22-1/2º and 11-1/4º Bends 7 Tees

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES EFFECTIVE: OCTOBER 2007

TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES EFFECTIVE: OCTOBER 2007 TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES 301.010 ANNUAL SERVICE TEST FOR FIRE HOSE EFFECTIVE: OCTOBER 2007 The Department will test all fire hose annually. The testing of fire hose determines its serviceability.

More information

ESFR DRY PENDENT SPRINKLER VK502 (K14.0) TECHNICAL DATA

ESFR DRY PENDENT SPRINKLER VK502 (K14.0) TECHNICAL DATA December 19, 2013 Sprinkler 122j 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Dry Pendent Sprinkler VK502 is a fast response fusible element type sprinkler designed for use in storage areas

More information

AIR LINE VALVES AND GAUGES

AIR LINE VALVES AND GAUGES AIR LINE VALVES AND GAUGES INGERSOLL-RAND AIR LINE VALVES AND GAUGES Maintaining consistent air pressure throughout the entire system is crucial for maximum performance and productivity. Ingersoll-Rand

More information

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to8. 150 PSI : 10 to 24

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to8. 150 PSI : 10 to 24 Type series booklet 8448.1/2-EN--US ISORIA Centered disc butterfly valves with AMRING elastomer liner 240 PSI: 1½ to8 150 PSI : 10 to 24 Design in accordance with ISO 10631 Manual, electrical, pneumatical

More information

10 2161.002201 2161.002401 slide flange. 11 2161.001295 2161.001296 slide ring

10 2161.002201 2161.002401 slide flange. 11 2161.001295 2161.001296 slide ring spareparts list sparepart part No. code No. GP 40 GP 50 shaft seal 10 2161.002201 2161.002401 slide flange 11 2161.001295 2161.001296 slide ring 12 2161.001226 2161.001265 O-ring 13 5642.ABBR01 5642.ABCD01

More information

BUTTERFLY VALVES. An industry leader in underground and in-plant applications. STYLE 4500 3 24 STYLE 1450 30 54. Consult factory for sizes 60 120

BUTTERFLY VALVES. An industry leader in underground and in-plant applications. STYLE 4500 3 24 STYLE 1450 30 54. Consult factory for sizes 60 120 An industry leader in underground and in-plant applications. BUTTERFLY VALVES STYLE 4500 3 24 STYLE 1450 30 54 Consult factory for sizes 60 120 C504 Class 150B & 250B M&H Valve is a division of McWane,

More information

FILTRATION AMIAD PLASTIC FILTERS, SCREENS & DISCS

FILTRATION AMIAD PLASTIC FILTERS, SCREENS & DISCS 4 AMIAD PLASTIC FILTERS, SCREENS & DISCS Max pressure 10.0 Bar, max temperature 60 O 3/4 to 1 1/2 bodies manufactured from polyacetal 2 bodies and above manufactured from polymade and glass fibre 3/4 to

More information

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES GATE VALVE O.S. & Y 1.0 Periodic Inspections 1.1 The valve stem packing should be inspected at least monthly. If the stem packing shows signs of leakage, simply tighten the adjusting nuts to compress the

More information

Model 1210C Battery Powered Pump Shown. Description

Model 1210C Battery Powered Pump Shown. Description 12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with

More information

MONITOR SECTION INDEX

MONITOR SECTION INDEX MONITOR SECTION INDEX Daspit Tool... E2 Daspit Tool - Truck Mount... E3 Daspit Tool - Throw Down Model... E4 Alpha MA-HV4-4 Aluminum Tiller Bar Monitor... E5 Alpha-E Tiller Bar Montior - 3... E6 SharpShooter

More information

BUTTERFLY VALVES. An industry leader in underground and in-plant applications. STYLE 4500 3 24 STYLE 1450 30 54. Consult factory for sizes 60 120

BUTTERFLY VALVES. An industry leader in underground and in-plant applications. STYLE 4500 3 24 STYLE 1450 30 54. Consult factory for sizes 60 120 An industry leader in underground and in-plant applications. BUTTERFLY VALVES STYLE 4500 3 24 STYLE 1450 30 54 Consult factory for sizes 60 120 C504 Class 150B & 250B M&H Valve is a division of McWane,

More information

SECTION 15105 DUCTILE IRON PIPE AND FITTINGS

SECTION 15105 DUCTILE IRON PIPE AND FITTINGS SECTION 15105 DUCTILE IRON PIPE AND FITTINGS PART 1 GENERAL.01 COORDINATION OF WORK Connection to existing pipelines may require shutdown of Owner facilities. Closely coordinate construction work and connections

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

Compact pumps from the wastewater experts. FLYGT 3045, 3057, 3068. Power range 0.75 2.4 kw.

Compact pumps from the wastewater experts. FLYGT 3045, 3057, 3068. Power range 0.75 2.4 kw. Compact pumps from the wastewater experts FLYGT 304, 307, 3068. Power range 0.7.4 kw. Wastewater is unpredictable, Flygt pumps are not If you want a wastewater pump that just works month after month, year

More information

Direct steam injection humidifiers

Direct steam injection humidifiers Direct steam injection humidifiers Direct steam injection gives quality control of air humidity. Research and development in separation, the use of lightweight stainless steel combined a constant temperature

More information

www.klmtechgroup.com TABLE OF CONTENT

www.klmtechgroup.com TABLE OF CONTENT Page : 1 of 36 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 3 REFERENCES

More information

Air Eliminators and Combination Air Eliminators Strainers

Air Eliminators and Combination Air Eliminators Strainers Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.

More information

Series MJC Multiple Jet Controls DN20, DN25, DN40, and DN50, 12 bar BSPT Inlet & Outlets Threads General Description.

Series MJC Multiple Jet Controls DN20, DN25, DN40, and DN50, 12 bar BSPT Inlet & Outlets Threads General Description. Worldwide Contacts www.tyco-fire.com Series Multiple Jet Controls DN20, DN25, DN40, and DN50, 2 bar BSPT Inlet & Outlets Threads General Description The TYCO Series Multiple Jet Controls are control valves

More information

lifting stations motralec

lifting stations motralec 3.0 lifting stations motralec 4 rue Lavoisier. ZA Lavoisier. 95223 HERBLAY CEDEX Tel. : 01.39.97.65.10 / Fax. : 01.39.97.68.48 Demande de prix / e-mail : service-commercial@motralec.com www.motralec.com

More information

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES SECTION 15062 STEAM AND CONDENSATE PIPING PART 1 DESIGN DIRECTIVES 1.1 QUALITY ASSURANCE A. Comply with the provisions of the following: 1.2 DESIGN CRITERIA 1. ASME B 31.9 Building Services Piping : for

More information

HOPPER SHAPE KNIFE GATE VALVE

HOPPER SHAPE KNIFE GATE VALVE HOPPER SHAPE KNIFE GATE VALVE The model knife gate is a uni-directional wafer valve designed for industrial bulk handling service applications (powdered and granular products). The special design of the

More information

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business

More information

SPERRYN GAS CONTROLS DELTA FLUID PRODUCTS LIMITED

SPERRYN GAS CONTROLS DELTA FLUID PRODUCTS LIMITED SPERRYN GAS CONTROLS DELTA FLUID PRODUCTS LIMITED Domestic and Non-Domestic Meter Regulators G940/G941 - Domestic Meter Regulator Domestic regulator offering high performance in a compact unit. Sizes:

More information

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features Booster Pump Control Valve Quick Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery of variable

More information

SIMPLAIR PIPING. www.irtools.com 1-800-376-TOOL

SIMPLAIR PIPING. www.irtools.com 1-800-376-TOOL SIMPLAIR PIPING INGERSOLL-RAND SIMPLAIR PIPING With push-in fittings and lightweight anodized aluminum pipe, a SimplAir system provides ideal connection throughout your entire air distribution system.

More information

NFPA31FuelOilPiping 1 Revised 3-1-11

NFPA31FuelOilPiping 1 Revised 3-1-11 NFPA 31 Fuel Oil Piping, Installation and Testing Chapter 8 Fuel Piping Systems and Components 8.1 Scope. This chapter shall apply to piping systems and their components used to transfer fuel oil from

More information

QLM and QLD Series Three-port Control Valves

QLM and QLD Series Three-port Control Valves Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

System Accessories Pricing. Page 0 Effective 7/02

System Accessories Pricing. Page 0 Effective 7/02 System Accessories Pricing Page 0 Effective 7/02 Firetrace Tubing 200005 Firetrace Detection Tubing (FDT) (Per Foot) (Available in continuous lengths up to 333 ft.) Accessories 400001 400004 400061 400060

More information

SISTO-16TWA/HWA/DLU. Type Series Booklet

SISTO-16TWA/HWA/DLU. Type Series Booklet Diaphragm Valve SISTO-16TWA/HWA/DLU PN16 DN 15-200 Maintenance-free Flanged Ends Type Series Booklet Legal information/copyright Type Series Booklet SISTO-16TWA/HWA/DLU All rights reserved. The contents

More information

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT INTRODUCTION No matter how reliable fire protection equipment may seem, periodic maintenance is needed to ensure proper operation. Fire protection

More information

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23 Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23 Application Pressure regulators for set points from 5 mbar to 28 bar Valves in nominal sizes DN 15 to 100 Nominal pressures

More information

Installation Instructions 4508 4508S

Installation Instructions 4508 4508S SYMPHONY Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect

More information

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200) Features 1. Differential latching clapper-type, lightweight, dependable construction. 2. Low Air Pressurized System, psi -to- 2 psi (0.6 bar -to- 1.9 bar) Max 3. Reset externally. Cover removal is not

More information

FIVE YEAR CERTIFICATION REPORT

FIVE YEAR CERTIFICATION REPORT GARDEN GROVE FIRE DEPARTMENT FIRE PREVENTION DIVISION FIVE YEAR CERTIFICATION REPORT Service and maintenance report of automatic fire extinguishing systems, including fire sprinklers, dry, deluge, and

More information

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents English translation of German original Technical Information TI-P11 SITEMA PowerStroke Mould Closing Devices series FS drive system for powerful forces on a short stroke hydraulic actuation closing force

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...

More information

MÁQUINAS AGRÍCOLAS JACTO S.A. EDITION

MÁQUINAS AGRÍCOLAS JACTO S.A. EDITION AJ English version EDITION - 06/007 CODE - 9790 Parts catalog MÁQUINAS AGRÍCOLAS JACTO S.A. Rua Dr. Luiz Miranda, 650 7580-000 - Pompéia - SP - Brasil Tel.: +55 4 3405-00 - Fax: +55 4 345 306 E-mail: export@jacto.com.br

More information

Model F1FR Series Quick Response Glass Bulb Sprinklers

Model F1FR Series Quick Response Glass Bulb Sprinklers Model F1FR56 Sprinkler Types Standard Spray Standard Spray Conventional / Vertical Sidewall Model F1FR56 Recessed Sprinkler Types Standard Spray Model F1FR56 Concealed Sprinkler Types Standard Spray Model

More information

Automatic Fire Fighting Monitors

Automatic Fire Fighting Monitors Automatic Fire Fighting Monitors Fire Protection Solutions Automatic Fire Fighting Monitors Foreword Automatic monitors are devices used to deliver large amounts of water or water/foam solution to remote

More information

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and

More information

Nozzle Check Valves. NOREVA nozzle check valves are used

Nozzle Check Valves. NOREVA nozzle check valves are used Nozzle Check Valves NOREVA nozzle check valves are used in applications where the reverse flow of a fluid has to be avoided. These valves are suitable for all kind of liquid and gaseous fluids and fire

More information

Pressure regulating valve with modulating kit, type DRV

Pressure regulating valve with modulating kit, type DRV Operation Installation and Maintenance Instructions Pressure regulating valve with modulating kit, type DRV hp-technik GmbH Industriepumpen-Förderaggregate und Anlagenbau Gablonzer Straße 21 D-76185 Karlsruhe

More information

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html

More information

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR MAIN FEATURES The pneumatic S GATE knife gate valve is intended for the automatic shut off of pipes of the heavy fluids like slurries and powders. The main fields of application are the water treatment,

More information

kymanual or Automatic - it s your Choice

kymanual or Automatic - it s your Choice . kymanual or Automatic - it s your Choice ky LKB Automatic or Manual Butterfly Valve Application LKB is a sanitary automatically or manually operated butterfly valve for use in stainless steel pipe systems.

More information

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description Product Manual CVS Type 67AFR Filter Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS Type 67AFR

More information

1-1/2 Inch (DN40) 9 lbs. (4,1 Kg) 8 lbs. (3,6 Kg) Flange Groove* N/A N/A. Flange Flange N/A N/A

1-1/2 Inch (DN40) 9 lbs. (4,1 Kg) 8 lbs. (3,6 Kg) Flange Groove* N/A N/A. Flange Flange N/A N/A Worldwide Contacts www.tyco-fire.com DV-5 Deluge Valve Diaphragm Style General Description The TYCO 1-1/2 thru inch (DN40 thru DN200), DV-5 Deluge Valves are diaphragm type valves designed for vertical

More information

APCO SLOW CLOSING AIR/VACUUM VALVES

APCO SLOW CLOSING AIR/VACUUM VALVES BULLETIN 1 JULY 01 APCO SLOW CLOSING AIR/VACUUM VALVES Series 1900 APCO Slow Closing Air/Vacuum s Maximum Air Flow Velocity in Good Pipeline Design The Air/Vacuum operates in the normal fashion allowing

More information

DeZURIK 3" (75MM) & LARGER ECCENTRIC PLUG VALVES

DeZURIK 3 (75MM) & LARGER ECCENTRIC PLUG VALVES BULLETIN 12.00-1C SUPERSEDES 12.00-1C & 12.60-1A JUNE 2014 DeZURIK 3" (75MM) & LARGER ECCENTRIC PLUG VALVES www.dezurik.com The DeZURIK Eccentric Plug Valve In thousands of installations worldwide, DeZURIK

More information

G. VULCANIZED SEAT Pressure sensitive seating with full disc overlap provides positive seating at high and low pressures.

G. VULCANIZED SEAT Pressure sensitive seating with full disc overlap provides positive seating at high and low pressures. A B C D G F E J H I A. RETAINER PLUGS Retain hinge and stop pins while providing compression to stabilization spheres. B. STABILIZATION SPHERES Stabilize hinge and stop pins, preventing vibration and wear.

More information

Conlift1, Conlift2, Conlift2 ph+

Conlift1, Conlift2, Conlift2 ph+ GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications

More information