Presentation at the 3 rd SAFOODNET seminar
|
|
- Sheryl Chambers
- 7 years ago
- Views:
Transcription
1 HYGIENE SURVEY IN ROMANIAN BAKERIES ALINA DOBRE, IBA, ROMANIA & SATU SALO, VTT, FINLAND INTRODUCTION Hygiene survey was performed in six Romanian bakeries. The work was carried out at VTT Technical Research Centre of Finland (Espoo, Finland) and IBA (Institutul de Bioresurse Alimentare, Bucharest, Romania) from October 2008 to February The main aim of the work was to detect microbial contaminants from bakery environment and process line and evaluate hygiene state in Romanian bakeries. 1 (9)
2 SAMPLING IN BAKERIES Surface samples from process environment, equipment, packaging material and protective clothing of workers: the amount of aerobic bacteria, yeasts and moulds, Enterobacteriaceae, coliforms and Escherichia coli. Swab samples taken from process environment: the presence of Listeria spp., L. monocytogenes and Salmonella spp. Water samples: the amount of aerobic bacteria, yeasts and moulds, Enterobacteriaceae, coliforms, E. coli, Bacillus cereus and bacterial spores Air samples: the amount of aerobic bacteria, yeasts and moulds Raw material and product samples: the amount of aerobic bacteria, yeasts and moulds, Enterobacteriaceae, coliforms, E. coli, B. cereus and bacterial spores and presence of Listeria spp., Listeria monocytogenes and Salmonella spp. SAMPLING TOOLS The surface and workers samples were taken aseptically using four various Petrifilms total aerobic bacteria, yeast and moulds, Enterobacteriaceae, coliforms and Escherichia coli. Petrifilm 3M TM Enterobacteriaceae Count Plate Petrifilm 3M TM E.coli Count Plate Petrifilm 3M TM Yeast and Mould Count Plate Petrifilm 3M TM Aerobic Count Plate 37 0 for 48 h 25 0 for 120 h 25 0 for 72 h Method: The premoistened Petrifilms were pressed against surfaces at each sampling point. 2 (9)
3 SAMPLING TOOLS Air sampling was performed with MAS 100 air sampler. Air samples (100 l and 250 l) were collected directly on agar plates for aerobic bacteria and yeast and mould counts. The plates for aerobic bacteria were incubated at 25 C for 72 h and the plates for yeast and mould counts at 25 C for 120 h. MAS 100 air sampler SAMPLING TOOLS Water samples were taken from sources that are important for the production process but also for the hygiene program. Method of analysis: by filtering 100 ml of water samples through filters (450 m pore size). filters were placed aseptically on 4 various agar plates depending on the microbiological indicator tested: Aerobic bacteria plate count agar plates 25 0 C for 72 h Yeast & Mould potato dextrose agar 25 0 C for 120 h Bacterial spores plate count agar 30 0 C for 72 h Bacillus cereus chromogenic Bacillus cereus agar 30 0 C for 48 h In addition water samples were analysed on Petrifilms using 1 ml of water For bacterial spores the water samples were subjected to heat treatment at 80 0 C for 20 min; filtered and cultured on Plate Count Agar and Aerobic Count Petrifilm and incubated at 30 0 C for 72 h. 3 (9)
4 Properly cleaned surfaces should not contain coliforms and the amount of total aerobic bacteria should also be below 100 colony forming units (cfu) / 20 cm². The presence of coliforms indicate poor hygiene. The surfaces that are not in direct contact with food must also be cleaned in order to avoid cross contamination. Microbiological water quality is influenced by the hygienic status of hoses and taps, so is an important point of control for the hygienic program. For maintaining air quality is important to separate areas and distribution of air flow from high hygiene areas to lower hygiene areas. based on experience obtained in hygiene surveys performed at VTT and recommendations found in literature Surface samples Quality limits EC Ecoli E. coli 20 cm 2 ECcoliforms Coliforms 20 cm 2 EB Enterobacteriaceae 20 cm 2 AC Aerobic bacteria 20 cm 2 YM ** Yeasts 30 cm 2 YM** Moulds 30 cm 2 Good quality Coliforms & Enterobacteriaceae in raw cereal grains and flours do not imply mishandling < 1 < 1 < Adequate / not recommended 20 > > > 30 Poor > 1 > 1 > 1 > 100 > 30 > 30 ** sum of yeasts and moulds together needs to fit the category 4 (9)
5 based on experience obtained in hygiene surveys performed at VTT and recommendations found in literature EC Ecoli EC coliforms EB AC YM yeast YM moulds Workers Quality limits E. coli Coliforms Enterobacteriaceae Aerobic bacteria Yeasts Moulds 20 cm 2 20 cm 2 20 cm 2 20 cm 2 30 cm 2 30 cm 2 Good quality < 1 < 1 < Adequate / not recommended 20 > > 30 1 > 30 Poor > 1 > 1 > 1 > 100 > 30 > 30 based on experience obtained in hygiene surveys performed at VTT and recommendations found in literature EC Ecoli ECcoliforms EB AC YM YM AC Liquid (1 ml on Petrifilm) E. coli Coliforms Enterobacteriac Aerobic Bacterial Yeasts Moulds Quality limits eae bacteria spores ml ml ml ml ml ml ml Good quality < 1 < 1 < 1 < 100 < 100 < 100 < 100 Adequate Poor PCA CBcA PCA PDA PDA Liquid (100 ml on filter) Aerobic bacteria B. cereus Bacterial spores Yeasts Moulds Quality limits 100 ml 100 ml 100 ml 100 ml 100 ml Good quality < < < < < Adequate Poor (9)
6 based on experience obtained in hygiene surveys performed at VTT and recommendations found in literature AIR PCA PCA PDA PDA PDA PDA Aerobic bacteria Aerobic bacteria Yeasts Moulds Yeasts Moulds Quality limits 100 litre 250 litre 100 litre 100 litre 250 l 250 l Good quality < 10 < 25 < 3 < 2 < 6 < 5 Adequate / not recommended Poor > 30 > 75 > 8 > 20 Swabs Listeria Salmonella Quality limits pos/neg pos/neg Good quality neg neg Poor pos pos SURFACE SAMPLES RESULTS IN PERCENTAGES 164 surfaces were studied in bakeries, including environmental, non and food contact equipment samples. From all sampling points the amounts of aerobic bacteria, yeasts and moulds, Enterobacteriaceae, coliforms and Escherichia coli were studied EC Ecoli EC coliforms* EB* AC YM yeast YM moulds E. coli Coliforms Enterobacteriaceae Aerobic bacteria Yeasts Moulds 20 cm 2 20 cm 2 20 cm 2 20 cm 2 30 cm 2 30 cm 2 Good quality Adequate Poor * coliforms and Enterobacteriaceae in raw cereal grains and flours do not imply mishandling 6 (9)
7 CONCLUSIONS VISUAL OBSERVATIONS In general 5 bakery factories were visually in good condition and one in adequate condition (mainly because of improper condition of walls, floors and ceilings). In all bakeries no unnecessary utensils were in the process area and the personnel was wearing protective clothing according to instructions. Compared to Finnish bakeries there was a lot of personnel in the factories. Personnel is one of the main contamination sources. More attention should be paid to the working routines and hygiene of the protective clothing. CONCLUSIONS WATER In five bakeries the amount of microbes in water varied in different sampling places and in one bakery all the water samples analysed were of good quality. Damaged, dirty hoses and taps can contaminate the water taken from the main water pipeline. The water posts available in the factory must all be in regular use to avoid accumulation of biofilms in the pipelines and hoses. Damaged gaskets, hoses etc. parts that wear must be maintained. 7 (9)
8 CONCLUSIONS AIR The quality of air was in three bakeries at same level in all parts of factory and the microbe level was similar with outdoor air. In three bakeries the air quality was better in packaging area than in other parts. In one bakery the total bacterial count of air inside the factory was smaller than in the outdoor air indicating that the doors and windows were kept closed as they should. The other five bakeries were told that the airborne contamination risks can be reduced by keeping windows closed, by installing air filters, by separating areas and by arranging the air to flow from the high hygiene areas to the lower hygiene areas. CONCLUSIONS PATHOGENES In all of these six hygiene surveys neither Salmonella spp. nor Listeria monocytogenes were found. However Listeria innocua was found in one sample. Raw materials and product samples were generally of good quality 8 (9)
9 ACKNOWLEDGEMENT Special thanks to: Dr. Gun Wirtanen (VTT) Dr. Nastasia Belc (IBA, Institutul de Bioresurse Alimentare ) Dr. Gabriela Nedita (IBA) Dr. Valeria Gagiu (IBA) Cooperation bakeries in Romania SAFOODNET project (FP ) 9 (9)
CERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION In terms of section 22(2) (b) of the Accreditation for Conformity Assessment, Calibration and Good Laboratory Practice Act, 2006 (Act 19 of 2006), read with sections 23(1),
More informationZoning requirements for Dairy Suppliers
Zoning requirements for Dairy Suppliers Overview What is zoning? Zoning requirements? Why do we need zoning? How Does MDLZ International Define The Different Levels of Zoning? Equipment examples for each
More information3M Food Safety. Quality Solutions. for. Testing Times
3M Food Safety Quality Solutions for Testing Times 3 The Importance of Food Quality Producing safe and healthy food is critical to the success of one of the largest industries worldwide. New ingredients,
More information3M Food Safety. Innovative Solutions. that Enable Food Safety. ProcessingSafety
3M Food Safety Innovative Solutions that Enable Food Safety ProcessingSafety Innovative Solutions that Enable Food Safety The importance of food safety Producing safe and healthy food is critical to the
More informationEnvironmental Monitoring of Clean Rooms
Environmental Monitoring of Raul Duarte President DDK Scientific, Corp. Copyright DDK Scientific, Corp. 2008, 2009, DDK Scientific, Corp. Proprietary A manufacturing facility for pharmaceutical products
More informationEnvironmental Monitoring
Environmental Monitoring Purpose of Environmental Monitoring Critical process within the pharmaceutical and biotechnology industries. Determines the microbial and particulate content of cleanroom air and
More informationPresentation at the 3 rd SAFOODNET seminar
Sense and nonsense in standardisation Dr Rijkelt Beumer Laboratory of Food Microbiology Wageningen University (NL) Standardisation is a process in which on national, European or mondial level agreements
More informationCHALLENGES AND FUTURE FORECASTS OF MEASUREMENT TECHNOLOGIES IN WATER MICROBIOLOGY
CHALLENGES AND FUTURE FORECASTS OF MEASUREMENT TECHNOLOGIES IN WATER MICROBIOLOGY Dr. Elias Hakalehto Adjunct Professor, University of Eastern Finland R&D Director, Samplion Ltd. AREAS OF WATER MICROBIOLOGY
More informationEnvironmental Monitoring
Chapter 10 Environmental Monitoring By the end of this chapter, you will be able to: l List the types of environmental testing l Name three types of checks that are carried out to ensure the isolator is
More informationSTUDIES ON THE AIR QUALITY IN A DAIRY PROCESSING PLANT
STUDIES ON THE AIR QUALITY IN A DAIRY PROCESSING PLANT K. Radha* and Lakshmi S. Nath Department of Dairy science, College of Veterinary and Animal sciences, Mannuthy, Kerala - 680651 Received : 27.05.2014
More informationThis project is financed by the EUROPEAN UNION. HACCP Case study Feta cheese
HACCP Case study Feta cheese 1. Introduction A family-owned medium-sized cheese making plant has been asked by local retail customers to provide a HACCP Plan for its main product, Feta cheese. 2. Terms
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK
21-47 High treet, Feltham, Middlesex, TW13 4UN, UK ublic Health England, Food, Water and Environmental Microbiology Laboratory, orton orton Down alisbury Wiltshire 4 0JG Contact: Dr C Willis Tel: +44 (0)1980
More informationNational Food Safety Standard Food microbiological examination: Aerobic plate count
National Food Safety Standard of the People s Republic of China GB4789.2-2010 National Food Safety Standard Food microbiological examination: Aerobic plate count Issued by 2010-03-26 Implemented by 2010-06-01
More informationMicrobial Air Quality in a 50-year-old Middle School
Microbial Air Quality in a 50-year-old Middle School Benjamin Borgo and Mina Mostafavi * Biology Department, Skyline College, San Bruno CA August 2007 Accepted for publication Society for the Advancement
More informationMicrobiological Guidelines for Ready-to-eat Food
Microbiological Guidelines for Ready-to-eat Food May 007 (revised) Centre for Food Safety This set of Guidelines is published by The Centre for Food Safety, Food and Environmental Hygiene Department. The
More informationTools for risk assessment in the food industry. Research Scientists Satu Salo & Kaarina Aarnisalo, VTT
Tools for risk assessment in the food industry Research Scientists Satu Salo & Kaarina Aarnisalo, VTT Food industry, safety and hygiene management project (TRA) 2000 04 Partners in co operation: VTT (co
More informationPrinciples of Microbiological Testing: Methodological Concepts, Classes and Considerations
Principles of Microbiological Testing: Methodological Concepts, Classes and Considerations Russell S. Flowers Silliker Group Corp. Relating Microbiological Testing and Microbiological Criteria to Public
More informationMarine Microbiological Analysis of Ballast Water Samples
MICROBI MARIS BIOTEC Prof. Dr. Johannes F. Imhoff (CEO MicrobiMaris Biotec) Report on the validation of a method for the determination of bacteria (Escherichia coli, Enterococci and Vibrio cholerae) in
More informationDAIRYNET HYGIENE CONTROL IN NORDIC DAIRIES
ESPOO 2004 VTT PUBLICATIONS 545 DAIRYNET HYGIENE CONTROL IN NORDIC DAIRIES PUBLICATIONS 545 DAIRYNET HYGIENE CONTROL IN NORDIC DAIRIES Gun Wirtanen & Satu Salo (eds.) VTT Biotechnology ISBN 951 38 6408
More informationPredictive microbiological models
Campden BRI food and drink innovation Predictive microbiological models What are they and how can they be used in the food industry? PREDICTIVE MICROBIOLOGICAL MODELS: WHAT ARE THEY AND HOW CAN THEY BE
More informationChallenges in the Food Industry. Nuno Reis Workshop on Microbial Safety in Food Industry Using Rapid Methods 1
Challenges in the Food Industry Nuno Reis Workshop on Microbial Safety in Food Industry Using Rapid Methods 1 Presentation Overview Traditional Microbiology Rapid Microbiology? Quality Indicators Pathogen
More informationAFDO 2010, Norfolk, VA James Marsden Regents Distinguished Professor Jasdeep Saini Kansas State University
Strategies for Control of Listeria monocytogenes AFDO 2010, Norfolk, VA James Marsden Regents Distinguished Professor Jasdeep Saini Kansas State University Listeria monocytogenes Small Gram + rod, facultative
More informationA Guide to Monitoring. Surface Hygiene
A Guide to Monitoring Surface Hygiene A guide for kitchens supermarkets food industry food education health inspectors Contents Page I History and Theory Marjatta Rahkio 1 1 History of hygiene sampling
More informationCLEAN ROOM MONITORING REGULATORY STANDARDS
CLEAN ROOM MONITORING REGULATORY STANDARDS Air Classification as per Schedule M Maximum permitted number of particles / m3 equal or above at rest in operation 0.5µm 5.0µm 0.5µm 5.0µm A 3,520 29 3,500 29
More informationEvaluation of Microbial Growth and Survival on Construction materials treated with Anabec NewBuild 30
Evaluation of Microbial Growth and Survival on Construction materials treated with Anabec NewBuild 30 Absar Alum, Ph.D. Department of Civil and Environmental Engineering Arizona State University Tempe,
More informationNational Food Safety standard of the People s Republic of China
National Food Safety standard of the People s Republic of China GB 23790 2010 National food safety standard Good manufacturing practice for powdered formulae for infants and young children Issued date:
More informationBACTERIA COUNTS IN RAW MILK
BACTERIA COUNTS IN RAW MILK Richard L. Wallace TAKE HOME MESSAGES Bacterial contamination of raw milk can generally occur from three main sources; within the udder, outside the udder, and from the surface
More informationA comparison of Bremnes Systems Petrifilm scanner, 3M s Petrifilm reader and manual counting for Petrifilm AC films
Norsk Matanalyse (The Norwegian Institute for Food and Environmental Analysis) A comparison of Bremnes Systems Petrifilm scanner, 3M s Petrifilm reader and manual counting for Petrifilm AC films Proof
More informationAssessment of the Potential for Cross-contamination of Food Products by Reusable Shopping Bags
ARTICLES Food Protection Trends, Vol. 31, No. 8, Pages 508 513 Copyright 2011, International Association for Food Protection 6200 Aurora Ave., Suite 200W, Des Moines, IA 50322-2864 Assessment of the Potential
More informationMicrobiological Analysis
Microbiological Microbiological 117 Gridded Membrane Filters from Cellulose Nitrate (Cellulose Ester) acc. to ISO Norms, Sterile and Individually Packed, for Colony Counts Membrane Filters Microbiological
More informationENVIRONMENTAL MONITORING
ENVIRONMENTAL MONITORING Assessment and verification of the adequacy of the aseptic compounding environment is essential. Environmental monitoring programs are designed to promptly identify potential sources
More informationEnumerating Chromogenic Agar Plates Using the Color QCOUNT Automated Colony Counter
P3-4 IAFP, 06 Enumerating Chromogenic Agar Plates Using the Color QCOUNT Automated Colony Counter EILEEN GARRY, GRACE OUATTARA, PATRICK WILLIAMS, AND MEREDITH PESTA SPIRAL BIOTECH, INC., NORWOOD, MA Two
More informationCleaning and Disinfection Agenda. 1. Cleanroom Classification. Cleanroom Classification. What does contamination mean? Types of contamination
Cleaning and Disinfection Agenda CLEANING AND DISINFECTION TECHNIQUES Barbara Wessels Key Account Manager Ecolab Contamination Control October 2014 1. Cleanroom classification and definition 2. Sources
More informationLevel 4 Award in Food Safety Management for Manufacturing
Level 4 Award in Food Safety Management for Manufacturing December 2008 This qualification has a Credit Value of 6 Description This qualification covers all of the necessary aspects of food hygiene and
More informationThe original inspection report is reproduced below with brief notes showing what was found at the time of the re-rating visit <in blue>.
National Food Hygiene Rating Scheme Re-rating Premises: Adults with disabilities Daycare at the Hamlet Centre Original Inspection Date: 16.01.2012 Request Date: 31.05.2012 Re-rating Visit Date: 13.09.2012
More informationEnvironmental Monitoring in Isolators and Clean Rooms ICR settle and contact plates ICRplus contact plates
Environmental Monitoring in Isolators and Clean Rooms ICR settle and contact plates ICRplus contact plates is a division of Merck KGaA, Darmstadt, Germany Culture media designed with safety in mind Monitoring
More informationBacterial Assessment of Applied Treated Effluent from Wastewater Systems
Bacterial Assessment of Applied Treated Effluent from Wastewater Systems Kasie Stambaugh Bachelor of Science in Agriculture Science and Natural Resources Oklahoma State University (OSU) December 2011 Masters
More informationTransferring a Broth Culture to Fresh Broth
Sterile Technique It is very important in microbiology to work with pure cultures. Unfortunately this is difficult. The world around us is covered with microorganisms. Microorganisms are even carried on
More informationFood safety risk management in bakeries
Food safety risk management in bakeries Helen Ehavald Fazer Bakeries Estonia Introduction o Wide variety of bakery products are produced: wheat loafs, rye breads, buns, coffee breads, cakes, cookies, pizzas,
More informationSession 1 Fundamentals of Microbiology
Session 1 Fundamentals of Microbiology Session overview Classification Microbial nomenclature Microbial growth Microbial death Spore formation Classification The Five Kingdom system is used to classify
More informationCleaning. By the end of this chapter, you will be able to: Introduction. Definitions. Chapter 9
Chapter 9 By the end of this chapter, you will be able to: l Define the terms cleaning, decontamination, disinfection l List the factors that affect disinfection l Describe the aims of a cleaning schedule
More informationRisk management in catering
Risk management in catering Dr.sc.ing. Aija Melngaile Latvia University of Agriculture 5 May, 2009 1 Background of the topic Consumer demand and right for high quality and safe food EU food policy & regulations
More informationTesting Waste Water for Fecal Coliforms and/or E.coli using Colilert and Colilert -18 & Quanti-Tray
Testing Waste Water for Fecal Coliforms and/or E.coli using Colilert and Colilert -18 & Quanti-Tray Gil Dichter World Wide Technical Support Manager, Water www.idexx.com/water 1 FOR ALL OF YOU WHO ARE
More informationIntroduction. Contamination sources
Introduction Tim Sandle www.pharmamicro.com Cleanrooms and environmental monitoring Contamination sources Contamination control The human microbiome and the microbial ecology of people Case study: Microorganisms
More informationResult: COMPLETE Report Date: 08-OCT-2012
Send To: 1X220 Ms. Laura Marshall AcornVac, Inc. 13818 Oaks Avenue Chino CA 91710 United States Facility: 1X221 AcornVac, Inc. 13818 Oaks Avenue Chino CA 91710 United States Result: COMPLETE Report Date:
More informationLab Exercise 3: Media, incubation, and aseptic technique
Lab Exercise 3: Media, incubation, and aseptic technique Objectives 1. Compare the different types of media. 2. Describe the different formats of media, plate, tube etc. 3. Explain how to sterilize it,
More informationAdvisory Leaflet Food Sampling A Guide to Microbiological Quality of Food Samples
Environmental Services Directorate Advisory Leaflet Food Sampling A Guide to Microbiological Quality of Food Samples Why do you take food samples? The Food Safety Act 1990 and Regulation (EC) Number 178/2002
More informationWater and Wastewater. Sample Collection and Analysis
Water and Wastewater Sample Collection and Analysis December 2011 Introduction Accurate testing of drinking water is crucial to maintaining the health and safety of Islanders who rely on this resource.
More information3M Food Safety 3M Petrifilm Plates and 3M Petrifilm Plate Reader
3M Food Safety 3M Petrifilm Plates and 3M Petrifilm Plate Reader brilliant. This red dot changed microbiology. Imagine what it can do for your lab. In today s environment of heightened focus on food safety
More informationMICROBIAL HAZARDS. Eating food contaminated with harmful microorganisms. These
MICROBIAL HAZARDS Microorganisms are everywhere. They can be found in the air, in water, in soil, on animals, and even on humans. Some are beneficial, such as those used to make fermented dairy and meat
More informationQuality Assurance Requirements for Food by Prescription
1616 Fort Myer Drive, 12th Floor Arlington, Virginia 22209-3100 USA www.scms.pfscm.org Telephone: +1.571.227.8600 Fax: +1.571.227.8601 Quality Assurance Requirements for Food by Prescription Background
More informationProficiency testing for food and water microbiology
Proficiency testing for food and water microbiology 1 Proficiency testing for food and water microbiology Public Health England Public Health England (PHE) is an executive agency of the United Kingdom
More informationMicrobiological Testing of the Sawyer Mini Filter. 16 December 2013. Summary
Microbiological Testing of the Sawyer Mini Filter 16 December 2013 Summary The Sawyer Mini Filter was tested for its ability to remove three microorganisms Raoultella terrigena, Bacillus subtilis, and
More information3M Petrifilm Plate Certificates, Recognitions and Validations 3M Food Safety is certified to ISO-9001 for design and manufacturing
International Recognition v AFNOR All foods Aerobic Count Plates NF Validation Certificate Number 3M 01/1-09/89 (as compared to ISO 4833 method) All foods (except raw shellfish) All foods All foods (except
More informationInterplay between food safety climate, food safety management system and microbiological hygiene and safety
Interplay between food safety climate, food safety management system and microbiological hygiene and safety Illustrated in farm butcheries and affiliated butcher shops ir. Elien De Boeck Elien.DeBoeck@Ugent.be
More informationOne Detection Technology. Three Applications. One Automated Platform.
One Detection Technology. Three Applications. One Automated Platform. Proven Technology in Use at FDA Regulated Sites The Growth Direct System revolutionizes microbial testing for quality control in the
More informationEverything you want to know about USP 797
Everything you want to know about USP 797 Dr. Linda D. Lee Director of Operations Waste Management Healthcare Solutions September. 22, 2009 Goals High level understanding of USP 797 Who does it apply too
More informationHygiene Standards for all Food Businesses
Hygiene Standards for all Food Businesses Food hygiene laws are not simply a list of rules. They are intended to let food business operators assess the risks to food safety in their business and apply
More informationUltra Violet Disinfection 01422 833121 info@springhillwaterservices.co.uk
info@springhillwaterservices.co.uk Applications Overview Ultraviolet (UV) disinfection is used to treat three billion litres of water every day around the world as it is a highly effective treatment method
More informationLaboratory for Food Microbiology and Food Preservation (LFMFP) Devlieghere F., Uyttendaele M & Debevere J.
Laboratory for Food Microbiology and Food Preservation (LFMFP) Devlieghere F., Uyttendaele M & Debevere J. Department of Food Safety and Food Quality Faculty of Bio-science engineering Ghent University
More informationCurrent methods: late results (2 to 3 days) contamination spread in the distribution system water consumed
ATP measurements for online monitoring of microbial drinking quality - evaluating potential Óluva K. Vang Measuring microbial drinking quality today? Current methods: late results (2 to 3 days) contamination
More informationTECHNICAL REPORT on the disinfection systems in dental unit water lines.
TECHNICAL REPORT on the disinfection systems in dental unit water lines. Part I. Microbiological field tests Purpose: checking the hygienic quality of the water delivered by a Cefla Dental Group dental
More informationHygiene Assessment of the Performance of Food Safety Management System Implemented by Abattoirs in Edo State, Nigeria
Full-text Available Online at J OURNAL OF A PPLIED S CIENCE AND E NVIRONMENTAL M ANAGEMENT. JASEM ISSN 1119-8362 All rights reserved www.ajol.info and www.bioline.org.br/ja J. Appl. Sci. Environ. Manage.
More informationFoodBioTimerAssay: a new microbiological biosensor for detection of Escherichia coli food contamination
IJPH - Year 6, Volume 5, Number 3, 2008 FoodBioTimerAssay: a new microbiological biosensor for detection of Escherichia coli food contamination Francesca Berlutti 1, Fabrizio Pantanella 1, Maria De Giusti
More informationGeneral food hygiene rules
General food hygiene rules Why food hygiene is important? Good food hygiene is essential to ensure that the food you and your family eats is safe. Poor hygiene procedures in your home can put you at risk.
More informationTesting Surface Disinfectants
Testing Surface Disinfectants This series of knowledge sharing articles is a project of the Standardized Biofilm Methods Laboratory in the CBE KSA-SM-06 Enumerating viable cells by pooling counts for several
More informationDOMESTIC WASTEWATER SYSTEMS
Environmental PROTECTION Systems DOMESTIC WASTEWATER SYSTEMS Highest quality sewage treatment systems from the name you can trust Hynds Aerated Wastewater Systems Hynds Lifestyle Systems are an elite range
More informationAgenda. Environmental Monitoring for Pathogen Control Verification 4/6/2015. Introduction. Today s goals
Agenda Environmental Monitoring for Pathogen Control Verification Warren E. Stone, MBA Grocery Manufacturers Association Safe Food California Monterey, CA April 8, 2015 1. Intro 2. Risk Evaluation 3. Monitoring
More informationOverview. Objective. Purpose. Hypothesis. Procedure
Detection of Indoor borne Fungal Contamination Through Examination of Building Heating, Ventilating and Conditioning (HVAC) s Hernando Perez, PhD, MPH Assistant Professor Department of Environmental and
More informationRaw Milk Quality Tests Do They Predict Fluid Milk Shelf-life or Is it time for new tests?
Raw Milk Quality Tests Do They Predict Fluid Milk Shelf-life or Is it time for new tests? Martin Wiedmann Milk Quality Improvement Program November 3, 2011 Fluid milk shelf life What defines shelf life
More informationExpert Opinion. on the efficacy of. EndoDet and EndoDis + EndoAct. for cleaning and disinfection of. Olympus Gastroscope Type GIF-2T200.
Expert Opinion on the efficacy of EndoDet and EndoDis + EndoAct for cleaning and disinfection of Olympus Gastroscope Type GIF-2T200 with the Endo Thermo Disinfector ETD3 tested according to the recommendations
More informationCLOTHING TO PROTECT AGAINST INFECTION
CLOTHING TO PROTECT AGAINST INFECTION Photo: EU Humanitarian Aid and Civil Protection Strict medical control and the protection of those who come into contact with biological agents are fundamental to
More informationSampling of the surface contamination using sterile cotton swabs from toys obtained from
RESULTS Sampling of the surface contamination using sterile cotton swabs from toys obtained from the Nursery at Queen Mary, University of London showed diverse microorganism growth. A variety of species
More informationSalmonella spp. Quality Assurance in low moisture foods. Control of the Enterobacteriaceae family and
Quality Assurance in low moisture foods. Control of the Enterobacteriaceae family and Salmonella spp Quality Assurance for RUTF & RUSF Supplier Meeting Jean-Louis Cordier Founded in 1962 through International
More informationMICROBIOLOGICAL RISK ASSESSMENT OF ICE-CREAM
Risk Assessment Studies Report No. 7 MICROBIOLOGICAL RISK ASSESSMENT OF ICE-CREAM SEPTEMBER 2001 Food and Environmental Hygiene Department HKSAR 1 This is a publication of the Food and Public Health Branch
More informationIntroduction. Introduction. Why do we need microbiological diagnostics of udder infections? Microbiological diagnostics How is it done?
Introduction Microbiological diagnostics of udder infections Karin Persson Waller National Veterinary Institute (SVA) Swedish University of Agricultural Sciences Uppsala, Sweden Mastitis = in most cases
More informationLAB 4. Cultivation of Bacteria INTRODUCTION
LAB 4. Cultivation of Bacteria Protocols for use of cultivation of bacteria, use of general growth, enriched, selective and differential media, plate pouring, determination of temperature range for growth
More informationUTILIZATION of PLASMA ACTIVATED WATER in Biotechnology, Pharmacology and Medicine. JSC TECHNOSYSTEM-ECO Moscow, Russia April, 2009
UTILIZATION of PLASMA ACTIVATED WATER in Biotechnology, Pharmacology and Medicine JSC TECHNOSYSTEM-ECO Moscow, Russia April, 2009 METHOD of WATER ACTIVATION with PLASMA of GAS DISCHARGE ANODE VACUUM WATER
More informationAnnex to the Accreditation Certificate D-PL-14085-01-00 according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH German Accreditation Body Annex to the Accreditation Certificate D-PL-14085-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 14.09.2010 to 13.09.2015
More informationTHE DAIRY PRACTICES COUNCIL GUIDELINES FOR CLEAN ROOM TECHNOLOGY
THE DAIRY PRACTICES COUNCIL 14 GUIDELINES FOR CLEAN ROOM TECHNOLOGY Publication: DPC 14 Single Copy: $ 3.00 January 1994 Prepared by PLANT EQUIPMENT & PROCEDURES TASK FORCE Elizabeth Jedrziewski, Subcommittee
More informationRisk-Based Environmental Monitoring. Marsha Stabler Hardiman Senior Consultant Concordia ValSource Wednesday September 17, 2014 FDA/PQRI
Risk-Based Environmental Monitoring Marsha Stabler Hardiman Senior Consultant Concordia ValSource Wednesday September 17, 2014 FDA/PQRI Presenter Marsha Stabler Hardiman Over 20 years experience in the
More informationSimple and Effective System for Colony Counting. Finally, You Have a Choice! Online Ordering Available 041614ss
Simple and Effective System for Colony Counting Finally, You Have a Choice! Online Ordering Available 041614ss Compact Dry is a ready-to-use system reducing the time needed to perform microbial testing
More informationASTCCR2 - SQA Unit Code H548 04 Carry out and complete clean-room cleaning operations
Carry out and complete clean-room cleaning Overview 1 Carry out clean-room 2 Remove and store equipment, tools and materials after clean-room 3 Remove and dispose of contaminated material after clean-room
More informationABSTRACT. CFU/ml in case of air water syringe, 6.181 log 10 CFU/ml in case of high speed air turbine hand-piece and 2.828 log 10
Original Research Waterline contamination and role of flushing dental water unit lines in private dental clinics of Mangalore ROSHAN SHETTY*# B. SURESHCHANDRA**## VIJAYA HEGDE***# ABSTRACT Aim: To determine
More informationFMI Listeria Action Plan for Retail Delis
FMI Listeria Action Plan for Retail Delis November 2012 Listeria control at retail is an ongoing challenge. FMI and our members are committed to finding ways to control the growth and if possible, eliminate
More informationCleanroom. For. Sterile Manufacturing Facilities
Cleanroom For Sterile Manufacturing Facilities Praphon Angtrakool Food and Drug Administration 1 WHO TRS No. 823 Annex 1, 1992 (1) General 17.1 The production of sterile preparations should be carried
More informationIsolation and Identification of Bacteria Present in the Activated Sludge Unit, in the Treatment of Industrial Waste Water
Iranian J. Publ. Health, Vol. 30, Nos. 3-4, PP. 91-94, 2001 Isolation and Identification of Bacteria Present in the Activated Sludge Unit, in the Treatment of Industrial Waste Water MK Sharifi-Yazdi 1,
More informationSUITABILITY OF THE H 2 S METHOD FOR TESTING UNTREATED AND CHLORINATED WATER SUPPLIES
Wat.Sci.Tech.44(6): 9-6 SUITABILITY OF THE H S METHOD FOR TESTING UNTREATED AND CHLORINATED WATER SUPPLIES J NAIR, R GIBBS, K MATHEW, AND G E HO Institute for Environmental Sciences, Murdoch University
More informationGUIDELINES ON TEST METHODS FOR ENVIRONMENTAL MONITORING FOR ASEPTIC DISPENSING FACILITIES
GUIDELINES ON TEST METHODS FOR ENVIRONMENTAL MONITORING FOR ASEPTIC DISPENSING FACILITIES PRODUCED BY A WORKING GROUP OF THE SCOTTISH QUALITY ASSURANCE SPECIALIST INTEREST GROUP SECOND EDITION FEBRUARY
More information`TORAY TEXTILES EUROPE
`TORAY TEXTILES EUROPE See It Safe ANTI-MICROBIAL TEST RESULTS October 2006 Antimicrobial Test Methods Used ' TORAY' AATCC 147 (Modified) Antibacterial Activity Assessment of Tetile Materials: Parallel
More informationURINE CULTURES GENERAL PROCEDURE
University of Nebraska Medical Center Division of Laboratory Science Clinical Laboratory Science Program CLS 418/CLS 419 URINE CULTURES GENERAL PROCEDURE I. Principle Urine cultures are performed to detect
More informationFacility Cleaning & Monitoring. Cleaning
Facility Cleaning & Monitoring Cleaning GTP Regulations: 21CFR Part 1271.190 Maintain facility in clean, sanitary & orderly manner Establish & maintain procedures for facility cleaning Assign responsibility
More informationProduct Code: CP54PB HEAT TREATED GROUND BLACK PEPPER SPECIFICATION.
Product Code: CP54PB HEAT TREATED GROUND BLACK PEPPER SPECIFICATION. 1. Description: Whole Black Peppercorns (Piper nigrum L.) ground into a powder, which has undergone no fumigation or irradiation treatment.
More informationValidating and Monitoring the Cleanroom
6 Validating and Monitoring the Cleanroom Kevina O Donoghue Overview... 6-1 Cleanroom Design... 6-1 Principles of Cleanroom Validation and Testing... 6-2 Cleanroom Validation... 6-2 So How Does One Determine
More informationEnvironmental Monitoring for Listeria in Fresh Produce
Environmental Monitoring for Listeria in Fresh Produce Margaret D. Hardin, Ph.D. Vice President Technical Services IEH Laboratories & Consulting Group Lake Forest Park, WA June 9, 2015 Sampling & Testing
More informationDisc Diffusion Susceptibility Methods
Disc Diffusion Susceptibility Methods Introduction When a filter paper disc impregnated with a chemical is placed on agar the chemical will diffuse from the disc into the agar. This diffusion will place
More informationBenchmarking Good Manufacturing Practices
Parker Hannifin Corporation Filtration and Separation Division 242 Neck Road Haverhill, MA 01835 phone: 800 343 4048 or 978 858 0505 fax: 978 556 7501 http://www.parker.com/balston Reducing Contamination
More informationBD Modified CNA Agar BD Modified CNA Agar with Crystal Violet
INSTRUCTIONS FOR USE READY-TO-USE PLATED MEDIA PA-255082.02 Rev.: June 2003 BD Modified CNA Agar BD Modified CNA Agar with Crystal Violet INTENDED USE BD Modified CNA Agar is a selective medium for the
More informationMICROBIOLOGICAL REFERENCE CRITERIA FOR FOOD. October 1995
MICROBIOLOGICAL REFERENCE CRITERIA FOR FOOD October 1995 Acknowledgments The Food Administration section of the Ministry of Health wishes to thank the Institute of Environmental Science and Research Ltd
More informationHow To Make High Energy Biscuits
Technical Specifications of: High Energy Biscuits -HEB Specification reference: HEB Version: 13.0 Date of issue: 25 February 2013 Developed: Van Hoan NGUYEN, OSPFQ-WFP Reviewed: Shane PRIGGE, OSPFQ-WFP;
More information