1 Accessible Single Occupancy Toilet Rooms s Chapter 11 - Accessibility Connecticut State Building Code 1999 Section The drawings on the following pages have been reproduced from handouts from the State Building Inspector's Office. They are intended to illustrate specific code requirements and shall not be interpreted as the actual State Building Code. These illustrations shall not be scaled nor used as part of any submission to the Division of Building Inspection for the purpose of obtaining a permit.

2 on the width of lavatory 15" 5'-0" on type of water closet 12" 48" depending on type of water closet NOTE: 12" door maneuvering clearance on push side when both latch and door closer are provided. Drawings are for illustrative purposes only. Do not scale or submit as plans for permit. 2

3 on the width of lavatory 15" 5'-0" on type of water closet 24" x 6'-8" 3'-0" 5'-0" depending on type of water closet NOTE: When the door swings into the of any fixture, in a single occupant toilet room, a 30" x 48" shall be provided within the room beyond the arc of the door. (ICC/ANSI, section exception) 3

4 5'-0" 15" on the width of lavatory depending on of lav., plus door framing and jamb. 12" 3'-0" door 48" Door framing plus door jamb NOTE: 12" door maneuvering clearance on push side when both latch and door closer are provided. 4

5 5'-0" 15" on the width of lavatory depending on of lav., plus door framing and jamb. 24" 3'-0" door 5'-0" Door framing plus door jamb NOTE: 24" wall clearance on pull side of door minimum NOTE: When the door swings into the of any fixture, in a single occupant toilet room, a 30" x 48" shall be provided within the room beyond the arc of the door. (ICC/ANSI, section exception) 5

6 5'-0" water closet Water closet depending on of water closet & lavatory. 5'-0" door maneuvering clearance 24" 15" 3'-0" door on the width of lavatory NOTE: 24" wall clearance on pull side of door minimum NOTE: When the door swings into the of any fixture, in a single occupant toilet room, a 30" x 48" shall be provided within the room beyond the arc of the door. (ICC/ANSI, section exception) 6

7 5'-0" water closet depending on of water closet & lavatory. 48" door maneuvering clearance Water closet 12" 15" NOTE: 12" door maneuvering clearance on push side when both latch and door closer are provided. 7

8 5'-0" water closet depending on of water closet & lavatory. 48" lavatory Water closet 5'-0" door maneuvering clearance may vary depending on knee and toe clearance availability. 15" Lav. width varies 24" depending on width of lavatory, plus door framing and jamb. Door framing plus door jamb NOTE: 24" wall clearance on pull side of door minimum NOTE: When the door swings into the of any fixture, in a single occupant toilet room, a 30" x 48" shall be provided within the room beyond the arc of the door. (ICC/ANSI, section exception) 8

9 5'-0" water closet depending on of water closet & lavatory. 48" lavatory Water closet 48" door maneuvering clearance may vary depending on knee and toe clearance availability. 15" Lav. width varies 12" Door framing plus door jamb depending on width of lavatory, plus door framing and jamb. NOTE: 12" door maneuvering clearance on push side when both latch and door closer are provided. 9

10 depending on of the lavatory. 4'-8" water closet depending on width of the lavatory. 15" Lav. width varies 5'-0" water closet 48" door maneuvering clearance 12" NOTE: 12" door maneuvering clearance on push side when both latch and door closer are provided. 10

11 5'-0" Lav. width varies 15" 12" 48" depending on of lavatory. NOTE: 12" door maneuvering clearance on push side when both latch and door closer are provided. 11

604 Water Closets and Toilet Compartments

604 Water Closets and Toilet Compartments 604 Water Closets and Toilet Compartments 604.1 General. Accessible water closets and toilet compartments shall comply with Section 604. 604.2 Location. The water closet shall be positioned with a wall

More information

ADA Design Guide Washrooms & Showers

ADA Design Guide Washrooms & Showers ADA Design Guide Washrooms & Showers Accessories Faucets Showers Toilets Lavatories interactive version available at bradleycorp.com/adaguide.pdf Accessible Stall Design There are many dimensions to consider

More information

City of Riverside Building & Safety Division Phone: (951) 826-5697 www.riversideca.gov

City of Riverside Building & Safety Division Phone: (951) 826-5697 www.riversideca.gov City of Riverside Building & Safety Division Phone: (951) 826-5697 www.riversideca.gov BUILDING CODE REQUIREMENTS FOR CHILD DAY CARE The purpose of this document is to provide the user with a basic level

More information

Land Use and Environmental Service Agency (Code Enforcement) NC Plumbing Code. Table of Contents

Land Use and Environmental Service Agency (Code Enforcement) NC Plumbing Code. Table of Contents Chapter 1 Administration Chapter 3 General Regulations Chapter 5 Water Heaters Chapter 7 Sanitary Drainage Chapter 9 Vents Chapter 11 Storm Drainage Policy Statements Table of Contents Chapter 2 Definitions

More information

California Building Code Effective January 2014 HOUSING ACCESSIBILITY ACCESSIBLE WATER CLOSETS Title 24, Part 2 1127A

California Building Code Effective January 2014 HOUSING ACCESSIBILITY ACCESSIBLE WATER CLOSETS Title 24, Part 2 1127A The following are summarized excerpts from some of the new building codes for these accessible bathroom fixtures. Please refer to the 2013 California Building Code books for more details and drawings.

More information

Significant Changes to the 2013 California Building Code Chapter 11B accessibility standards

Significant Changes to the 2013 California Building Code Chapter 11B accessibility standards Significant Changes to the 2013 California Building Code Chapter 11B accessibility standards Last updated: 4/8/13 The Division of State Architect s (DSA) office has recently posted the Final Approved Express

More information

Bath Planning Guidelines With Access Standards

Bath Planning Guidelines With Access Standards Bath Planning Guidelines With s 1: Door/Entry The clear opening of a doorway should be at least 32. This would require a minimum 2-10 door. If the existing structure precludes changing the opening then

More information

Universal Design Recommendations for Accessible University Settings. Mauricio A. Lizama, Ph.D., ATP

Universal Design Recommendations for Accessible University Settings. Mauricio A. Lizama, Ph.D., ATP INFORME TÉCNICO Unidad de Diseño, Desarrollo y Evaluación de AT PRATP Septiembre, 2009 Universal Design Recommendations for Accessible University Settings Mauricio A. Lizama, Ph.D., ATP The features listed

More information

Welcome to the AccessibilityOnline Webinar Series. A collaborative program between the National Network of ADA Centers and the. U.S.

Welcome to the AccessibilityOnline Webinar Series. A collaborative program between the National Network of ADA Centers and the. U.S. Welcome to the AccessibilityOnline Webinar Series A collaborative program between the National Network of ADA Centers and the US Access Board The Session is Scheduled to begin at 2:30pm Eastern Time We

More information

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS DCD-0304 Identification # Rev. 9/08 County Date of Inspection NAME OF OPERATION BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS ADDRESS TELEPHONE: CITY STATE ZIP BUILDING INSPECTORS CERTIFICATE

More information

Lori Greene, AHC/CDC, CCPR, FDAI

Lori Greene, AHC/CDC, CCPR, FDAI Lori Greene, AHC/CDC, CCPR, FDAI Manager, Codes & Resources 25+ years in the industry 20 years with Allegion and Ingersoll Rand Security Technologies Previous Positions Specification Team Leader New England

More information

U.S. DEPARTMENT OF HOUSING & URBAN DEVELOPMENT OFFICE OF FAIR HOUSING & EQUAL OPPORTUNITY UFAS ACCESSIBILITY CHECKLIST

U.S. DEPARTMENT OF HOUSING & URBAN DEVELOPMENT OFFICE OF FAIR HOUSING & EQUAL OPPORTUNITY UFAS ACCESSIBILITY CHECKLIST Facility Name Name of Reviewer(s) Address Date(s) of Review Unit/Apartment Number Date Building was Built Telephone Number Date(s) of Renovations, if any TDD/TTY Number (Any structure built after July

More information

Common ADA Errors and Omissions in New Construction and Alterations

Common ADA Errors and Omissions in New Construction and Alterations U.S. Department of Justice Civil Rights Division Disability Rights Section Common ADA Errors and Omissions in New Construction and Alterations Introduction The ADA requires that new construction and alterations

More information

REQUIREMENT 3. Usable Doors

REQUIREMENT 3. Usable Doors Chapter Three: REQUIREMENT 3 Usable Doors 3...covered multifamily dwellings with a building entrance on an accessible route shall be designed in such a manner that all the doors designed to allow passage

More information

HEALTH FACILITY CHECKLIST SECTION 1226 [OSHPD 3] CLINICS 1226.6 PRIMARY CARE CLINICS

HEALTH FACILITY CHECKLIST SECTION 1226 [OSHPD 3] CLINICS 1226.6 PRIMARY CARE CLINICS Compliance Checklist: [OSHPD 3] Primary Care Clinics Page 1 of 7 HEALTH FACILITY CHECKLIST SECTION 1226 [OSHPD 3] CLINICS 1226.6 PRIMARY CARE CLINICS Primary Care Clinics are Health Facilities licensed

More information

Borges Construction Company A limited liability Corporation Page1 of 1

Borges Construction Company A limited liability Corporation Page1 of 1 Page1 of 1 The following is a quote to remodel the master bathroom at your home: Materials Labor Demolition 1 Dumpster $ 225.00 $ - 2 Remove existing carpet $ - $ 50.00 3 Remove existing tile $ - $ 80.00

More information

American Academy of Physical Medicine and Rehabilitation Site Survey Report

American Academy of Physical Medicine and Rehabilitation Site Survey Report American Academy of Physical Medicine and Rehabilitation Site Survey Report Introduction and Background In early 2013, the Contract Meeting Manager for the American Academy of Physical Medicine and Rehabilitation

More information

Calvert USA, Inc. Attic Stairs

Calvert USA, Inc. Attic Stairs Calvert USA, Inc. Attic Stairs Instructions for installation of vertical opening access stairs Model numbers: 7035 through 7047 Calvert USA, Inc., P.O. Box 841, Solomons, MD 20688, Tel. (410) 286-1430,

More information

city of edmonds development information

city of edmonds development information #B17 city of edmonds development information Commercial Kitchen Hood & Hood Fire Suppression System Permit Submittal Requirements PERMIT REQUIRED: CODES: FEES: A Commercial Kitchen Hood Mechanical Permit

More information

Strategies for Compliant Bathrooms

Strategies for Compliant Bathrooms (888) 341-7781 (V/TTY) - Technical Guidance www.fairhousingfirst.org 2005-2006 Designed and Developed by: The BearingPoint Team for U.S. Dept. of Housing and Urban Development C-OPC-22667 October 2005

More information

HARDWARE LOCATIONS FOR HOLLOW METAL DOORS AND FRAMES

HARDWARE LOCATIONS FOR HOLLOW METAL DOORS AND FRAMES HOLLOW METAL MANUAL NAAMM STANDARD HMMA 831-11 8d NAAMM HMMA 831-11 METAL DOORS & FRAMES HARDWARE LOCATIONS FOR HOLLOW METAL DOORS AND FRAMES 8d NAAMM HMMA 831-11 METAL DOORS & FRAMES A Division of HOLLOW

More information

The emergency provisions affect the following Building Code sections:

The emergency provisions affect the following Building Code sections: On August 1, 2012 new emergency chapter 11B code provisions became effective. Attached are copies of the emergency express terms and the applicable figures. The new requirements are underlined and deleted

More information

Kitchen Planning Guidelines With Access Standards

Kitchen Planning Guidelines With Access Standards Kitchen Planning Guidelines With s 1: Door/Entry The clear opening of a doorway should be at least 32 wide. This would require a minimum 2-10 door. The clear opening of a doorway should be at least 34.

More information

BUILDING PERMIT SPECIFICATIONS

BUILDING PERMIT SPECIFICATIONS BUILDING PERMIT SPECIFICATIONS The below noted requirements are based upon La Plata County Building Code. These specifications are not intended as a complete set of requirements, but are intended to provide

More information

Home Warranty Inspection Report

Home Warranty Inspection Report Scope of the Inspection 1111 Sample Dr. home warranty inspection 2/30/2006 Home Warranty Inspection Report 1111 Sample Dr., Detroit, MI 48223 Inspection Date: February 30, 2006 Client: Alfred E. Neumann

More information

Common ADA Errors and Omissions in New Construction and Alterations

Common ADA Errors and Omissions in New Construction and Alterations Common ADA Errors and Omissions in New Construction and Alterations Learning Objectives Course Number: 6002 Credit Hours: 1 After completing this course you will have a better understanding of numerous

More information

Inspection Item COMMENTS

Inspection Item COMMENTS APPENDIX 9 AFFORDABLE HOUSING PROGRAM INSPECTION CHECKLIST Participating Jurisdiction: Homeowner Name: Assisted Property Address: Date of Physical Inspection of Property: Total Square Footage of Property:

More information

White Paper FIRE DOOR INSPECTIONS, REPAIRS AND LABELING

White Paper FIRE DOOR INSPECTIONS, REPAIRS AND LABELING INTRODUCTION When the 2012 edition of the Life Safety Code is adopted by the Centers for Medicare Services (CMS) the following accreditation organizations The Joint Commission, AOA Healthcare Facilities

More information

Technical Bulletin: Understanding the ADA and Implications for Office Design

Technical Bulletin: Understanding the ADA and Implications for Office Design Technical Bulletin: Understanding the ADA and Implications for Office Design What is the ADA? The Americans with Disabilities Act (ADA) is a federal law enacted in 1990. It prohibits discrimination on

More information

Chapter Seven: REQUIREMENT 7. Usable Kitchens and Bathrooms PART A: Usable Kitchens PART B: Usable Bathrooms

Chapter Seven: REQUIREMENT 7. Usable Kitchens and Bathrooms PART A: Usable Kitchens PART B: Usable Bathrooms Chapter Seven: REQUIREMENT 7 Usable Kitchens and Bathrooms PART A: Usable Kitchens PART B: Usable Bathrooms 7 PART A: Usable Kitchens 7a...covered multifamily dwellings with a building entrance on an accessible

More information

ANSI A250.4 Test Procedure and Acceptance Criteria for Physical Endurance for Steel Doors, Frames and Frame Anchors

ANSI A250.4 Test Procedure and Acceptance Criteria for Physical Endurance for Steel Doors, Frames and Frame Anchors ANSI A250.4 Test Procedure and Acceptance Criteria for Physical Endurance for Steel Doors, Frames and Frame Anchors 1 Learning Session Description This training aid focuses on the revisions to ANSI A250.4-2011

More information

New York City Department of Buildings

New York City Department of Buildings The New NYC Building Code Chapter 11 Accessibility New York City Department of Buildings Technical Affairs Keith Wen, R.A. Copyright Materials This presentation is protected by US and International Copyright

More information

Classroom Door Security & Locking Hardware

Classroom Door Security & Locking Hardware Classroom Door Security & Locking Hardware The ability to protect students and teachers while in the classroom is a high priority in all educational institutions. Many schools and school districts have

More information

Isometric Plumbing Drawings

Isometric Plumbing Drawings Building Inspections Isometric Plumbing Drawings All commercial building permit applications, in which the plumbing system has not been designed by a mechanical engineer, must include two sets of isometric

More information

Hinge Replacement & Hinge and Hardware Adjustment Guide for Andersen Frenchwood Hinged Patio Doors Manufactured Before November 2005

Hinge Replacement & Hinge and Hardware Adjustment Guide for Andersen Frenchwood Hinged Patio Doors Manufactured Before November 2005 Hinge Replacement & Hinge and Hardware Adjustment Guide for Andersen Frenchwood Hinged Patio Doors Manufactured Before November 2005 For ease of installation and continued enjoyment of your Andersen product,

More information

HMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES

HMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES HOLLOW METAL MANUAL NAAMM STANDARD HMMA 810-87 8d METAL DOORS & FRAMES NAAMM 2 87 HOLLOW METAL HOLLOW METAL DOORS FOURTH EDITION NAAMM 2 87 8d METAL DOORS & FRAMES A Division of NATIONAL ASSOCIATION OF

More information

Foundation Evaluation Report for PROPERTY ADDRESS Houston, Texas 77089. August 30, 2012. Prepared for:

Foundation Evaluation Report for PROPERTY ADDRESS Houston, Texas 77089. August 30, 2012. Prepared for: A Full Service Real Estate Inspection & Engineering Firm for Houston, Texas 77089 August 30, 2012 Prepared for: CLIENT S NAME MAILING ADDRESS Houston, Texas 77089 Prepared by: Charles J. Jenkins, P.E.

More information

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN 46787 Phone (260) 723-5131 Sales Fax (260) 723-6396 whitley@whitleyman.

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN 46787 Phone (260) 723-5131 Sales Fax (260) 723-6396 whitley@whitleyman. Building Type Building Code Whitley Classroom Buildings BOCA, UBC, SBCCI, NEC, ADA Structural Support Outrigger construction standard, Whitley model classrooms. Main support beams to be 12 11.8# per lineal

More information

Hinge, Blocker, and Tab Adjustment Guide

Hinge, Blocker, and Tab Adjustment Guide Hinge, Blocker, and Guide for Andersen A-Series Hinged Outswing; 400 Series Frenchwood Hinged Outswing Patio Doors and 400 Series Frenchwood Hinged Outswing Patio Doors with Stormwatch Protection Hinge,

More information

WHEDA. 2016 LIHTC Self Scoring Exhibit

WHEDA. 2016 LIHTC Self Scoring Exhibit WHEDA 2016 LIHTC Self Scoring Exhibit Calculate Applicant Scores for your development on this Exhibit. You must proactively choose or decline participation in each scoring category. Points will not be

More information

Property Maintenance Check List

Property Maintenance Check List Property Maintenance Check List Scope These minimum conditions and responsibilities of persons for maintenance of structures, equipment and exterior property shall govern. Responsibility. Owners shall

More information

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

WHI 90-Minute Rated Veneered Door Frame Installation Instructions No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,

More information

6' 7-1/2" SIZE TABLES Aluminum-Clad Exterior

6' 7-1/2 SIZE TABLES Aluminum-Clad Exterior 6' 7-1/2" SIZE TABLES 2' 7 1/ 2" (800) 3' 1 1/ 2" 2' 6 3 / 4" (781) 3' 0 3 / 4" (953) 4' 1 1/ 2" (1 257) (933) 4' 0 3 / 4" (1 238) 3180 3780 4980 5' 0" 4' 11 (1 524) 6' 0" (1 505) 5' 11 (1 829) 8' 0" (2

More information

New Ontario Building Code Highlights

New Ontario Building Code Highlights New Ontario Building Code Highlights Part 9 This summary highlights items that are believed to be significant changes to the 2012 OBC and is not intended to include all changes made within this or other

More information

Glass. Pre-Assembled Glass Entry Doors. In Stock Models Available! 1-800-486-8415

Glass. Pre-Assembled Glass Entry Doors. In Stock Models Available! 1-800-486-8415 Glass Store Front Doors 1-800-486-8415 www.glassstorefrontdoors.com Pre-Assembled Glass Entry Doors Commercial Glass Store Front Doors Pre-Assembled and Ready for Quick Install In Stock Models Available!

More information

for Phoenix II-2 Human Cremation Retort

for Phoenix II-2 Human Cremation Retort Installation Manual for Phoenix II-2 Human Cremation Retort Please Read Carefully Before Installing. Any Questions? Please Call! Failure to install properly may VOID your warranty. NOTICE: Specifications

More information

Name Of Occupancy Date. Yes No Describe

Name Of Occupancy Date. Yes No Describe FIRE PREVENTION INSPECTION CHECKLIST For Class A Occupancy (For Assembly Buildings, Bars, Restaurants, Gyms, Churches, Arenas, Theatres or wherever people gather) Name Of Occupancy Date Physical Address

More information

Seattle Tacoma International Airport Restroom Standards

Seattle Tacoma International Airport Restroom Standards Seattle Tacoma International Airport Restroom Standards Last Updated July 10, 2015 Contents Introduction... 2 General Restroom Features:... 2 Mock up During Design... 2 Doorless Entry... 2 Entry Identification

More information

9300BC SERIES Light Commercial Door Closer

9300BC SERIES Light Commercial Door Closer Light Commercial Door Closer general information The 9300BC is a durable, economically priced door closer designed for commercial exterior and interior doors such as storefront and industrial applications.

More information

SECURITY VS. EXITING... Door Locking Hardware in Schools DIVISION OF THE STATE ARCHITECT

SECURITY VS. EXITING... Door Locking Hardware in Schools DIVISION OF THE STATE ARCHITECT SECURITY VS. EXITING... Door Locking Hardware in Schools DIVISION OF THE STATE ARCHITECT G U I D E L I N E S DSA Guidelines for Door Locking Hardware in Schools Egress doors shall be readily openable from

More information

Expanding Your Market

Expanding Your Market U.S. Department of Justice Civil Rights Division Disability Rights Section Expanding Your Market Maintaining Accessible Features in Retail Establishments Introduction More than 50 million Americans with

More information

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances. Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org

More information

There is a jam at Tray 1 (MPT). Follow these steps to clear the jam. 1. Remove paper from Tray 1 (MPT).

There is a jam at Tray 1 (MPT). Follow these steps to clear the jam. 1. Remove paper from Tray 1 (MPT). Paper Jams This topic includes: "Jam at Tray 1 (MPT)" on page 4-3 "Jam at Tray 2" on page 4-6 "Jam at Tray 3, 4, or 5" on page 4-8 "Jam at the Fuser" on page 4-11 "Jam at the Duplex Unit" on page 4-14

More information

ADA. Checklist for Readily Achievable Barrier Removal. The Americans with Disabilities Act. Checklist for Existing Facilities version 2.1.

ADA. Checklist for Readily Achievable Barrier Removal. The Americans with Disabilities Act. Checklist for Existing Facilities version 2.1. Checklist for Existing Facilities version 2.1 ADA T I IT L TE S L I EI & I I II I COMPLIANCE MATERIALS To obtain additional copies of this checklist, contact your Disability and Business Technical Assistance

More information

SECURITY LATCH TM SIMPLE, SAFE & SECURE

SECURITY LATCH TM SIMPLE, SAFE & SECURE SECURITY LATCH TM SIMPLE, SAFE & SECURE WHAT IS SECURITY LATCH Security Latch is a simple, safe and secure method used to add extra security to your panic doors. Security Latch is designed to increase

More information

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for premium composite, hollow and solid core molded Bifold Doors. Bifolds are designed for fast

More information

PUBLIC RESTROOMS, DESIGN INTENT

PUBLIC RESTROOMS, DESIGN INTENT PUBLIC RESTROOMS, DESIGN INTENT 1.01 STRUCTURAL A. Where feasible, metal stud partitions will be constructed on a 6 high concrete curb. 1.02 MECHANICAL A. Restrooms will have a minimum of 15 air changes

More information

Your Basement Remodeling Specialist LLC

Your Basement Remodeling Specialist LLC Your Basement Remodeling Specialist LLC Contents Introduction 3 Remodel Details 4 Basement Bid Scope 5 Financial Arrangements 6 Homeowners Shopping Guide 7 The following is provided with your actual quote:

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS door frames Engineered product systems INSTALLATION INSTRUCTIONS door frames MINIMALIST DOOR FRAME Fry Reglet Flush Door frames are designed for use with 3 5/8 studs with ½ drywall both sides (4 5/8 throat

More information

Specialty Closers. High-End Residential High-End Security Gate Solutions

Specialty Closers. High-End Residential High-End Security Gate Solutions Specialty Closers High-End Residential High-End Security Gate Solutions TABLE OF CONTENTS General Information... 3 How to Select Product... 4 Options... 5 Certifications... 6 Limited Warranty... 6 Specifications...

More information

Automatic Door Selection Guide

Automatic Door Selection Guide Automatic Door Selection Guide AAADM 1300 Sumner Avenue Cleveland, OH 44115 P: 216-241-7333 F: 216-241-0105 aaadm@aaadm.com Automatic Door Selection Guide General: The members of AAADM manufacture an assortment

More information

Basic Stretch Programme 3. Exercise Circuit 4

Basic Stretch Programme 3. Exercise Circuit 4 Basic Stretch Programme 3 Exercise Circuit 4 2 1 Calves Stand approximately 1 metre away from wall with legs straight and heels on floor. Step and lean forward and slowly push hips towards wall. Should

More information

City of Los Angeles Department of Building and Safety Disabled Access Section COMMERCIAL ACCESSIBILITY PLAN REVIEW LIST JOB ADDRESS CITY ZIP

City of Los Angeles Department of Building and Safety Disabled Access Section COMMERCIAL ACCESSIBILITY PLAN REVIEW LIST JOB ADDRESS CITY ZIP GENERAL PROJECT INFORMATION PLAN CHECK NO JOB ADDRESS CITY ZIP REVIEWED BY PHONE DATE Email NOTE: Code references are to the 2014 edition of the City of Los Angeles Building Code with July 1, 2015 Supplement

More information

Base Cabinet with Self-storing Folding Doors and Floor

Base Cabinet with Self-storing Folding Doors and Floor Usable Kitchens When designing a kitchen for use by persons with mobility impairments, especially those who use wheelchairs, careful layout of the kitchen is crucial to maintaining accessibility. People

More information

NC Rehab Code Case Study Cheerwine Building January 17, 2002; rev 4/12/02

NC Rehab Code Case Study Cheerwine Building January 17, 2002; rev 4/12/02 NC Rehab Code Case Study Cheerwine Building January 17, 2002; rev 4/12/02 PART A: Project Data and Classification 1. Project name & location Renovation of the Cheerwine Building, 322 East Council St.,

More information

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER: Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER: SECTIONS 1, 2, 3, AND 4 MUST BE COMPLETED BY APPLICANT BEFORE INSPECTION

More information

HMMA 830 HARDWARE SELECTION FOR HOLLOW METAL DOORS AND FRAMES HOLLOW METAL MANUAL -02 NAAMM STANDARD METAL DOORS & FRAMES NAAMM 01 NAAMM 01

HMMA 830 HARDWARE SELECTION FOR HOLLOW METAL DOORS AND FRAMES HOLLOW METAL MANUAL -02 NAAMM STANDARD METAL DOORS & FRAMES NAAMM 01 NAAMM 01 HOLLOW METAL MANUAL NAAMM STANDARD HMMA 830-02 METAL S & FRAMES 8d NAAMM 01 02 HARDWARE SELECTION FOR HOLLOW METAL S AND FRAMES NAAMM 01 02 8d METAL S & FRAMES A Division of HOLLOW METAL MANUFACTURERS

More information

R432. Health, Health Systems Improvement, Licensing. R432-5. Nursing Facility Construction. R432-5-1. Legal Authority. R432-5-2. Purpose.

R432. Health, Health Systems Improvement, Licensing. R432-5. Nursing Facility Construction. R432-5-1. Legal Authority. R432-5-2. Purpose. R432. Health, Health Systems Improvement, Licensing. R432-5. Nursing Facility Construction. R432-5-1. Legal Authority. This rule is promulgated pursuant to Title 26, Chapter 21. R432-5-2. Purpose. The

More information

Installation Instructions and Ordering Information

Installation Instructions and Ordering Information The Flush Finish Trimless Door Frame Installation Instructions and Ordering Information CLEAN LINES! The Flush Finish Door Jamb System Manufactured by STUDCO Building Systems Step 1 Verify if you are using

More information

Applications for building permits will not be reviewed until all of the required information has been submitted.

Applications for building permits will not be reviewed until all of the required information has been submitted. NOTICE: Applications for building permits will not be reviewed until all of the required information has been submitted. Once all items are submitted a minimum of ten (10) working days are required to

More information

CITY OF SHAKER HEIGHTS HOUSING INSPECTION DEPARTMENT 3450 LEE ROAD SHAKER HEIGHTS, OHIO 44120 (216) 491-1470 POINT OF SALE CERTIFICATE OF INSPECTION

CITY OF SHAKER HEIGHTS HOUSING INSPECTION DEPARTMENT 3450 LEE ROAD SHAKER HEIGHTS, OHIO 44120 (216) 491-1470 POINT OF SALE CERTIFICATE OF INSPECTION CITY OF SHAKER HEIGHTS HOUSING INSPECTION DEPARTMENT 3450 LEE ROAD SHAKER HEIGHTS, OHIO 44120 (216) 491-1470 POINT OF SALE CERTIFICATE OF INSPECTION Notice Issued: November 10, 2011 File: 2011-0441 To:

More information

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin americancraftsmanwindows.com Project Requirements: Failure to follow these instructions may void product

More information

Inspection Report of 1895 Jamesport Circle PSL, Fl 33953 Prepared for Yen Ho

Inspection Report of 1895 Jamesport Circle PSL, Fl 33953 Prepared for Yen Ho Inspection Report of 1895 Jamesport Circle PSL, Fl 33953 Prepared for Yen Ho The State of Florida requires the builder to build in compliance with the Florida Building Code. Florida State Statutes 455

More information

The replacement or modification of existing windows shall comply with the following requirements:

The replacement or modification of existing windows shall comply with the following requirements: City of La Habra Heights Building Division 1245 N. Hacienda Road La Habra Heights, CA 90631 Office: (562) 694-6302 ext. 228 Fax: (562) 690-5010 WINDOW REPLACEMENT 2010 CALIFORNIA RESIDENTIAL CODE (CRC)

More information

How To Build A Basement House

How To Build A Basement House Single Family Basement Finish Purpose of Guide The purpose of this guide is to assist you in the permit process for your project. This handout is intended as a basic plan submittal under the 2009 International

More information

SCHOOL FIRE AND LIFE SAFETY INSPECTION CHECKLIST

SCHOOL FIRE AND LIFE SAFETY INSPECTION CHECKLIST SCHOOL FIRE AND LIFE SAFETY INSPECTION CHECKLIST School Name: School Address: Town: Phone: Inspected By (Please Print): Inspection Organization Name: Inspector Phone: Date of Inspection: Building Name:

More information

DIVISION 08 70 00 HARDWARE FORMAT 1. Technical specifications content and numbering system shall be based on 2004 CSI MasterFormat.

DIVISION 08 70 00 HARDWARE FORMAT 1. Technical specifications content and numbering system shall be based on 2004 CSI MasterFormat. FORMAT 1. Technical specifications content and numbering system shall be based on 2004 CSI MasterFormat. BASIS OF DESIGN 1. APSU design standards shall not replace fully developed, project and market specific

More information

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES PRODUCT SELECTION GUIDE SENTRONIC Series LCN closer/holders combine heavy duty closers with electrically controlled hold-open functions to control fire and smoke

More information

Installation Instructions K900 series Door Closer

Installation Instructions K900 series Door Closer Installation Instructions series Non-Hold Open Models Adjustable size : 1(BF) thru 6 Optional Feature : Delayed Action An Incorrectly installed or improperly adjusted door closer can cause property damage

More information

Vestibule Case Study. Vestibule Requirement Intent [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, 90.1-2001, 90.1-2004]

Vestibule Case Study. Vestibule Requirement Intent [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, 90.1-2001, 90.1-2004] Vestibule Case Study [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, 90.1-2001, 90.1-2004] Vestibule Requirement Intent Page 1 of 14 The primary intent behind the requirement for a vestibule is to reduce infiltration

More information

EAST STROUDSBURG BOROUGH RESIDENTIAL RENTAL INSPECTION CHECK LIST

EAST STROUDSBURG BOROUGH RESIDENTIAL RENTAL INSPECTION CHECK LIST DATE TIME EAST STROUDSBURG BOROUGH RESIDENTIAL RENTAL INSPECTION CHECK LIST INSPECTOR: LICENSE # ADDRESS: PROPERTY OWNER: SINGLE: DOUBLE: MULTI-UNIT # OF UNITS POINT OF INSPECTION Sanitation IPMC 302.1

More information

City of Wichita, Kansas Americans with Disabilities Act Transition Plan Main Library Address

City of Wichita, Kansas Americans with Disabilities Act Transition Plan Main Library Address City of Wichita, Kansas Americans with Disabilities Act Transition Plan Main Library Address July 005 Prepared by DMCG Disability Management Consulting Group L.L.C. 801 Jonquil Place Columbia, MO 650 In

More information

PLUMBING FIXTURES. Current with material published in Conn.L.J. through 6/10/08

PLUMBING FIXTURES. Current with material published in Conn.L.J. through 6/10/08 PLUMBING FIXTURES Current with material published in Conn.L.J. through 6/10/08 Sec. 21a-86a-1. Definitions As used in these regulations, the following terms shall, unless the context requires otherwise,

More information

LOCAL LAWS OF THE CITY OF NEW YORK FOR THE YEAR 2013. No. 110

LOCAL LAWS OF THE CITY OF NEW YORK FOR THE YEAR 2013. No. 110 LOCAL LAWS OF THE CITY OF NEW YORK FOR THE YEAR 2013 No. 110 Introduced by Council Members Mendez, Brewer, Chin, James, Lander, Richards, Rose, Rodriguez, Arroyo, and Mark-Viverito. A LOCAL LAW To amend

More information

AVENTOS HF Narrow aluminum door application

AVENTOS HF Narrow aluminum door application AVENTOS HF Narrow aluminum door application Lift mechanism set Lift mechanism (qty ) #7 x 35 mm (-3/8 ) wood screw (qty 0) Power factor 85 30 ( lift mechanism req.) 0F00.N5 3 470 0F00.N5 47 880 0F500.N5

More information

Fabrication Illustration Part No. Description Door Frame. P092 Mortised Butt Hinge P092D P092F (includes P2092 $ 48 $ 21 frame/door reinforcing)

Fabrication Illustration Part No. Description Door Frame. P092 Mortised Butt Hinge P092D P092F (includes P2092 $ 48 $ 21 frame/door reinforcing) Custom Blank Entrances - Applied Hardware & Preps - Tubelite Standard Hardware Butt Hinges Pivots C2 Page 1 P092 Mortised Butt Hinge P092D P092F (includes P2092 $ 48 $ 21 frame/door reinforcing) P795S

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

Fire-Rated Doors and Hardware. A Guide to Field Inspection

Fire-Rated Doors and Hardware. A Guide to Field Inspection Fire-Rated Doors and Hardware A Guide to Field Inspection Foundation s Mission To promote secure and safe openings that enhance life safety Awareness To be a source of information through awareness campaign

More information

Combination Unit (shown from interior) WARNING

Combination Unit (shown from interior) WARNING for Andersen Double-Hung Venting s Windows a i o P t o rs D o Congratulations You have just purchased one of the many fine Andersen products. For ease of assembly and installation and continued enjoyment

More information

Office of the State Fire Marshal. Fire Rated Doors

Office of the State Fire Marshal. Fire Rated Doors Office of the State Fire Marshal Fire Rated Doors Fire Rated Doors These doors serve a purpose. They are manufactured in a way that is to help reduce the spread of fire and smoke. Fire rated doors allow

More information

PROFESSIONAL ENGINEERING INSPECTIONS, INC.

PROFESSIONAL ENGINEERING INSPECTIONS, INC. PROFESSIONAL ENGINEERING INSPECTIONS, INC. P. O. BOX 271492 HOUSTON, TEXAS 77277 Registered Engineering Firm #1503 http://www.profengineering.com (713) 664-1264 July 8, 2004 Mr. Simple Samson 2831 Octoberfest

More information

ADA Guide for Small Businesses

ADA Guide for Small Businesses U.S. Small Business Administration Office of Entrepreneurial Development U.S. Department of Justice Civil Rights Division Americans with Disabilities Act ADA Guide for Small Businesses The U.S. Small Business

More information

SQUARE FOOTAGE REQUIREMENTS FOR USE IN DEVELOPING THE LOCAL FACILITIES PLANS AND STATE CAPITAL OUTLAY APPLICATIONS FOR FUNDING

SQUARE FOOTAGE REQUIREMENTS FOR USE IN DEVELOPING THE LOCAL FACILITIES PLANS AND STATE CAPITAL OUTLAY APPLICATIONS FOR FUNDING SQUARE FOOTAGE REQUIREMENTS FOR USE IN DEVELOPING THE LOCAL FACILITIES PLANS AND STATE CAPITAL OUTLAY APPLICATIONS FOR FUNDING GEORGIA DEPARTMENT OF EDUCATION FACILITIES SERVICES UNIT December 8, 2003

More information

City of Elk River BASEMENT Office Use Only

City of Elk River BASEMENT Office Use Only City of Elk River BASEMENT Office Use Only Fire and Building Safety Division (FABS) Building Permit Application Notes Scan Permit Total Date Permit # PID # $ Site Address Suite/Unit Structure Type Single

More information

1250 & 1450 SERIES SURFACE MOUNTED CLOSERS

1250 & 1450 SERIES SURFACE MOUNTED CLOSERS 1250 & 1450 SERIES SURFACE MOUNTED OSERS PRODUCT SELECTION GUIDE Surface mounted 1250 & 1450 Series LCN closers feature a modern slim line design for easy installation on narrow head frames and top rails.

More information

RRIO Checklist. Use of checklist: Definitions: Limitations

RRIO Checklist. Use of checklist: Definitions: Limitations CITY OF SEATTLE RENTAL REGISTRATION AND INSPECTION ORDINANCE (RRIO) RRIO Checklist Use of checklist: Property owners will use the RRIO Checklist to confirm that their rental housing properties and units

More information

City of St. Charles Basement Finish or Remodel

City of St. Charles Basement Finish or Remodel City of St. Charles Basement Finish or Remodel Building & Code Enforcement Division 2 East Main Street St. Charles IL 60174 630.377.4406 (Office) 630.443.4638 (Fax) http://www.stcharlesil.gov Please direct

More information

AUTOMATIC SWINGING DOOR

AUTOMATIC SWINGING DOOR A Member of AAADM American Association of Automatic Door Manufacturers AUTOMATIC SWINGING DOOR OWNER'S MANUAL Distributed by: Contents Section Page Caution 2 To Our Customers 2 Service Availability 2 Compliance

More information

NIOSH has developed an observational assessment tool for dampness and mold in buildings.

NIOSH has developed an observational assessment tool for dampness and mold in buildings. NIOSH has developed an observational assessment tool for dampness and mold in buildings. GOAL: To provide valuable information for motivating remediation, prioritizing intervention, and evaluating remediation

More information

DuPont Surfaces. DuPont TM Corian Lavatories. TECHNICAL bulletin

DuPont Surfaces. DuPont TM Corian Lavatories. TECHNICAL bulletin DuPont Surfaces DuPont TM Corian Lavatories TECHNICAL bulletin TABLE OF CONTENTS PAGE SECTION 3 Illustration of ADA Guidelines Used 3 Options for Counters Placed 34 from Floor 4 Model 810 with Front Overflow

More information